HomeMy WebLinkAboutProduct Approval v ionaa isunamg Loae unlllne rage t or 4
� �:
SCIS Home I Log In I User Registration Hot Topics I Submit Surcharge Stats&Fads Pubfiations i FBC Staff I BaS Shm Map upt. I Search
Florida -
` "¢ Product Approval
_- USER:Public User
r
7.",sold�F:tit
Product Approval Menu>Product or Application Search>Application Lis >Application Detail
° FL# FL14608-116
Appiliation Type Cditmal Change
Code Version 2014
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified
by the POC and/or,the Commission If necessary.
Comments
r Archived Cl
Product Manufacturer Eastern Architectural Systems
Address/Phone/Email 16341 Domestic Ave.
Ft.Myers,FL 33912
(800)432-2204 Ext 4305
jflesher@easternmetal.com
Authorized Signature James Flesher
jflesher@easternmetal.com
Technical Representative Timothy J.Hoard
Address/Phone/Email 10030 Bavaria Road
Fort Myers,FL 33913
(800)432-2204 Ext 4314
thoard@easternmetal.com
Quality Assurance Representative
ft.5.s/Phone/Email
Category Windows
Subcategory Fixed
Compliance Method Certification Mark or Listing
Certification Agency National Accreditation&Management Institute
Validated By National Accreditation&Management Institute
Referenced Standard and Year(of Standard) Standard Year
AAMA/WDMA/CSA 101/I.S.2/A440 2005
AAMA/WDMA/CSA 101/I.S.2/A440 2008
ANSI/AAMA/NWWDA 101/I.S.2 1987
ASTM E1886 2002
ASTM E1886 2005
ASTM E1996 2009
ASTM.E1996 2-002
TAS 201 1994
TAS 202 1994
TAS 203 1994
Equivalence of Product Standards
Certified By
h4.11www.flolidabuilding.Qrg/pr/pr app_dtl.aspx?param=wGEVXQwtDgswgZVNfs8A7... 7/2612017
Florida Building Code Online Page 2 of 4
i'
Product Approval Method Method 1 Option A
Date Submitted 05/24/2017
Date Validated 07/12/2017
Date Pending FBC Approval
Date Approved 07/13/2017
Summary of Products
FL# Model,Number or Name Description
14608.1 Series"1000"Aluminum Non- Series"1000"Aluminum Non-Impact Fixed Window
Impact Fixed Window
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL14608 R6 C CAC NI006122.01-R2-5igned.pdf
Approved for use outside HVHZ:Yes FL34,QQ8..R6 G.AG_.N.j.QQf12, Q,.R.].- ig0.e�,.Rdf
Impact Resistant:No Quality Assurance Contract Expiration Date
Design Pressure: +130.0/-130.0 12/31/2019
Other: Maximum Size: 60"x 48". Monolithic or Insulated Installation Instructions
glass FL14608 R6 II 08-02393A.pdf
Verified By: Luis R. Lomas, P.E.Florida P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL14608 R6 AE 51Q -6._A.pdf
Created by Independent Third Party: Yes
14608.2 Series"1500"Aluminum Non- Series"1500"Aluminum Non-Impact Fixed Window
Impact Fixed Window
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:No FL14,§08 i26.C__GAC„NI006176�OS�R2,- igngd,,pdf
Approved for use outside HVHZ:Yes FL14608 R6 C CAC NI006176.04-111-signed,pdf
Impact Resistant: No Quality Assurance Contract Expiration Date
Design Pressure: +125.0/-125.0 04/30/2020
Other: Maximum Size: 96”x 48". Monolithic or Insulated Installation Instructions
glass FL14608 R6 II 08-02394A.odf
Verified By: Luis R. Lomas, P.E. Florida P.E.62514
Created by Independent Third Party: Yes
Evaluation Reports
FL14608 R6 AE 513167.pdf
Created by Independent Third Party: Yes
14608.3 Series"FWI 2000"Aluminum Series"FWI 2000"Aluminum Impact Fixed Window
Impact Fixed Window
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14608 R6 C CAC NI009023.01-R3-signedpdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 02/28/2021
Design Pressure: +90/-90 Installation Instructions
Other: Maximum Size: 144"x 48" FL14608 R6 II 08-02395A.odf
Verified By: Luis R. Lomas,P.E. Florida P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL146Q8 R6 AE 513168A..p�Jf
FL1460$,_U_AE f�QA,_14=0_4,_2_1¢,PDF
Created by Independent Third Party: Yes
14608.4 Series 1436 Vinyl Non-Impact Fixed Series 1436 Vinyl Non-Impact Fixed Window with Nailing Fin
Window with Nailing Fin
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: NoFL1$�C08 R6 C CAC NI01060 gweed.Pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:No 07/31/2019
Design Pressure: +80/-80 Installation Instructions
Other: Maximum Size: 71 1/2"x 71 1/2". Frame material EL146Q8.R6 II Q>3_QQ.55. C pdf
to be rigid PVC from Deceuninck North America AAMA Verified By: Luis R. Lomas,P.E.Florida P.E.62514
Certified(DEP-1) Created by Independent Third Party: Yes
Evaluation Reports
L1460 R AE1Q,4�6A.pf
Created by Independent Third Party: Yes
14608.5 Series 1446 Vinyl Non-Impact Fixed Series 1446 Vinyl Non-Impact Fixed Window with Flange
Window with Flange
-http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A7... 7/26/2017
Florida Building Code Online Page 3 of 4
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No F"46QQ R6 C -CAC. r(IQ1 6 3-M.&jzsjgned.ndf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 07/31/2019
Design Pressure: +80/-80 Installation Instructions
Other: Maximum Size: 74 1/2"x 72". Frame material to be FL14¢Q8 R6 II Q8 .Q.5
rigid
rigid PVC from Deceuninck North America AAMA Certified Verified By: Luis R. Lomas,P.E. Florida P.E.62514
(DEP-1) Created by Independent Third Party: Yes
Evaluation Reports
EL34608 R6 AE 510948B.Ddf
Created by Independent Third Party: Yes
14608.6 Series 176 Vinyl Impact Fixed Series 176 Vinyl Impact Fixed Window with Flange HVHZ
Window with Flange HVHZ
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL §Q5 _CAG...N.I•Q11878 Q1 R2.,.pdf
1� Approved for use outside HVHZ:Yes FL14608 R6 C CAC N1011878-R2.pd
Impact Resistant:Yes FL14608 R6 C CAC NI011879.01-R2.Ddf
Design Pressure: +80.0/-80.0 FL14608 R6 C CAC NI011879-R2.pdf
(A
Other: Maximum Size: 72"x 63". Frame material to be Quality Assurance Contract Expiration Date
rigid PVC from Deceuninck North America AAMA Certified 01/31/2022
(DEP-1).WHEN INSTALLED IN THE HVHZ THIS PRODUCT IS Installation Instructions
TO BE INSTALLED AT 30'OR LESS ABOVE GROUND LEVEL. 5014, Q.Q_R(._I _,•Q -,Q2,z.Q4B;.p,_f
Verified By: Luis R. Lomas, P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL14608 R6 AE 513043B.pdf
FL14608 R6 AE Kurarary SGP NOA 14-0916.11.PDF
Created by Independent Third Party: Yes
14608.7 Series 176 Vinyl Impact Fixed Series 176 Vinyl Impact Fixed Window with Flange HVHZ
Window with Flange HVHZ
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14608 R6 C'CAC NI011_880 01-R2 Ddf
Approved for use outside HVHZ:Yes FL14608 R6 C CAC NI011880-R2 Ddf
Impact Resistant:Yes FL1460a R6 C CAC NI011881.01-R2Lpdf
Design Pressure: +80.0/-80.0 5114.¢06_ R6 C._..C.9G._.NI,Q,1_l,$81•-. 2p1
Other: Maximum Size: 72"x 84".Frame material to be Quality Assurance Contract Expiration Date
rigid PVC from Deceuninck North America AAMA Certified 01/31/2022
(DEP-1) Installation Instructions
FL14608 R6 II 08-02293B.pd
Verified By: Luis R. Lomas,P.E.62514
Created by Independent Third Party: Yes
Evaluation Reports
FL14608 R6 AE 5130428 Ddf
5114608 R6 AE KurPra.ry—SGP NOA 14 Q916,ll.PDF
Created by Independent Third Party: Yes
14608.8 Series 2456 Vinyl Impact Fixed Series 2456 Vinyl Impact Fixed Window with Nailing Fin
Window with Nailing Fin
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL14608 R6 C CAC NI010610-Rl-signed pdf
Approved for use outside HVHZ:Yes FL14608 R6 C CAC NI010656-R1-signed.Ddf
Impact Resistant:Yes Quality Assurance Contract Expiration Date
Design Pressure: +50/-50 09/30/2019
Other: Maximum Size: 64"x 84". Frame material to be Installation Instructions
rigid PVC from Deceuninck North America AAMA Certified FL14 R6 II 08-OQ$63C.P-df
(DEP-1) Verified By: Luis R. Lomas, P.E. Florida P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL14.4Q8 R6._A_E 51_Q�.�2A:pdf
FL14608 R6 AE NOA 14-0423.15.PDF
Created by Independent Third Party: Yes
14608.9 Series 2466 Vinyl Impact Fixed Series 2466 Vinyl Impact Fixed Window with Flange
Window with Flange
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: NoFL14.508�25 G CAC_NI010(10_Q1^Rjj5jgngd,pdf
Approved for use outside HVHZ:Yes FL14608 R6 C CAC NI010656.01-Rl-signed_pdf
Impact Resistant:Yes Quality Assurance Contract Expiration Date
Design Pressure: +60/-60 09/30/2019
Other: Maximum Size: 64"x 84". Frame material to be Installation Instructions
rigid PVC from Deceuninck North America AAMA Certified FL14608 R6 II 08-00565C.pdf
(DEP-1) Verified By: Luis R. Lomas,P.E. Florida P.E, 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL14608 R6 AE 519`4Bpdf
F.L JA6.Q OL RCLAE_fyQA„_14=0423.15.PD,F
Created by Independent Third Party: Yes
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEV XQwtDgsw8ZVNfe 8 A7... 7/26/2017
j 7 1 I i
REVISIONS ,}
REV DESCRIPTION DATE APPROVED
A REMOVED FLUSH INSTALLATION 07/23/14 R.L.
8 REVISED INSTALLATION DETAILS 065/23/15 R.L.
NOTES: 15. FOR ANCHORING FRAME INTO WOOD FRAMING OR 2X BUCK USE #14 WOOD SCREWS WITH
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH SUFFICIENT LENGTH TO ACHIEVE A 1 7/16" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE
REQUIREMENTS OF THE FLORIDA BUILDING CODE INCLUDING THE HVHZ. ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY 16. FOR ANCHORING FRAME INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT
TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE
RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2"
3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION
4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE DETAILS.
ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED 17. FOR ANCHORING FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS
INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR
MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
18. ALL FASTENERS TO BE CORROSION RESISTANT.
5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY 19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR
FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN
BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM 'STRENGTH SPECIFIED BELOW:
MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. A. WOOD - MINIMUM SPECIFIC GRAVITY OF G=0.42
6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED B. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI.
COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF C. MASONRY - STRENGTH CONFORMANCE TO ASTM C-90, GRADE N. TYPE 1 (OR GREATER).
THE ARCHITECT OR ENGINEER OF RECORD. D. METAL STRUCTURE: STEEL 18GA, 33KSI OR ALUMINUM 6063-T5 1/8" THICK MINIMUM
7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS 20.GEOMETRIC SHAPES ARE ALSO APPROVED_ APPROVED GEOMETRIC SHAPES DIMENSIONS
PROVIDED. SHALL NOT EXCEED INSCRIBED DIMENSIONS OF APPROVED RECTANGULAR ASSEMBLY SHOWN
8. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT IN SHEET 2. GEOMETRIC SHAPES ARE NOT LIMITED TO SHAPES SHOWN HEREIN.
EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR
GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4
9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE
OF SUSTAINING APPLICABLE LOADS.
10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. -
11. FRAME MATERIAL: EXTRUDED RIGID PVC.
12. UNITS MUST BE GLAZED PER ASTM E1300-04, SEE SHEET 2 FOR GLASS OPTIONS.
13. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND
BORNE DEBRIS REGIONS.
14. FOR ANCHORING FIN INTO WOOD FRAMING OR 2X BUCK USE #8 WOOD SCREWS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE
ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
SIGAED:.067/24/2015
EaS`f` FASTERN.iRGIRECMULSYSfENS j�ILtJl1
■ n v n« PMUYEFM nov=a
TABLE OF CONTENTS SERIES 176 PW FIXED WINDOW IMPACT HVHZ 0,; 51, Tt�
72" x 63"
SHEET NO. DESCRIPTION ��
NOTES ��C. 46 TSOF.
1 NOTES DRAWN: DWG NO. REV
2 ELEVATIONS AND GLAZING DETAIL SCALE DATE 08-02294
B ,/17%�Q►�(A„ \�\\
3 - 5 INSTALLATION DETAILS NTS 02/23/14 1 OF 5
REVWNS
REV DESCRIPfgN DATE APPROVED
A REMOVED FLUSH INSTALLATION 07/23/14 R.L.
B REVISED INSTALLATION DETAILS 06/23/15 R.L
73 1/4" MAX TIP TO TIP WIDTH
72" MAX OA WIDTH 72" MAX OA FRAME WIDTH
6" MAX MAX D.C. 6" MAX 2" MAX 12D. .MAX 2• KM
6" MAX
�- 12" MAX
MAX 9 1/2" /
TIP /
TO MAX O.C.
TIP T - /
63" 63"
MAX MAX
o.a A /
HEIGHT / FRAME
HEIGHT
6" MAX
1
SERIES 176 PW FIXED WINDOW SERIES 176 PW FIXED WINDOW
FRAME INSTALLATION EXTERIOR VIEW FIN INSTALLATION EXTERIOR VIEW
DESIGN PRESSURE RATING IMPACT RATING
+80.OPSF LARGE
1• MISSILE IMPACT
1/8" HS MISSILELEVELD,WIND ZONE4 AND HVHZ
3/16" HS .090 SENTRYGLAS BY DUPONT
1/8" HS SIGNED:0612412015
EXTERIOR INTERIOR "" +'+�`i �'"5
GLAZING QUANEx DURASEAL :� Eastern, * • `\\�`S P.Irt10I!/���
BEAD SPACER SYSTEM v: t(',E4S+ "9�-q�/�
2��SaSIKAFLEX
1/2" BITE 552 SERIES 176 PW FIXED WINDOW IMPACT HVHZ �* 0 _
uv 72" x 63" .:
ELEVATIONS AND GLAZING DETAIL hyo 7AT �
�0.
DRAWN: DWG NO. REV i�'cFs.;c1,pR1�4:G�
SETTING BLOCK GLAZING DETAIL .LL 08 5027294 8 ✓<77S�pNA l`�\\�
NTS �� 02/23/14 2 OF 5
5/8" MIN. REVISIONS
EDGE DISTANCE EDGE DISTANCE 1" MIN. REV DESCRIPTION DATE APPROVED
WOOD FRAMING METAL A REMOVED FLUSH INSTALLATION 07/23/14 R.L.
OR 2X BUCKSTRUCTURE
B REVISED INSTALLATION DETAILS 06/23/15 R.L.
BY OTHERS 1 7/16" MIN. BY OTHERS
EMBEDMENT rol I------—
METAL 11/4" MAX.
STRUCTURE SHIM SPACE
ff1��FyI
(} 1/4" MAX. BY OTHERS
APPROVED °UU� 1/4" MAX. �-° SHIM SPACE #10 SMS OR
SEALANT SHIM SPACE
BEHIND FLANGE APPROVED SELF DRILLING O
SEALANT SCREWS °
BEHIND FLANGE #14 SMS OR INTERIOR
#14 WOOD SELF DRILLING °
SCREW SCREW 1" MIN.
EDGE DISTANCE a�Q
APPROVED EXTERIOR
SEALANT
BEHIND FLANGE JAMB INSTALLATION DETAIL
INTERIOR EXTERIOR INTERIOR METAL STRUCTURE INSTALLATION
EXTERIOR 1 7/16" MIN.
EMBEDMENT 1/4" MAX.
#14 WOOD SHIM SPACE
SCREW
5/8" MIN. /7 �0
EDGE DISTANCE o
Q
�_ ° INTERIOR
#14 SMS OR
APPROVED SELF DRILLING #14 WOOD
APPROVED SEALANT SCREW SCREW Q
n11 -/A
" W BEHIND FLANGE
BEHINDSEALANT
° MAX FRAMING
FLANGE ° I Ia0 SHIM SPACE METAL ° SHIM SPACE OR 2X BUCK u
U STRUCTURE BY OTHERS
WOOD FRAMING t BY OTHERS EXTERIOR
OR 2X BUCK 1 7/16" MIN APPROVED
BY OTHERS SEALANT JAMB INSTALLATION DETAIL
EMBEDMENT BEHIND FLANGE
WOOD FRAM/NGOR 2X BUCK INSTALLATION
1" MIN.
5/8" MIN. EDGE DISTANCE SIGNED 06/24/2015
EDGE DISTANCE ens w,.no sc wKs arcus
VERTICAL CROSS SECTION VERTICAL CROSS SECTION a�4 Eastern � � \ g R I IL p �ii�
WOODFRAM/NGOR2XBUCK/NSTALLATION METAL STRUCTURE INSTALLATION e.. - �e�m.��oo,�s'rcAVE �,
Eom urcAs.noaoA r�,v�tfilVs •'�S•��
SERIES 176 PW FIXED WINDOW IMPACT HVHZ AkFP04F-M'!,k,
NOTES: 72" x 63"1.INTERIOR ANDEXTER10RF1NISHES,BYOTNERS, FLANGE INSTALLATION DETAILS ��0
NOT SHOWN FOR CLARITY. owcNo2.PERIMETER AND JOINTSEALANT BY 18STOBE REV
OSIGNEDINACCORDANCEWITHASTME21JL 08-02294 0�..��. A••,�k!`�
i�/FSS NAA
SCALE NTS DATE 02/23/14 SHEETS OF 5 ///�QNAi, ��\�
2 1/2" MIN. REVISIONS ^
EDGE DISTANCE REV DESCRIPTION DATE APPROVED
CONCRETE/MASONRY A REMOVED FLUSH INSTALLATION 07/23/14 R.L.
BY OTHERS a e REVISED INSTALLATION DETAILS 06/23/15 R.L.
a'
a 1 1/4" MIN.
OPTIONAL 1X BUCK ` " 'd. ••a EMBEDMENT
SEE NOTES 3-7 SHEET 1 1 1/4" MIN
0 , } EMBEDMENT
CONCRETE/MASONRY
APPROVED
❑ 1/4" MAX. BY OTHERS
SEALANT OPTIONAL 1X BUCK SHIM SPACE °v 1/4" MAX.
SHIM SPACE
BEHIND FLANGE rf7l SEE NOTES 3-7 SHEET 1 °
U 3/16" TAPCON 3/16" TAPCON a
INTERIOR
c
El
2 1/2"MIN.
a veau
EXTERIOR INTERIOR EDGE o 0
DISTANCE
APPROVED
SEALANT EXTERIOR
BEHIND FLANGE
3/16" TAPCON JAMB INSTALLATION DETAIL
n CONCRETEIMASONRY INSTALLATION
APPROVED �J
SEALANT
BEHIND FLANGE1/4"
vU
OPTIONAL 1X BUCK o SHIM
MAX.
SPACE NOTES:
SEE NOTES 3-7 SHEET 1 �p 1.INTERIORAND EXTERIOR FINISHES,BYOTHERS,
NOT SHOWN FOR CLARITY
0 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE
CONCRETE/MASONRY _� DESIGNED IN ACCORDANCE WITH ASTM E2112
'.° • SIGNED:06/24/2015
BY OTHERS
• n
a 1 1/4" MIN. *�+ +�^^�+ �ttlllllj
• • = Eastern ADNSONOF \.`g•R co z
a� EMBEDMENT F,vSrwauET.0 svcir 7
a
<•
2 1/2" MIN. SERIES 176 PW FIXED WINDOW IMPACT HVHZ
72' x 63"
EDGE DISTANCE FLANGE INSTALLATION DETAILS ¢f� TAT OF t4.
SCALE NTS DATEowNO.CICROSS
L 0+1RtttECO RETEMASOY/NSTALAO j 08-02294 S/O ,1102/23/14 SHEET4 OF
`\
5
REVISIONS
-- I
REV DESCRIPTION DATE APPROVED
A REMOVED FLUSH INSTALLATION 07/23/14 R.L.
8 REVISED INSTALLATION DETAILS 06/23/15 R.L.
APPROVED
SEALANT
BEHIND FIN 1 1/4" MIN.
EMBEDMENT
#8 WOOD WOOD
SCREW FRAMING
BY OTHERS
1/4" MAX. WOOD FRAMING .{ 1/4" MAX
F SHIM SPACE BY OTHERS I SHIM SPACE
7/16" MIN
EDGE DISTANCE
INTERIOR
� o0
1 1/4"
MIN.
EMBEDMENT
EXTERIOR INTERIOR
�Q
#8 WOOD
SCREW
APPROVED
SEALANT EXTERIOR
BEHIND FIN 7/16" MIN
EDGE DISTANCE
JAMB INSTALLATION DETAIL
WOOD FRAMING OR 2X BUCK INSTALLATION
1/4" MAX NOTES:
SHIM SPACE 1.INTERIOR AND EXTERIOR FINISHES,BYOTHERS,
NOT SHOWN FOR CLARITY.
2.PERIMETER AND JOINT SEALANT BYOTHERS TO BE
7/16" MIN j DESIGNED INACCORDANCEW/7HASTME2112
EDGE DISTANCE
#8 WOOD WOOD SIGNED:05/24/2015
SCREW FRAMING
APPROVED EM EDMENT BY OTHERS EaStel`I1 \�\��S
10114
VERTICAL CROSS SECTION .,
SEALANT A,,,,,a.',',•„y�'�` •^"' 'i-oRrurrns.no-m=2
BEHIND FIN WOOD FRAMING OR 2X SUCK INSTALLATION SERIES 176 PW FIXED WINDOW IMPACT HVHZ Z_ o $T
72" x 63"
FW INSTALLATION DETAILS =p ?OF
DRAWN: DWG NO. REV �F!�1OR��4`:.: \
SCALE Dare 08 02294 8 NAL
NTS 02/23/14 1 SHEET 5 OF 5
M.
SCIS Iiome iogdn ( UserReoswa ipn IictTopics Sut;e*surchaMe Stats&Facts %br=uDns pBc Soff .005 site Map i Unks � Search
F! dda
Product Approval
sA BSER:public User
d,
` Product Approval Menu>Rroduct or Application search>Application List>Appitcation Detail
REMFL# FL16412-112
Application Type Revision
Code Version 2014
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission If necessary.
Comments
Archived
Product Manufacturer Eastern Architectural Systems
Address/Phone/Email 16341 Domestic Ave.
