HomeMy WebLinkAboutProduct Approval orida Building Code Online https://www.floridabuilding.orgtpr/pr app_dtl.aspx?param=wGEVX...
1 g
acts'Hotne Log In User Regtstrutbn not lbptcs sutinit surcharge stats&Facts Polikatbns FUG Staff SCIS See Map Links search
Business � 'i - .
�Q eSS14i�c� i ustrodunctscuserowal
l ilii{ duct anntayai•i3gatt[ Sc _14 >ApplrAtbn Detail
_
1'tea r
x_ FL# •FL16048-R3
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer TRI-BUILT Roofing Products
Address/Phone/Email 9054 Louisiana Street
Merrillville,IN 46410
(201)842-2449
david.ruiz@tribuiltmaterialsgroup.com
Authorized Signature David Ruiz
david.ruin@tribuiltmateriaisgroup.com
Technical Representative David Ruiz
Address/Phone/Emalt 250 Route 17 North
East Rutherford,N3 07073
(201)842-2449
david.rulz@tribuiltmateriaisgroup.com
Quality Assurance Representative
Address/ehone{Emall
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC `
Quality Assurance Contract Expiration Date 10/16/2017
Validated By Sohn W.Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL-46q48 pi COI&"-df
Referenced Standard and Year(of Standard) fimftrii Year
ASTM D1970 2009
ASTM G155 2005
FR5A(TRI April 2012(04-12) 2012
TAS 103 1995
I of 2 5/24/2016 9:58 AM
, Y
•orida Building Code Online https://wwwfloiidabuilding.org/pr/pr_app dd.aspx?param=wGEVX...
Equivalence of Product-standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/08/2015
Date Validated 10/19/2015
Date Pending FBC Approval 10/21/2015
Date Approved 12/15/2015
Summary of Products
FL# Model,Number or Name i Description ^�
'16048.1 i TRI-BUILT Roof Underlayments ;Self-adhering,modified bitumen roof underlayments i
limits of Use ;Installation Instructions �Y
Approved for use In HVHZ:No FL36048 R3 II 2015 30 FINAL ER TRI
Approved for use-outside HVHZ:Yes :BUILT UND RLAYMENTS FL16048-R3.pdf
Impact Resistant,N/A Verified By:Robert Nieminen PE-59166
Design Pressure: +N/A/-45 Created by independent Third Party:Yes
t Other:1.)The design pressure noted herein pertains to use Evaluation Reports
;'of foam-on We systems overtop the self-adhering FL16048 R3 AE 2015_.10 FINA(LER iRi-
underlayment for one particular application.See ER Section ;BUILT UNDE tBLLkENT$ FL1 G048-R3 pdf
S,6 for details, 2.)Refer to ER Seaton 5 for other Umits of Created by Independent Third Party:Yes
i Use.
Back �
Cpatact_Us::1940 Horth t4anroe t t Tata asce F 3 3 9 Phone:850-487-1824
The State of Florida Is an A4/EEO employer.�ppyMnt 2oQZ2p1,LSta�r of Fprlda,::Pr vacv Statement:: .pfRv statement::ge _statement
Under Florida law,emal addresses are public records.0 you do not want your e-mal address feleased In response to a public-records request,do not send electronic
-mal to this entity.instead,contact the office by phone or by traditional mai If you have any questions,please contact 850.487.1395.-Pursuant to Section
455.275(1),Fonda Statutes,effective October 1,2012,licensees licensed under Chapter 455.F.S.must provlde the Department with an email address f they have
one.The emacs provided may be used for official communication with the licensee..However emal addresses are public record.U you do not wish tosuppy a
Personal address,please provide the Department wlthan emal address which can be made ava8able to the public.Tb determine If you are a licensee under Chapter
- 455,f S.,please Nick here. -
_ Product Approval Accepts:
.``",— f.rf3
2 of 2 5/24/2016 9:58 AM
EXTERIOR RESEARCH&DESIGN,LLC.
