HomeMy WebLinkAboutSoprema Resisto Lastobond- UnderlaymentFlorida Building Code Online
http://www.floridabuildirig,org/pr/pr_app dtf.aspx?parani—�r(EVX,..
Submit Surcharge Stats & Facts Publications FBC Staff 6CIS Site Ma
> Az,) n beard. >A• EcatE�a!,ist> Application Detail
FL 11
FL2569-Rll
Application Type
Revision
Code Version
2014
Application Status
Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Soprema, Inc. (Canada)
1640 rue Haggarty
Drummondville, NON -US 00000
(819)478-2400 Ext 3327
memath ieu @soprema.ca
Marc -Etienne Mathieu
memath ieu@soprema.ca
Marc -Etienne Mathieu
1688 lean -Berch ma ns -M ichaud
Drummondville, NON -US 00000
(819) 478-2400 Ext 3327
memath ieu@soprema. ca
lean -Francois Cote, Ph.D.
1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect o
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Robert J. M. Nieminen
PE -59166
UL LLC
10/16/2017
John W. Knezevich, PE
of 3 I/5/2016 3:08 PM
7lorida Building Code Online
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
mars of Products
http://www.flori dabuilding- org/pr/pi_app_dti. aspx?param—wGEV X...
Validation Checklist - Hardcopy Received
F ? ? c �—R }. l -_CID, 2.'_z :_� 0.1; C 01
_
Standard
ASTM D1970
ASTM D6163
ASTM D6164
FM 4474
FRSA/TRI April 2012 (04-12)
TAS 103
TAS 110
Method 1 Option D
10/15/2015
1.0/19/2015
10/21/2015
12/15/2015
FL # Model, Number or Description
Name I
r2569.1 Soprema Roof Self adhering roof underlayments
Underlayments
Limits of Use
Approved for use in HVHZ: No
Approved for use outsideP.,_1df
Installation Instructions
� F 2569 R11 II 2015 10 FINALSORSORREMA CA 1 NJgEER €1 -Lf
HVHZ: Yes I
Verified By: Robert Nieminen, P.E. PE -59166
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -90
Evaluation Reports
Other: 1.) Refer to ER Section 5 for
FL2569 R11 AE 20,5 1C FINAi- ER SOPREM.A CA UNDERLAY
R1�1.d.`
Limits of Use. 2.) The design pressure
noted herein pertains to underlayment
Created by Independent Third Party: Yes
systems used. beneath adhesive -set the
systems. Refer to ER Section 5.6.4 for
details.
Back Next
Cont3.Ci._i)s :: 14497 North Monroe Street, Taliah0=e_FL 32399 Phone: 850-487=1824
The State of Florida is an AA/EEO employer. Coovriaht 2007-2013 State of Florida.:: Privacy Statement Arcm5jW' _ StatemenF :: gi
Under Florida law, email addresses are public records, If you do not want your e-mail address released in response to a public -records req
of 3 1/5/2016 3:08 PM
Florida Building Code Online http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVX...
electronic mail to this entity. instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department wi
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. it
supply a personal address; please provide the Department with an email address which can be made available to the public. To determine ff yo
Chapter 455, F.S., please click herd.
Product Approval Accepts:
M e hEsR
SCc'l6Tl'tV".i. i
of 3 1/5/207.6 3:08 PM
TERD
EVALUATION REPORT
Sop.rerna, Inc.
1640 rue Haggerty
Drummondville, Quebec J2C 5P8
Canada
SCOPE:
EXTERIOR RESEARCH & DESIGN, LLC,
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE.: (203) 262-9245
FAX. -(203)2G2-9243
Evaluation Report S18010.06.09 -R9
FL2569-R11
Date of Issuance: 06/15/2009
Revision 9:10/12/2015
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: 5oprervla Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinityl ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 591 S6, Florida DCA ANE1983
The faesrrnHe.sea Iappear Ing was authorized by Robert Nieminen,
P.E. on 10/1212015, This does not serve as an electronically signed
document, signed, sealed hardcopies have been transmitted to the
Product Approval AdmEnistrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityi ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This Is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
Txb
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
following sections of the Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Resistance
FM 4474
2004
1507.2.4, 1507.2.8,
Physical Properties
ASTM D1970
2009
1507.2.9.2, 1507.4.5.1,
ASTM D1970 / TAS 110
2974.03.05-2
05/17/2005
1507.5.3, 1507.7.3
Wind Resistance
2778.07.05
07/15/2005
1507.11.2
Physical Properties
ASTM D6163
2000
1507.11.2
Physical Properties
ASTM D6164
2005
1523,6.5.2.1
Physical Properties
TAS 103
1995.