Ft.Myers,FL 33912
(800)432-2204 Ext 4305
jflesher@eastemmetal.com
Authorized Signature James Flesher
jflesher@easternmetai.com
Technical Representative Timothy J.Hoard
Address/Phone/Emali 10030 Bavaria Road
Fort Myers,FL 33913
(800)432.2204 Ext 4314
thoard@easternmetal,com
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Single Hung
Compliance Method Certification Mark or Listing
Certification Agency National Accreditation&Management Institute
Validated By National Accreditation&Management Institute
Referenced Standard and Year(of Standard) StandaEd Year
AAMA/WDMA/CSA 101/I.S,2/A440 2005
AAMA/WDMA/CSA 101/I.S.2/A440 2008
ASTM E 1886 2005
ASTM E1996 2005
ASTM E 1996 2009
TAS201 1994
TAS202 1994
TAS203 1994
Equivalence of Product Standards
Certified By
hq-//wIrv.floriclabuilding..arg/pr/pir app_dtLasFx?garam=WGF,VXQWtDgVXaHHDWAAyb.6.gTr-iQEQV.doF%2.,. 6/7/2.017
1 ar'G 4 V1 4
Product Approval Method Method 1 Option A
Date Submitted 09/28/2016
Date Validated 09/29/201,
Date Pending FOC Approval
Date Approved 10/02/2016
Summary of Products
FL# Model,Number or Name Description
16412.1 176 Vinyl Impact Single Hung 176 Vinyl Impact Single Hung
L colts of Use Certification Agency Certifscate
Approved for use in HVHZ:Yes FL16412 R2 C CAC NI012195 odf
Approved for use-outside HVHZ:Yes Quality Assurance Contract•Expiration Date
Impact Resistant:Yes 06/30/2018
\� Design Pressure:N/A installation Instructions
\ other:Design Pressures are as follows:Fln Window FL16412 R2 fi 08-02538A.pdf
0 +70.0/-85.0psf,Flange Window+70.0/-85.0psf.Maximum Verified By:Louis R.Lomas,P.E.62514
Size:54"x 77".Frame•Material.to be Rigid-PVC From Created by Independent Third Party:Yes
Deceuninck North America AAMA Certified(DEP-1) Evaluation Reports
FL16412 R2 AE 13-0328 09-COMP odf
FL16412 R2 AE 13-0328.09 Dupont SentryGlas odf
FL16412 R2 AE 513311A.odf
Created by Independent Third Party:Yes
16412.2 Series HD2451/Series.HD2461 Series.HDZ451/Ser1es.HDZ461 Vinyl Impact Single.Hung
Single Hung
Limits of Use Certification Agency Certificate
Approved for use In HVHZ:No FL16412 R2 C CAC NI01153 -Rl-signed.pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 09/30/2018
Design Pressure:+65.0/-65.0 Installation Instructions
otl1w.:Maximum Size:44".x 84",Nailing fin or Flange Frame. FL16412 R2 11 08-01933A.pdf
Frame Material to be Rigid PVC From Deceuninck North Verified By:Luis R.Lomas,P.E.62514
America AAMA Certified(DEP-1) Created by Independent Third Party:Yes
Evaluation Reports
FL16412 R2EtE-512641A odf
FL16412 R2 AE NOA Safiex PVB 15-1201.11.pdf
Created by Independent Third Party:Yes
Back Next
Contact U, g1 Blair Stone kgad,Talla pssee,[L 3 399 Phone:850.467.1824
The State of Florida Is an WEED employer.Copyright 2007-2013,State of Florida ::Privacy Statement::gcessiblii Statement::Refund Statement
Under Florida law,emall addresses are public records.If you do not want your e-mail address released in response to a publlc-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mail.if you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
dick here.
ArAdu.,�ctAPPMAi Acs PW
IN 9
Credit Card
Safe
MEN=
http://www.floridabuikling.org/prlpx�_appMI.. 617/2037
REVISIONS
REV DESCRIPTION I 0.Tc APPROVED
ARE`/ISEO IN57ALLAION OETAII.S 06/23;'75 R.L. -
NOTES: 15. FOR FRAME ANCHORING INTO WOOD FRAMING: OR 2X BUCK USE 410 WOOD SCREWS WITH
1. THE PRODUCT SHOWN HERE.N IS DESIGNED AND MANUFACTURED TO COWILY.•'WITH
REOUiREMEMS OF THE FLORIDA SUFFICIENT LENGTH TO ACHIEVE A 1 1/4 MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE
BUILDING CODE INCLUDING THE HVHZ. ANCHORS AS SHO:JN IN'ELEVATIONS AND INSTALLATION DETAILS.
2. WOOD FRAMING AND MASONRY' OPENING TO 8E DESIGNED AND ANCHORED'-TI4E,PROPERLY 16 TOR FRAM^ ANCHORING INTO MASONRY CONCRETE USE 3 :6" TAPCONS WITH SUFFICIENT
TRANSFER ALL LOADS TO STRUCTURE- FRAMING AND MASONRY OPENING iS.'THE. /
RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF'RECC+RD. LENGTH T0.ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2"
3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION
4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS.MUST BE DETAILS.
ANCHORED.THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED 17. FOR FRAME ANCHORING INTO MEAL -STRUCTURE USE 111.0 SMS OR SELF DRILLING SCREWS
INSTALLATION INSTRUCTIONS. ANOHGRS,SHALL BE SECURELY FASTENED DIRECTLY INTO WITH SUFFICIENT LENGTH T0,ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR
MASONRY, CONCRETE OR OTHER STRUCTURAL.SUBSTRATE MATERIAL WALL LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
5 18. ALL FASTENERS TO BE CORROSION RESISTANT-
WHERE WOOD BUCK THICKNESS IS 1—i/2- OR GREATER, BUCK SHALL BE SECURELY 19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCOPIANC€ `WTH ANCHOR
FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS \JAY MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL. NOT BE USED IN
BE ANCHORED THROUGH FRAME TO SECURED WOOD'BUCK IN ACCORDANCE WITH SUBSTRATES WITH STRENGTHS LESS THAN THE /;INIr%UM STRENGTH SPECIFIED BELOW:
MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. A WOOD — MINIMUM SPECIFIC, GRAVITY OF C=0.42
6. WHERE TX BUCK IS NOT U_=.ED (DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROvED B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH 07 3.132 PSI.
COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF C. MASONRY-- STRENGTH CONFORMANCE TO ASTM C-90, GRADE N. TYPE 1 fOR GREATER).
THE ARCHITECT OR ENGINEER OF RECORD. D. METAL STRUCTURE: STEEL 'SGA. 33<SI OR ALUMINUM 3053—T5 1/8" THICK :dINl1 UEJ
7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS 20.UNITS MAY BE INSTALLED WITH OR WITHOUT FLAN:X OUTSIDE THE H-HZ-
PROVIDED.
E. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM, AS REQUIRED AT
EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/15' LIR
GREATER OCCURS. MAXIMUM ALL•rWABLE SHIM STACK TO BE 1/4".
9. SHIMS SHALL BE LOCATCO, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLL
OF SUSTAINING APPLICABLE LOADS.
10. WINO LOAD DURATION ':ACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS.
11. FRAME MATERIAL: EXTRUDED RIGID FVC.
12. UNITS MUST BE GLAZED PIER ASTM E1300-04, SEE SHEET 2 FOR CLASS OPTIONS.
13. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND
BORNE DEBRIS ;REGIONS.
14. FOR FIN INSTALLATION INTO •`.FOOD FRAMING OR 2X BUCK USE j10 WOOD SCREWS '1JITH _
.SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE
ANCHORS AS SHOWN 114 ELEIVATiONS AND INSTALLATION DETAILS.
SIGNED.06/2.412015
Eastern `,�,`�R. r p z
�., .�
' GENS.
TABLE OF CONTENTS 176 SH VINYL SINGLE HUNG WINDOW *� 0 7
SHEET NO. DESCRIPTION IMPACT 54" X 77"
NOTES 7D'' S7�1T�OF
NOTES
ELEVAlFIONS
"Ev
4 — 7 INSTALLATION DETat S ` NTS -'c 11/17/14 08-02538 1 OF 7 A
54" MAX FRAM: WIDTH . REVISIONS
REV DESCRIPTION. mTE APPROVED
6" 1+1 X MAX 4O.C. 6" MAX A R-MSEC INSTALLAON DETAILS b6J23/i5 R.L.
6 MAX
OHARDWARESCHEDULE
13" /
MAX O.C. A. (4)ASHLAND DUAL KEEPERS(13959).ATXEEPERRAIL&'FROM EACH JAMB
/
B. (4)ASHLAND DUALLOCKS(D1100AL/R)AT KEEPER RAIL 8-FROM EACH JAMB
C. (2)CALDWELL COIL BALANCESYSfEM(880)ONE ATEACH JAMB
77 D. (2)CALDWELLTILT LATCH(20000p41)11%2"FROM EACH SASH TOP RAIL CORNER
FRPdE (— E (2)CALDWELL PIVOT BAR(16VS13)ONEATEACH END OFOPERABLE SASH BOTTOM RAIL '
HEIGHT
1/8" ANN.
I
.090" SENTRYGL;:S BY DUPONT3!16" ANr!. li&" aNN.
/ GLAZING BEAD—\ - DuP.A—SEAL
/ I SPACER SYSTEM.
6 MAX /�j
-- ^
INTI=RIOR .
EXTERIOR l'I'
SIKP.FLEX 552
SERIES 176 SH_VINYL SINGLE HUNG WINDOW SETTING BLOCK SEALANT
EMRIOR VIEW GLAZING DETAIL
FIN INSTALLATION
DESIGN PRESSURE RATI111G IMPACT R477NG
+70.01-85.OPSF LARGE
MISSILE IMPACT
MISSILE LEVEL D,WIND ZONE 4 AND HVHZ
SfGNED_06/24/2015
FATTE1tN MC"R EC fu1GL SYSiFAg
��� A OmaonoE ��l
Eastern ��NE,K�n. ,.��s R- oNOTES: '�%,
1. MAXIMUM SASH SIZE. 50 3/8" X 37 3/4•. ,�:�.".._." "�..... �. eoo.a�nAVE. .`�\`JEIVq
.s.....,...:..wo vo wv� 1-1 urERS.natmA3lGu. j
2. MAXIMUM D.L.O.: 49 1/8" X 34 3%4". SERIES 176 SH VINYL SINGLE HUNG WINDOW �yr�'�1
3. (2) WEEPS WITH COVER (47—G3) AT SILL FACE 2" FF.OM EFa=H CORNER. IMPACT 54" X 77" '
4 (2) I 1/2" X 1/4" Y'EEP SLOT AT SILL PACE 2" FROM EACs. CORNER. ELEVATIONS �- .��
��. TATE OF
5. (2) 1/2 X 1/8" WEEP SLOT AT SILL BEHIND GLI A21NJ LEG. �0.
oRAv,,; eecNo. Rev �iF C01WOP.���.
SG'•:E NTS DANE 11/17/14 08-025280E 7 A i/NAj1��G` ��
P
. RFVFJONS
. .. REV OESCRIP.,TI:r. DATE AMMIED .:.
54- MA)e FRAME WIDTH A REVISED INSTALAT104 bETMLS I Do/23ji5 R.L.
54 MAX FRAME S11DTH ---'----------
f4 10"
o' MAX MAX O.C. r 6" MAX 6 MAX MAX 6" MAX
6: MAX o" MAX
,y11aX�0.�. ..0 :5"
Mt O.C.
774' / 77"
MAX __ MAY..
FRAME FRAME,
HEIGHT I HEfGHT i
i 1
6" MAY
5" MAX
t-
SERIES 176 SH VINYL SINGLE HUNG WINDOW SERIES 176 SH VINYL SINGLE HUNG WINDOW
EXTERIOR VIEW EXTERIOR VIEW
THROUGH FRAME INSTALLATION THROUGH FRAME INSTALLATION
FOR MASONRYAND METAL STRUCTURE FOR WOOD FRAMING
DESIGN PRESSURE RATING IMPACT RATING
+70.01-85 OPSF LARGE
MISSILE IMPACT
MISSILE LEVEL D.IN/ND ZONE 4 AND HVHZ SIGNED.06/24MO 15
ewsrEraJwaarcerurK srsreJAs ````S to
o�//'
� /i
►' wom9anor RC1. fI!
