HomeMy WebLinkAboutGAF_Asphalt_Shingles_Florida_Approval_FL10124_R19BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL # FL10124-R19
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parisppany, NJ 07054
(800) 766-3411
mstieh@gaf.com
Authorized Signature Robert Nieminen
lindareith@trinityerd.com
Technical Representative Beth McSorley (current)
Address/Phone/Email 1 Campus Drive
Parsippany, NJ 07054
(973) 872-4421
bmcsorley@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
the Evaluation Report
Robert Nieminen
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 03/03/2018
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL10124_R19_COI_2016_01_COI_Nieminen.pdf
Referenced Standard and Year (of Standard)Standard Year
ASTM D1970 2009
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
TAS 107 1995
Equivalence of Product Standards
Certified By
Sections from the Code
Page 1 of 2Florida Building Code Online
1/19/2017http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquracBeVCbdM...
Product Approval Method Method 1 Option D
Date Submitted 08/26/2016
Date Validated 08/26/2016
Date Pending FBC Approval 08/30/2016
Date Approved 10/13/2016
Summary of Products
FL # Model, Number or Name Description
10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab, laminated, 5-tab and hip/ridge
asphalt shingles
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Refer to ER, Section 5.
Installation Instructions
FL10124_R19_II_2016_08_FINAL_ER_GAF_Asphalt
Shingles_FL10124-R19.pdf
Verified By: Robert Nieminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL10124_R19_AE_2016_08_FINAL_ER_GAF_Asphalt
Shingles_FL10124-R19.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
Page 2 of 2Florida Building Code Online
1/19/2017http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquracBeVCbdM...
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPORT
GAF
1 Campus Drive
Parsippany, NJ 07054
Evaluation Report 01506.01.08-R21
FL10124-R19
Date of Issuance: 01/03/2008
Revision 21: 08/26/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: GAF Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. Trinity|ERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words “Trinity|ERD Evaluated” may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 08/26/2016. This does not serve as an electronically signed
document. Signed, sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity|ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity|ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval proc ess of the
product.
5. This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
Exterior Research and Design, LLC. Evaluation Report 01506.01.08-R21
Certificate of Authorization #9503 FL10124-R19
Revision 21: 08/26/2016
Page 2 of 6
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the
following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations /
Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.4, R905.2.3 Physical Properties ASTM D1970 2009
1507.2.5, R905.2.4 Physical Properties ASTM D3462 2009
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2009
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2008
1507.2.7.1, R905.2.6.1 Wind Resistance TAS 107 1995
3. REFERENCES:
Entity Examination Reference Date
GAF (PDM 1915) Letter of Equivalency Seal-A-Ridge Impact Resistant IR 01/13/2012
PRI (TST 5878) Physical Properties GAF-025-02-01 03/27/2002
PRI (TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004
PRI (TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005
PRI (TST 5878) Physical Properties GAF-324-02-01 12/01/2011
PRI (TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013
UL (TST 1740) ASTM D3462 93NK6295 11/29/1993
UL (TST 1740) ASTM D3462 99NK43835 01/12/2000
UL (TST 1740) TAS 107 94NK9632 03/29/2000
UL (TST 1740) ASTM D3462 01NK06632 02/02/2001
UL (TST 1740) ASTM D3161, TAS 107 01NK9226 05/21/2001
