Loading...
HomeMy WebLinkAboutProduct Approval §e V41- t vi BCIS Home Log In User Registration i Hot Topics j Submit Surcharge Stats&Facts Publications FBC Staff i BCIs Site Map links Search Florida :" Product Approval look& r k ' `USER Public User Product Approval Menu>Product or Application Search>Application Ust>Application History>Application Detail R 9 FL# FL20838-RO � Application Type New Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenup Ocala,FL 39474 (352)368-6922 Ext 255 sbrooks@cws.cc Authorized Signature Stephen Brooks sbrooks@cws.cc Technical Representative Stephen Brooks Address/Phone/Email 1900 SW 44th Avenue Ocala, FL 34474 (352)368-6922 Ext 255 sbrooks@cws.cc Quality Assurance Representative Jay Lathrop Address/Phone/Email 1900 SW 44th Ave. Ocala,FL 34474 (352)368-6922 Ext 291 jlathrop@cws.cc Category Exterior Doors I Subcategory Sliding Exterior Door Assemblies 9 Compliance Method Certification Mark or Listing Certification Agency Keystone Certifications,Inc. Validated By Steven M.Urich,PE Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2011 ASTM E 1886 2005 ASTM E 1996 2009 TAS 201/202/203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 07/13/2016 Date Validated 07/13/2016 Date Pending FBC Approval Date Approved 07/17/2016 Date Revised 11/08/2016 Summary of Products .I FL# Model,Number or Name Description 20838.1 SGD 8800 Sliding Glass Door•8800 Series-4'X 8'Panels Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL20838 RO C CAC 138-1394CAR.pdf Approved for use outside HVHZ:Yes FL20838 RO C CAC 138-1395CAR.pdf Impact Resistant:Yes FL20838 RO C CAC 138-1397CAR.pddf Design Pressure:N/A FL20838 RO C CAC 138-1398CAR.pdf Other:Impact vinyl slidinglass door with light FL20838 RO C CAC 138-569CAR.df reinforcement,standard sill riser,and annealed laminated FL20838 RO C CAC 138-570CAR.odf glass to+/-DP50. Design pressure+/-65 with light Quality Assurance Contract Expiration Date reinforcement,standard sill riser,&heat strengthened 04/18/2020 laminated glass. Installation Instructions FL20838 RO II CWS-1150.pdf Verified By: Lucas Turner FL PE 58201 Created by Independent Third Party:Yes Evaluatioq Reports FL20838 RO AE' EvalReport1150.pdf Created by Independent Third Party:Yes i 20838.2 SGD 8800 Sliding Glass Door 8800 Series-5'X 8'Panels Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL20838 RO C CAC 138-1601CAR.pddf Approved for use outside HVHZ:Yes FL20838 RO C CAC 138-1602CAR.odf Impact Resistant:Yes FL20838 RO C CAC 138-571CAR.odf Design Pressure;+80/-80 Quality Assurancel Contract Expiration Date Other:Impact vinyl sliding glass door with heavy 04/22/2020 reinforcement and high sill riser to+%-DP80. Installation Instructions FL20838 RO II CWS-1151.Ddf Verified By: Lucas Turner FL PE 58201 Created by Independent Third Party:Yes Eva luatioq Reports FL20838 f20 AE EvalReport1151.pdf Created by Independent Third Party: Yes 20838.3 SGD 8800 Sliding Glags Door 8800 Series-4'X 10'Panels Limits of Use Certificatipn Ageni Certificate Approved for use in HVHZ:Yes FL20838 RO C CAC 138-1604CAR.odf Approved for use outside HVHZ:Yes FL20838 RO C CAC 138-1605CAR.pdf Impact Resistant:Yes FL20838 RO C'CAC 138-572CAR.odf Design Pressure:+65/-65 Quality Assurance Contract Expiration Date Other:Impact vinyl sliding glass door with heavy 04/22/2020 reinforcement and standard sill riser to+/-DP65. (Limited to Installation Instril ctions 4 Panel Configurations) FL20838 RO II CWS-1152.p_df Verified By: Lucas Turner FL PE 58201 Created by Independent Third Party:Yes Evaluation Reports FL20838 kO AE EvalRep_ort1152.0 Created by Independent Third Party:Yes Contact Us::2601 Blair stone Road.Tallahassee FL 3239 Phone:850-487-1824 The State of Florida Is an AA/EE.Q employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement i I Docunent Title: Doc No: FIRM 81.43 Impact Performance Rev No: i4 Page., 1 of 1 KEYSTONjel Certification CCIiTPICATONS•INC. U Authorization Report Required By: PRO B1-03 J d CAR& Product ID Number: 138 - 570 Issue Date: 6/24/2016 Revision Date: 6/24/2016 Expiration Date: 4/18/2020 Company Code: 138 This Certification Authorization Report(CAR) is issued by Keystone Certifications, Inc. (KCI) after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the specified referenced standard. Actual fenestration product performance may vary based on many factors, including installation, condition of the wall/roof substrate and the age of''the product and installation components. This report indicates the product is eligible for the application of Keystone Certification Program certification labels. Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in this report can be verified at www.keystonecerts.com. Licensee Information: Product Information: Custom Window Systems, Inc Model: SGD 8800 Impact Sliding Patio Door 1900 SW 44th Avenue Operator Type: SD !� Ocala FL 34474 Config: All/Ast/SR, GS-7/16" HS'Lami Mono or IG Max Width: 288 Max Height: 96 Corresponding Structural CAR's: 1138-1397.0 Referenced Standard: Product Rating: ASTM E1886-05/E1996-09 Missile Level D,Wind Zone 4, DP +/-65, 288x96 XXXXXXP Qualifying Test Information: Test ReportNo: ATI-F1575.05/.06/.08/.09/.10/.11-401-44 Test Report Expiration: 4/18/2020 Authorized Signature: Keystone Certifications, Inc.! 2� 6.��.27 564 Old York Road, Suite 5 Etters, Pennsylvania 17319 ;Phone: 717-932-8500 07:+49: 8 -04'00' Fax: 717-932-8501 WWW.KEYSTONECERTS.COM Docunent Title: Doc No: FIRM B1-43 Impact Performance Rev No: 4 Pam: 1 of: 1 EYSTONJ[ l Certification C¢RTPI CATIONff3.INC. �J Authorization Report Required By: PRO B1-03 CAR& Product ID Number: 138 - 569 Issue Date: 6/24/2016 Revision Date: 6/24/2016 Expiration Date: 5/11/2020 Company Code: 138 This Certification Authorization Report(CAR) is issued by Keystone Certifications, Inc. (KCI) after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the specified referenced standard. Actual fenestration product performance may vary based on many factors, including installation, condition of the wall/roof substrate and the age of the product and installation components. I This report indicates the product is eligible for the application of Keystone Certification Program certification labels. t icensee stipulates in affixing certification labels to products, that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing suchl!a certification label shall'b,e considered certified. The information in this report can be verified atwww.keystonecerts.com. Licensee Information: Product Information: I Custom Window Systems, Inc Model: SGD 8800 Impact Sliding Patio Door 1900 SW 44th Avenue Operator Type: SD Ocala FL 34474 Config: All/Ast/SR, GS-7/16"Ann1 Lami Mono or IG Max Width: 288 Max Height: 96 Corresponding Structural CARs: 138 -1394.0 I Referenced Standard: Product Rating: ASTM E1886-05/E1996-09 Missile Level D, Wind Zone 4, DP +/-50, 288x96 XXXXXXP i Qualifying Test Information: Test Report No: ATI-F1575.05/.06/.08/.09/.10/.11-401-44 Test Report Expiration: 5/11/2020 I Authorized Signature: Keystone Certifications, Inc. 20 6.6.27 564 Old York Road, Suite 5 Etters, Pennsylvania 17319 07:47:06 -04'00' 'Phone 717-932-8500 Fax: 717-932-8501 W W W.KEYSTONEC ERTS.COM I - GENERAL NOTES: SLIDING GLASS DOOR - LARGE MISSILE IMPACT 1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND WINDOW WINDOW SYSTEMS MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING 1900 SW 44TH AVE., CODE(FBC),CURRENT EDITION AND IS RATED FOR USE IN THE OCALA,FLORIDA 34474 HIGH VELOCITY HURRICANE ZONE(HVHZ)AND IS RATED FOR WNW.CWS.CC WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED IN _ ASTM E 1996 PER THE FBC. 185 "4 PANEL WIDTH 8800 PVC - 2.GLAZING OPTIONS:(SEE SHEET 3) 4�„ SLIDING GLASS 16 3.APPROVED CONFIGURATIONS INCLUDE BUT ARE NOT DOOR-IMPACT MAX.PANEL WIDTH LIMITED TO: A POCKET "XO" "OX" "XX""OXO„ "XXX„ "OXXO" "XXX)C "PX" "PXX" "PXXX""PXXXX" "PXXP" "PXXXXP" "PXXXXXXP", m 2 TRACK,3 TRACK,4 TRACK I 40�"GLASS DLO - - II - 4.DESIGN PRESSURE RATING: II -NEGATIVE DESIGN LOADS BASED ON,TESTED PRESSURE > II AND GLASS TABLES ASTM E-1300-04. m m 96" I II -POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE, 0 Z MAX. _ WATER INFILTRATION TEST PRESSURE AND GLASS TABLES I.L. 0 UNIT B I II C B ASTM E-1300-04. cn HEIGHT I II 11 W •• j I II B 5.ANCHORAGE:THE 33 1/3%STRESS INCREASE HAS NOT BEEN a O 93j' I �/ II I 11 USED IN THE DESIGN OF THIS PRODUCT.SEE SHEETS 10-11 m MAX. I X X II X /� I F FOR ANCHOR DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 U W PANEL II 12 WAS USED FOR WOOD ANCHOR CALCULATIONS. Wm HEIGHT Cl W I II G 6.PRODUCT APPROVED FOR IMPACT USE. SHUTTERS ARE NOT 840,, II 12 REQUIRED. 