�- Eastern , �YK
n�•L•:d 'ro'aiurE�Rs'n�oR�a
SERIES 176 SH VINYL SINGLE HUNG WINDOW _fir• p. yt=
IMPACT SI TAT OF
X 77" =,o'�G
ELEVATIONS �o_
DRAWN: GYJj NO. kEV ��••��Z� -`
N.G. 08-02538 A �Rt� G;`��
SCALE NTS -E 11/17/14 1$"'L 3 OF 7
REMSONS
ONS
1/2" MIN. RV DESCRIPTION ' MTE nPPRG�EU
-r�EDGE DISTANCE A REVISED INSTALLATION DETAILS 06/23)
WOOD FRAMING �------
OR 2X BUCK
BY OTHERS 1 1./47 MIN.
EMBEDMENT
it
BACKER RODdO�n
&
APPROVED SHIM.SPACE 1 1/4" Fd;N. i/4" MAX.
SEALANTIL �F,tBEGM=NT SHIM SPACE '
i
g rI I . iy INTERIOR
0 WOOD SCRE
L 5 j2" tr11M.
EDGE DISTANCE 1 OHO
EXTERIOR i + i
I n
0 ViO0; 1 0
SCREsv / j 1
I ;FOOD FRAMING
OR 2X BUCK �c
INTERIOR BY OTHERS G�
II' I!I
L SACKER ROD EXTERIOR
I ( & APPROVED
SEALANT
i JAMB INSTALLATION DETAIL
D WOOD FRAMING OR 2X BUCK INSTALLA77ON
Ii
I ( of SILL TO BE SET
IW A BED OF
�� APPROVED SEALANT
BACKER RODL `.
& APPROVED I 1/4" MAX.
SEALANT 1 I , SHIM SPACE -
WOOD FRAMING
OR 2X BUCK
BY OTHERS
SIGNED.06/24/2015
VERTICAL CROSS SECTION
WOOD FRAMING OR 2X BUCK INSTALLA77ON lie A— o
R"4 X 9
NOTES:
SERIES 176 SH VINYL SINGLE HUNG WINDOW 1.INTERIOR AND EXTERIOR FINISHES.BYO7HERS, IMPACT 54" X 77"INSTALLATION DETAILS
NOT SHOWN FOR CLARITY. �P. TAT OF
�O
2.PERIMETER AND JOINT SEALANT BYO7HERS TO BE DaFwv. D.,r.��• RLy i'.c�..c(ORI�P•\�\`
DESIGNED INACCORDANCE WITH ASTM E2112 N.G. 08-02538 A TSS
Sc4tE NTS UnTM 11/17/14 S11EET4 OF 7
r
F— VA MIN, rtEv CES "p-N. OrTE VaROVED
METAL i EDGE DISTANCE
' I —r.' A -REVISEC WSTALU+TION DETAILS L06%23115 R.L.
STRUCTURE —•
BY OTHERS 1/4" MAX.
SHIM..SPACE
APPROVED' L1Ca
SEALANT to
J� #10: SMS OR .
U' SELF DRILLING
SCREW 1/4" MAX.
—j SHIM SPACE
I. I INTERIOR
EDGEDISTANCE
J
5 I R1(1'SMS OR 1
R SELF'DRILLING I ��--
[� SCREWS
EXTERIOR a i INTERIOR METAL
i
I
BYOTHERSi G
• BACKER ROD -1 EXTERIOR
i & APPROVED
II r SEALANT
n iH i u SILL TO� BE SET A BEG OF
IQ I APPROVED SEALANT JAMB INSTALLATION DETAIL
PJCKEP. ROD t METAL STRUCTURE INSTALLATION
APPROVED L
SEALANT — a '1/4' MAX.
SHIM SPACE
METAL (� t
STRUCTURE
BY OTHERS
VERTICAL CROSS SECTION
METAL STRUCTURE INSTALLATION
SIGNED.06/24/2015
FASfERNaRCM1ECTUILILSYLiEaG �1lfllflly'
- Eos ern °^ K .��5 R. i o zCAW �
ioar urEas.aomm�avtt `r�•'�C.E N'S. cS'��
.t�'�'""^ ero.aaa V Ll".
NOTES: SERIES 176 SH VINYL SINGLE HUNG WINDOW *' MOF-m
1.INTERIOR AND EXTERIOR FINISHES. IMPACT 54" X 77"
BYOTHERS,NOTSHOWN FOR CLARITY. INSTALLATION DETAILS S ��t�=
DESIGNED IN ACCORD2.PERIMETER AND ANCE WITH ASTM E21NT BY OTHERS TO BE G.: ^, REQ/ ��j��:cLOR10P G
scyE oar OS-OE538 A ��/;YONA`l��
NTS 11/17/14 5 OF 7
i CONCRETE/IdASONRY REASONS
_I 2 1/2" MIN. BY OTHERS REV DESCRIeTIGN. I DATE APPROVED
EDGE DISTANCE
A REVISEQ INSTALLATION�DETNLS* 0E/23/15 R.L.
°
e 1 i/4" MIN.
EMBEDMENT
EMBEDMENT ' I
CONCRETE/MASON.RY
OPTIONAL 1X BUCK Jo �Do BY OTHERS '
SEE NOTES 3 — 7 O 1/a" MAX. "
SHEET 1 j SHIM SPACE OPTIONAL 1X BUCK ! —� t/4" MA<.
SEE NOTES 3 - 7 I' I I SHIM SPACE
uISHEET,1 ,
3/10" TAPCON
SACKER ROD—� 3/16" TAPCON
&
APPROVED !
SEALANT I i � i INTERIOR..
� f
� t DOLS
INTERIOR
EXTERIOR I j 1IF
I MIN. ; 1 !
EDGE
I � DISTANCE
a�J EXTERIOR
Hi !
BACKER ROD—/
SACKER ROD f I ! & APPROVED
o"c APPROVED I SEALANT JAMB INSTALLATION DETAIL
SEALANT i` l i 'r; CONCRETFIMASONRYINSTALLATION
_ _ D SILL TO BE S
IN A BED OF
APPROVED SEALANT
114" MAX. NOTES:
OPTIONAL 1X BUCK I r SHIM SPACE 1.1NTERIORANDSGERIORFINISHES.BYOTHERS,
SEE NOTE NOTSHOWNFORCLARRY.
SHEET 1 Q 2.PERIMETERAND JOINTSEALANTBY OTHERS TO BE
DESIGNED 1N ACCORDANCE WITH ASTM E2112
—�� SIGNED:06/24/2075
I•. w e e •a u e
T
Ow
f/3TERNNKwECfufuLSISTEMt �;{II11!
1 Eastern s° . s :t""vw":=-li.v000—.� FO�AfWE�S RAowa z> ] ..�`�£Ns 9s�ii
SERIES 176 SH VINYL SINGLE HUNG WINDOW
\ IMPACT 54." X 77" — —
\ INSTALLATION DETAILS p:
OTA7' OF
CONCRETE/}AASONRY D;KWN: am0NOS SECTION . 'cC.ORidP•.���� '
CONRCRETEIMASOTICAL ORYINSTALLATION BY OTHERS N.G.
NTS D"TE 11/17/14 08-025385260E 7 A /''�ssV�NA11��G\\\\ .
r"
g
. REV60N5
1 1/4"'MIN.
REL'
EMBEDMENTOES: W-h RIPTION. NPROVM
SEdLAN7 � ' ,
BEHMD FIN \ WOOD A RE nSED WSTALLATIN DETARS 06/23]t5. R.L,
FRAMING`
#10.W000 BY OTHERS
SCREW 1
144 MAX.
1:/2" MIN
SHIM SPACE
EDGE DISTANCE
W006 FMING —1 1/4 MAX
RA
BY OTHERS� I �SHIM SPACE
INTERIOR
Y
1 1/4- L OO
I MIN. l ! rl]. _
EXTERIOR I L INTERIOR EMBEDMENT
I j #10 WOOD
SCREW j
APPROVED -� 1:'2 MIN EXTERIOR
SL4>ANT -DGE DISTANCE
BEHIND FIN
I JAMB INSTALLATION DETAIL
WOOD FRAMING OR2XBUCKINSTALLATION
0
1/4- MAX_ NOTES:
1�!J 5'r.11f: SPACE T.INTERIOR AND EXTERIOR FINISHES.BYOTHERS.
i
j NOT SHOWN FOR CLARITY.
2.PERIMETER ANDJOWT SEALANT BY OTHERS TO BE
I/2" tJIN �, DESIGNED INACCORDANCE WITHASTMM12
EDGE DISTANCE10 WOOD 'NOOD SIGNED:06/24/2015
�11111(f.!
SCREW FRAMING Eastern �o ,a \\��� g L p��/�
1 1/4" MIN. BY OTHERS �sremN[rKsevLr \�\\s
APPROVED E1dBEDMf ^r -._a. waive° ftooama �r•�\G.ENa
SEALANT ,`'. °°°�'° F'- _
BEHIND FIN VERTICAL CROSS SECTION SERIES 176 SH VINYL SINGLE HUNG WINDOW �*' o��L'S
WOOD FRAMING OR 2X SUCK INSTALLATION IMPACT 54" X 77" (7C�
INSTALLATION DETAILS ; STATE OF
DRAWN: OPIK,':A. FEV jFd;..c�OR10P
16. iG1E oau o8—S02538 A SYONAj1E�\\\�
NTS 11/17/14 -!:E7 OF 7
i
Florida Building Code Online Page 1 of 6
o o- '
va
r
Flolida Department! BCIS Home Log In I User Registration Hot Topics Submit Surcharge Stats&Facts Publications FK Staff I SCIS Site Map I Links I Search
Busines.
PruAp
Professi nal 4USEoR:d
Pubicc UrserOVdI
Regulation
Product ADDroval Menu>Product or Application Search>Application List>Application Detail
FL# FL12334-R6
Application Type Revision
Code Version 2014
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived ❑
Product Manufacturer Therma-Tru Corporation
Address/Phone/Email 118 Industrial Drive
Edgerton,01-143517
(419)298-1740
rickw@rwbldgconsultants.com
Authorized Signature Vivian Wright
rickw@rwbidgconsultants.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
Compliance Method Certification Mark or Listing
Certification Agency National Accreditation&Management Institute
Validated By Ryan J. King,P.E.