Cert;flcdte of Authorizatl6r;119503
353 CHRISTIAN STREET UNIT#13
TRINI-ff ERD OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Allied Building Products Corp. Evaluation Report A42960.10.12-R3
dba TRI-BUILT Roofing Products FL16048-R3
9050 Louisiana Street Date of Issuance:10/25/2012
Merrillville,IN 46410 Revision 3: 10/08/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials In the State.of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
pro'ducts described herein have been evaluated for compliance with the Sd'.Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION. TRI-BUILT Roof UnderlaVments
LAIIELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation-Report by the named client constitutes agreement,to notify Robert Nierninen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity(ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle. I
ADVERTISEMENT. The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature, if any portion of the Evaluation Report Is displayed,then it shall be done in its entirety.
INSPECTION:Upon request,a copy of this entire Eva'luation Report shall be provided to the user'by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages I through S.
Prepared by:
.01
Sfz
Robert J.M.Nieminen,P.E. shn
Thefac ne seai apwring was authafned 0Y Robert Illemblen.
P.E.cn10J08t20IS.TWsdopsnotseneasanclectronfalysiped
Florida Registration No.59166,Florida DCA ANE1983 document.Signed,seated harcicaoies have been transmirted to the
Product Approval AdminIstraw and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity I ERD does not have, nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing produc%it evaluates.
2. Trinity I ERD i I s not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
1 Robert Nieminen,P.E.does not have nor will acquire,a financial Interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen,P.E, are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unlesssetained
specifically for that purpose.
TRINITYERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: TRI-BUILT Roof Underlayments,as produced by TRI-BUILT,have demonstrated compliance
with the following sections of the Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.4,1507.2.8,1507.2.9.2, Physical,Properties ASTM D1970 2009
1507.4.5.2,1507.5.3,1507.7.3
15�04.6 Accelerated Weathering ASTM G155 2005
1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012
1523.6.5.2.1 Physical Properties TAS 103 1995
3. REFERENCES:
Entity Examination Reference Date
ERD(TST6049) Physical Properties 540540.02.13-1 02/19/2013
ERD(TST6049) Physical Properties 540540.11.13 11/19/2013
ERD(TST6049) Physical Properties 540540.03.14 03/26/2014
ERD(T5T6049) Physical Properties 54870,04.14-2 04/02/2014
ERD(TST6049) Physical Properties S44870.04.14-3 04/02/2014
ERD(TST6049) Physical Properties 544870,04.14-1 04/10/2014
ERD(TST6049) Physical Properties 544870.04.14-4 04110/2014
ERD(TST6049) Physical Properties 543530.02,14-1-RI 05/14/2014
ERD(TST6049) Physical Properties 543530.05.14 05/28/2014
ERD(TST6049) Physical Properties 540540.10.14 10131/2014
ERD(TST6049) Physical Properties SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SC8520.04.15 05/27/2015
UL,LLC.(QUA9625) Quality Control Multiple-Listing R16814 09/04/2015
uL,LLC,(QUA9625) Quality Control Service Confirmation Exp.10/16/2017
4. PRODUCT DESCRIPTION:
4.1 Self-Adheriniz Underlayments:
4.1.1 TO-Bbilt Sand-R.SA,Shingle Underlayment is a self-adhering, glass-mat reinforced, sand-surfaced, SBS
modified bitumen roof underlayment,with a 36-inch sheet width.
4.1.2 Tri-Built S/A HT TU Underlayment is a self-adhering, non-woven polyester fabric surfaced, SBS modified
bitumen roof underlayment
4.1.3 Tri-Built Smooth HT S/A Underlayment is a self-adhering,glass-mat reinforced,film-surfaced,SOS modified
bitumen roof underlayment.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Neminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design,LLC. Evaluation Report A42960.113.12-R3
Cedlfkate ofAuth"Izollon#9503 FL16048-R3
Revision 3:10/0812025
Page 2 of 5
TRI ERD
5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed,a request may be made to the AHI for approval
based on this evaluation combined with supporting data for the prepared roof covering.
