Loading...
HomeMy WebLinkAboutBuilding Permit ApplicationALL APPLICABLE INFO MUST BE COMPLETED FOR APPUCA71ON TO BE ACCEPTED Date: Permit Number: Building Permit Application Planning and MveloymentServices Building and Code Regulation Division 2400 kRrglnla Avenue, Fort Pierce Fl. 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential PERMIT APPLICATION FOR: Shutter Address: 5313 SUNSET BLVD., FT. PIERCE. FL 34982 Legal Description: INDIAN RIVER ESTATES UNIT 07 BLK 52 LOT Property TaxID #:3402-608-0485-000-2 Lot No. 45 Site Plan Name: Project Name: RANDY & DOROTHY BURTON Setbacks Front Back RlghtSide: Left Side: Replacement Windows (13) Block No. 52 HVAC Gas Tank []Gas Piping _ Shutters Windows/Doors 11 Electric OPlumbing ❑Sprinklers ❑Generator Li Roof Total Sq. Ft of Construction: Cost of Construction: $ 21,700.00 So. Ft. of First Floor: _ Utilities:Sewer []Septic Name RANDY & DOROTHY BURTON Address: 5313 SUNSET BLVD. City FT. PIERCE State: FL Zip Code: 34982 Phone No. 772-519-0336 RII in fee simple Title Holder on next page ( If different from the owner listed above) ofconstruction Is $2500 or more, a RECORDED Name: Sam Ochstein Building Height: Company: Newsouth Window Solutions Address:2526 Okeechobee Blvd. City: West Palm Beach State:FL Zip Code: 33409 Fax: 5614784100 Phone No. 561-712-9000 E -Mail: westpalmbeachna,newsouthwindow.com State or County License: CRC1330822 Is required. Name: ---_--- Address: City: State: Zip: Phone: FEE SIMPLE TITLE HOLDER: _ Not Applicable Name: Address: City: Zip: Phone: MORTGAGE COMPANY: _ Not Applicable Name: SUPERVISOR Address: VEGETATION City: State: Zip: Phone: COUNTER BONDING COMPANY: Not Applicable Name: REVIEW Address: REVIEW City ZIP: Phone: I certify that no work or installation has commenced prior to the issuance of a permit. colt,chckein000lrtncwiarr�1Yyeppl)�cableiHomeOwners iASgOCiaetionxrulielsaulawsorandco er structure. Please consult with your Home Owners Association and review your deed for any In consideration of the grenting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucia County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residentlal use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before N Signature STATE OF COUNTYOLORIDA1M��Gy, STATE OF I COUNTYOFOFPA �Nrti�h The forgoing Instrument was acknowledged before me thBA-k dayofST 20 It by �cx1v ' lam, r�or� (Name of person acknowledging) CKUA--� (Signature of Notary Public- State of Florida ) Personalty Known OR Produced Identification Type of Identification Produced r 0 44.". L c Commission KIM A. STONE 'Ae,;d� EXPIRES: OMba 15, 2019 Revised 07/15/2014 The%cing Instru ent was acknowledged before me this day Of 20 -1 -*by (Name of person acknowledging) :�� . (Signat re of Notary PPu c- tate of Florida } Personally Known X OR Produced Identification Type of Identification Produced No. MY coM b5iury n rr.— E)IPIRES: ()OW 15, 2019 REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEATURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE COMPLETE INITIALS NewS o uth 2526 Okeechobee Blvd. " West Palm Beach, FL 33409-4006 WINDOW OLUTIOTNS 561-712-9000.561-478.4100 fax www.NewSouthWindow.com Lic# CRC -1330822 Ma/dd in Flo -da for FI da Homes y Date Jam' y- 7 To 711'17 y t I�/Y //iA�/ " H E-mail doll y_14tIP 6/*q/1 (U 5 3i 3 4vl `iP i t �yt� Home Phone 7 5 7 03 3 Cell Phone City /61 P FC t State )1�- L Zip 3 V?101 Business (Mr./ Mrs.) Replacement Windows • Entry & Patio Doors • Storm Doors • Impact Resistant Windows & Doors WHOLESALE & RETAIL WINDOW CONTRACT NewSouth Window Solutions aorees to measum. mamrfa&..: nrhumid.and—r,,:—.Heo.n....,:..............._._s_...:_�_..._a___L____. _-._.... 9 all ow dI _.__..._._.._.....__..._........ . ...— o„�oa��s oi�rvvvcv ocwrr: All NeWSotlth Vantage Series Windows Include Double Pane, Low -E glass with Argon gas, and 12 point fusion welded corners. All Vantage windows are sealed and vacuum tested for superior argon retention. Color Ootlom(whole wind Tan ❑Bronx (ettedorany) IntMor Cnlors Tan X IN Cohrs may nrysli hryfmmsample dnitial) LOW-EGLASS:366GLAS5 6340GLASS ALLSASHESAR RGON FILLED -WITHOUT EXTRA CHARGE OBSCURE GLASS ❑YES NO LOCATION: TEMPERED GLASS❑YES O I LOCATION: �l°= GRIDS Gfl1°” ❑ e%anta e ❑ ants e9000 Sin le Hun g g 9 9 jVantage 9000 Impact ❑ Other: QUA Mm A A DOUBLE HUNG E-VANTAGEpurmty ❑ (HALF -SCREEN STANDARD) O Full Screen SINGLE HUNGHUNG (OR 0aN .HUNG (HALF -SCREEN) ImWR Dnon-impact PATIO DOORS ❑Impact 0non-Impact ❑ Open Praire Grids IrMkate dtt,dme arrows krdimnian ❑5/0x6/8 09/0X6/8 of'r, owside boki:g In (oSLp 05/0X8/0 ❑ 9/0 X 8/0 ❑ 6/0 X 6/8 ❑ 12/0 X 6/8 06/0X8/0 ❑12/0X8/0 ❑ 8/0 X 6/8 ❑ 16/0 X 6/8 � O ❑ ❑ 3 2 LRE SLIDER E -VANTAGE ❑ DN, HALF -SCREEN STANDARD) D Full Screen SLIDEn)(OX oryXXO ❑ outside baking in impatt O imn�mp a ❑ 8/0 X 8/0 Cl 16/0 X 8/0 PICTUREWINOOW VANTAGE (NOSCREEN) ❑impact Ormn-Impact — 3 PANEL PATIO DOORS Dimpact Ononimpact -_ `r e 3 LITE SLIDER WITH PICTURE WINDOW Q SCREENS) ❑ impatt D