HomeMy WebLinkAboutBuilding Permit Application ALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED //�� 1'� ^ �
Date: �' �� Permit Number: I 1 n !_ (y'�
Building Permit Application JUL ; 3 f2oll
Planning and Development Services
Building and Code Regulation Division
Sk.<
Lucie FL
Phone:
2300 Virginia Avenue,Fort Pierce FL 34982
Phone: (772)462-1553 Fax: (772)462-1578Commercial R sidential x
PERMIT APPLICATION FOR: Window/door !7
PROPOSED IMPROVEIVIENTL� I' NJ
Address: 10680 S.Ocean Dr.apt.604,Jensen Beach, FL.34957
Legal Description: '71S6 Lre-
Property Tax ID#: — Lot No.
Site Plan Name: Block No.
Project Name:
Setbacks Frontx "I"WSBack: Right Side: Left Side:
DETAILED,DESCRIPTIONO`F _ F
Remove existing windows and Replace with Insulated Impact windows. Shutters are in place.
ddel g1.55
r(OA 3 I,i;n�pl�iS
CONSTRUCTIO
+ N`INFOR'MATION> _ ` Kfi 5 r
Additional work toe nertormed uncierthis permit—check a appy:
HVAC 0 Gas Tank ❑Gas Piping _Shutters Ft/]Windows/Doors
Electric ❑Plumbing Sprinklers Generator Roof Roof pitch
Total Sq. Ft of Construction: S Ft.of First Floor:
Cost of Construction: Utilities. Sewer Septic Building Height: 12 stories
OWNER LESSEE C CTO`R
O
Nam eJames Pownell Name: Anthony R.Soares
Address:10680 S.Ocean Dr. A0. 60y Company: Florida Glass Solutions, Inc.
City: Jensen Beach State:FL Address: 534 NW Mercantile Pl.Unit#118
Zip Code: 34957 Fax: City: Port St.Lucie State:fl'
Phone No.508-612-4967 Zip Code: 34986 Fax:
E-Mail:jim@pownell.org Phone No. 772-985-5795
Fill in fee simple Title Holder on next page(if different E-Mail: floridaglasssolutions@gmail.com
from the Owner listed above) State or County License: SCC131151466
If value of construction is$2500 or more,a RECORDED Notice of Commencement is required.
DESIGNER/ENGINEER: _Not Applicable MORTGAGE COMPANY: _Not Applicable
Name: Name:
Address: Address:
City: State: City: State:
Zip: Phone Zip: _ Phone:
FEE SIMPLE TITLE HOLDER: _Not Applicable BONDING COMPANY: Not Applicable
Name: Name:
Address: Address:
City: city:
Zip: Phone: Zip:. Phone:
OWNER/CONTRACTOR AFFIDVIT:Application is hereby made to obtain a permit to do the work and installation as indicated.
I certify that no work or installation has commenced prior to the'issuance of a permit.
St.Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules,bylaws or and covenants that may restrict or prohibit such
structure.Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit,I do hereby agree that I will,in all respects,perform the work
in accordance with the approved plans,the Florida Building Codes and St.Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review:room additions,
accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory uses to another non-residential use
WARNING TO OWNER:Your failure to Record a Notice of Commencement'may result in your paying twice for
improvements to your property.A Notice of Commencement must be recorded and posted on the jobsite
before the first inspection. If you intend to obtain financing,consult with lender or an attorney before
commencing work or recording our Notice of Commencement.
Signature of Owner/Lessee/Contractor as Agent for Owner Signature of Contractor/License Holder
STATE OF FLORIDAL� CL� STATE OF COUNTY OF FLORIDA.
COUNTY OF
Theftoing Inst me t 'as aq cnowled a efore me The forgoing instr ent was no ledg efore me
this ay of 2by this ay of 20 My
VVIJ
l
(AamE�of person acknowled ing) (Nam of person acknowledgi g)
(Signature of Notdry Public-State of FI rids) (Signature of Nota Public-State of Florida)
Personally Known OR Produced Identification Personally,Kn,,a ikli'P'� CSR ' tft?e d�ld nt'fcat'on
Type of Iden4t5)ificat+ Type of Iden�i c ��No p bl cLA M HUFF
Produced 7 _aaatPnY�f/ Produced N+ �--C State of Florida
Notary Public-St eUol Florida f �4�FFlOp� MY Comm.Expires May rr 4730
(( •- R """"� Bonded thr
�n Commission#�jSg� Commisslo _ ou NationalNo�
Commissiori;No:*. Mao t'a Wn
YAssn. "
i '?,UFFlnpo'a YCOMM.Expires May 27,2019
F --
"""" Bonded throu h ati
REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE
COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW
DATE
RECEIVED
DATE
COMPLETED
ev.
All APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: Permit Number:
Bui ing ermit App �atio
Planning and De v opment Services /
Building and Code R ulation Division
2300 Virginia Avenue, Pierce FL 34982 `
Phone: (772)462-155 ax: (772)462-1578 Commercial / esidential
i
PERMIT APPLICATIO OR:
Address:
Legal Description:
Property Tax ID#: LLot No.
Site Plan Name: Block No.
Project Name:
Setbacks Front Back: Ri ' e: Lefte:
Adafflonal work to be pe or ea ut is permit–check a at appy:
_Mechanical _Gas- e _Gas Piping _Shutt s Wind s%Doors
Electric _Plu i _Sprinklers _Generato Roof Pitch
Total Sq. Ft of-Construction: Sq. Ft.of First Floor: -
Cost of Construction:$ ilities: _Sewer —Se is ilding Height:
Name Name:
Address: \t Company.
City: State:_ ,Address
Zip Code: rTritle
Fax: City: State:
Phone No. Zip Code: Fax:
E-Mail: Phone No
Fill in fee si r onnext page(if different E-Mail
from the Owner listed above) State or County License
If value of construction is 2500 or more,a RECORDED Notice of Commencement is required.
PAUL WELCH INC.
Mechanical * Electrical * Civil Engineering
1984 S.W. Biltmore St. Suite#114
Port Saint Lucie, FL'34984
Phone (772)785 - 9888
Email pwelchinc@aol.com JUL a 2 ;'
PEF,:1?I Ti �G
July 12,2017 OPY uril -Re: Window Re lacementP 10680 S. Ocean Dr.
57
i:
Jensen Beach, FL 34957
To Whom It May Concern:
Our office has calculated the required design pressure in accordance with ASCE 7-10 for
a replacement of the windows at the above referenced address.
Wind speed: V,it: 165mph,Via: 124 mph
Exposure: D
Enclosure Type: Enclosed
Window Size: Per Attached Schedule(same size as windows removed).
Location: Zone 5 (Worst Case)
Required Design Pressure(Zone 5): +48.7/-65.1 PSF
Windows to be installed shall be equal to, or exceed the required design pressures as
listed above. All installations shall be in accordance with FBC 2014 and manufacturer's
installation instructions.
Thank you for your attention to this matter.
Submitted by:
PAUL WELCH C.
� f
Paul Welch,P.E. 1
Reg.No 29945
Attached: Product-Approval Affid.
Area of Work Plan
Planning & Development Services Department
t or, �' ' Building & Regulations Division
i> Product Review Affidavit
Building Permit# Owners Name d W lv t L L Applicant:
40 to°oo S� DG?AN Drz �i!(p04 ��NS�N .
Product Opening Design Product Rated Manufacturer Model Number Product Approval Glass Method of Attachment
Pressures Desion Pressure Number Type
Windows +4a,� -(05, 1 +l_$V �,AWSanI 5H "+ 00 Ate-10o3-01 �' .�T, 1/4"x1 K�N,fsMggh TA.PGo�+ T
4el Ib S/ Orli tlr pigov, PP.
Mullions * 4 0 (X4,olo Cx foFL NaAb222 13 N�A 5�1�0" pt'�NL��N. 'T��A bT�o� w�
Fixed Glass
Block Glass
Skylights
Sildind Glass Doors
Swing Type Doors
French Doors
Garage Doors
Hurricane Protection
Roof Ventilation '
Roofing Material
I have reviewed the above components or cladding and I have approved their use in t �s true ture. These products provide adequate resistance to the
wind loads and forces specified by current code provisions.
L WELCH P.E.
Name: PAUL Signature:
Design Prof:. PAUL WELCH P.E.i Cert.No. 29945 Dater,
L
I am only replacing windows
in yellow
kitchen kitchen get(?�7x63
bedroom get 531/8"x 63
balcony front entrance
living room ••.-- sliding glass doors
bedroom bathroom bedroom
bathroom
rn
�CDC::
rnrZC �rr.. ntS...
r �„<. AREA OF WORK PLAN
zrm-0:0 -'
00 Moo
ni
c(o.-U
ami MO
Window Replacement !
a�
10680 S. Ocean Dr.
Jensen Beach, FL 34957
ON,
� n;
7___a�N
J U L
MIAM I•ME P E I fl, 7 1'`'9MUM-DADE COUNTY
St LUCiza ""I - -F1,111111a — "" PRODUICTCONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION • r V4§A 6 1
�)315- - XrFJ8 )35-2599
NOTICE OF ACCEPTANCE (N00 ov/econom
% L
Lawson Industries,Inc. d L4 Ll MY
8501 NW 90 Street
Medley,FL 33166
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section(In Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER
reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code,including the High Velocity Hurricane Zone.-
DESCRIPTION: Clipped Extruded Aluminum Tube Mullion w/and w/o Steel Reinforcement—L.M.I.
APPROVAL DOCUMENT: Drawing No. LAW-ML-1001, titled
d "Aluminum Tube Mullions" sheets I
through 10 of 10, dated 04/27/10 with revision C dated 02/16/17, prepared by manufacturer, signed and
sealed by Thomas J. Sotos,P.E., bearing the Miami-Dade County Product Control Revision stamp with the
Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section.
MISSILE IMPACT RATING:Large and Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the manufacturees name or logo, city, state,
series, and following statement- "Miami-Dade County Product Control Approved", unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change.in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed,then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises and renews NOA No. 14-0908.08 and consists of this page I and evidence pages E-1,
E-2 and E-3,as well as approval document mentioned above.
The submitted documentation was reviewed by Manuel Perez,P.E.