TAS'110
Accelerated Weathering
TAS 110
2000
1507.3.3
Installation Practice
FRSA/TRI April 2012 (04-12)
2012
3. REFERENCES:
gniity
Examination
Reference
Date
ERD (TST6049)
ASTM 01970 / TAS 110
2968.05.04-2
05/14/2004
ERD (TST6049)
Physical Properties
2757.02.05
02/03/2005
ERD (TST6049)
ASTM D1970 / TAS 110
2974.03.05-2
05/17/2005
ERD (TST6049)
Wind Resistance
2778.07.05
07/15/2005
ERD (TST6049)
Wind Resistance
2779.11.05-R1
04/18/2007
ERD (TST6049)
TAS 103 / TAS 110
57120.1.1.07-2
11/02/2007
ERD (TST6049)
ASTM D1970 / TAS 110
S13190.02.09 -R1
04/01/2010
ERD (TST6049)
ASTM D1970 / TAS 110
531370.03.10-1-R1
04/07/2010
ERD (TST6049)
Physical Properties /Tensile Adhesion
S11150.05.10 -R1
09/09/2010
ERD (TST6049)
Physical Properties /Tensile Adhesion
511150.05.09-R2
10/05/2010
ERD (TST6049)
ASTM D1970
537210.11.11
11/09/2011
ERD (TST6049)
ASTM D1970
S40540.02.13-1
02/19/2013
ERD (TST6049)
Physical Properties/ Tensile Adhesion
S43530.02.14-1
02/21/2014
ERD (TST6049)
Physical Properties / Tensile Adhesion
SOPC-SC7645.02.15
02/13/2015
ERD (TST6049)
Accelerated Weathering
SOPC-SC8S20.14
04/17/2015
M -D (CER1592)
HVHZ Compliance
09-1005.02
11/04/2010
M -D (CER1592)
HVHZ Compliance
13-0530.02
11/27/2014
ICC -ES (EVL2396)
2012, 2009 and 2006 IBC Compliance
ESR -1524
10/03.12014
PRI (TST5878)
Physical Properties
SOP -064-02-01
12/03/2013
Soprema, Inc. (PDM3511)
Equivalency Declaration
SA SMOOTH PLY 40
05/29/2015
UL, LLC (QUA9625)
Quality Control
Service Confirmation
Exp. 10/16/2017
4. PRODUCT DESCRIPTION:
4.1. Lastobond TU HT is a self -adhering, non -woven polyester fabric surfaced, SBS modified bitumen roof
underlayment.
4.2 Lastobond Shield is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment available in two widths; 36 and 45 inch.
4.3 RESISTO SA SMOOTH PLY 40 is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment; available in 3.3 ft x 65 ft rolls.
Exterior Research and Design, LLC. Evaluation Report 518010.06.09-R9
Certificate ofAuthoriration #9503 FL2569-R22
Revision 9: 20/12/2015
Page 2 of 7
5:
TNT"'Y-
4.4 Lastobond Shield HT is a self -adhering, woven polyethylene surfaced, high temperature, SBS modified
bitumen roof underlayment.
4.5 Lastobond Pro HT -N is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment available in two widths; 36 and 45 inch.
4.6 Lastobond Pro HT -5 is a self -adhering, woven polyethylene surfaced, high temperature, SBS modified
bitumen roof underlayment.
4.7 Lastobond 195 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof
underlayment.
4.8 Lastobond is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof
underlayment.
4.9 Lastobond Eco is a self -adhering, glass -mat reinforced, sand -surfaced, SSS modified bitumen roof
underlayment.
4.10 Lastobond Smooth Seal HT is a self -adhering, glass -mat reinforced, film -surfaced, SBS modified bitumen
roof underlayment.
4.11 RESISTO LB1236 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof
underlayment, with a 36 -inch sheet width.
4.12 PrimeSource Grip -Rite Eave & Valley Protector is a self -adhering, glass -mat reinforced, sand -surfaced, SBS
modified bitumen roof underlayment, with a 36 -inch sheet width.
4.13 RESISTO LB1244 is a self -adhering, glass -mat reinforced, sand -surfaced, 585 modified bitumen roof
underlayment, with a 44 -inch sheet width.
4.14 Colphene FR GR is a self -adhering, fiberglass reinforced, granule -surfaced, SBS modified bitumen roof
underlayment.
4,15 Unilay (e) is a mechanically attached, polyester reinforced, granule -surfaced, SBS modified bitumen roof
underlayment.
LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.L. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval
based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop the underlayments are follows:
TA 13LE 1: ROOF COVER OPTIONS
Underlayment
Asphalt
Nail -On
Imam -on
Metal
wood Shakes &
Slate
Shingles
Tile
Tile
Shingles
Yes
Lastobond TU HT
Yes
Yes
Yes
Yes
Yes
See 5.5:1
Lastobond Shield / Pro HT -N /
Yes
No
No
No
Yes
Yes
RESISTO SA SMOOTH PLY 40
Lastobond Shield HT / Pro HT -S
Yes
No
No
Yes
Yes
Yes
Lastobond / Lastobond 195 1
Yes
No
No
No
Yes
Yes
Exterior Research and Design, LLC. Evaluation Report S18010.06.09-119
Certificate of Authorization #9503 FL2569-R11
Revision 9: 10/12/2015
Page 3 of'7
T�.ER
TABLE 1: ROOF COVER OPTIONS
Underlayment
Asphalt
Mail -On
Foam -On
Metal
Wood Shakes &
Slate
Shingles
Tile
Tile
Shingles
Lastobond ECO / RESISTO
LB1236, Grip -Rite Eave & Valley
Yes.
No
No
No
Yes
Yes
Protector/ RESISTO LB1244
Lastobond Smooth Sea] HT
Yes
No
No
Yes
Yes
Yes
I Colphene FR GR
Yes
Yes
Yes
No
Yes
Yes
See 5.5.1
Unilay (e)
Yes
Yes
Yes
No
No
No
Batten Only
See 5.5.1
5.5.1 "Foam -On Tile" is limited to .use of the following adhesives unless tensile adhesion / long term aging data
from an accredited testing laboratory is provided.
Llnderlayment
Adhesive(s)
Lastobond TU HT
3M 2 -Component Foam Roof Tile Adhesive AH -160 (FL6332) or Dow Chemical TUeBondT" Roof
Tile Adhesive (FL717)
Colphene FR GR
3M 2 -Component Foam Roof Tile Adhesive AH -160 (FL6332)
Unilay (e)
3M 2 -Component Foam Raaf Tile Adhesive AH -160 (FL6332)
5.6 Allowable substrates are noted below:
5.6.1 Direct -Bond to Deck: .
Lastobond Shield, Lastobond Pro HT -N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT -S, Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, RE51STO 1_131236, Grip -Rite Eave &
Valley Protector, RESISTO LB1244 or Lastobond Smooth Seal HT applied to:
r Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41
primed Southern Yellow Pine; ASTM D41 primed structural concrete.
Colphene FR GR applied to:
s Plywood; ASTM D41 primed plywood; ASTM D41 primed structural concrete.
N ote:
➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends
priming with Elastocol Stick or Elastocol 6000 if the final roof cover is not slated for installation within
24 hours.
Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to
installation of the self -adhering underlayment.
5.6.2 Bond -to -Insulation:
Lastobond Shield, Lastobond Pro HT -N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT -S, Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, RESISTO L131236, Grip -Rite Eave &
Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to.:
Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam -on tile systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified
design professional and installed based on testing of the insulation/underlayment system in accordance
with FM 4474, Appendix D or TAS 114, Appendix J.
Exterior Research and Design, LLC. Evaluation Report 518010.06.09-R9
Certificate ofAuthorizatiolt #9503 FL2569-R11
Revision 9:10/12/2015
Page 4 of 7
TRINIT, Y: EK
5.6.3 Bond to Mechanically Attached Base Laver'
Lastobond Shield, Lastobond Pro HT -N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT -S, Lastobond TU HT, Lastobond, Lastobond 195, Lastobond FCO, RESISTO LB1236, Grip -Rite Eave &
Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to:
ASTM 0226, Type I or II felt; 5opra-G; Modified Sopra-G.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam -on the systems (Lastobond TU HT only),
base layer shall be attached in accordance with FRSA/TRI April 2012 (04-12)..
5.6.4 Wind Resistance for Underla meat Systems in Foam -On Tile Applications- FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where
the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment
systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications.
Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per I=BC 1504.9 has
already been applied). Refer to FBC 1609 for determination of design wind pressures.
5.6.4.1 Maximum Desian Pressure= -4.5.0 psf.
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional) Elastocol Stick or Elastocol 6000
Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered.
5.6.4.2 Maximum Design Pressure = -67.5 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: Elastocol 600c
Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered.
5.6.4.3 Maximum Design Pressure _= -60.0 psf
Deck: Min. 19/32 -inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FSC 1517.5.1) and tin
caps (FBC 1517.5.2) spaced 6 -inch o.c. at the 4 -inch laps and 6 -inch o.c. in three, equally
spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered
5.6.4.4 Maximum Design Pressure = -90.0 psf.
Deck: Min. 19/32 -inch plywood to meet project requirements to satisfaction of AHJ.