nonAmpaa Ind" rte srx, dmwarraws far direction of slide ou'sMebokingln 1/4-1/2-1M mnfguration / PANEL PATIO DOORS a impact❑non-impact r_ AWNING&HOPPER ® a CASEMENT(OSLR _UFTHINGE A DOUBLE CASEMENT 000 _weir HINGE ❑Impact ❑ mn-imlucl mdkam six, tlaw arrows fordirectlondditle outside bokirg In ❑ HALF/�1 JI ❑ EYEBROW s ' ❑ QUARTER -ROUND a 0 TRAP ❑ OTHER ROUND (DRAW IN SPACE) GRID STYLES ❑ STANDARD ❑CONTOUR ❑ BRASS/GOLD/PENCIL Colonial ❑Prairie ❑Open Prairie Was Mir home bulk pdorm tgyer❑Ye to Ifyes,theundersigrwd egress tothe to and .d'Hionsofthe NewSouth Lead Safe Work PrettittsAd tlum.lf house testi portiw foriead,an Rbnai S65per/w�iMr wihbeaMd toshebalance. vkaZ ✓u Bwers9gnmure TOTAL NUMBER OF WINDOWS ON THIS ORDER: TOTAL DOORS: *" Subject to NewSouth field engineering and approval. AM 17jr nur/cPp� A{IfU a u W S r ,' PXcP A; n ❑ Customer a rees to Ne N So h I ut to )spay a yard sign until 30 days after completion. TVWYEARS FREE IN HOME SERVICE BUYER'S RIGHT TO CANCEL BUYER MAY CANCELTH IS CONTRACT BY DELIVERING WRITTEN NOTICE TO THE SELLER AT ANY TIME PRIOR TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE OF THIS TRANSACTION. BUYER MAY USE THIS CONTRACT AS THAT NOTICE BY WRITING "I HEREBY CANCEL" AT THE BOTTOM AND ADDING BUYER'S NAME AND ADDRESS. THE NOTICE MUST BE DELIVEREDTOTHE SELLER ATTHE ADDRESS SHOWN ABOVE. Total price" (/ %00 Down payment.�K��1�5 $ 0 0 Delivery/commencement. $ Balance due upon final $ window/door installation. Bank Financing 13 Cash on Completion / / NewSou ..... l A\ to / 2526 Okeechobee Blvd, West Palm Beach, FL 33409 • 561-712-9000 • CRC1330822 Property Information Owner: RANDY & DOROTHY BURTON Address: 5313 SUNSET BLVD. FT. PIERCE, FL 34982 Information Wind Zone: 170 MPH. Exposure Category: C Minimum Building Dimension: 25 ft. Mean Roof Height: 15 ft. Risk Category: II 11 Desien Pressure Calculations 11 Opening OP g Location Device Device Device Max Positive Max Negative g Number Zone Width (in) Height (in) Elevation (ft) Pressure (psf) Pressure (psi) 1 Int 72.75 49.25 7 35.6 -38.8 2 Int 35 42 7 37.7 -40.9 3 Int 43.75 43.75 7 37.1 -40.3 4 Int 35.75 49.25 7 37.3 -40.5 5 Int 35.75 49.25 7 37.3 -40.5 6 Int 35.75 49.25 7 37.3 -40.5 7 Int 35.75 49.25 7 37.3 -40.5 8 Int 71 47 7 35.7 -38.9 9 Int 72.75 52.5 7 35.4 -38.6 10 Int 35.75 49.25 7 37.3 -40.5 11 Int 35.75 49.25 7 37.3 40.5 12 Int 35.75 49.25 7 37.3 -40.5 13 Int 35.75 49.25 7 37.3 40.5 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 5th Edition (1014) Florida Building Code. Page 1 of 1 SCIS Home lag In User Registration Hot Topics I Submit Surcharge Stats & Facts Publications I FSC Stag SCIS Site Map unk 1 Search fprP Approval USER:ER: Public User Pronuct Aooroval Menu > P"dUCtm AQUICatiOn Search > 600100011 Olit > llpplioation Detail FL # FL16842-R3 Application Type Revision Code Version 2014 Application Status Approved Comments Archived O Product Manufacturer NewSouth Window Solutions Address/Phone/Email 4901 oak fair blvd tampa, FL 33610 (513)284-0129 danochsteln@newsouthwindow.com Authorized Signature Vivian Wright rickw@r bldgconsu(tants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Horizontal Slider Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer O Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Lyndon F. Schmidt, P.E. Evaluation Report Florida License PE -43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2017 Validated By Ryan 7. King, P.E. Ov Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL16842 R3 COI CERTIFICATE Of INDEPENDENCE odf Standard HAMA/ W DMA/CSA101/I.S.2/A440 AAMA/W DMA/CSA101/I.S.2/A440 ASTM E1886 ASTM E1996 ASTM E1996 TAS 201, 202, 203 Year 2008 2005 2005 2006 2005 1994 Product Approval Method Method 1 Option D Date Submitted 32/20/2015 Date Validated 01/14/2016 Date Pending FBC Approval 01/18/2016 Date Approved 04/12/2016 Date Revised D4/11/2017 Summary of Products Go to Page = 0 0 0 Page 1/ 2 0 0 FL of Model, Number or Name Description 16842.1 a. 9500 Slider XO Extruded Vinyl "Non -Impact" Horizontal Sliding Window utilizing a Nall Fin Installation (XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No F116842 R3 II Ins* 16842 1 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.1 for Design Pressure Ratings, any FL16842 R3 AE Eval 16942.1.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.2 b. 9500 Slider XO Extruded Vinyl "Non -Impact" Horizontal Sliding Window with Flange Installation (XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No ELIE042 R3 11 INST 16842 2 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.2 for Design Pressure Ratings, any FL16842 R3 AE Eva] 1684 pd additional use limitations, installation Instructions and product Created by Independent Third Party: Yes particulars. 16842.3 c. 9550 Slider XO - Impact Rated Extruded Vinyl "Impact" Horizontal Sliding Window utilizing a Nail Fin Installation (XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No EL1042 R3 ti Int 16842 ndf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.3 for Design Pressure Ratings, any ELUE42 R3 AE Eval 16842.3.pdf additional use limitations, Installation Instructions and product Created by Independent Third Party: Yes particulars. 