Loading...
HomeMy WebLinkAboutProduct Approval v ionaa isunamg Loae unlllne rage t or 4 � �: SCIS Home I Log In I User Registration Hot Topics I Submit Surcharge Stats&Fads Pubfiations i FBC Staff I BaS Shm Map upt. I Search Florida - ` "¢ Product Approval _- USER:Public User r 7.",sold�F:tit Product Approval Menu>Product or Application Search>Application Lis >Application Detail ° FL# FL14608-116 Appiliation Type Cditmal Change Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or,the Commission If necessary. Comments r Archived Cl Product Manufacturer Eastern Architectural Systems Address/Phone/Email 16341 Domestic Ave. Ft.Myers,FL 33912 (800)432-2204 Ext 4305 jflesher@easternmetal.com Authorized Signature James Flesher jflesher@easternmetal.com Technical Representative Timothy J.Hoard Address/Phone/Email 10030 Bavaria Road Fort Myers,FL 33913 (800)432-2204 Ext 4314 thoard@easternmetal.com Quality Assurance Representative ft.5.s/Phone/Email Category Windows Subcategory Fixed Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2005 AAMA/WDMA/CSA 101/I.S.2/A440 2008 ANSI/AAMA/NWWDA 101/I.S.2 1987 ASTM E1886 2002 ASTM E1886 2005 ASTM E1996 2009 ASTM.E1996 2-002 TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By h4.11www.flolidabuilding.Qrg/pr/pr app_dtl.aspx?param=wGEVXQwtDgswgZVNfs8A7... 7/2612017 Florida Building Code Online Page 2 of 4 i' Product Approval Method Method 1 Option A Date Submitted 05/24/2017 Date Validated 07/12/2017 Date Pending FBC Approval Date Approved 07/13/2017 Summary of Products FL# Model,Number or Name Description 14608.1 Series"1000"Aluminum Non- Series"1000"Aluminum Non-Impact Fixed Window Impact Fixed Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL14608 R6 C CAC NI006122.01-R2-5igned.pdf Approved for use outside HVHZ:Yes FL34,QQ8..R6 G.AG_.N.j.QQf12, Q,.R.].- ig0.e�,.Rdf Impact Resistant:No Quality Assurance Contract Expiration Date Design Pressure: +130.0/-130.0 12/31/2019 Other: Maximum Size: 60"x 48". Monolithic or Insulated Installation Instructions glass FL14608 R6 II 08-02393A.pdf Verified By: Luis R. Lomas, P.E.Florida P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14608 R6 AE 51Q -6._A.pdf Created by Independent Third Party: Yes 14608.2 Series"1500"Aluminum Non- Series"1500"Aluminum Non-Impact Fixed Window Impact Fixed Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL14,§08 i26.C__GAC„NI006176�OS�R2,- igngd,,pdf Approved for use outside HVHZ:Yes FL14608 R6 C CAC NI006176.04-111-signed,pdf Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +125.0/-125.0 04/30/2020 Other: Maximum Size: 96”x 48". Monolithic or Insulated Installation Instructions glass FL14608 R6 II 08-02394A.odf Verified By: Luis R. Lomas, P.E. Florida P.E.62514 Created by Independent Third Party: Yes Evaluation Reports FL14608 R6 AE 513167.pdf Created by Independent Third Party: Yes 14608.3 Series"FWI 2000"Aluminum Series"FWI 2000"Aluminum Impact Fixed Window Impact Fixed Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14608 R6 C CAC NI009023.01-R3-signedpdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 02/28/2021 Design Pressure: +90/-90 Installation Instructions Other: Maximum Size: 144"x 48" FL14608 R6 II 08-02395A.odf Verified By: Luis R. Lomas,P.E. Florida P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL146Q8 R6 AE 513168A..p�Jf FL1460$,_U_AE f�QA,_14=0_4,_2_1¢,PDF Created by Independent Third Party: Yes 14608.4 Series 1436 Vinyl Non-Impact Fixed Series 1436 Vinyl Non-Impact Fixed Window with Nailing Fin Window with Nailing Fin Limits of Use Certification Agency Certificate Approved for use in HVHZ: NoFL1$�C08 R6 C CAC NI01060 gweed.Pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 07/31/2019 Design Pressure: +80/-80 Installation Instructions Other: Maximum Size: 71 1/2"x 71 1/2". Frame material EL146Q8.R6 II Q>3_QQ.55. C pdf to be rigid PVC from Deceuninck North America AAMA Verified By: Luis R. Lomas,P.E.Florida P.E.62514 Certified(DEP-1) Created by Independent Third Party: Yes Evaluation Reports L1460 R AE1Q,4�6A.pf Created by Independent Third Party: Yes 14608.5 Series 1446 Vinyl Non-Impact Fixed Series 1446 Vinyl Non-Impact Fixed Window with Flange Window with Flange -http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A7... 7/26/2017 Florida Building Code Online Page 3 of 4 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No F"46QQ R6 C -CAC. r(IQ1 6 3-M.&jzsjgned.ndf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 07/31/2019 Design Pressure: +80/-80 Installation Instructions Other: Maximum Size: 74 1/2"x 72". Frame material to be FL14¢Q8 R6 II Q8 .Q.5 rigid rigid PVC from Deceuninck North America AAMA Certified Verified By: Luis R. Lomas,P.E. Florida P.E.62514 (DEP-1) Created by Independent Third Party: Yes Evaluation Reports EL34608 R6 AE 510948B.Ddf Created by Independent Third Party: Yes 14608.6 Series 176 Vinyl Impact Fixed Series 176 Vinyl Impact Fixed Window with Flange HVHZ Window with Flange HVHZ Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL §Q5 _CAG...N.I•Q11878 Q1 R2.,.pdf 1� Approved for use outside HVHZ:Yes FL14608 R6 C CAC N1011878-R2.pd Impact Resistant:Yes FL14608 R6 C CAC NI011879.01-R2.Ddf Design Pressure: +80.0/-80.0 FL14608 R6 C CAC NI011879-R2.pdf (A Other: Maximum Size: 72"x 63". Frame material to be Quality Assurance Contract Expiration Date rigid PVC from Deceuninck North America AAMA Certified 01/31/2022 (DEP-1).WHEN INSTALLED IN THE HVHZ THIS PRODUCT IS Installation Instructions TO BE INSTALLED AT 30'OR LESS ABOVE GROUND LEVEL. 5014, Q.Q_R(._I _,•Q -,Q2,z.Q4B;.p,_f Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14608 R6 AE 513043B.pdf FL14608 R6 AE Kurarary SGP NOA 14-0916.11.PDF Created by Independent Third Party: Yes 14608.7 Series 176 Vinyl Impact Fixed Series 176 Vinyl Impact Fixed Window with Flange HVHZ Window with Flange HVHZ Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14608 R6 C'CAC NI011_880 01-R2 Ddf Approved for use outside HVHZ:Yes FL14608 R6 C CAC NI011880-R2 Ddf Impact Resistant:Yes FL1460a R6 C CAC NI011881.01-R2Lpdf Design Pressure: +80.0/-80.0 5114.¢06_ R6 C._..C.9G._.NI,Q,1_l,$81•-. 2p1 Other: Maximum Size: 72"x 84".Frame material to be Quality Assurance Contract Expiration Date rigid PVC from Deceuninck North America AAMA Certified 01/31/2022 (DEP-1) Installation Instructions FL14608 R6 II 08-02293B.pd Verified By: Luis R. Lomas,P.E.62514 Created by Independent Third Party: Yes Evaluation Reports FL14608 R6 AE 5130428 Ddf 5114608 R6 AE KurPra.ry—SGP NOA 14 Q916,ll.PDF Created by Independent Third Party: Yes 14608.8 Series 2456 Vinyl Impact Fixed Series 2456 Vinyl Impact Fixed Window with Nailing Fin Window with Nailing Fin Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL14608 R6 C CAC NI010610-Rl-signed pdf Approved for use outside HVHZ:Yes FL14608 R6 C CAC NI010656-R1-signed.Ddf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: +50/-50 09/30/2019 Other: Maximum Size: 64"x 84". Frame material to be Installation Instructions rigid PVC from Deceuninck North America AAMA Certified FL14 R6 II 08-OQ$63C.P-df (DEP-1) Verified By: Luis R. Lomas, P.E. Florida P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14.4Q8 R6._A_E 51_Q�.�2A:pdf FL14608 R6 AE NOA 14-0423.15.PDF Created by Independent Third Party: Yes 14608.9 Series 2466 Vinyl Impact Fixed Series 2466 Vinyl Impact Fixed Window with Flange Window with Flange Limits of Use Certification Agency Certificate Approved for use in HVHZ: NoFL14.508�25 G CAC_NI010(10_Q1^Rjj5jgngd,pdf Approved for use outside HVHZ:Yes FL14608 R6 C CAC NI010656.01-Rl-signed_pdf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: +60/-60 09/30/2019 Other: Maximum Size: 64"x 84". Frame material to be Installation Instructions rigid PVC from Deceuninck North America AAMA Certified FL14608 R6 II 08-00565C.pdf (DEP-1) Verified By: Luis R. Lomas,P.E. Florida P.E, 62514 Created by Independent Third Party: Yes Evaluation Reports FL14608 R6 AE 519`4Bpdf F.L JA6.Q OL RCLAE_fyQA„_14=0423.15.PD,F Created by Independent Third Party: Yes http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEV XQwtDgsw8ZVNfe 8 A7... 