W Validation Checklist-Hardcopy Received
Referenced Standard and Year(of Standard) Standard Year
ASTM D1929 1996
ASTM D2843 1999
ASTM D635 2003
ASTM D638 1996
ASTM E1300 2004
ASTM E84 2000
ASTM G26 1995
TAS 201,202,203 1994
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
FL12334 R6 Eguiv of Standards.odf
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtF2AeAma 9K... -
• f ,
v.ivlrua Uuliuutg 4.vuu viume, rage l of 0
Product Approval Method Method 1 Option A
Date Submitted 03/10/2016
Date-Vaildated 03('14(2016
Date Pending FBC Approval
Date Approved 03/13/2016
Date Revised 10/13/2016
SuMMary of Products
FL# Madel,Number or Name Description
12334.1 a."ClassicCraft","CiassicCraft 'Impact"8'0'Glazed Fiberglass Single Door utilizing Hoppe
Rustic",'FiberClassie or Multi Point lock-Outswing configuration(X)
'SmoothStar"Series
Urnits of use Certification Agency ertil ieate
Approved for use in HVHZ:Yes FL12334 R6 C CAC 12334.1 NAMI CERT.odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 03/31/2026
Design Pressure:N/A Installation Instructions
other-.,See INST 12334.1-for Design Pressure Ratings,any FL12334 R6 II INST 12334.1.adf
additional use limitations,installation instructions and Verified By:Lyndon F.Schmidt,P.E.43409
product particulars.(Note-ASTM E1300-04 utilized for Created by Independent Third Party:Yes
areas inside the HVHZ) Evaluation Reports
FL12334 R6 AE EVAL 12334.1,
FL12334 R6 AE TT-PLASTICS,1.odf
Created by Independent Third Party:Yes
12334.2 b.'ClassicCraff,"ClassicCraft "Impact"8'0 Glazed Fiberglass Single Door with Sidellte
Rustic',"FiberCiassic"or utilizing Hoppe Multi Point lock-.Outswing configuration(OX
"SmoothStar'Series or XO)
Units of Use Certification Agency Certificate
Approved for use in HVHZ;Yes FL12334 R6 C CAC 12334.2 NAMI CERT.odf
Approved for me outside tlVJM Yes . Quality Assurance Soldract ExpirWOR Date
Impact Resistant:Yes 03/3112026
Design Pressure:N/A Installation Instructions
Other.See INST 12334.2 for Design Pressure Ratings,any FL12334 R6 II INST 12334.2.odf
additional use limitations,Installation instructions and Verified By: Lyndon F.Schmidt P.E.43409
product particulars.(Note-ASPM E130044 utilized for Created by Independent Third Party:Yes
areas inside the HVHZ) Evaluation Reports
FL12334 R6 AE EVAL 12334 2.odf
FL12334 R6 AE TT-PLASTICS,1.Qdf
Created by Independent Third Party.Yes
12334.3 c.'ClassicCraft",'ClassicCraft "Impact"8'0 Glazed Fiberglass Single Door with Sidelites
Rustic","FiberClassle or utilizing Hoppe Multi Point lock-Outswing configuration
'SmoothStar'Series '(OXO)
13mits of use Certification Agency Cer#W=a to
Approved for use in HVHZ:Yes FL12334 R6 C CAC 12334.3 NAMI CERT.odf
Approved for use outside HVHZ:Yes Quality Assurance Cmatract Expiration Data
Impact Resistant:Yes 03/31/2026
Design Pressure:N/A Installation Instructions
Other.See INST 12334.3 for Design Pressure Ratings,any FL12334 R6 II INST 12334.3.odf
additional use limitations,installation instructions and Verified By:Lyndon F.Schmidt,P.E.43409
product particulars.(Note-ASTM E1300-04 utilized for Created by Independent Third-Party:Yes
areas inside the HVHZ) Evaluation Reports
FL12334 R6 AE EVAL 12334.3.odf
FL12334 Rfj AE TT-PLASTICS 1 od€
Created by Independent Third Party:Yes
1.2334.4 jd.'ClassloCraft°,"ClassicCraft "Impact"8'0'Glazed Fberglass'Dauble Door utilizing Hoppe
Rustic',"FiberClassie or Multi Point loch-Outswing configuration(XX)
"SmoothStar"Series
urnits of use Certification Agency Certificate
Approved for use in HVHZ:Yes FL12334 R6 C CAC 12334A NAMI CERT odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration-Date
Impact Resistant:Yes 03/31/2026
Design Pressure;N/A Installation Instructions
Other:See INST 12334.4 for Design Pressure Ratings,any FL12334 R6 II INST 12334 4 odf
additional use limitations,installation Instructions and Verified By:Lyndon F.Schmidt,P.E.43409
product particulars.(Note-ASTM E1300-04 utilized for Created by Independent Third Party:Yes
areas inside the HVHZ) Evaluation Reports
FL12334 R6 AE E_VAL 12334.4.1)d
FL12334 R6 AE TT-PLASTICS 1 odf
Created by Independent Third Party:Yes
drip.//www.floridabuilding.org/pr/pr app_ tl.aspx`PaMM=WGEVXQwtDgtF2Aezuarjg3K.,,, 7/26/2017
rv>.Lua iju11u111g t-oue unime Page 3 of 6
12334.5 e.'ClassicCraft","ClassicCraft "Impact'8'0 Glazed Fiberglass Double moor with S•sdelites
Rustic","FiberClassie or utilizing Hoppe Multi Point lock-Outswing configuration
"SmoothStar"Series (OXXO)
Limits of Use Certification Agency Cestiftate
Approved for use in HVHZ:Yes FL12334 R6 C CAC 12334.5 NAMI CERT_pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Reststimu Yes 03/31/2026
Design Pressure:N/A Instunation instructions
Other:See INST 12334.5 for Design Pressure Ratings,any FL12334 R6 II INST 12334 5 odf
additional use limitations,installation instructions and Verified By:Lyndon F.Schmidt,P.E.43409
product particulars.(Note-ASTM E1300-04 utilized for, Created by Independent Third Party:Yes
areas inside the HVHZ) Evaluation Reports
FL12334 R6 AE EVAL 12334 5 pdF
FL12334 R6 AE TT-PLASTICS 1 pdf
Created by Independent Third Party:Yes
12334.6 f."Classiccraft","Classiccraft "Impact"8'0"Glazed Fiberglass Single Door-Outswing
Rustic",'FiberClasste or contiguralion(X)
"SmoothStar'Series
Limits of Use Certification Agency-Certificate
Approved for use in HVHZ:Yes FL12334 R6 C CAC 12334,6 NAMI CERT odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 03/31/2026
Design Pressure:N/A Installation Instructions
Other:See INST 12334:6 for Design Pressure Ratings,any FL12334 R6 II INST 12334 6 odf
additional use limitations,installation instructions and Verified By:Lyndon F.Schmidt,P.E.43409
pro¢uot parMPlars.(Note-ASTM El 300-04 utilized for Created by Independent Third Party:Yes
areas inside the HVHZ) Evaluation Reports
FL12334 R6 AE EVAL 12334 6 pdf
FL12334 R6 AF�TT-PLASTICS i pdf
Created by Independent Third Party:Yes
12334.7 g."ClassicCraft","ClassicCraft "Impact'8'0 Glazed Fiberglass Single Door with Sidelite-
Rustic","FlberCJasslc".or Outswing configuration(OX or XO)
'SmoothStar'Series
Limits of Use Certification Agency Cettilkate
Approved for use in HVHZ:Yes, FI-12334 R6 C CAC 12334.7 NAMI CERT pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 03/31/2026
Design Pressure:NIA installation Instructions
Other:See INST 12334.7 for Design Pressure Ratings,any FL12334 R6 II INST 12334 7 odf
additional use limitations,installation instructions and Verified By:Lyndon F.Schmidt,P.E.43409
product particulars.,(Note-ASTM E1300-04 utilized for Created.by Independent Third Party:Yes
areas inside the HVHZ) Evaluation Reports
LI 334 R6 AE EVAL 12334.7.i)df
FL12334 R6 AE TT-PLASTICS 1 pdf
Created by Independent Third Party:Yes
12334.8 h."ClassicCraft","ClassicCraft 'Impact"$'0 Glazed Fiberglass Single Door with Sidelites-
Rustie,'FiberClassic"or Outswing configuration(OXO)
'SmoothStar"Series
Limits of Use Cartiflication Agency Certifscate
Approved for use In HVHZ:Yes FL12334 R6 C CA_C 12334.8 NAMI CERT pdf
Approved-for useoutside HVHZ:Yes Quality Assurance.Contract_Expiration Isatin
Impact Resistant:Yes 03/31/2026
Design Pressure:N/A Installation Instructions
Other:See INST 12334.8 for Design Pressure Ratings,any FL12334 R6 II INST 12334 8 pdf
additional use limitations,installation instructions and Verified By:Lyndon F.Schmidt,P.E.43409
product particulars.(Note-ASTM E1300-04 utilized for Created by Independent Third Party Yes
ureas inside the HVHZ) Evaluation Reports
FL12334 R6 AE EVAN.12334$pdf
FL12334 R6 AE TT-PLASTICS Lod
Created by Independent Third Party:Yes
12334.9i."ClassicCraft","ClassicCraft 'Impact"8'0"Glazed Fiberglass Double Door-Outswing
Rustic","FiberCiassic'or configuration(XX)
'SmoothStar"Series
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL12334 R6 C CAC 12334.9 NAMI CERT.pd
Approved for-use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 03/31/2026
Design Pressure:N/A Inptal[W-9n Instructitrns
Other.See INST 12334.9 for Design Pressrum Ratings,any FL12334 R6 II INST 12334 9 odf
additional use limitations,installation instructions and Verified By:Lyndon F.Schmidt,P.E.43409
product particulars.(Note-ASTM E1300-04 utilized for Created by IndependentThird Party:'Yes
areas inside the HVHZ) Evaluation Reports
FL12334 R6 AE EVAL 12334 odf
FL12334 R6 AE TT-PLASTICS 1 odf
Created by Independent Third Party:Yes
hnp,//www floridabuilding.org/pr/pr_app sitl,aSPX?Pagano=WGEVXQwtDgtF2Aezua�g&,, 7/26/2017
Page 4 of 6
12334.10 j.'ClassicCrafr,"ClassicCraft -Impact-WO Glazed Fiberglass Double Door with Sidelites-
RusUe,'FiberClassie or Outswing configuration(OXXO)
"SmoothStar"Series
Limits of Use Certification Agency Certificate
Approved for use in HVHZ.Yes FL12334 R6 C CAC JXZL34.10 NAMI CERT,od
Approved for use outside HVHZ:,yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 03/31/2026
Design Pressure:.N/A Installation Instructions
Other:See INST 12334.10 for Design Pressure Ratings, FL12334 R6 11 INST 12334.10.pd
any additional use limitations,installation insto-uctions and Verified By,Lyndon F.Schmidt,P.E.43409
product particulars.(Note-ASTM E1300-04 utilized for Created by,Independent Third Party:Yes
areas inside the HVHZ) Evaluation Reports
FL12334 R6 AE EVAL 12334.10.0
FL12334 R6 AE E_-PLASTICS.I.Dolf
CM-ated by independent Third P,3rtr.Yes
12334.11 k.-ClassicCrafV,-ClassicCraft 'Impact'810"Glazed Fiberglass Single Door utilizing Hoppe
Rustie,'FiberCiassie or Multi Point lock-Inswing configuration(X)
Limits of Use 'SmoothStarl Series Certification Agency Certificate
Approved for use in HVHZ-.Yes FL12334 R6 C CAC 12334.11 NAMI CERT.I)d
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant-Yes 03/31/2026
Design Pressure:N/A Installation Instructions
Other.See INST 17334.11 for Design Pressure Ratings, FL 2334 R§ Il INST 12334.11,nd
any.addilignof use limitations,in0talloflon instru do
- -cliorts and Vgrifted By. Lyndon F.$chmiflt,P.E.43409
product particulars.(Note-ASTM E1300-04 utilized for Created by Independent Third Party.Yes
areas inside the HVHZ) Evaluation Reports
FL12334 RG AE EVAL 12334.11.pdf
FL12334 R6 AE TT-PLASTICS 1.pdf
Created by Independent Third Party:Yes