NOA No. 17-0222.13
MIAMI-RADE COUNTY Expiration Date: May 30,2018
4,19 Approval Date: April 13,2017
Page 1
Lawson Industries,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
A. DRAWINGS
1. Manufacturer's die drawings and sections.
(Submitted under NOA Is No. 02-0501.05 and 95-1212.09)
2. Drawing No.LAW-ML-1001,titled"Aluminum Tube Mullions", sheets 1 through 10
of 10, dated 04/27/10,with revision C dated 02/16/17,prepared by manufacturer,
signed and sealed by Thomas J. Sotos,P.E.
B. TESTS
1. Tensile Test report on 0.10"thick wall aluminum tube mullion,prepared by Hurricane
Engineering&Testing,Inc.,Test Report No.HETI-02-T071, dated 09/16/02,tested
per ASTM E8, signed and sealed by Rafael E. Droz-Seda,P.E.
(Submitted under NOA No. 02-0501.05)
2. Test report on: 1)Uniform Static Air Pressure Test,Loading per FBC,TAS 202-94
along with marked-up drawings and installation diagram of 120" span aluminum tube
mullions with C4 x 4.5 steel channel reinforcement, prepared by Hurricane
Engineering & Testing, Inc., Test Report No. HETI 02-1714, dated 08/27/02, signed
and sealed by Rafael E. Droz-Seda,P.E.
(Submitted under NDA No. 02-0501.05)
3. Test reports on: 1)Large Missile Impact Test per FBC, TAS 201-94.
2) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked-up drawings and installation diagram of 120" span aluminum tube
mullion with C4 x 4.5 steel channel reinforcement,prepared by Hurricane Engineering
& Testing, Inc., Test Report No. HETI-02-1716, dated 8/27/02, signed and sealed by
Rafael E.Droz-Seda,P.E.
(Submitted under NDA No. 02-0501.05)
4. Test reports on: 1)Large Missile Impact Test per FBC,TAS 201-94.
2)Cyclic Wind Pressure Loading per FBC,TAS 203-94
along with marked-up drawings and installation diagram of an aluminum sliding glass
door,prepared by Hurricane Engineering&Testing,Inc.,Test Report No.
HETI-02-1718, dated 8/27/02,signed and sealed by Rafael E.Droz-Seda,P.E.
(Submitted under NOA No. 02-0501.05)
5. Test report on: 1)Uniform Static Air Pressure Test,Loading per FBC,TAS 202-94
along with marked-up drawings and installation diagram of an aluminum sliding glass
door,prepared by Hurricane Engineering&Testing,Inc., Test Report No.
HETI-02-1717, dated 08/27/02,signed and sealed by Rafael E.Droz-Seda,P.E.
(Submitted under NOA No. 02-0501.05)
an erez,P.E.
Product Co r Examiner
NOA No.17-0222.13
Expiration Date: May 30,2018
Approval Date: April 13,2017
E-1
Lawson Industries,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
B. TESTS(coN iNuED)
6. Test report on: 1)Uniform Static Air Pressure Test,Loading per FBC,TAS 202-94
along with marked-up drawings and installation diagram of an aluminum sliding glass
door,prepared by Fenestration Testing Laboratory,Inc.,Test Report No.FTL-1376,
dated 01/31/96, signed and sealed by Gilbert Diamond,P.E.
(Submitted under NOA No. 95-1212.09)
7. Test report on: 1)Uniform Static Air Pressure Test,Loading per FBC, TAS 202-94
along with marked-up drawings and installation diagram of two aluminum.horizontal
sliding windows mulled at top with a 90"span mullion and a 45"high fixed window
on top,prepared by Fenestration Testing Laboratory,Inc., Test Report No. FTL-1383,
dated 02/13/96, signed and sealed by Gilbert Diamond,P.E.
(Submitted under NDA No. 95-1212.09)
C. CALCULATIONS
1. Anchor verification calculations and structural analysis,complying with FBC-2010,
prepared by manufacturer,dated 05/17/10 and updated on 01/25/12,prepared, signed
and sealed by Thomas J. Sotos,P.E.
(Submitted under NOA No. 12-0127.07)
D. QUALITY ASSURANCE
1. Miami-Dade Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS
1. Statement letter of conformance,complying with the FBC 51h Edition (2014),dated
February 17,2017,issued, signed and sealed by Thomas J. Sotos,P.E.
2. Statement letter of no financial interest, dated 05/20/12, issued, signed and sealed by
Thomas J. Sotos,P.E.
(Submitted tinder NOA No. 12-012 7.07)
3. Laboratory compliance letter for Test Reports No. HETI-02-1714, HETI 02'1716,
HETI-02-1717, HETI-02-1718, dated 8/27/02 and IRETI-02-T071, dated 09/16/02,
all issued by Hurricane Engineering & Testing, Inc., signed and sealed by Rafael E.
Droz-Selo,P.E.
(Submitted under NOA No. 02-0501.05)
Manuel P.E.
ProductConl, l E miner
NOA No. -0222.13
Expiration Date: May 30,2018
Approval Date: April 13,2017
E-2
Lawson Industries,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
F. STATEMENTS (corrun my
4. Laboratory compliance letter for Test Reports No. FTL-1376, dated 01/31/96, and
FTL-1383, dated 02/13/96, .both issued by Fenestration. Testing Laboratory, Inc.,
signed and sealed by Gilbert Diamond,P.E.
(Submitted under NDA No. 02-0501.05)
5. Letter from manufacturer requesting a 1-year extension to allow time to perform
verification test, dated 04/07/17,signed by Nelson Erazo.
G. OTHERS
1. Notice of Acceptance No. 14-0908.08, issued to Lawson Industries, Inc. for their
Clipped Extruded Aluminum Tube Mullion w/ and w/o Steel Reinforcement
L.M.I.", approved on 11/06/14 and expiring on 05/30/17.
2. One year approval, subjected to successful verification test.
Man rm,P.E.
Product Coro xaminer
NOA .17-0222.13
Expiration Date: May 30,2018
Approval Date: April 13,2017
E-3
e
THESE MULUONS ARE RATED FOR LARGE MISSILE IMPACT N
_ AND CAN BE USED WITH ALL LAWSON'S MIAMI-DADE - q:
ANCHOR/CLIP ANCHOR/CLIP COUNTY APPROVED IMPACT AND NON-IMPACT PRODUCTS. o
GLAZING HORIZONTAL MULLION o 0
PRODUCT _ RECTANGULAR ALUMINUMM TUBE'MULLONS _ h
ANCHOR/CUP HORIZONTAL MULUON GLAZING _ USING ML'J.LION PROPERTIES ONLY n I ,.
yam U
PRODUCT 3 GENERAL NOTES:
THIS PRODUCT HAS BEEN DESIGNED TO COMPLY WITH THE 3�` z
t. �•, 3 4 J '+ REODUIEMFIlS OF THE 20N'RORIOA BIAIDLYG CODE BT!E0T11OM IHCWDRiG ... y
+n HIGH VcLOC17Y HURRICANE ZONE(HVHZ). Z°�'2 q Z - -.
VERTICAL VERTICAL _II - 2.AL C,AZLNG PRODUCTS USED WITH THESE MULLIONS MUST MEET THE N w Z 0 z
MULLION MULUON B APPLICABLE FLORLDA BLDG.CODE REQUIREMENTS LE'WIND LOAD.WATER
INFILTRATION,FORCED ENTRY RESISTANCE.SAFEGIAROS ETC. P
Z li J.MULLIONS ARE APPROVED FOR NPACT AND NON-IMPACT APPLICATIONS
GLAZING GLAZING GLAZINGa 1, GLAZING 3
INCLUDING WINDOWS,DOORS OR COMBINATIONS MAY BE MULLED. I [.1 I
PRODUCT PRODUCT PRODUCT a
4.W000 BUCKS 91'OTHERS,MUST BE N1CJtORc'➢PROPERLY 10 TRANSFER V 7= S
2 w PRODUCT LOADS TO THE STRUCTURE e F z
S.
ANLNORS SIAL BE AS LISTED.SPACED AS SHOWN ON DETAILS.ANCHORS U = 2
EMBEOMENi TO BASE NAIERtAL SH&L BE&POND W DRESSING OR STUCCO. Z EEEE
ANCHOR/CLI 3 6.ANCHORING OR LOADING CONDITIONS NOT SHOWN IN THESE DETAILS ® j x A§
/
ARE NOT PART OF THIS APPROVAL.' . _ a q
7.A'LOAD DURATION INCREASE IN ALLOWABLE STRESS IS USED IN DESIGN OF
WOOD ANCHORS ONLY. T61 6
8.MATERIALS INCLUDING BUT NOT LIMITED TO STEEL ON METAL SCREWS. W 1
Wi W2 , WJ
THAT COME INTO CONTACT WITH OTHER OISSAOAR MATERA LS SHALL MEET J
MULLION SPAN
' MULLION SPAN THE REOUVTEMENfS OF PIE 2014 FLORICA BLAT.CODE-SECTION 2003.6.4. 4 `4
W7 ->- + ,
WIDTH (W) _ . W2 W32
1. FOR MULLIONS WITHOUT REINFORCEMENT REFER TO SHEET
2 OF 10 FOR DETAILS AND NOTES.
ANCHOR/CLIP ANCHOR/CLIP^ - REFER TO.SHEET 3 OF 10 FOR MAX. MULL DESIGN PRESSURE CHARTS
A'^ HORIZONTAL MULLION 2. FOR MULLIONS WITH STEEL_REINFORCEMENT REFER TO SHEET R Viag:
4 OF 10 FOR DETAILS AND NOTES. E
��GLAZING • REFER TO SHEET 5 OF TO FOR MAX. MULL DESIGN PRESSURE CHARTS
VERTICAL PRODUCT :`� 3. FOR CLIP TYPES AND ANCHOR CONDITIONS REFER TO SHEETS 5 d ^
MULLION i `� V/ `• 3� 6, 7, 8, &9 OF 10 FOR DETAILS AND NOTES.
l I +n •REFER TO SHEET 10 OF 10 FOR MAX.ANCHOR DESIGN PRESSURE CHARTS Y
7 3 n g
GLAZING GLAZING o� • �T
PRODUCT PRODUCT wai GLAZING '• GLAZING II • > e
s PRODUCT PRODUCT o z a 5 Yz
a
VERTICAL m
t:J
MUWON
ANCHOR CLIPL /1 11 ....
- o
Wi Wz l z •`AZ
wt WZ - I'kOOULTREYISEU Ey'0 O
Y! MULLION SPAN mmlM1yiyq wNh,ye FN'15u .� TA
' A F lkll� �. o��W N � •�.