7/26/2017 j 7 1 I i REVISIONS ,} REV DESCRIPTION DATE APPROVED A REMOVED FLUSH INSTALLATION 07/23/14 R.L. 8 REVISED INSTALLATION DETAILS 065/23/15 R.L. NOTES: 15. FOR ANCHORING FRAME INTO WOOD FRAMING OR 2X BUCK USE #14 WOOD SCREWS WITH 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH SUFFICIENT LENGTH TO ACHIEVE A 1 7/16" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE REQUIREMENTS OF THE FLORIDA BUILDING CODE INCLUDING THE HVHZ. ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY 16. FOR ANCHORING FRAME INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE DETAILS. ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED 17. FOR ANCHORING FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 18. ALL FASTENERS TO BE CORROSION RESISTANT. 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY 19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM 'STRENGTH SPECIFIED BELOW: MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. A. WOOD - MINIMUM SPECIFIC GRAVITY OF G=0.42 6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED B. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI. COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF C. MASONRY - STRENGTH CONFORMANCE TO ASTM C-90, GRADE N. TYPE 1 (OR GREATER). THE ARCHITECT OR ENGINEER OF RECORD. D. METAL STRUCTURE: STEEL 18GA, 33KSI OR ALUMINUM 6063-T5 1/8" THICK MINIMUM 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS 20.GEOMETRIC SHAPES ARE ALSO APPROVED_ APPROVED GEOMETRIC SHAPES DIMENSIONS PROVIDED. SHALL NOT EXCEED INSCRIBED DIMENSIONS OF APPROVED RECTANGULAR ASSEMBLY SHOWN 8. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT IN SHEET 2. GEOMETRIC SHAPES ARE NOT LIMITED TO SHAPES SHOWN HEREIN. EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. - 11. FRAME MATERIAL: EXTRUDED RIGID PVC. 12. UNITS MUST BE GLAZED PER ASTM E1300-04, SEE SHEET 2 FOR GLASS OPTIONS. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING FIN INTO WOOD FRAMING OR 2X BUCK USE #8 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. SIGAED:.067/24/2015 EaS`f` FASTERN.iRGIRECMULSYSfENS j�ILtJl1 ■ n v n« PMUYEFM nov=a TABLE OF CONTENTS SERIES 176 PW FIXED WINDOW IMPACT HVHZ 0,; 51, Tt� 72" x 63" SHEET NO. DESCRIPTION �� NOTES ��C. 46 TSOF. 1 NOTES DRAWN: DWG NO. REV 2 ELEVATIONS AND GLAZING DETAIL SCALE DATE 08-02294 B ,/17%�Q►�(A„ \�\\ 3 - 5 INSTALLATION DETAILS NTS 02/23/14 1 OF 5 REVWNS REV DESCRIPfgN DATE APPROVED A REMOVED FLUSH INSTALLATION 07/23/14 R.L. B REVISED INSTALLATION DETAILS 06/23/15 R.L 73 1/4" MAX TIP TO TIP WIDTH 72" MAX OA WIDTH 72" MAX OA FRAME WIDTH 6" MAX MAX D.C. 6" MAX 2" MAX 12D. .MAX 2• KM 6" MAX �- 12" MAX MAX 9 1/2" / TIP / TO MAX O.C. TIP T - / 63" 63" MAX MAX o.a A / HEIGHT / FRAME HEIGHT 6" MAX 1 SERIES 176 PW FIXED WINDOW SERIES 176 PW FIXED WINDOW FRAME INSTALLATION EXTERIOR VIEW FIN INSTALLATION EXTERIOR VIEW DESIGN PRESSURE RATING IMPACT RATING +80.OPSF LARGE 1• MISSILE IMPACT 1/8" HS MISSILELEVELD,WIND ZONE4 AND HVHZ 3/16" HS .090 SENTRYGLAS BY DUPONT 1/8" HS SIGNED:0612412015 EXTERIOR INTERIOR "" +'+�`i �'"5 GLAZING QUANEx DURASEAL :� Eastern, * • `\\�`S P.Irt10I!/��� BEAD SPACER SYSTEM v: t(',E4S+ "9�-q�/� 2��SaSIKAFLEX 1/2" BITE 552 SERIES 176 PW FIXED WINDOW IMPACT HVHZ �* 0 _ uv 72" x 63" .: ELEVATIONS AND GLAZING DETAIL hyo 7AT � �0. DRAWN: DWG NO. REV i�'cFs.;c1,pR1�4:G� SETTING BLOCK GLAZING DETAIL .LL 08 5027294 8 ✓<77S�pNA l`�\\� NTS �� 02/23/14 2 OF 5 5/8" MIN. REVISIONS EDGE DISTANCE EDGE DISTANCE 1" MIN. REV DESCRIPTION DATE APPROVED WOOD FRAMING METAL A REMOVED FLUSH INSTALLATION 07/23/14 R.L. OR 2X BUCKSTRUCTURE B REVISED INSTALLATION DETAILS 06/23/15 R.L. BY OTHERS 1 7/16" MIN. BY OTHERS EMBEDMENT rol I------— METAL 11/4" MAX. STRUCTURE SHIM SPACE ff1��FyI (} 1/4" MAX. BY OTHERS APPROVED °UU� 1/4" MAX. �-° SHIM SPACE #10 SMS OR SEALANT SHIM SPACE BEHIND FLANGE APPROVED SELF DRILLING O SEALANT SCREWS ° BEHIND FLANGE #14 SMS OR INTERIOR #14 WOOD SELF DRILLING ° SCREW SCREW 1" MIN. EDGE DISTANCE a�Q APPROVED EXTERIOR SEALANT BEHIND FLANGE JAMB INSTALLATION DETAIL INTERIOR EXTERIOR INTERIOR METAL STRUCTURE INSTALLATION EXTERIOR 1 7/16" MIN. EMBEDMENT 1/4" MAX. #14 WOOD SHIM SPACE SCREW 5/8" MIN. /7 �0 EDGE DISTANCE o Q �_ ° INTERIOR #14 SMS OR APPROVED SELF DRILLING #14 WOOD APPROVED SEALANT SCREW SCREW Q n11 -/A " W BEHIND FLANGE BEHINDSEALANT ° MAX FRAMING FLANGE ° I Ia0 SHIM SPACE METAL ° SHIM SPACE OR 2X BUCK u U STRUCTURE BY OTHERS WOOD FRAMING t BY OTHERS EXTERIOR OR 2X BUCK 1 7/16" MIN APPROVED BY OTHERS SEALANT JAMB INSTALLATION DETAIL EMBEDMENT BEHIND FLANGE WOOD FRAM/NGOR 2X BUCK INSTALLATION 1" MIN. 5/8" MIN. EDGE DISTANCE SIGNED 06/24/2015 EDGE DISTANCE ens w,.no sc wKs arcus VERTICAL CROSS SECTION VERTICAL CROSS SECTION a�4 Eastern � � \ g R I IL p �ii� WOODFRAM/NGOR2XBUCK/NSTALLATION METAL STRUCTURE INSTALLATION e.. - �e�m.��oo,�s'rcAVE �, Eom urcAs.noaoA r�,v�tfilVs •'�S•�� SERIES 176 PW FIXED WINDOW IMPACT HVHZ AkFP04F-M'!,k, NOTES: 72" x 63"1.INTERIOR ANDEXTER10RF1NISHES,BYOTNERS, FLANGE INSTALLATION DETAILS ��0 NOT SHOWN FOR CLARITY. owcNo2.PERIMETER AND JOINTSEALANT BY 18STOBE REV OSIGNEDINACCORDANCEWITHASTME21JL 08-02294 0�..��. A••,�k!`� i�/FSS NAA SCALE NTS DATE 02/23/14 SHEETS OF 5 ///�QNAi, ��\� 2 1/2" MIN. REVISIONS ^ EDGE DISTANCE REV DESCRIPTION DATE APPROVED CONCRETE/MASONRY A REMOVED FLUSH INSTALLATION 07/23/14 R.L. BY OTHERS a e REVISED INSTALLATION DETAILS 06/23/15 R.L. a' a 1 1/4" MIN. OPTIONAL 1X BUCK ` " 'd. ••a EMBEDMENT SEE NOTES 3-7 SHEET 1 1 1/4" MIN 0 , } EMBEDMENT CONCRETE/MASONRY APPROVED ❑ 1/4" MAX. BY OTHERS SEALANT OPTIONAL 1X BUCK SHIM SPACE °v 1/4" MAX. SHIM SPACE BEHIND FLANGE rf7l SEE NOTES 3-7 SHEET 1 ° U 3/16" TAPCON 3/16" TAPCON a INTERIOR c El 2 1/2"MIN. a veau EXTERIOR INTERIOR EDGE o 0 DISTANCE APPROVED SEALANT EXTERIOR BEHIND FLANGE 3/16" TAPCON JAMB INSTALLATION DETAIL n CONCRETEIMASONRY INSTALLATION APPROVED �J SEALANT BEHIND FLANGE1/4" vU OPTIONAL 1X BUCK o SHIM MAX. SPACE NOTES: SEE NOTES 3-7 SHEET 1 �p 1.INTERIORAND EXTERIOR FINISHES,BYOTHERS, NOT SHOWN FOR CLARITY 0 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE CONCRETE/MASONRY _� DESIGNED IN ACCORDANCE WITH ASTM E2112 '.° • SIGNED:06/24/2015 BY OTHERS • n a 1 1/4" MIN. *�+ +�^^�+ �ttlllllj • • = Eastern ADNSONOF \.`g•R co z a� EMBEDMENT F,vSrwauET.0 svcir 7 a <• 2 1/2" MIN. SERIES 176 PW FIXED WINDOW IMPACT HVHZ 72' x 63" EDGE DISTANCE FLANGE INSTALLATION DETAILS ¢f� TAT OF t4. SCALE NTS DATEowNO.CICROSS L 0+1RtttECO RETEMASOY/NSTALAO j 08-02294 S/O ,1102/23/14 SHEET4 OF `\ 5 REVISIONS -- I REV DESCRIPTION DATE APPROVED A REMOVED FLUSH INSTALLATION 07/23/14 R.L. 8 REVISED INSTALLATION DETAILS 06/23/15 R.L. APPROVED SEALANT BEHIND FIN 1 1/4" MIN. EMBEDMENT #8 WOOD WOOD SCREW FRAMING BY OTHERS 1/4" MAX. WOOD FRAMING .{ 1/4" MAX F SHIM SPACE BY OTHERS I SHIM SPACE 7/16" MIN EDGE DISTANCE INTERIOR � o0 1 1/4" MIN. EMBEDMENT EXTERIOR INTERIOR �Q #8 WOOD SCREW APPROVED SEALANT EXTERIOR BEHIND FIN 7/16" MIN EDGE DISTANCE JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION 1/4" MAX NOTES: SHIM SPACE 1.INTERIOR AND EXTERIOR FINISHES,BYOTHERS, NOT SHOWN FOR CLARITY. 2.PERIMETER AND JOINT SEALANT BYOTHERS TO BE 7/16" MIN j DESIGNED INACCORDANCEW/7HASTME2112 EDGE DISTANCE #8 WOOD WOOD SIGNED:05/24/2015 SCREW FRAMING APPROVED EM EDMENT BY OTHERS EaStel`I1 \�\��S 10114 VERTICAL CROSS SECTION ., SEALANT A,,,,,a.',',•„y�'�` •^"' 'i-oRrurrns.no-m=2 BEHIND FIN WOOD FRAMING OR 2X SUCK INSTALLATION SERIES 176 PW FIXED WINDOW IMPACT HVHZ Z_ o $T 72" x 63" FW INSTALLATION DETAILS =p ?OF DRAWN: DWG NO. REV �F!