Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQw... t �!-r•j;' r,, vi* `.�f LSF � ��I� -r s, 1 . BCLS Home i Log In User Registration s Hot Topics I Submit Surcharge Stats&FacLs ', Publications FBC Staff BC15 Site Map Links Search s Fbl ida f=; °'<:d, Product Approval USER:Public User 'Opr ... . ..l��rfil�� •. . Product Aoproval Menu>Product or Application Search>Application List>Appflotbn Detal FL# FL7006-119 1 Application Type Revision . Code Version 2014 Application Status Approved .... *Approved by DBPR:'APproval§by DBPR shall be reviewed and ratified by the POC and/or the Commissl n if necessary. Comments Archived i Product ManufacturerIKO Industries,Ltd .Q, Address/Phone/Email. 40 Hansen Road South. Brampton,NON-US L6W 3H4 " (708)496-2800 Ext200 rmetzOO1@tampabay.rr.com Authorized Signature Robert Metz rmetzOO1@tampabay.rr.com Technical Representative Bob Metz Address/Phone/Email: REMCO of Pinellas 456 Avila Circle NE Saint Petersburg, FL 33703 '(727)776-5261 rmetz001@tampabay.rr.com Quality Assurance Representative Don Shaw Address/Phone/Email IKO Industries LTD 120 Hay Rd. Wilmington,DE 19808 (717)579-6706 don.shaw@iko.com Category Roofing Subcategory Asphalt Shingles Compliance Method. Certification Mark or.Listing Certification Agency FM Approvals-CER Validated By Locke Bowden Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year ASTM D3161 modified to.110 mph 2009 ASTM D3462 2009 ASTM D7158 Class H 2008 ASTM E108 2007 . 1 of 3 3/14/2017 5:57 PM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEUXQw... Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 06/28/2015 Date Validated 06/30/2015 Date Pending FBC Approval Date Approved 07/06/2015 Summary of Products FL# ber or Name Description 7006.1 Cambridge, ambridge HD.and CRC Laminated architecturi fiberglass asphalt shingle iltniore manufactured at IKd'sl Kankakee, IL; Hawkesbury,Ont.; Wilmington,DE; Sylacauga,AL and Toronto;Ont.plants Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL7006 R9 C CAC FM Letter-ASTM d3161 letter Approved for use outside HVHZ:.Yes 4-15-2015•.pdf Impact Resistant::N/A FL7006 R9 C CAC FIM Letter-ASTM d3462 letter-5 6 Design Pressure:'N/A 15.1)df .Other: FL7006 R9 C CAC FM Letter--ASTM E 108.letter- 5 3.. 15 .pdf Quality Assurance Contract Expiration.Date 12/31/2020 Installation Instructions FL7006 R9 1I IKO-133-02-01 Letter-Installation Instructions for FBC FL7006.pdf Verified By: DucT'Ng'uyen 65034 Created by Ind epend'entThird Party: No Evaluation Repos'( Created by Indepertndent Third Party: i 7006.2 Hip and Ridge 12 Cap fiberglass This is a 12"x 12"'fiberglass asphalt shingle used to cover shingles the hip and/or ridge of an asphalt shingle roof system manufactured in Torohto, Ont.and Brampton;Ontario Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL7006 R9 C CAC 'I M Letter-ASTM d3161 letter- Approved for use outside HVHZ:Yes 4-15-2015 .pdf Impact Resistant:N/A FL7006 R9 C CAC FM Letter-ASTM d3462 letter-5 6 Design Pressure: N/A 15.pdf Other: FL7006 R9 C CAC FM Letter-ASTM E 108 letter- 53 15 .pdf Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions - FL7006 R9 1I Hio and Ridge Cap Shingle Installation Instructions.pdf FL7006 R9 II• IKO-133-02-01 Letter-Installation Instructions for FBC FL7006,pdf Verified By: Duc T Nguyen PE 65034 . Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 7,006.3 Leading Edge Plus Asphalt Shingle One piece fibergla;ss'asphalt shingle used as a starter strip at Starter Strip the bottom of a roof system manufactured in Brampton and Hawkesbury;Onta,riol plants Limits of Use Certification,Agency Certificate Approved for use in HVHZ:Yes 'FL7006 R9 C CAC'IFM Letter-ASTM d3161 letter- Approved for use outside HVHZ:Yes 4-15-2015 .pdf Impact Resistant: N/A FL7006 R9 C CAC'FM Letter-ASTM d3462 letter-5 6 Design Pressure: N/A 15.odf Other: FL7006 R9 C CAC I FM Letter-ASTM E 108 letter- 5 3 15 .pdf 2 of 3 3/14/2017 5:57 PM I KO Installation Instructions for Asphalt Shingles Page 3 of 5 IKO Laminated Shingles Application Instructions (ASTM D3161, Class F—.Cambridge,:Cambridge HD,,and CRC Biltmore AR) NOTE: THESE INSTRUCTIONS SHALL. BE USED IN CONJUCTION Wlj H IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT,THESE INSTRUCTIONS wILL:GOVERN... ROOF DECK: Solidly sheathed and fastened deck conforming to 2014 FBC. UNDERLAYMENT:Applied in accordance with building code requirements.For areas where the roof slope is less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code requirements, the first sheet overlapping the eave protection by 19",followed by full 36"widths overlapping each preceding course by 19"or other Approved underlayments in accordance jwith the qualified application ..... instructions. For areas where the roof slope is 4'.' per foot or greater,.cover the.deck with.one ply of underla ment laid parallel to the eaves,'with 2"horizontal la s and 4"end laps. Apply metal drip edges on to y p P P � PP Y . P 9 P of any underlay along rake edges and directly to the deck along eaves:in accordance with building code requirements. , NAILING: Use galvanized(zinc coated)roofing nails, 11 or 12 gauge,with at least 3/8"diameter heads,long enough to penetrate through plywood or 3/4"into board&- Use 4 nails per shingle placed in the nail line 7-3/8" below the top edge, approx. 1"and 13" in from each end.. Drive nails straight so that nail head is flush with, but not cutting into shingle surface. NAILING ON STEEP SLOPES:For steep slopes of 21"per foot(60°)or more, use 6 nails pershingle placed as shown below. Ensure that no nail is within 2"of a joint/cutout of the underlying shingle. Seal down each shingle at time of application with three 1"diameter(approx.size and thicknesslof a quarter)spots of asphalt plastic cement placed.under the shingle 2" above the,bottom edge and equally Ispaced along the.shingle. ..... .Apply plastic cement in moderation since excessive amounts may'cause blistering. CAUTION:Shingles should seal to the underlying course when the factory.applied asphalt sealant'•is!sufficiently warmed by the heat of direct sunlight. EXPOSURE: Installed shingles shall have a maximum average exposure of 5-7/8". NAILING—STEEP SLOPES APPLICATION Use six nails as shown. 7 3/8" NAIL LINE 6 3/Wt rl"r— . ' NAILS CEMENT PROPER APPLICATION:REQUIRES THAT THE NAILS:PENETRATE BOTH THE OVERLAY AND UNDERLAY PORTIONS OF THE SHINGLE PRI Construction Materials Technologies,L LC.6412 Badger Drive Tampa,FL 33610 Tel:813-621-5777 Fax:813-621-5840 e-mail;materlaist6sfing@pdcmt.com Website:http:lMiww.pricmLcom IKO Installation Instructions for Asphalt Shingles Page 5 of 5 IKO Leading Edge Plus Application Instructions (ASTM D3161, Class F—IKO Leading Edge Plus) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS.AND THE APPLICABLE CODE.'.IN THE EVENT THE INSTRUCTION CONFLICT,THESE INSTRUCTIONS WILL GOVERN.: 1. Apply any underlayment, eave protection, valley flashings, or drip edges to roof deck as required. 2. Each 39 3/8"x 131/4"(1000 mm x 336 mm)IKO Leading Edge Plus strip is perforated lengthwisefor separation into two(2)shingles.Take one IKO.Leading Edge Plus strip,and fold flat at perforation to separate. 