Loading...
HomeMy WebLinkAboutBuilding Permit Application ALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED F Date: 7/13/2017 Permit Number: J� • Building Permit Application Planning and Development Services PERMITTiNG Building and Code Regulation.Division St. Lucie Gaunt\`, FL 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772)462-1553 Fax: (772)462-1578 Commercial Residential X PERMIT APPLICATION FOR: Roof PROPOSED IIVIP,ROUEMENT LO.CATIO:N . , M., Address: 4531 S Indian River Dr, Fort Pierce, FL 34982 Legal Description: 36 35 40 THAT PART OF N 91.86 FTOF S 1598.88 FT OF GOVT LOT 2 LYG E OF FEC RR WITH RIP RTS-LESS RD R/W-(0.50 AC)(OR 545-51 ; 1853-546) Property Tax ID#: 2436-324-0004-000-8 Lot No. Site Plan Name: Block No. Project Name: Setbacks Front Back: Right Side: Left Side: DETAILED DESCRIPTION O'F WORK a; ce r^4 f( �.''g ¢Ja xr rir S T:' a,n'U•'"R:y Re-Roof Shingles. VA-L9k)q[e_ CONSTRUCTION .INF`ORM`ATIO'N a . .:._ . . . _n. .x E, Additional work to ff orme under this permit—check all appy: HVAC �Gas Tank Gas Piping _Shutters Windows/Doors ❑ a 11 Electric 0 Plumbing Sprinklers I Generator 17 Roof Total Sq. Ft of Construction: 3200 S Ft.of First Floor: 3200 Cost of Construction:$ 7520 Utilities:[]Sewer W1Septic Building Height: OWNER%LESSEE CONTRACTOR . „ Name Richard W Crowe Name: Roderick Waller Address:4531 S Indian River Dr Company: Sunrise City CHDO, Inc. City: Fort Pierce State:FL Address: 3550 Okeechobee Rd Zip Code: 34982 Fax: City: Fort Pierce State:FL Phone No. Zip Code.: 34947 Fax: 772-907-0420 E-Mail: Phone No. 772-201-2850 Fill in fee simple Title Holder on next page(if different E-Mail: rodwallerl@gmail.com from the Owner listed above) State or County License: CGC1515114 If value of construction is$2500 or more,a RECORDED Notice of Commencement is required. L 777777 SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION 5 , e a W. „", 3 du"` xa..,��", wA,, DESIGNER/ENGINEER: _Not Applicable MORTGAGE COMPANY: _Not Applicable Name: Name: Address: Address: City: State: City: State: Zip: Phone: Zip: Phone: FEE SIMPLE TITLE HOLDER: _Not Applicable BONDING COMPANY: Not Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: I certify that no work or installation has commenced prior to the issuance of a permit. St.Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure.Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will,in all respects,perform the work in accordance with the approved plans,the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review:room additions, accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory uses to another non-residential use WARNING TO OWNER:Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before comme.Qcing work or recording our Notice of Commencement. i /ib OL- -1 oa-o�vs _Signature of Own r/Lessee/Age Signature o Contractor/License Hol er STATE OF FLORIDA, C� STATE OF FLORIDA COUNTY OF COUNTY OF The forgoing instrume t was acknowledge fore me The forgoing instrument was acknowledged before me this. day of 20 l!by this a day of 20 19—by —R(!) (Name of person acknowledging) (Name of person acknowledge ) (Signature of Notary Pub ic-State of Florida) (Signature of Notary Public-State of Florida) / Personally Known 7 OR Produced Id ntification v/ Personally Known ✓ OR Produc d Identification Type of Identification Produced �L• U.L5 ,m ype of Identification Produced L O,L, Commission No. N CS NIELSEN ommission No. I (seal) Commission# FF 115res ppy Commission Expires t -- '�'�lf Revised 07/15/2014 . Commission# FF 115637 My Commission Expire- REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE COMPLETE INITIALS I P`•='. l'"l F— ��1 JUL 3 2W7 A PER"fl,11 1ING MIAMI-DADE COUNTY lq$y1.13�4DI 5t. Lucie Count, F!