Loading...
HomeMy WebLinkAboutProduct Approval { a� EXTERIOR RESEARCH&DESIGN,LLC. JUN 7 201?� Certificate of Authorization 119503 T PER t-TING 353 CHRISTIAN STREET,UNIT#13 • RINI�Y;� � St. Lucie COLnty, FL OXFORD,CT 06478 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT GAF Evaluation Report 01506.01.08-1121 1 Campus Drive FL10124-1119 Parsippany,NJ 07054 Date of Issuance:01/03/2008 Revision 21:08/26/2016 SCOPE: This Evaluation Report is:issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014)-Florida Building Code sections.noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. I,I CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes: TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may displayed in advertising literature. If any,portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. 'Prepared by:. �itytrr, :a �'�_�•,���.sArS?4'05~tai:_ Robert J.M.Nieminen,P.E. ry S • �, The facsimile seal appeadng was authorized by Robert Nieminen, t-S x�jjj,S� P.E.on 08/26/2016.This does not serve as an electronically signed Florida Registration No.59166,Florida DCA ANEI983 document.Signed,sealed hardcoples have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinityl ERD does'not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. c ' } TRINITY i ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE:. Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building.Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/ Conditions of.Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4,R905.2.3 Physical Properties ASTM D1970 2009 1507.2:5,R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008 1507.2.7.1,R905.2.6.1 Wind Resistance TAS 107 1995 3. REFERENCES: Entity Examination Reference Date GAF(PDM 1915) Letter of Equivalency Seal-A-Ridge Impact Resistant IR 01/13/2012 PRI(TST 5878) Physical Properties GAF-025-02-01 03/27/2002. PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004 PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005 PRI(TST 5878) Physical Properties GAF-324-02-01 12/01/2011 PRI(TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013 UL(TST 1740) ASTM D3462 93NK6295 11/29/1993 UL(TST 1740) ASTM D3462 99NK43835 01/12/2000 UL(TST 1740) TAS 107 94NK9632 03/29/2000 UL(TST 1740) ASTM D3462 01NK06632 02/02/2001 UL(TST 1740) ASTM D31.61.1 TAS 107 01NK9226 05/21/2001 UL.(TST 1740) ASTM D3161 01NK37122 12/18/2001 UL(TST 1740) ASTM D3462 01NK37122 12/19/2001 UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002 UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002 UL(TST 1740) ASTM D3161 03CA5367 03/11/2003 UL(TST 1740) ASTM D3462 03NK26444 10/17/2003 UL(TST 1740) ASTM D3462 04NK1385G 06/07/2004 UL(TST 1740) ASTM D3161 04NK13850 06/23/2004 UL(TST 1740) ASTM D3161 04NK30546 03/10/2005 UL(TST 1740) ASTM D3462 04NK22009 05/06/2005 UL(TST 1740) ASTM D3161 04NK22009 05/09/2005 UL(TST 1740) ASTM D3462 05NK27924 02/10/2006 UL(TST 1740) ASTM D3161 OSNK27924 02/11/2006 UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006 UL(TST 1740) ASTM D3161,D3462 06CA18074 06%16/2006 UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006 UL(TST 1740) ASTM D3462 06CA31603 12/01/2006 UL(TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006 UL.(TST 1740) ASTM D3161 07NK05228 03/13/2007 UL(TST 1740) ASTM D3161 06CA31611 04/04/2007 UL(TST 1740) ASTM D3161 06CA61148 04/09/2007 UL(TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007 UL(TST 1740) ASTM D3161,D7158,D3462 08CA061ob 03/13/2008 UL(TST 1740) ASTM D3161,D3462 07CA55908 04/01/2008 Exterior Research and Design,LLC. Evaluation Report 01506.01.08-1121 Certificate of Authorization 119503 FL10124-1119 Revision 21:08/26/2016 Page 2 of 6 i QOTRINITYIERD Entity Examination Reference Date UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009 UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009 UL(TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009 UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009 UL(TST 1740) ASTM D3161,D7158,D3462 10CA35554 03/05/2010 UL(TST 1740) ASTM D3161,D7158,D3462 10CA13686 05/15/2010 UL(TST`1740) ASTM D3462 10CA07264 05/27/2010 UL(TST.1740) ASTM D3462 IOCA11953 10/29/2010 UL(TST 1740) ASTM D3161,D7158,D3462 1ONK11951 10/30/2010 UL(TST.1740) ASTM D3161,D7158,D3462 1ONK12070 11/04/2010 UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010 UL(TST 1740) ASTM D3161,D7158,D3462 10CA53934 03/31/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/2011 UL(TST 1740) ASTM 03161,D7158,D3462 11CA47919 12/03/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011 UL,LLC.(TST 9628) ASTM D3462 12CA34891 10/12/2012 UL,LLC..(TST 9628) ASTM D3161,D7158,D3462 12CA58151, 02/15/2013 UL,LLC.(TST 9628) ASTM D3161 12CA38083 02/26/2013 UL,LLC.(TST 9628) ASTM D3161 13CA32332 06/18/2013 UL,LLC.(TST 9628) ASTM D8161 13CA37934 08/02/2013 UL,LLC.:(TST 9628) ASTM D3161,D7158,03462 4786875675 07/17/2015 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4787434542 05/17/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mobile,AL 12/28/2015 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Myerstown,PA 02/23/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tuscaloosa,AL 02/26/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Michigan Cty,IN 03/02/2016 UL,LLC.