HomeMy WebLinkAboutWind Load Calculation Castle
f
Impact Windows
it
FACTORY DIRECT SINCE 1969 X
COMPLETE HURRICANE PROTECTION SOLUTIONS
7089 Hemstreet Place
West Palm Beach,FL 33413 800.643.6371
Property Information Building Information
Owner: FERRONE,JERRY Wind Zone: 160 MPH.
Address: 8804 ONE-PUTT PLACE Exposure Category: C
PORT SAINT LUCIE,FL 34986 Minimum Building Dimension: 40 ft.
Mean Roof Height: 16 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 270.25 146 7 26.6 -29.5
fF ')
JU�3
PER,1:1-T 'N,G
ct t ur i�Cot.rtj', i=i-
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.5th Edition(1014)Florida Building Code.
Page 1 of 1
' Customer: FERRONE WorkOrder Number: 04102017015 N0301
Unit No. Wall Opening Opening Shutter Shutter Slat Anchor
Pressure Width Height Width Height Length Spacing
1 -29.5 270.25 146 290.25 144.5 141.25 6"o.c.
4"o.c.