16842.4 d. 9550 Slider XO - Impact Rated Extruded Vinyl "Impact" Horizontal Sliding Window with Flange Installation (XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R3 II Inst 16842 4 Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.4 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842 additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.5 e. 9550 Slider XO - Impact Rated - Extruded Vinyl "Impact" Horizontal Sliding Window utilizing a HVHZ Nail Fin Installation (XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16842 R3 It Inst 16842 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.5 for Design Pressure Ratings, any FL16842 R3 AE Evaf 16842 s pd additional use limitations, Installation instructions and product Created by Independent Third Party: Yes particulars. 16842.6 f. 9550 Slider XO - Impact Rated - I Extruded Vinyl "Impact" Horizontal Sliding Window with Flange HVHZ Installation (XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16842 R3 II Inst 16842 6 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.6 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842 6 odf additional use limitations, installation Instructions and product Created by Independent Third Party: Yes particulars. 16842.7 g. 9500-3 Slider XOX Extruded Vinyl "Non -Impact" Horizontal Sliding Window utilizing a Nail Fin Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R3 II Inst 16842 7 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.7 for Design Pressure Ratings, any EL16842 R3 AE Eval 16842 7 odf additional use limitations, Installation Instructions and product Created by Independent Third Party: Yes particulars. 16842.8 h. 9500-3 Slider XOX Extruded Vinyl "Non -Impact" Horizontal Sliding Window with Flange Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use In HVHZ: No FL16842 R3 II Ins+ 16R42.8.ndf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.8 for Design Pressure Ratings, any EL16842 R3 AE Eval 16842 8 odf additional use limitations, Installation instructions and product Created by Independent Third Party: Yes particulars. 16842.9 I. 9550-3 Slider XOX -Impact Rated Extruded Vinyl "Impact" Horizontal Sliding Window utilizing a Nall Fin Installation (XOX, configuratlon) Limits of Use Installation Instructions Approved for use in HVHZ: No EL16842 R3 II Inst 16842 9 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.9 for Design Pressure Ratings, any FL16842 R3 AF Eval 36842,9.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.10 �. 9550-3 Slider XOX -Impact Rated Extruded Vinyl "Impact' Horizontal Sliding Window with Flange Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No EL16842 R3 Il Inst 16842 10 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.10 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842 h n pd additional use limitations, Installation instructions and product Created by Independent Third Party: Yes particulars. 16842.11 k. 9550-3 Slider XOX - Impact Rated Extruded Vinyl "Impact" Horizontal Sliding Window utilizing a - HVHZ Nail Fin Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use In HVHZ: Yes EL16842 R3 ti Inst 16842 11 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.11 for Design Pressure Ratings, any EL16842 R3 AE Eval 16842,11.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.12 1-9550Slider XOX - Impact Rated Extruded Vinyl "Impact" Horizontal Sliding Window with Flange - HVHZ Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes EL161142 R3 ]I ]n t 16842 12 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.12 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842 f 7 dr additional use limitations, Installation Instructions and product Created by Independent Third Party: Yes particulars. 16842.13 m. DuraGard Slider XX Extruded Vi"Non-Impact' Horizontal Sliding Window utilizing a Nall Fin Installation (XX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R3 II INST16842 13 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.13 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842 13 odf additional use limitations, Installation Instructions and product Created by Independent Third Party: Yes particulars. 16842.14 n. DuraGard Slider XX Extruded Vinyl "Non -Impact" Horizontal Sliding Window ()(X, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No F116842 R3 II INT 16842 14 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.14 for Design Pressure Ratings, any ELL6842 E16842R3 AF Pyal 16842,14.pdf additional use limitations, Installation Instructions and product Created by Independent Third Party: Yes particulars. 