UL (TST 1740) ASTM D3161 01NK37122 12/18/2001
UL (TST 1740) ASTM D3462 01NK37122 12/19/2001
UL (TST 1740) ASTM D3161, TAS 107 02NK12980 04/10/2002
UL (TST 1740) ASTM D3161, TAS 107 02NK30871 09/09/2002
UL (TST 1740) ASTM D3161 03CA5367 03/11/2003
UL (TST 1740) ASTM D3462 03NK26444 10/17/2003
UL (TST 1740) ASTM D3462 04NK13850 06/07/2004
UL (TST 1740) ASTM D3161 04NK13850 06/23/2004
UL (TST 1740) ASTM D3161 04NK30546 03/10/2005
UL (TST 1740) ASTM D3462 04NK22009 05/06/2005
UL (TST 1740) ASTM D3161 04NK22009 05/09/2005
UL (TST 1740) ASTM D3462 05NK27924 02/10/2006
UL (TST 1740) ASTM D3161 05NK27924 02/11/2006
UL (TST 1740) ASTM D3161, D3462 06CA18077 06/05/2006
UL (TST 1740) ASTM D3161, D3462 06CA18074 06/16/2006
UL (TST 1740) ASTM D3161, D3462 06CA35251 10/18/2006
UL (TST 1740) ASTM D3462 06CA31603 12/01/2006
UL (TST 1740) ASTM D3161, D3462 06CA41095 12/27/2006
UL (TST 1740) ASTM D3161 07NK05228 03/13/2007
UL (TST 1740) ASTM D3161 06CA31611 04/04/2007
UL (TST 1740) ASTM D3161 06CA61148 04/09/2007
UL (TST 1740) ASTM D3161, D3462 07CA31742 11/08/2007
UL (TST 1740) ASTM D3161, D7158, D3462 08CA06100 03/13/2008
UL (TST 1740) ASTM D3161, D3462 07CA55908 04/01/2008
Exterior Research and Design, LLC. Evaluation Report 01506.01.08-R21
Certificate of Authorization #9503 FL10124-R19
Revision 21: 08/26/2016
Page 3 of 6
Entity Examination Reference Date
UL (TST 1740) ASTM D3161, D3462 09CA10592 03/26/2009
UL (TST 1740) ASTM D3161, D3462 09CA06856 05/15/2009
UL (TST 1740) ASTM D3161, D7158, D3462 09NK06647 08/01/2009
UL (TST 1740) ASTM D3161, D7158, D3462 09CA27281 08/27/2009
UL (TST 1740) ASTM D3161, D7158, D3462 10CA35554 03/05/2010
UL (TST 1740) ASTM D3161, D7158, D3462 10CA13686 05/15/2010
UL (TST 1740) ASTM D3462 10CA07264 05/27/2010
UL (TST 1740) ASTM D3462 10CA11953 10/29/2010
UL (TST 1740) ASTM D3161, D7158, D3462 10NK11951 10/30/2010
UL (TST 1740) ASTM D3161, D7158, D3462 10NK12070 11/04/2010
UL (TST 1740) ASTM D3161, D7158, D3462 08CA06100 01/30/2010
UL (TST 1740) ASTM D3161, D7158, D3462 10CA53934 03/31/2011
UL (TST 1740) ASTM D3161, D7158, D3462 11CA48924 10/22/2011
UL (TST 1740) ASTM D3161, D7158, D3462 11CA47919 12/03/2011
UL (TST 1740) ASTM D3161, D7158, D3462 11CA48408 12/08/2011
UL (TST 1740) ASTM D3161, D7158, D3462 11CA48725 12/09/2011
UL, LLC. (TST 9628) ASTM D3462 12CA34891 10/12/2012
UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 12CA58151 02/15/2013
UL, LLC. (TST 9628) ASTM D3161 12CA38083 02/26/2013
UL, LLC. (TST 9628) ASTM D3161 13CA32332 06/18/2013
UL, LLC. (TST 9628) ASTM D3161 13CA37934 08/02/2013
UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4786875675 07/17/2015
UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4787434542 05/17/2016
UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Mobile, AL 12/28/2015
UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Myerstown, PA 02/23/2016
UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Tuscaloosa, AL 02/26/2016
UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Michigan Cty, IN 03/02/2016
UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Shafter, CA 02/18/2016
UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Savannah, GA 02/24/2016
UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Minneapolis, MN 02/09/2016
UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Mt. Vernon, IN 02/09/2016
UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Baltimore, MD 03/01/2016
UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Tampa, FL 02/29/2016
UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Dallas, TX 02/17/2016
UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Ennis, TX 02/03/2016
UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Fontana, CA 03/03/2016
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Marquis® WeatherMax®, Royal Sovereign® and Sentinel® are a fiberglass reinforced 3-tab asphalt roof
shingles.