12
WIDTH (W) = W1 2WIDTH (W) = wt +Wz
2 pY bcde h
nowt �°'� a O`',p`
TYPICAL MULLION ARRANGEMENTS �'ncea TTnAA F
0
.1690
.129
A62 Isco c
eC, o
3400
1 La05-y a i _ 4.400 .I19 Llk' .129 �n o
I 11 Z
II 3. •+ ya
I 2 X 4 TYPIGL x900 I.T32 2.062
TUB FxwE I 2.000 i W o vl a
?_XX MULLION QIP ULL O' T j .t� g a i •j Z,
6063-T6 I88J I IG2 I(^ I 1400 } .102 I LOW I .156.OTCH �Qm
Z6.000 1--1CG2-i �UBe� 136 ,�IA62� UB ,
\ t O fl u 'E-� 2% 6 7 X 4 1 X 3 1 X'3 1 X 2 1 X 2 2 tri c g
STD.TUBE CUSTOM MULLION CUSTOM MULLION CUSTOM MULLION CU570M MULLION CUSTOM MULLION m m
MULLION 6063-T6 6O63-To 806)-te 6a&i-T6 mNI-16
I Ixx:2.070 ink Ixx: 1.D00 iri. Ixx:0.950 in! In:0.370 in: Ixx:0,330 i,: (J
Sxx: 1.035 ins Sv 0.657 ins Sxx:0.633 ins Sxx:0.370 ins Sxx:0.330 ins y p
(11AN^.E FRAME) (FM FRAME) (FLANGE MA E) (FIN FRAVE) (rWY„E FRAME)
STANDARD TUBJIAR SHAPES P 01)UCTREVISED4
m.WALL.-125'ALL witllAw FhxLla
ALIOY a 6063-% I I�1.00 C 4ing3Cbda N G V
I I .123 Ima W ro G
.?so TYJICAL TI- Z
GLA21R6"PRODUCT 124 1 IAW� I'Jxn Ode ? 6
3z5 Y 13xdefiMmn a
nW 2000
x000 ., at
-�_ � .129
6cx 3n00
ISM MI6 ♦_
1%MULLION CUP x900 ',E R ave
3400 .AW .4 a �
6063-T6
MULLII�J$1;ONT ININ�, 530.TURFMULLION 'jj"T BE Mu1114ti' 71�t
TYPICAL GI AZ1NG PRODUCTS x663-T68063-76 HORIZONTAL OR VERTICAL Ll 2% 6 2%4 Ixx:2.070 in Ixx:0.950 in: Ixx:0.330 m: m a
SID.TUBE MLn LION STQ„_TUBE MULLION Sxx: 1.035 ins Sxx:0.633 ins Sxx:0.330 ins e
SEE b1NCOW 0.R ODOR APF31DVN.FOR BG63-T8 6063-76 v
FASTENERS SIZES ANO SPM6NG g
Ixx:8.280 in: In:2.980 in; • a
a. sxx:2.760 i.,l Sxx: 1.490 Ina. c� E 2:s egg
CLIP LENGTH RECTANGULAR ALUMINUM TUBO MULLIONS : •I
USING MULLION PROPERTIES ONL
MDTy oL. INSTRUCTIONS: Y
USE CHARTSC MO P16 AS FOLLOW.
1 X'2 1.688' THESE MULLIONS ARE RATED FOR LARGE MISSILE IMPACT m+a+4'fj• �•`�3�M1�A�
STEP I DETCRU.M DESIGN I=REowxm FOR PARnW R OM . AND CAN BE usm w(rH ALL wwsoR's Mlaul-oAD- 6. ••• .�y+.�.
I X 3 2.688' COUNTY APPROVED IMPACT AND NON-IMPACT PRODUCTS.
1 X 4 3.688' RE
USE UIREMm aAnNc PRDDucls uEE6Nc 46011E ImD Oyq I1 �O O
x0rcx
. oPTwAAL 2 X 4 3.688' STEP 3 uARovFaN ro wwav rs PER wTOGucT NOTES
.125 uW. 2 X 6 5.688' STEP 4 SPEOFY MAm um SIB.sPA1TNG. - 1. REFER TO THE GENERAL NOTES ON SHEET-
x000 USV,O LUAUS 0.N SHEET 3 or 10 SELECT MuwoN VIE 1 OF l0 FOR BUILDING CODE COMPLIANCE d>3 I
1,ALL CUPS AND ANGLES-ARE TO FIT STEP`2-DEVGN R-, elprtE TIUN o2SFv LOM SPECImo s� I
SNUG INTO TUBE MULLIONS. IN 1111 1 ABOVE, 2. MULLIONS MAY BE ORIENTED VF.RYICALLY OR .••• ' i
ANGLE CLIP 2,WHERE ANGLES ARE NOT FIT SNUG USING ANGHCR TYPES ON a6ET 6 TWRt 9 mo MCHM CK,7,S HORIZONTALLY, v6•....
so6y-T6 INTO TUBE MUWONS,SEE OPTIONAL SIE ON SNEEr 9.SO=MCUOR TTPE.ToTH OEVGM WUIG 3.PREFER TO SHEET 1 OF 10 FOR TYPICAL UULLION AFFnn m
ANCHOR DETAIL AT SHEET 9 OF-.10. MORE T U THE OESCH IAMB SPEMW tv S2v 1 ieouE. ARRANGEMENTS OR STACK CONFIGURATIONS. o
PIP IS
X
MUWON
SPAN
oFbo i ;.bo b6b k. v b b
V
40.
r
zt,V; x
p p p 0.
lio za;j my's—S!6;418:12gHto;31;—sl F v Auk mlel INN.
W2 W7 g
o
'.@
IV tglpltlig
0
0 pa 8P
w ti 8 :1 r a ds a 5$
08.BmT
'1�4f" �4 i��p lb.44 p p
lo� 4�4
�4
Tf
8!g As 14
E
x
Gy,o$l,$Y f3 �Q1134�y 4 b.....
Is 8
mCi C.
THOM"J.twos
PRO F 0 WE08
A"M�—sf N.W.90 Si.
LA
o 56225 WSONFLOfUQA 33166
PH No.(3135)696-8660
�pr—vf m 5M Ult�(2Ot4)
TE 01 JfANVFA'ZrVRSR'OF 4VAInT ALUMINUM WINDOWS AND GLASS DOORS
ALUMINUM TUBE MULLIONS
UNREINFORCED TUBE MULLIONS DESIGN PRESSURE CHARTS AND GENERAL NOTES
DATE LAW-ML-IDGI 1-- 3 OF to
Ib9J
���+— .312 iMll.61111
.196 TVP. __ .129 T.C62 .125 30801.509 I _ 0m� 2 X d 5.000]4, 7000 24,118 m NpT�soD �� ' FRM1E E71 11 i
2I 6ll"I R CLIP •IBB I IQ .196 .102 1•IP9� m 3= ! O
2 X 6 F,lux� I I�z� 1 X 31.183--7 j i
NYria 'L• 6000 - 1 X 4 STD, TUBE MULLION 1 %3 d $
�•A• oPnDw,L M I N 7 X 4 STD. TUBE MULLION '. 1 X 3 x-16 CUi7OM MULLION }' y- G
CUSTOM MULLION
409)-T8 bDBs-T6 CUSTOM MULL ION
606)-T6 i C
Ixx:2.709 in: Ixx:4.709 in: ixx:2.768 A. Izx:2168 i Izx:2.278 in: g
J ) J Szx: )•445 in? Sxz: !.479 in)
Sxx:2.355 in. Sxx:2.355 In. Sxz: 7.445 in. e 2
2.000 (DANCE FRAIAF) (FLANGE FRAVE) (FM FRAME) .�
6TAxOARD TUBDIAR SxAPES 2000 a N
IVP.WALL .125'All O •�
ALLOY.fi063-T6 �.�0�
•�+ MAI..
FiA21NG PRuurcr
F v
2.000 329 2250 4000 � �
6009 112 sus.
ASP) 012•D.O. .<RME
1X MULLION -F 3.W0 1.000 8 R Elim
606J-T6 d
MULLIONS CONTAINING • 3�g
•� 'vc. '� .ZYPICAL GLAZING PROf�U�T,S caxsw x N
zRo�DD�cT„�`'
oPT�oNAL HORIZONTA •OR VGRT
SEE—DOR OR DOOR APPRDIAL FDR °
FASTENERS WES AND SPAC6YG
2 X 6 2 X 4 E
gTD.TUBE MULLION STO,TUBE MULLION F z M
Ixr.ISIX48 in: In: 7.649
ti•� 1. CLIP LENGTH Sx 6.549 in? S-3.825 ins
/ RECTANGULAR Al DMINUM TUBE MULLIONS •
rINSTRUCTIONS:
MULL "L' USINGLIPROPERTIES ONLY TIIIT/+IF.
USE CNMTS AND CRM6 0.S FOLLOWS, FOR LARGE
1 X 3 2688• STEP 1 0UERur+E DESIn EDu PMUIREO FDR PAxnclR.lx CIPM . THAND CANLIBE USED.RATED WRFi ALL LAL ..'SWISSILE M-I IDADECT '<,5' �3�N10%'41�•
xDTd+ 1 X a 3.688' STEP 2 UR[n'uiwzw PROOucrs ormG A6WE LOAD COUNTY AFPROyED IMPACT AND NON-IMPACT PRODUCTS.
y Im O:J
2%4 3.688• .BSEP,3 cmx m InnUDx As PET+PRDDucr NOTES: `� N to I
des Mw. 2 X 6 5.688' STEP_4 SPEm uAnywl smu sPAcm 1.REFER TO THE GENERAL NOTES 04 SHEET
L uyNG c uRrs Dx s�l 5 or ID SELECT Wi tmi Sa T OF 10 FOR BUILDING CODE COMPLUINCE. a W
1.ALL CLIPS AND ANGLES ARE TO FIT STEP wnx DE4Gx RAIDIc xm7E nNR DFSIGx ta0 9vRgYD 2,MULLIONS MAY BE ORIENTED VERTICALLY OR o ,�+y•,� G '
SNUG INTO TUBE MULLIONS. N STEP I ARNE.