16842.15 0. DuraGard - 3 Slider XOX Extruded Vinyl "Non -Impact" Horizontal Sliding Window utilizing a Nail Fin Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No EL16842 R3 Il INT 16842.15.odf Approved for use outside HVHZ; Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.15 for Design Pressure Ratings, any FL16842 R3 AE E ai 16842 16 odf additional use limitations, Installation instructions and product Created by Independent Third Party: Yes particulars. 16842.16 p. DumGard - 3 Slider XOX Extruded Vinyl "Non -Impact" Horizontal Sliding Window with Flange Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R3 II IN T 1684 16 pd Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.16 for Design Pressure Ratings, any EL16842 R3 AE Fyal 361142,16,odf additional use limitations, installation Instructions and product Created by Independent Third Party: Yes particulars. 16842.17 q. Sashilte Slider XX Extruded Vinyl "Non -Impact" Horizontal Sliding Window utilizing a Nail Fin Installation (XX, configuration) Limits of Use Installation InstructionsApproved for use In HVHZ: No FL16842 R3 II INST 16842 17 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.17 for Design Pressure Ratings, any EL16842 R3 AE Eval 16842,17,odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.18 r�Sashiite Slider XX Extruded Vinyl "Non -Impact" Horizontal Sliding Window (XX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R3 II INST 16542.18.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.18 for Design Pressure Ratings, any FL16842 R3 AE E al 16842.18.pdf additional use limitations, installation Instructions and product Created by Independent Third Party: Yes particulars. 16842.19 S. Sashlite - 3 Slider XOX Extruded Vinyl "Non -Impact" Horizontal Sliding Window utilizing a Nail Fin Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R3 II INST 16842 1 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.19 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.1g.odf additional use limitations, installation Instructions and product Created by Independent Third Party: Yes particulars. 16842.20 t. Sashlite - 3 Slider XOX Extruded Vinyl "Non -Impact" Horizontal Sliding Window (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R3 II INST 16842 20 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.20 for Design Pressure Ratings, any FL16842 R3 AF Eval 16847 20 odf additional use limitations, installation Instructions and product Created by Independent Third Parry: Yes particulars. Go to Page 0 0 0 Page 1/ 2 i8 Beck fflielt nnmR Us :: 2803 Rlalr StOne 11+e4 Tallahassee FL 32399 Phone: 850-487-1624 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 5 Mt• of Florida :: Privacy statement :: N'•>«ibllity Statement :: Refund statement Under Flonte law, email addresses are public records. If you do not want your e-mail address released In response t0 a public -records request, do not send electronic mall M this entity. Instead, contact Me office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. 'Pursuant M Section 455.275(1), Florida Statutes, effective October 1, 2012, Ilcensees licensed under Chapter 455, F.S. must provide the Department with an email address If May have one. The Amelia provided may be used for official communication with the licensee. However small addresses are public record. If you do not wish to supply a personal address, please provide Me Department with an email address which can to made available to Me public. To determine If you are a licensee under Chapter 455, F.S., Pleases click here . Product Approval Aocepte: = AN Credit Card Safe P:PIMIHew $ouH: WIMMs FEpNMWTN RR PptuQ PPPw M!14WZ HmY f SMIAC- Om. LVL-IW2 (}010)IjL-IWOLS6.NIg, R-IWL6 fn A W N V LTJ _ 0. 3 v a GT 0 m 3 U sunT�ww�j 0•o � �� .n 3 c a /c a m 3 m yc �+IOlt fIm<-I m0 �a ?3 [LQ O Q g@3g4 VS. m'm as �0 � Z� 5'm�,S 3 cm » merr o 'a O vm op 3< C' m� p _ 3 �F. pa ao a Et am $ �m@ �� apo pn 2� )lb v7 coO m 3 (n1 � z$ m O� an Op m A ma a� OA mn mn 4 'a m3 m�� ► D y ui"' < Q Re pO �o fO$ nn mo 7 ►yT1 0a � ffi � — ms 1 m a m a m = X `fin 3, N O p� C N2 O m 10 o m p m � p a N a j. 6P MAX.OVERALL FLANGE HEIGHT m int x m s Gl i y R' m V$G� S yl �l O IM $ ./ N80.9/0B •1'• R$ :. IM iH1pWLT: Omer,w�b pepwaa el+ i� 3 � NewSooFh Syndwn F. svM1mHR �, '�0180�•: •'`�` IWp P.E N.. H368p ',,/I//I��fI^Ijlllll `` A A y 0 2 1 i] 15 NOOE1- NAN A00 mAZI M P COR A85LMBLY: BUIlDINO CONSVLTN INC. N je N 1 8 ?5 IS UPMTE 10 5TH ED. 281{ i9c Ifs �/T// DATE gy TYPIGL ELEVATION. OESCN Y{{�/ P.o. L 230. valnw. PL s5sas PREF. NR6 ♦k ( NAL NSE'$ PMn. N. 813.659.9197 R 510 ,FHPE CA No. 9813 O ao1 a H,w, eu�.m.9 99wu...wro IHe. j^ 63' MAX. FRAME H9GHf O � N ww��g F F F F 4 X R10r1Mw.sau YAile�w AworrA-wasi¢.ftp w •uwxurW SkW-YYpy4t/HpOp1V�•tYQ.lasqu Y yyy 14 n• • • a • b • QQ� A T �\ N+ N V N V Q a w p u � P N 7, a A O 30 N ^ $ a 0 d 0 • a e. . • Y Y a LV,rMN. A. w s a v .q . SAL � a tBNCMK ln►d N _ ft4M y � ! 