_ PRODUCT CONTROL SECTION REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 llE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE OA q rpm ga . � nwww.miamidade. ov/econom o. Owens Corning Roofing and Asphalt,LLC 1 ` y One Owens Corning Parkway r = ,� Toledo,OH 43659 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify,or . suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Oakridge®,TruDefinition Oakridge®,and TruDefinition Oakridge®Artisan Colors Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 12-0430.01 and consists of pages 1 through 4. The submitted documentation was reviewed by Gaspar J Rodriguez. NOA No.: 15-1102.03 MIAMI•DAD,COUNTY Expiration Date: 02/03/21 Approval Date: 01/21/16 Page 1 of 4 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Asphalt Shingles Materials: Laminate Deck Tyne: Wood SCOPE This approves a roofing system using Oakridge®,TruDefinition Oakridge®,and TruDefinition Oakridge® Artisan Colors asphalt shingles manufactured by Owens Corning as described in Section 2 of his Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications . Oakridge®, 131/4" x3 93/s" TAS 110 A heavy weight,fiberglass reinforced laminate TruDefinition Oakridge®,and asphalt shingle with continuous bead of TruDefinition Oakridge® sealant. Artisan Colors Manufacturing .f g Locations#1,2,3,4 Oakridge®, 131/4" x 39 3/8" TAS 110 A heavy weight,fiberglass reinforced laminate TruDefinition Oakridge®,and asphalt shingle with dashed bead of sealant. TruDefinition Oakridge® Artisan Colors Manufacturing Location#1',2,3,4,5 MANUFACTURING LOCATION 1. Memphis,TN 2. Irving,TX 3. Savannah, GA 4. Jacksonville,FL 5. Atlanta,GA EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date PRI Construction OCF-153-02-01 TAS 100 09/22/10 Materials Technologies OCF-152-02-01 TAS 100 09/21/10 OCF-158-02-01 TAS 100 11/10/10 OCF-151-02-01 TAS 100 09/27/10 OCF-150-02-01 TAS 100 09/21/10 OCF-165-02-01 TAS 100 01/07/11 OCF-170-02-01 TAS 100 06/06/11 OCF-177-02-01 TAS 100. 12/05/11 OCF-178-02-01 TAS 100 02/02/12 NOA No.: 15-1102.03 MIAM I-DADE COUNTY Expiration Date:02/03/21 Approval Date: 01/21/16 Page 2 of 4 Underwriters 09NK14530 ASTM D 3462 12/31/09 Laboratories R2453 ASTM D 3462 10/11/10 R2453 ASTM D 3462 11/03/10 R2453 ASTM D 3462 10/11/10 R2453 ASTM D 3462 10/11/10 R2453 ASTM E 108 01/13/11 R2453 ASTM E 108 10/11/10 R2453 ASTM E 108 11/03/10 R2453 ASTM E 108 10/11/10 R2453 ASTM E 108 10/11/10 09NK14530 TAS 107(ASTM D 316 1) 12/31/09 R2453 TAS 107(ASTM D 316 1) 10/27/15 IONK13947 TAS 107(ASTM D 316 1) 11/12/10 R2453 TAS 107(ASTM D 316 1) 10/11/10 R2453 TAS 107(ASTM D 316 1) 10/27/15 IONK13947 TAS 107(ASTM D 316 1) 01/28/11 11CA15662 TAS 107(ASTM D 3161) 05/27/11 11CA65092 ASTM D 3462/TAS 107(ASTM D 3161)/ASTM E 108 02/14/12 11CA40912 ASTM D 3462/TAS 107(ASTM D 3161)/ASTM E 108 11/30/11 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. '3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail W, attached. 5. Nailing shall be in compliance with Detail'B', attached. LABELING 1. Shingles shall be labeled with the Miami-Dade Seal as seen below, or the wording"Miami-Dade County Product Control Approved". MIAMI•DADE COUNTY �lUI...O BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. NOA No.: 15-1102.03 MIAMI-DAD;couNTY Expiration Date: 02/03/21 Approval Date:01/21/16 Page 3 of 4 DETAIL A EDGE OF ROOF -------- i i i i 13" THIRD COURSE 7.. SECOND COURSE L i i i FIRST COURSE j ME/ j i DETAIL B 39 3/8" 13-1/4" 61 g � � 5 5/8" EXPOSURE Lj END OF THIS ACCEPTANCE NOA No.: 15-1102.03 QMIAMMI-D�ADE COUNTY Expiration Date: 02/03/21 Approval Date: 01/21/16 Page 4 of 4 ' ^ � or5 rive 647 CREEK a TECHNICAL , K~�~K�� L *s�s -�=- `.°- p - � EVALUATION REPORT FLORIDA BUILDING CODE,6^EDITION(2014) Manufacturer: l7\MKO BUILDING PRODUCTS,INC. Issued August 22, 20Y0 pI\ Box 14V4 Joplin � (417)G24'8044 JUL � % ���7 ~�� / ° ~~^` Quality Assurance: UL LLC pERlO|TTMS SIL. Lucie Couoty, FL SCOPE Roofing Subcategory: Underlayments Code Sections,.- 1507.2.3, 1507.2.4, 1507.2.8, 1507.2.9.2, 1507.3.3, 1507.4.5.1, 1507.4.5.2,1507.4.5.3, 1507.5.3. 15075.3.2. 1507.6i3, 1507.8.3.2. 1507�.5.�1507I8. 1507I3.2. 1507.8`3. IL507��.2, 15078.8.T15078. 15079.3. 1507.8.3\2. 1507�.5. 