Loading...
HomeMy WebLinkAboutProduct Approval (3) Florida Building Code Online Page 1 of 3 7 W.„�; "+m �-�"-'4"'"` AV, 0'4 BCIS Home 1 Log In i User Registration ± Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff SCIS Site Maprc4 ^Links ; Search 02i-i Product Approval USER;Public User ` ;'roArsct ApprovalMenu>Product or Application Searrh>Aonlication List>Application Detail jum 02 noii, PEh Jt l'. -,IG FL# FL242-R21 _!.'C1E C:O L.!ltt.' !={ Application Type Revision -' Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. s ^� Comments i:; 5 Archived t�+aTSr"��+,Y Product Manufacturer PGT Industries +a. + Address/Phone/Email 1070 Technology Drive North Venice,FL 34275 (941)486-0100 Ext 22318 druark@pgtindustries.com Authorized Signature Jens Rosowski jrosowski@pgtindustries.com Technical Representative Jens Rosowski Address/Phone/Email 1070 Technology Drive Nokomis,FL 34275 (941)486-0100 Ext 21140 jrosowski@pgtindustries.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Horizontal Slider Compliance Method Certification Mark or Listing r, Certification Agency Miami-Dade BCCO-CER Validated By Miami-Dade BCCO-VAL Referenced Standard and Year(of Standard) Standard Year TAS 201,202,203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 09/07/2016 Date Validated 10/17/2016 Date Pending FBC Approval Date Approved 10/17/2016 http://www.floridabuilding.org/pr/P _app_dtl.aspx?param=wGEVXQwtDquUsDrhuM3D... 5/23/2017 Florida Building Code Online Page 2 of 3 Summary of Products FL# Model,Number or Name Description 242.1 HR-210(Non-Impact) Aluminum Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL242�R71 C CAC iG-0679,_0?_pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 04/05/2022 Design Pressure:N/A Installation Instructions Other:Please see the Miami-Dade County Notice of Acceptance(NOA) FL242 R21 II 16-0629.02.odf for product performance information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER type,size,and spacing Information. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 242.2 JHR-510(Impact) WinGuard Vinyl Horizontal Roller Window I Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL242 U..c,cac 15-061,7. i4.o(jf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 02/17/2021 Design Pressure:N/A Installation Instructions Other:Please see the Miami-Dade County Notice of Acceptance(NOA) FL242 FZ21 11 15-0612.14.Ddf for product performance information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER type,size,and spacing information. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: + 242.3 HR-610(Non-Impact) WinGuard Aluminum Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL242 R21 C CAC 16-0714.14.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 07/27/2021 Design Pressure:N/A Installation Instructions Other:Please see the Miami-Dade County Notice of Acceptance(NOA) FL242 R21 I1 16-0714.14.01 for product performance Information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER type,size,and spacing Information. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 242.4 JHR-710(Impact). WinGuard Aluminum Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL242 221 C CAC 16-071 4.13.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/21/2021 Design Pressure:N/A Installation Instructions Other:Please see the Miami-Dade County Notice of Acceptance(NOA) FL242 R21 II 16-0714.13.odf for product performance information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER type,size,and spacing information. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 242.5 JHR-810(Large Missile Impact) Multi-Story Aluminum Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL242 R21 C CAC 16-0714.10.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 11/01/2017 Design Pressure:N/A Installation Instructions Other:Please see the Miami-Dade County Notice of Acceptance(NOA) FL242 R21 II 16-0714.10.0 for product performance information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER type,size,and spacing Information. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 242.6 HR-810(Small Missile Impact) Multi-Story Aluminum Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use In HVHZ:Yes FL242 R21 C CAC 16-0714.15.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 11/01/2017 Design Pressure:N/A Installation Instructions Other:Please see the Miami-Dade County Notice of Acceptance(NOA) FL242 R21 Il 16-0714.15.odf for product performance Information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER type,size,and spacing information. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 242.7 HR-2710M(Impact) 2LT HR-2710M PVC Horizontal Rolling Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL242 R21 C CAC 15-0528.23 Ntodf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/23/2020 Design Pressure:N/A Installation Instructions Other:Please see the Miami-Dade County Notice of Acceptance(NOA) FL242 R21 1. 15-0528.23 M.odf for product performance information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER type,size,and spacing Information.(2-lite XX only) Created by Independent Third Party: Evaluation Reports Created by Independent Thlyd Party: 242.8 HR-2710MI(Impact) 2/3 LT HR2710MI PVC HORIZONTAL ROLLER LMI Limits of Use Certification Agency Certificate Approved for use In HVHZ:Yes FL242 R21 C CAC 13-1125.03 Ml.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/23/2020 Design Pressure:N/A Installation Instructions Other:Please see the Miami-Dade County Notice of Acceptance(NOA) FL242 R21 It 13-1125.03 MI.ndf for product performance information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER type,size,and spacing information.(2-lite XX&3-lite XOX) Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 242.9 HR-5410(Non-Impact) Vinyl Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL242 R21 C CAC 16-0714.18.