5,5 Allowable roof covers applied atop the underlayments are as follows:
TALE 1-• ROOF COVER OPTIONS
Underlayment Asphalt Nall-On Tile 'Foam-On Tile Metal Wood Shakes Slate
Shingles &.Shingles_
Tri-Built Sand RSA Shingle yes No No No Yes Yes
Underlayment
Fri-Built SIN HT TU Yes
Yes Yes Yes Yes Yes
Underlayment See 5.5.1
Tri-Built Smooth HT S/A Yes No. No Yes Yes Yes
Underlayment
5.5.1 "Foam-On Tile" Is limited to use of the following Approved tile adhesives unless tensile adhesion / long
term aging data from an accredited testing laboratory is provided.
i Tri-SuiltS/A HTTU Underlayment with 3M1 2-Component Roof Tile Adhesive A14-160(FL6332)or Dow
TileBondl"Roof Tile Adhesive(FIL717)
5.6 Allowable substrates are noted below:
5.6.1 Direct-Bond to Deck:
Tri Built Sand-R'SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
r Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; ASTM D41 primed structural
concrete.
While not required over plywood,OSB or Southern Yellow Pine substrates,TRI-BUILT recommends priming
the deck if the final roof cover Is not slated for installation within 24 hours. Note: TRI-BUILT requires
tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self-
adhering underlayment.
5.6.2 Bond-to-Insulation:
Tri-Built S/A HT TU Underlayment applied to:
Dens neck Prime;SECUROCK.Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam-on rile systems,insulation attachment shall be designed by a qualified design professional and
installed based on testing of-the insulation/underlayment system in accordance with FM 4474,Appendix D
or TAS 114,Appendix 1.
5.6.3 Bond to Mechanically Attached Base Laver:
y ASTM D226,Type I or Ii felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. for installations under foam-on the systems,base layer shall be attached
per minimum requirements of FRSA/TRI April 2012(04-12).
Exterior Research and Design,LLC_ Evaluation Report A42960.10:12-R3
Cerdfkate 01 Aathadration p9503 FL16048-R3
Revision 3:10108/2015
Page 3 of 5
o�n �m v u
� ���
w �°~�^
5�.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where
the underlayment forms part of the load-path. The following wind uplift limitations apply to direct-deck
undedavmentsystems that are not addressed inFRSA/T8}April 2D12(O4'12),and are used infoam-on tile
applications. Maximum Design Pressure is the result of tesdm; for wind load resistance based on
allowable wind loads,and reflects the ultimate passing pressure divided-by 2(the 2 to 1 margin of safety
per pBC1504.ghas already been app/ied). Refer toFMC16Ogfor determination ofdesign wind pressurws.
5.6.4.1 Maximum Design Pressure=-45.0 ps
'
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional)ASTM D41
Uoderaymmnt* Tri-Built S/AHTTVUwdednymentse|f-adhered'
5.7 ExRosure Limitations:
5'7.1 Tri-Built 5an6-RSAShingle Undedayment orTh8uik Smooth HTS/A Underlavment dbmU not be (eft
exposed for longer than 30'6aysafter installation
5.7.2 Tri-Built S/AHTTUVnder\aymentshall not beleft exposed for longer than 18D'daysafter installation.
G. }msTALmTinm:
� 61 Tm'aU|[r Roof underbymmnt, shall be installed in accordance with TRI-BUILT published installation
'
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
5'2 Re-fasten any loose decking panels,
' andcheck for protruding nail heads. Sweep the substrate thoroughly
to remove any,dust and debris prior to application,and prime the substrate(if applicable).
6,3
'
6.3.1 Shall be installed In compliance with the requirements for ASTM D1970 ondedoyment in FBC Sections
I5V7for the,typovfprepared roof covering tobeinstalled.
6.3.2
' 'Wh&e pdm}o8 Is optional, 'oW|LT recommends priming the deck if the final roof cover is not dated for
installation within 24hours.
Apply sheet parallel tothe roof edge. Roll out approximately 1Vftofmembrane and peel back the first 3
ftcfrelease film.
Adhere the exposed part tothe substrate and unroll the remaining membrane asfar aspossible.