1507�.9 Properties: Physical properties � Rspsmsmosm E at-i ty Year pR|constmction|mgoena|nTvvono|ouios 04e TAP-.1 91-02-01 REV ASTM 5 1970 2009 pR|-ConvonohunMaterials Technologies o*e T4p'192-02-01 ASTM D 197 0000 PRI onmmrunonnMme�a/oTed bnomnina�o76u4n r�P�o�uu-o1 ASTM o1V7V »V»n PmConmmn6onmom6a�To:6no|ogieo(TOT6048) TAp'u14-02'01 ASTM D4809 2005*01 PRI Construction Materials Technologies 04e TaP'215'02,01 ASTM oo2m uuoa PRI Construction Materials Technologies 049) TAp'21o02-03 ASTM on000 e003(2009) PRI Construction Materials Tovhnn|nmieo 049) n^P'217'02'01msv ASTM oVnno moun(zVVn) PRI:ConstructionMatenulsToowno|ooies 049T*p'2n'ou'o1 ASTM oo2n 21006 PRI Construction Materials Technologies m*o TAP-219'02-01 ASTM 000V 2008 pFu'oonmmn6onMaterials Technologies 049TAP-220'02-01 ASTM oauao u000(eooe) pm/Construction Materials Technologies(TmTnn49) Txp-,222-02*1 ASTM Ci4VVn 2005oo1 ,PRI oonotruoonnMaterials Technologies(TSTno4o) TAp`319`02-01.1 ACC188 .2012 uLLLC(TSToa2o> 13cA12269 ASTM ouu6 u000 PRODUCT DESCRIPTION AND APPLICATION � TAKoKO@)ASTM Slate AGTW1D8380.Class M.Type Uundodo ontconstructed from organic��It saturated Surfaced,Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules. Min.slope: 2:12 Application: The undedeymentshall bei�utoUedw4mminimum 2^ side laps.and minimu 4^staggered end laps and in accordance. with FR8/VTR| 07230 for U|o applications. Allowable roof coverings: Attachment ofasphalt shingle valleys and clay and concrete tile oho|| be permitted in accordance with thoFDC. ToP14001 i y CREEK TAMKO BUILDING PRODCUTS,INC. TAMKO Underlayments TECHNICAL SERVICES,LLC TAMKO@ ASTM Tile ASTM D 6380; Class M,,Type ll underlayment constructed from an organic felt saturated Undeflayment with asphalt then coated on.both sides with asphalt and surfaced with granules. Application: The underlayment shall be installed with minimum.' side laps and minimum 4"staggered end laps and in accordance with FRSA/TRI 07230 for tile- applications, Allowable roof coverings: Attachment of clay and concrete tile shall be. permitted in accordance with the FBC. TAMKO®Master ASTM D 6380.,Class S,Type IV underlayment constructed from an organic felt saturated Smooth with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. Application: The underlayment shall be installed along the valley in accordance with FBC requirements. Allowable roof coverings: Attachment of asphalt shingle valleys shall be permitted in accordance with the FBC. TAMKO®Moisture Self-adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane Guard Plus® with a mineral surfacing and a removable.release film on the adhesive side. Application: The underlayment shall be attached by adhering directly to the roof deck with minimum 3-1/2" side laps.and minimum 6"staggered end laps. Min.application temperature: 40°F. Allowable roof coverings: Attachment of asphalt shingles and mechanically fastened concrete and clay 'tile roofing shall be permitted in accordance with the FBC. TAMKO®No.15 ASTM ASTM D:926,Type I underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt Application: The underlayment shall be installed with minimum 2" side,laps and minimum 4"end laps. Allowable roof coverings: Attachment of asphalt shingles, metal roofing, wood shingles; wood shakes, and roll roofing shall be permitted in accordance with the FBC. TAMKO®No.15 UL ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt Application: The underlayment shall be installed with minimum 2" side laps and minimum 4"end laps. Allowable roof coverings:: Attachment of asphalt shingles,metal roofing, wood shingles,. wood shakes, and roll roofing shall be permitted in accordance with the FBC.. TBP14001.3 FL12328-R7 Page 2 of 4 This evaluation report is provided.for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,.LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. CRDEEK TAMKO BUILDING PRODCUTS„INC. TAMKO Underlayments TECHNICAL SERVICES,LLC TAMKO®No:.30 ASTM ASTM D 226,Type II underlayment constructed from a non-perforated organic felt that.is. .Asphalt Saturated saturated with asphalt. Organic Felt Application: The underlayment shall be:installed with ni'inimum 2"- side laps and minimum 4"end laps. Allowable roof coverings: Attachment of asphalt shingles; metal roofing, clay and concrete tile, slate shingles, wood shingles, wood shakes, and roll roofing shall be permitted in accordance with the.FBC. TAMKO®No.30 UL ASTM D 226,Type II underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt Application: The underlayment shall be installed with minimum 2" side laps and minimum 4"end laps. Allowable roof coverings: Attachment of asphalt shingles, metal roofing; clay and concrete tile, slate shingles, wood shingles, wood shakes, and.roll roofing shall be permittedin accordance with the FBC. TAMKO®TW Metal and Self.