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 09/24/2020 http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquUsDrhuM3 D... 5/23/2017 Florida Building Code Online Page 3 of 3 Design Pressure:N/A Installation Instructions Other:Please see the Miami-Dade County Notice of Acceptance(NOA) FL242 R21 IT 16-0714.18.nd for product performance information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER type,size,and spacing information. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 242.10 HR-5510(Impact) Vinyl Horizontal Roller Window - Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL242 R21 C CAC 16-0714.17.0f Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 09/24/2020 Design Pressure:N/A Installation Instructions Other:Please see the Miami-Dade County Notice of Acceptance(NOA) FL242 R21 IT IC--0714.17.ndf for product performance information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER type,size,and spacing Information. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 242.11 SGD-770 Window(Impact) Aluminum Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use In HVHZ:Yes ft.242R?1 C CAC 16-0629_Q9,gdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 02/12/2020 Design Pressure:N/A Installation Instructions Other:Please see the Miami-Dade County Notice of Acceptance(NOA) L_74�._R71. Ii I6-_9&j.g0f for product performance information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER type,size,and spacing information. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 242.12 SGD-2500 Window(Non-Impact) Aluminum Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use In HVHZ:Yes FL242 R21 C CAC 15-0609 09 1NDW.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 05/22/2018 Design,Pressure:N/A Installation Instructions Other:Please see the Miami-Dade County Notice of Acceptance(NOA) FL242 R21 IT 15-0609.09 WD'dy.odf for product performance information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER type,size,and spacing information. Created by Independent Third Party: Evaluation Reports i Created by Independent Third Party: 242.13 SGD-5570 Window(Impact) Vinyl Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use In HVHZ:Yes FL242 R21 C CAC 16-0505.01.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 08/04/2021 Design Pressure:N/A Installation Instructions I Other:Please see the Miami-Dade County Notice of Acceptance(NOA) FL242 R21 IT 16-0505.0I.odf for product performance information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER type,size,and spacing information. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: ER EM Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida ::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Credit,Card safe http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquUsDrhuM3 D... 5/23/2017 MIAMI•DADE MIAMI-DADE COUNTY e PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE OA www.miamidadegov/economy PGT Industries,Inc. 1070 Technology Drive North Venice,FL 34275 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami—Dade County Product Control Section (In Miami—Dade County)and/or the AHJ(in areas other than Miami—Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone.- DESCRIPTION: Series"HIM-710"Aluminum Horizontal Rolling Window-L.M.I. APPROVAL DOCUMENT: Drawing No. 4127-10, titled "Alum. Horizontal Roller Window, Impact", sheets 1 through 11 of 11, dated 02/28/06,with revision G dated 05/05/16,prepared by manufacturer, signed and sealed by Anthony Lynn Miller,P.E., bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words .Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA915-0519.09 and consists of this page 1 and evidence pages E-1,E-2 and E-3,as well as approval document mentioned above. pp The submitted documentation was reviewed by Manuel Perez,P.E. NOA No.16-0714.13 MfAMFDADE COUNTY Expiration Date: December 21,2021 Approval Date: September 01,2016 Page 1 PGT Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA's No.-07-0815.09 and 06-0405.06) 2. Drawing No.4127-10,titled"Alum. Horizontal Roller Window,Impact", sheets 1 through 11 of 11, dated 02/28/06,with revision G dated 05/05/16,prepared by manufacturer, signed and sealed by Anthony Lynn Miller,P.E. B. TESTS 1. Test reports on: 1)Uniform Static Air Pressure Test,Loading per FBC, TAS 202-94 2)Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings and installation diagram of a PVC sliding glass door, a PVC fixed window and an aluminum sliding glass door, using: Kodispace 4SG TPS spacer system,Duraseal°spacer system, Super Spacer®NXTTM spacer system and XL EdgeTM spacer system at insulated glass,prepared by Fenestration Testing Laboratory, Inc., Test Reports No. FTL-8717, FTL-8968 and FTL-8970, dated 11/16/15, 06/07/16 and 06/02/16 respectively, all signed and sealed by Idalmis Ortega,P.E. 2. Test reports on: 1) Large Missile Impact Test per FBC,TAS 201-94 2)Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of an XOX aluminum horizontal sliding window,prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-5330, dated 07/18/07, signed and sealed by Carlos S.R.ionda,P.E. (Submitted under NOA No. 07-0815.09) 3. Test reports on: 1)Air Infiltration Test,per FBC, TAS 202-94 2)Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test,per FBC,TAS 202-94 ..4)Large Missile Impact Test per FBC,TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS.203-94 6)Forced Entry Test,per FBC 2411.3.2.1,TAS 202-94 along with marked-up drawings and installation diagram of an XOX aluminum horizontal sliding window,prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-4858, dated 03/08/06, signed and sealed by Edmundo Largaespada, P.E. (Submitted under NOA No.06-0405.06) Manuel Per E. Product Control E a ner NOA No. 16-0714.13 Expiration Date: December 21,2021 Approval Date: September 01,2016 E-1 PGT Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS (coNTTNuED) 4. Test reports on: 1)Air Infiltration Test,per FBC, TAS 202-94 2)Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3)Water Resistance Test,per FBC,TAS 202-94 ..4)Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC,TAS 203-94 6)Forced Entry Test,per FBC 2411.3.2.1, TAS 202-94 along with marked-up drawings and installation diagram of an XOX aluminum horizontal sliding window,prepared by Fenestration Testing Laboratory, Inc.,Test Report No.FTL-4859, dated 03/08/06, signed and sealed by Edmundo Largaespada, P.E. (Submitted under NOA No. 06-0445.06) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC-5th Edition (2014), dated 05/14/15,prepared by manufacturer, signed and sealed by Anthony Lynn Miller,P.E. (Submitted under previous NOA No. 15-0519.09) 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0423.17 issued to Eastman Chemical Company (MA) for their"Saflex Clear and Color Glass Interlayers"dated 06/19/14, expiring on 05/21/16. 