0 GLASS II z DLO II 7.ALL FRAMES ARE PROCESSED AND SCREWED II TOGETHER.VENTS ARE PROCESSED AND THERMAL WELDED I I III TOGETHER. ��GENSFGQy� II 8.SERIES/MODEL DESIGNATION SGD-8800. v tNo 58201 t�'1 9.THE DESIGNATION X AND 0 STAND FOR THE FOLLOWING: E D A A X=OPERABLE SASH,0=FIXED SASH,P=POCKET/HOOKSTRIP �9O. STATE OF :�W 12 12 11 10.SECTION CALLOUTS APPLY TO ALL CONFIGURATIONS INA �i�S O.. . SIMILAR LOCATION. 11.WEEP SLOTS=1/2"x 1"LOCATED @ BOTH ENDS. 11/21/2016 LUCKS A. LUCAS A.TURNER,P.E. FL PE#58201 Turner 1239 JABARA AVE. 2016-11-21 NORTH PORT,FL 34288 10:37+19:00 PH.941-380-'1574 TABLE OF CONTENTS. SHEET DESCRIPTION: GENERAL NOTES&ELEVATIONS....1 DESIGN PRESSURE GLASS TYPE GENERAL NOTES AND SECTION VIEWS.................................2 MAX.PANEL SIZE RATING (SEE SHT 4) IMPACT RATING ELEVATIONS BOM&GLAZING DETAIL....................3 DRAWN BY: DATE: EXTRUSIONS...................................4-5 +/-50 PSF A LARGE MISSILE BLZ TRACKWIDTHS..................................6 48-15/16"x93-3/8" +/-65 PSF B IMPACT DWG#: REV.:05/06/16 ANCHOR SCHEDULE&NOTES........7 ANCHOR PATTERNS......................S-9 CWS-1150 1 INSTALLATION DETAILS.............10-11 •(4)PANELS SHOWN;HVHZ LIMITED TO MAX.(9)PANELS. OUTSIDE HVHZ,UNLIMITED NUMBER SCALE: SHEET OF PANELS IS ALLOWABLE AS LONG AS INDIVIDUAL PANELS DO NOT EXCEED PANEL SIZE AS SHOWN. 1:30 1 OF 11 41 28 11 40 6 WINDOW SYSTEMS 35 14 1900 SW 44TH AVE. 12 34 34 �� OCALA,FLORIDA 34474 60 35 q o O P WJINV.CWS.CC 14 10 ❑ ❑ a 0 39 29 28 56 23 d d 8800 PVC a a o P 34 14 SLIDING GLASS ❑ ❑ ❑ ❑ Da 39 DOOR-IMPACT 30 d d e� 19,20,21,58 P 34 O ao w 36 14 ¢Q 13 13 � 15 ❑ d d EIT @$ 19,20,21tr,58 1P m m U 33 16 34 14 �u 0 Z 36 SECTION VIEW B-B 6 z O 13 Lo w 66 3s a¢ F (�� U) a 6 Bio °c O a O(]o LJ� o pp ¢ o ,2 CI a O `%uuurrrp ,, z 38 IL"JI 59 13 :�,Q�?PGENS q o t No 58201 '�- =*: 16 v: ;¢_ ❑ '9=. STATE OF :L, ... FIXED PANEL 33 ATTACHMENT If� ❑ ❑ o 36 11/21/2016 32 17 LUCAS A.TURNER,P.E. 8 FL PE#58201 1239 JABARA AVE. 23 NORTH PORT,FL 34288 63 PH,941-380-1574 1 II 0 SHEET DESCRIPTION: 3 �190� ���� °�� rmcao SECTION VIEWS 67 39 27 ALTERNATE SILL RISER VIEW DRAW BY: DATE: SECTION VIEW A-A LIMITED TO+65 BLZ 05/06/16 NO SILL RISER DWG REV.: NOTES: CWS-1150 1 ITEMS NOT SHOWN FOR CLARITY: 1)INSTALLATION W/NO SILL RISER ALLOWED TO THE FULL DP'S INDICATED ABOVE,IN LOCATIONS WHERE WATER INFILTRATION RESISTANCE 20,24-26,31,55-58,61-62,64-66 IS NOT REQUIRED,SUCH AS BUT NOT LIMITED TO LOCATIONS WHERE AN OVER HANG IS PRESENT THAT IS AS WIDE AS THE WALL IS TALL, SCAL : SHEET 1:3 2 OF 11 PARTS LIST PARTS LIST ITEM PART# DESCRIPTION VENDOR MATERIAL ITEM PART# DESCRIPTION VENDOR MATERIAL �j7/J(�ajJ}) • 1 GLASS SEE THIS SHEET 51 S-2058 Screen,3-Track Sill Ke mark Aluminum WINDOW SYSTEMS 2 H•6161 2-Track Sill Vision PVC 52 S-2059 Screen,Snap Corer Ke mark Aluminum 1900 SW 44TH AVE. 3 1.6163 3-Track Sill Vision PVC 53 S-2070 Screen,Interlock Profile Aluminum OCALA,FLORIDA 34474 4 1.6165 4-Track Sill Vision PVC 54 P-5477 Block,Anti-Lift Lawrence Nylon WWWCWS.CC 5 K6160 2-Track Head/Jamb Vision PVC 55 P-5559 Screw,#14 x 4"PH PN SMS Fastenal Steel 6 H-6162 3-Track Head/Jamb Vision PVC 56 P-4269 Screw,#8 x 1"PH PN Tek Fastenal Steel ` 8800 PVC 7 1 H•6164 4-Track Head/Jamb Vision PVC 57 P-3556 Screw,#8 x 2.5"PH FL Tek Fastenal Steel 8 S-2064 Roller Track Insert Ke mark Aluminum 58 P-4962 Screw,#8 x 3"PH FL Tek Fastenal Steel 25 SLIDING GLASS 9 1 S-6171 Corer,Sill Track Vision PVC 59 P-5565 Screw,#12 x 1 1/2"PH PN SMS Fastenal Steel FRAME CORNERS DOOR-IMPACT 10 1 S-6169 ICo%er,Interlock Vision PVC 60 P-5566 Screw,#12 x 2 1/2"PH PN SMS Fastenal Steel MECHANICALLY FASTENED 11 1 S-6172 I Corer,E)dernai Reinforcement/P-Hook Vision PVC 61 P-3609 Bumper,Panel Stop Parker Seals Rubber 1;e 12 1 S-6175 ITrack Filler,Frame -Vision -PVC---- — 62 P-4291—Panel-Sto Housing -- _ —M-&M_ _ Nylon 13 I F6166 Panel Stile/Rall Vision_ - PVC 63 P-5479 Foam Block,Open Cell,0.84,V_x 0.531"x 1" Lamatek --- --- — o 14 I F6168 Interlock,Snap-On Vision PVC 64 P-5492 Gasket,Frame Assembly,2-Track Lamatek Butyl 15 1.6167 Astragal Vision PVC 65 P-5493 Gasket,Frame Assembly,3-Track Lamatek Butyl m m 16 1+6170 Glazing Bead,I.G.,1" Vision PVC 66 P-5494 Gasket,Frame Assembly,4-Track Lamatek Butyl 17 1.2060 Sill Riser,2.876' Ke mark Aluminum 67 P-4659 Dust Plug,1-1/4"x 3"x 0.5" Ultrafab 0 Z LL 18 1.2062 ISill Riser,4.06Z' Ke mark Aluminum 68 P-4366 Dust Plug,1"x 3"x 1" Ultrafab ? O 19 P-5517 113anel Guide,Interlock Bear's Metal Aluminum 69 :green,Spline Team Plastics Rubber y 20 P-5558 Support Channel,Bot Rail,Interlock Bear's Metal Aluminum 70 reen,ClothU w z a �21 P-5511 Corer,Panel Guide,Interlock Lawrence Ion 71 Duraseal IGSpacer Quanex AIumIB I 9 a 22 1 P-5516 18racket,Fixed Panel Bear's Metal Aluminum PANEL CORNERS o THERMAL WELD w U 23 P-3300 I Wts .,0.280"x 0.187"Back Fib,Black Ultrafab 1"OVERALL 1"OVERALL 19 0 y 24 P-3438 Backbeddin ,Purfect(.gaze"H'Hot Melt Henkel/Sika Silicone 18"TEMPERED 16"TEMPERED Q p 25 P-3514 Screw,#10 x 2"Ph Comb Hd Fastenal Steel 3"AIRSPACE AIRSPACE O 26 P-3587 Screw,98 x 1"PH FL TEK-Roller Asm/Mortise Lock Fastenal Steel e a ILI Z 27 P-3752 Hole Plug,0.500"Dia. Progress Plastics Ion 16'ANNEALED T6- HEAT STRENGTHENED % , 28 P-3789 Handle Set With Thumb Turn Amesburyor Roto ­kLAMINATED "LAMINATED �.�y PNC• �w T��,,�� 29 P-3792 Keeper Amesbury .`6�•'�r S�•'Py .105"PVB INTERLAYER 105"PVB .J•• ��, 30 P-3793 Multi-Point Mortise Lock Amesbury INTERLAYER zv: No 56201 •:'A 31 P-4250 Screw,#10 x 2.5"PH PN SMS-Keeper Fastenal Steel 16'ANNEALED =*G k HEAT STRENGTHENED 32 P-5287 Tandem Roller Assy,2.125"Dia Wheel Amesbury16 '-0: ea= 33 P-5438 Setting Blocks,0.090"x 0.875"x 1.5" Franke Lowe Rubber 190 STATE OF :�lri ' 34 H-1769 lReinforcernent,Interlock Ke mark Aluminum 4�c�`s0 R 10.GN=�', 35 1.2068 Reinforcement,Astragal Ke mark Aluminum 16 16 �'�,S/ONAv_ o%� 36 S-1775 Reinforcement,Lock Sfile/Rails Ke mark Aluminum Z'•GLASS BITE Z"GLASS BITE ���.8r'191110 37 H-2111 Reinforcement,HD,Interlock Ke mark Aluminum 33 a 33 e z2 38 S-2071 Reinforcement,E#ernal,Interlock Ke mark Aluminum 39 S-2069 Frame Insert,Installation Anchors Ke mark Aluminum 71 24 PURRFF_EEHT 71 24 URFE 11/21/2016 40 12063 P-1-look Ke mark Aluminum LUCAS A.TURNER,P.E. 41 S-2065 P-Hook Adaptor Ke mark Aluminum FL PE#58201 42 S-2048 Screen,Astragal Ke mark Aluminum 13 13 1239 JABARA AVE. 43 S-2050 Screen,1-Track Head Ke mark Aluminum NORTH PORT,-1 34288 PH.941-380-1574 44 1 K2051 IScreen,1-Track Jamb Ke mark Aluminum SHEET DESCRIPTION: 45 1 S-2052 Screen,1-Track Sill Ke mark Aluminum U `ul lu/ `tfl BOM AND GLAZING 46 S-2053 Screen,2-Track Head Ke mark Aluminum DETAIL 47 S-2054 Screen,2-Track Jamb Ke mark Aluminum GLASS TYPE A GLASS TYPE B DRAWN BY: DATE: 48 S-2055 Screen,2-Track Sig Ke mark Aluminum DESIGN PRESSURE BLZ 05/06/2016 49 S-2056 Screen,3-Track Head Ke mark Aluminum GLASS TYPE 50 S-2057 Screen,3-Track Jamb Ke mark Aluminum RATING DWG#: REV.: A +/-50 PSF CWS-1150 1 B +/-65 PSF SCALE: SHEET 1:2 3 OF 11 22„ 40 16 r 17 �6n� 16 �flYIYhYII�W/[/[1 U'• tf 11 z 13 15 1i3„ (� 17-1 O D WINDOW SYSTEMS 1-63„ F 1900 SW 44TH AVE. 13 13 2n OCALA,FLORIDA 34474 WW W.CWS.CC 2-Track Sill-6161 6 „ —7„ 4�, „ „ H-324 8800 PVC 16J” SLIDING GLASS (� (� 0 I 3L9F" SIII Riser-2060 DOOR-IMPACT ❑❑❑o❑❑❑, El o8 32 ❑ 6063-T6 �� Sill Riser-2062 w 3-Track Sill-6163 Panel Head/Sill/Stile-6166 6063-T6 o 1 F„ Astragal-6167 P-Hook-2063 0 6063-T6 m m ��0 0 [�L4 2 36 S„ Z O 0 O ° D - 32 � „ 2 5„ L� D' ❑❑❑❑ ❑❑❑°❑❑❑°❑❑❑° -� t 2" w z �6 4-Track Sill-6165 I to a �Reinf.,Ext-Interlock Reinf.,Frame-2069 2071 6063-T6 W v L 5j' ooc I 2 „ 41 6005-T6 Q o 14 Lock Stile-2086 P-fHook Adaptor-2065 s O 5 " 6063-T6 1 1 F z 13„ g 119 0 0 2 34 36 ,pN RE ',i i , 2tl❑LI❑D❑❑❑d8 r " —� i�" 7 ������10REt4• obi ❑ ❑ ❑ L I—� „ ��.