12334-12 1.1.-ClassicCraft-,'ClasslaCtaft "Impact"8'0 Glazed Fiberglass Single.Door with Sidelite
Rustic",'FiberClassic"or utilizing Hoppe Multi Point lock-Inswing configuration(OX
'SmoothStar'Series or XO)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL12334 R6 C CAC 12334.12 NAMI CERT,I)d
Approved for use outside HVHZ-.Yes Quality Assurance Contract Expiration Date
Impact Resistant-Yes 03/31/2026
Design Pressure:N/A Installation instructions
Other See INST 12334.12 for Design Pressure Ratings, FI12334R6 11 INST 12334.12.pdf
any additional use limitations,installation Instructions and Verified By:Lyndon F.Schmidt,,P.E.43409
product particulars.(Note-ASTM E1300-04 utilized for Created by Independent Third Party:Yes
areas inside the HVHZ) Evaluation Reports
FL12334 R6 AE EVAL 12334.12.pdf
FL12334 R6 AE TT-PLASTICS 1.p df
Created by Independent Third Party.Yes
12334.13 in."ClassicCrafV,"ClassicCraft "Impact"WO Glazed Fiberglass Single Door with Sideiltes
Rustic',"FiberClassic"or utilizing Hoppe Multi Point lock-Inswing configuration
"SmoothSta r"Series (6x0)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL12334 R6 CAC 12334,13 NAMI CERT.pd
Approved for use outside I"Z-Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 03/31/2026
Design Pressure:N/A Installation Instructions
Other.See INST 12334.13 for Design Pressure Ratings, FL12334 R6 11 INST 12334.13.pdf
any additional use limitations,installation instructions and Verified By:Lyndon F.Schmidt,P.E.43409
product particulars.(Note-ASTM E1300-04 utilized for Created by Independent Third Party:Yes
areas inside the HVHZ) Evaluation Reports
FL12334 R6 AE EVAL 12334,13.f)df
FL12334 R6 AE TT-PLASTICS.1.0f
Created by Independent Third Party.Yes
12334.14 n."ClassicCraft,'ClassicCraft 'Impact"&0"Glazed Fiberglass Double Door utilizing-Hoppe
Rustic',"FiberClassic'or Multi Point lock-Inswing configuration(XX)
"SmooffiStar"Series
Limits of Use Certification Agency Certificate
Approved for use in HVHZ-Yes FL12334 R6 C CAC 12334.14 NAMI CERT.pd
-Approved for use outside t#VHV—^Yes Quality Assurance Contract Expiration Date
Impact Resistant.Yes 013112()26
Design Pressure-N/A installation instructions
Other:See INST 12334.14 for Design Pressure Ratings, FL12334 R6 11 INST 12334.14.gdf
any additional use limitations,installation Instructions and Verified By:'Lyndon F.Schmidt,P.E.43409
product particulars.(Note-ASTM E1300-04 utilized for Created by Independent Third Party;Yes
areas Inside the RVHZ) Evaluation Reports
FL12334 R6 AE EVAL 12334.14.0f
http://www,floridabuilding.org/pr/pr_app_dtl,aspx?par,am-7wGEVXQwtDqtF2AozuadgK.. 7126/2017
i av�iurt yttilUlu�%,uuc urnine Page 5 of 6
FL12334 R6 AE TT-PLASTICS.i.pdf
Created by Independent Third Party:Yes
12334.15 o.'ClassicCraft','ClassicCraft "Impact'8'0 Glazed Fiberglass Double Door with Sideiites
Rustic",'Fiberaassic"or utilizing Hoppe Multi Point lock-InsMog configuration
"Smooth5tail Series (OXXO)
limits of Use Certification Agency Certif a to
Approved for use In HVHZ:Yes FL12334 R6.C. CAC 12334 SS NAMI CERT pd€
Approved for use outside HVHZ:Yes Quality Assurance contract Expiration Date
Impact Resastarb Yes
3/3112026
Design Pressure:N/A Instaliafion Instructions
Other.See INST 12334.15 for Design Pressure Ratings, FL12334 R6 II INST 12334.15_gdf
any additional use limitations,installation Instructions and Verified By:Lyndon F.Schmidt,P.E.43409
product particulars.({Yate-ASTM E1300-04 utilized for Created by Independent Third Party:Yes
areas Inside the HVHZ) Evaluation Reports
FL12334 R6 AE EVAL 12334.15.odf
FL12334 R6 AE TT-PLASTICS.1.gdf
Created by independent Third Party:Yes
12334.16 p.'CiassicCraft","ClassicCraft 'Impact"8'0'Glazed Fiberglass Single Door-Inswing
Rustic",'FiberClassic'or configuration(X)
"SmoothStar"Series
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL12334 R6 C CAC 12334.16 NAMI CERT,pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 03/31/2026
Design pressure:N/A tnstallation Instructions
Other.See INST 12334.16 for Design Pressure Ratings, FL12334 R6 II INST 12334 16 pdf
any additional use limitations,installation instructions and Verified By: Lyndon F.Schmidt,P.E.43409
product particulars.(Nate-ASTM E1300-04 utilized for Created by Independent Third Party:Yes
areas inside the HVHZ) Evaluation Reports
FL12334 R6 AE EVAL12334.16.pdf
FL12334 R6 AE TT-PLASTICS.1 pdf
.Created by IndependentThlyd.Party:Yes
12334.17 Q.'classiccraft","Classil:craft "impact"8'0 Glazed Fiberglass Si.ngie Door with.Sidelite-
Rustic,'FiberClassic'or Inswing configuration(OX or XO)
"SmoothStar'Series
Limits of Use Certification Agency.Certificate
Approved1br use in HVHZ:Yes FL12334 R6 C CAC 12334 17 NAMI CERT.pd
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact ReSistarri;Yes 03/31/2026
Design Pressure;N/A -Installation Instructions
Other:See INST 12334.17 for Design Pressure Ratings, FL12334 R6 I1 INST 12334 17 odf
any additional use limitations,installation instructions and Verified By.Lyndon i.Schmidt,.P-E.43409
product particulars.(Note-ASTM E1300-04 utilized for Created by Independent Third Party:Yes
areas inside the HVHZ) Evaluation Reports
FL12334 R6 AE EVAL 12334.17.t�df
FL12334 R6 AE TT-PLASTICS.1.g_df
Created by Independent Third Party:Yes
12334.1Er."-ClassicCraft",'CtassicCraft 'Impact"8'0 Glazed•Fiberglass Single Door with Sidelites-
Rustie,"FiberCiassic'or Inswing configuration(OXO)
"SmoothStar'Series
Limits of Use Certification Agency certilikate
Approved fnruse 1.MVHZ:Yes FL12334 R6 C CAC 12334 18 NAMI CERT.pdf
td Approved for use outside HVHZ:Yes Quality Assurance Contract Exp-nation Date
Impact Resistant:Yes 03/31/2026
i Design Pres sure:N/A Installation Instructions
Other.See INST 12334.18 for Design Pressure Ratings; FL12334 R6 i1 INST 12334.18,pdf
0 any additional use limitations,installation instructions and Verified By:Lyndon F.Schmidt,P.E.43409
product particulars.(Note-'ASTM E1300-04 utilized for Created by Independent Third Party:Yes
areas inside the HVHZ) Evaluation Reports
FL12334 R6 AE E/tAL 12334 18 pdf
FL12334 R6 AE TT-PLASTICS.I.pdf
Created by Independent Third Party:-Yes
12334.19 s.'"ClasslcCraft%"ClassicCsaft "Impact"8'0"Glazed Fiberglass Double Door-Inswing
Rustic,"FiberCiassic or configuration((X)
'5mmthStar"series
Limits of Use Certi kation Agency Certi cote
Approved for use in HVNZ;.Yes FL12334 R6 C CAC 12334.19 NAMI CERT.pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 03/31/2026
Design Pressure:N/A Installation Instructions
Other.See INST 12334.19 for Design Pressure Ratings, FLi2334 R6 II INST 12334 19 pdf
any additional use limitations,installation instructions and Verified By:Lyndon F.Schmidt,P.E.43409
Created by Independent Third Party:Yes
http://www floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtF2Aezu,-ujglC.. 7/26/201.7
uunaing Code Online
Page 6 of 6
P;: particulars.(Note-ASTM E1300-04 u7:]C—ated
forEraheatiara Reports
areas inside the HVHZ)
FL12334 R6 AE EVAL 12a34 i9 pdf
FL123344 R6 AE_7T-PLASTICS i odr
by Independent Third Party:Yes
17334.20 t."ClassicCraft","ClasstcCraft "Impact"S'0 Glazed Fiberglass Double Door with Sidefites-
Rustle, FiberClassic".or Inswing configuration(OXXO)
"SmoothStar"Series
Limits of Use Certification A
Certiff
Approved for use in HVHZ:Yes R '
FL12334 R6 C CAC 12334,20 NAMI CERT odf
A pact R for irse aulside HVHY Yes Quality Assurance Contct.E
raxpiration Date
Impact Resistant:Yes 03/31/2026
Design pressure:N/A Installation Instructions
Other:See INST 12334.20 for Design Pressure Ratings, EL12334 R6 II INST 12334 20 Ddf
any additional use limitations,installation instructions and Verified By:Lyndon F.Schmidt,P.E.43409
-product particulars.(Note-ASTM€1300-04 utilized for Created by Independent Third Party:Yes
areas inside the HVHZ) Evaluation Reports
FL12334 R6 AE EVAL 12334.20.1)df
FL12334 R6 AE TT-PLASTICS 1 Ddf
Created by Independent Third Party:Yes
back I Next
Canta4#yg::2601 Blair Stone Road Tallahassee FL 32399 Phone:850-4§7-1824
The State of Florida is an WEED employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility tatement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please dick bar .
Product Appmval AcMts:
a5Q, WN Ka 0
Credit Card
Safe
'Q�'DW-' lAe,z�a j��,,, "I12612Q17
.. 1i
THERMAITRU
THERMA TRU DOORS
1 1 B INDUSTRIAL DR., EDGERTON. OH 4351 7 °
SMOOTH STAR FIBER CLASSIC - 116.75 ru,X.OAFTL4ME �.,,,;11 ;t%,•��° o �z
W/2X MULL.REINF.
' ' a xz
CLASSIC CRAFT & CLASSIC CRAFT RUSTIC 37°50 MAX37.75*MAX E E� m
FRAME WIDTH�j FRAME WIDTH—� Q� Y 9 d t a
! - a 01 0 (L
r
FIBERGLASS GLAZED DOOR WITH SIDELITES PANEL WZ
INSWING _ N:
`IMPACT` Ca
w
O W2
GENERAL NOTES
/ itg o_x
�U
T. This product anchoring drawing has been developed in compliance with the 5th Edition(2014)Florida
Building Code(FBC)including the"High Velocity Hurricane Zone(HVHZ).See the Certification Agency rs a y ori
Certificate forsrzes,specifications and ratings. t7 = xs H
_ L
2. Product anchors shall be as fisted and spaced as shown on details.Anchor embedment to base materiel
shall be beyond wall dressing or stucco. <
° 3. When used in fhe HVHr this product complies with Section 1626 of the FBC and does not require an S °
impact resalonlcovering. C O x O 4 m
4. When used In areas outside of the"HVHr requiring wind borne debris protection this product cornpries withe
Section 1609.12 of the FBC and does not r
equve an impact resistant covering.This product meets missile
level"V and includes Wind Zone 4 as defined in ASTM E 1996 and Section 1609.1.2.2 of the FBC.
0
j ` x
•� 5. For 2z stud framing corstnrction,anchoring of these units shall be the some as that shown for 2x buck � %�' �;%' /:• d�� z
o` masonry construction.
N_
6. Site conditions that deviate from the details of this drowing require further engineering analysis by a
Gcersed engineer or registered architect. o o
2 U
0 7. Inswing configurations using sill item 1133 do not meet the water infiltration requirements for the'HVHT and 1.5 REINFORCEMENT ¢•w�y
a shag be installed only in non-habitoble areas or of habitable locations protected by an overhang or 0-
canopy such that the angle between the edge of canopy or overhang to sill is less than 45 degrees.