� once the entire length of membrane is in place, pee|'offthe release Mm diagonally' while holding the
membrane tight. Firmly roll the mambranejntoplace tnachieve abond.
Horizontal seams should beminimum 3Finches, configured mmshed water. Vertical seams should be6-
\ochesand staggered not less than 2~ftfrom vertical seams inthe course below. All over-granule end-laps
shall 6esealed using either heat-welding nrhot air welding techniques,
When imxte|UnQ sit slopes above 8:12, Allied Building Products Corp recommends back-nailing in the
overlap area at the too ufthe sheet.at1Z'|ncho.c.
For Valleys and Ridges: Cut uvdedaymentinto 400Gfoot lengths.Peel the release paper and center sheet
`
over valley or ridge. Drape and press sheet into place, working from the center of the valley o,ridge /n
,
each direction. For valleys,apply the sheet starting atthelowest point and work upward.
� 6.3.3 Tile Applications(Tri-Built SIA HT TU Underlayment,only):
�
Reference is made to FRS*/TRI apw| 2013 (04-12) Installation 'Manual and Table I herein, using the
�
instructions noted above asaguideline.
�
Tile shall be loaded and staged In a manner that prevents tile slippage and/or damage to the
undedayment.
^
.
Exterior Research and Design,LLC. Evaluation Report xwu9oo.1o.12-n3
mtUma*ww"m"mramonm9503 r
Revision 3:10/08/2015
Page«pv5
TRIN" ERR
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building official or Authority Having Jurisdiction in orderto properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the noted OA agency for information on product locations covered for F.A.C.Rule 9N-3 QA-requirements.
9. QUALITY AssurtANcE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
END OF EVALUATION REPORT-
Exterior Research and Design,LLC Evaluation Report A42960,10.12-113
Certificate of Authoritattan 99503 F1.16048-113
Revision 3:10108/2015
Page S of S
- r
M
iTlz+e:�.4e 'w f�F-a�,l.A_�' �1'ra:»-.u.•7 '.-,.
BCtS Home Log In User Registratlon Hot Topics j Submit Surcharge Stats 8 Facts Publications j FBC Staff ! BCtS Site Map Links i Search
Florida
' �lr
100
Product Approval
(t• USER:Public User
Product Approval Menu>Product or antHiratian.Search>hnnllcatinn List>Application Detail
FL# FL18355-112
" " a Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer TAMKO Building Products,Inc.
Address/Phone/Email PO Box 1404
Joplin,MO 64802
(417)624-6644 Ext 2305
kerrl_eden@tamko.com
Authorized Signature Kerri Eden
kerri__:eden@tamko.com
Technical Representative
Address/Phone/Email
Quality Assurance.Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation.Report-Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R.Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 01/07/2019
Validated By Locke Bowden
=J Validation Checklist-Hardcopy Received
Certificate of Independence F.1355 R2 COT TBP15001 2 FBC 2Q14 Product Evaluation Report
Shinales.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D 3161 2009
ASTM D 3462 2009
ASTMD D 7158 2008
TAS 100 1995
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method i Option D
Date Submitted 12/16/2015
Date Validated 12/18/2015
Date Pending FBC Approval 12/19/2015
Date Approved 02/10/2016
Date Revised 05/09/2017
Summary of Products
FL# Model,Number or Name Description
18355.1 Glass-Seal,Elite Glass-Seal, ASTM D 3462 asphalt shingles and hip and ridge shingles
Heritage,Heritage Premium,
Heritage Woodgate,Heritage
Vintage,Hip and Ridge,and Vintage
Hip and Ridge.Shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL18355 R2 II TBP15001.2 FBC 2.014 Product Evaluation
Approved for use outside HVHZ:Yes Reoort Shingles.pdf
Impact Resistant:N/A Verified By:Zachary R.Priest PE-74021
Design Pressure:N/A Created by Independent Third Party;Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL18355 R2 AE TBP15001 2 FBC 2014 Product Evaluation
Report Shingles.pg
Created by Independent Third Party:Yes
Beck Pleat
Contact Us::2601 Blair Stene Road.Tallahassee FL 3 399 Phone:850.487-1824
The State of Florida is an AA/EM employer.Copyright 2007-2013 State of Florida ::Privacy statement::Accessibility Statement::Refund Statement
Undcr Florida law,email addresses are public records.If you do not'want your e-mail address released In response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional matt.If you have any questions,please contact850.487.1395.-pursuant to Section 455.275
(1),Florida Statutes,effective October 1,.2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with-an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
click here.
