HomeMy WebLinkAboutBuilding Permit ApplicationALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: 07/27/2017 Permit Number:
• Building Permit Application
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772)462-1553 Fax: (772) 462-1578 Commercial Residential V
PERMIT APPLICATION FOR: To Select from dropbox, click arrow at the end of line
111MD IMPROVEMENT LOCATION:
Address: 619 Paurotis Ln - Fort Pierce, FL 34982
Legal Description: PALM GROVE SID BLK L LOT 17 (0.11 AC) (OR 3390-2416; 3650.1003).
Property Tax ID #; 3410-503-0355-000-5 Lot No. 17
Site Plan Name: Block No. L
Project Name: Water Heater Tank Replacement
Setbacks Front Back: Right Side: Left Side:
DETAILED DESCRIPTION OF WORK:
Replace failed electric water heater tank in garage with new AO Smith 40 gallon tall electric water
heater tank.
CONSTRUCTION INFORMATION:
jj0�diona wor to e e orme under tis -checkpermit a appy
In
JHVAC Gas Tank ❑Gas Piping _Shutters ❑Windows/Doors
I[:
1 (Electric ✓❑_Plumbing ❑Sprinklers Ll Generator ❑Roof Roofpitch
Total Sq. Ft of Construction: Scl��Ft. of First Floor:
Cost of Construction:$ 1500.00 Utilities:) (Sewer❑Septic Building Height:
Name Janet I. Frye Name: Robert W. Ludlum
Address: 619 Paunotis Ln Company: Benjamin Franklin Plumbing
City: Fort Pierce State: FL Address: 1631 SW South Macedo Blvd
Zip Code: 34982 Fax: n/a City: Port St. Lucie State: FL
Phone No. 772-429-2831 Zip Code: 34984 Fax; 772-871-9069
E -Mail: nia Phone No. 772-871-9494
Fill in fee simple Title Holder on next page ( if different E -Mail: permits@benfmnklinplumber.com
from the Owner listed above) State or County License: CFC1426801
If value of construction Is $2500 or more, a RECORDED Notice of Commencement is required.
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION:
FRONT
DESIGNER/ENGINEER:
Name:
Not Applicable
MORTGAGE COMPANY:
Name:
Not Applicable
Address:
MANGROVE
Address:
COUNTER
City:
Zip: Phone:
State:_
City:
Zip: Phone:
State:
FEE SIMPLE TITLE HOLDER:
Name:
_ Not Applicable
BONDING COMPANY:
Name:
_Not Applicable
Address:
Address:
City:
City:
Zip: Phone:
Zip: Phone:
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize the erm it holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or an covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
Inconsideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property. A Notice of Commencement must be recorded an ted on the jobsite
before the first inspectionrJfg6) intend to obtain financing, consult with lenderAran Attorney before
STATE OF FLORIDA � J t o STATE OF FLORIDA
COUNTYOF C"JT.I.GL/'rfL COUNTYOF
The fF.ng instrument was acknowledged before me The forgoing ins
this day of 'ak this qday of
Personally Known Personally Known
Type of Identification r W L N NANDEZ-' Type of IdentiFwtion
;•_ MY COMMISSION 0 GG06NOa nn,,
Commission No. rdPlitgfraynwry 20, 2051 Commission No. 64'
Revised 07/15/2014
acknowledged before me
— 20 & by
1021
REVIEWS
FRONT
ZONING
SUPERVISOR
PLANS
VEGETATION
SEA TURTLE
MANGROVE
COUNTER
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
DATE
COMPLETE
INITIALS
•Smith® Residential Electric
Water Heaters
ENHANCED HEATING ELEMENTS CODE COMPLIANCE
Dual 4500 watt elements for fast recovery in Meets UBC and ICC National Codes and
and reliable operation.* listed with CEC.
• Incoloy stainless steel lower element lasts
longer than a standard copper element.
DYNACLEAN" DIFFUSER DIP TUBE
in Helps reduce lime and sediment buildup
and maximizes hot water output. Made
from long-lasting PEX cross-linked
polymer.
HIGH ENERGY FACTORS
• Eco -friendly non -CFC foam insulation,
heat traps and other features combine
to yield a higher Energy Factor that
maximizes savings on operating casts.
COREGARD"ANODE ROD
• Our anode rods have a stainless steel
core that extends the life of the anode
rod allowing superior tank protection far
longer than standard anode rods.
BLUE DIAMOND" GLASS COATING
• Provides superior corrosion resistance
compared to industry standard glass
lining.
