HomeMy WebLinkAboutWind Load Calculation Property Information Building Information Owner: Richard Rivera Wind Zone: 160 MPH. Address: 315 Olive Ave Exposure Category: B Port St Lucie,F134952 Minimum Building Dimension: 24 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(Dsf) Pressure(psf) -4�}t 74 37 WE I t 74 59I1376 I nt 28 24 7 Int 72 49 8 Int 35 36 .5 -35.2 9 Int 72 80 7 29.6 -32.3 10 Int 34 36 7 32.5 -35.2 11 Int 35 36 7 32.5 -35.2 Prepared in accordance H,itlt:ASCE 7-10,Chapter 30. Hrind Loads-Components and Cladding.5th Edition(2014)Florida Building Code, Page 1 of 1