2. Notice of Acceptance No. 14-0916.10 issued to Kuraray America,Inc. for their "Kuraray Butacite®PVB Glass Interlayer"dated 04/25/15,expiring on 12/11/16. Manuel Pe0i. Product Control ENOA No. 16 Expiration Date: December 21,2021 Approval Date: September 01,2016 E-2 PGT Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of conformance, complying with FSC-5th Edition (2014), dated May 16,2015,issued by manufacturer, signed and sealed by A.Lynn Miller, P.E. (Submitted under previous NOA No. 15-0519.09) 2. Statement letter of no financial interest, dated May 16, 2015, issued by manufacturer, signed and sealed by A. Lynn Miller,P.E. (Submitted under previous NOA No. 15-0519.09) 3. Laboratory compliance letter for Test Report No. FTL-5330, issued by Fenestration Testing Laboratory, Inc., dated 07/18/07, signed and sealed by Carlos S.Rionda,P.E. (Submitted under NOA No. 07-0815.09) 4. Laboratory compliance letter for Test Reports No. FTL-4858 and FTL-4859, issued by Fenestration Testing Laboratory, Inc., dated 03/08/06, signed and sealed by Edmundo Largaespada, P.E. (Submitted under NDA No. 06-0405.06) 5. Proposal No. 16-0125 issued by the Product Control Section, dated March 09,2016, signed by Ishaq Chanda, P.E. G. OTHERS 1. Notice of Acceptance No. 15-0519.09,issued to PGT Industries for their Series "HR-710"Aluminum Horizontal Rolling Window- L.M.I., approved on 07/09/15 and expiring on 12/21/21. Manuel Perez Product Control Exa i r NOA No. 16-0714.13 Expiration Date: December 21,2021 Approval Date: September 01,2016 E-3 GENERAL NOTES:IMPACT HORIZONTAL ROLLER FLANGED AND INTEGRAL FIN WINDOW STANDARDS USED: •2014 FLORIDA BUILDING CODE(FBC),STH EDITION 1.GLAZING OPTIONS:(SEE DETAILS ON SHEET 2).FOR INSTALLATION ABOVE 30 FT,GLASS TYPES G THRU L MUST HAVE A TEMPERED GLASS CAP. •ASTM E1300-09 •ANSIIAF&PA NDS-2012 FOR WOOD CONSTRUCTION A.5116"LAMI CONSISTING OF(2)LITES OF 1/8"ANNEALED GLASS WITH A.090-"PVB"INTERLAYER. •ALUMINUM DESIGN MANUAL,ADM-2010 •AISI-S100-07/S2-2010 B.5116"LAMI CONSISTING OF(1)LITE OF 1/8"ANNEALED GLASS AND(1)LITE OF 118"HEAT STRENGTHENED GLASS WITH A.090-"PVB"INTERLAYER. C.5/16"LAM[CONSISTING OF(2)LITES OF 118"HEAT STRENGTHENED GLASS WITH A.090-"PVB"INTERLAYER. D.7/16"LAMI CONSISTING OF(2)LITES OF 3/16"ANNEALED GLASS WITH A.090'"PVB"INTERLAYER: E.7/16"LAMI CONSISTING OF(1)LITE OF 3/16"ANNEALED GLASS AND(1)LITE OF 3116"HEAT STRENGTHENED GLASS WITH A.090'"PVB"INTERLAYER. NOA DRAWING MAP F.7/16"LAMI CONSISTING OF(2)LITES OF 3/16"HEAT STRENGTHENED GLASS WITH A.090-"PVB"INTERLAYER. SHEET G.13/16"LAMI IG:(1)LITE OF 118"OR 3116"ANNEALED(MIN.)GLASS,5/16"OR 3/8"AIR SPACE AND 5/16"LAMI GENERAL NOTES.............1 CONSISTING OF(2)LITES OF 1/8"ANNEALED GLASS WITH A.090'"PVB"INTERLAYER. GLAZING DETAILS............2 DESIGN PRESSURES.......3 H.13/16"LAMI IG:(1)LITE OF 1/6"OR 3/16"ANNEALED(MIN.)GLASS,5/16"OR 3/8"AIR SPACE AND 5/16"LAMI CONSISTING OF(1)LITE OF 1/8"ANNEALED GLASS AND(1)LITE ELEVATIONS.....................4 OF 118"HEAT STRENGTHENED GLASS WITH A.090""PVB"INTERLAYER. VERT.SECTIONS.............5 HORIZ.SECTIONS............5 I.13116"LAMI IG:(1)LITE OF 1/8"OR 3/16"ANNEALED(MIN.)GLASS,5/16"OR 3/8"AIR SPACE AND 5/16"LAMI PARTS LIST.......................6 CONSISTING OF(2)LITES OF 1/8"HEAT STRENGTHENED GLASS WITH A.090'"PVB"INTERLAYER. EXTRUSIONS....................7 CORNER DETAIL..............5 J.13/16"LAMI IG:(1)LITE OF 1/8"OR 3/16"ANNEALED(MIN.)GLASS,3/16"OR 1/4"AIR SPACE AND 7116"LAMI ANCHORAGE....................8-11 CONSISTING OF(2)LITES OF 3/16"ANNEALED GLASS WITH A.090-"PVB"INTERLAYER. K.13/16"LAMI IG:(1)LITE OF 118"OR 3/16"ANNEALED(MIN.)GLASS,3/16"OR 1/4"AIR SPACE AND 716"LAMI CONSISTING OF(1)LITE OF 3116"ANNEALED GLASS AND(1)LITE OF 3116"HEAT STRENGTHENED GLASS WITH A.090-"PVB'INTERLAYER. L.13/16"LAMI IG:(1)LITE OF 1/8"OR 3/16"ANNEALED(MIN.)GLASS,3116"OR 114"AIR SPACE AND 7/16"LAMI CONSISTING OF(2)LITES OF 3/16'HEAT STRENGTHENED GLASS WITH A.090-"PVB"INTERLAYER. 2.CONFIGURATIONS:OX,XO,XOX 3.DESIGN PRESSURES:(SEE TABLES,SHEET 3) A.NEGATIVE DESIGN LOADS BASED ON TESTED PRESSURE AND GLASS TABLES ASTM E 1300, B.POSITIVE DESIGN LOADS BASED ON WATER TEST PRESSURE AND GLASS TABLES ASTM E 1300. 4.ANCHORAGE:THE 33 1/3%STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT.SEE SHEETS 8 THROUGH 11 FOR ANCHORAGE DETAILS. 5.SHUTTERS ARE NOT REQUIRED. PRODUCT REVISED :,5.•.Plying with me Ftai& Ruildmg Code 6.FRAME AND PANEL CORNERS SEALED WITH NARROW JOINT SEALANT OR GASKET. Ez ir4[ion Dete 7��1 7.REFERENCES:TEST REPORTS FTL-0858,FTL-4859 AND FTL-5330. I ELCO TEXTRON NOKS Ay. ANSI/AF&PA NDS FOR WOOD CONSTRUCTION 11�, �eProaecl C� " ALUMINUM DESIGN MANUAL 8.THIS PRODUCT HAS BEEN DESIGNED&TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, INCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ). •. 