-adhered, flexible,, ASTM D 1970, rubberized asphalt sheet membrane with a Tile Underlayment polymer film on the surface and a removable release film on the adhesive side. Application: The underlayment shall be attached by adhering directly to the roof-deck with: minimum 4" side laps and minimum 6"staggered.end laps. Min:application temperature: 40°F Allowable roof coverings: Attachment of asphalt shingles, metal roofing; and mechanically fastened clay and concrete tiles shall be permitted in accordance with the FBC. TAMKO®TW Self-adhered,. flexible, ASTM D 1970, rubberized asphalt, sheet membrane with a Underlayment polymer film on the surface and a removable release film on the adhesive side. Application: The underlayment shall be attached by adhering directly to the.roof deck.with minimum 4" side laps and minimum 6"staggered end laps. Min.application temperature: 40°F Allowableroof coverings: Attachment .of asphalt shingles and metal roofing shall bep ermitted in accordance with the FBC. TAMKO@ TAM-FELT Alternate.to ASTM D 226,Type I and Type.11 underlayment constructed from a hon- perforated organic felt that is saturated with asphalt. Application: The underlayment shall be installed with minimum 2"' side laps and minimum 4"end laps. Allowable roof coverings: Attachment of asphalt shingles shall be permitted in accordance with the FBC. TBP14001,.3 FL12328-R7 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61.G20-3. The manufacturer shall notify CREEK Technical Services,,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This-evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 1 ` TAMKO BUILDING PRODCUTS,INC. CREEK TAMKO Underlayments. TECHNICAL SERVICES,LLC LIMITATIONS 1) This evaluation report.is not for use in:the.HVHZ. 2) Fire Classification is not within the scope of this.evaluation. 3) Wind uplift resistance in"not within scope of this evaluation. 4) Installation.of the evaluated_product shall comply with this report,the FBG,and,the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 5) Minimum application temperature shall be-50°F unless otherwise noted. Contact the manufacturer when installingat temperatures below the minimum application temperature. 6) Deck substrates shall be clean, dry,and free,from any irregularities and debris. All fasteners in the deck shall be.checked for protrusion and corrected prior to underlayment application. 7) The roof deck shall.be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be installed'in accordance-with FBC requirements. 8.) Unless otherwise stated,the minimum roof slope,.shall be in accordance with FBC requirements. 9) All.uriderlayments shall be installed with the roll length parallel to the gave,starting at the eave., and lapped in successive.courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 10) The underlayment maybe used as described in other current FBC prod uct.approval documents.. 11) The.underlayment`shall not be installed over existing roof coverings. 12) Contact the manufacturerfegarding.specific axposurer limits for each underlayment. 13) All products listed in this reportshall.be manufactured under a.quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code,,5th Edition(2014)as evidenced in the referenced documents submitted by the named.manufacturer. ,•`�G`c�P'RY•R •p9i��-., 2016.08.2 No 74021 2 09:35:3-9 5 � STATE OF ;' '��' 'c� P•' �� -Zachary R. Priest,P.E. .��,�.•, . O R•tp•••�N`�. rY Florida, Registration 021 Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE 'CREEK Technical Services,LLC does not.have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical,Services,LLC is owned,operated,orcontrolled,byany company manufacturing or distributing products under this evaluation.. Zachary.R.Priest,P.E.does not have;nor will acquire,,a financial interest.in any company manufacturing or distributing products under this evaluation. Zachary.R.Priest,.P.E,does not have,nor will acquire,a frhancial interest in any other entity involved in the approval process of the product. 'I END OF REPORT TBP140013 FL12328-137 Page 4 of 4 This;evaluation report is provided for State of.Florida product approval under Rule 61.G20-3. The manufacturer shall notify CREEK. Technical Services,,LLC of-any.product changes,or quality,assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use, or other product attributes that are not specifically addressedherein. I