8 INwsautlr Y CN anwr a At6nan tw31d6m o�HNK,twm a iw w t iERIKN. & NORMwm W Pa tlw ¢lpr Vtl�bw M 3306 piDSS SOCIIOIa p= wa et""I" Nt3 ut � w.w. Piwow aexrwrwwn me. WMAX or- (TYN € a� r wda�oo A F C q/� a�3ly� u # ou a ooxwx»xo. Mc mit I BUCK ! FRNE YY ►m s. tm. wn... n aaeae AKCfKMO1D Hsi suNPAtn fri .., M6WW* I. vI MWe1M-I TM .h oodff YQIbYaY1 mw- MMWL1Y{t PfM1Y�'tYQ166.4 it e �I E:\Melm New 6auln Wi oe RWANE" Roman uR MPBI'an1R-11W2ll t lSWeAC-paw Pg-IW2(2014)1 142,1 .a R -16e26 A m O s 3 O DEE 3n 3� c=Et ip a Z Q, O's a0. uv < 06, Fm vo s 3 -'m 3 a o m o 3 m a 3 m oy ?� xPa oa �a n C y m ^ ro �s -mn �n A m AE P• Q o o m n a m o m Q z$ ° o• 8 m � ire o 3 Et m ^ o n A Z 69r MAX OVERALL FLANGE HEIGHT xz g m a z m F 0 4 m' x X � N3 EF L7 x G Si 'o o° f0 a� 0 u `No 11111 ... Ye �� � •mow .?' � NB. e3,BB •: PROWCT: OeawMb NspmH er .� •••, NBwSOuth ynaw� E, svnmlat '� .RaeoA� �V``` = b T 1 i] 15 ME MOOR NMI AOO JK IINIII11E11nn PART OR ASSENWY' q�� BUIIDINp CONAILTNMS, INC. UPWTE }p SIH Ep, 2014FBC !i5 I/N p.0. Bm p3p, Velrlco, R 33595 m {• NO DATE gy TYPIGL ElEVA710N, OESICN "' Pnwnw Nw.: 813.6 59.9197 SON PRESSilR6 NOTES .F9pE CA No. 8813 0 9019 w.W. BWao.iuo OeN.ui��rrt� Iw. 63• MAX. FRAME HEIGHT O X A ate! m �! AL ft.340 FL J.11OS or— rryRa oypj ffi G � Me.aroa i Ricoucr. e'= NeeSaM {ynaen R. aenean ��i� i 3 3 R.c Ms. urn ii � ? m ,rrrrpnnna�"• RwR art �llelY: AMDNo =I v4I erc. A ' 14 BUCK d iRAl1E R.0. sm� a]U, .. M.9 rl aaeoa Rnee. wna.aa3 0 or— rryRa oypj ffi G � Me.aroa i Ricoucr. e'= NeeSaM {ynaen R. aenean ��i� i 3 3 R.c Ms. urn ii � ? m ,rrrrpnnna�"• RwR art �llelY: AMDNo =I v4I erc. A ' 14 BUCK d iRAl1E R.0. sm� a]U, .. M.9 rl aaeoa Rnee. wna.aa3 .roc c.w rae. "13 O ao� � e.w. ewmme oawwn�.rne iwa. r---rOr 0] I xsaw I:S7■ tib I�i� _. .... .. �.. G 7. 3 e p0 V PNL W N�OV O V PNt W N�P=r�n =e OnO L3t� 111RI gill Q x� x Fig e F H all 1111 D �0 o � a 43401 ;a�4�$3 � ! 3 Msaufh=uun="- X MW a ,�aa2 euanwo eo=a27ANM ec P.0. Bm 270. Vatrbe, R 316e6 °i � P� uw e=a_aawoin RW R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O. Box 230 Valnco, FL 33595 Phone 913.659.9197 Florida Board of Professional Engineers Certificate of Authorintion No. 9813 Product Sub Category Manufacturer Product Name Category NewSouth Window Solutions 9550 Slider XO Windows Horizontal Slider 4901 Oak Fair Blvd Impact Rated - HVHZ Tampa, FL 33610 w/ Flange 813 626-6000 Scope: Product Evaluation report issued by R W Building Consultants, Inc. & Lyndon F. Schmidt, P.E. (System ID # 1998) for NewSouth Window Solutions, based on Rule Chapter No. 61G20-3, Method 1D of the State of Florida Product Approval, Dept. of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 5th Edition (2014) Florida Building Code (FBC) including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the "HVHZ", this product complies with Section 1626 of the FBC and does not require an impact resistant covering. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL -16842.6 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL -16842.6 for size and design pressure limitations. Supporting Documents: 1. Test Report No. TEL 02031488 TEL 02031489 2. Miami Dade NOA 14-0423.16 3. Drawing No. No. FL -16842.6 Test Standard Testing Laboratory TAS 201, 202, 203-94 Testing Evaluation Lab. TAS 201, 202, 203-94 Testing Evaluation Lab. Materials Testing Saflex° PVB Intedayer (Eastman Chemical Co.) Prepared by RW Building Consultants, Inc. (CA #9813) 4. Calculations Prepared by Anchoring RW Building Consultants, Inc. (CA #9813) ASTM E1300 Glass Load Lyndon F. Schmidt, P.E. 5. Quality Assurance ��� %':��C Certificate of Participation issued by National Accreditation and * • • No 43409 Management Institute, certifying that NewSouth Window Solutions is manufacturing products within a quality assurance program that complies e with ISO/IEC 17020 and Guide 53. =p'.. STATE OF O 40, Sheet 1 of 1 Signed by William B. Shelton, P.E. William B. Shelton, P.E. Signed & Sealed by Lyndon F. Schmidt, P.E. Signed & Sealed by Lyndon F. Schmidt, P.E. Lyndon F. Schmidt, P.E. FL PE No. 43409 1/13/2016 8✓12017 Florida Buildng Code Online, ®. Business & ProfessionalRegulation �^ BM Home I Log In I User Reglstmdon I Hot Topic Submit Surcharge Stats a Facts ! Publications FBC Staff BCLS Site Map Links I Seamh prProduct Approval USER: Public User Product Approval Menu > Pmduct or Application Search > Application List > Applkrtbn Detail FL * FL16851-R4 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer NewSouth Window Solutions Address/Phone/Email 4901 oak fair blvd tampa, FL 33610 (513) 284-0129 da nochstei n@ newsouthw i ndow. com Authorized Signature Vivian Wright rickw@rwbidgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F Schmidt the Evaluation Report Florida License PE -43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2017 Validated By Ryan 1. King, P.E. e Validation Checklist - Hardcopy Received Certificate of Independence FL16851 R4 COI CERTIFICATE OF INDEPENDENCE.odf Referenced Standard and Year (of Standard) Standard Year AAMA/WDMA/CSA101/I.S.2/A440 2011 AAMA/WDMA/CSA101/I.S.2/A440 2008 ASTM E1886 2005 ASTM E1996 2006 ASTM E1996 2009 TAS 201, 202, 203 1994 Equivalence of Product Standards Certified