Product Approval.Aeceptsi
I'= H M
Credit Card
Safe
. 1
r
Certificate of Authorization No.29824
CREEK 17520 Edinburgh Dr
Tampa,FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE 5TH EDITION(2014)
Manufacturer: TAMKO BUILDING PRODUCTS Issued December 14,2015
220 West 4h Street
Joplin,MO.64801
(417)624-6644
Manufacturing Plants: Joplin,MO
Phillipsburg,KS
Frederick,MID
Dallas,TX
Tuscaloosa,AL
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category. Roofing
Subcategory: Asphalt Shingles
Code Sections: 1507.2.5. 1507.2.7.1, 1523.6.5.1-
Properties:
523.6.5.1Properties- Physical properties,Wind Resistance,Wind Driven Rain
REFERENCES
Entity Report No. Standard Year
PRI Construction Materials Technologies(TST5878) TAP-043-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-051.02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-054-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-114-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-117-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-130-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-131-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-165-02.01 TAS 100 1995
PRI Construction Materials Technologies,(TST5878) TAP-280-02-01 TAS 100 1995
PRI Construction Materials-Technologies(TST5878) TAP-303-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-307-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-314-02-01 Rev 2 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-315-02-01 ASTM D 6381 2008(2013)e1
PRI Construction Materials Technologies(TST5878) TAP-W7-02-01 TAS 100 1995
UL LLC(TST9628) 02NK9507 ASTM D 3161 2009
UL LLC(TST9628) 04NK24366 ASTM D 3462 2009
UL LLC(TST9628) 05NK28006 ASTM D 6381 2008(2013)e1
UL 2390
ASTM D 7158 2008d
UL LLC(TST9628) 06NK03898 ASTM D 3161 2009
ASTM D 3462 2009
UL LLC(TST9628) 08CA59132 ASTM D 3161 2009
UL LLC(TST9628) 09NK07896 ASTM D 3161 2009
ASTM D 3462 2009
UL LLC(TST9628) I0CA50498 ASTM D 3462 2009
UL LLC(TST9628) I0CA64882 ASTM D 3161 2009
UL LLC(TST9628) IINK14014 ASTM D 3161 2009
ASTM D 3462 2009
UL LLC(TST9628) 12CA24551 ASTM D 3161 2009
UL LLC(TST9628) 4786110543 ASfM'D 6381 2008(2013)e1
UL LLC(TST9628) 47870'43752 ASTM D 3161 2009
UL LLC(TST9628) 4787148748 ASTM D 7158 2008d
ASTM D 3161 2009
ASTM D 3462 2009
TBP15001.2FL18365-R2 Page I of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
TAMKO BUILDING PRODUCTS
CREEK Asphalt Shingles
TscHwAL SERVICES,LLC
PRODUCT DESCRIPTION
Elite Glass-Seat® 12-1/4"x 36",ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab
(Frederick,Joplin& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa) ceramic granules complying with ASTM D 3462.
Glass-Seal 12-114"x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab
(Frederick& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa) ceramic granules complying with ASTM D 3462,
Glass-Seat 12-1/4'x 36',ASTM D 71515, Class H self-sealing, 34ab-asphalt shingle with fiberglass
(Joplin) mat coated,on both sides with asphalt and surfaced with ceramic granules complying
with ASTM D 3462. Shingles shall be used in the non-HVHZ only.
Heritage® 13-1/4" x 39-3/8", ASTM D 3161, Class F- and ASTM D 7158, Class H fiberglass
(Dallas,Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Joplin,Phillipsburg& complying with ASTM D 3462.
