Loading...
HomeMy WebLinkAboutWind Load Calculation Mcastle Impact Windows FACTORY DIRECT SINCE 1969 COMPLETE HURRICANE PROTECTION SOLUTIONS 7089 Hemstreet Place West Palm Beach,FL33413. 800.643.6379 Property Information Building Information Owner: TUCKER,LIZABETH Wind Zone: 165 MPH. Address: 88 Mediterranean Blvd N Exposure Category: D Saint Lucie Gardens Minimum Building Dimension: 37.5 ft. Port Saint Lucie,FL 34952 Mean Roof Height: 15 ft. jot Risk Category: II Design Pressure Calculations Open� LocationIr��eice Device- Device Max Positive IFMax NegativeNumZone h(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 53 54.75 7 41.2 -44.9 2 Int 53 54.75 7 41.2 -44.9 3 Int 53 54.75 7 41.2 -44.9 -------------------------------- ------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------------------------------------- 4 Int 73.25 80 7 39.3 -42.9 ....... - -------------------------------------------------------------------------------------------------------—_-------------------------------------------------------------------- -----------------------— - --—- 5 Int 75 55.25 7 40.2 -43.9 ._...._....__...__..__...._...._-.._.- -..... -------------------------------------------- -----------------------------------..------------------------------------------------------------------------------------------------ - - -- 6 Int 26.5 38.5 7 43.2 -46.9 _......................................_....__.._..................._......................................_._............................._.......................---._..._._........................_..........._..._..-........................--..__...._... -...._._..............._........_._...._... -.................._......_._............--......................._._..............._.............._.._........_............... 7 Int 26.5 38.5 7 43.2 -46.9 JUL I PERWM-TINIG St. Lucie COUnty, FL gum 5 0 P y Prepared in accordance with.ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.51h Edition(2019)Florida Building Code. Page 1 of 1 • Customer: TUCKER,ELIZABETH WorkOrder Number: 06222017013 Unit No. Wall Opening Opening Shutter Shutter Slat Anchor Pressure Width Height Width Height Length Spacing 1 -46.9 53 54.75 68.5 59.75 56.5 9"o.c. 9"o.c. 2 -46.9 53 54.75 68.5 59.75 56.5 9"o.c. 9"o.c. 3 -46.9 53 54.75 68.5 59.75 56.5 9"o.c. 9"o.c. 4 -46.9 73.25 80 88.5 82.5 79.25 9"o.c. 9"o.c. 5 -43.9 74 55.25 89.5 60.25 57 9"o.c. 9"o.c. 6 -46.9 26.5 38.5 40.25 43.5 40.25 9"o.c. 9"o.c. 7 -46.9 26.5 38.5 40.25 43.5 40.25 9"o.c. 9"o.c.