ANGLE CLIP 2.WHERE ANGLES ARE NDT FR SNUG Dsxu ANCNDR IYPLS aN s•R¢r 6 nu+u 9 uD ANDRDR OwEs NOR4ONTALLY.'
fiM-T6 INTO TUBE MULLIONS.SEE OPTIGNAL STEP¢DN SHEET 9.SE=A.rcnDR TYPE w DESwx RA,l 3.REFER TO SHEET 1 OF 10 FOR TYPICAL MULLION ••Ty1NT6 �.I
�---2000--� ANCHOR DETAIL AT SHEET 9 OF 10. WRE TMI IME K� Labs SPEWED M S1EP 1 xiUM ARRANGEMENTS OR STACK CONFIGURATIONS. a
0
y
pp �rar pp (��a qq ppfbu
m N 0 0♦ g o A m V N�O�m N N O A 0 m N m O P W N m
�{
t W C
z
O A A J O o o A 41 J pp!-pp O L N V o 0 0 0 O 0 0 0 O 0 0 0 0 0 0 0 So O X
L N+ b,!'!'
m+N N W 00 o0o O!if o OCo oo O COCO W
ANLLION _ a
m
SPMI u'A r'n 'in r'n" •+-•.•.•'0mr+n m+vaao am++"H+0om0o+ �
' �No 0oa 000000000000000a000p oo00ao0 xp
AA 00000 oco 0o0oo0 000c 0'0000 oo 0c0 ocoeo o0 o000000a �
0
It " 00000000000 0 o o 000000 o o ob"000 o$oo 00 F. 0000 oxm
S g `I�r 0000 oo0 o0 co o o0o00 booboo oo000c00000000ccA
Z 9 m N N o tT N f+ii m to m P m m m u o o tJi, u'i fT t�]i N fT o m tl,Y,N O
m a 0 0 0 O O O O O O O O O O O O O O o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O O O O O O O X 2
o 0 o 0 0 0 o C G G O o o O o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o m W
q p O o O �.f q p
[Pf qq yyA W W N+m mN NO A00N Wm Op 0ZO1CTmN W OP0 VNNOp ptN oPm>-
VW N m O a m N m a
W2 W1 Y
.. 3
c
090 Z
0 z�m - +:im is is%.+>io in in in:i o,00mmo 0:+ Nora-.wA mint mo:iv 0m o� m
mOo � Z mo r
NImot a @
+ mLx z mr'umw°i mem$=mrmao ou oSm"urmnSmmo 0o�'�0+$'00 oxo
N �-1N mA V IJN o VAN+SIG+ �f+� O AV+�100N(nC O NG-�IJmC G o O G A A
a<y m a
N b mom)mA�b+JNm CIVnN+O N p
F,
OC mW m m N N m pp +N C
-1 V O O W 0 0 0 A W U O o O O o O O O O O O o.O O O O X O
� < C
m A m m m m m m m o o N WO m m m N m m Om m m mO J N O
A A V O O o 0 0 0 0 0 m 0 0 0 0 0 0 0 O O 0 0 0 0 0 0 0 0 0 0 0o 0 0 0 0 0 0 O X 2
CI A m O o o 0 0 o O o O 0 0 9.0 0 G 0 0 0 0 0 0 0 0 0 0 0 0 o G 0 G G c O o c c o 0 c m m
2
oVVyymqp �a�a e�.gaw uNA m.i�m gppau N+r
O YA S m O A m S Nuupp n
E
' 3
c
r
zz
+ m
a+N +mmou mm bmw AA X m
M m m N+ fT iD oA00tipz
W
T
'mmor�.vwknH'm+mc�abowm w+•nNrwa xo
+GUm V V IJ i11A tAbb,pA oomlD+iD i0+D7+V bfOG mAm V A m
m pro
a J¢ry mm+fNJ Q+mL rW0 V�Lm ON>V O W Wm N.P V N WtO�tWn GWO LfooO V W rWn 00N CAi+W T VE W�O X m
OlN toGo V NoGN(O i01JNG t0 fnGA+b,omm'A m, Ll G1 o a T
W S
r
THOV+Imii+ro A V O N m m o V W b+W[fT+m N m o 0+N m m m N N o 0+W A m m m m m N O
� N N O O m m 0 0 O N m 0 0 0 0. m m W m 0 0 0 0 0 X y
Pao EO N�V G'oG faGoO WmoiJGpl Glnmo o Norco Otn lnGo GO+miO m�JO G000 m
lEff .O:^• enwaew
Sz<u .p.- cna eNs •t LA ® ],T 8501 NX90 ST.
e
-a e•r n FOC- • �! 1 ®/ ..LEY.FLORIDA 33166
r •'" F Cem nce• roc 51n Edocn 10l,l) S R PH No.(305)696-8660
MANUFACTURER OF QUALITY ALUMINUM WINDOWS AND CLASS DOORS
?'.O•(y"�`e`' " o a o ALUMINUM TUBE MULLIONS
i� •,1
f 8 IraLr+r:t +�r..•er H.pu=b r"' pltr REINFORCED TUBE MULLIONS DESIGN PRESSURE CHARTS AND GENERAL NOTES
GU'+4 R►. i,�'c Mte1 al�.�.�Mrn a.o.,v•W,r, ,o
DATE_ _ - LAW-61L-1001 5 OF to
s/te•rAvtD.Yss/Is• � MIN. EDGE DIST.
t 1/4"MIN. 1_t/ER 2-�,,,t PD. 1-1/2•ICK.WDao PEA'EI1GnON 2-3/16'CONCRETE OR y
DGE DISE 2 Pan O An
ON t WDIc) I PUE ANGEE 4' OLLOY!BL CK 5/ls.rwcD,R s/ls•rzPCDWs o
1-J/1•MIN.ELDEO IMO Y.5¢VRr 1-3/4•YN NOED DRO YASONW
IN,
s PER CUP(z a Ud AtNC) 2 pmANGLE y 0
•
monO
' ii Ij 11 jj I 2 ~ y Q
11 11 Z C z d
1ii'a�__I 11 I1 t 2 7/16' H �I 11 uo�ra 2 O
------- f ix ROADDC CLIP li it AW4zML'LEa MIN. li I� �I it C07 d @ o
__
u --------------- 1 8r j1-a' li it L2 Y 2 x 1 j a 1
' WOOD BIICi! K"'• O B
I 1 I IV I WOOD&IDC 'I IY IIDATRG GUD u u Au,Y MLIF j
2 z I
' GO Q 3
E-*
e E t
3/4"MIN. s/ID•r.PrnNs ANG S, TYPE 'O' (INTO BLOCK �U
EDGE DIST. 1_1/2•Yw.WDOO PIMlMr10R � J
°CH ANCHORS TYPE 'O' (INTO CONCRETE) ® z
4 ANCHORS THRU 1X BUCK p'
ALL CLIPS AND ANGLES TO FIT SNUG 4 � a
INTO CONCRETE OR BLOCK p a
'
INTO TUBE MULLIONS.HE r,�W
�3 TAPCONS MAY 6E HEX OR FIAT HEAD. � 1'zA"&-2'x4'MULL �/ I �
11 c
a
' MIN.EDGE DIST.
i F"'..' 2
2-3/16•CONCRETE OR4'HOLLON BLO s/ts•TAPGDts 2 qr 1-2/K•YDIEYD.D DRO WSO•NY 1-]/�•IArt EYBEO R)YA W ro• z Prn n.w ft ox W+»xlPEA M GEE_AL -
�'YsANCHORS I P 'A'
E
2 ANCHORS INTO WOOD
.tar 11IL'-a`�l h
T. -------- O'D00 BUOc f l tx fIMANG cw 1 u M ANA
P
s/ts•rArcQs •
1 1/4"MIN. 1-1/Y ux vDDD PDmwnDR 1-1/Y un.uoro/'PSENEm m. u
E DI a PER QIP(2 Qv FAM tACJ 2 FER AKGtE I rF s <
ANCHORS TYPE 'C' (INTO BLOCK
�i ANCHORS TYPE 'F' (INTO CONCRETE
ff
2 ANCHORS THRU 1X BUCK •(Cyp?Srti::})Ad
INTO CONCRETE OR BLOCK >>'• ��g AAA
AWY2ANG ANGLE 1
REVISED REVLSp••
___ r •� DAAiDIG ClN acn4'scad,i�OlefMSiI
I I 1 I I ! DPddxlg Code �y/y2 Q•�
N I I 2 Lti 1 I V V i 1 Aa•PtmLCa •[iF'GI.I
\ 1 I WOOD BACK 1 1 1 -- _�
�
1 tSm•DtzB Prod 1
ANCHORS TYPE '8'
4 ANCHORS INTO WOOD
AACIIDRA`LOGDY)X '/Illl!!li•••1tL\
c
5/IC tgPCONS '
J/.•Lva mem ono IusavRt MIN.EDGE DIST.
MIN.EDGE 01ST. _ z
OR WP(r ON MH MNO) s Is'racroxs C
_ / 2-3/ EOR 5/Is'WOONS 5/Is'rwrnNs o
2 �fifi LLOW BE OR - 1-J/a•wl.ENo[o wro wsaanr 4' IOLLOV!BL CK 1-J/a'uw.EusEo mto YawNRr }_J/+•MN.mem wro lusoum• v yy
4 HOLLOW BLO K -3 1/4- IPO+anus +Pm ctlP(z on Enol tw�c) x PEx axaE F
MIN
t _ .•I n !I MIN o I I I q o 0 2
O
p
u
CONCRETE OR
CONCREtE OR CELENf BLOCx �I Ii II ICOn1AElEaNw
_________ kyr B10Cx -J ii ii nEuuza s - n n
I I 1 'NIL aNC1E 5
nWm aP rR Twe cw " ? z S
I 2 7 16 ra
MIN. ' j o s
1 i i
i '
e F5�
- — 3 1/4-
Z3
4 a
MW MULL j Z_ Z
ANCHORS TYPE •C• (INTO BLOCK) ANCHORS TYPE V (INTO BLOCK) <
ANCHORS TYPE •F' (INTO CONCRETE) ANCHORS TYPE •G INTO CONCRETE)
r ' 2 ANCHORS INTO CONCRETE OR CEMENT BLOCK 4 ANCHORS INTO CONCRETE OR CEMENT BLOCK
I'x4'&2"x4'MULL q =
KIENNatE
I AVCfAR lfX.1t10n z Z
6
1 I j4:— CONCRETE OR •=,+II � Qo
0
• -1 �}�,, I I r I • V I I
5/m,taPCONS Z + 61
}..J/<•NttA EMBED - - '�� • > E
wr7
p2 PER 0.W - $ $ •TSj
ON racN xac) L5 ts•raPconS I
IP(2 xne Ya50NRs '
lan PER cEro(z ivpE ON ual wwty
\x<
Imo- _" x{ II ii GS �,.•_`i�v J+T.yt/%/ .j I ALL CUPS AND ANGLES TO FIT SNUG :4,41 •'�,)
TATO TURF MUWONS. PRODUCT REVISED x.•LJ ca ti-'
1APCONS MAY BE HE%OR FLAT HEAD. tunplying+rilh the FTaret4. •:C '.�3 .y
':J
PlNieo Ode :� e N %,�
/ 'z .•I CUPS OR ANGLES CONNECTED DIRECTLY i0 MASONRY TO BE PROTECTED
na 1 WITH ALKALI-RESISTANT COATINGS, SUCH AS BITUMINOUS PAINT OR OY a'4C�• I
WATER-VRRTE!AEIPACRYUiE IACOUFR. M Dnue P�>c5x+ f'ryfHt""Paaaat wl
s/18•iIFCONS
ARY I-J/+•Yw.EYBEO 0
' Nt0 YASO -1 PFR a:1OLF �.
