Loading...
HomeMy WebLinkAboutProduct Approval (2) I kqsqqkb0PARTMW OF ® . ++ r:.. , SCIS Home I Log In User Registration Hot Topic Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links I Search db' or R E'C"i 1°:' D JUN 2 '9 U17 Product Approval ,, USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail • a FL# FL15213-112 Application Type Revision Code Version 2014 Application Status Approved Comments Archived ;_ Product Manufacturer Plastpro Inc. /Nanya Plastics Corp. Address/Phone/Email 5200 W CENTURY BLVD. LOS ANGELES, CA 90045 (440) 969-9773 Ext 16 rickw@rwbidgconsultants.com Authorized Signature Vivian Wright rickw@rwbidgconsultants.com Technical Representative Scott Johnson Address/Phone/Email 5200 W Century Blvd. Los Angeles, CA 90045 (440)969-9773 Ext 18 scotLjohnson@plastproinc.com Quality Assurance Representative Ron O'Connell Address/Phone/Email 5200 W Century Blvd. Los Angeles, CA 90045 (440) 969-9773 Ext 16 ronoconnell@plastpro.com Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ldJ Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F. Schmidt, P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan J. King, P.E. i✓1 Validation Checklist- Hardcopy Received Certificate of Independence FL15213 R2 COI CERTIFICATE of INDEPENDENCE.pdf Referenced Standard and Year(of Standard) Standard Year 101/I.S.2 1997 101/I.S.2/NAFS 2002 AAMA/W DMA/CSA101/I.S.2/A440 2005 ASTM E1866 2002 ASTM E1996 2002 ASTM E330 2002 TAS 201, 202, 203 1994 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/28/2015 Date Validated 04/29/2015 Date Pending FBC Approval 05/07/2015 Date Approved 06/23/2015 Summary of Products Go to Page Page 1/2 Model,Number or Name Des ription 1521 . a. Smooth/Wood Grain/White Wood 6'8" mpag�t' Opaque Fiberglass Single Door- Grain/Rustic/Mahogany Series Ins ing/Od§wing(X-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R2 II Inst 15213.1.odf P Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.1 for Design Pressure Ratings,any FL15213 R2 AE Eval 15213.1.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.2 b. Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door with Sidelite Grain/Rustic/Mahogany Series utilizing "Snap Frame"Glazing-Inswing/Outswing (OX or XO Fiberglass Door -Configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15213 R2 II Inst 15213.2.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.2 for Design Pressure Ratings, any FL15213 R2 AE Eval 15213.2.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.3 c. Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door with Sidelites Grain/Rustic/Mahogany Series utilizing "Snap Frame"Glazing-Inswing/Outswing (OXO- Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R2 II Inst 15213.3.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.3 for Design Pressure Ratings, any FL15213 R2 AE Eval 15213.3.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.4 d. Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door with Sidelite Grain/Rustic/Mahogany Series utilizing "Lip Lite"Glazing -Inswing/Outswing (OX or XO- Fiberglass Door Configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R2 II Inst 15213.4.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.4 for Design Pressure Ratings, any FL15213 R2 AE Eval 15213.4.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.5 e. Smooth/Wood Grain/White Wood 68"Impact" Opaque Fiberglass Single Door with Sidelites Grain/Rustic/Mahogany Series utilizing "Lip Lite"Glazing-Inswing/Outswing (OXO- Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R2 II Inst 15213.5.odf plastpro �� �• •• ••°��� 5200 W. CENTURY BLVD. ''�•: Z �•'o= 0 c,) LOS ANGELES CA 90045 37.50"MAX.O.A. •.........• �� >>M m FRAME WIDTH i��/I4,111 p„����` o e°a z° l`' 0N •;: �v x01 Smooth/ Wood Grain / White Wood Grain to 9 m W Rustic/Mahogany a m a a Series Fiberglass Door . . E oZ INSWING/OUTSWING 'IMPACT" " Z w Z 3: S2�Zo y ? 