HomeMy WebLinkAboutWind Load Calculation Property Information Building Information
Owner: Smith Wind Zone: 150 MPH.
Address: 9479 Meadowood Dr Exposure Category: B
Ft Pierce,Fl 34951 Minimum Building Dimension: 24 ft.
Mean Roof Height: 15 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number LZone Width(in) JLHeight(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 75 64 7 26.3 -28.7
2 Int 50 105 7 26.1 -28.6
3 Int 32 41 7 28.5 -31.0
4 Int 54 64 7 26.9 -29.3
5 Int 73 18 7 28.2 -30.6
6 End 120 97 7 24.7 -30.5
7 End 118 98 7 24.7 -30.5
8 Int 129 98 7 24.5 -26.9
9 Int 75 64 7 26.3 -28.7
10 Int 27 64 7 28.2 -30.6
I
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.5th Edition(2014)Florida Building Code.
Page 1 of I