By Sections from the Code Nf„a —1— 1— .,.,..1N amnnTCTNAVPeorW irnt XAPXOiirnanpuanpuan vd 6/1/2017 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Florida Building code seine Method 1 Option D 02/14/2017 02/16/2017 02/21/2017 04/04/2017 FL # Model, Number or Name Description 16851.1 a. 9400 Single Hung Window Extruded Vinyl "Non -Impact" Single Hung Tilt Window New Construction with Nail Fn (DIX - configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL16851 R4 11 INST 16851 1 odf Verifled By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.1 for Design Pressure Ratings, any FL16851 R4 AE (a) EVAL 16851.1.odf additional use limitations, Installation Instructions and Created by Independent Third Party: Yes product particulars. 16851.2 b. 9400 Single Hung Window Extruded Vinyl "Non -Impact" Single Hung Tilt Window with Flange (O/X - configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No FL16851 R4 II INST 16851 2.odf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.2 for Design Pressure Ratings, any FL16851 R4 AE (a) EVAL 16851.2.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 16851.3 c. 9450 Single Hung Window Extruded Vinyl'Impact" Single Hung Tilt Window New Construction with Nail Fn (O/X - configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16851 R4 II INST 16851.3.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.3 for Design Pressure Ratings, any additional use limitations, installation instructions and FL16851 R4 AE (a) EVAL 16851.3.odf Created by Independent Third Party: Yes product particulars. 16851.4 d. 9450 Single Hung Window Extruded Vinyl "Impact" Single Hung Tilt Window with Range (O/X - configuration) Limns of Use Installation Instructions Approved for use in HVHZ: No FL16851 R4 II (a) INST 16851.4.odf Approved for use outside HVHZ: Yes Verifled By: Lyndon F Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A EvaWation Reports Other: See INST 16851.4 for Design Pressure Ratings, any FL16851 R4 AE (a) EVAL 16851.4.ndf additional use limitations, installation Instructions and Created by Independent Third Party: Yes product particulars. 16851.5 e. 9450 Single Hung Window Impact Extruded Vinyl "Impact" Single Hung Tilt Window New Rated - HVHZ Construction with Nail Fin (O/X - configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16851 R4 II INST 16851.5.odf Approved for use outside HVHZ: Yes Verifled By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.5 for Design Pressure Ratings, any FL16851 R4 AE (a) EVAL 16851 5 odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 16851.6 f. 9450 Single Hung Window Impact Extruded Vinyl "Impact" Single Hung Tilt Window with Flange Rated - HVHZ (O/X - configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16851 R4 II (a) INST 16851 6 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 here /Jr,i�hnilAinn ,vn/nr/nr .nn M1 2/4 6!1/2017 Florida Building Coda Online Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.6 for Design Pressure Ratings, any FL16851 R4 AE (a) EVAL 16851 6 odf additional use limitations, Instalfation instructions and Created by Independent Third Party: Yes product particulars. 16851.7 g. 4400 Single Hung Window Extruded Vinyl "Non -Impact" Single Hung Window New Construction with Nail Fin (0/X - configuration) Limits of Use Installation Instructions Approved for use In HVHZ: No FL16851 R4 II Inst 16851.7.odf Approved for use outside HVHZ: yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.7 for Design Pressure Ratings, any FL16851 R4 AE (a) EVAL 16851.7.odf additional use limitations, installation Instructions and Created by Independent Third Party: Yes product particulars. 16851.8 h. 4400 Single Hung Window Extruded Vinyl "Non -Impact' Single Hung Window with Flange (0/X - configuration) Limits of Use Installation Instructions Approved for use In HVHZ: No FL16851 R4 II INST 16851.8&Lif Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.8 for Design Pressure Ratings, any FL16851 R4 AE (a) EVAL 16851.8.odf additional use limitations, installation Instructions and Created by Independent Third Party: Yes product particulars. 16851.9 1. 4450 Single Hung Window Extruded Vinyl "Impact" Single Hung Window New Construction with Nail Fin (O/X - configuration) Limits of Use InstaRstion Instructions Approved for use in HVHZ: No FL16851 R4 II Inst 16851.9.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.9 for Design Pressure Ratings, any FL16851 R4 AE (a) EVAL 16851.9.odf additional use limitations, Installation Instructions and Created by Independent Third Party: Yes product particulars. 16851.10 j. 4450 Single Hung Window Extruded Vinyl "Impact" Single Hung Window with Flange (O/X - configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16851 R4 II Inst 16851.10.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.10 for Design Pressure Ratings, any FL16851 R4 AE (a) EVAL 16851.10.odf additional use limitations, installation Instructions and Created by Independent Third Party: Yes product particulars. 