HomeMy WebLinkAboutProduct Approval 398 E.Dania Beach.Blvd
BUILDING DROPS Suite 338
Dania Beach, FL 33004
A Perfect,Solution in.Every Drop 954.399.8478 PH
Certificate of Authorization.29578 954:744.4738 FX
contact@buildingdrops.com
Product Evaluation Report
Of
17
' r tt JELD-WEN, inc.
�` ta Coiffours Steel Door, Wood Edge .SUN '2'011
fpr PEl LI1171 HIG
St. Lucie County, FL
Florida Product Approval
Report 2 1.
Current Florida Building Code
Method: 1 —A (Certificate)
Category: Exterior Doors
Sub—Category: Swinging Exterior Door Assemblies
Product: Contotaw Steel Door, Wood Edge
Material: Steel/Wood
Product Dimensions: 74"x81.75"
74"x 805"
6.4.5"x 95.25"
64.5"x 94.5"
Prepared For:
r1F.i:D-WEN, hic..
3737 Lakeport blvd.
Klamath malls, OR-97601 �1rrlrri;rri1
�ES F. 01
Prepared by: _�` �'e-•�\.. R��l�'
:'
Hernies Norero,.P.E. •: o
Florida Professional Engineer#73778
Date: 10/27/2014 = T T
Contents:
Evaluation Report Pages 1—4 ON i
Digitally signed'by Hermes F.Norero,PE.
Reason:I am approving this.document Hermes,Norero,P.E.
Date:_2014.11.11 09:50:46.-05'00' Florida No.73778
BUILDING DROPS
A Perfect Solution in Every Drop Date: 10/27J2014
Report.No: 3291
Certificate of Authorization:29578
Manufacturer: JELD-WEN,inc.
Product Category: Exterior Doors
Product Sub-Category: Swinging Exterior Door Assemblies
Compliance Method: State Product Approval Method(1)(a)
Product.Name: Contours Steel Door.,Wood Edge
(Impact Rated-Doors Only)
74"x 81.75"
74"x 80.5"
64.5"x 95.25"
64.5"x 94.5"
Scope: This is a Product Evaluation Report issued by Hermes Norero,P.E.(FL#73778)for Jeld-Wen Inc.
based on Method.1a of the State of Florida Product Approval,Florida Department of Business and
Professional Regulation-Florida Building Commission.
Hermes Norero,P.E.does not have nor will acquire financial interest in the company manufacturing
or distributing the product or in any other entity involved in the approval process of the product
named herein.
This product has been evaluated for use in locations adhering to the current Florida Building Code.
See Installation Instructions 1W162009,signed and sealed by Hermes'Norero,P.E.(FL#73778)for
specific use parameters.
Limits of Use:
1. This product has,been evaluated and'is in compliance with the current Florida Building Code,
excluding the"High Velocity Hurricane Zone"(HVHZ).
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into
substrate material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind borne debris protection this product complies with
Section 1609.1.2 of the current Florida Building Code and does not require an impact
resistant covering on single and double door systems without a sidelite or transom,in all
Wind Zones.Single and double door systems with a.sidelite or transom do not require an
impact resistant covering,in Wind Zones 3 or less. Florida approved impact resistant shutters
are required for sidelites and transom.
4. Site,conditions that deviate from the details of drawing JW162009 require further
engineering analysis by a licensed engineer or registered architect.
5. See Installation Instructions JW162009 for size and designpressure limitations.
Hermes Norero,P.E.
Florida No.73778
Page 2 of 4
L
/7
BUILDING DROPS
� A Perfect Solution in Every Drop Date: 10/27/2014
y Report NO: 3291
Certificate of Authorization:29578
Quality Assurance: The manufacturer has demonstrated compliance of products in accordance with the
Florida Building Code for manufacturing under a quality assurance program audited
by an approved quality assurance entity through National Accreditation&
Management Institute,Inc.(FBC Organization#QUA1789).
Performance Standards: The product described herein has been tested per:
• ASTM E 283-04
• ASTM E 330702
• ASTM E 331700
• ASTM E 1886-05
ASTM E 1996-05b
Referenced Data:
1. Product Testing performed by Quality Testing Inc.
'(FBC Organization#TST7638)
Report#-SJW2009-199,Report Date:1/18/2010
SJW2009-200,Report Date:.1/18/2010
2. Quality Assurance
National Accreditation and Management Institute
(FBC Organization#:QUA1789)
Hermes Norero,P.E.
Florida No.73778
Page 3 of 4
BUILDING DROPS
A Perfect Solution in Every Drop hater 10/27J2014
Certificate of Authorization:29578 Report No: 3291
Installation: 1. Approved anchor types and substrates areas follows:
Through Frame Installation:
A. For two by(2X)wood buck substrate,use#10 Wood Screw type installation anchors of
sufficient length to achieve a minimum embedment of 1.50"into.the wood substrate.
B. For concrete or masonry substrate where one by(1X),non-structural,wood bucking is
employed,use 3/16"diameter ITW Tapcon type concrete screw.anchors of sufficient
length to achieve minimum embedment of 1.25" into concrete or masonry.
C. For concrete or masonry substrate where wood bucking is NOT employed,use.3/16"
diameter ITW Tapcon type concrete screw anchors of.sufficient length to achieve
minimum embedment of 1.25"into concrete or masonry.
Refer to Installation:Instructions(JW162009)foranchor spacing and more details of the installation
requirements.
Design Pressure:
Design Pressure*
Positive 55.PSF
Negative 55 P5F
*Product has not been rated for water infiltration.if authority having jurisdiction requires that
product meets this requirement,.productshall be used when installed at location protected by
Overhang such that overhang,(OH)ratio=OH length/OH height is 1.0.
Hermes Norero,P.E.
Florida No.73778
Page 4 of 4