�1OR��4`:.: \ SCALE Dare 08 02294 8 NAL NTS 02/23/14 1 SHEET 5 OF 5 M. SCIS Iiome iogdn ( UserReoswa ipn IictTopics Sut;e*surchaMe Stats&Facts %br=uDns pBc Soff .005 site Map i Unks � Search F! dda Product Approval sA BSER:public User d, ` Product Approval Menu>Rroduct or Application search>Application List>Appitcation Detail REMFL# FL16412-112 Application Type Revision Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission If necessary. Comments Archived Product Manufacturer Eastern Architectural Systems Address/Phone/Email 16341 Domestic Ave. Ft.Myers,FL 33912 (800)432-2204 Ext 4305 jflesher@eastemmetal.com Authorized Signature James Flesher jflesher@easternmetai.com Technical Representative Timothy J.Hoard Address/Phone/Emali 10030 Bavaria Road Fort Myers,FL 33913 (800)432.2204 Ext 4314 thoard@easternmetal,com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) StandaEd Year AAMA/WDMA/CSA 101/I.S,2/A440 2005 AAMA/WDMA/CSA 101/I.S.2/A440 2008 ASTM E 1886 2005 ASTM E1996 2005 ASTM E 1996 2009 TAS201 1994 TAS202 1994 TAS203 1994 Equivalence of Product Standards Certified By hq-//wIrv.floriclabuilding..arg/pr/pir app_dtLasFx?garam=WGF,VXQWtDgVXaHHDWAAyb.6.gTr-iQEQV.doF%2.,. 6/7/2.017 1 ar'G 4 V1 4 Product Approval Method Method 1 Option A Date Submitted 09/28/2016 Date Validated 09/29/201, Date Pending FOC Approval Date Approved 10/02/2016 Summary of Products FL# Model,Number or Name Description 16412.1 176 Vinyl Impact Single Hung 176 Vinyl Impact Single Hung L colts of Use Certification Agency Certifscate Approved for use in HVHZ:Yes FL16412 R2 C CAC NI012195 odf Approved for use-outside HVHZ:Yes Quality Assurance Contract•Expiration Date Impact Resistant:Yes 06/30/2018 \� Design Pressure:N/A installation Instructions \ other:Design Pressures are as follows:Fln Window FL16412 R2 fi 08-02538A.pdf 0 +70.0/-85.0psf,Flange Window+70.0/-85.0psf.Maximum Verified By:Louis R.Lomas,P.E.62514 Size:54"x 77".Frame•Material.to be Rigid-PVC From Created by Independent Third Party:Yes Deceuninck North America AAMA Certified(DEP-1) Evaluation Reports FL16412 R2 AE 13-0328 09-COMP odf FL16412 R2 AE 13-0328.09 Dupont SentryGlas odf FL16412 R2 AE 513311A.odf Created by Independent Third Party:Yes 16412.2 Series HD2451/Series.HD2461 Series.HDZ451/Ser1es.HDZ461 Vinyl Impact Single.Hung Single Hung Limits of Use Certification Agency Certificate Approved for use In HVHZ:No FL16412 R2 C CAC NI01153 -Rl-signed.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 09/30/2018 Design Pressure:+65.0/-65.0 Installation Instructions otl1w.:Maximum Size:44".x 84",Nailing fin or Flange Frame. FL16412 R2 11 08-01933A.pdf Frame Material to be Rigid PVC From Deceuninck North Verified By:Luis R.Lomas,P.E.62514 America AAMA Certified(DEP-1) Created by Independent Third Party:Yes Evaluation Reports FL16412 R2EtE-512641A odf FL16412 R2 AE NOA Safiex PVB 15-1201.11.pdf Created by Independent Third Party:Yes Back Next Contact U, g1 Blair Stone kgad,Talla pssee,[L 3 399 Phone:850.467.1824 The State of Florida Is an WEED employer.Copyright 2007-2013,State of Florida ::Privacy Statement::gcessiblii Statement::Refund Statement Under Florida law,emall addresses are public records.If you do not want your e-mail address released in response to a publlc-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.if you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please dick here. ArAdu.,�ctAPPMAi Acs PW IN 9 Credit Card Safe MEN= http://www.floridabuikling.org/prlpx�_appMI.. 617/2037 REVISIONS REV DESCRIPTION I 0.Tc APPROVED ARE`/ISEO IN57ALLAION OETAII.S 06/23;'75 R.L. - NOTES: 15. FOR FRAME ANCHORING INTO WOOD FRAMING: OR 2X BUCK USE 410 WOOD SCREWS WITH 1. THE PRODUCT SHOWN HERE.N IS DESIGNED AND MANUFACTURED TO COWILY.•'WITH REOUiREMEMS OF THE FLORIDA SUFFICIENT LENGTH TO ACHIEVE A 1 1/4 MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE BUILDING CODE INCLUDING THE HVHZ. ANCHORS AS SHO:JN IN'ELEVATIONS AND INSTALLATION DETAILS. 2. WOOD FRAMING AND MASONRY' OPENING TO 8E DESIGNED AND ANCHORED'-TI4E,PROPERLY 16 TOR FRAM^ ANCHORING INTO MASONRY CONCRETE USE 3 :6" TAPCONS WITH SUFFICIENT TRANSFER ALL LOADS TO STRUCTURE- FRAMING AND MASONRY OPENING iS.'THE. / RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF'RECC+RD. LENGTH T0.ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS.MUST BE DETAILS. ANCHORED.THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED 17. FOR FRAME ANCHORING INTO MEAL -STRUCTURE USE 111.0 SMS OR SELF DRILLING SCREWS INSTALLATION INSTRUCTIONS. ANOHGRS,SHALL BE SECURELY FASTENED DIRECTLY INTO WITH SUFFICIENT LENGTH T0,ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR MASONRY, CONCRETE OR OTHER STRUCTURAL.SUBSTRATE MATERIAL WALL LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 5 18. ALL FASTENERS TO BE CORROSION RESISTANT- WHERE WOOD BUCK THICKNESS IS 1—i/2- OR GREATER, BUCK SHALL BE SECURELY 19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCOPIANC€ `WTH ANCHOR FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS \JAY MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL. NOT BE USED IN BE ANCHORED THROUGH FRAME TO SECURED WOOD'BUCK IN ACCORDANCE WITH SUBSTRATES WITH STRENGTHS LESS THAN THE /;INIr%UM STRENGTH SPECIFIED BELOW: MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. A WOOD — MINIMUM SPECIFIC, GRAVITY OF C=0.42 6. WHERE TX BUCK IS NOT U_=.ED (DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROvED B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH 07 3.132 PSI. COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF C. MASONRY-- STRENGTH CONFORMANCE TO ASTM C-90, GRADE N. TYPE 1 fOR GREATER). THE ARCHITECT OR ENGINEER OF RECORD. D. METAL STRUCTURE: STEEL 'SGA. 33<SI OR ALUMINUM 3053—T5 1/8" THICK :dINl1 UEJ 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS 20.UNITS MAY BE INSTALLED WITH OR WITHOUT FLAN:X OUTSIDE THE H-HZ- PROVIDED. E. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM, AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/15' LIR GREATER OCCURS. MAXIMUM ALL•rWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATCO, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLL OF SUSTAINING APPLICABLE LOADS. 10. WINO LOAD DURATION ':ACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED RIGID FVC. 12. UNITS MUST BE GLAZED PIER ASTM E1300-04, SEE SHEET 2 FOR CLASS OPTIONS. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS ;REGIONS. 14. FOR FIN INSTALLATION INTO •`.FOOD FRAMING OR 2X BUCK USE j10 WOOD SCREWS '1JITH _ .SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN 114 ELEIVATiONS AND INSTALLATION DETAILS. SIGNED.06/2.412015 Eastern `,�,`�R. r p z �., .� ' GENS. TABLE OF CONTENTS 176 SH VINYL SINGLE HUNG WINDOW *� 0 7 SHEET NO. DESCRIPTION IMPACT 54" X 77" NOTES 7D'' S7�1T�OF NOTES ELEVAlFIONS "Ev 4 — 7 INSTALLATION DETat S ` NTS -'c 11/17/14 08-02538 1 OF 7 A 54" MAX FRAM: WIDTH . REVISIONS REV DESCRIPTION. mTE APPROVED 6" 1+1 X MAX 4O.C. 6" MAX A R-MSEC INSTALLAON DETAILS b6J23/i5 R.L. 6 MAX OHARDWARESCHEDULE 13" / MAX O.C. A. (4)ASHLAND DUAL KEEPERS(13959).ATXEEPERRAIL&'FROM EACH JAMB / B. (4)ASHLAND DUALLOCKS(D1100AL/R)AT KEEPER RAIL 8-FROM EACH JAMB C. (2)CALDWELL COIL BALANCESYSfEM(880)ONE ATEACH JAMB 77 D. (2)CALDWELLTILT LATCH(20000p41)11%2"FROM EACH SASH TOP RAIL CORNER FRPdE (— E (2)CALDWELL PIVOT BAR(16VS13)ONEATEACH END OFOPERABLE SASH BOTTOM RAIL ' HEIGHT 1/8" ANN. I .090" SENTRYGL;:S BY DUPONT3!16" ANr!. li&" aNN. / GLAZING BEAD—\ - DuP.A—SEAL / I SPACER SYSTEM. 6 MAX /�j -- ^ INTI=RIOR . EXTERIOR l'I' SIKP.FLEX 552 SERIES 176 SH_VINYL SINGLE HUNG WINDOW SETTING BLOCK SEALANT EMRIOR VIEW GLAZING DETAIL FIN INSTALLATION DESIGN PRESSURE RATI111G IMPACT R477NG +70.01-85.OPSF LARGE MISSILE IMPACT MISSILE LEVEL D,WIND ZONE 4 AND HVHZ SfGNED_06/24/2015 FATTE1tN MC"R EC fu1GL SYSiFAg ��� A OmaonoE ��l Eastern ��NE,K�n. ,.��s R- oNOTES: '�%, 1. MAXIMUM SASH SIZE. 50 3/8" X 37 3/4•. ,�:�.".._." "�..... �. eoo.a�nAVE. .`�\`JEIVq .s.....,...:..wo vo wv� 1-1 urERS.natmA3lGu. j 2. MAXIMUM D.L.O.: 49 1/8" X 34 3%4". SERIES 176 SH VINYL SINGLE HUNG WINDOW �yr�'�1 3. (2) WEEPS WITH COVER (47—G3) AT SILL FACE 2" FF.OM EFa=H CORNER. IMPACT 54" X 77" ' 4 (2) I 1/2" X 1/4" Y'EEP SLOT AT SILL PACE 2" FROM EACs. CORNER. ELEVATIONS �- .�� ��. TATE OF 5. (2) 1/2 X 1/8" WEEP SLOT AT SILL BEHIND GLI A21NJ LEG. �0. oRAv,,; eecNo. Rev �iF C01WOP.���. SG'•:E NTS DANE 11/17/14 08-025280E 7 A i/NAj1��G` �� P . RFVFJONS . .. REV OESCRIP.,TI:r. DATE AMMIED .:. 