��°��C E NS� Pym'. FLI 2-Track Head/Jamb-6160 4„ 1„ 1�' v: No 58201 :�-P Cover,Ext Reinf.& HGokstrip-6172 11 T STATE OF Cover,Interlock-6169 Reinf.,Interlock-1769A Reinf.,Lock Stile-1775 wopj U 136 6005-T6 6005-T6 ''',��SSCONA37 �NO��,, 15, Ill 111jiffI11111110%r 41 �0❑❑❑11 El �❑08 32 I 2 g" 35 8 3-Track Head/Jamb-8162 9 11/21/2016 Cover,Sill Track-6171 oiler Track Insert-2064 LUCAS A.TURNER,P.E. 6063-T5 FL PE#58201 10 „ 1239 JABARA AVE. VEJ 7 2j„ NORTH PORT,FL 34288 PH.941ION: 74 3tlSHEET DESCRIPTION:❑a❑❑❑o❑❑❑o❑❑❑Ll ok 3z° h_ I EXTRUSIONS *1 i„ 1� 4. Reinf.,HD Interlock-2111 4-Track Head/Jamb-6164 T— 6005-T6 DRAWN BY: . DATE: 12 BLZ 05/06/16 IG Glazing Bead-6170 Reinf.,Astragal-2068 DWG#: REV.: Track Filler-6175 6005-T6 CWS-1150 1 SCALE: SHEET NOTE:ALL EXTRUSIONS ARE RIGID PVC UNLESS OTHERWISE NOTED. 1:2 4 OF 11 43 12" 28" VVIND �//�('�J/ 1900 SW 44TH AVE. 16 1 OCALA,FLORIDA 34474 e- WW✓V.CWS.CC T— Screen,1-Track Sill-2052 =ij Screen,1-Track Head-2050 O O O16" 8800 PVC 4i_5 SLIDING GLASS 16' —I as T— 4s 22 1 DOOR-IMPACT 18 116 1.. 1--- 16 1_ — — 18^ e' WINDOW SYSTEMS LTJ 1900 SW 44TH AVE. OCALA,FLORIDA 34474 W1MN.CWS.CC 45„ 8800 PVC 9 H-2060 n l 1 110 H-2062 SLIDING GLASS ❑ � O ❑ 0 O ❑ O ❑ Q O O � c � ❑ Q ❑ O 0 DOOR-IMPACT R❑❑❑Flo-C]❑❑❑a N0❑❑❑0❑❑❑0❑❑❑Oa `�°❑❑❑❑D❑❑❑❑❑11 11❑❑❑°❑� iL 2T Sill w/Riser 3T SNI w/Riser 4T Sill w/Riser o O z Z LL. 0 T z O 0 a Flo 9 ax ❑ ❑ 0 0 0w �0❑❑❑�❑❑❑OCA �0❑❑❑'CIE] ❑❑10� ¢ 0 Z 2T Sill w/1T Screen 3T Sill w/1T Screen 1-1 12 No 58201FF 0t STATE 9 9 �enrrna�t� �]0❑❑❑O❑❑❑0❑❑❑CCI X113 0❑❑❑0❑❑❑11 13 ❑❑Oa ' 11/21/2016 3T Sill w/2T Screen 4T Sill w/1T Screen LUCAS A.TURNER,P.E. FL PE#58201 16: ^ 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION; (� TRACK WIDTHS (1 DRAW DTE: BLZ 05 /06/16 DWG 9: REV.: 0 ❑ °�0❑❑ 0 ❑ oCWS-1150 1❑ ❑ ❑❑❑❑ ❑❑❑ U SCALE: SHEET 4T Sill w/3T Screen 1:2 60F11 ANCHORS @ rL P-HOOK 6" 4" TF-P- PANEL-TYP ANCHORS IORS MAX 6"MAX.TYP. TYW• 4" " WEDGE TY NPIOFANEL — VWIN(JDtlO�WLKSYSTEMS TYP. � 1900 SW 44TH AVE. i i i i i iOCALA,FLORIDA 34474 I II I WWW.CWS.CC II 12"MAX.O.C. MAX I II — 8800 PVC I II I SLIDING GLASS L I II I DOOR-IMPACT I II I -- _ a z I II I ? o 0 II MID-SPAN I d F I II OF I I PANEo L o 2 Q I=> I • I II I °Z• o o. I •I•L/ o � I' I I• I I Il o ,��� PNOREIV FIXED PANEL CLIPS JVp'• NOTES: 'CIRCLED ANCHOR LOCATIONS REQ'D ONLY IN WOOD INSTALLATIONS..(SEE NEXT,SHEET FOR DETAIL) 1.INSTALL TWO ANCHORS AT EACH INSTALLATION LOCATION SEE LAYOUT DETAILS ON SHEETS 8&9 EXCEPT FOR 2T SILL&WOOD INSTALLATION LOCATIONS.SEE SPECIAL LOCATIONS AND SPACING FOR 2T SILL fl ( ) ^9i STATE OP .�W: (SHEET 8).INSTALL ONE ANCHOR AT EACH WOOD INSTALLATION LOCATION(CIRCLED). SILL ANCHOR SPACING SAME AS HEAD FOR 3T AND 4T. INSTALL ONE ANCHOR AT EACH LOCATION IN HOOKSTRIP. 'O . •�u@ 2 SHIM HSTS REQ EACH HIGH INSTALDENSITLATION PLASTIC OR BE WOOD SHIMS ARE ANCHOR IINGLOAD BEARING R. S. MAX AOWED.ABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16"IS PRESENT. LOAD BEARING SHIMS SHALL BE '��is�ONA Ea�``� 3,ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 10. ZZ 4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST 11/21/2016 BE PROTECTED TO PREVENT REACTION. LUCAS A.TURNER,P.E. FL PE#58201 5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM 1239 JABARA AVE. SPECIFIED IN TABLE 1,SHEET 10. NORTH PORT,FL 34288 PH,941-380=1574 6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE. SHEET DESCRIPTION: INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE, ANCHOR SCHEDULE AND NOTES 7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN-ALL FASTENERS:3"FOR SOLID CONCRETE,6"FOR CMU MASONRY,1"FOR WOOD AND METAL. DRAWN B DATE: 8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. BLZ 05/06/16 SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLE1,SHEET 10. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. DWO r: REV.: 9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: CWS-1150 1 FMA/AAMA 100(FIN WINDOWS),FMA/AAMA 200(FLANGE WINDOWS), FMAIWDMA 250(BOX WINDOWS),FMA/AAMAIWDMA 300(EXTERIOR DOORS) SCALE: SHEET 1:20 7 OF 11 i E INTERLOCKS E \ YASTRAGAL 21"O.C.MAX 'wago.m. PANEL P-HOOK s„TYP. TYR WINDOW SYSTEMS s"TYP. WDTH 3"TYP. I- 3"TYP. 1900 SW 44TH AVE. OCALA,FLORIDA 34474 W W W CWS.CC 0 ° s"ltyp. 8800 PVC SLIDING GLASS WOOD SUBSTRATES ##'_1DOOR-IMPACT p I 2T SILL oNLY. 2T JAMB TYP. � ti m F INTERLOCKS ti ASTRAGAL PANEL P-HOOK 6.,7YP. 21" C.MAX �6"TYP.�i WIDTH f--4"TYP.--i 4"TYP � TYP. m m O z Z LL O UJI zLLI 0 V0 3"TYP. 6"TYP. 3, 2 p a, TYR w a o (off o o WO y ❑ W Q O }"TYP. .. 1�� Z WOOD SUBSTRATES - TYP. TYP. ONLY 3T JAMBS �����NOREIti�����i 3T SILL TYP. •�5 P e No 58201 INTERLOCKS =*; �s TYP. WIDTH ASTRAGAL P-HOOK 6"TYP. 21"O.C.MAX �9��• STATE OF 4.,TYP. 4"TYP. TYP. .,(O R 1 Q P••��.`,� ,i,�Ss��NA� ° z� CO)--- s"TMp' 11/21/2016- 4 TVP LUCAS A.TURNER;P.E. 4 j"TYP. FL PE#58201 1239 JABARA AVE. 0 0 o I o NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: ANCHOR PATTERNS WOOD SUBSTRATES—J (JAMB&SILL) ONLY Typ, 4T SILL 4T JAMB TMril P DRAWN BY-.' DATE: BLZ 05/06/16 D G#: REV.: CWS-1150 1 NOTE:¢=CENTERLINE OF INTERLOCK OR ASTRAGAL So ' SHEET CIRCLED ANCHOR LOCATIONS REO'D ONLY IN WOOD INSTALLATIONS. 1:5 8 OF 11 -- INTERLOCKS -- ASTRAGAL CNEDOW, HOLE PATTERN P-HOOK SYSTEM$ 6"TYP.----{ PANEL FOR ANTI-LIFT 1900 SW 44TH AVE. _ BLOCK ANCHORS F---4"TYP--1 - WIDTH OCALA,FLORIDA 34474 W WW.CWS.CC 0 0 o 8800 PVG o) o SLIDING GLASS - - 1'-TYP DOOR-IMPACT "TYP. WOOD SUBSTRATES _-- - ^TYP. _ - --- - 2T-HEAD__ 4"TYP _-_ ONLY - - - -_ ---- . INTERLOCKS O f HOLE PATTERN ASTRAGAL 6"TYP. PANEL FORANTI-LIFT p-HOOK m m WIDTHBLOCKANCHORS Fes-4"TYP. 4"TYP. O y Z LL O_ u. 0 o LUy wlw Z W O yd0 s 0 TYP. Lu cn 0 W 0 o O Q 0 1-'TYP Z WOOD SUBSTRATES--/ ��```NOREh�����i 3T HEAD ONLY ,.� P .......... G�Qy f INTERLOCKS PANEL HOLE PATTERN ASTRAGAL '9't STATE OF I 6„TMP WIDTH BFOL.ANCHORS P-HOOK �--4”TYP. 4"TYP, ii��Cs•.<,O F1. �i,��S��N•Ary��t�`�� I 11/21/2016 I •o o TYP4 p'. LUCAS A.TURNER,P.E. -' FL PE#58201 1239 JABARA AVE. 0 0 0 0 0 0 NORTH PORT,FL 34288 PH.941-380-1574 0 SHEET DESCRIPTION: 1"TYP ANCHOR PATTERNS (HEAD) WOOD SUBSTRATES DRAWN BY: DATE: ONLY BLZ 05/06/16 4T HEAD DWG#: REV.: CWS-1150 1 NOTE:q=CENTERLINE OF INTERLOCK OR ASTRAGAL SCALE: SHEET CIRCLED ANCHOR LOCATIONS REQ'D ONLY IN WOOD INSTALLATIONS. 