HomeMy WebLinkAboutProduct Approval 37 95d,
3?00 sf>�
>e
3��xsos/�
�o
s
37xo (v X
37kSo Y
BASS
(9523)
�( 3? x xG
2T GAA . .
3W-k*
2s
37x5o*V 37 V-501%,
(1, C iti a rtc( d&,KA s EAST COAST ALUMINUM
PRODUCTS,INC:,
`fi b f:Sapj yon Sf: 913 Edwards Road
Fort Pierce,FL 34982
f4 A-etad4 er/ -3 61 el 6 (772)464-7504 283-5650
I
FlAda Building Code Online Page 1 of 3
I
n r o L!n�F ,
trach f epzTntq BCIS Home Log In User Registration l Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff'� BCIS Site Map Links �V search
Busines n productApprova!
Professional * USER:Public User
Regulation
Product Approval Menu>Product or Application Search>A ion Li >Application D it
FL# FL1435-R17
Application Type Revision
Code Version 2014
Application Status Approved
*Approved by PR.Approvals by DBPR shall be reviewed and ratified
by the POC a r-the Commission if necessary.
Comments
Archived
Product Manufacturer PGT Industries
Address/Phone/Email 1070 Technology Drive
North Venice,FL 34275
(941)486-0100 Ext 22318
druark@pgtindustries.com
Authorized Signature ]ens Rosowski
jrosowski@pgtindustries.com
Technical Representative ]ens Rosowski
Address/Phone/Email 1070 Technology Drive
Nokomis,FL 34275
(941)486-0100 Ext 21140
jrosowski@pgtindustries.com
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Single Hung
Compliance Method Certification Mark or Listing
Certification Agency Keystone Certifications,Inc.
Validated By Steven M. Urich,PE
Validation Checklist-Hardcopy Received
Referenced Standard and Year(of Standard) Standard I Year
AAMA/WDMA/CSA 101/IS2/A440 2011
AAMA/WDMA/CSA 101/IS2/A440 2005
AAMA/WDMA/CSA 101/IS2/A440 2008
ANSI/AAMA/WDMA 101/I.S.2/NAFS 2002
ASTM E1886 2005
ASTM E1996 2012
ASTM E283 2004
ASTM E330 2002
Equivalence of Product Standards
Certified By
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsbCUITKe120D... 4/5/2016
GENERAL NOTES: ANCHOR LOCATIONS P ING
1)THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO COMPLY WITH 53-1 - 52-1/8"MAX.BUCK
THE FLORIDA BUILDING CODE FOR THE DESIGN PRESSURES LISTED.
--52-1/8'MAX.BUCK 6•MAX 5'MAX
2)WOOD BUCKS DEPICTED AS 1X ARE LESS THAN 1-112-THICK.1X WOOD BUCKS
ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SOLID CONCRETE.WOOD9,M -------
BUCKS DEPICTED AS 2X ARE 1.112'THICK OR GREATER ATTACHMENT METHOD OF� _
WOOD BUCKS SHALL BE DONE BY OTHERS. I I
3)SEE TABLE FOR MINIMUM EDGE DISTANCE FROM CENTER OF ANCHOR TO ( / I CNAX /
SUBSTRATE EDGE(EXCLUDING FINISH OR STUCCO). BUCK
4)SHIM EACH ANCHOR LOCATION WHERE THE PRODUCT IS NOT FLUSH TO THE I I 6" AX
SUBSTRATE,USING SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS. -'(� '
5)ANCHORS SHALL BE COATED OR CORROSION RESISTANT AS APPROPRIATE F R T I j 75"
SUBSTRATE MATERIAL.DISSIMILAR MATERIALS SHALL BE PROTECTED AS 17'MAX. I I MAX. '
REQUIRED TO PREVENT REACTIONS.ALUMINUM SHALL BE PROTECTED FROM I I
BUCK '
DISSIMILAR MATERIALS AS SPECIFIED IN THE FLORIDA BUILDING CODE.
1 I 76"
6)ADHESIVE SEALANT SHALL BE USED BETWEEN SUBSTRATE AND FLANGE OR IN. � / � MAX. /
OVERALL SEALINGIFLASHING STRATEGY FOR WATER RESISTANCE OF TIP-TO-
INSTALLATION SHALL BE DONE BY OTHERS. I I
I I TIP
7)MATERIALS USED FOR ANCHOR EVALUATIONS WERE SOUTHERN PINE,2.7 KSI
I I
CONCRETE AND CONCRETE MASONRY UNITS COMPLYING WITH ASTM C-90.
GLAZING COMPLIES WITH ASTM E1300. 9"MAX I I
---- ---- ---- 5'
8)THE 113 STRESS INCREASE WAS NOT USED IN THIS ANCHOR EVALUATION.THE
1.6 LOAD DURATION FACTOR WAS USED FOR THE EVALUATION OF WOOD SCREWS. FLANGE FRAME I FIN FRAME
9)EQUAL LITE SHOWN.ANCHOR QUANTITY AND SPACING APPLIES TO I
ORIEL SASH UNITS AS WELL.PRODUCT MAY BE INSTALLED INTO STEELI 53-1/8'MAX.TIP-TO-TIP--
OR ALUMINUM SIMILAR TO THE WOOD INSTALLATION DETAILS.
