Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online s: _ ��'i '',i_iI � �;3 �� mtr�Y'ar� t�• �S Sam it w'��og !: �k� �n n t�r�r��, t-J 9t( ai�i 5•. 7 pF , �i 0 ,,,l,fi rai�� bb ^c4 x &(qe '•+1 t EFdF € '43 i € k. '4 l F h� .,r .!1 � 1..`i ��—�e44� f .' S ,...: ki�rs1. d t a 1�'�� •- � i[• �t, ,4r��.r�:uz:.s•_�a'�aelr �,t...1. .iss:,ii.�c.r�u SCIS Home Log In ? User Registration i~Hot Topic ; Submit Surcharge Stats&Fads i Publications { FBC.Staff BCIS Site Map Links. Search b ( * Product Approval p� d- &-,%, r USER:Public User fl + 511` )'_r4duct Aooroval Menu>Product or Apolication Search>Application List>Application Detail FL-# FL10674-1112 Ott Application Type PP yp Revision Code Version 2014 Application Status Approved 'Approved by DBPR._Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived D Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owepscgrning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1-Owens Corning PKWY Toledo,OH 43659 (419)376-8360 mel.sancrant@owenscbrnig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory AsphaltShingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert J.M.Nieminen the Evaluation Report i Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/20/2017 Validated By John W. Knezevich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R17 COI 2016 01 COI Nieminen.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Equivalence of Product Standards Certified By Sections from the Code http://www.fibridabuilding.org/pr/pr_tLpp_dtI.aspx?param=wGEVXQWtDgtBNbEY5 V%2... 4/10/2017 rionaa nu ging «vane Untrue Page 1 of 1 y 1 kN aclS Home Login User Registration Hot Topics Submit Surcharge Stats&Facts PublicationsFSC Staff 'Cffi.Srce Map Links` Search. d b*pr rljj,,Product Approval #,rUSER:Pub1SCUser 7=M.AU,.VyQj 6tjy>,p,n,s +-:r,Arg;; tt n�=��r n:ApplimVen list f;,,•.F ,., Search Criteria Il�fine S!�areh Code.Version 2014 FL# 10674.1 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model,Number or Name. ALL Product Description ALL Approved for use"in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Results-Applications Tyats_. £�drer Vasi;rntfed By E2's33.ua F!10674- Revision Owens Corning John W.Knezevich, Approved FL#r FL10674.1 PE : tslctory Model:Owens Coming Asphalt Roofing Shingles and Starters (954)772-6224 Description:3-tab,4-tab,5-tab,laminated,starter and hip& ridge shingles Category:Roofing Subcategory:Asphalt Shingles 'Approved by MR.Approvals by DBPR shall be reviewed and ratified by the POC and/orthecon rrdssldn if necessary. Contact us::2601 Blair Stone Rgad,TallaMsma FL 32399 Phone:850-481-1824 The State of Florida Is an AA/EEO employer. •'+ov ht 2007-7013 state of Florida.::Privacy Statement::AccuslbBity Statenwtt::RQfund Statentent Under Florida law,email addresses are public records.if you do not want your e•ma8-address released in response to a publIc-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional maii.It you.have any questions,please contact 850.487.1395.-Pursuant to Sectlan 45S.27S(1),Rodda Statubes,effective October 1,2012,licensees licensed under Chapter 455,F.s.must provide The Department with anemail address If they have one.The cmats provided may be used for official communication with tho licensee.However email addresses are public record.If you do not:wish to supply a personal address,please provide the Department With in email address which can be made available to the public.To.determ'me if you are a.licensee under Chapter 455.FS.,please diel:hem- Product em-Product Approval Accepts: Safe it�lfd ilf N ..�U4: littps://www.floridabuilding.org/pr/pr_appjst.aspx 1/8/2017 EXTERIOR RESEARCH&DESIGN,LLC. Certlficate of Authorization 119503 353 CHRISTIAN STREET,UNIT#13 TRINITY . ERD OXFORD,CT 06478 PHONE:(203)262-9245 EVALUATION REPORT FAX:(203)262-9243 Owens Corning Evaluation Report 037940.02.1247 One Owens Corning Parkway FL10674-R12 Toledo,OH 43659 Date of Issuance:02/06/2012 Revision 7: 04/18/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product Change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this.Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: LU ,'%?F�.�'^R�•�.r'C^.`• The facsimile seal appearing was authorized by Robert Nieminen, Robert J.M.Nieminen P.E. s- � :,rq�� tjd�4' P,E.on 04/18/2016.This doc;not serve as an electronlwlly slgnetl Florida Registration No.59166,Florida DC4 ANE1983 document.signed,sealed hardcoples have been transmitted to the Product Approval Administrator and to the named dent CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned,operated or controlled by any company manufacturing,or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any-other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose: . . ' ~/ n� 8 �R[� ] ' u � �m n o .�-- -- ` ROOFING SYsTEmsEVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles compliance Statement: Om/ens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated compliance with the following sections ofthe Florida Building Code and Florida Building Code, Residential Volume � through testing inaccordance with the following Standards, Compliance issubject tothe Installation Requirements andiim|tadons/Conditions ofUse set furthherein. 2. STANDARDS: Section Propert Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM n34s2 2009 1507*2.7.1,8905.2.6.1 Wind Resistance ASTM D3161 zVoy 1507.2.7.1,R905.2.6.1 Wind Resistance Asz^xD7zsV aoum 3. REFERENCES: 900Y Examination Reference Date oLLLI(CEg9626) Physicals&Wind Reyi$ohce File 8z453,Vol.3 02y15/2007 uLLLC(cERy62o) Physicals&Wind Resistance 20120516-n2453 05/16/2012 uLLLC(TsT9sau) Physical Properties 06cx20263 04/18/I006 oLLLC(TST9*2V) Wind Resistance 11CAj4308 02/18/2012 UL LL[(TSTyo2o) Physicals kWind Resistance 4786093137 02/01/2014 oLLLC(TSTy*2x) Wind Resistance 4786126532 02/10/2014 UL LLC(TSn9o2u) Pkv,ica|ymcert/es Classification letter 02/13/201* uLLLC(TSToazu) Physical Properties Classification letter ' 10/02/2015 x4iami-umje(CEn15yZ) FaCMVUZ Compliance Ya,ioua1uOAa va,mu* UL LLC (QU»ynuS) Quality Control Service Confirmation,nz45a Enp.,08/�0/20i7 4, PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic'and Supreme'are-fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire'are fiberglass reinforced,4-tabasphalt roof shingles. 4.1.3 Devpnsh/ra"`are fiberglass reinforced,5-tabasphalt roof shingles. 4.14 Duration', TruDefinition° Duration*, Duration' Premium Cuoi, TruDcfinitkon~ Duration~ Designer Color CoUention.Trunefinition^O.akr|dQe°' Oakridge' and VVeathe,guand' HPare fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire'Hip & Ridge Shingles, High Ridge, WeatherGuard'HP Hip&Ridge Shingles,ProEdge Hip&Ridge Shingles and DoroRid0e`"Hip&Ridge shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. ' 4.3 -Startcr3t/ipShinO|e'5tarterSt,ipP|usandstarterShinQ|eRoUa,estarte,ntdpofnr^spha|tronfshing|es. S. UKx|TA[ONs; 5.2 This is-a building o?da evaluation. Neither Trinity IERD nor Robert Nieminen, F�E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/wasused for permitting or design guidance unless retained sp'clfically for that purpose. 5.2 This Evaluation Report isnot for use intbaMVMZ. 5.3 Fire,Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings ofthis product. Exterior Research and v°sm" U.C. Evaluation Report o37y4m.oz.z2-nr Certificate ofxvth"riz"m=uexa n10674�1,2 Revision 7:04/18/2016 Page cu[u . . � .. � '���� ~ « :�� ��TY�+^^^� 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified � u�o�n� withR� Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161 Class F and/or ASTM D71� Class H, indicating the shingles are acceptable for use inall wind zones uptoV=d=1sVmph(Vul,=1g4mph). Refer toSection 6forInstallation requirements to meet this wind rating. 