HomeMy WebLinkAboutWind Load Calculation Property Information Building Information Owner: Smith Wind Zone: 150 MPH. Address: 9479 Meadowood Dr Exposure Category: B Ft Pierce,Fl 34951 Minimum Building Dimension: 24 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number LZone Width(in) JLHeight(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 75 64 7 26.3 -28.7 2 Int 50 105 7 26.1 -28.6 3 Int 32 41 7 28.5 -31.0 4 Int 54 64 7 26.9 -29.3 5 Int 73 18 7 28.2 -30.6 6 End 120 97 7 24.7 -30.5 7 End 118 98 7 24.7 -30.5 8 Int 129 98 7 24.5 -26.9 9 Int 75 64 7 26.3 -28.7 10 Int 27 64 7 28.2 -30.6 I Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.5th Edition(2014)Florida Building Code. Page 1 of I