54- MA)e FRAME WIDTH A REVISED INSTALAT104 bETMLS I Do/23ji5 R.L. 54 MAX FRAME S11DTH ---'---------- f4 10" o' MAX MAX O.C. r 6" MAX 6 MAX MAX 6" MAX 6: MAX o" MAX ,y11aX�0.�. ..0 :5" Mt O.C. 774' / 77" MAX __ MAY.. FRAME FRAME, HEIGHT I HEfGHT i i 1 6" MAY 5" MAX t- SERIES 176 SH VINYL SINGLE HUNG WINDOW SERIES 176 SH VINYL SINGLE HUNG WINDOW EXTERIOR VIEW EXTERIOR VIEW THROUGH FRAME INSTALLATION THROUGH FRAME INSTALLATION FOR MASONRYAND METAL STRUCTURE FOR WOOD FRAMING DESIGN PRESSURE RATING IMPACT RATING +70.01-85 OPSF LARGE MISSILE IMPACT MISSILE LEVEL D.IN/ND ZONE 4 AND HVHZ SIGNED.06/24MO 15 ewsrEraJwaarcerurK srsreJAs ````S to o�//' � /i ►' wom9anor RC1. fI! �- Eastern , �YK n�•L•:d 'ro'aiurE�Rs'n�oR�a SERIES 176 SH VINYL SINGLE HUNG WINDOW _fir• p. yt= IMPACT SI TAT OF X 77" =,o'�G ELEVATIONS �o_ DRAWN: GYJj NO. kEV ��••��Z� -` N.G. 08-02538 A �Rt� G;`�� SCALE NTS -E 11/17/14 1$"'L 3 OF 7 REMSONS ONS 1/2" MIN. RV DESCRIPTION ' MTE nPPRG�EU -r�EDGE DISTANCE A REVISED INSTALLATION DETAILS 06/23) WOOD FRAMING �------ OR 2X BUCK BY OTHERS 1 1./47 MIN. EMBEDMENT it BACKER RODdO�n & APPROVED SHIM.SPACE 1 1/4" Fd;N. i/4" MAX. SEALANTIL �F,tBEGM=NT SHIM SPACE ' i g rI I . iy INTERIOR 0 WOOD SCRE L 5 j2" tr11M. EDGE DISTANCE 1 OHO EXTERIOR i + i I n 0 ViO0; 1 0 SCREsv / j 1 I ;FOOD FRAMING OR 2X BUCK �c INTERIOR BY OTHERS G� II' I!I L SACKER ROD EXTERIOR I ( & APPROVED SEALANT i JAMB INSTALLATION DETAIL D WOOD FRAMING OR 2X BUCK INSTALLA77ON Ii I ( of SILL TO BE SET IW A BED OF �� APPROVED SEALANT BACKER RODL `. & APPROVED I 1/4" MAX. SEALANT 1 I , SHIM SPACE - WOOD FRAMING OR 2X BUCK BY OTHERS SIGNED.06/24/2015 VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLA77ON lie A— o R"4 X 9 NOTES: SERIES 176 SH VINYL SINGLE HUNG WINDOW 1.INTERIOR AND EXTERIOR FINISHES.BYO7HERS, IMPACT 54" X 77"INSTALLATION DETAILS NOT SHOWN FOR CLARITY. �P. TAT OF �O 2.PERIMETER AND JOINT SEALANT BYO7HERS TO BE DaFwv. D.,r.��• RLy i'.c�..c(ORI�P•\�\` DESIGNED INACCORDANCE WITH ASTM E2112 N.G. 08-02538 A TSS Sc4tE NTS UnTM 11/17/14 S11EET4 OF 7 r F— VA MIN, rtEv CES "p-N. OrTE VaROVED METAL i EDGE DISTANCE ' I —r.' A -REVISEC WSTALU+TION DETAILS L06%23115 R.L. STRUCTURE —• BY OTHERS 1/4" MAX. SHIM..SPACE APPROVED' L1Ca SEALANT to J� #10: SMS OR . U' SELF DRILLING SCREW 1/4" MAX. —j SHIM SPACE I. I INTERIOR EDGEDISTANCE J 5 I R1(1'SMS OR 1 R SELF'DRILLING I ��-- [� SCREWS EXTERIOR a i INTERIOR METAL i I BYOTHERSi G • BACKER ROD -1 EXTERIOR i & APPROVED II r SEALANT n iH i u SILL TO� BE SET A BEG OF IQ I APPROVED SEALANT JAMB INSTALLATION DETAIL PJCKEP. ROD t METAL STRUCTURE INSTALLATION APPROVED L SEALANT — a '1/4' MAX. SHIM SPACE METAL (� t STRUCTURE BY OTHERS VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION SIGNED.06/24/2015 FASfERNaRCM1ECTUILILSYLiEaG �1lfllflly' - Eos ern °^ K .��5 R. i o zCAW � ioar urEas.aomm�avtt `r�•'�C.E N'S. cS'�� .t�'�'""^ ero.aaa V Ll". NOTES: SERIES 176 SH VINYL SINGLE HUNG WINDOW *' MOF-m 1.INTERIOR AND EXTERIOR FINISHES. IMPACT 54" X 77" BYOTHERS,NOTSHOWN FOR CLARITY. INSTALLATION DETAILS S ��t�= DESIGNED IN ACCORD2.PERIMETER AND ANCE WITH ASTM E21NT BY OTHERS TO BE G.: ^, REQ/ ��j��:cLOR10P G scyE oar OS-OE538 A ��/;YONA`l�� NTS 11/17/14 5 OF 7 i CONCRETE/IdASONRY REASONS _I 2 1/2" MIN. BY OTHERS REV DESCRIeTIGN. I DATE APPROVED EDGE DISTANCE A REVISEQ INSTALLATION�DETNLS* 0E/23/15 R.L. ° e 1 i/4" MIN. EMBEDMENT EMBEDMENT ' I CONCRETE/MASON.RY OPTIONAL 1X BUCK Jo �Do BY OTHERS ' SEE NOTES 3 — 7 O 1/a" MAX. " SHEET 1 j SHIM SPACE OPTIONAL 1X BUCK ! —� t/4" MA<. SEE NOTES 3 - 7 I' I I SHIM SPACE uISHEET,1 , 3/10" TAPCON SACKER ROD—� 3/16" TAPCON & APPROVED ! SEALANT I i � i INTERIOR.. � f � t DOLS INTERIOR EXTERIOR I j 1IF I MIN. ; 1 ! EDGE I � DISTANCE a�J EXTERIOR Hi ! BACKER ROD—/ SACKER ROD f I ! & APPROVED o"c APPROVED I SEALANT JAMB INSTALLATION DETAIL SEALANT i` l i 'r; CONCRETFIMASONRYINSTALLATION _ _ D SILL TO BE S IN A BED OF APPROVED SEALANT 114" MAX. NOTES: OPTIONAL 1X BUCK I r SHIM SPACE 1.1NTERIORANDSGERIORFINISHES.BYOTHERS, SEE NOTE NOTSHOWNFORCLARRY. SHEET 1 Q 2.PERIMETERAND JOINTSEALANTBY OTHERS TO BE DESIGNED 1N ACCORDANCE WITH ASTM E2112 —�� SIGNED:06/24/2075 I•. w e e •a u e T Ow f/3TERNNKwECfufuLSISTEMt �;{II11! 1 Eastern s° . s :t""vw":=-li.v000—.� FO�AfWE�S RAowa z> ] ..�`�£Ns 9s�ii SERIES 176 SH VINYL SINGLE HUNG WINDOW \ IMPACT 54." X 77" — — \ INSTALLATION DETAILS p: OTA7' OF CONCRETE/}AASONRY D;KWN: am0NOS SECTION . 'cC.ORidP•.���� ' CONRCRETEIMASOTICAL ORYINSTALLATION BY OTHERS N.G. NTS D"TE 11/17/14 08-025385260E 7 A /''�ssV�NA11��G\\\\ . r" g . REV60N5 1 1/4"'MIN. REL' EMBEDMENTOES: W-h RIPTION. NPROVM SEdLAN7 � ' , BEHMD FIN \ WOOD A RE nSED WSTALLATIN DETARS 06/23]t5. R.L, FRAMING` #10.W000 BY OTHERS SCREW 1 144 MAX. 1:/2" MIN SHIM SPACE EDGE DISTANCE W006 FMING —1 1/4 MAX RA BY OTHERS� I �SHIM SPACE INTERIOR Y 1 1/4- L OO I MIN. l ! rl]. _ EXTERIOR I L INTERIOR EMBEDMENT I j #10 WOOD SCREW j APPROVED -� 1:'2 MIN EXTERIOR SL4>ANT -DGE DISTANCE BEHIND FIN I JAMB INSTALLATION DETAIL WOOD FRAMING OR2XBUCKINSTALLATION 0 1/4- MAX_ NOTES: 1�!J 5'r.11f: SPACE T.INTERIOR AND EXTERIOR FINISHES.BYOTHERS. i j NOT SHOWN FOR CLARITY. 2.PERIMETER ANDJOWT SEALANT BY OTHERS TO BE I/2" tJIN �, DESIGNED INACCORDANCE WITHASTMM12 EDGE DISTANCE10 WOOD 'NOOD SIGNED:06/24/2015 �11111(f.! SCREW FRAMING Eastern �o ,a \\��� g L p��/� 1 1/4" MIN. BY OTHERS �sremN[rKsevLr \�\\s APPROVED E1dBEDMf ^r -._a. waive° ftooama �r•�\G.ENa SEALANT ,`'. °°°�'° F'- _ BEHIND FIN VERTICAL CROSS SECTION SERIES 176 SH VINYL SINGLE HUNG WINDOW �*' o��L'S WOOD FRAMING OR 2X SUCK INSTALLATION IMPACT 54" X 77" (7C� INSTALLATION DETAILS ; STATE OF DRAWN: OPIK,':A. FEV jFd;..c�OR10P 16. iG1E oau o8—S02538 A SYONAj1E�\\\� NTS 11/17/14 -!:E7 OF 7 i Florida Building Code Online Page 1 of 6 o o- ' va r Flolida Department! BCIS Home Log In I User Registration Hot Topics Submit Surcharge Stats&Facts Publications FK Staff I SCIS Site Map I Links I Search Busines. PruAp Professi nal 4USEoR:d Pubicc UrserOVdI Regulation Product ADDroval Menu>Product or Application Search>Application List>Application Detail FL# FL12334-R6 Application Type Revision Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived ❑ Product Manufacturer Therma-Tru Corporation Address/Phone/Email 118 Industrial Drive Edgerton,01-143517 (419)298-1740 rickw@rwbldgconsultants.com Authorized Signature Vivian Wright rickw@rwbidgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By Ryan J. King,P.E. W Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year ASTM D1929 1996 ASTM D2843 1999 ASTM D635 2003 ASTM D638 1996 ASTM E1300 2004 ASTM E84 2000 ASTM G26 1995 TAS 201,202,203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL12334 R6 Eguiv of Standards.odf http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtF2AeAma 9K... - • f , v.ivlrua Uuliuutg 4.vuu viume, rage l of 0 Product Approval Method Method 1 Option A Date Submitted 03/10/2016 Date-Vaildated 03('14(2016 Date Pending FBC Approval Date Approved 03/13/2016 Date Revised 10/13/2016 SuMMary of Products FL# Madel,Number or Name Description 12334.1 a."ClassicCraft","CiassicCraft 'Impact"8'0'Glazed Fiberglass Single Door utilizing Hoppe Rustic",'FiberClassie or Multi Point lock-Outswing configuration(X) 'SmoothStar"Series Urnits of use Certification Agency ertil ieate Approved for use in HVHZ:Yes FL12334 R6 C CAC 12334.1 NAMI CERT.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 03/31/2026 Design Pressure:N/A Installation Instructions other-.,See INST 12334.1-for Design Pressure Ratings,any FL12334 R6 II INST 12334.1.adf additional use limitations,installation instructions and Verified By:Lyndon F.Schmidt,P.E.43409 product particulars.