1:5 9 OF 11 2 TRACK HEAD ANCHORAGE MIN.EDGE DIST. 1/4"MAX WINDOW SYSTEMS LLQ SEE TABLE 1 SEE LAYOUT ON BHT 9 1900 SW 44TH AVE. 39,FRAME INSERT REQ'D AT OCALA,FLORIDA 34474 ALL FRAME ANCHOR LOCATIONS 39,FRAME INSERT REQ'D WVNN.CWS.CC �� AT ALL FRAME ANCHOR w LOCATIONS SUBSTRATE BY OTHERS MIN.EMBEDMENT O 8800 PVC SEE TABLE 1 SEE TABLE 1 SLIDING GLASS _ PERIMETERSEALANT �� o SEELAYOUT DOOR-IMPACT BYINSTALLER G❑ ON BHT 6 INSIDEANDOUT i"MAX. SHIM a m w Icc MIN EDGE DIST p oU SEE TABLE 1 PERIMETER SEALANT I m M INTERIOR COMPLIANT WITH AAMA 800 -1 BY INSTALLER INSIDE AND OUT OLL Z INSTALLATION ANCHOR Z SEE TABLE 1 SUBSTRATE BY OTHERS MIN EMBEDMENT 0: SEE TABLE 1 SEE TABLE 1 W Z a F SEALANT BETWEEN SILL U) 0_ RISER AND FRAME BY B HORIZONTAL SECTION 0 p INSTALLER 9 2 TRACK JAMB ANCHORAGE 0 W 0 o u o PERIMETER SEALANT =9 CD[:] g❑❑^8a O BY INSTALLER I� INSIDE AND OUT _ DO NOT COVER Z HOLESIN.EMBEDMENT uncap SUE STRATE SEE TABLE 1 ,% PNOREII,rT,le , BY OTHERS `� E NSF SEE TABLE 1 ,` Z"-t Nc 58201 MIN.EDGE DIST. 39,FRAME INSERT REQ'D AT SEE TABLE 1 ALL FRAME ANCHOR LOCATIONS O. STATE OF :41 Ai Z /-A"\VERTICAL SECTION P; C, 9 2 TRACK SILL ANCHORAGE rrr640NAL p% PERIMETER SEALANT COMPLIANT WITH AAMA 800 �Z- BY INSTALLER INSIDE AND OUT INSTALLATION ANCHOR SEE TABLE 1 11/21/2016 MIN.EDGE DIST. LUCAS A.TURNER,P.E. EE TABLE 1 FL PE#58201 1239 JABARA AVE. SUBSTRATE BY OTHERS MIN.EMBEDMENT NORTH PORT,FL 34288 TABLE 1:APPROVED INSTALLATION FASTENERS SEE TABLE 1 SEE TABLE 1 PH.941-380-1574 SUBSTRATE TYPE ANCHOR TYPE MIN.EMBEDMENT MIN.EDGE DIST. SHEET DESCRIPTION: CONCRETE 2.0 KSI MIN. 1/4"ITW TAPCON 1-12" 4" ez"VZ INSTALLATION DETAILS CONCRETE(2.85 KSI MIN.) 114"ELCO ULTRACON 1-314" 2-1/Z' HOOKSTRIP 2 TRACK 2X MIN.SOUTHERN PINE(G---0.55) 114"ITW TAPCON OR 1-3/8" 7/8" ELCO ULTRACON a'MAX.SHIM DRAWNBY: DATE: 2X MIN.SOUTHERN PINE(G=0.55 #12 WOOD SCREW 1-3/8" 7/8" BLZ 05/06/16 16 GAUGE(0.060")MIN. 012-14 HIL11 KWIK-FLEX OR ITW FULLTHREAD STEEL STUD(33 KSI YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.060" 1/2 DWG#: RE .: 1/8"ALUM.(6063-75 MIN.)OR #12 GRADE 5 SELF-TAPPING/ FULL THREAD 9 HORIZONTAL SECTION CWS-1150 1 1/8"STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125' HOOK STRIP SCALE: SHEET HOOKSTRIP OR JAMB FRAME ONLY: 114"ELCO ULTRACON 1-3/4" 2-1/2" 1:3 10 OF 11 HOLLOW OR GROUT-FILLED CMU ASTM C-90 3 TRACK HEAD ANCHORAGE 1/4"MAX SEE LAYOUT 39,FRAME INSERT REQ'D AT INTERIOR �EJ,�ICLL MIN.EDGE DIST. ON SHT 9 ALL FRAME ANCHOR LOCATIONS WINDOW SYSTEMS SEE TABLE 1,SHT 10 39,FRAME INSERT REQ'D �� 1900 SW 44TH AVE. SUBSTRATE LO ATIONSME ANCHOR --- BY OTHERS LOCATIONS OCALA,FLORIDA 34474 SEE TABLE 1,SHT 10 MIN.EMBEDMENT a NNWJ•CWS.CC SEE TABLE 1,SHT 10 PERIMETER SEALANT 8800 PVC BY INSTALLERtJJB❑ �D��B(] DB❑ 6 SLIDING GLASS INSIDEANDOUT 4 MAXJJJJ SHIM a� SEE ON HT8T DOOR-IMPACT INSTALLATION ANCHOR _ _ INTERIOR - SEE TABLE 1,SHT 10 = - SEALANT BETWEEN SILL - - -- RISER AND FRAME BY INSTALLER PERIMETER SEALANT I=) O O MIN EDGE DIST m m BY INSTALLER O O o SEE TABLE 1 SHT 10 DO INSINOT COVERT R � OF]❑ ❑ ��� PERIMETER SEALANT _� L Z WEEP HOLES COMPLIANT WITH AAMA 800 z 0 SUBSTRATE MIN.EMBEDMENT BY INSTALLER INSIDE AND OUT w SEE TABLE 1,SHT 10 BY OTHERS SUBSTRATE U SEE TABLE 1,SHT 10 BY OTHERS MIN EMBEDMENT d H 39,FRAME INSERT SEE TABLE 1,SHT 10 SEE TABLE 1 SHT 10 u) (L MIN.EDGE DIST. SEE LAYOUT ON SHT 8 REQ'D AT ALL FRAME LLJ O SEE TABLE 1,BHT 10 ANCHOR LOCATIONS �HORIZONTAL JAMB ANCHORAGE ❑ U) D VERTICAL SECTION 10 3 R 1/4"MAX ¢ O 10 3 TRACK SILL ANCHORAGE INTERIOR Z 4TRACK HEAD ANCHORAGE 39,FRAME INSERT 39,FRAME INSERT REQ'D MIN.EDGE DIST. SEE LAYOUT REQ'O AT ALL FRAME AT ALL FRAME ANCHOR `���t`p,NORE SEE TABLE 1,SHT 10 LOCATIONS �� 5.•..........C E N..'•G �i ON SHT 9 ANCHOR LOCATIONS MIN.EMBEDMENT ,6P• SFS•.y 4 SUBSTRATE SEE TABLE 1,SHT 10 ❑ �; No 58201 ••:�� BY OTHERS 1�9 -ro. SEE TABLE 1,SHT 10 ir u ^"'0'.; STATE OF . u, PERIMETER SEALANT SEE LAYOUT ,n ,•o(O R 1 O P�:�# INSIDE AND UT G❑0�� OG�I, []C "MAX. L❑ ON SHT B ' /ri110101111110% SHIM INSTALLATION ANCHOR INTERIOR 11/21/2016 SEALANT BETWEEN SILL SEE TABLE 1,SHT 10 LUCAS A.TURNER,P.E. RISER AND FRAME BY FL PE#58201 INSTALLER MIN EDGE DIST 1239 JABARA AVE. PERIMETER SEALANT Q 8 �� SEE TABLE 1 SHT 10 NORTH PORT,FL 34288 BYINSTALLER D O O O oP PH.941-380-1574 INSIDEANDOUT �$❑O ❑❑��❑� ❑�� SHEET DESCRIPTION: DO NOT COVER WEEP HOLES MIN.EMBEDMENT INSTALLATION DETAILS SUBSTRATE SEE TABLE 1,SHT 10 PERIMETER SEALANT 3&4 TRACK BY OTHERS COMPLIANT WITH AAMA 800 BY INSTALLER INSIDE AND OUT DRAWN BY: DATE: SEE TABLE 1,SHT 10 SUBSTRATE BLZ 05/06/16 39,FRAME INSERT BY OTHERS MIN EMBEDMENT MIN.EDGE DIST. SEE LAYOUT SEE TABLE 1 SHT 10 Dwc a+: REV.: SEE TABLE 1,SHT 10 ON SHT 8 REQ'D AT ALL FRAME SEE TABLE 1,SHT 10 ANCHOR LOCATIONS G HORIZONTAL SECTION CWS-1150 1 • E VERTICAL SECTION 10 4TRACK JAMB ANCHORAGE SCALE: SHEET 10 4 TRACK SILL ANCHORAGE 1:3 11 OF 11 i w . _r r t '3 (ir4ilfl�i` V, BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Fads Publications FBC Staff BCIS Site Map - Lino Search ba i. Product Approval «� r ( -;I, N°6 USER:Public User Product Aooroval Menu>Product or Application Search>Aoolication Ust>Application Detail - FL# FL5823-R7 t= '_.•tee a,r,_ 1 PP Type Application T e Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenue Ocala,FL 34474 (352)368-6922 Ext 255 sbrooks@cws.cc Authorized Signature Stephen Brooks sbrooks@cws.cc Technical Representative Erin Koss Address/Phone/Email 1900 SW 44th Ave. Ocala, FL 34474 (352) 368-6922 Ext 291 ekoss@cws.cc Quality Assurance Representative ]ay Lathrop Address/Phone/Email 1900 SW 44th Ave. Ocala,FL 34474 (352)368-6922 Ext 291 jlathrop@cws.cc Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lucas A.Turner the Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract E4Piration Pate07y2fF2(120 � Validated By Steven M. Urich, PE Validation Checklist-Hardcopy Received Certificate of Independence FL5823 R7 COI Eval�eo CWS-155C(SH-8100.Im act).p_df Referenced Standard and Year(of Standard) Standard Year HAMA/WDMA/CSA/iQl/I.S.2/A440-05 2005 ASTM E1300-04 2004 ASTM E1886-02 2002 URNURNER1239 Jabara Ave. ER North Port,FL 34288 ENGINEERING& Ph. 941-380-1574 CONSULTING,INC. FBPE C.O.A. 929779 Evaluation Report 155C April 18,2015 Product Description: Series 8100 PVC Single Hung,Large Missile Impact,53 1;!/8"x 76"unit size at up to+/-67.5 PSF,36"x 62"unit size at up to+67.5/-75 PSF,7/8"Insulating Glass consisting of 1/8 Annealed or Tempered outboard lite —Air—5/16 Laminated(1/8Ann-.090PVB-1V8Ann)inboard lite Manufacturer: Custom Window Systems,Inc. 1900 SW 44`x'Ave,Ocala,FL''34474 Statement of Compliance: This report evaluates the above-listed product penthe requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with they requirements of the 5h Edition(2014)Florida Building Code including the High Velocity Hurricane Zone. The product testing standards performed are outlined below. Technical Documentation: 1) This report,prepared by Lucas A.Turner,P.E.,at 1239 Jabara Ave.,North Port,FL 2) Approval drawing CWS-155C,signed and sealed by Lucas A.Turner,P.E. 3) Test Report NCTL-210-3668-1,-IA,-2,-2A,3669-1,-1A,-2,and-2A,by National Certified Testing Laboratories,Orlando,FL,signed and sealed by Gerard J.FerraraI,with testing performed: TAS 201,202,203 1994,ASTM E 1886, 1996 2002/2005,and AAMA A440 2005 4) Supplemental Calcs.to support CWS-155C,signed and sealed by Lucas A.Turner,P.E. Installation: Units must be installed according to approval document CWS-1550. Limitations of Use: This product: • May be used in O/X configuration in sizes,design pressures,and with max.glass DLO heights as shown in CWS-155C Is impact resistant and does not require the use of shutters • May be used in the High Velocity Hurricane Zone • Requires 7/8"Insulating Glass consisting of 1/8 Annealed or Tempered outboard lite(Tempered required above 30 ft in HVHZ) —Air—5/16 Laminated(1/8Ann-.090PVB-1/8Ann)inboard lite • Requires Dupont PVB Interlayer per Miami-Dade N.O.A. 13-0129.271 • Requires Quanex(Mikron).white rigid PVC framing per Miami-Dade N.O.A. 12-1017.021 t I have evaluated the interlayer,and framing materials in these Dupont and Quanex NOAs and find that they comply with the requirements of the 5`"Ed.