TABLE OF CONTENTS o m a a a
z SHEET DESCRIPTION SHEET DESCRIPITON
z
1 Typical elevations,design pressures&general notes 8 Vertical cross sections I n a z o°
Z 2 Door panel details$glazing details(Smooth Stor) 9 Vertical cross sections ah, 3�r 7 09 a
3 Door panel details(Fiber Classic] 10 Buck anchoring OWEIZALLw DESfGN PQESSUREPSQ; o
4 Door panel details Classic Croft N.I.S.
P l 1 11 Frame anchoring 2X buck masonry construction Sfq//NC FRAME
5 Doer panel details(Classic Croft Rustics 12 Frame anchoring IX buck masonry construction : _ 1)I ttENSf01( PC}S1TNE NEGi47TV�i;: o 8 0 JK m
6 Siderite panel details 13 Big of maferiols 000 BY. LF 3
7 Horizontal cross sections
INSWING 115.75"x97.17" +50.0 -55.0 °A�NNG"O.0
5 FL–f 2334.113 v
0
u s+r:Er OF 13
R'\Clients\Therms Tru PERMANENTVWdda Product Approvals\FL-12334\Drawings\Cutrent\FL•12334.16.20.d",C-2
a
Q
Q
0
0 g a
a O .
0
Om D
O �
�-1.54"
rn
Q m w
m
p ro
� i
O 0
2 N
---
O
f N
N
D D
�4 zm a
1) A yam.
p
N
b
N N Ui
AI T O OD
r _
PC
N
m
No.43409•'
PRODUCT: Dooumanb Prepared Byn'.- UVU OF
THERA{A TRU Lyndon P. Sohm(dt i�
3 2 OS 15 UPDATE TO $TtJ ED. 2014 F8C US RGERGLASS GLAZED DOOR P.E. No. 43409 *"'M/�lAt.\\
W r^ -i 4 2 3 6 12 REVISE TO CERT. MARK METHOD LFS PART OR ASSEMBLY: CD��f/ BUIIhINO CONSULTMIiS,�NC.
r l !' '*r �' ir1�" 7 3/9/11 REWSE CLASSIC CRAFT DOOR JK YY A.O. Box 230, Vatrioo, FL 33595
u to NO DATE BY DOOR PANEL DETAILS & GLAZING phone No.: 813,659.9197
REVISIONS DETAILS (SMOOTH STAR) FBPE CA No. 9813
02009 R.W.BUILDING CONaOLTANTa INC.
IL aenls\Thenm Tim PERWMENTVtorida Product Appmvatt\FL,12334\DtaMngs\Cuttent\FL-1233416-20.dwg,C-3
79.43"MAX,D.L.O.
0
0
0 ua
0)
G\,1
0,911,
'a
M
M
0 0
lot:
all
I AS'
(A
C- I�
M
;0 Vt
ESQ
's
0
M
No,43409
.)rz
PRODUCT: Doan -t.pmcomd
THERMA-TRU Lyndon F. Schmidt • ..........
FIBERGLASS GLAZED DOOR P.E. No. 43400
jw —3 M21.5 UPDATE TO
5'H'ED, (2014 FDC -L-Ffl - a "I'm Ii%%%%
WSF TO CERT. MARK METHOD CONSULTANTS' 0.
2 JFS PART OR ASSEMBLY:
REVISE CLASSIC CRAFT JK spu.nIN.C.- -'30 Voldco, FL 33505-
MOR BY
DO?f PANCELLASOSET
NO__gATE I IBER ICILS Ph.,. No.: 81.3,659.9197
b _1 REVISIONS I FSPE C.A. No. 98t3
0 2009 R.W.BUILDING CONDULTAWS INC.
R�Qients\Therrm Tru PERMANENT\Flodda Ptoduct Approvals\FL-12334\Drawings\Current\FL-12334.16-20.dwg,C-4
....... 79.0 D.L.O. P
9-2
o >
0
0
M;. 0
0
3- W
0
0
0
0
0
OO
1 0
0
L000- =
0
0
01,
0 cc
0
/ZN
0.91"
Mr
01.
C;
1.49"
0.81"
I70
A
I I
PO
m
-0
W
140.43409
I PRODUCT.. tWcumenb PftpuMd or.
midt
THERMA-TRU V�ndon F. Soho
I FIBERGLASS GLAZED DOOR No. 434C
—3 UPDATE TO 5THED. LFS I "
(2O 14) FDC BUILDING C.
2 REVISE TO CERT. MARK METHOD LFS PART OR ASSEMBLY-
OTR NELCRDAEMTAILS P.O. Do. 230, Wrico, FL 33595
I M-3 REVISE CLASSIC CRAFT DOOR JK I
CLAA
-go— DATE BY
SIG Ph-A6 No.; 813.659.0197
REVISIONS FaPE C.A. No. 9813
02009 R.W.a......a Ca.8—T.—.1"..
RACllents\Therma Tru PERMANENT\Flodda ProductApprovalsVL•14334\Drawings\Current\PL-12334.16.20Ahs C•5
79.63"MAX.D.L.O,
0
A
I 1
0 0 c"
s' o
(> w
3 a' O o ED
G, O
0
�O
O
N -
Am o
�m� s
Z H
A
(JI 700 t11
s i
} �s L.n �u sk}'r r�nt3,yt's•Y�,44 L}i iL:r''tt y't cl in�,sS —' A
v rt£y` r. Asst�� �eYs�Y�.,-'•��il iv h � /csy -s +� n`j
}s:':ra1:'.i t:•,.�•.i'ys tt*:. s` '..Y.Ii::�h j�' ^S•"r.L,^. _L � A
7.9a"—• M
w
f I.4Y
H W
i'�z 5"iti
n
n
< ; P
O
1�,..
m
A .'O N ` ••
No.43408
*_ * 3I
Zs/3-
" 0 Q PRODUCT: Daoumanta Pnp—d OF. •.
THERMA-TRU Lyndon F. Schmldt i '• �o1ac�1•''
IN w z 3 2 06 15 UPDATE TO 5TH ED. 2074 F8C LF3 FIBERGLASS GLAZED DOOR P.E. No. 43409 /// s+��......
R W y v 2 3 6 12 REVISE TO CERT. MARK METHOD LFS PART OR ASSEMBLY: GD�/�� BUILDING CONSULTANTS, .
Iw po z m NO DATE REVISE CLASSIC CRAFT DOOR eK DOOR PANEL DETAILS tJ�tY phone No23813.6 9.0. 91 7 J3895
REVISIONSI (CLASSIC CRAFT RUSTIC) FBPE CA No. 9813
0 2009 H.W.DUILOINo CONOULTANTe IND,
RNCllenU\Thermo Tru PERMANENT\Florida Product Approvats\FL•12334\Drawings\Current\FL•12334.16.20.dwg,C-6
79.63"MAX,D.L.O. ro
r. .
Q O�
o _
r—
m D •��
A r
O
m 0
O 0
� a 0 0
Z6
a 0
0
A O p•�.
� 0 A z
N
b " A
0,66•' D
70 OIA
O A c.1
N
' O
Z
••Tr' •WO
0.66'
00
O•N OD
N W A
M
T1 A
AI
y
m
Z a
Cu w
N o• N � A \`\tLlLllllll!/�f/
A ITr
No.43409
b PRODUCT: Doeum.nh Pnp—d
THERMA TRU Lyndon F. Sehmldtf2gp0/,.•'
FIBERGLASS GLAZED DOOR P.E. No. 43409 �i,t43j'••• `��`�
°I N o 2 3 2 06 15 UPDATE TO 5TH ED. 2014 FBC LFS !l///j�1/4�11\\1
3 6 12 REVISE 70 CERT. MARK METHOD LFS PART OR ASSEMBLY: G���! BUILDING CO NSULTANTS�I��C.
IL' pe N 1p NO DATE11 REVISE CLASSIC CRAFT DOOR BY SIDELITE PANEL DETAILS YY P.O. Boy 230, Volrico, FL 33595
Phone No.: 813.839.9197
REVISIONS FBPE C.A. No. 9813
2009 R.W.Bt11L01NO CONBULTANTB INO.
k\Clients\Therms Tru PERMANENT\Florida Product Approvals\FL•12334\Drawings\CunentVL-12334.16.2o.dwg,C-7
•°a C Ft
° t
° 41
0 0 �g
0
03 z
Vf :`
m z3 _� tnN
O
Z
A O •o w •"
0
O rn b N
n y> �
Z> �Z
V N j
L V A
O
� nt a— lH !7S
N
181
A _ ami
G a�
Ila
z; o
n z w �+
0 0
o 0
O p
V O•
O O
Hy
n Zloe
V W O V .p O O O Eri
Z• f 0 n \ �
X
H - c A m
d _
7n0 `� y •.. ra < .v 1
.V
z
Ooo O
2 m
\1011111114
No.43409
S PRODUCT: Dxvmant.Pr"—d_Vrn QOITE or f•
iHERMA TRU Lyndon F. Schmidt ��i� +�g50f�•,.•'
L4 FIBERGLASS GLAZED DOOR P.E. No. 43409 •�"
I`r W Z 3 2 06 15 UPDATE TO 5TH ED. 2014 FBC LFS
$ a < 2 3 6 12 REVISE i0 CERT. MARK METHOD LFS PART OR ASSEMBLY: LD��/ BUILDING CONSULTANT
y 1; p 1 3 9 f i REVISE CLASSIC CRAFT DOOR JK YY P.O. Box 230. Vafrlco. FL 33595. _
IC, m NO DATE By HORIZONTAL Phone No.: 813.659.9197
REVISIONS CROSS SECTIONSFBPE C.A. No. 9813
0 2009 R.W.BUIr.Dlna GoneULTANTS No.
0.NCllents%Therma Tru PERMANENTV106da Product Approvals\FL•12334\Drawings\Curmnt\FL•12334.1830.dwg.C•8
v ^'
O
� o 0
a
b
r - •'o.
O
Cc v
m �
m
Z 0
C`SINK- a
(TYP.)
T'1J4"MLN.
EMB.(ttP.) t 8 EMB.(TYP.j
o o M
v v .Oro
n �
m
goer i:: g; M
xO o o �-
° ro A
o C �
to
m n
Z .Oro -
m V n
°
0
1.1/4"MIN.
EMB.(TYP.)
�tttlllli!!tt
No.43409
Y .._. PRODUCT: Do-to Pmpor.d Or. 6TAYC OF •• ,�
r'1 ` THERMA TRU Lyndon F. Schmidt 'i, `'•F2tJfG6R�' �Q
I t FIBERGLASS GLAZED DOOR P.E. No. 43406
Ioc A S Z 3 2 06 15 UPDATE TO 5TH ED, 2014 FBC LFS IL11IIi1tt
2 3 6 12 REVISE TO CERT. MARK METHOD VS PARI OR ASSEMBLY: GDnl/ BUILDING CONSULTANTS, INC.
tix to p 1 3 6 1 t REVISE CLASSIC CRAFT DOOR JK VERTICAL YY P.o. Boz 230, Vatrlco, FL 33595
po `O NO DATE BY CROSS SECTIONS Phone No.: 613.656.0107
REVISIONS FBPE C.A. No. 9813
0 2009 R.W.BUILOINO CONSULTANTS INC.
G
FLACIlents\Therma Tru PERMANENT\Fiorida Product Approvals\FL-12334\Drawings\Cunent\FL-12334.16.20.dwg.C-9
� m
A22 pppp to
O
2
< Go 4
tTt •
Lmf1 � •a
N
to •.
T �•
Z p•
4
M
A
1.I/4"MIN. C'SINK
EMB.(TYP.( (TYP.(
N
0 m A
< v r M
' t
EMB.
EMB.(TYP.)
O n �' 5`r•
on
N :A.�..
'•d' r�+i� A _
76
Go
"�T
V
t 4 I A r^ O D
P t
m x r—
�A
2
!!Z � V
Iz p
6A
� 3 m
ogx .v
b
c 3 T
a au
ro 1-1/4"MIN.