(Note-ASTM E1300-04 utilized for Created by Independent Third Party:Yes areas inside the HVHZ) Evaluation Reports FL12334 R6 AE EVAL 12334.1, FL12334 R6 AE TT-PLASTICS,1.odf Created by Independent Third Party:Yes 12334.2 b.'ClassicCraff,"ClassicCraft "Impact"8'0 Glazed Fiberglass Single Door with Sidellte Rustic',"FiberCiassic"or utilizing Hoppe Multi Point lock-.Outswing configuration(OX "SmoothStar'Series or XO) Units of Use Certification Agency Certificate Approved for use in HVHZ;Yes FL12334 R6 C CAC 12334.2 NAMI CERT.odf Approved for me outside tlVJM Yes . Quality Assurance Soldract ExpirWOR Date Impact Resistant:Yes 03/3112026 Design Pressure:N/A Installation Instructions Other.See INST 12334.2 for Design Pressure Ratings,any FL12334 R6 II INST 12334.2.odf additional use limitations,Installation instructions and Verified By: Lyndon F.Schmidt P.E.43409 product particulars.(Note-ASPM E130044 utilized for Created by Independent Third Party:Yes areas inside the HVHZ) Evaluation Reports FL12334 R6 AE EVAL 12334 2.odf FL12334 R6 AE TT-PLASTICS,1.Qdf Created by Independent Third Party.Yes 12334.3 c.'ClassicCraft",'ClassicCraft "Impact"8'0 Glazed Fiberglass Single Door with Sidelites Rustic","FiberClassle or utilizing Hoppe Multi Point lock-Outswing configuration 'SmoothStar'Series '(OXO) 13mits of use Certification Agency Cer#W=a to Approved for use in HVHZ:Yes FL12334 R6 C CAC 12334.3 NAMI CERT.odf Approved for use outside HVHZ:Yes Quality Assurance Cmatract Expiration Data Impact Resistant:Yes 03/31/2026 Design Pressure:N/A Installation Instructions Other.See INST 12334.3 for Design Pressure Ratings,any FL12334 R6 II INST 12334.3.odf additional use limitations,installation instructions and Verified By:Lyndon F.Schmidt,P.E.43409 product particulars.(Note-ASTM E1300-04 utilized for Created by Independent Third-Party:Yes areas inside the HVHZ) Evaluation Reports FL12334 R6 AE EVAL 12334.3.odf FL12334 Rfj AE TT-PLASTICS 1 od€ Created by Independent Third Party:Yes 1.2334.4 jd.'ClassloCraft°,"ClassicCraft "Impact"8'0'Glazed Fberglass'Dauble Door utilizing Hoppe Rustic',"FiberClassie or Multi Point loch-Outswing configuration(XX) "SmoothStar"Series urnits of use Certification Agency Certificate Approved for use in HVHZ:Yes FL12334 R6 C CAC 12334A NAMI CERT odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration-Date Impact Resistant:Yes 03/31/2026 Design Pressure;N/A Installation Instructions Other:See INST 12334.4 for Design Pressure Ratings,any FL12334 R6 II INST 12334 4 odf additional use limitations,installation Instructions and Verified By:Lyndon F.Schmidt,P.E.43409 product particulars.(Note-ASTM E1300-04 utilized for Created by Independent Third Party:Yes areas inside the HVHZ) Evaluation Reports FL12334 R6 AE E_VAL 12334.4.1)d FL12334 R6 AE TT-PLASTICS 1 odf Created by Independent Third Party:Yes drip.//www.floridabuilding.org/pr/pr app_ tl.aspx`PaMM=WGEVXQwtDgtF2Aezuarjg3K.,,, 7/26/2017 rv>.Lua iju11u111g t-oue unime Page 3 of 6 12334.5 e.'ClassicCraft","ClassicCraft "Impact'8'0 Glazed Fiberglass Double moor with S•sdelites Rustic","FiberClassie or utilizing Hoppe Multi Point lock-Outswing configuration "SmoothStar"Series (OXXO) Limits of Use Certification Agency Cestiftate Approved for use in HVHZ:Yes FL12334 R6 C CAC 12334.5 NAMI CERT_pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Reststimu Yes 03/31/2026 Design Pressure:N/A Instunation instructions Other:See INST 12334.5 for Design Pressure Ratings,any FL12334 R6 II INST 12334 5 odf additional use limitations,installation instructions and Verified By:Lyndon F.Schmidt,P.E.43409 product particulars.(Note-ASTM E1300-04 utilized for, Created by Independent Third Party:Yes areas inside the HVHZ) Evaluation Reports FL12334 R6 AE EVAL 12334 5 pdF FL12334 R6 AE TT-PLASTICS 1 pdf Created by Independent Third Party:Yes 12334.6 f."Classiccraft","Classiccraft "Impact"8'0"Glazed Fiberglass Single Door-Outswing Rustic",'FiberClasste or contiguralion(X) "SmoothStar'Series Limits of Use Certification Agency-Certificate Approved for use in HVHZ:Yes FL12334 R6 C CAC 12334,6 NAMI CERT odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 03/31/2026 Design Pressure:N/A Installation Instructions Other:See INST 12334:6 for Design Pressure Ratings,any FL12334 R6 II INST 12334 6 odf additional use limitations,installation instructions and Verified By:Lyndon F.Schmidt,P.E.43409 pro¢uot parMPlars.(Note-ASTM El 300-04 utilized for Created by Independent Third Party:Yes areas inside the HVHZ) Evaluation Reports FL12334 R6 AE EVAL 12334 6 pdf FL12334 R6 AF�TT-PLASTICS i pdf Created by Independent Third Party:Yes 12334.7 g."ClassicCraft","ClassicCraft "Impact'8'0 Glazed Fiberglass Single Door with Sidelite- Rustic","FlberCJasslc".or Outswing configuration(OX or XO) 'SmoothStar'Series Limits of Use Certification Agency Cettilkate Approved for use in HVHZ:Yes, FI-12334 R6 C CAC 12334.7 NAMI CERT pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 03/31/2026 Design Pressure:NIA installation Instructions Other:See INST 12334.7 for Design Pressure Ratings,any FL12334 R6 II INST 12334 7 odf additional use limitations,installation instructions and Verified By:Lyndon F.Schmidt,P.E.43409 product particulars.,(Note-ASTM E1300-04 utilized for Created.by Independent Third Party:Yes areas inside the HVHZ) Evaluation Reports LI 334 R6 AE EVAL 12334.7.i)df FL12334 R6 AE TT-PLASTICS 1 pdf Created by Independent Third Party:Yes 12334.8 h."ClassicCraft","ClassicCraft 'Impact"$'0 Glazed Fiberglass Single Door with Sidelites- Rustie,'FiberClassic"or Outswing configuration(OXO) 'SmoothStar"Series Limits of Use Cartiflication Agency Certifscate Approved for use In HVHZ:Yes FL12334 R6 C CA_C 12334.8 NAMI CERT pdf Approved-for useoutside HVHZ:Yes Quality Assurance.Contract_Expiration Isatin Impact Resistant:Yes 03/31/2026 Design Pressure:N/A Installation Instructions Other:See INST 12334.8 for Design Pressure Ratings,any FL12334 R6 II INST 12334 8 pdf additional use limitations,installation instructions and Verified By:Lyndon F.Schmidt,P.E.43409 product particulars.(Note-ASTM E1300-04 utilized for Created by Independent Third Party Yes ureas inside the HVHZ) Evaluation Reports FL12334 R6 AE EVAN.12334$pdf FL12334 R6 AE TT-PLASTICS Lod Created by Independent Third Party:Yes 12334.9i."ClassicCraft","ClassicCraft 'Impact"8'0"Glazed Fiberglass Double Door-Outswing Rustic","FiberCiassic'or configuration(XX) 'SmoothStar"Series Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL12334 R6 C CAC 12334.9 NAMI CERT.pd Approved for-use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 03/31/2026 Design Pressure:N/A Inptal[W-9n Instructitrns Other.See INST 12334.9 for Design Pressrum Ratings,any FL12334 R6 II INST 12334 9 odf additional use limitations,installation instructions and Verified By:Lyndon F.Schmidt,P.E.43409 product particulars.(Note-ASTM E1300-04 utilized for Created by IndependentThird Party:'Yes areas inside the HVHZ) Evaluation Reports FL12334 R6 AE EVAL 12334 odf FL12334 R6 AE TT-PLASTICS 1 odf Created by Independent Third Party:Yes hnp,//www floridabuilding.org/pr/pr_app sitl,aSPX?Pagano=WGEVXQwtDgtF2Aezua�g&,, 7/26/2017 Page 4 of 6 12334.10 j.'ClassicCrafr,"ClassicCraft -Impact-WO Glazed Fiberglass Double Door with Sidelites- RusUe,'FiberClassie or Outswing configuration(OXXO) "SmoothStar"Series Limits of Use Certification Agency Certificate Approved for use in HVHZ.Yes FL12334 R6 C CAC JXZL34.10 NAMI CERT,od Approved for use outside HVHZ:,yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 03/31/2026 Design Pressure:.N/A Installation Instructions Other:See INST 12334.10 for Design Pressure Ratings, FL12334 R6 11 INST 12334.10.pd any additional use limitations,installation insto-uctions and Verified By,Lyndon F.Schmidt,P.E.43409 product particulars.(Note-ASTM E1300-04 utilized for Created by,Independent Third Party:Yes areas inside the HVHZ) Evaluation Reports FL12334 R6 AE EVAL 12334.10.0 FL12334 R6 AE E_-PLASTICS.I.Dolf CM-ated by independent Third P,3rtr.Yes 12334.11 k.-ClassicCrafV,-ClassicCraft 'Impact'810"Glazed Fiberglass Single Door utilizing Hoppe Rustie,'FiberCiassie or Multi Point lock-Inswing configuration(X) Limits of Use 'SmoothStarl Series Certification Agency Certificate Approved for use in HVHZ-.Yes FL12334 R6 C CAC 12334.11 NAMI CERT.I)d Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant-Yes 03/31/2026 Design Pressure:N/A Installation Instructions Other.See INST 17334.11 for Design Pressure Ratings, FL 2334 R§ Il INST 12334.11,nd any.addilignof use limitations,in0talloflon instru do - -cliorts and Vgrifted By. Lyndon F.