HomeMy WebLinkAboutWind Load Calculation Property Information Buildinc, InformationInfonation ID Owner: Rick McAninley Wind Zone: 150 MPH. Address: 5949 Clydesdale Ln Exposure Category: C Ft Pierce,F134987 Minimum Building Dimension: 24 ft. Mean Roof Height: 15 ft. Risk Category: IT Design Pressure Calculations ....... O pening r Location Device Devic e Device Fressure ax Positive V; M ax Negative Zone Width(in� Height(in) Elevation(ft) ( s Pressure(psf) 1 End 37 63 2 Int 37 63 7 33.5 -36.5 3 Int 54 83 7 32.1 -35.0 4 Int 106 63 7 31.2 5 End 37 63 7 33.5 -44.2 6 End 26 63 7 34.3 -45.8 7 Int 26 63 7 34.3 -37.3 8 Int 26 26 7 34.6 -37.6 9 End 162 88 7 29.5 -36.0 10 End 384 89 7 26.7 -30.5 11 Int 37 51 7 34.0 -36.9 12 Int 26 26 7 34.6 -37.6 13 Int 37 51 7 34.0 -36.9 Prepared itr accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components acrd Cladding.5th Edition(2014)Florida Building Code. Page I of 1