(2014)Florida Building Code for use in this product. Certification of Independence: I do not have,nor do I intend to acquire,norwill I acquire,a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have,nor do I intend to acquire,nor will I acquire,a financial interest in any other entity involved in the testing or approval process of this product. ORE t• No 58201 '-P Z 7 4/18/2015 Lucas A: Turner P.E. :9'• sraTs of ' �'' FL PE#58201 ........ \`�, Lucas A. Turner 22:13-04:00 SINGLE HUNG - LARGE MISSILE IMPACT GENERAL NOTES: SHOWN W/DIFFERENT OPTIONS 1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED WINDOW SYSTEMS TO COMPLY WITH THE FLORIDA BUILDING CODE(FBC),CURRENT EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ)AND 1900 SW 44TH AVE.` IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED OCALA,FLORIDA 34474 IN ASTM E 1996 PER THE FBC. W WW.CWS.CC 54 3/8" 2.GLAZING OPTIONS:(SEE SHEET 2) 8�QQ PVC OVERALL FLANGE WIDTH 3Z 3.CONFIGURATIONS:"O/X". 531/8'MAX.UNIT WIDTH OVERALL FLANGE WIDTH SINGLE HUNG 481566 4.DESIGN PRESSURE RATING: IMPACT GLASS DLO -NEGATIVE DESIGN LOADS BASED ON,TESTED PRESSURE AND 3S" GLASS TABLES ASTM E-1300.04. MAX UNIT WIDTH -POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE,WATER n T c 3113L15! INFILTRATION TEST PRESSURE AND GLASS TABLES a m n til. 771/4" I I GLASS DLO ASTM E-1300.04. c o c o MAX. OVERALL I I A 5.ANCHORAGE:THE 33 1/3%STRESS INCREASE HAS NOT BEEN USED FLANGE -- - IN THE DESIGN OF THIS PRODUCT.SEE SHEET 6 FOR ANCHOR � W p } HEIGHT DETAILS. WINDLOAD DURATION FACTOR Cd-1.6 WAS USED FOR WOOD w H ¢ m O 3315L16 -- ANCHOR CALCULATIONS. Z 63 1/4' GLASS 1 I I LL W 76' I I DLO FLANGE I I 6.PRODUCT APPROVED FOR IMPACT RESISTANCE. THE IMPACT ROTARYo ccc c I I HEIGHT O LOCKS ARE INTENDED TO BE LEFT UNLATCHED DURING NORMAL N N m Z W HEIGHT B U IT B GLASS OPERATION BUT MUST BE ENGAGED PRIOR TO EXPOSURE TO ¢ ¢ p cc 6 DLO HURRICANE WINDS AND FLYING DEBRIS,MAX a a a a 11 UNIT 7.ALL FRAMES AND VENTS FULLY WELDED.SMALL JOINT SEAM SEALANT F ¢ B HEIGHT I I USED AT FIXED MEETING RAIL AND JAMB. o 0 o m 31ltam 6 I 8.SERIES/MODEL DESIGNATION SH-8100. > > > o MAX C 34_ SASH I " 6 GLASS 3.0_5/16 9.THE DESIGNATION X AND O STAND FOR THE FOLLOWING: V m ¢ Z HEIGHT Jt D MAX X=OPERABLE SASH,O=FIXED SASH SASH x ...0 ,�punrnrrrr 6 HEIGHT GLASS 10.SECTION CALLOUTS APPLY TO ALL ELEVATIONS INA SIMILAR ���`PNORE.. T'�4 I I I I DLO ,. LOCATION. ��Gp.�.��CENSF•;'p,L�,'. C 11.EXTERNAL WEEP SLOT=1/4"x 1-1/4"LOCATED 4"FROM BOTH ENDS. v:� No 58201 C q A 12.SWEEP LOCKS INSTALLED ON WINDOWS OVER 36"x 62". 5 p; D: 6 09 STATE OF .+LZ GLASS DLO GLA DLO__j ,0i�O'cC�`•% k R�pP-., /, 4911116" 31_sLto_ Lucas A.Turner �'%SS�oNA1-E;;�``� MAX.SASH WIDTH MAX SASH WIDTH 20155-04-09 rrrrrrrrr�� 12:43-04:00 ;zf-n 419/2 015 LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: DESIGN PRESSURE GENERAL NOTES AND LOCATION MAX. UNIT SIZE IMPACT RATING TABLE OF CONTENTS RATING ELEVATIONS .....1_ NON-HVHZ +/-65 PSF DRAWN BY: DATE: GENERAL NOTES&ELEVATIONS 53-1/8„X 76„ ADE 06/10/08 GLAZING DETAILS...............................2 HVHZ +/-67.5 PSF DWG#: REV.: SECTION VIEWS&ALT.FRAME........3 LARGE MISSILE IMPACT CWS-155 C EXTRUSIONS&B.O.M.........................4 NON HVHZ +65/-75 PSF SHEET ANCHOR SCHEDULE&NOTES..........5 _ 36„X 62„ SCALE; INSTALLATION DETAILS.....................6 HVHZ +67.5/-75 PSF 1:1 1 OF 6 W131"OVERALL INSULATED GLASS- 7/8"OVERALL INSULATED GLASS t,® •rJ"��jj 1/8"ANNEALED 1/8"ANNEALED WINDOW SYSTEMS 1900 SW 44TH AVE. 7/16"AIRSPACE 7/16"AIRSPACE OCALA,FLORIDA 34474 W W W.CW S.CC 5/16'LAMINATED GLASS 5/16"LAMINATED GLASS 1/8"ANNEALED. 1/8"ANNEALED - .8100 PV.0 .090"1 INT ERLAYER BY DUPONT .090"PVB INTERLAYER BY DUPONT SINGLE HUNG 1/8"ANNEALED 118"ANNEALED IMPACT DURASEAL BY TRUSEAL DURASEAL BY TRUSEAL 18 PURFECT GLAZE"HOR SIKAFLEX 552 18 PURFECT GLAZE"H"OR SIKAFLEX 552 u> r c T o 0 o H 1 1/2'GLASS BITE 1/2"GLASS BITE o r o 0 YLu 38 w0y w F ¢ m U) w z T m LL T 0 4 a O U > N N IL Z w w w O a a. a a � w w ¢ GLASS TYPE A m GLASS TYPE A SASH LITE > > > 0 FIXED LITE v m ¢ O z � p1DREW "I 7/W 7/8"OVERALL INSULATED GLASS 7/8"OVERALL INSULATED GLASS �5 P,.....,,• —1/8°TEMPERED —1/8"TEMPERED ����P�•�\GEIVSF.,�Q2��� 7/16"AIRSPACE 7/16"AIRSPACE _ :�4;� No 56201 •':n� 5/16"LAMINATED GLASS 5/16"LAMINATED GLASS ' iz 1/8"ANNEALED - 1/8"ANNEALED Z�. STATE OF .�� 0ANNEALED 90 LAYER BY DUPONT 10/8" ED 1 INTERLAYER BY DUPONT �iSs+O RA. DURASEAL BY TRUSEAL DURASEAL BY TRUSEAL 18 PURFECT GLAZE"H"OR SIKAFLEX 552 18 PURFECT GLAZE H'OR SIKAFLEX 552 / LUCAS A.TURNER,P.E. - - 1 1/2°GLASS BITE 1!2'GLASS BITE - FL PE#58201 1239 JABARA AVE. 36 pi NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: 4 GLAZING DETAILS ' DRAWN BY: DATE: ADE 06/10/08 DW G A: GLASS TYPE B CWS-155 C GLASS TYPE B SASH LITE TCALE. SHEET FIXED LITE 1:1 20F6 INTERIOR ���®�• WINDOW SYMMS 3 21 19 10 39 11 21 15 3 ` 1900 1900OCASS FLORIDA 34474 W 44TH AVE.' WWW.CWS.CC 41 41 8100 PVC SINGLE HUNG IMPACT 21 o 0 o Fw-. 20 12 20 26 0 o SECTION VIEW B-B 2 w p } NOTE:LEFT SIDE SHOWS FIXED SECTION VIEW, N RIGHT SIDE SHOWS SASH SECTION VIEW. LL LL W O 30 a o mU (D _. NN lL Z 12 ¢ a[ S O cc 38a a a a 5 31 29 0 0 0 0 o-` w 7 INTERIOR 4 32 8 Um ¢ Z 48 19 ,%��P�Pr1DRE v: No 58201 •'�'I� e 19 9 STATE OF :4U 25 LUCAS A.TURNER,P.E. 40 FL PE#58201 o __ o o 's 1239 JABARA AVE. 2 41 NORTH PORT,FL 34288 PH.941.380-1574 SECTION VIEW C-C SHEET DESCRIPTION; SECTION VIEW A-A SECTION-VIEWS ALTERNATE FIN FRAME SWEEP LOCK REQUIRED NO SWEEP LOCKS ALLOWED FOR SIZES OVER 36"x 62". DRAWN BY: DATE: FOR UNITS 36"x 62"AND UNDER. — - ADE .... 06/10/08 DWG N: RE ITEMS NOT SHOWN FOR CLARITY: CWS-155 C 22,27-28,33-37,43-45 - - - SCALE: SHEET 1:2 30F6 PARTS LIST FRAME CORNER ITEM PART# DESCRIPTION MATERIAL VENDOR 31/a• CONSTRUCTION 1 H-6031 Frame Head,Fig,Single Hung PVC MIKRON WINDOW SYSTEMS LpL(ll%J 2 H-6031 Frame Sill,Fig,Single Hung PVC MIKRON 1 15116" 3 H-6031 Frame Jamb,Fig,Single Hung PVC MIKRON OCA 2 CALA 1 2 3/16" , LTH AVE. FLORIDA 34474 4 H-1836 Alum.Fixed Meet.Rail ALUMINUM KEYMARK 3 s WWW.CWS.CC 5 S-6063 Fixed Rail Cover PVC MIKRON e 6 H-6027 Sash Top Rail PVC MIKRON 211/16" 1 5/8" fIQ 1 F71 7 H-1497 Reinforcement forSTR ALUMINUM KEYMARK 1/16LIs 8100 PVC 8 H-6028 Sash Bottom Rall PVC MIKRON � ll 1/16^ CORNER WELD SINGLE HUNG (ALL SIDES) 9 H-1699 Reinforcement for SBR ALUMINUM KEYMARK 1:8 10 H-6004 Sash Side Rail PVC MIKRON PVC FRAME FLANGE-6031 PVC SASH BTM.RAIL-6028 PVC SASH TOP RAIL-6027 IMPACT 11 S-1498 Reinforcement for SSR ALUMINUM KEYMARK 12 S-6064 Glazing Bead PVC MIKRON m o 13 P-3118 Keeper,Sweep Lock ZINC SULLIVAN a �n Q lii 14 P-3541 #8 x 1/2",Pan Head,Tek STEEL FASTENAL 2 ;C41: 0 o Q 15 P-4632 Sweep Lock ZINC SULLIVAN 31/s" — oro 0 16 P-4633 Barrel Fastener STEEL FASTENAL I q7 1 1/2" w o } 17 Block&Tackle Balance STEEL CALDWELL 1 3/16• w F ¢ m lyl 18 Purfect Glaze"H"or Sikaflex 552 SILICONE HENKEUSIKA10 4 SCREWED TOGETHER WITH Z FIXED MEETING RAIL m v U O 19 Sash SEE SHEET 2 GLASS CARDINAL I OUTERFRAME m Co W O 20 Fixed SEE SHEET GLASS CARDINAL 1/16• _ 3 9/16" 1 5/8" 2 1/8" 1/16" 1:a v o ) U) 21 P-3429 Wstp.,0.270 x 0.187 back FinSeal NYLON ULTRAFAB N $ m z > 22 P-4638 #8 x 2-1/2 PH Mod.Truss,Type A,TEK STEEL FASTENAL li q 1/16" w w w D 23 #10 x 1 1/2"Panhead SMS STEEL FASTENAL II o 0 o a 24 Flat Washer STEEL FASTENAL _1"_ L w CC 25 S-6014 Screen Catch PVC MIKRON PVC SASH SIDE RAIL-6004 FIXED RAIL-1636 0 0 o co 0 26 S-6013 Screen Support PVC MIKRON a, > > o 27 P-4051 #8 x 1 1/4"Ph Fh TEK,Wht. ZINC FASTENAL PVC FRAME FIN-6048 28 P-3748 #6 x 0.625"Quad Fh TEK,Wht. ZINC FASTENAL U m ¢ z 29 P-3783 Impact,Lock STEEL INTERLOCK ,,%%JI,rr18111" 30 P-4069 Impact,Keeper STEEL INTERLOCK 1 5/16 s/16° ���0 PNDREW "I 31 P-4264 #8 x 3/4 FH PH w/#6 Head,TEK,Wht STEEL FASTENAL 1/2° 1 1/a° r1 Ila°�{ � E r�s•.Gp,, 32 P-3218 Screen Frame ALUMINUM ALLMETAL 42 i r.41 5/16° —33 P-3321 Screen Corner Key PLASTIC M&M 7!g^ n 26 1 5/16" :-. No 5820134 P-3228 Screen Spline RUBBER DAPA j 35 P-3581 Screen Cloth VINYL WIER1116" L1/16" v16° -ro: ae 36 P-3033 Screen Spring STEEL HURLEY PVC SCREEN CATCH-6013 PVC FIXED RAIL COVER-6063 PVC SCREEN SUPPORT-6014 �9 STATE OF :4/+' P 9 PVC SASH STOP-6025 'O .40 37 P-3029 Screen Pull Tab STEEL HURLEY �',TF'.C O R tOP38 P-3352 Set.Blk. ' 39 P-3768 #8 x 5/8 Phil Pan/ 2 PanZinc RUBBER ZINC F RANK LO WE ONA I',�SS+ i 40 P-4479 Weepco%er PLASTIC M&M 41 P-3113 Screw Support RUBBER TEAM 3!q'L—� 3/4" 7 1/4 42 P-6025 Sash StopPVC MIKRON 3116' 7�I r—I4/9/201.9 � 9 i 1 43 P-3059 Sash Cam PLASTIC M&M 11 15/16 1116" 1^ 718" LUCAS A.TURNER,P.E. 44 P-3295 Take Out Clip STEEL SUMMIT T 1—V L v16" �_ FL PE 11158201 1/16" Cj:� 45 P-3342 Seam Sealer SILICONE SCHNEE 1239 JABARA AVE. NORTH PORT,FL 34288 46 P-3752 Hole Plug PLASTIC M&M REINF.S.B.R./S.S.R.