' S
` MIN.EDGE DIST. MIN.EDGE DIST.
2-3/16•CONCRETE OR 2-3/16•CONCRETE OR
4'HOLLOW K 3_ � 60/16TAPmNa'HOLLOW BLOCK 3-3/4' s/sraD
MIN, 1- muD -3/ y
PER UOELH MIN. e
•PEN CUP(Z ON Ol-IPRC) C
..��' I I M y z
CLIP LENGTH 3
Nem v
MULL. o
1 2 X 4 3.688• � � y �
2E
o i o z0
<'
t o
t ler m i i
I1 ]se NI,SL 9{I6'TMCGYS • pODD BUCK 6 ••
1-3/0 YW.L1IM0 IWO&1H NA50r<4T 2x5 l9fLL 5/16•TAPCDN6 O
{ a P?i CIR(2 CR EACN WaC) S/a-—E46TD AR'D LL.SG— G7 Z L
___---_--_--I 1 3/4" a PER CDP EI CN EIa1 WJ.c)
t 1
D m s
MIN. 1 3/4" 7 4
3/4• 1 MIN. .fypE,
CLIP LENGTH zcfi Nuu H a r
a4 uuLt _
MULL 'L" I a a
�i l �i R%4 3.688• � _________ �� � rc�gg
3_3/4"
NI N.
5 11/16" ALL CUPS AND ANGLES TO FR SNUG ANCHORS TYPE 'E' (INTO BLOCK) F s a
INTO TUBE MULLIONS. ANCHORS TYPE 'H' (INTO CONCRETEI ley k
ANCHORS TYPE 'E' (INTO BLOCK TAPCONS MAY BE HEX OR RAT HEAD. Wood 6vtx 3
4 ANCHORS TIARU 1%BUCK my
f1NCHORS TYPE 'H' (INTQ CONCRETE) CLIPS OR ANGLES CONNECTED DIRECTLY TO MASONRY TO BE PROTECTED WTO CONCRETE OR BLOCK $ S
ANCHORS INTO CONCRETE w BLOCK I YRTH ALKALI-RESISTANT COATINGS, SUCH AS BITUMINOUS PAINT OR 2'%6"NULL SHOWN ^ G
2'1(6•MULL SHOWN WATER-WHRE NETHAGRYLATE LACQUER €_ `�-' ggpg i •+
PPP,OVUCTREIASEO �2 M D•;
mp1YTR4 ail6 Dx FW"
�103fxY
� I
II
4
D
MIN.EDGE DIST. s/,a vacs s CLIP LENGTH
a
2-3/T6"CONCRETE OR 3/A`M8.EMBED a,D MAstwAr 3-3f A' 11
4�IIOLLOW 8L K • •TWAL(7 m E"x T)-- MIN. MULL "L' w 4 2
i i X 2 t.688• rn ii
I X 3 2.688'
•'� •f `
-TX 4 J.6BB' ~'Io'�
` IF
2 X 4 3.688'
2X6 5.688• ir ! rn c
E
e 2-2f T6' r i 1.ALL CUPS AND ANGLES ARE TO FTT o o z
s MiN. a•m 2a6 2 x Z X,/°. SNUG INTO TUBE MULLIONS. x
° - AUIu AN 2.WHERE ANGLES ARE NOT FR SNUG m a R J
i-------------� L} t i INTO TUBE MULLIONS.SEE OPTIONAL y t
ANCHOR DETAIL AT SHEET O OF 10. ;$ o
:a z Se
S.M.i 5 = � •a
CLIPS OR ANGLES CONNECTED DIRECTLY TO MASONRY TO BE PROTECTED 2/clunln. TUBE UJUAN +i
WITH AUEAU-RESISTANT COATINGS,SUCH AS BITUMINOUS PAINT OR s L
WATER-YAEITE METHACRYLATE LACOUER. ---- --------- V j }n
e Z z
--------
MIN.EDGE DIST, ® a• y;
2-311V CONCRETE OR
b 4
4'HOLLOW SLIT K /,2 r. s.
2/SV i I .
W w a
,Ie•I.."MUM vtomiEL
iY
IU6R+INTO w W I ,UBE uuIUON ti A,
+ WSES WlY DE HOTCRED
. AS SYO4R iD MLOW MS,MU11pN
I 1 'DF CHv 10
+ CAIAX JW ATTER ASSEMBLY 6 .
LOCATION OF SCREWS CONNECTING
ANGLES TO TUBES WHERE ANGLES /s PER�
ARE NOT FIT SNUG INTO TUBE I f I f f ASESs RaLE s-,72`n.c.>AIL
MULLIONS. ' - O O - i I I
r
5(B'{z} -
----- --- ----- -- -- a
L- ----------- -J I I N n
Y 3•
st,c vpcc,4 it.sus W `
-J/�eCY.EYBfd Rrt0 IA+SOM'/ ♦PEA ANGLE I
POi.WGtE , ------
----,• --`--- -----
2x c
Z I Z i Ij$• MS SORE.CAN OE I /t2 EN SMS a
% MSfASED M TDMA
"""."` O DREG OH fib- ;c.- $g � i
-]/•"X Z'i,/A'Ira+2tTYY
�z
J/A•X 2X f/B•FDA(t@Y EMBE) 4
• h WT ro r[i SEAW WE M ++,+LyiaY.ta'rj3Af+A,
w 0. -- =G==------ ANCHORS TYPE.
'.f•�
METAL TO METAL CONNECTIONO:GJ cC7 ':_`�•_
USE CHARTS FOR ANCHOR TYPE Y TO VERLK CAPACHT OF TAOCONNECTKIN
OEIC7 HItMLSGT? g��,,,�.
CM
ALL CLIPS AND ANGLES TO FR SNUG INTO TUBE MULLIONS.TAPCONS MAY OE E1EX OR TNT HERO.
OPTIONAL ANCHOR DETAIL a
MIN. ANCHORS WTO CONCRETE OR CEMENT 81-OCK
I
4
.FYF�
Ig 8
t'IS Hl
is
g gigig g gig 0§gigigIg g g gig g g g
9 gigIg 1 g 4 gig gig 21a:fie a ggg g'I
MOM g gg
B 6 99999
9 g 99
gig g till -§Ig a 9 atjrilgj�g g1gigig 9 9
+K--9- IS I ;-T-s-Fs:M-,,T-u--f
SPAN
A.
> Qn m
R A Po !2 r 14 k t B na T 13 r a f4 R;it bit a a
6 0=ou, IR?I v
zo 0
0 D fib V 4&T 2 a8 !4 a It It a s 9 6 a v s R III w a g m a a v a 0
wc ta a a 2t is
morn
8 41311miall g 61919 g g gig g nIg g g R g g I;g g§Iil§l§
v
0 (4 6+1151918 Ise
z
z 1
,a),m z
tz
z I
Az gig g
0
umm,sm Aaf!)V! a a a ZA 31415 g 1
0
O R om
Id fs A t[a 0;Z m a 5: !4 a I:a 4 2 s El 1%g g t t IS III a a a a a v a s
Ia -1 olsk
F.
a B
tal!l&kiss a�a q 11151-1111 a a$0 a-1+111 difs f8ift+a of 8 9 8 v III a&Z lie ml+'§11
. ..... si; ,Boa B gigg.
is Mggssa 210 m I a
J.som
0
FWSON 8501 N.W.90 ST.
SU25
'r- MEDLEY.FLORtDA 33166
PH No.(305)696-8660
C.Q-'6a— FBC SN Etlllion 201.)
OF MANUFACTURER OF QIJAUTY ALUMINUM WINVORS AND CLASS DOORS
N—7. zn�'. ALUMINUM TUBE MULLIONS
N.rn= Aom CUP/ANCHDRS DESIGN PRESSURE CHARTS AND GENERAL NOTES
DATE- C LAir-3fL-1001 SC op to
JUL 13
MIAMI-:ADE PEF,�+� R; MIAMI-DADE COUNTY
9 St. Lucie t::, . i.. PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISIONT(786)315-2590 F(786)3I5-2599
NOTICE OF ACCEPTANCE .k O aaa . ovieconom
Lawson Industries,Inc. , 4 �� �, ✓
8501 NW 90 StreetL �� '�str
Medley,FL 33166
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control
Section(In Miami-Dade County) and/or the AHJ(in areas other than Miami-Dade County)reserve the right
to have this product or material tested for quality assurance purposes. If this product or material ;fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER
reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code,including the High Velocity Hurricane Zone.-
DESCRIPTION:
one:DESCRIPTION: Series 11811--7700(Flange Frame)" Aluminum Single Hung Window—L.M.L
APPROVAL DOCUMENT: Drawing No. L7700-0901, titled "Series-7700 Single Hung Flange Frame
Impact Window", sheets 1 through 5 of 5, dated 05/27/09, with revision C dated 09/21/16, prepared by
manufacturer, signed and sealed by Thomas J. Sotos,P.E.,bearing the Miami-Dade County Product Control
Revision stamp with the Notice of Acceptance number and expiration date by the Miami Dade County
Product Control Section.
