HomeMy WebLinkAboutProduct Approval HOME IMPROVEMENT CONTRACT
PLEASE READ THIS CONTRACT
ROOFING SPECIFICATION SHEET
DESCRIPTION OF WORK.
Customer Name: Thomas Date: 4n12017
Branch Name: Miami Job#:
Sales Consultant: TREVOR J COHEN
,A
I
Hurricane Mitigation=No,APS,Timberline HD Lifetime,
Shakewood
Number of Squares(excluding Low Slope)=10, Number of
Flat Roof Squares=0 Flashing
Misc Drip Edge=Yes, Linear Ft of Drip Edge to be Installed=
Rigid Ridge Vent=Yes,.Linear Ft Ridge Vent to be 114,Color of Drip Edge to be Installed=White,Chimney
Installed=32,Rigid Ridge Vent-Color=Black,Off Ridge Flashing=Yes,Chimneys Requiring New Flashing= 1,
Vent=No,Replace Fascia=No,Hurricane Mitigation Color of Chimney Flashing to be Installed=White
Inspection=No
Pricing Includes:
Chimney Flashing
Drip Edge-in 10ft Sgmts
Shingle Removal and Application
SPECIAL CONSIDERATIO�+I s x �' ,`�, r
a, q
PRE+ EXISTINI CONDITIONS s
$ $
^(t 7�q (^� i
Nto rr
ADD 'IO �fiiHARGES
41"
If rotted or damaged wood is discovered AFTER removing the existing roofing,or could not be identified at the time of sale,there will
be an additional charge of$ 72 per sheet of 4x8 sheathing and/or$ 6 per.linear ft.of dimensional lumber for decking.
If additional layers of roofing are discovered AFTER removing the first layer,or could not be!identified at the time of sale,there will be
an additional charge per square to remove each additional layer based on product to be removed:
$ 21 for composition shingles,$ 55 for wood shingles.Low or flat roofs will be priced on a per job basis based on
complexity. �'y�'��►7
CONTRACT=AMOUNT
06117/14-SA Page 6 of 6
Florida Building Code Online Page 1 of 2
✓
CCr BCIS Home Log In User Registration Hot Topics s Submit Surcharge Stats&Facts { Publications FBCjStafl { aC15 Site Map ! Links Search 1
Busines '
Professi a1 x� Product Approval
a USER:Public User
I �:
Regutftio0:
Product Approval Menu>Product or Aoolication Search>Aloolication List>Application Detail
FL# FL10124-R15
Application Type Revision
Code Version 2014
Application Status Approved
I
i
Comments
Archived
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parisppany,NJ 07054
(973)872-4421
lindareith@trinityerd.com
Authorized Signature Beth McSorley
lindareith@trinityerd.com
Technical Representative Beth McSorley(current)
Address/Phone/Email 1 Campus Drive
Parsippany, NJ 07054
(973)872-4421
bmcsorley@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
I
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
J Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity LIL LLC
Quality Assurance Contract Expiration Date 11/21/2015
Validated By John W. Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL10124 R15 COI 2015 01 COI Nieminen.pdf
Referenced Standard and Yearof Standard)) Standard Year
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
TAS 107 1995
Equivalence of Product Standards
Certified By
Sections from the Code
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquracBeV CbdMQNZD... 7/1/2015
Florida Building Code Online Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 03/31/2015
Date Validated 04/08/2015
Date Pending FBC Approval 04/12/2015
Date Approved 06/23/2015
ii
Summary of Products
F Model,Number or Name Description
10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab,,laminated, 5-tab and hip/ridge
asphalt shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL10124 R15 III 2015 03 FINAL ER GAF Asphalt
Approved for use outside HVHZ:Yes Shinales 1`1_10124-R15.Ddf,
Impact Resistant:N/A Verified By: Robert Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party: Yes
Other:Refer to ER,Section 5. Evaluation Reports
FL10124 R15 AE 2015 03 FINAL ER GAF Asphalt
Shingles FL10124-R15.Ddf
Created by IndependentThird Party:Yes
Back Next
contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
I
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,iF.S.must provitle the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
0 7W cCF_ck M
securetl'ntY.TRt('X'
I �
I�
I
I �
I l
I
I �
I
I �
I
https:Hfloridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQWtDquracBeVICbdMQNZD... 7/1/2015
EXTERIOR RESEARCH&DESIGN,LLC.