9.FOR INSTALLATION IN THE HVHZ ABOVE 30 FT,GLASS TYPES G-L SHALL HAVE A TEMPERED I.G.GLASS CAP.BOTH THE DP AND ANCHOR QUANTITY REMAIN UNCHANGED. "PVB"=.090"BUTACITE®PVB INTERLAYER BY KURARAY AMERICA,INC. rmwey. a� a.,mba � _ 'r�'1'• � ,I�I ,,`�',. JR 05/05M8 GENERAL ADDED SPACERS TO SHEL-72. GENERAL NOTES y' Y• �-Ejj:7 .VENICE,FL3427P.O.BOX 1529ALUM.HORIZONTAL ROLLER WINDOW,IMPACT BY �� NOKOMIS,FL 34274 TIibly Better sm� 8xA.LIMILLER P.E. F.K. 1/28/ 3123M HR710 PIT$ 1 m 11 4127-10 G P.E.If 58705 21 50 21T7"I Part# Description Material 75 Kommerling 4SG TPS Spacer System 53 1/2"NOM. 55M. 76 Quanex Super Spacer nM with Hot Melt Butyl See this GLASS BITE ITE Sheet for 77 Quanex Duraseal Spacer Materials 78 Cardinal M.Edge Spacer 51 60,61,62 5165 REFERENCE TEST REPORTS:FTL-87......8&6970 118'ANNEALED OR HEAT STRENGTHENED GLASSEALED OR HEAT STRENGTHENED GLASS I .09D PVB INTERLAYER NTERLAYER 118'ANNEALED OR HEAT STRENGTHENED GLASSEALED OR HEAT STRENGTHENED GLASS 5/16'NOM. INATED 5/16"LAMINATED GLASS 7/16"LAMINATED GLASS FOR INSTALLATION IN THE HVHZ ABOVE 30 FT,GLASS i TYPES G-L SHALL HAVE A I a EXTERIOR INTERIOR TEMPERED I.G.GLASS CAP. .PVB"= BOTH THE DP AND ANCHOR j ALL SECTIONS e QUANTITY TO REMAIN � ) KURARAY BUTACITE � PVBINTERLAYER UNCHANGED. or PlIl./82-ANNEALEDLOR 21 LHFA SAFLEXsPVB INTERLAYER BY ' EASTMAN CHEMICAL COMPANY I 75-78 1 M.BITE 59 52,68,69,70,71 EALED OR HEAT STRENGTHENED GLASS 3/18'ANNEALEDOR T STRENGTHENED GLASS B INTERLAYER .090 PVB INTERLAYER i NEALEDOR HEAT STRENGTHENED GLASS 3116'ANNEALED OR HEAT STRENGTHENED GLASSMINATED 7116'LAMINATED 5/16O3/8'AIR SPACE 3/16'OR 1/d'AIR SPACE t 118'OR 3116'ANNEALED OR TEMPERED GLASS 1/8'or 3/le'ANNEALED OR TEMPERED GLASS 13/16"NOM. 13/16'NOM. 13!16"LAMI IG GLASS W/5/16"LAMI 13/16 LAMI IG GLASS W/7/16"LAMI I r 1 I ALUMINUM SILICONE HOT-MELT BUM REINFORCEMENT POLYISO- DESICCANT FILL AREA PRODUCTREWSED STRUCTURAL BUMENE es cemplyiog with the Plutide 5/16"NOM. Rnildin Cod: } SILICONE 5116"NOM. SEAL B STRUCTURAL 1/4'NOM. FOAM 3/16'NOM. SILICONE SEAL Atteplaom No/6- WITH eo- POLYISOBUMEN BUM& r WITH ROLL-FORMED WITH DESICCANT DESICCANT DESICCANT FOAM STAINLESS STEEL—\ 3 EXT.GLASS EXT.GLASS EXT.GLASStvtiemi edePlvdOM EXT.GLASS _ s i INT.GLASS INT.GLASS INT.GLASS INT.GLASS KODISPACE SUPER DURASEALO 76 XLEDGEm 7s 4SG TPS 7e SPACER19NXTn" SPACER SPACER - rr,.4er. JR oswfe G ADDED SPACERS. 1070 TECHNOLOGY ORNE GLAZ/NG DETAILS N.VENICE,FL 34275 t� P.O.eox,em SUM.HORIZONTAL ROLLER WINDOW,IMPACT NOKOMIS,FL 34274 Voibly Better > 1=U11 2 d 11 412T-10 G A.L P.E.t ILLL P.E. i F.K ?/29816 J.J. .V23rD6 E i TABLE 1. XOX(1/4,1!2,1/4)FLANGE OR INTEGRAL FIN WINDOWS_(FLANGED SHOWN.FIN WINDOWS W/SAME DLO ARE 1"SMALLER) WINDOW GLASS WINDOW HEIGHT WIDTH TYPE 26" 36" 38 318" 48" 50 518" 54" 60" 63" 8d" A,B,G,H +60.0 50.0 +60.0 -60.0 +60.0 60,4 +60.0 80,0 +60.0 150.0 +60.0 50.0 +60,0 ' -60.0 +60.0 60.0 96" A,B,G,H +60.0 -60.0 +60.0 -60.0 +60.0 ? -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +58,8 ! -58.8 +56.2 -56.2 FOR INSTALLATION IN 106 318" A,B,G,H +60-0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 50.0 +60.0 50.0 +60.0 50.0 +55.21 -55.2 +52.3 j -52.3 THE HVHZ ABOVE 34 108" A,B,G,H +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 50.0 +60.0 1 50.0 +60.0 5 ; -51.7 0.0 +54.6 -54.6 +51.7 FT,GLASS TYPES G- - L SHALL HAVE A 111" A,B,G,H +60.0 -60.0 +60.0 i -60.0 +60.0 '•: 50.0 +60.0 50.0 +60.01 +59.5 59.5 +53.6 -53.6 +50.9 1 -50.9 TEMPERED I.G.GLASS UP TO 111" C,I CAP.BOTH THE DP +60-0 -60.0 AND ANCHOR UP TO 111" DEF' QUANTITY REMAIN J,K,L +75.0 j -75.0 UNCHANGED. TABLE 2. XOX(1/3,113,113)FLANGE OR INTEGRAL FIN WINDOWS(FLANGED SHOWN.FIN WINDOWS WI SAME DLO ARE 1"SMALLER) WINDOW GLASS WINDOW HEIGHT WIDTH TYPE ALL HEIGHTS UP TO 63" TO 86 7/16" A'B'C' I G,H,I +60.01 -60.0 TO 86 7/16" D,E,F, J,K L +75.0 I -75,0 TABLE 3. OX AND XO FLANGE OR INTEGRAL FIN WINDOWS(FLANGED SHOWN.FIN WINDOWS W/SAME DLO ARE 1"SMALLER) WINDOW GLASS WINDOW HEIGHT WIDTH TYPE 26" 36" 38 3/8" d8" 50 518" 54" 60" 63" 60" A,B,G,H +75.0 -75.0 +75.0 -75.0 +75.0 + 5. . 0 - 5 7 . , . . . -75.0 66" A,B,G,H +75.0 -75-0 -7 .0 +75.07 +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 +74.2 1 -74.2 +70-21 -70.2 72" A,B,G,H +75.0 -75.0 +75.0 1 -75.0 +75.0 -75.0 +75.0 -75.0 +75.0 1 -75.0 +75.0 -75.0 +69.669.6 +65.2 65.2 PRO oucrREVISED as complying with the Florida 74" 1 A,B,G,H +75.0 -75.0 +75.0 f -75-0 +75.0 i -75.0 +75.0 -75,0 +75.0 1 -75.0 +75,0 75.0 +68.1 68.1 +63.8 63.8 13.0ding Cade Acccpm 4� ' UP T074" C,D,E,F, +75.0 -75.0 ``� mt�x I,J,K,L 3y Tvh mi GLASS TYPES:TEST REPORT F11�858(XOX),FTL4859(OX&XO)AND FTL-5330 A.5/16"LAMI-(118'A,.090,1/8"A) G. 13/16"LAMI IG-1/8"OR 3/16"A(MIN.),5/16"OR 318"AIR SPACE,5/16"LAMI-(1/8"A,.090,1/8"A) B.5116"LAMI-(1/9'A,.090,1/8"HS) H. 13!16"LAM!1G-1/8"OR 3116"A{MIN.},5116"OR 3/8"AIR SPACE,5/16"LAMI-(118"A,.090,118"HS) C.5116"LAMI-(118"HS, .090,118"HS) I. 13/16"LAMI IG-1/8"OR 3116"A(MIN.),5116"OR 31'8"AIRSPACE,5/16"LAMI-(1!8"HS,.090,118"HS) `'. -• .7 6"LAMI-(3116"A,.090,3/16"A) J.13/16"LAMI IG-1!8"OR 3/16"A(MIN.),3116"OR 114"SPACE,7/16"LAMI-(3116"A, .090,3(16"A) :• E.7116"LAMI-(3/16"A,.090,3/16"HS) K. 13/16"LAMI IG-1/8"OR 3/16"A(MIN.),3/16"OR 1/4"SPACE,7/16"LAMI-(3/16"A,.090,3/16"HS) F.7/16"LAMI-(3(16"HS,.090,3/16"HS} L.13116"LAMI IG-1/8"OR 3116"A(MIN.),3/16"OR 1/4"SPACE,7/16"LAMI-(3/16"HS,.090,3(16"HS} 611111/4 1070 TECHNOLoor oR VE DESIGN PRESSURES R VENICE,FL 34275 *� BOX _'=� � ALUM.HORIZONTAL ROLLER WINDOW,IMPACT Ors.aep>1tlr O.lna D N6xoMIS,FL34274 j/G{&j�etfer °"'.* ° ®"'r n'M'dw a. ' 228878 J,J. 3239)6 r�tna n LYNN MILLER NTS 3 a 11 4127-10 C7 P.E.p b870.5 " 27 3/8"27 3/8 27 3/8" i� MAX.DLO 54 5/16"MAX.DLO FIXED MAX.DLO MAX.DLO 1 1 VENT VENT FIXED D D 8 ' B B B A, x 0 X O X _ - _ I I I I r 110"MAX.WIDTH I.F.FRAME =1 85 7116"MAX.WIDTH I.F.FRA ME—+-� �- _II �111"MAX.WIDTH FLANGE FRAME 6 7/16"MAX.WIDTH FLANGE FRAME DETAIL B-XOX(1/4-1/2-1/4) DETAIL C-XOX(1/3-1/3-1/3) NOTE: 33 9/16"MAX. 33 9/16"MAX. 1.SEE SHEET 5 FOR VERTICAL AND HORIZONTAL SECTION DETAILS. DLO FIXED C DLO VENT 3 SEALANT OR GASKET 63"MAX. AT HEAD AND SILL ;I FLANGE A I q FRAME ALL 15 M 3/8° 56" CONFIG. MAX MAX. PRODUCT REVISED DLO ALL 15 I.F.FRAME s cmnplying with the Florida DLO ALL / I / VENTS — Oeilding Code FIXED 62"MAX. —— c xp Woos No LITES I.F.FRAME ination Ume ALL Y O I X CON IG. m'DulrProdoetC d 1 13 FLANGE FRAME C 73"MAX.WIDTH I.F.FRAME�I VIEW D-D 74"MAX.WIDTH FLANGE FRAME -{ (FRAME CORNER CONSTRUCTION) OR XO DETAILA-OX 6 Br e nr: i.Wmm 0707ECHNOLOOVDRNE LE EVATIONS N.VENICE,FL 34275 Ili ' RM4rr• �� L ALUM.HORIZONTAL ROLLER WINDOW,IMPACT P.O.BOX 1529 asenf�L, — n..