$chmiflt,P.E.43409 product particulars.(Note-ASTM E1300-04 utilized for Created by Independent Third Party.Yes areas inside the HVHZ) Evaluation Reports FL12334 RG AE EVAL 12334.11.pdf FL12334 R6 AE TT-PLASTICS 1.pdf Created by Independent Third Party:Yes 12334-12 1.1.-ClassicCraft-,'ClasslaCtaft "Impact"8'0 Glazed Fiberglass Single.Door with Sidelite Rustic",'FiberClassic"or utilizing Hoppe Multi Point lock-Inswing configuration(OX 'SmoothStar'Series or XO) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL12334 R6 C CAC 12334.12 NAMI CERT,I)d Approved for use outside HVHZ-.Yes Quality Assurance Contract Expiration Date Impact Resistant-Yes 03/31/2026 Design Pressure:N/A Installation instructions Other See INST 12334.12 for Design Pressure Ratings, FI12334R6 11 INST 12334.12.pdf any additional use limitations,installation Instructions and Verified By:Lyndon F.Schmidt,,P.E.43409 product particulars.(Note-ASTM E1300-04 utilized for Created by Independent Third Party:Yes areas inside the HVHZ) Evaluation Reports FL12334 R6 AE EVAL 12334.12.pdf FL12334 R6 AE TT-PLASTICS 1.p df Created by Independent Third Party.Yes 12334.13 in."ClassicCrafV,"ClassicCraft "Impact"WO Glazed Fiberglass Single Door with Sideiltes Rustic',"FiberClassic"or utilizing Hoppe Multi Point lock-Inswing configuration "SmoothSta r"Series (6x0) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL12334 R6 CAC 12334,13 NAMI CERT.pd Approved for use outside I"Z-Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 03/31/2026 Design Pressure:N/A Installation Instructions Other.See INST 12334.13 for Design Pressure Ratings, FL12334 R6 11 INST 12334.13.pdf any additional use limitations,installation instructions and Verified By:Lyndon F.Schmidt,P.E.43409 product particulars.(Note-ASTM E1300-04 utilized for Created by Independent Third Party:Yes areas inside the HVHZ) Evaluation Reports FL12334 R6 AE EVAL 12334,13.f)df FL12334 R6 AE TT-PLASTICS.1.0f Created by Independent Third Party.Yes 12334.14 n."ClassicCraft,'ClassicCraft 'Impact"&0"Glazed Fiberglass Double Door utilizing-Hoppe Rustic',"FiberClassic'or Multi Point lock-Inswing configuration(XX) "SmooffiStar"Series Limits of Use Certification Agency Certificate Approved for use in HVHZ-Yes FL12334 R6 C CAC 12334.14 NAMI CERT.pd -Approved for use outside t#VHV—^Yes Quality Assurance Contract Expiration Date Impact Resistant.Yes 013112()26 Design Pressure-N/A installation instructions Other:See INST 12334.14 for Design Pressure Ratings, FL12334 R6 11 INST 12334.14.gdf any additional use limitations,installation Instructions and Verified By:'Lyndon F.Schmidt,P.E.43409 product particulars.(Note-ASTM E1300-04 utilized for Created by Independent Third Party;Yes areas Inside the RVHZ) Evaluation Reports FL12334 R6 AE EVAL 12334.14.0f http://www,floridabuilding.org/pr/pr_app_dtl,aspx?par,am-7wGEVXQwtDqtF2AozuadgK.. 7126/2017 i av�iurt yttilUlu�%,uuc urnine Page 5 of 6 FL12334 R6 AE TT-PLASTICS.i.pdf Created by Independent Third Party:Yes 12334.15 o.'ClassicCraft','ClassicCraft "Impact'8'0 Glazed Fiberglass Double Door with Sideiites Rustic",'Fiberaassic"or utilizing Hoppe Multi Point lock-InsMog configuration "Smooth5tail Series (OXXO) limits of Use Certification Agency Certif a to Approved for use In HVHZ:Yes FL12334 R6.C. CAC 12334 SS NAMI CERT pd€ Approved for use outside HVHZ:Yes Quality Assurance contract Expiration Date Impact Resastarb Yes 3/3112026 Design Pressure:N/A Instaliafion Instructions Other.See INST 12334.15 for Design Pressure Ratings, FL12334 R6 II INST 12334.15_gdf any additional use limitations,installation Instructions and Verified By:Lyndon F.Schmidt,P.E.43409 product particulars.({Yate-ASTM E1300-04 utilized for Created by Independent Third Party:Yes areas Inside the HVHZ) Evaluation Reports FL12334 R6 AE EVAL 12334.15.odf FL12334 R6 AE TT-PLASTICS.1.gdf Created by independent Third Party:Yes 12334.16 p.'CiassicCraft","ClassicCraft 'Impact"8'0'Glazed Fiberglass Single Door-Inswing Rustic",'FiberClassic'or configuration(X) "SmoothStar"Series Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL12334 R6 C CAC 12334.16 NAMI CERT,pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 03/31/2026 Design pressure:N/A tnstallation Instructions Other.See INST 12334.16 for Design Pressure Ratings, FL12334 R6 II INST 12334 16 pdf any additional use limitations,installation instructions and Verified By: Lyndon F.Schmidt,P.E.43409 product particulars.(Nate-ASTM E1300-04 utilized for Created by Independent Third Party:Yes areas inside the HVHZ) Evaluation Reports FL12334 R6 AE EVAL12334.16.pdf FL12334 R6 AE TT-PLASTICS.1 pdf .Created by IndependentThlyd.Party:Yes 12334.17 Q.'classiccraft","Classil:craft "impact"8'0 Glazed Fiberglass Si.ngie Door with.Sidelite- Rustic,'FiberClassic'or Inswing configuration(OX or XO) "SmoothStar'Series Limits of Use Certification Agency.Certificate Approved1br use in HVHZ:Yes FL12334 R6 C CAC 12334 17 NAMI CERT.pd Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact ReSistarri;Yes 03/31/2026 Design Pressure;N/A -Installation Instructions Other:See INST 12334.17 for Design Pressure Ratings, FL12334 R6 I1 INST 12334 17 odf any additional use limitations,installation instructions and Verified By.Lyndon i.Schmidt,.P-E.43409 product particulars.(Note-ASTM E1300-04 utilized for Created by Independent Third Party:Yes areas inside the HVHZ) Evaluation Reports FL12334 R6 AE EVAL 12334.17.t�df FL12334 R6 AE TT-PLASTICS.1.g_df Created by Independent Third Party:Yes 12334.1Er."-ClassicCraft",'CtassicCraft 'Impact"8'0 Glazed•Fiberglass Single Door with Sidelites- Rustie,"FiberCiassic'or Inswing configuration(OXO) "SmoothStar'Series Limits of Use Certification Agency certilikate Approved fnruse 1.MVHZ:Yes FL12334 R6 C CAC 12334 18 NAMI CERT.pdf td Approved for use outside HVHZ:Yes Quality Assurance Contract Exp-nation Date Impact Resistant:Yes 03/31/2026 i Design Pres sure:N/A Installation Instructions Other.See INST 12334.18 for Design Pressure Ratings; FL12334 R6 i1 INST 12334.18,pdf 0 any additional use limitations,installation instructions and Verified By:Lyndon F.Schmidt,P.E.43409 product particulars.(Note-'ASTM E1300-04 utilized for Created by Independent Third Party:Yes areas inside the HVHZ) Evaluation Reports FL12334 R6 AE E/tAL 12334 18 pdf FL12334 R6 AE TT-PLASTICS.I.pdf Created by Independent Third Party:-Yes 12334.19 s.'"ClasslcCraft%"ClassicCsaft "Impact"8'0"Glazed Fiberglass Double Door-Inswing Rustic,"FiberCiassic or configuration((X) '5mmthStar"series Limits of Use Certi kation Agency Certi cote Approved for use in HVNZ;.Yes FL12334 R6 C CAC 12334.19 NAMI CERT.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 03/31/2026 Design Pressure:N/A Installation Instructions Other.See INST 12334.19 for Design Pressure Ratings, FLi2334 R6 II INST 12334 19 pdf any additional use limitations,installation instructions and Verified By:Lyndon F.Schmidt,P.E.43409 Created by Independent Third Party:Yes http://www floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtF2Aezu,-ujglC.. 7/26/201.7 uunaing Code Online Page 6 of 6 P;: particulars.(Note-ASTM E1300-04 u7:]C—ated forEraheatiara Reports areas inside the HVHZ) FL12334 R6 AE EVAL 12a34 i9 pdf FL123344 R6 AE_7T-PLASTICS i odr by Independent Third Party:Yes 17334.20 t."ClassicCraft","ClasstcCraft "Impact"S'0 Glazed Fiberglass Double Door with Sidefites- Rustle, FiberClassic".or Inswing configuration(OXXO) "SmoothStar"Series Limits of Use Certification A Certiff Approved for use in HVHZ:Yes R ' FL12334 R6 C CAC 12334,20 NAMI CERT odf A pact R for irse aulside HVHY Yes Quality Assurance Contct.E raxpiration Date Impact Resistant:Yes 03/31/2026 Design pressure:N/A Installation Instructions Other:See INST 12334.20 for Design Pressure Ratings, EL12334 R6 II INST 12334 20 Ddf any additional use limitations,installation instructions and Verified By:Lyndon F.Schmidt,P.E.43409 -product particulars.