-1498 REINF. BTM RAIL-1699 REINF.TOP RAIL-1497 PVC GLAZING BEAD-6064 47 H-6048 Frame Head,FIN,Single Hung PVC MIKRON PH.941-380-1574 48 P-4959 Wstp.,0.420 x 0.187 back NYLON ULTRAFAB SHEET DESCRIPTION: BOM AND EXTRUSIONS 1/2" 3/16"� DRAWN BY: DATE: r3 ADE 06/10/08 DWG#: REVZ SCREW SUPPORT-3113 CWS-155 . C NOTE:ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. SCALE: SHEET 1:2 40F6 J 15"MAX.O.C.(TYP.) WINDOW SYSTEMS' 6"MAX.(TYP.) 4"MAX.(TYP.) 8"MAX.O.C.(TYP.) 1900 SW 44TH AVE.' 6°MAX.(TYP.) 4"MAX.(TYP.) FT W ALA,FLORIDA L RI A 34474 4°MAX.(TYP.) 8°MAX.O.C.(TYP.) 4 6"MAX.(TYP.) "MAX..(TYP.) 6"MAX.(TYP.) 89��PVC B" -- -- SINGLE HUNG 14" Q MAX.O.C. O MAX.O.C. mP•) IMPACT (TYP.) I II I 8" 1013/16" I 0 I MAX.O.C. I O I � � a MAX.O.C. (TYP.) o 0 o H �ortraRAl� I I (TYP.) y r to a 1 o 0 O L.. 4"(TYP.) 1 v T -�rnra rua w N 0 a}D ul 4"(TYP.)J X 4"(TYP.)f I I I I 0 c) O Z X I I X m ¢ O Co I Q 4 N N lL LLI z - - - -- W W Ill 0 -- a a a d 0 w w 0: ANCHOR LAYOUT-(FLANGE) ANCHOR LAYOUT-(FIN) ANCHOR LAYOUT-(FLANGE) ANCHOR LAYOUT-(FIN) a a a y SIZES OVER 36"x 62" SIZES OVER 36"x 62" SIZES 36"x 62"AND UNDER SIZES 36"x 62°AND UNDER a a a W U m ¢ Z ,,,1�1{1114ry��,, PNOREKt 705, No i No 58201 •:�� *; * ;*=_ NOTES: '9STATE OF :4 �1 1.INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION.SILL ANCHOR SPACING SAME AS HEAD. 4�c�`• (O p%0 P N�,�� 2.SHIM AS REO AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX.ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16"IS PRESENT. LOAD BEARING SHIMS SHALL BE lot NA1 0% CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED. 3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,-SHEET 6. 419/90115 - _ - - 4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A_CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR-MATERIALS IN CONTACT WITH PRESSURETREATED WOOD-MUST- LUCAS A:TURNER;P.E: BE PROTECTED TO PREVENT REACTION. FL PE#58201 1239 JABARA AVE. 5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM NORTH PORT,FL 34288 SPECIFIED IN TABLE 1,SHEET 6. PH.941-380-1574 6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE. SHEET DESCRIPTION: INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND THE SUBSTRATE. ANCHOR SCHEDULE AND INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. NOTES 7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:3"FOR MASONRY,1"FOR WOOD AND METAL. DRAWN BY: DATE: 8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. ADE 06/10/08 SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. DWG#: REV.: CWS-155 C 9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: SCAL :- _ _ SHEET FMA/AAMA 100(FIN WINDOWS), NV FMA/AAMA 200(FLANGE WINDOWS), FMAIWDMA 250(BOX WINDOWS),FMA/AAMADMA 300(EXTERIOR DOORS) - _ 1:25 5 OF 6 MIN.EMBEDMENT Il TIl7C��® •L/�{/� TYPICAL HEAD ANCHORAGE SEE TABLE 1 SUBSTRATE ILIW.S6y In\("ISI"/�I BY OTHERS WINDOW SYSTEMS MIN.EDGE DIST. 1/4"MAX.SHIM SEE TABLE 1 MIN.EDGE DIST. SUBSTRATE SEE TABLE 1 SEE TABLE 1 BY OTHERS 1900 SW 44TH AVE. 1/4"MAX.SHIM SEE TABLE 1 FLORIDA 34474 SUBSTRATE BY OTHERS WWW.� WWW.CWS.CC SEE TABLE 1 1MIN.EDGE DIST. MIN.EMBEDMENT 4 SEE TABLE 1 PERIMETER SEALANT— SEE TABLE 1 $�00 PVC I11 BY NSTALLER INSTALLATION ANCHOR— I SINGLE HUNG INS DE AND OUT SEE TABLE 1 MIN.EMBEDMENT SEALANT BEHIND C� SEETABLEI IMPACT FLANGE BY INSTALLER 1/4"MAX.SHIM � LGH_ p1 00 pPERIMETER SEALANT o 0 o F PERIMETER SEALANT nn BY NSTALLER BY INSTALLER D Limo INSIDE AND OUT o o INSIDE AND OUT INSTALLATION ANCHOR �4 LL w O} SEALANT BEHIND SEE TABLE 1 w I- ¢ m INSTALLATION ANCHOR FLANGE BY INSTALLER SEALANT BEHIND C/) SEE TABLE 1 � FIN BY INSTALLER U 0 0 Z / o l HORIZONTAL SECTION �C� HORIZONTAL SECTION m LL cc W O 6 TYPICAL JAMB ANCHORAGE 6 TYPICAL FIN ANCHORAGE U HEAD AND SILL SIMILAR FOR FIN INSTALLATIONN N m Z w w w Lu a a a a w w ¢ U 1/4'MAX.SHIMa. aa.. as W SEALANT BEHIND FLANGE BY INSTALLER u U m ¢ Z BY RNSTALLEIMETER REALANT S E TABLE INSIDE AND OUT No 58201 '�'P SUBSTRATE BY OTHERS SEE TABLE 1 MIN.EDGE DIST. � SEE TABLE 1 VERTICAL SECTION % STATE OF 6 O�F � TYPICAL SILL ANCHORAGE Op1p9%'\=� �i0Olf Sf0NNA ��C�`� TABLE I:APPROVED INSTALLATION FASTENERS p FRAME TYPE SUBSTRATE TYPE ANCHOR TYPE MIN.EMBEDMENT MIN.EDGE DIST. D LUCAS A.TURNER,P.E. FLPE01 FLANGE CONCRETE 2.0 KSI MIN.) 3/16"ITW TAPCON 1-1/2" 1-1/8" # ( PERIMETER SEALANT 123939 JABARA RA AVE.A FLANGE HOLLOW OR GROUT-FILLED CMU(117 PCF MIN.) 3/16"ITW TAPCON 1" 2" BY INSTALLER NORTH PORT,FL 34288 FLANGE CONCRETE(2.85 KSI MIN.) 3/16"ELCO ULTRACON 1" 1.. INSIDE AND OUT � PH.941-380-1574 p1 HORIZONTAL SECTION FLANGE GROUT-FILLED CMU(ASTM C-90) 3/16"ELCO ULTRACON 1-1/4" 2-1/2" 6 BOX FRAME INSTALLATION SHEET DESCRIPTION: FLANGE 2X MIN.SOUTHERN PINE(G=0.55 3/16"ITW TAPCON 1 3/8" 7/8" HEAD AND SILL SIMILAR FOR BOX INSTALLATION OR ELCO ULTRACON INSTALLATION DETAILS FLANGE 2XMIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-3/8" 7/8" FLANGE REMOVAL NOTE:PARTIALLY OR FULLY REMOVING THE FLANGE, DRAWN BY: DATE: 16 GAUGE(0.060")MIN.STEEL STUD #10-16 HILTI KWIK-FLEXOR ITW FULL THREAD UP TO AND INCLUDING A BOX-FRAME APPLICATION IS ACCEPTABLE PROVIDED: FLANGE (33 KSI YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.060" 7/16" ADE 06/10/08 1/8"ALUM.(6063-T5 MIN.)OR #10 GRADE 5 SELF-TAPPING/ FULL THREAD MIN.1/4"FILLET OF CONSTRUCTION-GRADE ADHESIVE CAULK IS APPLIED Dw ##: RE .: C INSIDE AND OUT,FULL PERIMETER,BY INSTALLER. CWS-155 FLANGE 1/8"STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125" 7/16" PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS FIN 2X MIN.SOUTHERN PINE(G=0.55) #8 WOOD SCREW 1-1/2" 7/16" SHOWN FOR FLANGE WINDOWS. SCALE: SHEET 1:2 60F6 Leat BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map I Links I Search a F" Product Approval I t ' tj USER:Public User dbpr d" Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL16177-R1 :ja-;a7rbr , Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenue Ocala, FL 34474 (352) 368-6922 Ext 255 sbrooks@cws.cc Authorized Signature Stephen Brooks sbrooks@cws.cc Technical Representative Erin Koss Address/Phone/Email 1900 SW 44th Ave. Ocala, FL 34474 (352)368-6922 Ext 291 ekoss@cws.cc Quality Assurance Representative ]ay Lathrop Address/Phone/Email 1900 SW 44th Ave. Ocala,FL 34474 (352) 368-6922 Ext 291 jlathrop@cws.cc Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ;j v Evaluation Report-Hardcopy Received I Florida Engineer or Architect Name who developed Lucas A.Turner the Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 07/21/2020 Validated By Steven M. Urich, PE v Validation Checklist- Hardcopy Received Certificate of Independence FL16177 R1 COI EvalReo CWS-8128(SH-8100, NoSillAnch).odf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA/1g1/I.S.2/A440-08 2008 ASTM E1300-04 2004 ASTM E1886-05 2005 ASTM E1996-09 2009 PA TAS 201/202/203 1994 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/14/2015 Date Validated 04/21/2015 Date Pending FBC Approval 04/25/2015 Date Approved 06/22/2015 Summary of Products FL# Model,Number or Name Description 16177.1 SH-8100 PVC Single Hung SH-8100 PVC Single Hung Impact Resistant window. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16177 R1 II CWS-812B(SH-8100. IMP. NoSillAnch).Ddf Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: +70/-70 Evaluation Reports Other: SH-8100 PVC Impact, no sill anchors required. Safety FL16177 R1 AE DuPont PVB NOA 13-0129 27.pdf glazing required on outer lite above 30 ft. in HVHZ.Glass FL16177 RI AE E411ep CWS-812B(SH-8100, IMP,_ complies to ASTM E1300-04. NoSiilAnch).Ddf FL16177 R1 AE Quanex (Mikron) NOA 12-1017 02.Ddf Created by Independent Third Party: Yes Back Next " Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you,do'not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: 15 cCtecY. -.acta Credit Card it Safe URNER1239 Jabara Ave. 1 North Port,FL 34288 ENGINEERING& Ph. 941-380-1574 TCONSULTING,INC. FBPE C.O.A.#29779 Evaluation Report 812B April 18,2015 Product Description: Series 8100 PVC Single Hung,Large Missile Impact,517/8"x 613/4"unit size, +/-70 PSF,no anchors in sill Manufacturer: Custom Window Systems,Inc. 1900 SW W Ave,Ocala,FL 34474 it Statement of Compliance: This report evaluates the above-listed product per the requirements of FAC Product Approval Rule Chapter 61G20-3.005(4). This product complies with the,requirements of the 5th Edition(2014)Florida Building Code including the High Velocity Hurricane Zone. The product testing standards performed are outlined below. Technical Documentation: 1) This report,prepared by Lucas A.Turner,P.E.,at 1239 Jabara Ave.,North Port,FL 2) Approval drawing CWS-812B,signed and sealed by Lucas A.Turner,P.E. 3) Test Report NCTL-210-38154A,-2,and-2A,by National Certified Testing Laboratories,. Orlando,FL,signed and sealed by Gerard J.Ferrara,with testing performed: TAS 201/202/203- 94,ASTM E 1886-02/04/05, 1996-02/04/06/09,and AAMA/WDMA/CSA 101/I.S.2/A440-08 4) Supplemental Calculations to support CWS-812B,signed and sealed by Lucas A.Turner,P.E. Installation: Units must be installed according to approval document CANS-812B. Limitations of Use: This product: • May be used in O/X configuration in sizes and with max.glass DLO heights as shown in CWS- 812B • Is impact resistant and does not require the use of shutters • May be used in the High Velocity Hurricane Zone • Requires 7/8"Insulating Glass consisting of 1/8 Annealed or Tempered outboard lite(Tempered required above 30 ft in HVHZ) —Air—5/16 Laminated(1/8Ann-.090PVB-1/8Ann)inboard lite • Requires Dupont PVB Interlayer per Miami-Dade N.O.A. 13-0129.271, 1 • Requires Quanex(Mikron)white rigid PVC framing per Miami-Dade N.O.A. 12-1017.021 1 I have evaluated the interlayer and framing materials in these Dupont and Quanex NOAs and find that they comply with the requirements of the 5d'Ed.(2014)Florida Building'Code for use in this product. Certification of Independence: I do not have,nor do I intend to acquire,nor will I acquire,a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have,nor do I intend to acquire,nor will I acquire,a financial interest in any other entity involved in the testing or approval process of this product. °«ll6llll@fjr' Nj :• M1!0 58201 4/18/2015 Lucas A.Turner,P.E. .9'• STATE of -4u '' FL PE#58201 °R t Lucas A. Turner 2015-04-18 22:20-04:00 SINGLE HUNG - LARGE MISSILE IMPACT GENERAL NOTES:1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTUREDQ9mm TO COMPLY WITH THE FLORIDA BUILDING CODE(FBC),CURRENT EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ)AND 1900 SW 44TH AVE. IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED OCALA,FLORIDA 34474 IN ASTM E 1996 PER THE FBC. WWW.CWS.CC 2.GLAZING OPTIONS:(SEE SHEET 2) 53 1/8"MAX.OVERALL FLANGE WIDTH 8100 PVC 3.CONFIGURATIONS:"O/X". 517/8"MAX.UNIT WIDTH SINGLE HUNG 4711/16"GLASS DLO 4.DESIGN PRESSURE RATING: IMPACT -NEGATIVE DESIGN LOADS BASED ON,TESTED PRESSURE AND GLASS TABLES ASTM E-1300-04. A -POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE,WATER ,n a INFILTRATION TEST PRESSURE AND GLASS TABLES - - - - - — m co_liJ - -- -- - - ASTM E=1300-04- _— - - -- - - _ —— - — 0 1=.- __ I 5.ANCHORAGE:THE 33 1/3q STRESS INCREASE HAS NOT BEEN USED MAX. - -- - IN THE DESIGN OF THIS PRODUCT.SEE SHEET 6 FOR ANCHOR g Q OVERALL I I DETAILS. WINDLOAD DURATION FACTOR Cd-1.6 WAS USED FOR WOOD w m m FLANGE ANCHOR CALCULATIONS. U) HEIGHTO v a Z B I B 26 13116" 6.PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE LL b , Q GLOSS NOT REQUIRED. c ,� I I I 7.ALL FRAMES AND VENTS FULLY WELDED.SMALL JOINT SEAM SEALANT w w Occ Ljj 613/4" I I USED AT FIXED MEETING RAIL AND JAMB. o Dcc a HEIGHT 8.SERIES/MODEL DESIGNATION SH-8100. 9.THE DESIGNATION X AND O STAND FOR THE FOLLOWING: D ¢ o X-OPERABLE SASH,O-FIXED SASH m ¢ O 30 3/16" I I 1"7 10.SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR Z SA H HELOCATION. G oSs LOCATION. -``PNflREW�T(%�ii g 11.EXTERNAL WEEP SLOT=1/4"x 1-1/4"LOCATED 4"FROM BOTH ENDS. No 58201 :�95 6 G*� * :*_ SLIT Lucas A. % ° a I ^9� STATE OF :�: -_-_ - Turner ��,�•.,�c oP��_�.�� A 2015-04-11 '•`� °a `' A 6 15:15-04:00 451/16" GLASS DLO 48 3/8" 4/11/2015 MAX.SASH WIDTH LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: GENERAL NOTES AND ELEVATIONS TABLE OF CONTENTS DRAWN BY: DATE: .GENERAL NOTES&ELEVATIONS.....1 DESIGN PRESSURE BAT 06/18/12 GLAZING DETAIL.................................2 MAX. UNIT SIZE IMPACT RATING SECTION VIEWS.................................3 RATING EXTRUSIONS&B.O.M........................4 CWS-812 B ANCHOR SCHEDULE&NOTES.........5 51-7/8"x 61-3/4" +/- 70 PSF LARGE MISSILE IMPACT SCA INSTALLATION DETAILS....................6 SHEET 1:15 1 OF B WINDOW SYSTEMS 1900 SW 44TH AVE. 1 OCALA,FLORIDA 34474 WWW.CWS.CC 8100 PVC SINGLE HUNG IMPACT N N r LLD 000r o o � 7/8"OVERALL INSULATED GLASS 7/8"OVERALL INSULATED GLASS Y � Q W R1 m 1/8'ANNEALED OR TEMPERED 1/8"ANNEALED OR TEMPERED (j) U a Z 7/16"AIRSPACE 7/16"AIRSPACE m b 0 5/16"LAMINATED GLASS 5/16°LAMINATED GLASS 1/8'ANNEALED 1/8'ANNEALED a ? O w .090"PVB INTERLAYER BY DUPONT .080"PVB INTERLAYER BY DUPONT w LL 1/8°ANNEALED 1/8'ANNEALED p v DURASEALBYTRUSEALDURASEALBYTRUSEAL 4 PURFECT GLAZE"H"OR SIKAFLEX 552 4 PURFECT GLAZE"H"OR SIKAFLEX 552 m Q Z 14 1/2 GLASS BITE 1/2"GLASS SITE 0%%t, DREW "I 142 48 48v No 58201 '�-P 3 pro: a. 71 1 0 '9 STATE OF .'411 FIXED LITE SASH LITE 4/11/2015 LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941.380-1574 SHEET DESCRIPTION: GLAZING DETAILS DRAWN BY: DATE: BAT 06/18/12 0 : REV.: CWS-812 B SCALE: SHEET 1:1 20F6 INTERIOR WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA,FLORIDA 34474 WWW.CWS.CC 45 32 S3 12 38 13 3 32 4 45 8100 PVC ° . ° ® 1 1 ° SINGLE HUNG IMPACT 45 14 32 2 Q } - - 3 14 54 14 65 66 63 19 4 W m m SECTION B-B U) 64 C.) a Z NOTE:LEFT SIDE SHOWS FIXED SECTION VIEW, m c O RIGHT SIDE SHOWS SASH SECTION VIEW. v ,R, S2 w w g oWC o D a 14 39 w wCC y 40 0 W 2 8 ¢ D 1 32 INTERIOR m ¢ O 9 Z 4e , g�GREW 62 a `Op`'.�..G E N SF G,Qy��4 v:• No 58201 •'�-P 14 53 'P STATE OF 0441 T P 65 10 .. � .. •oei CC•�.�O R 10•O�N ss 62 .. 