`vlty p,r NOKOMIS,R 34274 VW66 Better A.LYNN MILLER.P.E. ° p FK 22&Y79 Q JJ 3N8 HR, NT.S '4 � �� 4127�0 G P.E.fi 58705 INTERIOR 37 32 35 22 39 22 16 2 EXTERIOR INTERIOR 3 21 MAX.VENT DLO MAX.FIXED DLO MAX. T DLO MAX.WIDTH(FLANGE FRAME) EXTERIOR &ISECTION B—B 17 (HORIZONTAL SECTION—XOX SHOWN WITH FLANGE FRAME) MAX. INTERIOR 17 35 32 37 HEIGHT 39 FLANGE FRAME MAX. VENT DLO Q 16 MAX. FIXED DLO I 22 MAX.FIXED DLO MAX.VENT DLO 43 MAX.WIDTH(I.F.FRAME) 21 EXTERIOR SECTION A—A (HORIZONTAL SECTION-OX SHOWN WITH INTEGRAL FIN FRAME) 24 8 22 21 41 22 PRODUCT REVISED as .plying with The Florids 2 3uilAiog Code 12 24 8 EXTERIOR INTERIOR "`P�QceNO/ OZI e. irstion Dd4 7 12 s CSG 21 �++io i ade Prodott Cwmoi� 7 EXTERIOR INTERIOR 6 10 10 SECTION C—C 42 SILL HEAD �( (VERTICAL SECTION, FLANGE FRAME) (VERTIC) ON,I.F. FRAME) (VERTICAL SECTION, LF. FRAME) �y/( 1070 TECHNOLOGY DRIVE SECTIONS N.VENICE,FL 34275 .--�— ALUM.HORIZONTAL ROLLER WINDOW,IMPACT + P.O.BOX 1529 A.LYNN MILLER P.E. � NOKOMIS.FL34274 Visibly Better s.+ Half 5 11 4127-10 G P.E.sse7os F.K. 228/06 J.J. 323/06 f rHM DWGNIREVI DESCRIPTION MATL PGT# TI'FM DWG#REVI DESCRIPTION MAT'L PGT# 1 4102 A FLANGEFRAME HEAD 6063-T6 AL 612237 66 GLASS, 13116"LAMI I&118"A(MIN),3/8'"AIR SPAM,5116"LAMI 118"'A,.090 PVH ll8"A 2 4025 SASH STOP(STD.)(ANTI LIFT CLIP) 6063-T5 AL 612244 67 13/16"LAMI IG-1/8"A(MIN. 3/8"AIR SPA 5116°LAMI 0/8"A,.090 PVB,1/8"HS) 3 #8 X 3/4 PH.PAN HEAD 7834AA 68 13/16"LAM[I&1/8"A(MIN.),3/8"AIR SPACE,5/16"LAMI(118"HS,.090 PVB,1/8"HS) 4 4053 SASH STOP COVER(SASH STOP) 6063-T5 AL_ 69 13/16"LAMI 1&3/161:4 OWN.),5/16"AIR SPACE 5116'LAMI(U8"A,.09UPVB,ll8"A) 6 4136 FLANCEFRAMESILL 6063 T6 AL 64136 70 13/16"LAMI I&3/16'.4(MIN.),5/16"AIR SPACE 5116"LAMI(1/8"A,.090PVB,1/8"HS) 7 4137 SILL ADAPTOR 6063-T6 AL 64137 71 .13/16"LAMI I&3/16"A(MIN.),5/16"AIR SPACE,5/16"LAMI(1/8"HS,.090 PVB,1/8"HS) 8 4131 ROLLERTRACK 6063-T6 AL 64131 72 13/16"LAMI I&1/8"A(MIN.),1/4"AIR SPACE,7/16"LAMI(3/16"A,.090 PVB,3/16"A 10 71298 WEEP HOLE COVER POLYPROP. 71298 73 13116"LAMI IG-1/8"A(MIN.),1/4"AIR SPACE,7116"LAMI(3/16-A-090 PVB,3/16"HS 12 1626 ADHESIVEOPIN CELL FOAM PAD ?PAD1626 74 13/16"LAMI I&1/8"A(MIN.),1/4"AIR SPACE,7/16"LAMI 3/16"HS,.090PVB,3/16-HS) 13 4002 A FLANGE FRAME JAMB 6063-T6 AL AD16 75 13/16"LAMI IG-3116"A(MIN.),3/16"AIP SPACE,7116"LAMI(3/16"A,.090 PVB,3116"A) 612225 14 4134 GASKET FOR MAINFRAME SILL JOINT 74134W/K 76 13/16"LAMI 10,3116"A(MIN.),3/16"AIR SPACE,7/16"LAMI(3/16"A,.()90 PVB,3116"HS) 77 13/16"LAMI I&3/16"A(MIN.),3/16"AIR SPACE,7116"LAMI(3/16"HS,.090 PVB,3/16-HS) 15 1155 #8 X EN AAD PN SMS 781PQA 90 1014 SCREENFRAME OR.&VER.) 3105•H14 AL 16 4110 G SCREEN ADAPTOR 6063-TS AL 64110& 91 1630 SCREEN CORNER KEY W/RINGS POLYPROP. 17 4054 B FDIEDMEETINGRAIL 6063HDT6AL 64054A 92 1631 1 SCREEN CORNER KFYW/OUTRINGS POLYPROP. 19 4066 W STP.,.187 X.230,FIN SEAL 64066E 93 1073 SCREEN SPRING ST.ST. 21 4105 SASH TOP&BOTTOM RAIL 6063-T5 AL 612240 94 1624 SCREEN SPLINE-.135 DIA.FOAM EM PVC 22 1683 W SV.,250 X.270 BACK,FIN SEAL 61683G 95 1635 ISCREEN SPLINE-.135 DLA.HARD EM PVC 23 1 225-1 ROLLER HOUSING&GUIDE 42112HD 96 SCREEN I CLOTH 24 226 BRASS ROLLER WHEELS BRASS 7BRWHL2 29 4128 HORIZONTAL ROLLER SASH TOP GUIDE POL'YPROP. 44128N 32 4006 D ISASHMEETINGRAIL 6063HS-T6 AL 64006 2.710 33 1235 W STP..170 X.270 BACK,FIN SEAL 67S 160 35 1096 SWEEP LATCH DIE-CAST 71096 36 1016 #8 X.625 PH.FL.SMS 7858 37 4126 SASH SIDERAIL 6063-T5 AL 641M 38 1683 W STP.,.250 X.270 BACK,FIN SEAL 61683G 2.624 39 7070 BULB WEATHERSTRIP.187 X 275 67070KK •062 40 LIFT RAIL COVER CAP 74078"C"L ORR 41 4139 I.F.FRAMEHEAD 6063-T6 AL 64139 I.F.FRAME HEAD 42 4140 I.F.FRAME SILL 6063-T6 AL 64140 41 #4139,6063-T6 RA 43 4141 IF.FRAME JAMB 6063-T6 AL 64141 50 GLAZING SILICONE,DOW 899,995 OR DIVALENT 51 1224 VDM CIAZINGBEAD BULB(THICK) 6TP247W K PRODUCMEVISED .e"mplying i iiih Nie Florida 52 1225 VINYL GLAZINGBEAD BULB(THIN) 6TP248K Building Code 2.794 Accepzan_C No ��O•f� Q;f 53 4039 B GLAZING BEAD-5116"' 6063-T5 AL 64039H pirotion pmc �`3✓SGr 54 4044 B GLAZINGBEAD-5116"W/GRILL KIT 6063-TS AL 644703 .0sz 3152 Dy 55 4222 A G.AZINGBEAD-7/16" 6063-T5 AL 64222 Mani �� 56 985 C GLAZINGBEAD-7/16"W/GRILL KIT 6063-T5 AL 6985 .062 59 4067 ( AZINGBEAD-13116'" 6063-T5AL �7 1.989 60 GLASS 5/16"LAMI(1/8"A_090 PVB1/8"A) 4g LF.FRAME JAMB 61 5/16"LAMI(I/8"A_090 PVB,U8"HS) #4141,6063-T6 62 " 5116"LAMI(1/8"HS,.090 PVB,1/8"HS) 63 " 7/16"LAMI(3/16"A_090 PVB,3/16'A) L2.710--j 64 7/16'LAMI 3/16"A_090 3/16"HS) 42 IF.FR 65 1140 7/16"LAMI(3116"HS,.090 PVB,3/16'HS) . LL #41R 60AME E SILL Ramer oom eax 1070 TECHNOLOGY DRIVE�vr PARTS LIST s>Mz R N.VENICE,FL 34275 trrc P.O.BOX 1529 ALUM.HORIZONTAL ROLLER WINDOW,IMPACT Dem NOKOMI5.FL 34274 MT/tslb>?y A.LYNN MILLER P.E9f13lDB XR7fo NTS 6 a 1! 4127--111 (j P.E.p 537115 - i I-�1.513� .062 1.187 I— P44 738 3.152 1.37 062 L7 O SASH STOP COVER 1.273 r .062 3.090 4 #4053,6063T5 L1.1x22 2.710{ ��-2.710--�{ O FLANGE FRAME HEAD O O �I-�—z 764--{ FLANGE FRAME SILL FRAME SILL ADAPTER #4102A,6063-T6 #4136,6063-T6 #4137,6063-T6 1.363 y I 062 061 1 61' 7 c—i 062 13 FLANGE FRAME JAMB —4—.062 � � I rrr ---Iii #4002A,6063-T6 .490 �1�.� .43 F1.461 Fes-1.403 AS 6063-T5Oe O STHORIZ#ROLL06ER6TRACK 17 FIXE#DSMBEEDTGINDGRAIL O # .062 2.27 ,062 �1.1 7 2.326 � .D51.183 I.062 1.349 11 � .676 I I I- 1291+y 1.349{ —�{ 1.081 � 1.096 � SASH TOP&BOTTOM RAIL 32 SASH MTG.RAIL 37 SASH SIDE RAIL 53 GLAZING BEAD,5/16" PRODUCTg,,jjh 6D 21 as romplyipg with the Flnida #4133,6063-T5 #4006D,6063HS-T6 #4126,6063-T5 #40396,6063-T5 6uiidiag Cod, Acceptmnz Na I�-� l •TG' Expiration Date, .050 1 titiaaii eP:Ddact Controi� .678 .6776 678 .683 ,050 4001 llL��� 050 . .050—&- 1.096 T—i— —I 1.096—��— 1.115 1.097bl 54 GLAZING BEAD,5/16" 55 GLAZING BEAD 7/16" 56 GLAZING BEAD,7/16" 59 GLAZING BEAD,13/16" #4044B,6063-T5 #4222A,6063-T5 #985C,6063-T5 #4067,6063-T5 (USED W/GRILL KIT) (USED W/GRILL KIT) RewtlBy. an H: ReNaMs Om4me Pe ar pg� Rer�ean 1070 TECHNOLOGY DRIVE EXTRUSIONS N.VEN ICE,FL 34275 Raa4 ar. am: ReN.