HomeMy WebLinkAboutWind Load Calculation MCastle
Impact Windows
FACTORY DIRECT SINCE 1969
COMPLETE HURRICANE PROTECTION SOLUTIONS
7089 Hemstreet Place
West Palm Beach,FL 33413 800.643.6371
Property Information Building Information
Owner: CHRISTOPHER,JOAN Wind Zone: 165 MPH.
Address: 7380 GULLOTTI PLACE Exposure Category: D
PORT SAINT LUCIE,FL 34952 Minimum Building Dimension: 35 ft.
Mean Roof Height: 15 ft.
Risk Category: II
Design Pressure Calculations
Opening Location DeviceDevice Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 84.25 92 7 38.5 -42.1
2 Int 84.25 92 7 38.5 -42.1
JU�31�'
P E 8:411:-Tl it
St. Lucie Cot:nty, F!_
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.51h Edition(2019)Florida Building Code.
Page 1 of 1
Customer: CHRISTOPHER WorkOrder Number: 05112017012 N0301
Unit No. Wall Opening Opening Shutter Shutter Slat Anchor
Pressure Width Height Width Height Length Spacing
1 -42.1 84.25 92 103.5 99 95.75 6"o.c.
6"o.c.
2 -42.1 84.25 92 103.5 99 95.75 6"o.c.
6'b.c.