3. Take one of the separated shingles 39 3/8"x 6 5/8"(1000 Mm x 168 mm,)and remove approximately 20"(500 mm). Install this shingle.on the lower left corner of the roof de'ck�, granule side up,with the. factory installed sealant adjacent to the eaves.The shingle should overhang the rake edge and eaves by a nominal 1/4"(6 mm)minimum..Fasten the shingle to the roof deck w i�h nails located 3"to 4"{75 mm to 100:mm)from the eave-edge and 1"(25 mm) in from each end. - 4. Take the leftover 20"(500 mm)piece shingle. Rotate the piece and align it vertically up the rake edge with the factory installed sealant adjacent to the outer edge of the roof.The shingle should overhang 11 the rake edge by a nominal 1/4"(6 mm)minimum. Fasten the shingle to the roof deck with fasteners located 3"to 4"(75 mm to 100 mm),from the rake edge and-1" (25m )1in from each end. 5. Repeat Steps 3—.4.for the rightlower corner of the roof deck.. NAILING:-Use galvanized (zinc.coated) roofing nails, 11:or 12 gauge,with at least 3/8"(9 mm)diameter heads, long enough to penetrate through plywood or 3/4"(20 mm) into boards. Use 4 nails.per shingle placed 3"to 4" (75 mm to 100 mm)from ., the eave edge and approximately 1 and 13"(25 mm and 330 mm)in from each end.: 1 6. Apply full-length IKO Leading Edge Plus shingles to the remaining eave edges of the roof deck.Install the shingles granule side.up with the factory applied sealant adjacent to the eaves. The.shingles should overhang the rake edge and eaves by a nominal 1/4"(6.mm)minimum. Fasten the shingles to the roof deck with nails located 3"to 4"(75 mm to 100 mm)from the eave edge,4 nails per shingle. 7. .Apply roof shingles as per the instructions printed on each product's package. Make certain the first course of field shingle lies flush with the edges of the fastened-IKO Leading Edge Plus. In this way, the sealant on the IKO Leading Edge Plus shingles will adhere to the first-course field shingles and help keep them from lifting in high winds. PRI Construction Materials Technologies,LLC.6412 Badger Drive Tampa,FL 33610 Tel:813-621-5777 Fax:813-621-5840 e-mail;materialslesting@pricmtcom WebSite:http:/MWw.pdcmt.com CONSTRUCTION MATE RIALS TE:CHNOLOG:IES . March 30, 2015. IKO:Industries, Ltd 120 Hay Rd. Wilmington, DE 19809 Re: FBC FL7006 Sir(s), PRI Construction Materials Technologies has completed a technical review and attached sealed shingle instructions in compliance the 2014 Florida Building-Code. . Ir This review was completed based on the receipt of following evidence from IKO Industries, Ltd: 1) IKO Shingle Application Instructions".3-Tab Shingles (EN-3Tab Appins_8AGXEFS-2012-11_reformatted 2013-02-rev07/13=Florida). 2) .IKO Laminated Shingles Application Instructions (EN-Laminated Appins_8TTEFS-2012-04 .reformatted 2013=02-rev07/13-Florida) 3) IKO Hip and Ridge 12.Application Instructions (EN-HipandRidge 12_3HRTri-2013-08_reformatted 2013-08) 4) IKO Leading Edge Plus Shingle Application lnstructio'hs (EN-3LEP -Tri-2012-06_reformatted:2013-03) 5) ASTM D3161 Test Report(FM Approvals Project No. 3040947) The attached instructions should be used in conjunction with the published manufacturer's application instructions and applicable code. In the event the instructions conflict; these instructions shall govern . Statement of Independence:PRI Construction Materials Technologies and/or Duc T. Nguyen, FL P.E.do riot have nor plan to acquire a financial interest in any company manufacturing or distributing products for which the test reports are issued. Signed: / Signed: Brad Grtybo skiDuc Managing Director Florida Re ered Professional Engineer LE.Number:65034 Date: April 30,2015 Date: April 30, 2015 Attachments: A) IKO Shingle Application Instructions-3=Tab B)'IKO Laminated Shingles Application Instructions C) IKO Hip and Ridge 12,Application Instructions D.) IKO Leading Edge Plus Application Instructions IKO-133-02-01 PRI Construction Materials Technologies,LLC.6412 Badger Drive Tampa,FL 33610 Tel:813-621-5777 Fax:813-621-5840 a-mail:materialstIes6ng@pricmt.com WebSite:hftp:/Iwww.pricmtcom