� 52-1/8'MAX.BUCK
10)PASS-THRU PRODUCT HAS NOT BEEN CERTIFIED FOR WATER TABLE 3:FIN&FLANGE ST --- — ---
9"MAX.
INFILTRATION AND MUST BE LOCATED IN UNEXPOSED AREAS. BuckSlze SashS le Desi Pressure Certification —r /
11)THE 200 SERIES WAS FORMERLY KNOWN AS THE 4000/4001 SERIES. Width [Height (+ Sf (-)psf Numbers I
52 1/8" 75" Equal Ute 55 55 1913-478,479,
Oriel SS 55 493,494 1_ / MAX.
17+ BUCK
TABLE 1:FLANGE WINDOWS(STANDARD AND PASS-THRU) TABLE 4:FLANGE PASS-THRU WINDOW MAX. 52" I
Anchorrype a els MIMENT MAX.
Buck Size Desi n Pressure Certification T TIP-TO-
WOW(SouthBmPine) 7716' 1S/8' Width Height + sf (-)psf Numbers I � TIP
r10 Steel SMS 1 t (18 GA) 52-1/8" 51-1/2' 65 .65 190-1002
- Aluminun•808.'rT6-—3/6= —1/8"-
8-1/2-MAX-
1/IT -- -- - -
1/4'Masory Canaete 1' 1-/8' FLANGE FRAME
Anchor Hd10W CMU 2-1/2" 14M. PASS-THRU WINDOW
NOTE FOR ALL METAL SUBSTRATES.SCREW ENBEDMENrSHALL BE MIN 3 THREADS
BEYOND INSIDE FACE OF MATERIAL
.1``- ;1,:.: l..ij/A.•'!, o—w eromco Ar® !
TABLE 2:FIN WINDOWS(STANDARD WINDOW) •� ` `�� J.ROSOWSKI 08/08/11 ALUMINUM 606376 •�°��.ar !
Min.Edge Min. . arr A70aimt�®e
Anchor Type Substrate Dist. Embedment
5-x.135'
ooss'c t
Roofing Nall Nnll Wood(Southern Pine) 31-7116'
i12 Panheea G-( 1/- 107OTECHNOL
SMS Wood(Southern Fine) 811S 1.Y8• -•.:1 'SU! 3x275 T� '
rtormssr»ed �;;. ':_o�;v'::;,•;;�`' CEaT.oFAUTH.:2929s NG INST.,STD.MEETING RAIL
Wood(Southern Pine) 7/16' 1-/8' y,�,yr ars
Screw - A.Lynn Myer,P.E.
P.E.858706 SH-200&20OPT S 1 of 3 1032411JR
r'
INSTALLATION WITH FLANGEFRAME
yy�_tt11 S TRAIE �j EXTERIOR
SU
SU RA � l
1X
SHIM WOOD
WOOD
SHIM /
EDGE
NO DISTANCE
ANCHORS
REQUIRED NO 1_ SHIM
EXTERIOR ANCHORS EMBEDMENT-
REQUIRED RE -{-- —i
QUIRED EXTERIOR
I
FLANGE FRAME,
JAMB INSTALLATION
FLANGE FRAME, (DIRECTLY TO SUBSTRATE)
HEAD INSTALLATION FLANGE FRAME,
(DIRECTLY TO SUBSTRATE) HEAD INSTALLATION -
(USING 1X BUCKSTRIP)
I'U TRgTE DI
EXTERIOR
EXTERIOR
EXTERIOR
EXTERIOR
i
EDGE f
NO DISTANCE �1
ANCHORS ANC ORS 1X
REQUIRED REQ RED SHIM
EMBEDMENT WOOD
MB IN ON `
/
SHIM � KSTR
BST TE_ SHIM (US BUCIP)
1X_
WOOD \•�----- -�--- - fj - '<---- -
FLANGE FRAME, ,^,."" 6 (O:(S.•:
PASS-THRU WINDOW
SU �� SILL INSTALLATION _ ;.C;�G=�•'•,�;�; i
(DIRECTLYTOSUBSTRATE
)
FLANGE FRAME. BS i °iM1a os ��' rbenTry+manorav,�
SILL INSTALLATION _ ..__ J J.ROSOWSKI 08108/11 ALUMINUM6063-TO
xoRmmtrwm:w�srluxa�nas
(DIRECTLY TO SUBSTRATE) FLANGE FRAME. °" F mnaenwn¢�a�mou�x
urlav�rnmrnexsnsr
INSTALLATION NOTES: SILL INSTALLATION reamxa/snamm •
(USING 1X BUCKSTRIP)
1)SEE SHEET 1 FOR ANCHORAGE,SUBSTRATE AND SPACING REQUIREMENTS. 1070 TECHNOLOGY DRNE
2)GLASS SHOWN AS EXAMPLE.MAY VARY BY SERIES AND DESIGN PRESSURE REQUIREMENTS. NOKOMIS•FL 34275
3)FOR SMOOTH SASH OPERATION,THE ANCHORS MUST BE FLATHEADS. FLCERT.OFAUTH..'m96 SINGLE HUNG INST.,STD.MEETING RAIL i
4)MAX.SHIM THICKNESS TO BE 1W. A.Lynn Milia,P.E. !