16851.11 k. 4450 Single Hung Window Impact Extruded Vinyl "Impact" Single Hung Window New Rated - HVHZ Construction with Nall Fin (0/X - configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16851 R4 II (a) INST 16851.11.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.11 for Design Pressure Ratings, any FL16851 R4 AE (a) EVAL 16851.11.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 16851.12 1. 4450 Single Hung Window impact Extruded Vinyl "Impact' Single Hung Window with Flange Rated - HVHZ (O/X - configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16851 R4 11 Inst 16851.12.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.12 for Design Pressure Ratings, any additional use limitations, installation Instructions and FL16851 R4 AE (a) EVAL 16851.12.odf Created by Independent Third Party: Yes product particulars. 16851.13 in. 4000 Twin Single Hung Window Extruded Vinyl "Non -Impact" Twin Integral Mulled Common lamb Single Hung Window New Construction with Nall Fin (O/X I O/X - configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16851 R4 11 (a) INST 16851 13 odf httm //flnridaheldinn nrn/rr/rr arm Aid 6(1/2017 Florida Building Code Online Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.13 for Design Pressure Ratings, any FL16851 R4 AE (a) EVAL 16851.13.Ddf additional use limitations, installation Instructions and Created by Independent Third Party: Yes product particulars. 16851.14 n. 4000 Twin Single Hung Window Extruded Vinyl "Non -Impact' Twin Integral Mulled Common Jamb Single Hung Window with Flange (O/X I 0/X - configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16851 R4 II (a) INST 16851,14.01' Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.14 for Design Pressure Ratings, any FL16851 R4 AE (a) EVAL 16851 14 odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 16851.15 o. 4000 Triple Single Hung Window Extruded Vinyl "Non -Impact" Triple Integral Mulled Common Jamb Single Hung Window New Construction with Nail Fin (DIX I O/X I O/X - configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16851 R4 II (a) INST 16851.15.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.15 for Design Pressure Ratings, any FL16851 R4 AE (a) EVAL 16851 15 odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 16851.16 p. 4600 Twin Mulled Single Hung / Extruded Vinyl "Non -Impact" Twin Integral Mulled Common Picture Window lamb Single Hung / Picture Window New Construction with Nall Fin (O/X 10 - configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16851 R4 II (a) INST 16851.16.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.16 for Design Pressure Ratings, any FL16851 R4 AE (a) EVAL 16851 16 odf additional use limitations, Installation instructions and Created by Independent Third Party: Yes product particulars. 16851.17 q. 4600 Twin Mulled Single Hung / Extruded Vinyl "Non -Impact" Twin Integral Mulled Common Picture Window Jamb Single Hung / Picture Window with Flange (O/X 10 - configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16851 R4 II (a) INST 16851.17.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.17 for Design Pressure Ratings, any FL16851 R4 AE (a) EVAL 16851.17.odf additional use limitations, installation Instructions and Created by Independent Third Party: Yes product particulars. Back Nett Contact Us :: 2641 Blair Stone Road. Tallahassee FL 32399 Phone: 8511-487-1824 The State of Florida is an AAIEW employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mall to this entity. Im[ead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1), Florida statutes, effective October 1, 2012, licemess licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The malls provided may be used for official communication with the Hemet. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made avallable to the public. To determine if you are a licimee urMer Chapter 455, F.S., please click bem_. Product Approwl Acoepts: ®&� Credit Card Safe mail S IM1Wodm PERMANENM- Handle PnXJWAPq WL -16851 Single Hung%C O IrgAH 16851(2014F1-16851.1tidwg. 11-16851.6 nig 0 O G $ O0 J az 3 c 5'01 x . Sc 4i4 gyp 00 S C m C 6� 2 9 2 r Q fib .ac' �� ?0 �o� O '�1 C_00 W 4 u r 3 0 ° c & — S3 fit oM oS o< �w Do -• z 0 y 3 �vr m' o W m v cm 06 0 o ff' 3 'aa 90 a Z T � � � .4 � 00 59 - &� 08 O y .Z � a g�g 9 � m C n g O F; 77 RN HEIGHT c 2 c x V F 4 ®. 