+bru � ALUM.HORIZONTAL ROLLER WINDOW,IMPACT .. •, P.O.BOX 1529 esmmmaa, — — y„ft,yz p —.y pae. NOKOMIS,FL34274 Vi bly Better A LYNN MILLER,P.E. F.K ?/28/06 J.J. 3/23/06 i HR7f0 Half 7 a 11 4127-10 G P.E.a 58705 C ANCHOR QUANTITIES,XOX 114-112-1/4)WINDOWS TABLE 4 NOTES: GLASS TYPES A,B,C,G,H,I GLASS TYPES D,E,F,J,K.L 1. ANCHOR TYPES: ANCHOR TYPE 2,3,WOOD 2,CONC 1,CONC 2,3,WOOD 2,CONC 1,CONC 1-1/4"ELCO TAPCONS 2-1/4"ELCO SS4 CRETE-FLEX 3 412 STEEL SCREWS(G5) 8 SUBSTRATE ZONES ZONES ZONES ZONES ZONES ZONES m !m im :m !m !m 2.GLASS TYPES: `m m m m m 1 m A.5116"LAMI-(1/8°A,.090,1/8"A) FOR INSTALLATION IN THE HVHZ ABOVE 30 WINDOW 512E HEAD 8 SILL;2 HEAD 8 SILL Ig HEAD&SILLS HEAD&SILL:2 HEAD&SILLS HEAD&SILL• FT,GLASS TYPES G-L SHALL HAVE A W N > !� !9 B.5116"LAMI-(1/8"A,A90,1/8"HS) C.5116"LAMI-(1/8"HS,.090,118"HS) TEMPERED I.G.GLASS CAP.BOTH THE DP AND 53.125X 38.375 1+C2+1+C2+1 2 1+C2+1+C2+11 2 1+C2+1+C2+1 2 1+C2+1+C2+1 1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 i 2 D.7/16"LAMI-(3/16'A,.090,3116"A) ANCHOR QUANTITY REMAIN UNCHANGED. 48,000 1+C2+1+C2+1!3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+11 3 1+C2+1+C2+1s 3 1+C2+1+C2+1 1 3 E.7116"LAMI-(3/16"A,.D90,3/16"HS) 50.625 1+C2+1+C2+1'3 1+C2+1+C2+11 3 1+C2+1+C2+11 3 1+C2+1+C2+1`3 1+C2+1+C2+1!3 1+C2+1+C2+1 3 F.7/16"-AMI-IG-1 8"OR 0,3/16"(MI I G.13116"LAMI IG-1/8"OR 3/16"A(MIN.),5/16"OR 3/8"SPAC E,5116"LAMI-(118"A,.090,1/8"A) 54.000 1+C2+1+C2+1 j 3 1+C2+1+C2+1l 3 1+C2+1+C2+1 i 3 1+C2+1+C2+1 3 1+C2+1+C2+113 1+C2+1+C2+1 i 3 H.13/16"LAMI IG-1/8"OR 3116"A(MIN.),5116"OR 318"SPACE,5/16'LAMI-(1/8"A,.090,1/8"HS) 60.000 1+C2+1+C2+1 3 1+C2+1+C2+1?3 1+C2+1+C2+11 3 1+C2+1+C2+1 3 1+C2+1+C2+1!3 1+C2+1+C2+1!3 I. 13/16"LAMI IG-118"OR 3/16"A(MIN.),5116'OR 318"SPACE,5116"LAMI-(1/8'HS,.090,118"HS) J.13/16"LAMI IG-1/8"OR 3/16"A(MIN.),3/16"OR 114"SPACE,7/16"LAM]-(3/16"A,.090,3/16"A) 63.000 1+C2+1+C2+11 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+11 3 1+C2+1+C2+1!3 1+C3+1+C3+1 3 K.13116"LAMI IG-1/8"OR 3/16"A(MIN.),3/16"OR 114"SPACE,7/16"LAMI-(3116"A,.090,3116"HS) 60.000x 38.375 1+C2+1+C2+1 i 2 1+C2+1+C2+11 2 1+C2+1+C2+1'2 1+02+1+C2+11 2 1+C2+1+C2+1 i 2 1+C2+2+C2+1 2 L. 13/16"LAMI IG-1/8"OR 3/16"A(MIN.),3116"OR 1/4"SPACE,7/16"LAMI-(3116"HS,.090,3/16"HS) 11 48.000 1+C2+1+C2+ii 3 1+C2+1+C2+1 3 1+C2+1+C2+1 j 3 1+C2+1+C2+11 3 1+C2+1+C2+1il 3 1+C2+2+C2+11 3 3.WINDOW ANCHOR QUANTITIES ARE PER ADJACENT TABLE AND BASED ON THE FOLLOWING 50.625 1+C2+1+C2+11 3 1+C2+1+C2+1 3 1+C2+1+C2+1!3 1+C2+1+C2+1 3 1+C2+1+C2+11 3 1+C2+2+C2+113 DIMENSIONS. FOR WINDOW SIZES NOT SHOWN,GO TO NEXT LARGER WINDOW IN TABLE. 54.000 1+C2+1+C2+11 3 1+C2+1+C2+1i 3 1+C2+1+C2+113 1+C2+1+C2+1i 3 1+C2+1+C2+1 3 1+C2+2+C2+ii 3 HEAD&SILL: 101/2"MAX.ON EACH SIDE OF MEETING RAIL CENTERLINE. 60.000 1+C2+1+C2+1 3 1+C2+1+C2+11 3 1+C2+1+C2+1 3 1+C2+1+C2+1 X 3 1+C2+1+C2+t i 3 1+C3+2+C3+1 i 3 25 3/4"MAX.FROM CORNERS. JAMBS: 9"MAX.FROM CORNERS AND 22 112"MAX.O.C. 63.000 1+C2+1+C2+1!:.3 1+C2+1+C2+1i 3 1+C2+1+C2+1i 3 1+C2+1+C2+1I 3 1+C2+1+C2+1 3 1+C3+2+03+11 3 TABLE KEY: 74.000x 38.375 1+C2+2+02+11 2 1+C2+1+C2+1 2 1+C2+2+02+112 1+C2+2+C2+1 2 1+C2+2+C2+1i 2 1+C2+2+C2+1`:2 X O X 48.000 1+C2+2+C2+113 1+C2+1+C2+1'3 1+C2+2+C2+1 3 1+C2+2+C2+11 3 1+C2+2+C2+1i 3 1+C2+2+C2+ii 3 1+C3+4+C3+1 3 -ANCHOR QUANTITY PER JAMB 50.625 1+C2+2+C2+11 3 1+C2+1+C2+1'i 3 1+C2+2+C2+11 3 1+02+2+C2+1.3 1+C2+2+C2+11 3 1+C2+2+C2+1 j 3 HEAD AND SILL ANCHOR QUANTITY. 54.000 1+C2+2+C2+11;3 1+C2+1+C2+11 3 1+C2+2+C2+11 3 1+C2+2+C2+1 3 1+C2+2+C2+1 1 3 1+C3+2+C3+1 13 A CLUSTER OF(3)ANCHORS CENTERED AT EACH MEETING RAIL PLUS(1) 60.000 1+C2+2+C2+1 3 1+C2+1+C2+li 3 1+C2+2+C2+11 3 1+C2+2+C2+1:3 1+C2+2+C2+1i 3 1+C3+2+C3+11 3 ANCHOR AT EACH OPERABLE VENT 63.000 1+C2+2+C2+1i 3 1+C2+1+02+1i 3 1+C3+2+C3+1!3 1+C3+2+C3+11:3 1+C2+2+C2+1 13 1+C3+2+C3+1 i 3 PLUS(4)ANCHORS AT FIXED SECTION. 04.000x 38.375 1+C2+2+C2+11 2 1+C2+2+C2+1 1 2 1+C2+2+C2+1 2 1+C2+2+C2+1':211+02+2+r,2+112 1+C2+3+C2+1 j 2 (12)ANCHORS TOTAL AT HEAD AND SILL. 48.000 1+C2+2+C2+1j 3 1+C2+2+C2+1;3 1+C2+2+C2+li 3 1+C2+2+02+1!3 1 1+C2+2+C2+1i 3 1+C3+3+C3+113 (3"MIN.O.C.ANCHOR SPACING) 50.625 1+C2+2+02+1i 3 1+C2+2+C2+1 3 1+C2+2+C2+1;3 1+C2+2+C2+1 3 1+C2+2+C2+1i 3 1+C3+3+C3+1I 3 54.000 1+C2+2+C2+11 3 1+C2+2+C2+11 3 1+C2+2+C2+11 31 1+C2+2+C2+11 3 1+C2+2+C2+11 3 1+C4+3+C4+11 3 25 3/4"max. -+{[---3"MIN. 60.000 1+C2+2+C2+11 3 1+C2+2+C2+113 1+C3+2+03+1�3 1+C3+2+C3+1i 3 1+C2+2+C2+1 3 1+C4+3+C4+l�3 63.000 1+tom+2+C2+11 3 1+C2+2+C2+1i.3 1+C3+2+C3+1 3 1+C3+2+C3+1.3 1+C2+2+C2+1 3 1+C4+3+C4+1[3 9"REF. X 0 X r I PRODUCTREVISED 106.375 x 38.375 1+C2+2+C2+1?2 1+C2+2+C2+11 2 1+C2+3+C2+1 j 2 1+C2+3+C2+1 1 2 1+C2+3+C2+Iii 2 1+C2+4+C2+1 12l us complying eriN Nrc Florida 48.000 1+C2+3+C2+11 3 1+C2+2+C2+11 3 1 1+C3+3+C3+1.3 1+C3+3+C3+li 3 1+C2+3+C2+1'3 1+C3+4+C3+1j 3 Buildug C:odc 1 I MTG.RAIL,TYP. a ceplmce No/�o-O IQ-.13 50.625 1+C2+3+C2+1;3 1+C2+2+C2+11 3 1+C3+3+C3+1�3 1+C3+3+03+1 3 1+C3+3+C3+1.3 1+C3+4+C3+1i 3 EXAMPLE CLUSTER W/QTY.OF(3)ANCHORS 54.000 1+C3+3+03+11 3 1+C2+2+C2+1i 3 1+C3+3+C3+1 13 1+C3+3+C3+1�3 1+C3+3+C3+1i 3 1+C4+4+C4+1I,3 (SHOWN IN TABLE KEY ABOVE) bfiam; ? don 60.000 1+C3+3+C3+1j 3 1+C2+2+C2+1E 3 1+C4+3+C4+1 3 1+C4+3+C4+1�4 1+C3+3+C3+1i 3 1+C4+4+CA+1i 3 63.000 1+C3+3+C3+1;3 1+C2+2+C2+1j 3 1+C4+3+C4+11 3 1+C4+3+C4+1 4 1+C4+3+C4+1i 3 1+C5+4+CS+1i 31 25 3/4"MAX. 111.000x 38.375 1+C2+3+C2+1!2 1+C2+2+C2+1i 2 1+C2+3+C2+1j 2 1+C2+3+C2+113 1+C2+3+C2+1 2 1+C2+4+C2+ti 21 1--3- IN.P 48.000 1+C2+3+C2+11 3 1+C2+2+C2+11 3 1+C3+3+C3+1i 3 1+C3+3+03+113 1+C2+3+C2+ti 3 1+C3+4+C3+11 3 9"REF. X 0 X 50.625 1+C2+3+C2+1j 3 1+C2+2+C2+113 1+C3+3+C3+11 3 1+C3+3+C3+1;3 1+C3+3+C3+11 3 1+C3+4+C3+113 T 54.000 1+C3+3+C3+11 3 1+C2+2+C2+11 3 1+C3+3+C3+11:3 1+C3+3+C3+11 3 1+C3+3+C3+11 3 1+C4+4+C4+11 3 1 60.000 1+C3+3+C3+1j 3 1+C2+2+C2+1 3 1+C4+3+C4+11 3 1+C4+3+C4+1i 4 1+C3+3+C3+1i 3 1+C4+4+C4+11 3 MTG.RAIL,TYP. 63.000 1+C3+3+C3+1i 3 1+C2+2+C2+1i 3 1+C4+3+C4+113 1+C4+3+C4+1i 4 1+C4+3+C4+1 i 3 1+C5+4+C5+11 4 EXAMPLE CLUSTER W/QTY.OF(4)ANCHORS B..dBy AM R,„,,s 1070TECHNOLOGYDRIVE ANCNORAGESPACING,XOX 1/4-1/2-1/4 N.VENICE,FL 34275 T� . ALUM.HORIZONTAL ROLLER WINDOW,IMPACT P.O.Box 1529 AcX7 _ NOKOMIS,FL 34274 1/&ibly Better A.LYNN MILLER P.E. °F.K � �6 HR7f0 NTS 8 4127-10 d �� G P.E.