Tuscaloosa)
Heritage®Premium 13-1/4" x 39.=3/8", ASTM D 3161. Class F and ASTM D'7158, Class H fiberglass
(Dallas,Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Phillipsburg complying with ASTM D 3462.
Tuscaloosa)
Heritage@ Premium 12" k W, ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Frederick)_ laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage®Vintage@ 17-112"x 40",ASTM D 3161,Class F and ASTM D 7158,Class H fiberglass reinforced,
(Phillipsburg) laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage®
8 Woodgate 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas&Frederick) reinforced, laminated architectural asphalt shingle surfaced with mineral granules
complying with ASTM,D 3462.
Heritage®Woodgate 12" x 36-318", ASTM-D 3161, Class F fiberglass reinforced, laminated architectural
(Frederick) asphalt shingle surfaced With mineral granules,complying with ASTM D 3462. Shingles
shall be used in the non-HVHZ only.
Hip and Ridge Shingles 12-1/4" x 12% ASTM D 3161, 'Class F fiberglass reinforced, hip and ridge asphalt
(Frederick&.Joplin) shingle surfaced with mineral granules complying with ASTM D 3462.
Vintage@).Hipand Ridge 12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle
(Phillipsburg) surfaced with mineral granules complying with ASTM D 3462.
TBP15001.2 FL18355-R2 Page 2 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify GREEK
Technical Services,LLC of any product changes ouquality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
TAMKO BUILDING PRODUCTS
CREEKAsphalt Shingles
TECHNICAL SERVICES, LLC
INSTALLATION
Elite Glass-Seal® Basic Wind Speed(Vwi): Max. 194 mph
(Frederick,Joplin& Basic Wind Speed(V„d): Max. 150 mph
Tuscaloosa) 'Deck(HVHZ): In accordance.with FBC requirements;
& Solidly sheathed min. 19/32 in. plywood or wood.plank for
Glass-Seal new construction; Min. 15732 in. plywood existing
(Frederick,Joplin(Non- construction.
HVHZ)&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction;Min.7/16 in.OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's.application instructions when installing
shingles at slopes greater than 21:12.
Installation(HVHZ): Installed with 5-1/8 inch exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern” detailed
below.
Installation (Non-HVHZ): Installed with 5-118-inch exposure.in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"4 Nail
Pattern"or"6 Nail Pattern"detailed below.
NAILS
Nailing .... .........--- ....... .... ...................-.,-......---.------.........------------.. .- 6-7B"
Area
5-118"
Butt Edlge
Figure 1. Elite Glass-Seal&Glass-Seal
4 Nail Pattern (Non-HVHZ only)
NAILS
.. .. ...._........--........_t/._.................._...... ......L. ._.. 11
Nalhn fi-7l8
Ates9 ..---...._--------_--------- ---------------------.....•_..-----__....----- ....----T.....
. 1
Butt Edge
Figure 2. Elite Glass-Seal&Glass-Seal
6 Nail Pattern
TBP15001.2 FL18355-R2 Page 3 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not
specifically addressed herein.
TAMKO BUILDING PRODUCTS
CREEK Asphalt Shingles
TF-cHNICAL SERVICES,ILLC
Heritage@ Basic Wind Speed(Vol): Max. 194 mph
(Dallas,Frederick,Joplin, Basic Wind Speed(V,-,d)-. Max.150 mph
Phillipsburg&Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements;
& Solidly sheathed min. 19/'32 in. plywood or wood plank for
HeritageO Premium new construction; Min. 15132 in. plywood existing
(Dallas,Frederick construction.
Phillipsburg&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements;
& Solidly sheathed Min. 15/32 in. plywood or wood plank for
Heritage@ Woodgate new construction;Min.7116 in.OSB existing construction.
(Dallas&Frederick) Underlayment: to accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application Instructions when installing
shingles at slopes greater than 21:12.
Installation(HVHZ): Installed with 5-5/8 in. exposure in accordance with RAS
116 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 5-5/8 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either'A Nail
Pattern"or"6 Nail Pattern"detailed below.