5.4.2 All Owens Corning hip&ridge shIngles,Starter Strip Shingle and Starter Strip Plus noted herein are Classified |naccordance with F8CTables 15O7.2.7.1and Re05.%,6.1tnASTM D3161,Class F,indicating the shinglesare acceptable for use|nall wind zones uptoV,,d=15Omph (V"lt=194mph). Refer toSection Gfor installation requirements tpmeet this wind rating. 5.4.3 Classification by ASTM D7158applies to exposure category U or [and a building height of6Ofeet or less, Calculations byaquoUfieddesign professional 'are required for conditions outside these limitations. Ojn%aot the shingle manufacturer for data specific toeach shingle, 5.4.4 Refer to Owens Corning published information on wind resistance and Installation limitations. 5.5 All products in the roof assembly shall-have quality assurance audit'in accordance with the Florida Building Code and F.A.C.Rule G1GZO' . 6' ]wsnALu^nom: 6.1 Underlayment: 6.11 undedayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,orbeLocally Approved per Rule GIG20-3, per FBCSections 150Ji.2.3'15O7.Z.4orR805.2.S. 6.2 Asphalt Shingles: 6,2.1 Installation of asphalt shingles shall comply with the manufacturer`s current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: > Berkshire' �shin |esrequ|namin(mum�ve(�)naKopershin�}e . � VVeather8uardHPshingles require minimum six(6)nails per shingle. � Devonshire—shingles require minimum six(6)nails per shingle. � Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 62.2 Fasteners shall be in accordance with the manutacturer'spubi!shed requirements, but not less than F8C 15O7.Z.6orR905.Z.5. Staples are not permitted, 6.2.4 Where the mm7 slope exceeds 21 unity vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip P|uo� ' Ddp_ Drip Drip edge edge edge located 3'from eave V-3`front eave, install first Seff-sealitif;adhesive Instal first Starter Strip Flis 6"removed Starter Strip shingle everimnus eaves and rakes Starwr Strip Plus ove.-hangs eav*s and takes IM-3W e*"a",x"=""=aand o°*n�u�. evawauvnnnpv�oy�4ou �z.1nr u�����mmration M113 R10674-1112 Revision 7'u4118/2cuo Page un,u T .I I ;ERD 6.2.6 Minimum Nailing—Classico&..Supreme; ij - r Normal Manowd or Area para NormalMonoard or Area para Wind Areas High Wind dedvanas y Wind Aieas f4-1h Wind doovenos y Area para vienros norma#os Areaa vieoroe fuerras Aran para vionros norma#os Areas vlantos facritas �'teIla 6"Exposure- 5 618"Exposure fxposlcf6n Expoeiot6n 6.2.7 Minimum Nailing-Berkshires': Sextant strip Seataat slrlp to iira de sObdor /Ea Eire de sellador o ----+d ■ ► ■+1—ter.• •.�--+• 1' • r r..��r s S Yx" 9 ve 9 In. ve } 8 4a" 8 ih" a 4Y' H IT } t r t Standard Fastening Pattern 6-Nail Fastening Pattern v , Via'®n snbrit strip {a Gra do sdkdor R•t---->9r---re 04--------'va--->• owl R iii' 8 YY' RYf t" r`21p AsphaR.roafingcoment f Crr!,tslto de tochodo astafro Mansard or Steep Slope Fastening Pattern Exterior Research.and Design,I.I.C. Evaluation Report 037940.02.12-R7 Cartfpcou of Authorization#19563 FL10674-R12 Revision 7:04/18/2016 Page 4 of 8 TRINITY,:ERD 6.2.8 Minimum Nailing—Devonshire",: t 1 N 7" I 8� t.-8�.i• 8�t I Nail aaW�1 r I Nails 53/8"exposure y: ; Expostcion de 5 3!B palg Sealant location tibicacidn del sellador Ten 1"Spots of Asphalt Roof Cement Standard 6=Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6,2.9. Minimum Nailing—Duration°,TruDefinition® Duration, Duration® Premium Cool &TruDefinition' Duration' Designer Color Collection: 4-Nall Fastening Pattern 6-Nall Fastening Pattern slabnam=411ing arta Width 3unN3Wfaat4n1na ana%idth Me14 ryr-- pmat Nail Typical i2 F1 F� &1B"5318' 8-78"Y!B" gyp.... Standard Fastening Pattern 6-Nail Fastening Pattern Fastening ror Slopes Grcater Than 21:12 SuroNM.H lettent"a Men witllh Nail,iypicm i• fr � u. i„ — —x -- — 6.1.V ss+s- -tour 1"3po4 of Arylalt Roodtty e^menl Mansard or Steep,Slope Fastening.Pattern Exterior Research and Design,LLC. Evaluation Report 037940:02:12-R7 Certificate of Authorization#9503 FL10674•R12 Revision 7:04/18/2016 Page 5 of 8 1 I I (:ERD 6.2.1 Minimum.Nailing—TruDefinitionbOakridge®,Oakridge°: 4 Nail Pattern 6 Nall Pattern Esquema tort 4 ciavos- Esquatna Cott S darns IAF--- t2 --*'1 r- 6618"Exposure, Nags 55/8'Exposurs t4ab Expasttl4v de 5518putg. Clavas Expostdon da 65/OP4 6618`Exposure Clavus 6 618"Expasate &poskhinde 5S/8pulg, Expoucidn de 6918pa1g.. Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for slopes Groater Than 21:12 srirenmr>u Uoranlrie oroa wlam r naIt ryP« 61.2^ssa• - ' four 1"spotty 0Uphel RxMs Cement Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing—WeatherGuardo'HP: 21nnlsside Vlew Fiwst3hnse�tt Brl}Lto� Citws/In Atlfn�ls i Exterior Research and Design,LCC. Evaluation.Report 037940.W.1Z-R7 Certtflrate of Authorization 119503 FL10674-R22 Revision 7-04/18/2016' Page 6 of 8 TRINHY'ERD 6.3 Hip&Ridge Shingles: 6.3.1 Installation of gerkshire Hip and Ridge Shingles, High Ridge, WeatherGuardo HP Hip and Ridge,Shingles and ProEdge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions,using four (4) nails per shingle. ge Installation of DuraRid - Hip& Ridge.Shingles shall comply With the manufacturer's current published instructions, using two (2) nails per shingle. Refer to Owens Corning published n'' Informatioon -wind resistance and installation I limitation-s, including the use of hand-s6allng for wind' warranties. 6.3.2 Fasteners shall, be in accordance with the manufacturer's published requirements, but not less than FK 1507.2.6 or R905:15; Stapies:are not permitted. 6.3.3 Minimum Nailing— ailing—BerkshireO Hip&Ridge and High Ridge: Fig.1 4 019.2 Uais ANals hails Piwe 4- X + ti, 6.3.4 M i.nimum Nailing—WeatherGuard®HP Hip and Ridge: Fig.6 Hip'&Ridge Shingle Fastening Fig.A 4 4 TOP VWi t—Cttroctbn RAS WIs 2 Exposure Exterior Research and Design;LLC; Evaluation Report 037940.02.12-111 CertIfIcate ofAu.I thlorization#9303 FL10674-RI2. Revision 7:04/18/2916. Page 7 of 8. Florida Building Code Online Page 2 o 2 Product Approval Method Method I Option D Date Submitted 04/18/2016 Date Validated 04/19/2016 Date Pending FBC Approval 04120/2016 Date Approved 06/08/2016 Summary of Produ cts FL# Model, Number or,Name Description 10674.1 Owe-ns Corning Asphalt Roofing 3-tab,4-tab,5-tab, laminated,starter and hip&ridge Shingles and Starters shingles Limits of'Use Installation Instructions Approved for use in HVHZ: No, FL10674 R12 11.2016 04 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES ELI0674-R12.pc1f- Impact Riiis istaint:N/A Verified By: Robert].M.Nieminen PE- 50166 Design Pressure:N/A Created by Independent Third Party:*Yes Other:Refer to ER,Section 5. Evaluation Reports FL10674 R12 AE 2016 04 FINAL ER OC ASPHALT SHINGLES FL10674-RI2.pdf Created by Independent Third Party:Yes sack Next Contact Us::2601 Blair Ston,Road Tallahassee F4 32399 Phone;flS0-487-12 The state of Florida is an AAJeO employer.Copyright 2007-2013 State of Florida.;:PrivacvSigtemcat::Accessibility Statement Refund Sta Under Florida law,email addresses are public records.If you do,not want your e-mail address released-In response to'a pubtic-records request,do not send electronic mail to this entity.instead,contact the office by Phone or bre y traditional mail.If you have any questions,Please contact 850.487.1395.-Pursuant to Section 455,275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must p vicki the Department with an email address if they have one.The emaKs provided may,be used for Official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can'be made available to the public.To determine If You are a Licensee under Chapter 455,F.S.;please click b gcp-. Product Approval Accepts: Credit Card' Safe littp://www.floridabuilding.org/pr/pr_app_dtl.aspx?paran-i=wGEVXQwtDqtBNbtY5V`/`2... 4/10/2017