HomeMy WebLinkAboutWind Load Calculation MCastle Impact Windows FACTORY DIRECT SINCE 1969 � -_s 1 COMPLETE HURRICANE PROTECTION SOLUTIONS 7089 Hemstreet Place West Palm Beach,FL 33413 800.643.6371 Property Information Building Information Owner: RUEB,ROY Wind Zone: 165 MPH. Address: 1904 LYNX DRIVE Exposure Category: D FORT PIERCE,FL 34949 Minimum Building Dimension: 40 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 End 155.25 72.5 7 37.4 -46.3 2 End 341 112.5 7 34.0 -39.4 3 End 132 111 7 36.7 -44.8 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.51h Edition(2014)Florida Building Code. Page 1 of 1 Customer: RUEB WorkOrder Number: 01262017003 N0301 Unit No. Wall Opening Opening Shutter Shutter Slat Anchor Pressure Width Height Width Height Length Spacing 1 -46.3 157.75 72.5 172.25 79.5 76.25 9"o.c. 9"o.c. 2 -39.4 342.25 112.5 354.75 115 111.75 9"o.c. 9"o.c. 3 -44.8 132 111 153.625 117.5 114.25 9"o.c. i