MISSILE IMPACT RATING:Large and Small Missile Impact Resistant
LINMATIONS:Insulated Glazing Options Types 6 and 7 are not approved to be installed above 30 feet in
height without external protection device(shutters)
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, series,
and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA.Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed,then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises and renews NOA No. 140908.10 and consists of this page 1 and evidence pages E-1
and E-2,as well as approval document mentioned above.
The submitted documentation was reviewed by Manuel Perez,P.E.
MIAMI-DADE COUNTY NOA No.16-1003.01
Expiration Date: December 27,2021
��lfp Approval Date: December 15,2016
f Page 1
Lawson Industries?Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
A. DRAWINGS
1. Manufacturer's die drawings and sections.
Submitted under NOA No. 09-0706.09
( )
2. Drawing No. L7700-0901, titled "Series-7700 Single Hung Flange Frame Impact
Window", sheets 1 through 5 of 5, dated 05/27/09 with revision C dated 09/21/16,
prepared by manufacturer, and signed and sealed by Thomas J. Sotos, P.E.
B. TESTS
1. Test reports on: 1)Uniform Static Air Pressure Test, Loading per FBC,TAS 202-94
2)Large Missile impact Test per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked-up drawings and installation diagram of an aluminum single hung
window,prepared by Hurricane Engineering &Testing, Inc.,Test Reports No. HETI-
09-2530A and HETI-09-2530B, dated 03/02/09, signed and sealed by Candido F.
Font, P.E. (Submitted under NOA No. 09-0706.09)
2. Test reports on: 1)Uniform Static Air Pressure Test,Loading per FBC TAS 202-94
2)Large Missile Impact Test per FBC,TAS 201-94
3) Cyclic Wind Pressure Loading per FBC,TAS 203-94
along with marked-up drawings and installation diagram of an aluminum single hung
window, prepared by Hurricane Engineering & Testing, Inc., all Test Reports No.
HETI-08-2003C, HETI-082004A, HETI-08-2060A & B, HETI-08-2061A & B,
HETI-08-2062A& B, HETI-08 2063A& B, HETI-08-2064A & B, dated 03/15/08,
signed and sealed by Candido F. Font,P.E. (Submitted under NDA No. 08-0825.17)
3. Test reports on: 1)Air Infiltration Test,per FBC, TAS 202-94
2)Uniform Static Air Pressure Test,Loading per FBC TAS 202-94
3)Water Resistance Test,per FBC,TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC,TAS 203-94
6)Forced Entry Test,per FBC 24113.2.1.1 TAS 202-94
along with marked-up drawings and installation diagram of an aluminum single hung
window, prepared by Fenestration Testing Laboratory, Inc., Test Reports No. FTL-
2987 and FTL-2986, dated 04/03/01 and 03/27/01, all signed and sealed by Luis
Antonio Figueredo,P.E. (Submitted under NOA No. 01-1009.01)
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC,
prepared by Lawson Industries,Inc.,dated 05/28/09,revised on 01/18/10,signed and
sealed by Thomas J. Sotos,P.E. (Submitted under NOA No.-11-0705.09)
2. Glazing complies with ASTM E1300-09
7A�31
Man el Perez,P.E.
Product Co"r Examiner
NOA No.16-1003.01
Expiration Date: December 27,2021
Approval Date: December 15,2016
E-1
i
Lawson Industries,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
D. QUALITY ASSURANCE
1. Miami-Dade Department of Regulatory and Economic Resources(RER).
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 14-0916.11 issued to Kuraray America,Inc.for their
"SentryGlast7(Clear and White) Glass Interlayers"dated 06/25/15, expiring on
07/04/18.
2. Notice of Acceptance No. 14-0916.10 issued to Kuraray America,Inc.for their
"Butacite®PVB Glass Interlayer"dated 04/25/15; expiring on 12/11/16.
3. Notice of Acceptance No. 14-0423.17 issued to Eastman Chemical Company(MA)
for their"Saflex Clear and Color Glass Interlayers"dated 06/19/14,expiring on
05/21/16.
F. STATEMENTS
1. Statement letter of conformance, complying with FBC-5" Edition (2014), and of no
financial interest, dated September 30, 2016, issued by manufacturer, signed and
sealed by Thomas J. Sotos,P.E.
2. Statement letter of no financial interest, dated 05/28/09, issued by manufacturer,
signed and sealed by Thomas J. Sotos,P.E. (Submitted under NOA No. 11-0705.09)
3. Laboratory compliance letter for all Test Reports No.HETI-09-2530A&B,issued by
Hurricane Engineering&Testing,Inc.,dated 03/02/09, signed and sealed by Candida
F.Font,P.E. (Submitted under NOA No. 09-0706.09)
4. Laboratory compliance letter for Test Reports No.HETI-08-2003C,HETI-08-
2004A,HETI-08-2060A&B,HETI-08-2061A&B,HETI-08-2062A&B,
HETI-08-2063A&B,HETI-08-2064A&B,issued by Hurricane Engineering&
Testing,Inc., dated 03/15/08, signed and sealed by Candida F. Font,P.E.
(Submitted under NOA No. 08-0825.17)
5. Laboratory compliance letter for Test Reports No. FTL-2987 and FTL 2986, issued
by Fenestration Testing Laboratory, Inc., dated 04/03/01 and 03/27/01, signed and
sealed by Luis Antonio Figueredo,P.E. (Submitted under NOA No. 01-0406.08)
G. OTHERS
1. Notice of Acceptance No. 14-0908.10, issued to Lawson Industries, Inc. for their
Series"SH-7700 (Flange Frame)"Aluminum Single Hung Window—L.M.I.",
approved on 11/06/14 and expiring on 12/27/16.
Manuel P e" .E.
Product Control xa finer
NOA No. 16- 03.01
Expiration Date: December 27,2021
Approval Date: December 15,2016
E-2
NAT+PtM1AtIOV PNCeGNS. `-VINDOMr RNfw FINS VIDO+ MpDV FLOMC[MAh<viEM tNSTALLPTIDM axpylS� VMfIDV f'.uC,C TRINE VIDIN
AIL AT FR+ME KAD IwS;ALL.iDN MRUp2SR5 1 ur+N k Pr TY.�f 12P➢ V,
..
T6 i/MS�JRMDS rwT SKIT 4+r Q 1 q14 DC.� 21 WPE REP FRPVi SILL V MA%iry[. Ql �fitG�PNE Et'I I E$SK;Ef F 1 O�
i
! (G[RNti.uN3S tSEE SNEEr FO +
4.VAIt-M.O
ALL CORNERS)
•
1.43 9/16
rM+L Pa1vE c �" ) ..1✓ Nn
�aaz :u m DnB•
3, l—Al "peg Y m5.i q o
12 •b :X ;; _ ^w ? 6�R41L5 J '____ 1' ' Y� 8'16GID& _-_. _„ C U
eaRW
MAL DC:GV y - MEETING RnR - __ ! __ - 1 py - / ' ° •`®� 1• ,
wEEt[MG SAR� // o -IF / •� �i�T$ ji' �E' [� ` A, e
T b, r
EXT l INT,
FALSE CT-TIAL
@ ONItd WIINSNARE AwV%IEPAL
lE^D• —52.125•--..- I
i
MUNTMS ARE APPLIED Vi i� -�- -- V/ILAM+LL'AND
v III`^�TO
MKIv DIDt VICDI VMAY C.MY VIDIx _ .[Dl-
"OLE
V/SILIEGfiT Aho ARE � AVP0.AW,C PS OP�10+4L. ^- VIwWV BNTX VIDTM
pYP OLE AS CPTIDWL 48"x 78"EQUAL LITE ELEVATION UN-EQUAL LITE RADIUS ELEVATION UN-EQUAL LITE ELEVATION PPP�vv 333...f�'I 44 a
°)YCLUDES UN-EQUAL LITE AND RADIUS HEAD (LIMITED TO LOADS ON SH4 OF 5) (LIMITED TO LOADS ON SHEET 4-OF S) 4 I
(LIMITED TO LOADS ON SHEET 4 OF 5) Z
General Notes- SERIES-7700 SINGLE HUNGIMPACT
IMPACT WINDOW — FLANGE FRAME +A
1.)THIS WINDOW SYSTEM IS DESIGNED AND TESTED TO COMPLY NMI THE REQUIREMENTS
OF THE 2014 FLORIDA BUIL=G CODE 5th EDITION INCLUDING HIGH VEIOCDY HURRICANE Mzta.L+itOV NsrcRs.—. vvDw RNN?vxPME vmrx it
ZONE VELOCITY(HVHZ)AND ASTM 1300-09.THIS PRODUCT IS IMPACT RESISTANT. vAX Ar rRNF MEPC.
iHi irB2 YSR FRaM[SRL' l3 JI+•
(SH( NOT REQUIRED) ti FeNF.AweT<TCE sw,{{+u —1 M4X OG S o
2.)WOODD BUCKS SHALL BE SEDINSTALLEDAD AND ANCHORED SO THAT E R QUIREME
RESISTS THE SUPERIMPOSED LOADS IN ACCORDANCE WITH THE REQUIREMENTS
OF 2014 F.D.C.&TO BE REVIEWED BY BUILDING OFFICIAL t CORNERS c 2
3.)ANCHORS SHOWN ABOVE ARE AS PER TEST UNITS. ANCHORS ON ALL WINDOW SIZES MA O.LO.W;U •' .9
ARE NOT TO EXCEED THESE MAXIMUM SPACINGS ON CENTER(D.C.)AND AS TABULATED
ON SHEET 4.
4.)ANCHOR CONDITIONS NOT DESCRIBED IN THESE DRAWING'S ARE TO BE ^n 9 Sr0• ____._)i��/.PS_= 8 +
ENGINEERED ON A SITE SPECIFIC BASIS,UNDER.SEPARATE APPROVAL AND $ RAa.ABO ✓%• 6",
A a
TO BE REVIEWED BY BUILDING OFFICIAL y. . E
5.)WINDOWS ARE QUALIFIED FOR USE WITH SINGLE GLAZE LAMINATED GLASS F
TYPES TABULATED HEREIN(SEE SHEET g3),AND FOR USE WITH DOUBLE GLAZE g
LAMINATED INSULATED GLASS TYPES TABULATED HEREIN(SEE SHEET 13). +'p_�
e.)SEE SHEET 3 FOR LOCK DETAILS&OPTIONS. , ' • c' ,¢ I i! 3
7J SEE
SHE
4 FOR DESIGN PRESSURE AND GLASS TYPES.
B.)FOR OPTIONAL FRAME INSTALLATION DETAILS SEE SHEET 3.