#58705 ANCHOR OUANT1TIES XOX 113-113-1/3 WINDOWS TABLE 5 NOTES: GLASS TYPES A,B,G,H GLASS TYPES C.D,E,F,I,J,K,L ANCHOR TYPE .2,3,WOOD 2,CONC 1,CONC 2,3,WOOD 2,CONC 1,CON. 1. ANCHOR TYPES: &SUBSTRATE ZONES ZONES ZONES ZONES ZONES ZONES 1-1/4"ELCO TAPCONS 2-1/4"ELCO SS4 CRETE-FLEX 3-#12 STEEL SCREWS(G5) !y iN iN 'N iN im 2.GLASS TYPES: WINDOW SIZE HEAD&SILL 12' HEAD&SILL!T HEAD&SILL g HEAD&SILL HEAD&SILL i HEAD&SILL:2A.5116'LAMI-(118"A,.090,118"A) FOR INSTALLATION IN THE HVHZ ABOVE 30 W v H ; •: ! 1� B.5/16"LAMI-(1/8"A,.090,1/8'HS) FT,GLASS TYPES G=L SHALL HAVE A 48.000 x 38.375 1+102+1+C2+1!2 1+C2+1+C2+1!2 i+C2+1+C2+1 2 1+C2+1+C2+1!2 1+C2+1+C2+1 2 1+C2+1+02+1!2 C.5/16"LAM[-(118"HS,.090,118"HS) TEMPERED I.G.GLASS CAP.BOTH THE DP AND 48,000 1+102+1+102+i!3 1+102+1+102+1!3 1+102+1+102+i 13 1+C2+1+02+113 i+102+1+102+1!3 1+102+1+102+11 3 D.7/16"LAM[-(3116"A,.090,3/16"A) ANCHOR QUANTITY REMAIN UNCHANGED. E.7/16'LAMI-(3/16"&.090,3116"HS) 50.625 1+02+1+C2+113 1+C2+1+C2+1;3 1+C2+1+C2+113 1+C2+1+C2+11 3 1+C2+1+C2+1!3 1+C2+1+C2+1 3 F.7/16"LAMI-(3/16"HS,.090,3/16"HS) 54.000 1+C2+1+C2+11 3 1+C2+1+C2+11 3 1+C2+1+C2+1;3 1+C2+1+C2+11 3 1+C2+1+C2+11.3 1+C2+1+C2+1;3 G.13/16"LAMI IG-1/8"OR 3/16"A(MIN.),5116"OR 318"SPACE,5116"LAMI-(1/8"A,.090,1/8"A) 60,000 1+102+1+102+11 3 1+102+1+102+11 3 1+102+7+102+11 3 1+102+1+102+1 3 1+102+1+102+1!3 1+102+1+102+11 3 H.13/16"LAMI IG-1/8"OR 3116"A(MIN.),5116"OR 318"SPACE,5116"LAMI-(1/8"A,.090,1/8"HS) 63.000 1+102+1+C2+11 3 1+C2+1+C2+1;3 1+C2+1+C2+1=.3 1+C2+1+02+1 3 1+C2+1+C2+113 1+C3+1+C3+11:3 I. 13/16"LAMI IG-118"OR 3/16"A(MIN.),5/16"OR 3/8'SPACE,5116"LAMI-(1/8"HS,.090,1/8"HS) J.13116"LAMI IG-1/8"OR 3/16"A(MIN.),3/16"OR 1/4"SPACE,7/16"LAMI-(3/16"A,.090.3116"A) 53.125 x 38.375 1+C2+1+C2+1;2 1+C2+1+C2+11 2 1+C2+1+C2+1 2 1+C2+1+C2+112 1+C2+1+C2+11 2 1+C2+1+C2+112 K.13116"LAMI IG-1/8"OR 3116"A(MIN.),3/16"OR 1/4"SPACE,7/16"LAMI-(3/16"A,.090,3/16"HS) 48.000 1+C2+1+C2+11 3;1+C2+1+C2+1 3 1+C2+1+C2+1 311+02+1+C2+113 1+C2+1+C2+1!3 1+C2+1+C2+1!3 L. 13/16"LAMI IG-1/8"OR 3/16"A(MIN.),3/16"OR 1/4"SPACE,7/16"LAMI-(3116"HS,.090,3/16"HS) 50.625 1+102+1+102+113 i+102+1+102+11 3 1+102+1+102+1 3 1+102+1+102+1!3 1+102+1+102+1!3 1+102+1+102+1 i 3 3.WINDOW ANCHOR QUANTITIES ARE PER ADJACENT TABLE AND BASED ON THE FOLLOWING 54.000 1+102+1+102+11 3 1+102+1+102+1!3 1+102+1+102+11 3 1+102+1+102+11 3 1+102+1+102+11 3 1+102+1+102111 3 DIMENSIONS. FOR WINDOW SIZES NOT SHOWN,GO TO NEXT LARGER WINDOW IN TABLE. 60.000 1+C2+1+C2+11;3 1+C2+1+C2+11 3 1+C2+1+102+1!3 1+C2+1+C2+1;3 1+C2+1+C2+11 3 1+C3+1+C3+11 3 63.000 1+C2+1+C2+1!3 1+C2+1+C2+11 3 1+C2+1+C2+1 3 1+C2+1+C2+11 3 1+C2+1+C2+1;3 1+p+1+C3+1;3 HEAD&SILL: 10 1/2"MAX.ON EACH SIDE OF MEETING RAIL CENTERLINE 60.000 x 35.375 1+C2+1+C2+11 2 1+C2+1+C2+1;2,1+C2+1+C2+11.2 1+C2+1+C2+1!2 1+102+1+C2+1;2 1+C2+1+C2+1 12 25 314"MAX.FROM CORNERS JAMBS: 9"MAX.FROM CORNERS AND 221/2"MAX.O.C. 48,000 1+C2+1+C2+1!3 1+C2+1+C2+11 3 1+C2+1+C2+11:3 1+C2+1+C2+11 3 1+C2+1+C2+1!3 1+02+1+C2+11:3 TABLE KEY: 50.625 1+C2+1+C2+1!3 1+C2+1+C2+11 3 1+C2+1+C2+11 3 1+C2+1+C2+1!3 1+C2+1+C2+T.3 1+C2+1+C2+1•;3 X 0 X 54.000 1+C2+1+C2+1!3 1+C2+1+C2+1;3 1+C2+1+C2+11 3 1+C2+1+C2+1;3 1+C2+1+02+1;3 1+C3+1+C3+1!3 1+C3+1+C3+1 3 -ANCHOR QUANTITY PER JAMB 60.000 1+102+1+102+1!3 1+C2+1+C2+1!3 1+C2+1+C2+11 3 1+C2+1+02+11 3 1+C2+1+C2+113 1+p+1+103+11 3 63.000 1+C2+1+C2+1'3 1+C2+1+C2+11 3 1+C2+1+C2t11 3 1+C3+1+C3+1!3 1+102+1+102+1`3 1+p+1+.3+11 3 HEAD AND SILL ANCHOR QUANTITIES 66.000 x 38.375 1+C2+1+C2+1;2 1+C2+1+C2+11 2 1+C2+1+C2+11 2 1+C2+1+C2+11 2 1+C2+1+102+1 2 1+C2+1+C2+11:2 A CLUSTER OF(3)ANCHORS CENTERED ON EACH MEETING RAIL PLUS(1) 48.000 i+C2+1+C2+11 3 1+C2+1+C2+1!3 1+C2+1+C2+11 3 1+C2+1+C2+11 3 1+C2+1+C2+113 1+C2+1+C2+11 3 ANCHOR AT EACH OPERABLE VENT 50.625 i+C2+1+C2+11.3 1+C2+1+C2+11 3 1+C2+1+C2+1 3 1+C2+1+C2+1!3 1+C2+1+C2+11 3 1+C3+1+103+1;3 PLUS(1)ANCHORS AT FIXED SECTION. 54.000 1+C2+1+C2+11 3 1+C2+1+C2+1!3 1+C2+1+C2+11 3 1+C2+1+C2+11 3 1+C2+1+C2+11 3 1+C3+1+C3+1!31 (9)ANCHORS TOTAL AT HEAD AND SILL. 60.000 1+C2+1+C2+11 3 1+C2+1+C2+1!3 1+C2+1+102+11 3 1+C3+1+C3+1!3 1+C2+1+02+1!3 1+C3+1+C3+11 3 (3-MIN.O.C.ANCHOR SPACING) 63.000 i+C2+1+C2+11 3 1+C2+1+C2+1!3 1+C3+1+C3+1 3 1+C3+1+C3+1'3 1+C2+1+C2+11 3 1+C3+1+C3+113 74.000 x 38.375 1+C2+1+C2+1;2 1+C2+1+C2+11 2 1+C2+1+C2+11 2 1+C2+1+C2+112 1+C2+1+C2+112 1+C2+1+C2+11 2 25 314"MAX. 48.000 1+C2+1+C2+11:3 1+102+1+102+1;3 1+102+1+102+11 3 1+102+1+102+i';.3 1+102+1+102+1<3 1+p+1+103+1;3 �{!-3-MIN. 50.625 1+C2+1+C2+113 1+C2+1+C2+11 3 1+C2+1+C2+113 1+C2+1+02+1!3 1+C2+1+C2+1!3 1+C3+1+C3+1!31 54.000 1+102+1+102+1!3 1+102+1+102+1;3 1+102+1+102+1!3 1+102+1+102+13 1+102+1+G2+1 3 1+C3+1+C3+113 9„REF. X O X 60.000 1+C2+1+C2+1;3 1+C2+1+C2+1;3 1+C3+1+C3+1 3 1+C3+1+C3+11 3 1+C2+1+C2+1j 3 1+C3+1+103+1;3 ?.O p('TR6V15E0 complying w'eth the Florida 63.000 1+102+1+102+113 1+102+i+102+11 3 1+pt1+103+1;3 1+C3+1+p+1':,3 1+102+1+102+1!3 1+C3+1+C3+1!31 8::ldi�lg Code 84.000x 38.375 1+C2+1+C2+112 1+C2+1+C2+1i 2 1+C2+i+C2+1;2 1+C2+1+C2+113 1+C2+1+C2+11 2 1+C2+1+C2+1 2 MTG.RAIL,TYP. gcceprauceNo Ian- /�21 48.000 1+C2+1+C2+11 3 1+C2+1+C2+11 3 1+C2+1+C2+11 3 1+C2+1+C2+11 3 1+C2+1+C2+1;3 1+C3+1+C3+11 3 EXAMPLE CLUSTER W/QTY.OF(3)ANCHORS in ration Darn �} 50.625 1+C2+1+c2+1!3 1+C2+1+C2+113 1+C2+1+C2+11 3 1+C2+1+C2+1,3 1+C2+1+C2+1!3 1+C3+1+C3+1!3 (SHOWN IN TABLE KEY ABOVE) es' t"tiami e�rodneLC 54.000 1+C2+1+C2+11 3 1+02+1+C2+1;3 1+C3+1+C3+1;3 1+C3+1+C3+1;3 1+C2+1+C2+i;3 1+C3+1+C3+1[3 