32 32 n 3 4/11/2015 18 6 - LUCAS A.TURNER,P.E. 2 4 FL PE#58201 3 1239 JABARA AVE. 30 NORTH PORT,FL 34288 0 PH.941-380-1574 0 SHEET DESCRIPTION: SECTION A-A SECTION VIEWS D . ' BAT 06/18/12 NOTE: ITEMS NOT SHOWN FOR CLARITY: CWS-812 B 20,25-26,36-37,44;51752,55-56,64,67-68 SCALE: SHEET 1:2 3OF6 PARTS LIST FRAME CORNER STEM PARTq IDESCRIPTION VENDOR MATERIAL 31/6"� CONSTRUCTION 1 H-6031 Main Fr.,SH,w/FI .,PVC,Head Mikron Vinyl WINDOW SYSTEMS 2 H-6031 Main Fr.,SH,w/FI .,PVC,Sill Mikron Vinyl WI 1 15/16' SW 44TH AVE. 3 H-6031 Main Fr.,SH,w/Flg.,PVC,L.Jb. Mikron Vinyl 1 I-—23/16^ 2OCALA,FLORIDA 34474 4 H-6031 Main Fr.,SH,w/Flg.,PVC,R.Jb. Mikron Vinyl 3 e WWW.CWS.CC 6 S-1577 Impact Hook Keymark Alum L FE10 8 H-6027 Sash Meet.Rail,PVC Mikron Vinyl 211/16" 4 1 5/e" rIQ 1 5/8" 9 H-1497 Reinf.Sash Meet.Rail Keymark Alum 1/16" I LI 1/1g" 8100 PVC 10 H-6028 Sash Bottom Rail,PVC Mikron Vinyl lJ 1/16" CORNER WELD SINGLE HUNG 12 H-6004 Sash Side/Top/Bot.Rail Mikron Vinyl (ALL SIDES) 13 S-1498 IReInf.S.B.R./S.S.R IMPACT 14 8-6064 Glz.Bd.,7/8" Mikron Vinyl PVC FRAME FLANGE-6031 PVC SASH BTM.RAIL-6028 PVC SASH TOP RAIL-6027 18 8.6013 Scm.Adapt.,w/Nib,PVC,Horiz. Mikron Vinyl !� a 19 S-6014 Scrn.Adapt.,PVC,Vert. Mikron I Vinylc - F 1 1/2' 20 8-6029 Sash Stop/Filler,PVC,Vert. Mikron Vinyl 1 3/16" 3 a o a 23 H-1699 Reinforcement,SBR Keymark Alum 7/8' m 1 24 P-2190 Balance BSI 9/16' 1 25 P-3059 Sash Cam,PVC BSI PlasticO ��� �,q3 w m m 26 P-3046 Take Out Clip BSI SS O 1 5/8" 2 1/8" 1/16" FIXED MEETING RAIL U)1/16° SCREWED TOGETHER WITH U N Z 27 P-3783 Lock,Impact,PVC Interlock 1/16" OUTERFRAME LL O 28 P-4069 Keeper,Impact,PVC Interlock Zamac 1:8 a N CD REINF.,IMPACT HOOK-1112 0 30 P-3215 Weep Cover w/Flap Geer Plastic a o Z W 32 P-3429 Wstp.,0.270 x.187 back FinSeal,Gray 0 cc Ultrafab PVC SASH SIDE RAIL-6004 FIXED RAIL-1836 w � 37 P-4638 #8 x 2-1/2 PH Mod.Truss,Type A,TEK 2 Fastenal Steel o a 38 P-3768 #8 x 0.825 Ph PH SMS Hub City Steel 1 5/16^ 9/16^ rw z U 39 P-4051 W#8 x 1.250 Ph FH TEK,WM. Hub City Steel 1/2^ 1 1!6' S/1s" 1 1/8" a 0 w 40 P-4264W#8 x 3/4 FH PH w/#6 Head,TEK,Wht. Hub City Steel o 7 I D ¢ o 44 P-3342 Seam Sealer,SM-5504 Schnee 7/8° 18 1 5/16" 19 45 P-3752 Cap Plug,1/2"Hole M&M Nylon 1/16. 045' 1/16° 00 < z 1/16" 47 P-3438 Set.131x 552 or Purfe8"Glaze x 2 g Si F.Lowe PVC SCREEN CATCH-6013 PVC FIXED RAIL COVER-6063 PVC SCREEN SUPPORT-6014 ,`,��y�Pt4ORE41, 48 P 3352 Set.Blk.,85 Dur.,1/8"x5/8"x 2"L . F.Lowe Rubber PVC SASH STOP-6025 51 P-3881 Temporary Lbl.(NFRC/DP) �. p; vCENg'• Q �, 52 P-3613 CWS Lbl.(logo) Pro Label 5/8" �� •"°yt� 53 Sash SEE SHEET 2 GLASS 3/4" 1/a"� f- ��: No 58201 3/4" 3/16 " 54 Fixed SEE SHEET 2 GLASS T-L= 3 �— 14 - 56 P-3281 Spacer Duraseal T 13 15/16 1/16^ 7/6° --a. 62 P 3218 Screen Frame,Horiz. Allmetal Alum 1/16^ '90;• STATE OF ;40 63 P-3218 Screen Frame,Vert. Allmetal Alum REINF. BTM RAIL-1699 REINF.TOP RAIL-1497 PVC GLAZING BEAD-6064 i tO p t 64 P-3321 Screen Frame Corner Key Allmetal Plastic REINF.S.B.R./S.s.R.-lase �4i SAO E����� 65 P-3581 Screen Cloth,18 x 16 Fiberglass Bettervue Fiberglass ►���� 66 P-3228 Screen Spline,.155 Dia.,Blk. Dapa Vinyl Iz✓� 67 P-3029 Screen Pull Tab Summit Alum 4/11/2015 68 P-3033 Screen Spring,SS Fl.Screen SS 70 P-3113 Screw Support for PVC T.Plastics Nylon LUCAS A.TURNER,P.E. 71 H-1836 Alum.Fixed Rail Keymark Alum 0 3/16„ FL PE#58201 72 S-6063C2 er,Fixed Rail Mikron Vinyl O 1239 JABARA AVE. NORTH PORT,FL 34288 73 S-1112 Reinforcement,Impact Hook Keymark Alum PH.941.380.1574 74 P-3541 1#8 x 1/2",Pan Head,TEK Fastenal Steel 15/16" 1/2" SHEET DESCRIPTION: LINE ITEMS NOT USED: s 5 3116"] 1 3" y BOM AND EXTRUSIONS 5,7,11,15-17,21-22,29,31,33-36,41-43.46,49-50, " 55,57-61,69 } � 70 7/6" 1/16" O SCREW SUPPORT-3113 DRAWN BY: DATE: IMPACT HOOK BAT 06/18/120# S-1577 D : . CWS-812 B NOTE:ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. SCALE` SHEET 1:2 40F6 IM6"MAX.(TYP.) 17"MAX.O.C.(TYP.) WINDOW SYSTEMS -" 1900 SW 44TH AVE. 6•MAX.(TYP.) OCALA,FLORIDA 34474 SEE NOTE 2 8100 PVC 101/2" I I V MAX O.C. SINGLE HUNG (TYP')-�— IMPACT O INSTALLATION ANCHOR(TYP.) - I I N . -- - -- - "-- -- --1- — - - - ---- I - - -- -- - - - maoW 1 __— MTO RAIL ~ W 0] m 4"(TYP.) I I 07 I I c 0 a £ CA m 10112" ¢ ¢ p MAX.O.C. i (TYP.) w 0: ao d I ^ I a I 4 I o Ld w LJW � O 4•(TYP.) Q Z 4"(TYP.) NO ANCHORS REQUIRED IN SILL ANCHORLAYOUT-(FLANGE) :JGP;•��CENSF., r No 58201 :9� NOTES: 9O� STATE OF :441 1.INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION.NO ANCHORS REQUIRED IN SILL, i�c0•�C R l9 P:N 2.SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX.ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16"IS PRESENT. LOAD BEARING SHIMS SHALL BE ���4►S�OfVA�++EGA, CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED. 3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 6. 4/11/2015 4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST LUCAS A.TURNER,P.E. BE PROTECTED TO PREVENT REACTION. FL PE#58201 1239 JABARA AVE. 5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM NORTH PORT,FL 34288 SPECIFIED IN TABLE 1,SHEET 6. PH.941-380-1574 6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE. SHEET DESCRIPTION: INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND THE SUBSTRATE. ANCHOR SCHEDULE AND INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. NOTES 7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:3"FOR MASONRY,1"FOR WOOD AND METAL. D B : . 8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. BAT 06/18/12 SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. CWS-812 B 9,SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: C SHEET FMAIAAMA 100(FIN WINDOWS),FMAIAAMA 200(FLANGE WINDOWS), FMA/WDMA 250(BOX WINDOWS),FMA/AAMAIWDMA 300(EXTERIOR DOORS) 1:15 5OF6' TYPICAL HEAD ANCHORAGE MIN.EMBEDMENT WINDOW SYSTEMS L MIN.EDGE DIST. BY SEE TABLE 1 SUBSTRATE SEE TABLE 1 1/4"MAX.SHIM SEE TABLRE 1 OCALA,S 1900 SW LTH AVE. t CAFLORIDA 34474 SUBSTRATE BY OTHERSW W W.CWS.CC SEE TABLE 1 MIN.EMBEDMENT PERIMETER SEALANT SEE TABLE 1 MIN.EDGE DIST. 8100 PVC BY INSTALLER SEE TABLE 1 INSIDE AND OUT INSTALLATIONSINGLE HUNG' SEALANT BEHIND C� SEE TABLEANCHOR IMPACT FLANGE BY INSTALLER 1/4"MAX.SHIM �2 N .- W Om co Q O � � PERIMETER SEALANT y BYINSTALLER Q } INSTALLATION ANCHOR INSIDE AND OUT w m m SEE TABLE 1 SEALANT BEHIND � FLANGE BY INSTALLER LL a 0 HORIZONTAL SECTION c N LD CONTINUOUS DOUBLE 3/16"BEADS OF a Z > TREMGLAZE U1600 SEALANT AROUND 6 TYPICAL JAMB ANCHORAGE w Q O LU PERIMETER AT ALL INDICATED POINTS a BETWEEN FRAME AND BUCK BY INSTALLER. w ccLL U 1/4"MAX.SHIM p 0 U SEALANT BEHIND am ¢ D FLANGE BY INSTALLER m Q Z EMBEINSIDE AND OUTIMETER SEALANT S E TABLEDMENT ,,y�P�D `�JVP�•v� SF•;'py�� t No 58201 -p SUBSTRATE BY OTHERS SEE TABLE 1 MIN.EDGE DIST. SEE TABLE I �9� STATE OF -4(1 O O ox�K / �A1 VERTICAL SECTION + '.• !V 6 TYPICAL SILL ANCHORAGE .....R1 .✓'G�=��` 4/11/2015 TABLE 1:APPROVED INSTALLATION FASTENERS LUCAS A.TURNER,P.E. SUBSTRATE TYPE ANCHOR TYPE MIN.EMBEDMENT MIN.EDGE DIST. FL PE#58201 CONCRETE 2.0 KSI MIN. 3/16"ITW TAPCON 1-1/2" 1-1/8" PERIMETER SEALANT 1239 JABARA AVE. ( ) BY INSTALLER NORTH PORT,FL 34288 HOLLOW OR GROUT-FILLED CMU(117 PCF INSIDE AND OUT MIN.) 3/16"ITW TAPCON 1" 2" \� HORIZONTAL SECTION PH.941-380-1574 C \ CONCRETE(2.85 KSI MIN.) 3/16"ELCO ULTRACON 1" 1" 6 BOX FRAME INSTALLATION SHEET DESCRIPTION: GROUT-FILLED CMU(ASTM C-90) 3/16"ELCO ULTRACON 1-1/4" 2-1/2" HEAD AND SILL SIMILAR FOR BOX INSTALLATION 3/16"ITW TAPCON INSTALLATION DETAILS 2X MIN.SOUTHERN PINE(G=0.55) 1-3/8" 7/8" OR ELCO ULTRACON FLANGE REMOVAL NOTE:PARTIALLY OR FULLY REMOVING THE FLANGE, 2X MIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-3/8" 7/8" UP TO AND INCLUDING A BOX-FRAME APPLICATION IS ACCEPTABLE PROVIDED: DRAWN BY: DATE: 16 GAUGE(0.060")MIN.STEEL STUD #10-16 HILT KW IK-FLEXOR ITW FULL THREAD BAT 06/18/12 (33 KSI YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.060" 7/16" MIN.1/4"FILLET OF CONSTRUCTION-GRADE ADHESIVE CAULK IS APPLIED ­CWG#: R .: 1/8"ALUM.(6063-T5 MIN.)OR #10 GRADE SSELF-TAPPING/ FULL THREAD INSIDE AND OUT,FULL PERIMETER,BY INSTALLER. CWS-812 BPRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS 1/8"STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125" 7/16 SHOWN FOR FLANGE WINDOWS. SCALE' SHEET 1:2 6OF6