4.1.2 Camelot®, Camelot® II, Fortitude™, Glenwood™, Grand Canyon®, Grand Sequoia®, Grand Sequoia® IR,
Grand Sequoia® ArmorShield™, Monaco®, Sienna®, Timberline® American Harvest®, Timberline®
ArmorShield™ II, Timberline® Natural Shadow®, Timberline HD®, Timberline® Cool Series®, Timberline Ultra
HD® and Woodland® are fiberglass reinforced, laminated asphalt roof shingles.
4.1.3 Slateline® is a fiberglass reinforced 5-tab asphalt roof shingle.
4.2 Hip & Ridge Shingles:
4.2.1 Seal-A-Ridge® Ridge Cap Shingles, Seal-A-Ridge® IR Impact-Resistant Ridge Cap Shingles, Seal-A-Ridge®
ArmorShield™ Ridge Cap Shingles and Timbertex® Premium Ridge Cap Shingles are fiberglass reinforced, hip
and ridge asphalt roof shingles.
Exterior Research and Design, LLC. Evaluation Report 01506.01.08-R21
Certificate of Authorization #9503 FL10124-R19
Revision 21: 08/26/2016
Page 4 of 6
4.3 Accessory Starter Strips:
4.3.1 Pro-Start® Eave/Rake Starter Strip Shingles and WeatherBlocker™ Premium Eave/Rake Starter Strip Shingles
are starter strips for asphalt roof shingles.
4.3.2 QuickStart® Peel & Stick Starter Roll is a is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS
modified bitumen starter strip, nominal 9-inch x 33 ft roll, for use with asphalt shingles with exposure of 6-
inch or less.
4.3.3 StarterMatch™ Sharter Strip Shingles are color-coordinated starter strips for use with Grand Canyon® and
Grand Sequoia® series asphalt shingles. StarterMatch™ are installed as the second starter for Grand
Canyon® and Grand Sequoia® series installations.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions the reof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing M aterials
Directory for fire ratings of this product.
5.4 Wind Classification:
5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for
use in all wind zones up to Vasd = 150 mph (Vult = 194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 The GAF hip & ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to
Vasd = 150 mph (Vult = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a
mean roof height of 60 feet or less. Calculations by a qualified design professional are required for
conditions outside these limitations. Contact the shingle manufacturer fo r data specific to each shingle.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C. Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be
Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6.2 Starter Shingles or Starter Strip:
6.2.1 Installation of Pro-Start Eave/Rake Starter Strip Shingles, WeatherBlocker Premium Eave/Rake Starter Strip
Shingles and QuickStart Peel & Stick Starter Roll shall comply with the GAF current published instructions.
6.3 Asphalt Shingles:
6.3.1 Installation of asphalt shingles shall comply with the manufacturer’s current published instructions, using
minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following
exceptions:
Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield, and
Woodland require minimum five (5) nails per shingle.
Slateline requires minimum six (6) nails per shingle.
Exterior Research and Design, LLC. Evaluation Report 01506.01.08-R21
Certificate of Authorization #9503 FL10124-R19
Revision 21: 08/26/2016
Page 5 of 6
6.3.2 Fasteners shall be in accordance with manufacturer’s published requirements, but not less than FBC 1507.2.6
or R905.2.5. Staples are not permitted.
6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. Contact the shingle manufacturer for details.
6.4 Hip & Ridge Shingles:
6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles, Seal-A-Ridge IR Impact-Resistant Ridge Cap Shingles and Seal-
A-Ridge ArmorShield Ridge Cap Shingles shall comply with the manufacturer’s current published instructions
with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter
beads of Henkel “Loctite PL S30 Roof & Flashing Sealant”.
6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply with the manufacturer’s current
published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and
beads of Sonneborn NP1 Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant.
6.4.3 Fasteners shall be in accordance with the manufacturer’s published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
Exterior Research and Design, LLC. Evaluation Report 01506.01.08-R21
Certificate of Authorization #9503 FL10124-R19
Revision 21: 08/26/2016
Page 6 of 6
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1 / R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants pr oduce products covered by Florida Rule 61G20-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC – QUA9625; (847) 664-3281
- END OF EVALUATION REPORT -