0 o wo Sr ZO 2� CJ OVI �W 2 = C J U " GENERAL NOTES ILLJJ(a M Q�2 J v UO 1. This product has been evaluated and is in compliance with the 5th Edition o o ^ o o w (2014)Florida Building Code(FBC)structural requirements excluding the"High 0 a a Velocity Hurricane Zone"(HVHZ). a a s 2. Product anchors shall be as listed and spaced as shown on details.Anchor $ E embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind bome debris protection this product 3 complies with Section 1609.1.2 of the FBC and does not require an impact N resistant covering.This product meets missile level"D"and includes Wind Zone 4 0 U as defined in ASTM E1996 and Section 1609.1.2.2 of the FBC. 0 4. For 2x stud framing construction,anchoring of these units shall be the some as that shown for 2x buck masonry construction. Q a 5. Site conditions that deviate from the details of this drawing require further 0. Z engineering analysis by a licensed engineer or registered architect. w S N o TABLE OF CONTENTS " 'm LF SNEETA DESCRIPTION ^z nD OVERALL ESSU : a a 1 Typical elevation,design pressures,&general notes DESIGN PRRE(PSE): Dare 02116112 ? 2 Door panel details SWING. FRAME n 3 Hor¢antalcrosssections DIMENSION POSITIVE NEGATIVE'; s N.T.S. d DWG.BY: JK W S 4 Vertical cross sections INSWING 37.50"x82.00" +65.0 -70.0 CHK.BY: LFS 3 a 5 Buck and frame anchoring-2X buck masonry construction d DRAWING NO.: 6 Frame anchoring-1X buck masonry construction N OUTSWING 37.50"x 80.37" +65.0 -65.0 FL-15213.1 7 B11 of materials&components SNEEr_L of 7 ro u R:\Gients\Plastpro,Inc PERMANENT\Florida Product Approvals\FL-15233\C-Drawings\Current\FL-15213.1-.8.dwg,31 m— m Z d Die W N OQ= w N D «y a ^ e. j ro H 4 O N `may °< ° z w c ww �= m 0 0 m Z N AZ M �O M 0 x y r Q Q C n. N i(1 Y' w ... O. O. C W �Q H T O 0 M A 0 W W WAnt N Tn Q x y A W ;U m O p M—D o A-+ w AA v A tJ a0= o�o a� (O O�•y V p-�r O. 5 m OA W to N W tr ``tttll ll.11/�� / No.43409 Yz r-.r•°• T $ x a Q PRODUCT: Documents Propomd p c22i [g t^ Lyndon F. Schmidt 'i/q••••• ORIO�`.✓•G,``�� IW I N PLASTPRO INC. P.E. No. 43409 ///�S�O�� \`\� T N o Z\ FIBERGLASS DOOR //Illlilttt,t� r- --1 01 PART OR ASSEMBLY: /� BUILDING CONSULTANTS, INC. IV W N (n\ 1 04 22/15 UPDATE 70 5TH ED. (2014) FT3C UK HORIZONTAL CROSS SECTIONS J l� P•O. Box 230, Valrico, FL 33595 ry NO DATE BY Phone No.- 813.659.9197 REVISIONS I FSPE CA No. 9813 ®2012 R.W.BUILDING CONSULTANTS INC. R1Cllents\Plasfpm,Inc PERMANENT\Florida Product ApprowLAFL-15213W-Drawings\Cunent\FL-152131-.8.dwg,41 X xx Ch ' .. m m ? A co 0T A 00� a'e ° ° c a m� O�f7 mn 1`0n e:Q � O N o�„ .. Z �N to � 0 tT °.. Z Pvv .a O• Q O• P °. T I0 A a4 N a. . P° N m 0.i5' o ' P ' CSINK (TYP.) 1-1/4"MIN. EMB.(TYP.) a A N y O v m G iL7 N < o �A A o a x r M cn .y Cr tq n 0 ly In O Z m a o y m n o p � Z P v Z o FN > ca N ne A 1-1/4"MIN. EMB. ```11µ111111TFE�'i �. F•sCHtilip ��. No.43409 e/.z hrr9'0 o s PRODUCT: Document.ftp—d B"' ; z x m Lyndon F. Schmidt �s••. OFiSD�:�•��`��� PIASTPRO INC. P.E. No. 43409 o Z\ FIBERGLASS DOOR �n �//111j11t111� PART OR ASSEMBLY: �K�/,,'II//BUILDING CONSULTANTS, INC. Iv j in\[NO 04 22 15 UPDATE TO 5TH ED. (2074) Fi3C JK VERTICAL CROSS SECTIONS d 1�VD P•0. Box 230, Valrico, FL 33595 ro DATE BY Phone No.: 813.659.9197 REVISIONS I FBPE C.A. No. 9813 5 2012 R.W.OWL-No CONSULTANT INC. d.. �:ZZlt. yy t. d ro 0. �� n N'3 I 'W'• y� F cNro N a I l*P1\\`\` ti N m Z ° 30 .0 � v i o TYP.HEAD$ _ � �� g N g 9 O L a JAMBS a m a a 1X BUCK E m`Z c vi FRAME U O t!q . D z0 00 W X0 J �0, MASONRY tii Eii�w woo OPENING 4, Z U m O �I v o O U at O O] a � X tH 6.k4U E a N O z y Z HINGEJAMB FRAME ANCHORING STRIKE JAMB w o Masonry 1 X buck construction m G CONCRETE ANCHOR NOTES: 1.Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to mortarjoints. 2 Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to a a maintain the min.edge distance to modarjoints,additional concrete anchors e a may be required to ensure the"MAX.ON CENTER"�mension are not exceeded. 21 z 3 a3 Concrete anchor table 32 Y6 33 'w z s pry„CNO.�t ANCHOR i, ,Mlttl.,; MIN EtfARANCE MIN CIEARANC�; 31 N c 70(l7ASONRY TO ADJACENT � \o � o TYPH SIZE E'MB�'DMENT .,:EDGE ANCHOR m m ITW ® 1/4' 1.1/4” 2" 4" 8 27 33 z a �o a a TAPCON —02116112 i ULTRACONO 1/4' 1-1/4"ELCO1" 4" SCALE: N.T.S. ° o TAPCON® 3/16" 1.1/4" 7. BWG.er: JK in WOODSCREWINSTALViTIONNOTES: HINGEJAMB STRIKE PLATE DETAIL CNH.BY: LFS 3 DRAWNG NO.: s a minimum 5/B edge d stance,1"end distance,&1"o.c.spacing of FL-15213.1 N wood screws od. ° uy SHEET 6 OF 7