HomeMy WebLinkAboutWind Load Calculation TIGHT1918 Corporate Drive WII ® -® WS Boynton Beach,FL 33426 Ph.561-922-6747 Fax.561-292-3562 Property Information Building Information Owner: Susan Risoldi Wind Zone: 170 MPH. Address: 212 Ramie Lane Exposure Category: C Port Saint Lucie,FL 34952 Minimum Building Dimension: 43 ft. Mean Roof Height: 20 ft. it Jul Risk Category: II Design Pressure Calculations 1[=,7ng Location Device Device Device Max Positive IF Max Negative Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 25 62 7 40.0 -43.4 -- - __.... ....._.... _ _. - 11 2 Int 25- 62 _ _ 40.0 - -43.4 3 Int 25 62 7 40.0 -43.4 4 Int 25 62 7 40.0 -43.4 5 Int 25 62 7 40.0 -43.4 6 End 73 62 7 37.2 47.8 Prepared in accordance wilh:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.51h Edition(2014)Florida Building Code. Page 1 of 1 A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Comer Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS NUMBER or Interior OR DOOR TYPE NUMBER (+)PSF (-)PSF (+)PSF (-)PSF TESTED DIMENSIONS MULLION REQ Y/N SIZE REQ Y/N/NA 1 Int W 7/8"Lanii IG 15-0618.02 55 55 40.0 -43.4 53x77 25x62 Y N 2 Int W 7/8"Lami IG 15-0618.02 55 55 40.0 -43.4 5307 25x62 Y N 3 Int W 7/8"Lami IG 15-0618.02 55 55 40.0 -43.4 5307 25x62 Y N 4 Int W 7/8"Lami IG 15-0618.02 55 55 40.0 -43.4 5307 25x62 Y N 5 Int W 7/8"Lami IG 15-0618.02 55 55 40.0 -43.4 5307 25x62 Y N 6 End W 7/8"Lami IG 15-0618.03 55 55 37.2 -47.8 74x63 73x62 N N z _ , ENGINEERING XP ?OSS Design Wind Pressure(PMAx+, PMAX-): ASCE 7-10, Ch.30.4.2130.6.2 160 SW 12th AVENUE, #106 h560 ft. h>60 ft. DEERFIELD BEACH, FL 33442 Max Positive Pressure(PMAx+) PMAx+ = gh(6c GCppos + GCpI) PMAx+ = gh(Oc GCppos + GCp) PH:(954)354-0660 FAx:(954)354-0443 WWW.ENGEXP.COM Max Negative Pressure(PMAx-) PMAx-= gh(Oc GCpneg- GCO) PMAx-= gh(Ac GCpneg-GCpI) Wind Load Calculation ASCE 7-10 Chapter 30 Wind Loads-Components and Device Calculations:ASCE 7-10, Chapter 30,All Subsections Cladding Size Elevation Area AreaT Pmax+ PmaX- 5th Edition(2014)Florida Building Code # (W z H) Zone (ft) (ft2) (ft2) K, qZ GCP+ GCP- (Ib/ft2) (Ib/ft2) Site Information 1 25 x 62 Int 7 10.76 8.90 0.85 53.38 1.0 -1.1 40.0 -43.4 2 25 x 62 Int 7 10.76 8.90 0.85 53.38 1.0 -1.1 40.0 -43.4 Owner: Susan Risoldi 3 25 x 62 Int 7 10.76 8.90 0.85 53.38 1.0 -1.1 40.0 -43.4 Wind Speed(V): 170 MPH 4 25 x 62 Int 7 10.76 8.90 0.85 53.38 1.0 -1.1 40.0 43.4 5 25 x 62 Int 7 10.76 8.90 0.85 53.38 1.0 -1.1 40.0 -43.4 Exposure Category: C Velocity Pressure Coef.(Kh): 0.90 6 73 x 62 End 7 31.43 12.34 0.85 53.38 0.9 -1.2 37.2 -47.8 ASCE 7-10 Ch.30.3.1 Table 30.3-1 Directionality Factor(Kd): 0.85 Topographical Factor(KzT): 1.0 Structure Information Risk Category: 11 Building Classification: Enclosed Int.Pressure Coef.