P__
;iCertificate of Authorization#9503
�' 353 CHRISTIAN STREET,UNIT#13
OX ,CT
ERD PHONEF(20D3)26209245
I
FAX:(203)262-9243
EVALUATION REPORT
GAF Evaluation Report 01506.01.08-R17
1 Campus Drive FL10124-R15
Parsippany, NJ 07054 Date of Issuance:01/03/2008
-Revision 17:03/31/2015
SCOPE:
This Evaluation Report is issued under Rule 61 G20-3 and the applicable rules;and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition;(2014) Florida Building Code
sections noted herein.
DESCRIPTION: GAF Asphalt Roof Shingles
I'
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert.Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle:
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then lit shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 5:
Prepared by: `�1,p}�i;r.;n,y��
.� �• :�_.
441
Robert W.Nieminen,P.E. ��,,-r'''
"�Ji .�•.• The facsimile seal appearing was authorized by Robert Nieminen,
• ,!��j„ tsfs`�'' P.E.on 03/31/2015.This does not serve as an electronically signed
Florida Registration No.59166,Florida DCA ANE1983 document.Signed,sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE: i
1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interes0n any company manufacturing or
distributing products it evaluates.
2. Trinity ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued. i
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
Q0TRINITYIERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the following
sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the
following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 ! 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 ! 2008
1507.2.7.1,R905.2.6.1 Wind Resistance TAS 107 1995
3. REFERENCES:
imipf Examination Reference Date
GAF(PDM 1915) Letter of Equivalency Seal-A-Ridge Impact Resistant IR 01/13/2012
PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004
PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005
PRI(TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013
UL(TST 1740) ASTM D3462 93NK6295 11/29/1993
UL(TST 1740) ASTM D3462 99NK43835 01/12/2000
UL(TST 1740) TAS 107 94NK9632 03/29/2000
UL(TST 1740) ASTM D3462 01 NK06632 02/02/2001
UL(TST 1740) ASTM D3161,TAS 107 01NK9226 05/21/2001
UL(TST 1740) ASTM D3161 01 NK37122 12/18/2001
UL(TST 1740) ASTM D3462 01 NK37122 12/19/2001
UL(rST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002
UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002
UL(rST 1740) ASTM D3161 03CA5367 03/11/2003
UL(TST 1740) ASTM D3462 03NK26444 10/17/2003
UL(rST 1740) ASTM D3462 04NK13850 06/07/2004
UL(TST 1740) ASTM D3161 04NK13850 06/23/2004
UL(TST 1740) ASTM D3161 04NK30546 03/10/2005
UL(TST 1740) ASTM D3462 04NK22009 05/06/2005
UL(TST 1740) ASTM D3161 04NK22009 j 05/09/2005
UL(TST 1740) ASTM D3462 05NK27924 02/10/2006
UL(TST 1740) ASTM D3161 05NK27924 02/11/2006
UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006
UL(rST 1740) ASTM D3161,D3462 06CA18074 06/16/2006
UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006
UL(TST 1740) ASTM D3462 06CA31603 12/01/2006
UL(TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006
UL(FST 1740) ASTM D3161 07NK05228 03/13/2007
UL(TST 1740) ASTM D3161 06CA31611 04/04/2007
UL(rST 1740) ASTM D3161 06CA61148 04/09/2007
UL(rST 1740) ASTM D3161,D3462 07CA31742 11/08/2007
UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 03/13/2008
UL(TST 1740) ASTM D3161,D3462 07CA55908 04/01/2008
UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009
UL(TST 1740) ASTM D3161,D3462 09CA06856 i 05/15/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 ! 08/27/2009
UL(TST 1740) ASTM D3161,D7158,D3462 10CA35554 03/05/2010
UL(TST 1740) ASTM D3161,D7158,D3462 10CA13686 05/15/2010
UL(TST 1740) ASTM D3462 10CA07264 05/27/2010
UL(TST 1740) ASTM D3462 10CA11953 10/29/2010
UL(rST 1740) ASTM D3161,D7158,D3462 10NK11951 10/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 10NK12070 11/04/2010
UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010
Exterior Research and Design,U.C. Evaluation Report 01506.01.08-R17
Certirkate of Authorization#9503 F1.10124-1175
Revision 17:03/31/2015
Page 2 of 5
TRIM Y I ERD
Enti Examination Reference Date
UL(TST 1740) ASTM D3161,D7158,D3462 10CA53934 03/31/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011
UL,U.C.(TST 9628) ASTM D3462 12CA34891 10/12/2012
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013
UL,LLC.(TST 9628) ASTM D3161 12CA38083 02/26/2013
UL,LLC.(TST 9628) ASTM D3161 13CA32332 06/18/2013
UL,LLC.(TST 9628) ASTM D3161 13CA37934 08/02/2013
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mobile,AL 11/21/2014
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Myerstown,PA 02/06/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tuscaloosa,AL 02/20/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Michigan Cty,IN 02/19/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Shafter,CA 01/05/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21 ,Savannah,GA 02/23/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Minneapolis,MN 02/16/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mt.Vernon,IN 02/10/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Baltimore,MD 02/11/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tampa,FL 03/05/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Dallas,TX 02/25/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Ennis,TX 03/07/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Fontana,CA 03/02/2015
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Marquis®WeatherMax°,Royal Sovereign®and Sentinel°are a fiberglass reinforced 3-tab asphalt roof shingles.