9.)W.
&INT.FALSE COLONIAL,MUNTINS ARE OPTIONAL&A-40 ARE APPLIED W/SILICONE BELGv
10.)WOOD BUCKS IN CONTACT WITH CONCRECE MUST BE PRESSURE TREATED AND ANCHORED tSETR6 mtt,s, �I. o n
y/
BY
OTHERS),PRIOR TO WINDOW INSTALLATION. SEE SREET 2 FOR DETAIL&NOTES -1-- F PR d a
( ) ( s ) Of]UCTR5VISED z ��. �••7�
WOOD BUCKS TO DE ANCHORED IN COMPLIANCE WITH THE 2014 FDC CHAPTER 24. La' Bw: »Dswwm,F(cae,, agi• p`...•°"°°+`• A !
SECTION 11.3.3.3. G• Aaxpm n (b.b pt fly , b u
11.)APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE MULLED UNITS.
12.)MULLING SINGLE HONG WINDOWS WITH OTHER TYPES OF MIAMI-DADE COUNTY APPROVED )M t •�-- !• W
WINDOWS USING A M)AMI-DADF,COUNTY APPROVED MULLION IN BETWEEN ARE ACCEPTABLE EXT.4•NT•FALSE CSSDNtaL ,C ? -�, • C•?'�B
BUT THE LOWER DESIGN PRESSURE FROM THE WINDOWS OR MULLION APPROVAL WILL APPLY, NLWIINS°ARE APPLIED vi htM, 14Vtlen � � �^ Ry,,•' h
TO THE ENTIRE MULIED SYSTEM. pt St IC
@.E AND ARE viNaw DLu v1BSN -� .y.
13.)SEE SHEET @ 3 FOR NUWON/METAL ATTACHMEAT DETAILS&OPTIONS. YARABLE AS DPTIGNKL { y
14.)
ALL
METAL/STEEL IN CONTACT WITH ALUMINUM OR OTHER DfSSINBAR MATERGIS TO BE EQUAL LITE ELEVATION ,__Jp��V,.'• _`'"YD i
(LLMITED TO{DADS ON SHEET 4 OF 53 �:�''•,..,..,C`�':�
PAINTED OR PLATED AND SHAH NEST SECTION OR OOH OF THE LAR FLORIDA BLDG.CODE. 'PAT, � ,+.•ap
I
i
TAPEEIN V/I I/4• XN SxS v/I yr '�
HIN.EM.BEDRENT L*tS0 EEStt. ALL
VODD BUCKS ENGINEERCB SEPARATELY HD:EHB mvr INTO MCC. Lw TEp egg .PT- mc BECYS �
IEEE ELEVATION AT SHEET tlI E 3E 4LVSF.YED BY BLDG,RFFiLSAi CTYa,) FOR me.11mR SHEET ) A o
r p.T VODD BUC<NOT BY tAVSON IND FOR MAX FASTE/tER SPACINS)
FOR MAX.FASTENER SPAC[NTiX ! SgtST SUSTAIN IHPOSED WARS SILECo x ADKSIVE O a y
I vR•xIN. I4 23 BEDDING CNNOUND
p U 1/t•rAPCON V/ V4'
qB IR INTERIOR T MIN."GEWENT 1 tNtD Ct3�t. ;
t 1 59 •ISEC ELEVATi¢ T 9kZX Al <� V
• .ptDECNEM'NT + ~ FOR MAK FAVENTR SPA43 O
_ !•; 12 i2 i tJv RtN - x p ~
N I i/i'HIN. CVA. O w A. a W i
ain
3
�. . EDGE D(STA.:CE o
EXTERIOR GRADE i •. j o
PERIRETER CAULONG 1 4- Z n
i9 l O B - .. j J
tG t SILI—c ADHCSIVE EXt,CRAOE ' EXTERIOR D K
y.
PERINCTCBEDDING CCYPL D CAULK CXTERIOR TRAP _ IM
^
IM
I R CAIX.f
—MATED Q-.. ({ —m.FRAY'u viDTil ���111 O i
24 C
IGHE v/1 1 4• I^NT YJKD014 TNS]'t1LLATIPA NOM•S,^ °� <
p��— Rw.ERBeB�xT ONTO vma gam.�sT„ c. 3
INTERIOR SCE ELEYATILH AT VW I.THE vIN011V FRAME(LANCE TO RE BACK-BEDDED V/AN C%I. a iE
R Ct!$NG t0 fpN MAX FASTENER SPACWG> GRADE CASK TPROVGHOUT THE ENTIRE PERIMETER UP FLANGE V
EXTERIOR E.,..UE EXT.GRIDE BY WINDOW D STAt1.CR HETE
CAIILK� THE EXPOSED E%i.PERIMETER pF THE VWCOV FRANC TO
BE SEALED V/AN APPROVED EXTERIOR GRAEC CAULK 4 f
[HN�N DY OTHERS ITYRI j II p
14.H/1 5 •VMEN THE CAP REMEEN THE MDOW FRAM£X%D THE BUCK O.4 IN
" 9 Al ti=15 tTHAN i/0 E'HW ARE NOT REQUIRED. ..
8 � ' gYCRORS NOTE;
a' I ANCHORS TO BE tie SHS OR WD.SCREWS INTO WOOD,OR
0 IT ( ( 1/4'TAPCCNS or APPROVED CONIC,FASTENERS INTO CDNC.. g o
f n y..
j 1
WITH A N(NIHUH OF 1 t/4'PENETRATION INTO VfFJD ER
6°
t4 CONC.IREFER Tp LEIAD TABLES AT SHEET 4 OF 5 FO.R
OUANTITi£S REOOIRED> Z �a
e2��u
��rtrt��ll j „ ra,E
CaERS�METER fAA1�AKWG 2 ] 1/4'MAX. G .`«,6,T�Nty'^�,
SHIM
TYP •ttOU£`FRRYiSPA] `d� •��.'�~•' /�N e 1
A. ,A .Nn t6-1 p m .Z .`•'v P, t
ly
A • a
EXT,
WOD BU'A.�'KDY
O
I
NLN'. ELEDISVT LATD SWEET
z, 1) LSEE ELEVAiI@I AT SHEET 01 6 6 26 C ��
z
FOR
NA%.FASTENER SPACINW INTERIOR c
na v"V.cc
EJ
- •SCLIUK O+iIG9f•: M1ORiDa TI FA I
_
NOT BT LA—
----------------------
3131
eaAa+c�rx - - ni a:a wu ecDmxc 25 21 vii a v
vamv u'¢z,lO1Aei6 er o q p• o y
u WnrED c1Ass aar6attDN-nre z a n psrAuw nrr� 5 P o w e a
ria
A--
DRAG UYIXNe DLAA 3 h
D a,a � �. wisps m rrt E""•"qo'"`"'`" ,�"6'ca LOCK (LATCH AND SWEEP) OPTIONS $W i i
ar DiITAi L m m e a a Af o i
t v,•MIN. { - __ I.BOTH EXTRUDED ALUMINUM AND PLASTIC IJtWIT RMV(E
LAMINATED GWS LTIYPOSITfON-TYPE 0 i-'+ LOCKS ARE QUALIFIED FOR USE ON ALL WINDOWS. a E., c
cue.+ovLwnm I Dena uXDun DesDnl•imN -� 2.BOTH DIE CAST AND NYLON CAM LOCKS ARE QUALIFIED a n
f ve•A.RALED uA:s ""'•'sw".,•':S:^,�:K. -- FOR USE ON ALL WINDOHS.
v Gd U I
TWO s f
x msD•aLAs+lc rvrtx.arrR �a EXTERfOR
(2)LOCKS ARE REQUIRED PER EACH tBh7.
/B',ro6KC➢4An 1� :�::"�:':.'.;-•�[xl.GAGE KRir¢i[R �/g/
J - - - ULLXIrL tim p ® W
UYWATED GLASS
COMPOSITION-TYPE a CI IAMB ���pa6+SBiei OnsRY � EI
RM 0....06LBIRIION DCrYL uvpun OLBCWPOON V
e'AvnCALCD LYtf I _ ill[C9 OVER 16TH.4.AfN xA Al iD O N
T BDiACItt we y CLrEFiG GAR F31 1—OR
2 D090•PLNtIc IxirAlAr(A -� - 1 y� �a yc, r0 BE SPCLVaO Br q¢pNi[Ci DR DG Z y
J_,/B'NKKEO GENS v.v7 r 149 fp15.R 011@ 4
- AUi Br t4V5@+IN➢Usly_,[NG � C' 1 y
.T A, IYOOD FRAME INSTALIAT�(IN DF7A(j,
UIITTIAY-`LO 61A55
COMPOSITION-TYPE D
Rd CIAn Of[EODITTIpf OLGa T uRpAn 06A'OPiro. A1.1X91M14—LION
IM'NCAi- TEID'D 6N1[ f &+i.+LIrL v KY y ICE YIFLLJOL.A PROVKS FOR 0 la X]/a•Spy- SEE YVv W Fa NAl5 Y
JrtOAArG a,iz NULEEIr1(rPE 42E ANO IlA)L rLAT+CAp,PNIl1fPi UL•.Lbl+r]'PL 42E AND usr
J VB•+GT-SrRL\rt[KD 4/.LS -S a~�T DESIGN PRFSURE U—ONS. (SLE ELEVATMN A4p C6CN FR[SW E L-TAT—
W.W.OAIB'NW.THOC) CJ'TABLES rTR`U TITY INTERIOR NOTE•TK IDAEF PRESSDRES Dv'S.Ml
0 FASTENER IPACIWD xkAC tANCOA DR MVLL)Mut GOVERN C
KJ'E I++E ON OR PRESSURES DF'ENN /,•JIAX.