$ EMB.(TYP.)_.-._
9 6 \\%% �18CHMff��i'
v`-* I..
j' No.43409 '
PRODUCT: Documents PfapOrod 13y:--:, • OL1181
F76ERGLASS GLAZED DOOR Lyndon F. Schmidt i AtO..... `
P.E. No. 43409 �� �•••••••••
to N Z 3 2 06 15 UPDATE-TO 5TH ED. 2014 FBC IFS
0 W`' ff1111 1111
a ` 2 3 6 12 REVISE i0 CERT: MARK METHOD LFS PART OR ASSEM13LY: LDqBUILDING CONSULTANTS,�NC.
It W N x to NO OATEf 1 REVISE CLASSIC CRAFT DOOR eY VERTICAL VU P.O. Box 230, Volrleo, FL 33595 ,
CROSS SECTIONS Phone No.: 813.859.9197
REVISIONS FBPE C.A. No. 9813
0 2009 R.W.BUILDINO CONSULTANTS INC.
_a_Tru m___aProduct Appr_+12334\Drawi __-123 - C-10
'n §§ § \&j§
m : , 5.__ , _
Kk ; \7R; \Sq
ook : . , , , Ee £m
o ,
Z d §{(: a § %
� �: x ,-• _
. k
P.61 z
d : «am0}(§
d� ; &|/an
Q:)3 -
I kE�
§/
90 I o
/ §\OR2 \[
bl, ® m & y
.
..§.
(E2 &
° U
A/\ \\\ \ -
$&®
$ 7
&7 2R (
®
%$I o
d$R \® \
�
/ ER
�/ƒ
) m(�
k
- — - _ _ _ _ _ -
. �
Oil
.�
.�.) <
No,43409
\�
; . I_wr __.___§ +'r� r +_ e __t �
\ G § & , z a a u = s m mi _
FIBERGLASS c z o a « _
MARx� sLFS
LART OR ASSEMBLY.
.zteems CRkFT DOOR JK � �� �
_ek��m/\ \ BUILDING WONSU
� o/ W � �
« 0S _ec + _,
o_9 B___�__. a
'
Q
M SEE NOTE 2 0
(TYP.) ^O0 3QE`OL;n
I 1 1 ( 1 I I 1 1 0 T!*u11 %`` c°i c"'v z
L o
v Z 0 a
M
oa
a` NY mda�
MASONRY TYP.HEAD& 12 JAMBS
�r _
OPENING o
-4 o=
9
C 41
28 FRAME X a Q
_ N° z xz
mo
pOXQ
H NQ
R
E — o m a�
2X BUCK-\ 12 igo
27 TYP.@ JAMB
— TO 1 TYP.
REINFORCEMENT SILL
1 1 1 1 ) i
—^�6'I— SEE HINGE
G SEE NOTE 1 DETAIL o
STRIKE JAMB (TYP-)
0
INSWING PRAMEANCHORLNG HINGE JAMB
S, N Y
E Masonry buck construction d z
CONCRETEANCHORNOTES., `" u O
1.Concrete anchor locations at the comers may be adjusted to maintain the min. w >
? edge distance to mortar joints. c U E �
2.Concrete anchor locations noted as MAX.ON CENTER"must be adjusted to 'a a
maintain the min.edge distance to mortarjoints.additional concrete anchors ¢t�'„W
may be required to ensure the"MAX.ON CENTER"dimension are not exceeded. 28
3.Conaele anchor fable
K 9 =0� Ci
10
ANCHOR ANCHOR tG1IM 1NIN CLEARANCE A CL£ARA,NCf� `='— z
TYPJ $1ZE JEMBEDM�NX 70 MASONRY TOAOJACENT i o
nhO �
2
TAPCON® 1/4" 1-1/4" 2" 4" NOTE l: \ 27 to .�H_z v
ELCO 3/16"x 3-1/4"fTw concrete screw toe-nailed
1 atE 3/7 7/G9 z
i
ULTRACON® 1/4" 1-1/4" 1" 4" through mullion into masonry(each face)at sill �(�� ) Brace: N.T.S. °
F IT{N LATCH d DEAD601TDETAIL HINGE DETAIL U DM er: JK o
® 3/16" 1-1/4" 3" 1-1/2" NOTE 2:
TAPCON No.LFS
#10 X 3 wood screw toe paled through mullion P
WOOD SCREW INSTALLATION NOTES: into masonry(each face)at head
I.Maintain a minimum 5/B"edge distance,)"end distance.&1"o.c.spacing FL-12334.18 0
of wood screws to prevent the splitting of wood.
sir 11 or 13
f
d
t�unur
SEE NOTE 1 O a
z
rrrrll t o n z
V N•;
KZ;
N v z p a
OIL
i OPENNING, TYP.HEAD& a s
JAMBS
28 FRAME Lv(3 c�Lj Vw
h?z o �i
N rl.O
Z
Z p coo
_ Xj
1X BUCK-\
z
27 — OP.@JAMB — TYP.
I
REINFORCEMENT O SILL �� ¢z
0
I 1 l l ( l ( l7 l in
al a
SEE HINGE
G SEE NOTE 1 DETAIL m
(TVP.)
STRIKE JAMBcl
HINGE JAMB12
m
INSWING FRAME ANCHORING a i o
" Masonry 1X buck construction a Z
g CONCRETEANCHOR NOTES: w o
1.Concrete anchor locations at the comers may be adjusted to maintain the min. p
edge distance to mortorjoints. H rr
2.Concrete anchor locations noted as MAX.ON CENTER"must be adjusted to v
maintain the min.edge distance to mortorjoints,additional concrete anchors 'W W
C N V
$ may be required to ensure the MAX.ON CENTER"dimension are not exceeded. 9 a
r;
3 Concrete anchor table., I( 10 _Az
EpM1CLEAANCE ANCffANCHOR M1N z
r
NCHORITW ® 1 4" 1-1/4" 2" 4" n o°
W TAPCON / 27 �� �� wre 3/17/09 ?
ELCO ® -1/4" scva: N.T.S. °
W ULTRACON NOTE l:
F HVI HINGE DETAIL � owc.sr: JK m'
TAPCON® 3/16" 1-1/4" 3" 1-1/2" 3/16"x3-1/4"ITWconcrete screw toe-nailed LATCH&QEADBOLiDETAIL cwc.er LFS 3
E WOOD SCREW INSTALLATION NOTES: through mullion into masonry(each face)at DPAWNG NO.: a
1.Maintain a minimum 5/8" "
"
edge distance.1end distance.&Io.c.spacing head and sill
g P 9 FL-12334.18 a
of wood screws to prevent the splitting of wood. 13
s+¢r 12 of 13
I
81LLOFMATERIALS ````��µtt*�r /////' «
ITEM DESCRII'T10N BELL OF MATERIALS MATERIAL ����' ���
MATERJAL REM DESCRIPAON �y- m
A I BUCK SG>=055 WOOD 50 FIBERGLASS DOOR PANEL w/STEEL REINFORCEMENT(FIBER CLASSIC FIBERGLASS ��
B 2X BU K SG>=0.55 WOOD 51 FIBER CLASSIC DOOR SKIN 0.065"MINIMUM THK.FIBERGLASS FIBERGLASS - K 'Q_ r W
C MAX.1/4"SHIM SPACE COMP. _ = om
52 TOP RAIL �fDi
D 1/4"X 2-3/4"PFH ELCO OR RW CONCRETE SCREW STEEL 54 HINGE STILE
MASONRY-3000 PSI MIN.CONCRETE CONFORMING TO ACI 55 BOTTOM RAIL COMP. '�i�•�• �`` n m
E .301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE 57 LOCK STILE LVL/WOOD �/q/fel�''M+ zn 40 a
G 3116"X 3-1/4"PFH ITW CONCRETE SCREW STEEL 60 FIBERGLASS DOOR PANEL w/STEEL REINFORCEMENT(CLASSIC CRAFT) FIBERGLASS o
H 114'x 3-1/4"PFIi RW CONCRETE SCREW STEEL 61 CLASSIC CRAFT DOOR SKIN 0.065"MINIMUM THK.FIBERGLASS FIBERGLASS g ' Z.a
1 I/4 "x2-1/4"PFH ITW CONCRETE SCREW STEEL 62 TOP RAIL COMP, 'E$ 9Q`°a
J 1/4"X 3.3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL 64 HINGE STILE WOOD
K #8 X 2-1/7'PFH WOOD SCREW STEEL 65 BOTTOM RAIL V
L #10 X 2-1/2"PFH WOOD SCREW COMP. L o
STEEL 67 LOCK STILE LVL/4VOOD
M #10 X 3PFH WOOD SCREW STEEL 70 FIBERGLASS DOOR PANEL w/STEEL REINFORCEMENT CLASSIC CRAFT RUSTIC) FIBERGLASS 8 "R:
1 EXTERIOR LITE FRAME ALUM. 71 CLASSIC CRAFT RUSTIC DOOR SKIN 0.065"MINIMUM THK.FIBERGLASS FIBERGLASS
2 INTERIOR UTE FRAME ALUM. 72 TOP RAIL COMP.
3 LTTE FRAME TRIM PVC 75 BOTTOM RAIL COMP. o
4 #10X 1-1/2"PFH SM SCREW STEEL 77 HINGE AND LOCK STILE WOOD
7 MEDIUM REACH COMPRESSION WEATHER-STRIP FOAM 80 SIDELRE PANEL w/STEEL REINFORCEMENT FIBERGLASS
8 LONG REACH COMPRESSION WEATHER-STRIP FOAM 81 ISIDarrE SKIN 0.065"MINIMUM THK.FIBERGLASS FIBERGLASS J
9 4"X 4"HINGE.097'THK. STEEL 84 STILE AND TOP RAILWOOD M
10 #10 X 3/4"PFH WOOD SCREW HINGE TO FRAME STEEL 85 BOTTOM RAIL WOODS o
" 12 #10 X 7'PFH WOOD SCREW STEEL 86 INSWING SIDELITE ADAPTER PVC c is
17 PASSAGE LOCK-KWIKSETSIGNATURE SERIES STEEL 88 2XMULLION REINFORCEMENT SG>=0.42 WOOD �I m_ o
r 19 HEADER JAMB SG>=0.42 WOOD 89 #9 X 2-1/2"PHi WOOD SCREW STEEL
20 SIDE JAMB SG-0.42 WOOD
21 KWIKSETDEADBOLT-SIGNATURE SERIES 980 STEELm
27 LATCH STRIKE PLATE STEEL 4.56' —�{ j
28 MULTI-POINT STRIKE PLATE STEEL r _�1
ma
!" 32 DOOR BOTTOM SWEEP =PVC oof
33 INSWING THRESHOLD ALUM.COMP. 1 �� o o
35 7/16"Xl/2"STAPLE STEEL
n
S3Y PANELSTEEL 236' W "
40 FIBERGLASS DOOR PANEL w STEEL REINFORCEMENT SMOOTH STAR FIBERGLASS =s
~U N �W
44 HINGE STILE COMP. J9 yp HEAD d SIDE n
Jamb o o
45 BOTTOM RAIL COMP. u
46 INSULATING FOAM CORE POLYURETHANE $H y
47 LOCK STILE LVL/WOOD
48 TOP RAIL COMP.
49 SMOOTHSTAR DOOR SKIN 0.065'MINIMUM THK.FIBERGLASS FIBERGLASS r 5&� w i
i nno
NOTE:WOOD/LVL COMPONENTS: PINE(SG>=0.42) - m
atc: 3/77/09 z
sour: N.T.S.
INSWING °N0.or. JK m
T33
hreshold aa.BY: LFS 3
DRAMNG NO.: It
FL-72334.18 0
stw 13 or 73