ENHANCED -FLOW BRASS DRAIN VALVE
• Our residential water heaters have a solid
brass, tamper resistant, enhanced -flaw,
ball type, drain valve.
• Uses a standard female hose fitting that
allows for fast and easy draining during
maintenance.
• Designed for easy operation, this valve
includes an integral screwdriver slot that
features a'/e turn (open/close) radius,
which not only permits full straight -
through water flow but also a quick and
positive shut off.
'Model ENL -20 has a single element.
is Complies with the Federal Energy
Conservation Standards effective
April 16, 2015, in accordance with the
Energy Policy and Conservation Act
(EPCA), as amended.
APPROVED FOR MANUFACTURED
HOUSING
• All residential electric water heaters are
compliant with HUD Standards for mobile
hamesfmanufactured housing.
CERTIFIED TO UL 174 FOR HOUSEHOLD
ELECTRIC WATER HEATERS
CSA CERTIFIED AND ASME RATED T&P
RELIEF VALVE
DESIGN -LISTED BY UNDERWRITERS
LABORATORIES
• Certified at 300 psi test pressure and 150
psi working pressure.
• Listed according to UL 174 standards
governing storage tank type electric water
heaters.
6 -YEAR LIMITED TANK AND PARTS
WARRANTY
• For complete information, consult written
warranty or go to hotwateccom.
D efli 2016 A. O. Smith Corti All rights reserved.
awwh..,e[mm 1300-SX?1953 Toll -Free USA I A. 0, smith commission 1500 Tennessee Waite Parkway IAshland Cit,, IN 37015
PERMIT SUBMITTAL DOCUMENTS
SA• UL
AOSPSO.'
(Ce Smith.,
Residential Electric
Water Heaters
Model
Number
Gallo"
Capa<iry
First Nour
Aarin
Gallon
Energy
Fa<tar
Aecove ®
90°F Arse
Gallon Per
Hour
Element watts a 240V
A
Dimensions in Inches
g
C
AppfO"
Shipping
Weight(lgs)
Standard Makimum
Tall Models
ENT30+
30
47
095
21
4500
600
1 d6-1/2
341/2
19
95
ENL401
40
51
0.95
2l
4500
6000
60 1/4
53 1/4
20
118
ENTB 50'
S0
70
0.95
1 21
4500
1 6000
1 60-1/d
1 51-1/4 1
21
1131
ENT 501
50
11
0.95
21
4500
6000
60-1/2
51-I/4
22
134
—ENT 55t
55
]6
094
21
4500
6000
56-12
48-1/2
24
1 145
Short Modell
-
-
-
ENSB-30'
30
48
095
21
4500
6000
39
30.1/2
20
95
fN5-3of
30
49
0.95
21
4500
6000
39314
301/2
22
94
ENS -40f
40
55
0.95
21
4500
6000
50
40-3/4
20-112
109
ENS -501
1 50
62
095
21
4500
1 6000
49-314
1 403/8
23
161
-Lowbov TopConked
Models
ENL -20
19.5
Ni
N/A
21
4500
6000
30
214/420
65
ENLB-30•
28
40
0.95
21
4500
Star
30
21-3/4
22
96
ENL -301
28
43
0.95
21
4500
6000
1 31-14
21-314 11
24
11 115
ENLBA0•
1 38
1 46
0.95
21
4500
1 6000
1 31-314
24 1
24
1 118
ENL -401+
1 38
44
0.95
21
4500
1 6000
1 33-112
24 1
26
1 118
ENLB-50.1
1 48
57
0.95
21
1 4500
1 6000
1 34
25 1
241/2
1 172
Male314'w ne[liwspn8'[mIN.
'aps,Nd h'IP word
insonswblanket.
+fTo loyeanank and6ydea,on his adel[M1ange'E'lo'v"in lM1e model number (example 'ENi 30 becomes INT 30)
r E 20 is option not aeons con on rale mMel.
ENL 20 is a single element [mfgumtion Dory
00onal Tev location #2 is used on the ENT 50, ENTB50, ENT 55, ENS 40 and ENS 50
Top T&P is not awilable m the 10 year modal PNLB3o.
0imeneionaandspeufctows, soba° In shame.1hout nice In aaotdanpe with our pdiq of continuous product indicator
T&P VALVE
ACCESS
PANEL
�- C � B A
ACCESS
PANEL
DRAIN
VALVE
ANODE (OR OPTIONAL
T&P LOCATION #1)
1 OPTIONALT&P
° LOCATION 42
C O ° 0° JUNCTION
BOX
° T&P VALVE