HomeMy WebLinkAboutWind Load Calculation PARADISE EXTERIOR` "Building Our Quality Reputation One Customer At A Time SCC131150472 Property Information Building Information Owner: GARY&JANET PICKLESIMER Wind Zone: 170 MPH. Address: 250 SHINN RD Exposure Category: C FORT PIERCE,FL 34945 Minimum Building Dimension: 35 ft. Mean Roof Height: 12 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 70 78 7 34.5 -37.7 Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.Sth Edition(2014)Florida Building Code. Page 1 of 1 A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Comer Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING MULLION SHUTTERS NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF DIMENSIONS REQ Y/N SIZE REQ Y/NINA 1 Int Door I Lami IG FL11103.1 60 60 34.5 -37.7 96 x 96 7008 'No No