(QUA 9625) QualityControl Inspection Report,R21,Shafter,CA 02/18/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Savannah,GA 02/24/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Minneapolis,MN 02/09/2016 UL,LLC'.:(QUA 9625) Quality Control Inspection Report,R21,Mt.Vernon,IN 02/09/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Baltimore,MD 03/01/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tampa,.FL 02/29/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Dallas,TX02/17/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Ennis,TX 02/03/2016 UL,LL.C.(QUA 9625) Quality Control Inspection Report,1121,Fontana,CA 03/03/2016 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Marquis® WeatherMax®, Royal Sovereign® .and Sentinel® are a fiberglass reinforced 3-tab. asphalt roof shingles. 4.1.2 Camelot®, Camelot® II, Fortitud.eTm, Glenwood'"'., Grand Canyon®, Grand Sequoia®, Grand Sequoia° IR, Grand Sequoia® ArmorShieldT'", Monaco®, Sienna®, Timberline® American Harvest®; Timberline® ArmorShieldTM II,Timberline®Natural Shadow®,Timberline HD®,Timberline®Cool Series®,Timberline Ultra HD®and Woodland®are fiberglass reinforced, laminated asphalt roof shingles. 4.1.3 Slatelinem is a fiberglass reinforced 5-tab asphalt roof shingle. 4.2 Hip&Ridge Shingles: 4.2.1 Seal-A-Ridge® Ridge Cap Shingles, Seal-A-Ridge® IR Impact-Resistant Ridge Cap Shingles, Seal-A-Ridge® ArmorShieldTm Ridge Cap Shingles and Timbertex®Premium Ridge Cap Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R21 Certificate of Authorization#9503 FL10124-1119 Revision 21:08/26/2016 Page 3 of 6 i TRINITY ERD 4.3 Accessory Starter Strias: 4.3.1 Pro-Start®Eave/Rake Starter Strip Shingles and:WeatherBlockerlm Premium Eave/Rake Starter Strip Shingles are starter strips for asphalt roof shingles. 4.3,2 QuickStart® Peel & Stick Starter Roll is a is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS modified bitumen starter strip, nominal 9-inch x 33 ft roll,for use with asphalt shingles with exposure of 6- inch or less. 4.3.3 StarterMatchrm Sharter Strip Shingles are.color-coordinated starter strips for use with Grand Canyon® and Grand Sequoia® series asphalt shingles. StarterMatchTm are installed as the second starter for Grand Canyon®and Grand Sequoia®series installations. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation.Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5_4 Wind Classification: 5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class.F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd=150 mph (V,,it= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 The GAF hip &ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161;Class F,indicating the shingles are acceptable for use in all wind zones up to Vasd=150 mph(Vint=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C.Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.2 Starter Shingles.or Starter Strip: 6.2.1 Installation of Pro-Start Eave/Rake Starter Strip Shingles, WeatherBlocker Premium Eave/Rake Starter Strip Shingles and QuickStart Peel&Stick Starter Roll shall comply with the GAF current published instructions. 6:3 Asphalt Shingles: 6.3.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: Camelot,Camelot II, Grand Canyon,Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield, and Woodland require minimum five(5)nails per shingle. Slateline requires minimum six(6)nails per shingle. Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R21 Certificate of Authorization#9503 FL10124-1119 Revision 21:08/26/2016 Page 4 of 6 I TRINITY'ERD 6.3.2. Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.4 Hip&Ridge Shingles: 6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles,Seal-A-Ridge IR Impact-Resistant Ridge Cap Shingles and Seal- A-Ridge ArmorShield Ridge Cap Shingles shall comply with the manufacturer's current published instructions with a minimum two(2)nails, minimum 3/8-inch head diameter,per shingle and nominal 0.25-inch diameter beads of Henkel"Loctite PL S30 Roof& Flashing Sealant". 1LSu Sealant 1° (292mm) 1" Sellante (25 mm) (25 M Enduit d dtancheite A�w., ...., (305 mm) Nail FIClavo 6 5/8"-7 5/8" Clouer (168-194 mm) 12" (30.5 mm) 6.4.2 Installation of Tiimbertex Premium Ridge Cap Shingles shall comply with the manufacturer's current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and beads of Sonneborn NP1 Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant. 1 Via" �e&lam (2:;tnrrt} ?25 rnn�,+ 1=rtct�ic ci'e�nch¢s'bF� �a k9R�tr s WIJ- dI„; G,x 'S71i£Ir (205 ern) r ftin; r 1291 r,� s r"fft) 6.4.3 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. Exterior Research and Design,LLC. Evaluation Report 01506.01.08-1121 Certificate of Authorization#9503 FL10124-1119 Revision 21:08/26/2016 Page 5 of 6 r y / v ^—^v�"``_� `�/ K �K�UU`�k�U 0 \ ` 7. LABELING: | 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1SO7'2.7.1/R9O5.2.8.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building,Official or Authority Having Jurisdiction in order toproperly evaluate the installation of this.product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: ULLLC—Q8Ag62G;(847)664']281 - END 0FEVALLIATIONREPORT' '. Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-R21 a���� mu�a��Avmo�om�mm�3 Revision o1:om/2a/2nza Page sofe