(Note-ASTM€1300-04 utilized for Created by Independent Third Party:Yes areas inside the HVHZ) Evaluation Reports FL12334 R6 AE EVAL 12334.20.1)df FL12334 R6 AE TT-PLASTICS 1 Ddf Created by Independent Third Party:Yes back I Next Canta4#yg::2601 Blair Stone Road Tallahassee FL 32399 Phone:850-4§7-1824 The State of Florida is an WEED employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility tatement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please dick bar . Product Appmval AcMts: a5Q, WN Ka 0 Credit Card Safe 'Q�'DW-' lAe,z�a j��,,, "I12612Q17 .. 1i THERMAITRU THERMA TRU DOORS 1 1 B INDUSTRIAL DR., EDGERTON. OH 4351 7 ° SMOOTH STAR FIBER CLASSIC - 116.75 ru,X.OAFTL4ME �.,,,;11 ;t%,•��° o �z W/2X MULL.REINF. ' ' a xz CLASSIC CRAFT & CLASSIC CRAFT RUSTIC 37°50 MAX37.75*MAX E E� m FRAME WIDTH�j FRAME WIDTH—� Q� Y 9 d t a ! - a 01 0 (L r FIBERGLASS GLAZED DOOR WITH SIDELITES PANEL WZ INSWING _ N: `IMPACT` Ca w O W2 GENERAL NOTES / itg o_x �U T. This product anchoring drawing has been developed in compliance with the 5th Edition(2014)Florida Building Code(FBC)including the"High Velocity Hurricane Zone(HVHZ).See the Certification Agency rs a y ori Certificate forsrzes,specifications and ratings. t7 = xs H _ L 2. Product anchors shall be as fisted and spaced as shown on details.Anchor embedment to base materiel shall be beyond wall dressing or stucco. < ° 3. When used in fhe HVHr this product complies with Section 1626 of the FBC and does not require an S ° impact resalonlcovering. C O x O 4 m 4. When used In areas outside of the"HVHr requiring wind borne debris protection this product cornpries withe Section 1609.12 of the FBC and does not r equve an impact resistant covering.This product meets missile level"V and includes Wind Zone 4 as defined in ASTM E 1996 and Section 1609.1.2.2 of the FBC. 0 j ` x •� 5. For 2z stud framing corstnrction,anchoring of these units shall be the some as that shown for 2x buck � %�' �;%' /:• d�� z o` masonry construction. N_ 6. Site conditions that deviate from the details of this drowing require further engineering analysis by a Gcersed engineer or registered architect. o o 2 U 0 7. Inswing configurations using sill item 1133 do not meet the water infiltration requirements for the'HVHT and 1.5 REINFORCEMENT ¢•w�y a shag be installed only in non-habitoble areas or of habitable locations protected by an overhang or 0- canopy such that the angle between the edge of canopy or overhang to sill is less than 45 degrees. TABLE OF CONTENTS o m a a a z SHEET DESCRIPTION SHEET DESCRIPITON z 1 Typical elevations,design pressures&general notes 8 Vertical cross sections I n a z o° Z 2 Door panel details$glazing details(Smooth Stor) 9 Vertical cross sections ah, 3�r 7 09 a 3 Door panel details(Fiber Classic] 10 Buck anchoring OWEIZALLw DESfGN PQESSUREPSQ; o 4 Door panel details Classic Croft N.I.S. P l 1 11 Frame anchoring 2X buck masonry construction Sfq//NC FRAME 5 Doer panel details(Classic Croft Rustics 12 Frame anchoring IX buck masonry construction : _ 1)I ttENSf01( PC}S1TNE NEGi47TV�i;: o 8 0 JK m 6 Siderite panel details 13 Big of maferiols 000 BY. LF 3 7 Horizontal cross sections INSWING 115.75"x97.17" +50.0 -55.0 °A�NNG"O.0 5 FL–f 2334.113 v 0 u s+r:Er OF 13 R'\Clients\Therms Tru PERMANENTVWdda Product Approvals\FL-12334\Drawings\Cutrent\FL•12334.16.20.d",C-2 a Q Q 0 0 g a a O . 0 Om D O � �-1.54" rn Q m w m p ro � i O 0 2 N --- O f N N D D �4 zm a 1) A yam. p N b N N Ui AI T O OD r _ PC N m No.43409•' PRODUCT: Dooumanb Prepared Byn'.- UVU OF THERA{A TRU Lyndon P. Sohm(dt i� 3 2 OS 15 UPDATE TO $TtJ ED. 2014 F8C US RGERGLASS GLAZED DOOR P.E. No. 43409 *"'M/�lAt.\\ W r^ -i 4 2 3 6 12 REVISE TO CERT. MARK METHOD LFS PART OR ASSEMBLY: CD��f/ BUIIhINO CONSULTMIiS,�NC. r l !' '*r �' ir1�" 7 3/9/11 REWSE CLASSIC CRAFT DOOR JK YY A.O. Box 230, Vatrioo, FL 33595 u to NO DATE BY DOOR PANEL DETAILS & GLAZING phone No.: 813,659.9197 REVISIONS DETAILS (SMOOTH STAR) FBPE CA No. 9813 02009 R.W.BUILDING CONaOLTANTa INC. IL aenls\Thenm Tim PERWMENTVtorida Product Appmvatt\FL,12334\DtaMngs\Cuttent\FL-1233416-20.dwg,C-3 79.43"MAX,D.L.O. 0 0 0 ua 0) G\,1 0,911, 'a M M 0 0 lot: all I AS' (A C- I� M ;0 Vt ESQ 's 0 M No,43409 .)rz PRODUCT: Doan -t.pmcomd THERMA-TRU Lyndon F. Schmidt • .......... FIBERGLASS GLAZED DOOR P.E. No. 43400 jw —3 M21.5 UPDATE TO 5'H'ED, (2014 FDC -L-Ffl - a "I'm Ii%%%% WSF TO CERT. MARK METHOD CONSULTANTS' 0. 2 JFS PART OR ASSEMBLY: REVISE CLASSIC CRAFT JK spu.nIN.C.- -'30 Voldco, FL 33505- MOR BY DO?f PANCELLASOSET NO__gATE I IBER ICILS Ph.,. No.: 81.3,659.9197 b _1 REVISIONS I FSPE C.A. No. 98t3 0 2009 R.W.BUILDING CONDULTAWS INC. R�Qients\Therrm Tru PERMANENT\Flodda Ptoduct Approvals\FL-12334\Drawings\Current\FL-12334.16-20.dwg,C-4 ....... 79.0 D.L.O. P 9-2 o > 0 0 M;. 0 0 3- W 0 0 0 0 0 OO 1 0 0 L000- = 0 0 01, 0 cc 0 /ZN 0.91" Mr 01. C; 1.49" 0.81" I70 A I I PO m -0 W 140.43409 I PRODUCT.. tWcumenb PftpuMd or. midt THERMA-TRU V�ndon F. Soho I FIBERGLASS GLAZED DOOR No. 434C —3 UPDATE TO 5THED. LFS I " (2O 14) FDC BUILDING C. 2 REVISE TO CERT. MARK METHOD LFS PART OR ASSEMBLY- OTR NELCRDAEMTAILS P.O. Do. 230, Wrico, FL 33595 I M-3 REVISE CLASSIC CRAFT DOOR JK I CLAA -go— DATE BY SIG Ph-A6 No.; 813.659.0197 REVISIONS FaPE C.A. No. 9813 02009 R.W.a......a Ca.8—T.—.1".. RACllents\Therma Tru PERMANENT\Flodda ProductApprovalsVL•14334\Drawings\Current\PL-12334.16.20Ahs C•5 79.63"MAX.D.L.O, 0 A I 1 0 0 c" s' o (> w 3 a' O o ED G, O 0 �O O N - Am o �m� s Z H A (JI 700 t11 s i } �s L.n �u sk}'r r�nt3,yt's•Y�,44 L}i iL:r''tt y't cl in�,sS —' A v rt£y` r. Asst�� �eYs�Y�.,-'•��il iv h � /csy -s +� n`j }s:':ra1:'.i t:•,.�•.i'ys tt*:. s` '..Y.Ii::�h j�' ^S•"r.L,^. _L � A 7.9a"—• M w f I.4Y H W i'�z 5"iti n n < ; P O 1�,.. m A .'O N ` •• No.43408 *_ * 3I Zs/3- " 0 Q PRODUCT: Daoumanta Pnp—d OF. •. THERMA-TRU Lyndon F. Schmldt i '• �o1ac�1•'' IN w z 3 2 06 15 UPDATE TO 5TH ED. 2074 F8C LF3 FIBERGLASS GLAZED DOOR P.E. No. 43409 /// s+��...... R W y v 2 3 6 12 REVISE TO CERT. MARK METHOD LFS PART OR ASSEMBLY: GD�/�� BUILDING CONSULTANTS, . Iw po z m NO DATE REVISE CLASSIC CRAFT DOOR eK DOOR PANEL DETAILS tJ�tY phone No23813.6 9.0. 91 7 J3895 REVISIONSI (CLASSIC CRAFT RUSTIC) FBPE CA No. 9813 0 2009 H.W.DUILOINo CONOULTANTe IND, RNCllenU\Thermo Tru PERMANENT\Florida Product Approvats\FL•12334\Drawings\Current\FL•12334.16.20.dwg,C-6 79.63"MAX,D.L.O. ro r. . Q O� o _ r— m D •�� A r O m 0 O 0 � a 0 0 Z6 a 0 0 A O p•�. � 0 A z N b " A 0,66•' D 70 OIA O A c.1 N ' O Z ••Tr' •WO 0.66' 00 O•N OD N W A M T1 A AI y m Z a Cu w N o• N � A \`\tLlLllllll!/�f/ A ITr No.43409 b PRODUCT: Doeum.nh Pnp—d THERMA TRU Lyndon F. Sehmldtf2gp0/,.•' FIBERGLASS GLAZED DOOR P.E. No. 43409 �i,t43j'••• `��`� °I N o 2 3 2 06 15 UPDATE TO 5TH ED. 2014 FBC LFS !l///j�1/4�11\\1 3 6 12 REVISE 70 CERT. MARK METHOD LFS PART OR ASSEMBLY: G���! BUILDING CO NSULTANTS�I��C. IL' pe N 1p NO DATE11 REVISE CLASSIC CRAFT DOOR BY SIDELITE PANEL DETAILS YY P.O. Boy 230, Volrico, FL 33595 Phone No.: 813.839.9197 REVISIONS FBPE C.A. No. 9813 2009 R.W.Bt11L01NO CONBULTANTB INO. k\Clients\Therms Tru PERMANENT\Florida Product Approvals\FL•12334\Drawings\CunentVL-12334.16.2o.dwg,C-7 •°a C Ft ° t ° 41 0 0 �g 0 03 z Vf :` m z3 _� tnN O Z A O •o w •" 0 O rn b N n y> � Z> �Z V N j L V A O � nt a— lH !7S N 181 A _ ami G a� Ila z; o n z w �+ 0 0 o 0 O p V O• O O Hy n Zloe V W O V .p O O O Eri Z• f 0 n \ � X H - c A m d _ 7n0 `� y •.. ra < .v 1 .V z Ooo O 2 m \1011111114 No.43409 S PRODUCT: Dxvmant.Pr"—d_Vrn QOITE or f• iHERMA TRU Lyndon F. Schmidt ��i� +�g50f�•,.•' L4 FIBERGLASS GLAZED DOOR P.E. No. 43409 •�" I`r W Z 3 2 06 15 UPDATE TO 5TH ED. 2014 FBC LFS $ a < 2 3 6 12 REVISE i0 CERT. MARK METHOD LFS PART OR ASSEMBLY: LD��/ BUILDING CONSULTANT y 1; p 1 3 9 f i REVISE CLASSIC CRAFT DOOR JK YY P.O. Box 230. Vafrlco. FL 33595. _ IC, m NO DATE By HORIZONTAL Phone No.: 813.659.9197 REVISIONS CROSS SECTIONSFBPE C.A. No. 9813 0 2009 R.W.BUIr.Dlna GoneULTANTS No. 0.NCllents%Therma Tru PERMANENTV106da Product Approvals\FL•12334\Drawings\Curmnt\FL•12334.1830.dwg.C•8 v ^' O � o 0 a b r - •'o. O Cc v m � m Z 0 C`SINK- a (TYP.) T'1J4"MLN. EMB.