4.1.2 Camelot®, Camelot®II, Country Mansion®II, Grand Canyon®, Grand Sequoia°, Grand Sequoia®IR, Monaco® Sienna®,
Timberline American Harvest°,'Timberline° ArmorShield— II, Timberline® Natural Shadow®, Timberline HD®,
Timberline® Cool Series, Timberline Ultra HD® and Woodland® are fiberglass reinforced, laminated asphalt roof
shingles.
4.1.3 Slateline®is a fiberglass reinforced 5-tab asphalt roof shingle.
4.2 Hip&Ridge Shingles:
4.2.1 Seal-A-Ridge®Ridge Cap Shingles,Seal-A-Ridge®IR Impact-Resistant Ridge Cap Shingles and Timbertex®Premium Ridge
Cap Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Starter Strips:
4.3.1 Pro-Start®Starter Strip Shingles and WeatherBlocker'" Premium Eave/Rake Starter Strip are starter strips for asphalt
roof shingles.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieirninen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved,Roofing Materials Directory for fire
ratings of this product.
5.4 Wind Classification:
5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC'Tables 1507.2.7.1 and R905.2.6.1 to
ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable for us in all wind zones up to
Vasd=150 mph(V,,,t=194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
5.4.2 The GAF hip & ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for us in'all wind zones up to Vasd=150 mph
K,=194 mph). Refer to Section 6 for installation requirements to meet'this wind'rating.
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R17
Certificate of Authorization#9503 FL10124-R75
Revision 17:03/31/2015
Page 3 of 5
TRINITY JERD
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations
by a qualified design professional are required for conditions outside these limitations. Contact the shingle
manufacturer for data specific to each shingle.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and
F.A.C.Rule 61G20-3.
I i
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally
Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. i
6.2 Starter Shingles:
6.2.1 Installation of Pro-Start Starter Strip Shingles and WeatherBlocker Premium Eave/RaIke Starter Strip shall comply with the
manufacturer's current published instructions.
6.3 Asphalt Shingles:
6.3.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four
(4)nails per shingle in accordance with FBC Sections 1507.2 or R905.2,with the following exceptions:
➢ Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, andWoodlandrequire minimum five (5)
nails per shingle.
➢ Slateline requires minimum six(6)nails per shingle.
i
6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal,special methods of fastening are required. Contact
the shingle manufacturer for details.
6.4 Hip&Ridge Shingles:
6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles and Seal-A-Ridge IR Impact-Resistant Ridge Cap Shingles shall comply with
the manufacturer's current published instructions with a minimum two(2) nails, minimum 3/8-inch head diameter, per
shingle and nominal 0.25-inch diameter beads of Henkel"Loctite PL S30 Roof&Flashing Sealant".
11.5" Sealant
1° (292 mm) i° Sellante.
(25�m} (25,mm} Enduit d'6tanch6ite
�.. 12°
# I (305 mm) j
Nail
clay'a j
6 5/8°-7 5/8°. Clouer
(168-194 mm)
I
12°
(305 mm)
Exterior Research and Design,LLC. Evaluation Report 01506.01.08.1117
Certificate of Authorization#19503 FL10124-R15
Revision 17:03/31/2015
Page 4 of 5
I
TRINITY(ERD
6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply lwith the, manufacturer's current published
instructions with a minimum two(2) nails, minimum 3/8-inch head diameter, per shingle and beads of Sonneborn NP1
Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant.
(2
MMI,
3 5 rnm4, i:ndu4l�i ktarsckta a
I
S
Nip
ucr
'(305 s�ni
1�39,rni'?s�;
j
I
ti rriw�
6.4.3 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table
1507.2.7.1/R905.2.6.1. -
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
i
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(847)664-3281
END OF EVALUATION REPORT-
i
I
i
.i.
'i
i,
Exterior Research and Design,U.C. Evaluation Report 01506.01.08.1117
Certificate o/Authorization#9503 FL10124-R15
Revision 17:03/31/2015