l I x+ WNG iT.Ntla OR VAL SPALL CD+ERM � SHIM
INTERIOR I z SU.S.X i /.•
IEE ELEV.ECR$POLL G
z] A
•safo+E mors, - _-•_� 1giJdg�
a _ imw srt rev:z NOTE: e E
aw C
IIS KPp L ALL STFIl IN C0.•+TACr LVIN
ALW.ST FE-ES OR 11AT9. y v w
INNUTATED fANIli�TED G COMPOSITION Typ 0 l� z.ME,u Si4,1CLURESY Y D )
A)4EEL
Rfll OI.L6➢r.YCIRiION eTea rAnN.n ORLWPIIpN I-- (51E0.Is FA Y9L R+'CIC-C.OA87 S i e u
1 Ve'IC,T-YTROr;,1rKY LLASS �- PflDMETER W�NWW lF.+uE BJ KUMNL'V:605]-15 RN. •< Fd g L
Imm RlNifc wEm,rtR - ___p vl: l TERM
.EXTR ER EXTERIOR O 1{
I.e•wsr-nec+r IENLD wsz 1 � sFK/urt (AtOu DDIB'nv.TNICX) 5
t/+•IRMgrCD Ap SP,VI +{6 r•CCrf wB D, PERNEBC GRABE E'1
IK'AWA:CD CliS ® rt avarol Am•k•,Dc PEFINEIER CAULX)NG
B FRAME MIJLLING DETAIL METAL STRUCTURE ATTACHMENT DETAIL
INSULATED LAMINATED GLASS C0�51'(-0.4EL10 TYPO T ...BI.... �
irM Gr...D�CR+PNO!i DRAG wmun ROA—.ve•waKCD nAs� @FDDOcr� o`` p.•.••• •••••A/�U'�'�
z re ttA`rrt ntti.-w "L Du WT40 s,isbUl➢viXs� �. .-,•LV IT R_G•:��
p f•JLwey rmv cAr: .:y o o:
J •.Nc cD as -_:___ Ell—a.sm sv n+'avrmsD ra,I6- �/ •;z u
v.•paurtD.w SVKE IOO� g1�2I o=i :W � ;j'
5 +e•gA+LKLD rAAss I �
Gym`
Gi.AZTNIG DETAILS AND OPTIONS hiae
+i
1
s
N(P NmW NmW NiD b m W m W N.V '•L
A W N aawwmp a
N V m N V m N J N V Q '•m N V N •• N V N"
�tN)f
0+-
...MF1ppp
m amz 0
WN N N N N N N=
mmenmtn M p 11°' � mmmm mmy O
n D
mmma�m qm m m m m m m m p/m m m m � Pm.mmm mmm mmm mm.mem mmmm mm c `
fO 0 0 0 0 P 0 40 O O 000 O O O G 000 p y ' m ono nOOq OOO OOa n 0 p000000000 y.0
O 000 O O 60 O 00 00 0 0 0 C 0000 "I G OOOo OP00 000 G00 0000.000OOOOb -1 C
O ? L1b2
v mmm mm mmmm mmm mm mmm m 0 .m mmmm mm..........em.m mm `•'Do
�o Q o 0 00 0 Q 0 00000 O o o r�o m wood Popo P. PPap pPPoop 000pp�,d
0 0 0 0 O O 0 0 O 0 0 0
0a 0 0 0 0 0 0 0 .1 m P O O O C 0 0 0 0 0 0 0 0 O O O P O O o 0 0 0 0 0 V o m
\ b
Z %2
V m m m m m m m mmm W m m mmmm . 1CN V mmm m.mm mm...m.m.....mmmm. b
m
mo00000000000t7o OQooOamffi 2 masa Popo pooaoa ooa000 oopoao mn x
0 0 0 0 O 41 0 0 0 0 0 Q O Q O 0 0 0 0 0 0 N 0 0 0 0b p 0 0 0 C C o 0 0 0 0 0 0 P O O o C H
0 01 t
D-
M
>> yN 11nn GGtt m > N > p
mN V W a W mN N�vf,L„i�N V�•rMm��uf�NwNm9/W.f.iDNw�m W mN Yq+m,cmi GaN V'rmj�tlli�S�
Ell
Ww.
V V V V V m m qq �j' O m4�•�i O p����n m� �,y Nr.1 rN�
m NAd.aaa o�W�j V 1�. W bbd W��W TNm{n iQ3, c�W ty. ywt�. �93239,m�i�
n�
E
B- 1
7 p
mm @@ ¢g W m
ffi ffi�ffi��y��iffioffiffiffigoffi,c.�o Poo N� x
O O p ...... G p O O O p 0 C p O p O.....
O
m a
�mffi ��SooS"op�mn$}°affi8o�ffic$a5o$$F.8r3�oS �S�Ywfb
I� P O O O O O o n o o PCO C O o 0 0 0 1}a f}O O O p O e O P O O bo...
P
EB-
0
gds ffi& a.Y' .... .........b..ffib ......;ffiyS'mbpp�2
oo aopo oaa boaobo bbp�bo oo 000a �3g
I
0 0 O C 0 0 0 0 O D O O O O a G 0 0 C O P O 0 0 p O p 0 0
m
y~ O
�$$$ .....S. .o 5�ffio$f3i5�$ SSB F3 x$$110 P
v�
, p ib9� o .
po6opoPop oP Pop.o oP Pobo cO aoae000poa omo oo
•lA ,�plT h� ...iw.rte.« �• ggJ'�pg/7"{®`^{ ���qqq
�� •�G$522 g A Y Y OJ O
y •,cft� 9 J BSOi N.W.90 5T.
'0 65225 m ca, mt.m< MEDLEY, FLORIDA SS766
#T e. e...a Pry Na.(305)696-8660
• � � c. Fm.o• me sm Ea an z..
¢ Of •: ,,,eistxn-m MANUFACTURER of gUALITY ALUMINUM WINDOWS AND CLASS DOORS
a,�.• p;'\aw+^ dj N.MAzo M-V-QR ,S,F,${�, ,Z3.4Q...tiINCFLE HUNG FIeANS�'% FRAME QA�,T NII��tY
Sr -7'r:c.I: N.Erosc a'•osRt to DESIGN PRESSURE CHARTS.k CONFIGURATION OP[[ONS
DATE a.�w o '�`�"r�"`" L77'00-0001
6
FRAME READ FInD MEETING RAR• O BILL OF MATERIALS
L-7701 L-7704
(D1�) �( ITEM/ PART B READ. DESCRIPTION REMARKS_ y y
f O I 1� I FRAIAF TOPQ.Q3dEg 1 L-7601 1 FIN FRAME HEAD 6063-Tb ALIMIhLR o CW
2 L-7W2 1 FIN FRAME SILL 6067-T6 ALUMINA( '4 o
5¢t r52 I 3 L-7803 2 FIN FRAME JAMB 6063-TG AL tax
4 L-7704 i FRAME FIXED MEETING RAII 6C63-T6 ALUMINI-N In o m V
I 4'4 and 5 L-7705 I VENT MEETING(TUP)RAIL 6063-T6 ALUMINJN m 0 2
I VCNT BDT70M(LATCH)RAIL6C63-T6 ALUMIVU4 3 R
�2w� 1 7 L-7707 2 VENT JAMB(SIDZI RAIL 6063-T6 ALURINL7( I 6 3 •:J 2,
4 (per .A B L-7708 AS REO'3.GLAZING BEAD(3/8') 6063-TS ALLMINUM �.r a u
9 FS-006 AS REO•D.FRAME ASSEMBLY SCREWS M8 X 3/4•PA PHILLIPSm o. R -v
FRAME SILL FRAME.JAMB 10 FS-040 AS REOLIINSTALLATION SCREWS 014 X 1 1/4• FN.
/PHIL.
L-7702 L-7709 qe j � o I
O ( d m ) 11 L-7331 AS REO-11 BULB VINYL WTSR V4'DIA.BLLD 03033 : n
z f c4ea-ts.(nll[4�113 O �t � BAV&_d�Pj 12 PVS-G03 AS REO'R FIN SEAL VFgTHZR$iRIP
13 PVS-003 AS REO'D.F'.N SEAL WEATHERSTRIP .187'sJ50'
�)44) 14 PWS-009 AS RECD.FIN SEAL WEATHERSTRIP .187'x.310'
Z'a) 15 HC-024-1 2 SELF ADHESIVE PILE PAD 1/4•X 1 I/2' + F
16 L-7711 AS RECD.GLAZING BEAD/INSULATED6063-75 ALUMINUM
24•a 17 L-42_04 AS RECD.GLAZING BEAD-RADIUS 6063-TS ALUMINUM
10 L-7723 I SASH BALANCE CAM/QUIRE (2%VCNi)
_
19 L-7725 2 RIGID VINYL SASH STOP JCL%FRAME) a:
20 L-7727 2 BLOCK 6 TACKLE BALANCE I BSI Bo1EnCe Systens
21 L-7539 2 VENT LIFT LATCH 6063-T5 ALIDLNUM I ( o I
L113 I m 22 L-7523 Ix LATCH VENT LATCH SPRING STAINLESS STEEL
23 AS REO'D.G-AZING SILICONE SEE GLAZlk..a SMT.3 m
VENT INTERLOCK RAIL VENT BOTTOM RAIL x
VENT JAMB RAIL f9AVf 5xt O 29 x 2 Lnrvnotea Muss SEE CuAZIRG DETAILS
L-77051 mu-m Armux 1 L-7706 L-7707
25 NC-OST-I 2 VENT LIFT LATCH f
Y.OLDED h1•L0N • o j
7 tam-m euxmv) FRAME ROTT017 CORNER 26 MC-058-11 2 VENT SWEEP LATCH MOLDED NYLON
u7s--I p� 27 x 2 FRAME SILL FOAM GASKET SELF ADHESIVE
2B HC-026-1 1 SCREEN FRAME 6 MESH d I�
` t, O 29 L-7730 1 PRODUCT LABEL
VENT TOP CORNER 30 x x
zuz I �`� x s '• v
� JG2 1 �__. .II: lJ 31 SM-5504 AS REO'D,JOINT SEALANT SM-SSO9 S - � 3 c i
iii 32 JAS RED-D.1 PERIMETER ACRYLIC CAULK 0S1 PCLTSEAMSEAL a
IGLAZIN BES L-7711 GIAZINO READ O�
VENT SPRING SATC11 GLAZING-7711BRAD
L-7539 L_4284
<4z (aem_m.:u.$)v) (wo-m uux:A>,• 1 Oma- —� ............
:ROWCTRLYISEU
_� 4Y 13.wldog)LbOn)4'eid4
II Ad �PtlW4 i4o 1�n�00 �� •:C Ll 1
' �� T I.I� VENT 90T70M�ORNCR
BY -�Q••'•
n
iii•'/.•.'..• I
(,�•,�,y,,,.vy) �w4e� FRAA.fE& SASH CORNER DLTAII s `������� � ,Y �5�i�
Q
LI