Underlayment: Unilay(e) mechanically attached with Soprafix Polymer Batten Bar (PBB) or Soprafix
Metal Batten Bar (MBB) with Soprema #15 -EL fasteners spaced 6 -inch o.c. within the 5 -
inch wide, self -adhering side laps. End laps are 6 -inch wide and sealed using either
heat -welding or hot-air welding techniques.
5.7 Exposure Limitations:.
Lastobond, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236, Grip -Rite Eave &
Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30 -days after installation.
Lastobond Shield, Lastobond Pro HT -N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond
Pro HT -S shall not be left exposed for longer than 90 -days after installation.
Lastobond TU HT or Colphene FR GR or Unilay(e) shall not be left exposed for longer than 180 -days after
installation.
Exterior Research and Design, LLC. Evaluation Report 518010:06.09-119
Certificate of Authorization #9503 FL2569-RIl
Revision 9:1011212015
Page 5 of 7
Y ER
6. INSTALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick or
Elastocol 600c (if applicable).
6.3 Lastobond TU FIT, Lastobond Shield, Lastobond Pro HT -N, RESISTO SA SMOOTH PLY 40, Lastobond Shield
HT Lastobond Pro HT -S, Lastobond Lastobond 195 Lastobond Eco Lastobond Smooth Seal HT RESISTO
LB1236 Grip -Rite Eave & Valley Protector RESISTO L81244 or Col bene FR GR:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 Non -Tile Applications:
While priming is optional, Soprema recommends priming with Eiastocol Stick or Elastocol 600c if the final
roof cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel -off the release film diagonally while holding the
membrane tight. Firmly roll the membrane into place to achieve a bond.
Horizontal seams should be minimum 3 -inches, configured to shed water. Vertical seams should be 6 -
inches and staggered not less than 2 -ft from vertical seams in the course below. All over -granule end -laps
shall be sealed using either heat -welding. or hot air welding techniques.
When installing at slopes above 8:12, Soprema recommends back -nailing in the overlap area at the top of
the sheet at 12 -inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys, apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications Lastobond TU HT or Col hese FR GR only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
For foam -on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012 (04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
6.4 Unlla e :
6.4.1 Non -Tile Applications or hail -On, Battened Tile Applications:
Reference is made to Table 1 herein and FRSA/TRI April 2012 (04-12) Installation Manual (if applicable).
Apply sheet parallel to the roof edge and, starting at the eave with the selvedge -edge upslope,
mechanically attach the 5 -inch wide selvedge -edge to the wood deck with nails and tin caps or round cap -
nails spaced 36 -inch o..c. Apply the second course in a water -shedding manner with self -adhering side -
laps. Vigorous hand or motorized roller pressure is applied to the self -adhering laps to ensure a watertight
application.
Vertical seams should be 6 -inches and staggered not less than 2 -ft from vertical seams in the course
below. All over -granule end -laps shall be sealed using either heat -welding or hot air welding techniques.
Exterior Research and Design, LLC. Evaluation Report S1010.06.09-119
Certificate ofAuthorizatiart 119503 FL2569-R11
Revision 9: 10/12/2015
Page 6 of 7
5 toTRNmow.
Tile (if applicable) shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underiayment.
6.4.E Foam -On Tile Applications:
Reference is made to FRSA/TRl April 2012 (04-12) Installation Manual, Table 1 herein and Section 5.6.4.4
herein.
Apply sheet parallel to the roof edge and, starting at the eave with the selvedge -edge upslope,
mechanically attach the 5 -inch wide selvedge -edge to the wood deck Soprafix Polymer Batten Bar (PBB) or
Soprafix Metal Batten Bar (MBB) with Soprema #15 -EL fasteners spaced 6 -inch o.c. Apply the second
course in a water -shedding manner with self -adhering side -laps. Vigorous hand or motorized roller
pressure is applied to the self -adhering laps to ensure a watertight application.
Vertical seams should be 6 -inches and staggered not less than 2 -ft from vertical seams in the course
below. All over -granule end -laps shall be sealed using either -heat -welding or hot air welding techniques.
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for information on plants covered under Rule 61G20-3 QA
requirements.
9, QUALITY ASSURANCE ENTITY:
UL, LLC —QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- ENO OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation. Report 51$010.06.09-119
Certificate of Authorization.#9503 FL2569-R11
Revision 9:10/12/2015
Page 7 of 7