(ttP.) t 8 EMB.(TYP.j o o M v v .Oro n � m goer i:: g; M xO o o �- ° ro A o C � to m n Z .Oro - m V n ° 0 1.1/4"MIN. EMB.(TYP.) �tttlllli!!tt No.43409 Y .._. PRODUCT: Do-to Pmpor.d Or. 6TAYC OF •• ,� r'1 ` THERMA TRU Lyndon F. Schmidt 'i, `'•F2tJfG6R�' �Q I t FIBERGLASS GLAZED DOOR P.E. No. 43406 Ioc A S Z 3 2 06 15 UPDATE TO 5TH ED, 2014 FBC LFS IL11IIi1tt 2 3 6 12 REVISE TO CERT. MARK METHOD VS PARI OR ASSEMBLY: GDnl/ BUILDING CONSULTANTS, INC. tix to p 1 3 6 1 t REVISE CLASSIC CRAFT DOOR JK VERTICAL YY P.o. Boz 230, Vatrlco, FL 33595 po `O NO DATE BY CROSS SECTIONS Phone No.: 613.656.0107 REVISIONS FBPE C.A. No. 9813 0 2009 R.W.BUILOINO CONSULTANTS INC. G FLACIlents\Therma Tru PERMANENT\Fiorida Product Approvals\FL-12334\Drawings\Cunent\FL-12334.16.20.dwg.C-9 � m A22 pppp to O 2 < Go 4 tTt • Lmf1 � •a N to •. T �• Z p• 4 M A 1.I/4"MIN. C'SINK EMB.(TYP.( (TYP.( N 0 m A < v r M ' t EMB. EMB.(TYP.) O n �' 5`r• on N :A.�.. '•d' r�+i� A _ 76 Go "�T V t 4 I A r^ O D P t m x r— �A 2 !!Z � V Iz p 6A � 3 m ogx .v b c 3 T a au ro 1-1/4"MIN. $ EMB.(TYP.)_.-._ 9 6 \\%% �18CHMff��i' v`-* I.. j' No.43409 ' PRODUCT: Documents PfapOrod 13y:--:, • OL1181 F76ERGLASS GLAZED DOOR Lyndon F. Schmidt i AtO..... ` P.E. No. 43409 �� �••••••••• to N Z 3 2 06 15 UPDATE-TO 5TH ED. 2014 FBC IFS 0 W`' ff1111 1111 a ` 2 3 6 12 REVISE i0 CERT: MARK METHOD LFS PART OR ASSEM13LY: LDqBUILDING CONSULTANTS,�NC. It W N x to NO OATEf 1 REVISE CLASSIC CRAFT DOOR eY VERTICAL VU P.O. Box 230, Volrleo, FL 33595 , CROSS SECTIONS Phone No.: 813.859.9197 REVISIONS FBPE C.A. No. 9813 0 2009 R.W.BUILDINO CONSULTANTS INC. _a_Tru m___aProduct Appr_+12334\Drawi __-123 - C-10 'n §§ § \&j§ m : , 5.__ , _ Kk ; \7R; \Sq ook : . , , , Ee £m o , Z d §{(: a § % � �: x ,-• _ . k P.61 z d : «am0}(§ d� ; &|/an Q:)3 - I kE� §/ 90 I o / §\OR2 \[ bl, ® m & y . ..§. (E2 & ° U A/\ \\\ \ - $&® $ 7 &7 2R ( ® %$I o d$R \® \ � / ER �/ƒ ) m(� k - — - _ _ _ _ _ - . � Oil .� .�.) < No,43409 \� ; . I_wr __.___§ +'r� r +_ e __t � \ G § & , z a a u = s m mi _ FIBERGLASS c z o a « _ MARx� sLFS LART OR ASSEMBLY. .zteems CRkFT DOOR JK � �� � _ek��m/\ \ BUILDING WONSU � o/ W � � « 0S _ec + _, o_9 B___�__. a ' Q M SEE NOTE 2 0 (TYP.) ^O0 3QE`OL;n I 1 1 ( 1 I I 1 1 0 T!*u11 %`` c°i c"'v z L o v Z 0 a M oa a` NY mda� MASONRY TYP.HEAD& 12 JAMBS �r _ OPENING o -4 o= 9 C 41 28 FRAME X a Q _ N° z xz mo pOXQ H NQ R E — o m a� 2X BUCK-\ 12 igo 27 TYP.@ JAMB — TO 1 TYP. REINFORCEMENT SILL 1 1 1 1 ) i —^�6'I— SEE HINGE G SEE NOTE 1 DETAIL o STRIKE JAMB (TYP-) 0 INSWING PRAMEANCHORLNG HINGE JAMB S, N Y E Masonry buck construction d z CONCRETEANCHORNOTES., `" u O 1.Concrete anchor locations at the comers may be adjusted to maintain the min. w > ? edge distance to mortar joints. c U E � 2.Concrete anchor locations noted as MAX.ON CENTER"must be adjusted to 'a a maintain the min.edge distance to mortarjoints.additional concrete anchors ¢t�'„W may be required to ensure the"MAX.ON CENTER"dimension are not exceeded. 28 3.Conaele anchor fable K 9 =0� Ci 10 ANCHOR ANCHOR tG1IM 1NIN CLEARANCE A CL£ARA,NCf� `='— z TYPJ $1ZE JEMBEDM�NX 70 MASONRY TOAOJACENT i o nhO � 2 TAPCON® 1/4" 1-1/4" 2" 4" NOTE l: \ 27 to .�H_z v ELCO 3/16"x 3-1/4"fTw concrete screw toe-nailed 1 atE 3/7 7/G9 z i ULTRACON® 1/4" 1-1/4" 1" 4" through mullion into masonry(each face)at sill �(�� ) Brace: N.T.S. ° F IT{N LATCH d DEAD601TDETAIL HINGE DETAIL U DM er: JK o ® 3/16" 1-1/4" 3" 1-1/2" NOTE 2: TAPCON No.LFS #10 X 3 wood screw toe paled through mullion P WOOD SCREW INSTALLATION NOTES: into masonry(each face)at head I.Maintain a minimum 5/B"edge distance,)"end distance.&1"o.c.spacing FL-12334.18 0 of wood screws to prevent the splitting of wood. sir 11 or 13 f d t�unur SEE NOTE 1 O a z rrrrll t o n z V N•; KZ; N v z p a OIL i OPENNING, TYP.HEAD& a s JAMBS 28 FRAME Lv(3 c�Lj Vw h?z o �i N rl.O Z Z p coo _ Xj 1X BUCK-\ z 27 — OP.@JAMB — TYP. I REINFORCEMENT O SILL �� ¢z 0 I 1 l l ( l ( l7 l in al a SEE HINGE G SEE NOTE 1 DETAIL m (TVP.) STRIKE JAMBcl HINGE JAMB12 m INSWING FRAME ANCHORING a i o " Masonry 1X buck construction a Z g CONCRETEANCHOR NOTES: w o 1.Concrete anchor locations at the comers may be adjusted to maintain the min. p edge distance to mortorjoints. H rr 2.Concrete anchor locations noted as MAX.ON CENTER"must be adjusted to v maintain the min.edge distance to mortorjoints,additional concrete anchors 'W W C N V $ may be required to ensure the MAX.ON CENTER"dimension are not exceeded. 9 a r; 3 Concrete anchor table., I( 10 _Az EpM1CLEAANCE ANCffANCHOR M1N z r NCHORITW ® 1 4" 1-1/4" 2" 4" n o° W TAPCON / 27 �� �� wre 3/17/09 ? ELCO ® -1/4" scva: N.T.S. ° W ULTRACON NOTE l: F HVI HINGE DETAIL � owc.sr: JK m' TAPCON® 3/16" 1-1/4" 3" 1-1/2" 3/16"x3-1/4"ITWconcrete screw toe-nailed LATCH&QEADBOLiDETAIL cwc.er LFS 3 E WOOD SCREW INSTALLATION NOTES: through mullion into masonry(each face)at DPAWNG NO.: a 1.Maintain a minimum 5/8" " " edge distance.1end distance.&Io.c.spacing head and sill g P 9 FL-12334.18 a of wood screws to prevent the splitting of wood. 13 s+¢r 12 of 13 I 81LLOFMATERIALS ````��µtt*�r /////' « ITEM DESCRII'T10N BELL OF MATERIALS MATERIAL ����' ��� MATERJAL REM DESCRIPAON �y- m A I BUCK SG>=055 WOOD 50 FIBERGLASS DOOR PANEL w/STEEL REINFORCEMENT(FIBER CLASSIC FIBERGLASS �� B 2X BU K SG>=0.55 WOOD 51 FIBER CLASSIC DOOR SKIN 0.065"MINIMUM THK.FIBERGLASS FIBERGLASS - K 'Q_ r W C MAX.1/4"SHIM SPACE COMP. _ = om 52 TOP RAIL �fDi D 1/4"X 2-3/4"PFH ELCO OR RW CONCRETE SCREW STEEL 54 HINGE STILE MASONRY-3000 PSI MIN.CONCRETE CONFORMING TO ACI 55 BOTTOM RAIL COMP. '�i�•�• �`` n m E .301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE 57 LOCK STILE LVL/WOOD �/q/fel�''M+ zn 40 a G 3116"X 3-1/4"PFH ITW CONCRETE SCREW STEEL 60 FIBERGLASS DOOR PANEL w/STEEL REINFORCEMENT(CLASSIC CRAFT) FIBERGLASS o H 114'x 3-1/4"PFIi RW CONCRETE SCREW STEEL 61 CLASSIC CRAFT DOOR SKIN 0.065"MINIMUM THK.FIBERGLASS FIBERGLASS g ' Z.a 1 I/4 "x2-1/4"PFH ITW CONCRETE SCREW STEEL 62 TOP RAIL COMP, 'E$ 9Q`°a J 1/4"X 3.3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL 64 HINGE STILE WOOD K #8 X 2-1/7'PFH WOOD SCREW STEEL 65 BOTTOM RAIL V L #10 X 2-1/2"PFH WOOD SCREW COMP. L o STEEL 67 LOCK STILE LVL/4VOOD M #10 X 3PFH WOOD SCREW STEEL 70 FIBERGLASS DOOR PANEL w/STEEL REINFORCEMENT CLASSIC CRAFT RUSTIC) FIBERGLASS 8 "R: 1 EXTERIOR LITE FRAME ALUM. 71 CLASSIC CRAFT RUSTIC DOOR SKIN 0.065"MINIMUM THK.FIBERGLASS FIBERGLASS 2 INTERIOR UTE FRAME ALUM. 72 TOP RAIL COMP. 3 LTTE FRAME TRIM PVC 75 BOTTOM RAIL COMP. o 4 #10X 1-1/2"PFH SM SCREW STEEL 77 HINGE AND LOCK STILE WOOD 7 MEDIUM REACH COMPRESSION WEATHER-STRIP FOAM 80 SIDELRE PANEL w/STEEL REINFORCEMENT FIBERGLASS 8 LONG REACH COMPRESSION WEATHER-STRIP FOAM 81 ISIDarrE SKIN 0.065"MINIMUM THK.FIBERGLASS FIBERGLASS J 9 4"X 4"HINGE.097'THK. STEEL 84 STILE AND TOP RAILWOOD M 10 #10 X 3/4"PFH WOOD SCREW HINGE TO FRAME STEEL 85 BOTTOM RAIL WOODS o " 12 #10 X 7'PFH WOOD SCREW STEEL 86 INSWING SIDELITE ADAPTER PVC c is 17 PASSAGE LOCK-KWIKSETSIGNATURE SERIES STEEL 88 2XMULLION REINFORCEMENT SG>=0.42 WOOD �I m_ o r 19 HEADER JAMB SG>=0.42 WOOD 89 #9 X 2-1/2"PHi WOOD SCREW STEEL 20 SIDE JAMB SG-0.42 WOOD 21 KWIKSETDEADBOLT-SIGNATURE SERIES 980 STEELm 27 LATCH STRIKE PLATE STEEL 4.56' —�{ j 28 MULTI-POINT STRIKE PLATE STEEL r _�1 ma !" 32 DOOR BOTTOM SWEEP =PVC oof 33 INSWING THRESHOLD ALUM.COMP. 1 �� o o 35 7/16"Xl/2"STAPLE STEEL n S3Y PANELSTEEL 236' W " 40 FIBERGLASS DOOR PANEL w STEEL REINFORCEMENT SMOOTH STAR FIBERGLASS =s ~U N �W 44 HINGE STILE COMP. J9 yp HEAD d SIDE n Jamb o o 45 BOTTOM RAIL COMP. u 46 INSULATING FOAM CORE POLYURETHANE $H y 47 LOCK STILE LVL/WOOD 48 TOP RAIL COMP. 49 SMOOTHSTAR DOOR SKIN 0.065'MINIMUM THK.FIBERGLASS FIBERGLASS r 5&� w i i nno NOTE:WOOD/LVL COMPONENTS: PINE(SG>=0.42) - m atc: 3/77/09 z sour: N.T.S. INSWING °N0.or. JK m T33 hreshold aa.BY: LFS 3 DRAMNG NO.: It FL-72334.18 0 stw 13 or 73