(GCpi): 0.18 ASCE 7-10 Table 2611-1 Mean Roof Height(h): 20 ft. Roof Slope(0): Sloped Roof Slope Coefficient(0c): 1.0 Min.Building Dim.(L): 43 ft, End Zone Distance(a): 4.3 ft. 1.THISNFORMATIDN6NTENDEDTOPROVIDEDESIGNPRESSURESFORTHERIRPOSEOFTHENSTALLATCNOFGLA EDUN!TS&OPENING PROTECTION AS PROPOSED AND PROVID ED SyOTHERS.NO CERTFICATION.EITHER GORDON DIBATTISTO,P.E. EXPRESSEDORMPLIED.60FFERED ASTO THEVALIDRYOR A I;ABLRYOFANYPROPOSED SYSTEMOR COMPONENTUSED ALONG WITH THESERTESSURESALL PRODUCTSSHML BENSTALLED N STRCTACCORDANCEWRH Prepared in accordance with: VALID FLORIDARTODUCTAPPROVALSAND MUSTMEETTHESE PRESSURESFOR THEGNI NSZELIMITATCNS FL PE StS28 ASCE 7-10.Section 30. Wind Loads-Components and 2.NO CERTFCATCN OR REVIEW BOFFFAEO THATTHERTOPOSEDUNRSMEETANYEGRESSREOUREMFNTS.ALLEGRESS6SUESARETOBEADDRESSEDBYTHEPERMRTNGCONTRACTORANDTHELOCALBULDNGOFFCW. p D.THEHOST STRUCTURE6ASSUMED TO SEADEOUATETO WFRNSTAND THELOADSMPOSED BYTHB DESIGN ASWORKREM-CESEXSTNG FRAMNG,OR OPENINGS DESIGNED AND CERTIFIED BYAN ENGINEER OF RECORD(EOR). CladdingTHECONTRACTORMULDNG OFFICIAL SHALL VErFYTHATTHESUBSTRATEEIFOSED DURNG WORKISSOUND FOR NSTALLATCN OFTHISSYSTEM F DEFCENCIESAAEFOUND N THES(6TNG HOST STRUCTURE THMENGNEER ORTHEEORSHALLBENOTFED BEFORECONTNUNG CONSTRUCTION AND RESERVESTHERIGHTTO RE-NSPECTAND REEV&UATE DES13N.NOWARRANTY,EITIIEA EXPRESSED OR MPLED,6CONTANED HEREIN. 5th Edition 2014 Florida BuildingCode 4.DMENSCNSARESHOWNTOLLUSTRATEDESIGNFORCESIWDOTHERDFSIGNCRRERWTHEYMAYVARYSLIGHTLY,TOTHEIX TTHATTHEOPENNGARFASNOTSMAI.LERTH-5%OFTHEENGNEEREDDESIGN. �� ( ) CONTRACTOR BTO VERFVALL FIELD DMENSIONSPRCR TO NST&LATION. JEDENG!NEER o�� S. ENGINEER SEAL AFFIXED HER ETOVXIDATESSTRUCTURAL DESIGN ASSHOWN ONLY.USEOFTHBSPECFCATCN BYCONTRACTOR.,t,LNDEMNFES&SAVESHARMLESSTH6FNGNEEH FOR ALLCOST&DAMAGESNCLUDNG 0 2017 E-Tempest.coin LEG&FEES&APPELLATEFEES RESULTING FROM MATERIA.FPBRCATCN,SVBTEM ERECTION,&CONSTRUCTION PRACTCESSEYOND THATWHCH ISCALLED FOR BYLOCAL,STATE&FEDERAL CODES&FROM DEVIATIONSOF THIS PLAN. ID:stornrtight-P5989 6.ENGNEERNGE ESSHASNOTVSMTHSJOBSRENFORMMNCONTMEDHERENEB DONCONTRACTORSUPPLEDDATAANDMEABUREMENTSENGNEERNGF RESSSHALLNOTBEHEIDRESPONSBLEORLVBLEN C #9885 ANY WAV FOR ERRONEOUSOR INACCURATE DATAOR MEASUREMENTSWORKSRALL BEFELD VERFED PRIOR TO CONSTRUCTCN.ENGNEERNG EJFRESSSHALLEENOTFED MND GIVEN AN OPPORTUNRYTO RE-EVALUATEOUR WORKUPONDrCOVERYOFANYNACCURATENFORMATCNMIORTOMDDFCATCNOFEJ(6TNOFELDCONDMNSMIDFABRCATCNANDNSTALLATCNOFMATERW-S WITHSEAL 05/12/2017 Page 1 of 1 T.EXCEPTASEXPRFSSLYPROVIDED HER&N,NOADDRCNALCEATF CP CNSOfl AFFWMATCNSARE NT@0E0. 'ALTERATION ADDrMN 0R0THERMARKNGSTOT ISDOCUM TARENOTR MITTEDMNDNV&DATEOU Re TFCATCN' VALID FOR JOB ONLY