FASTENERS NAIL ZONE
COMMON
0/BOND
EXPOSURE 6-6181,
12-1/2-1 12-3/811
Figure 3. Heritage@, Heritage@ Premium,and Heritage@ Woodgate(Dallas)
4 Nail Pattern (non-HVHZ only)
FASTENERSNAIL ZONE
COMMON
BOND
7-1 D
SURE 5-5/8"
Figure 4. Heritage@&Her'Itage0 Premium
6 Nail Pattern
TBP15001.2 FL18355-R2 Page,4 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
TAMKO BUILDING PRODUCTS
CREEKAsphalt Shingles
TECHNICAL SERVICES.LLC
NAIL.ZONE/
11STENERS07 ^—���� COMMON BOND
T
6-if8" EXPOSURE 5 518"
.+
�" �h?-if2=i��-?-if2'i►�+�f-7-3-8" 7-if2�47-if2� �I--�„
Figure 5. Heritage@ Woodgate
6 Nair Pattern
--}i#"'sl"�< 12-f12"---►� �4-- #2-1/2"
,
i
[� Common Bond
FASTENERS i
- �,'.� _'Ci.A1',:;vtr,:::i .hi:•:;r,�`•�r,'�::: ":%`Li':"•�i+:%:F':-:=:;.:t'"�+�it�Y:C:f::• f::".ti•:^:�v`,t.r:•�-.,.;siati
A �
W
N
fl to
i 39=318" �i
Figure 6. Heritage@,Heritage@ Premium, &Heritage@ Woodgate
Alternate 6 Nail Pattern
PAINT
LINE
7-7/9' ZONE
EDGE OF
COMMON
BOND
EXPOSURE
ACCEPTABLE
,-'FASTENER LOCATION
DO NOT FASTEN
ALONG EDGE OF
-- ------ - COMMON BOND
PREFERRED
FASTENER
LOCATION
Figure 7. Heritage@(Tuscaloosa)
Expanded Nail Zone
Nail patterns from Figures 3, 4,and 6 may be placed in the nail zone as described above
TBP15001.2 FL18355-R2 Page 5 of 11 t
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not ?
specifically addressed herein.
TAMKO BUILDING PRODUCTS
C'R E Asphalt Shingles
TECHNICAL SERVICES,LLC
Heritage®Premium Basic Wind-Speed(Vu„): Max.194 mph
(Frederick) Basic Wind Speed(Vasd): Max.150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19132 in. plywood or wood plank for
new construction; Min. 15/32 in: plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min.7/16 in.OSB existing construction.
Underlayment In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12..
installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"4 Nail
Pattern"or"6 Nail Pattern"detailed below.
NAIL ZONEI
FASTENERS �tEEXP
COMMON BOND
51i2° OSURE 5"
12" —► 1-11"--►� �-1„
Figure 8. Heritage®Premium(Frederick)
4 Nail Pattern (non-HVHZ only)
NAIL ZONEI
FASTENERS COMMON BOND
51/2" EXPOSURE 5"
[� Figure 9. Heritage®Premium(Frederick)
6 Nail Pattern
TBP15001.2 FL18355-R2 Page 6 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify-CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
TAMKO BUILDING PRODUCTS
CREEKAsphalt Shingles
TECHiMICAL SERVICES, LLC
Heritage®Woodgate Basic Wind Speed(ViAt): Max. 194 mph
(Frederick) Basic Wind Speed(Vasa): Max. 150 mph
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction;Min.7116 in.OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance.with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"4 Nail
Pattern"or°6 Nail Pattern"detailed below.
NAIL ZONE/
fASTENERS COMMON BOND
T
EXPOSURE V
12-3/8" 11" � �—v
Figure 10. Heritage@)Woodgate(Frederick)
4 Nail Pattern (non-HVHZ only)
NAIL ZOND
FASTENERS COMMON BOND
-' 5'1'2 EXPOSURE 5"
Figure 11. Heritage®Woodgate(Frederick)
6 Nail Pattern
TBP15001.2 FL18355-R2 Page 7 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended.use,or other product attributes that are not
specifically addressed herein.
