HomeMy WebLinkAboutNotice of AcceptanceMIAMI.
Mo:A3DE.
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NO
MIAMI-DADE COUNTY
ODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
"786) 315-2590 F (786) 315-2599
Iwtve_miamidadc.vnv/ecnnomv
Iko Industries Ltd.
40 Hansen Rd. S.
Brampton, Ontario CANADA
L6W3H4
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Cambridge, Cambridge HD, and Biltmore AR Asphalt Shingles
LABELING: Each unit shall bear a permanent label with the manufacturers name or logo,, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and here has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the man
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 14-0603.02 and consists of pages 1 through 4.
The submitted documentation was reviewed by Gaspar J Rodriguez.
MIAMI-DADE COUNTY
�EW:10(41140
or its distributors and
NOA No.: 16-0329.13
Expiration Date: 05/05/21
Approval Date: 04/21/16
Page 1 of 4
ROOFING ASSEMBLY APPROVAL
Category:
Roofing
Sub -Category:
Asphalt Shingles
Materials:
Laminate
Deck Type:
Wood
SCOPE
This approves a roofing system using Cambridge AR, Cambridge HD, and Biltmore AR
manufactured by IKO Industries Ltd. as described in Section 2 of his Notice of Acceptance.'
PRODUCT DESCRIPTION
shingles
Product
Dimensions
Test Specifications Product
Description
Cambridge
13 3/4"x 40'/8"
I
TAS 110 A heavy y w
l fight, fiberglass reinforced
Manufacturing Location 41, 2, 3
laminate asphalt
shingle.
Cambridge HD
13 3/4" x 40'/R"
TAS 110 A heavy weight,
fiberglass reinforced
Manufacturing Location #1, 2, 3
laminate asphalt
shingle.
Biltmore AR
13 3/4" x 40'/8"
TAS 110 A heavy weight,
fiberglass reinforced
laminate asphalt
shingle.
Manz facturing Location #1, 2
MANUFACTURING LOCATION
1. Kankakee, IL
2. Wilmington, DE
3. Sylacuaga, AL
EVIDENCE SUBMITTED
Test Agency
Test Identifier
Test Name/Report
Date
PRI Construction Materials Inc.
IKO-050-02-01
TAS 100
12/21/09
IKO-076-02-01
TAS 100
02/21/12
IKO-114-02-01
TAS 100
09/25/14
IKO-099-02-01
TAS 100
05/12/14
IKO-096-02-01
ASTM D 3462
09/27/13
IKO-095-02-01
ASTM D 3462
09/27/13
IKO-121-02-01
ASTM D 3462
09/25/14
IKO-100-02-01
ASTM D 3161 (TAS -107)
05/21/14
TKO -115-02-01
ASTM D 3161 (TAS -107)
09/25/14
FM Approvals
3041689
ASTM D 3462
02/23/11
3036971
ASTM D 3161 (TAS -107)
01/04/09
3042673
ASTM E 108
04/12/11
NOA No.: 16-0329.13
MIAMI•DAD; COUNTY
Expiration Date: 05/05/21
Approval Date: 04/21/16
I
Page 2 of 4
Y
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofii
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the'f
Rule 61 G20-3 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 1,1
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail W, attached.
5. Nailing shall be in compliance with Detail W, attached.
LABELING
1. Shingles shall be labeled with the Miami -Dade Seal as seen below, or the wording "1
Product Control Approved".
MIAMMADF Cnt 1NTY
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Oficial or the applicable
evaluate the installation of this system.
Materials Directory for
Building Code and
ami -Dade County
in order to properly
NOA No.: 16-0329.13
Expiration Date: 05/05/21
Approval Date: 04/21/16
Page 3 of 4
--24 -"----------
i
i
—14"
L
4'—
L
"—
i
i
FIRST COURSE
DETAIL A
CAMBRIDGE, CAMBRIDGE HD, BILTMORE AR COURSE LA
OF ROOF
Note: Roofing Cement not shown in this layout.
This drawing is for course l4out only. See Detail B
for nailing and cement placement details.
THIRD COURSE
SECOND COURSE
DETAIL B
CAMBRIDGE, CAMBRIDGE HD, BILTMORE AR
40 8"
1 it ---i 1 n
END OF THIS ACCEPTANCE
1"
5$" EXPOSURE
NOA No.: 16-0329.13
Expiration Date: 05/05/21
Approval Date: 04/21/16
Page 4 of 4