60.000 1+C2+1+C2+1.3 1+C2+1+C2+1;3 1+03+1+103+1!3 1+C3+1+C3+1.4 1+C3+1+p+1':3 1+p+1+C3+1 i 31 25 3/4"MAX. 63.000 1+C3+1+C3+11 3 I 1+C2+1+C2+1;3 1+C3+1+C3+11.3 1+C3+i+C3+1;4 1+C3+1+C3+1;3 1+C4+1+C4+1'4 1 1/2"TYP. .... . MIN. 86.437x 38.375 1+C2+1+C2+11:2 1+C2+1+C2+1'2 1+C2+1+C2+112 1+C2+1+C2+1i 3 1+C2+1+102+1 2 1+102+1+102+1!2 •- 9"REF. >' o 48.000 1+C2+1+C2+1:3 1+C2+1+C2+1!3 1+C2+1+C2+113 1+C2+1+C2+113 1+C2+1+C2+li3 1+C3+1+03+113 XA_`j X 50.625 1+C2+1+C2+113 1+C2+1+C2+11 3 1+C2+1+C2+1;3 1+C2+1+C2+113 1+102+1+102+1;3 1+p+1+103+113 54.000 1+C2+1+C2+11 3 1+102+1+102+1 3 1+C3+1+C3+11 3 1+C3+1+C3+1!3 1+C2+1+C2+11 3 1+C3+1+C3+11 3 60.000 1+C2+1+C2+1!3 1+C2+1+02+11 3 1+C3+1+C3+11 3 1+C3+1+C3+1':4 1+C3+1+C3+1;3 1+C4+1+C4+114 MTG.RAIL,TYP. - 63.000 1+103+1+c3+1;3 1+102+uC2+r•;3 1+p+1+103+11 3 1+103+1+p+1i 4 1+103+1+p+1;3 1+G3+1+Ca+11 a EXAMPLE CLUSTER W/ QTY.OF(4)ANCHORS Jnr 1070 TECHNOLOGY DRIVE ANCHORAGE SPACING"XOX1/3-1/3-1/3 N.VENICE,FL 34275 , ALUM.HORIZON TAL ROLLER WINDOW,IMPACT 1 P.O.BOX 1529 e�tiabat �e �e u�xa 1b,. o�4o0e �: NOKOMIS,FL 34274 Visibly Batey A.LYNN MILLER P.E. FK 7I18NB JJ 923/08 HR7f0 NTS 9 > 11 4127-10 G P.E.p55705 f ANCHOR QUANTITIES,XO&OX WINDOWS TABLE 6 NOTES: GLASS TYPES A,B,G,H GLASS TYPES C,D,E,F,I,J,K,L 1. ANCHOR TYPES: ANCHOR TYPE 2,3,WOOD 2,CONC 1,CONC 2,3,WOOD 2,CONC 1,CONC 1-1/4"ELCO TAPCONS 2-114"ELCO SS4 CRETE-FLEX 3-#12 STEEL SCREWS(G5) &SUBSTRATE ZONES ZONES ZONES ZONES ZONES ZONES o f Q J Q J i 6) Q J Q J U) Q J ' 2.GLASS TYPES: m m 1 DD Q -1 j co Q I I m " m A.5/16"LAM[-(118"-A,.090,1/8"A) FOR INSTALLATION IN THE HVHZ ABOVE 30 WINDOW SIZE y g to W 55 m lyl W ! W In ' 2 W v) B.5/16"LAMI-(1/6"A-090,1/8"HS) FT,GLASS TYPES G-L SHALL HAVE A W V H 2 e6 Q 3:.d ' _,� ' 2 oa !'¢ _ ,� Q = ' C.5116"LAM[-(118"HS,.090,1/8"HS) TEMPERED I.G.GLASS CAP.BOTH THE DP AND D.7116"LAMI-(3116"1,.090,3/16"A) ANCHOR QUANTITY REMAIN UNCHANGED. 37.000 x 38.375 1+C2+1 2 1+C2+1 2 1+C2+1 i 2 1+C2+1 i 2 1+C2+1 2 1+C2+1 2 E.7/16"LAMI-(3/16"A,.090,3116"HS) 48.000 1+C2+1 3 1+C2+1 3 1+C2+1 1 3 1+C2+11 3 1+C2+1• 3 1+C2+1 3 F.7116"LAMI-(3/16"HS,.090,3116"HS) G.13/16"LAMI IG-1/8"OR 3/16"A(MIN.),5116"OR 3/8"SPACE,5116"LAMI-(1/8"A,.090,1/8"A) 50.625 1+C2+1 3 1+C2+1 3 1+C2+1 j 3 1+C2+1• 3 1+C2+1 1 3 1+C2+1 3 H.13/16"LAMI IG-1/8"OR 3116"A(MIN.),5/16"OR 318'SPACE,5116"LAMI-(1/8"A,.090,1/8"HS) 54.000 1+C2+1 3 1+C2+1 3 1+C2+1' 3 1+C2+1; 3 1+C2+1; 3 1+C2+1 3 I. 13116'LAMI IG-118"OR 3116"A(MIN.),5/16"OR 3/8"SPACE,5/16"LAMI-(118"HS,.090,118"HS) 60.000 1+C2+1 3 1+C2+1 3 1+C3+1 j 3 1+C2+1' 3 1+C2+1; 3 1+C3+1 3 J.13!16"LAMI IG-116"OR 3/16'A(MIN.),3116'OR 1/4'SPACE,7/16"LAMI-(3116"A,.090,3116-A) K.13116"LAMI IG-1!8"OR 3116"A(MIN.),3/16"OR 1/4"SPACE,7/16"LAM[-(3116"1,.090,3/16"HS) 63.000 1+C2+1 3 1+C2+1 3 1+C3+1 i 3 1+C2+1 i 3 1+C2+11 3 1+C3+1 3 L. 13116"LAMI IG-1/8"OR 3/16"A(MIN.),3116"OR 1/4"SPACE,7/16"LAMI-(3/16'HS,.090,3116"HS) 48.000 x 38.375 1+C2+1 2 1+C2+1 2 1+C2+1 2 1+C2+1 2 1+C2+1j 2 1+C2+1 2 3.WINDOW ANCHOR QUANTITIES ARE PER ADJACENT TABLE AND BASED ON THE FOLLOWING 48.000 1+C2+1 3 1+C2+1 3 1+C2+1! 3 1+C2+1 i 3 1+02+1 13 1+C2+1 3 DIMENSIONS. FOR WINDOW SIZES NOT SHOWN,GO TO NEXT LARGER WINDOW IN TABLE. 50.625 1+C2+1 3 1+C2+1 3 1+C3+1 3 1+C2+1 3 1+C2+1! 3 1+C3+1 3 HEAD&SILL: 10 112"MAX.ON EACH SIDE OF MEETING RAIL CENTERLINE. 54.000 1+C2+1 3 1+C2+1 3 1+C3+1 3 1+C2+11 3 1+C2+11 3 1 1+C3+1 3 18 3/4"MAX.FROM CORNERS. 60.000 1+C3+1 3 1+C2+1 3 1+C3+1 3 1+C3+1; 3 1+C2+11 3 1+C3+1 3 JAMBS: 9"MAX.FROM CORNERS AND 22 1/2"MAX_O.C. 63.000 -1+C3+1 3 1+C2+1 3 1+C3+1 1 3 1+C3+1 i 3 1+C2+1! 3 1+C3+1 3 TABLE KEY: O X 53.125 x 38.375 1+C2+1 2 1+C2+1 2 1+C2+11 2 1+C2+1 2 1+C2+1 12 1+C2+1 2 2+C3+2 3 ANCHOR QUANTITY PER JAMB 48.000 1+C2+1 3 1+C2+1 31+C3+1i 3 1+C2+1i 3 1+C2+11 3 1+C3+1 3 50.625 1+C2+1 3 1+C2+1 3 1+C3+1; 3 1+C2+1( 3 1+C2+1 13 1+C3+1 3 HEAD AND SILL ANCHOR QuaNr[T[Es A CLUSTER OF(3)ANCHORS 54.000 1+C3+1 3 1+C2+1 3 1+C3+1! 3 1+C3+1 3 1+C2+1 1 3 1+C3+1 3 CENTERED ON THE MEETING RAIL 60.000 1+C3+1 4 1+C2+1 3 1+C3+1 3 1+C3+1' 4 1+C2+1 3 1+C3+1 3 PLUS(2)ANCHORS AT OPERABLE 63.000 1+C3+1 4 1+C3+1 3 1+C4+1 3 1+C3+1 3 1+0 4 1+C3+1'• 4+1 3 VENT AND FIXED SECTION:•.(7) I ANCHORS TOTAL AT HEAD AND SILL. 60.000x 38.375 1+C2+1 3 1+C2+1 2 2+02+2j 2 1+C2+1; 3 1+C2+11 2 2+02+2 2 48.000 1+C2+1 3 1+C2+1 3 2+C3+2; 3 1+C2+1 j 3 1+C2+1 j 3 2+C3+2 3 (3"MIN.O.C.ANCHOR SPACING) 50.625 1+C3+1 3 1+C2+1 3 2+C3+2j 3 1+C3+1i 3 1+C2+1j 3 2+C3+2 3 183/4"MAX. 54.000 1+C3+1 4 1+C2+1 3 2+C3+2 j 3 1+C3+1 4 1+C2+1 1 3 2+C3+2 3 F--3"MIN. 60.000 1+C3+1 4 1+C3+1 3 2+C4+21 4 1+C3+11 4 1+C3+1. 3 2+C4+2 4 g"REF. 63.000 1+C3+1 4 1+C3+1 3 2+C4+2 4 1+C3+1; 4 1+C3+1':, 3 2+C4+2 4 X 0 PRODUCT REVISED 66.000 x 38.375 2+C2+2 3 1+C2+1 2 2+C2+2. 3 2+C2+2 3 1+C2+1! 2 2+C2+2 3 w mniplyin With the Florida MTG.RAIL 13.ildiog Code . 48.000 2+C2+2 4 1+C2+1 3 2+C3+21 3 2+C2+2j 4 1+C2+1 3 2+C3+2 3 Ane9,eae,No 161 50.625 2+C3+2 4 1+C2+1 3 2+C3+2:i 3 2+C3+214 1+C2+1 3 2+C3+2 3 EXAMPLE CLUSTER W/QTY.OF(3)ANCHORS `at'0R '1021 54.000 2+C3+2 4 1+C2+1 3 2+C3+2 4 2+C3+2' 4 1+C2+1 3 2+C3+2 4 (SHOWN IN TABLE KEY ABOVE) E> ,* Mi i ede 9rodmi trot i'1 60.000 2+C3+2 4 1+C3+1 3 2+C4+2 4 2+C3+2; 4 1+C3+1j 3 2+C4+2 4 U 63.000 1+C3+1 4 1+C3+1 3 2+C4+2 4 2+C3+21 4 1+C3+1 3 2+C4+2 4 18 3/4"MAX. 1 1/2"TYP. 74.000 x 38.375 2+C2+2 3 2+C2+2 2 2+C2+2 3 2+C2+21 3 2+C2+21 2 2+C2+2 3 F-3"MIN. 46.000 2+C3+2 4 2+C2+2 3 2+C3+2! 4 2+C3+2j 4 2+C2+2 3 2+C3+2 4 1 9'.REF. 50.625 2+C3+2 4 2+C2+2 3 2+C3+2 C3 4 2+ +2' 4 2+C2+2; 3 2+C3+2 4 X O 54.000 2+C3+2 4 2+C3+2 3 2+C4+2 4 2+C3+21 4 2+C3+2 3 2+C4+2 4 MTG.RAIL ' 60.000 2+C3+2 4 1+C3+1 3 2+C4+2i 4 2+C3+2; 5 2+C3+21 3 2+C4+2 4 - 63.000 2+C3+2 4 1+C3+1 3 2+04+21 4 2+C4+2j 5 2+C3+2i 4 2+C4+2 5 EXAMPLE CLUSTER W/QTY.OF(4)ANCHORS ( I y f 6 1070 TECHNOLOGY DRIVE ANCHORAGE SPACING,OXAND XOWINDOWS N.VENICE,FL 34275 r� '• ��- ALUM.HORIZONTAL ROLLER WINDOW,IMPACT P.O.BOX 1520 yy oy,,. ane n.wyw -' A.LYNN MILLER P.E. 0-w- o"' ad>d NOKOMIS,FL 34274 Wmbly Behr HR710 NTS 10 - 11 4127-10 G P.E.V 587H F.K. 2123/08 J.J. 3/23178