TAMKO BUILDING PRODUCTS
CREEK Asphalt Shingles
TE:cHNICAL SFRVIC;:S,LLC
Heritage@ Vintage@ Basic Wind Speed(V i): Max. 194 mph
(Phillipsburg) Basic Wind Speed(Vssd): Max, 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in: plywood existing
construction.
Deck(Non-HVHZ): In accordance With FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction;Min.7/16 in.08B existing construction.
Underlayment: In accordance with FSC requirements.
Min.slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115
,.add manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"5 Nail
Pattern"or'6 Nail Pattem"detailed below.
4C'
Fasteners hkiB
fs^
Exposure
Figure.12. Heritage@ Vintage@
5 Nail Pattern (non-HVHZ only)
400
Notch
TFastemm
NOW
17-1ff
rsqwdura
7-
-Yr
Figure 13. Heritage®Vintageo
6 Nail Pattern
TBP15001.2 FL18355-R2 Page 8 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation.r6port does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
TAMKO BUILDING PRODUCTS
CREEKAsphalt Shingles
TECHNICAL SERVICES,LLC
Hip&Ridge Basic Wind Speed(Vat): Max. 194 mph
(Frederick&Joplin) Basic Wind Speed(Vase): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15132 in. plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction;Min,,7/16 in.OSB existing construction.
Underlayment, In accordance with FBC requirements. -
Min.slope: 2:12 and in accordance with FBC requirements.
Installation: Installed with 5-1/8 inch exposure in accordance with the
FBC and manufacturer's published installation instructions.
The direction of the exposed end shall be away from the
prevailing wind.
Direction of prevailing wind
Start 5-1/8" exposure
here1-
Start
Figure 1 here 5-1/8"exposure
its
` Fastener
Fastener
�15�„
„5,5/8"
Figure 2 4 Figure 3
„
Figure 14. Hip &Ridge(Frederick&Joplin)
TSP15001.2 FL18355-R2 Page 9 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not
specifically addressed herein.
TAMKO BUILDING PRODUCTS
CREEK, AsphaltZhIngles
TECHNICAL SERVICES,LLC
Vintage@'Hip&Ridge Basic Wind Speed(Vat): Max.194 mph
(Phillipsburg) Basic Wind Speed(Vasd): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min, 19132.in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck(Non-HVHZ): In accordance with.FBC requirements;
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction;Min.7/16 in.OSB existing construction.
Underlayment: In accordance with FBC requirements.
Win.slope: 2:12 and in accordance with FBC requirements.
Installation: Installed with 5 inch exposure in accordance with the FBC
and manufacturer's published installation instructions. The
direction of the exposed end shall be away from the
prevailing wind.
Direction of prevailing wind
Start 511 exposure
here--
FIn]
n,
Start
here 511 exposure
Figure I
Fa ner astener
5-1/2'
Figure 2 Figure 3
Figure 15. Vintage@ Hip&Ridge (Phillipsburg}
TSP15001.2 FL18355-R2 Page 10 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3- The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
TAMKO BUILDING PRODUCTS
CREEK Asphalt Shingles
TECHNICAL SE2VICE5,LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ.
4) Classificationlo ASTM D-7158 applies to exposure B&C with a building mean roof height of 33-ft or less.
5) Deck substrates shall be clean,dry, and free from any irregularities and debris. All fasteners in the deck
'shall be checked for protrusion and corrected prior to underlayment application.
6) Shingles shall be installed starring at the eave in horizontal layers such that the laps shed water from the
deck.
7) Installation of the,evaluated products shall comply with this report, the FSC, and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and code compliant detail shall prevail.
8) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code 5th Edition(2014)as evidenced in the referenced documents submitted by the named manufacturer.
%% i�N R.
%%% ........
2015.12.14
-A
13:44:19
No 74021
-05'00'
.73 STATE OF
0 R r.-N� 4;- Zachary R.Priest,P.E.
Florida Registraton No.
%
Organization No.iANE964174021
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E.does not have, nor will acquire,a finandal interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
TBP16001.2 FL18355-R2 Page 11 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3- The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,Installation,recommended use,or other product attributes that are not