0 v° u sa 0 <V 0 � 48 pp yL 44 O O \\\g11(1$CIIy11�///////i LIiX � u. dv98 Z/Y/ =*� * •i* V Z PRODUCT: Px mm4 F aporee W. _ I A 9 2 \ J4 2 13 17 a 19 I6 DDDED J7x82 NGDOW SIZE LF$ SINGLE HUNG WINDOW P.E. Ne. P 13I091� //\\O\,`` EIISE ANCHO Q u y n 2 12 17 15 GLAZING DETAIL JK PART OR ASSEMBLY: BI)9DING CONSURANTB. INC. je H 1 8 26 15 UPOATE TO 5TH ED. 201{ FBC LFS P.O. Be. 230. VaNeo. R 35585 O1 a e NO DATE PRESSURES & GENERALCAL ELEVATION, ENLGN Rur OIE$ Plnne Ne.: 811859.91 W REVISIONS MPE CA. NIS 9813 em�erx...... ��acxe lue. P to A 41 IJ x r m t� m �Bpoo a:_ �9•pa� >C O � �3�d o OT QQ p MA1 OVERALL 76' MAIL FRAME HEIGHT >C O � '�1 0.tQIenM1lMwSouBl WYtlow3 MiBMN'IFNIN- ilwltl. Raducl 1ppwBliL-i$at 9ngM Nw9t�' pµ�pljL'1661 p$gli4tN5l1iEwp Z-1 X a O !9� In • � e • S n Aa � Na N+ N� < R T N w N � m N a w C1 N N a 8 a � w a 3>R NN O A kg%g t N GO r N r n3� n aRagA Y S a o m 4 O A 1 N N Q r Q N w fiN1 � � g R- N p: T P a 1-1/f NW. 1 MOW JTrrSZ IIIN001Y SIZE SFS SINGLE HUNG B111WW , ZZ///IIt11111tt\,\ +213%7 B ItNd10 ING I JN 2 1 IT IS GL1Z3q OEfNI JI( PMf OR ASSEMBLY: Bl3ll1W0 CONlULTANIB, B1C 1 12=31MMTE TO 31N W. 014 M IFS VERTICAL HORIZONTAL I� C1 x i0 • PA. Wa M. V.Y % R J36YB Plwn� Me.: B3.B 1BYAIW 1"' NU BY SECTIONS CROSSFBPE KLVIWN� CA Na W13 rola 11.w. �uaew auwws�w.s Iwo. X O oll 0.1MnOVbw 5•uM T!•baP• PERMANEMIA-rww RaauOAGVtPMM-lfil51 Silpk Nugtc- pwwglVl-1�3 p0l•ATL-168511aA+8 3-z _. • !Z w• wr N � N 4.1 a M wN V A SN 3G w x g n O a = 3 v b iias N q P Q O � • N P. O 111 A O •P _ MXMIK 1-1/l MN. Da.f".) FM& f1TPJ � •,VflA�l►e tw�.:l!lgaaa'' �j.e _. q xwa*ezre r`1 SINUIE NUNU WINOUw ITW. .P 8tlntbl iia• �„ ��` L 1 4V4*4 PE JJK PART OR ASSEMBLY: 511Lp1< 001151A.TAWMBC Ii5�P.O. ttw 2lO. VWb, R JJSB6 ° w � ONS Pnw» rb.: suaea.atn KLvibwm!!PE C.11 11w Ylttl aota B.w. BUYLIw m�•u�turtP twv. w enwrEunl.0aW BwunAmw•AAfL-16flS15YNM Mun9K- pwYg1VL-16851 OOLg6l-1NS]J6Cy 4] S+ N ,e a SL a -� I- o°\fwu�►."""" G t lf f L*� R y g PNOOIICf:� '� +� }I P P SINGLE MUIM WINDOW 1J 17 AlIOm 37x82 WINDOW SIZE lFs P.E Na AJ600 1I \\ J f 19 13 RLYSE ANCNORAIC JII ,1j111111111\\\\\ i y b 2 1 17 IS GIA231O O m JN PARE OB ASSE8IBLY: �p ^"PRDIW CONeL1LTNrtl. NC. x iq _. 1 6 6 t UPO\TE ro STN -m. m1{ f3C IFS ✓�. PA. ll < M. vaxleo. Ii. 33603 la m t �. BUCIf A: FRAME PN R - 013.000.0107 ANCNORMO I C N0. 0013 O sa � � e.w. sunnu.e oeruv.«n wo &nMNYrbYM1 71 /^� I I-,—, a c 1 Z'7 2�l i Y 4 Q 9 M 4 IIGrvxrry � HUNG WOOW BULDINO COHIIULTANI4. W. P.O. Sm 270. VOIH04. M 77Y96 Mom Nes OMMA197 FBPE CA Ho. M17 umun.. a.w Fioaue mwW\R-]ABS154iuM Xunp\G- pwYgfL-16Kt fAMV\-Sb851lihD 63 1mPOORVIMjl Fix 36 n �B �i K qL;o _j o q N V V a S AMA 2.y g Paooucr: • f+..... •' SINGLE NUNO MINBOW WWF. F. I a N24_t 3 SIZE LFS P.E ANI9A7RM,G JNw ASSEOBLr: BIAlDB10 Tom• W. I1P0\R 10 31N W. 2014 FBL: IFS Bfu W� �% P.O. eoP M. va . n JBBBB f , AND (RAZING OEfi1L5 wwn. Ne.: efJ.eeoAfoz PBP6 C,l Ne. OBIS ♦�� +0,1 . S G1 T T O n O a am �2 ��� ;tl; �Ennn�P/f3nn 1mPOORVIMjl Fix 36 n �B �i K qL;o _j o q N V V a S AMA 2.y g Paooucr: • f+..... •' SINGLE NUNO MINBOW WWF. F. I a N24_t 3 SIZE LFS P.E ANI9A7RM,G JNw ASSEOBLr: BIAlDB10 Tom• W. I1P0\R 10 31N W. 2014 FBL: IFS Bfu W� �% P.O. eoP M. va . n JBBBB f , AND (RAZING OEfi1L5 wwn. Ne.: efJ.eeoAfoz PBP6 C,l Ne. OBIS ♦�� +0,1 R R W Building Consultants, Inc. WConsulting and Engineering Services for the Building Industry B n P.O. Boz 230 Velnco, FL 33595 Phone 813.659.9197 CFlorida Board of Professional Engineers Certificate of Authorization No. 9813 Product Sub Category Manufacturer Product Name Category NewSouth Window Solutions 9450 Single Hung Window 4901 Oak Fair Blvd Impact Rated - HVHZ Windom Single Hung Tampa, FL 33610 wr Flange 813 626-6000 Scope: Product Evaluation report issued by R W Building Consultants, Inc. & Lyndon F. Schmidt, P.E. (System ID # 1998) for NewSouth Window Solutions, based on Rule Chapter No. 61G20-3, Method 1 D of the State of Florida Product Approval, Dept. of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 5th Edition (2014) Florida Building Code (FBC) including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the "HVHZ", this product complies with Section 1626 of the FBC and does not require an impact resistant covering. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL -16851.6 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL -16851.6 for size and design pressure limitations. Supporting Documents: 1. Test Report No. 09937.02.401-18 TEL 02031487 TEL 02031566 TEL 02031722 2. Miami Dade NOA 15-1201.11 3. Drawing No. No. FL -16851.6 Test Standard TAS 201, 202, 203-94 TAS 201, 202, 203-94 TAS 201, 202, 203-94 TAS 201, 202, 203-94 Testing Laboratory Architectural Testing, Inc. Testing Evaluation Lab. Testing Evaluation Lab. Testing Evaluation Lab. Materials Testing Sagex® PVB Interlayer (Eastman Chemical Co.) Prepared by RW Building Consultants, Inc. (CA #9813) 4. Calculations Prepared by Anchoring RW Building Consultants, Inc. (CA#9813) ASTM E1300 Glass Load Lyndon F. Schmidt, P.E. 5. Quality Assurance Certificate of Participation issued by National Accreditation and Management Institute, certifying that NewSouth Window Solutions is manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. Sheet 1 of 1 Signed by Shawn G. Collins, P.E. William B. Shelton, P.E. William B. Shelton, P.E. William B. Shelton, P.E. Signed & Sealed by Lyndon F. Schmidt, P.E. Signed & Sealed by Lyndon F. Schmidt, P.E. ��ttlenalp/ F. SCHIv;/0 It,,'i :`�• ••t `o 43409• 9 • STAT E OF� -1ij' ��� F '•; O F 1 �;.• ��,�� Lyndon F. Schmidt, P.E. FL PE No.4/2017