Loading...
HomeMy WebLinkAboutProduct Approval r BCIS Home j Log In g User Registration j Hot Topics k Submit Surcharge Stats&Facts Publications FBC Staff j BCIS Site Map {. Links Search j Product Approval db r .USER:Public User ua; `zati„mi Predurt Al+nhval?`1em�.>Frgduci nr A,^,,lir n Search,>ALiratinnList>Application Detail FL# L12796 R7 - ..as Y ? Application Type Code Version 2014 Application Status *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived C.71-11 Product Manufacturer JELD-WEN Address/Phone/Email 3737 Lakeport Blvd Klamath Falls,OR 97601 (800)535-3936 fbcl@jeld-wen.com Authorized Signature Kaede McLaughlin fbcl@jeld-wen.com Technical Representative JELD-WEN Corporate Customer Service Address/Phone/Email 3737 Lakeport Blvd. Klamath Falls,OR 97601 (800)535-3936 customerserviceagents@jeld-wen.com Quality Assurance Representative Address/Phone/Email Category C:: Exterior Doors Subcategory Sliding Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 01/22/2016 Date Validated 01/25/2016 Date Pending FBC Approval Date Approved 01/26/2016 Date Revised 06/27/2017 Summa of Products FL# Model, Description Number Name 12796.1 P emium Sliding Patio Door(3800) 142 5/8"x 79 1/2"(OXXX) Atlantic Vinyl Limits of Use Certification Agency Certificate Approved for use FL12796 R7 C CAC NI011SI727.04-RI.pdf in HVHZ:Yes Quality Assurance Contract Expiration Date Approved for use 02/28/2020 outside HV •Yes Installation Instructions Impact FL12796 R7 II PAV SPD OXXX 142.625 x 79.5 SS 2015-07-10.pdf Resis t:Yes Verified By:Alexis Spyrou,PE 68101 Des' n Created by Independent Third Party:Yes Pres ure: +65/-65 valuation Reports Othe . FL12796 R7 AE PER3087.pdf Created by Independent Third Party:Yes 12796.2 Premium Sliding Patio Door(3800) 190 5/8"x 95 1/2"(OXXX) Atlantic Vinyl Limits of Use Certification Agency Certificate Approved for use FL12796 R7 C CAC NI011479-Rl.pdf in HVHZ:Yes Quality Assurance Contract Expiration Date Approved for use 12/31/2020 outside HVHZ:Yes Installation Instructions Impact FL12796 R7 II PAV SPD OXXX 190.625 x 95.5 SS 2015-07-10.pdf Resistant:Yes Verified By: Hermes Norero,PE 73778 Design Created by Independent Third Party:Yes Pressure:+50/-50 Evaluation Reports Other: FL12796 R7 AE PER3090.pdf Created by Independent Third Party:Yes 12796.3 Premium Sliding Patio Door(3800) 186 3/4"x 95 1/2"(XXXX) Atlantic Vinyl Limits of Use Certification Agency Certificate Approved for use FL12796 R7 C CAC NI011480-Rl.13df in HVHZ:Yes Quality Assurance Contract Expiration Date Approved for use 12/31/2020 outside HVHZ:Yes Installation Instructions Impact FL12796 R7 II PAV SPD NF TF 186.75 x 95.5 SS 2015-07-31.pdf Resistant:Yes Verified By: Hermes Norero,PE 73778 Design Created by Independent Third Party: Yes Pressure: +50/-50 Evaluation Reports Other: FL12796 R7 AE PER3089.pdf Created by Independent Third Party:Yes 12796.4 Premium Sliding Patio Door(3800)71 1/2"x 79 1/2"(XO) Atlantic Vinyl Limits of Use Certification Agency Certificate Approved for use FL12796 R7 C CAC NI011478-Rl.pdf in HVHZ:Yes Quality Assurance Contract Expiration Date Approved for use 12/31/2020 outside HVHZ:Yes Installation Instruction's Impact FL12796 R7 II FL12796 R5 II Premium Atlantic Vinyl SPD 71 5x79 5 Installation Instructions.pdf Resistant:Yes Verified By: Hermes Norero,PE 73778 Design Created by Independent Third Party:Yes Pressure: +65/-65 Evaluation Reports Other: FL12796 R7 AE PER3088.120, Created by Independent Third Party:Yes 12796.5 Premium Sliding Patio Door(3800)71 1/2"x 79 1/2"(XO) Atlantic Vinyl Limits of Use Certification.Agency Certificate Approved for use FL12796 R7 C CAC NI010727-R3 NI010727 01-R3 Certificatej df in HVHZ:Yes Quality Assurance Contract Expiration Date Approved for use 06/30/2020 outside HVHZ:Yes Installation Instructions Impact FL12796 R7 II PAV SPD NF TF 71.5 x 79.5 NCTL210-3710-1B SS 2015-07-31.pdf Resistant:No Verified By: National Accreditation&Management Institute r THROUGH FRAME MIN.Ur.';OCE INSTALLATION i FROM EDGE 3:- ) EMBs➢HENT � ' i=0 ^ 11/2'MIN. 1/4"SHI MAX Q E L6 v4'RAx � EMBEDMENT— SHIMSPACE 7 10" Q.G. MAX. 5 1/8" b 9 Q scan!aheE i THRU JAMB — MAX. FROM" If MIN.DISTANCE z �LLLJJJC �oea� ' a CORNERS FROM EDGE3/4' T- 17 3/16 THRU O.C. MAX. 4smD0+gsJAMBS6Lis armG 2o.6- 18 o.6—1 2MIN.DISTANCE. . FROM EDGE:34' I! Lp UJ W j r GLAZING DETAIL _ � t I ! WOOD FRAME SECTION(TYP) ` 1 0 iVERTICAL SECTION i o " FRAME JAMB SECTION(TYP) 6 1/8 HORIZONTAL SECTION j L IMAX. FROM CORNERS I` DOOR WIDTH (142 5/8" MAX.) �. f TYPICAL ELEVATION WITH FASTENER SPACING �Q s qM�srecE _......__..______-..-.--. . ............_..-- .......-..........-----.._..__...._-..._.._..------....._._...................__..._... TWO,THREE AND FOUR PANEL ;I CONFIGURATIONS APPROVED 2 b t tz MIa M3E➢MEN Max Frame I dP RATING IMPACT MIN.DTSTSN�E-I--I ' 111425/8" x791/2"I +65/-65 YE5 { FROM EDGEt 3/4' 3 I .... ............ ..._ ............,.........._......_....,.................._..................._.........................._.,.....-.t_....._......_..._....__...-._......._..__...............__.._....................._......_.._.._.........._.........._._..._.._._..._.._..___.................__t....._................._.__.__.___._._.........................._.._..._............._....._-_................................_..._..........__.... __..__.._....._.� Installation Notes: General Notes: 1. Sear flangeltame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria of 2. Use(2)-910 PH or greater fastener through the frame per location with sufficient length to penetrate a the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida minimum of 11/2"into the wood framing. For 2x wood frame substrate(min.S.G.=0.42). Building Codes(FBC)and the industry requirements for the stated conditions. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all,loads 2. All glazing shall conform to ASTM El 300. to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing is 4.7 mm tempered-8.8mm airspace-4.7mm heat strengthened glass-2.2mm project of installation. SGP-4.7mm heat strengthened glass. 4. Use structural or composite shims where required. 5. Maximum sizes are buck sizes and do not include fin or flange. anchor the window to achieve s schedule addresses l ateddes gy the n pressure upsteners uto theired nsize limitations �.� �S`F noted. It is not intended as a guide to the installation process and does PROJECT ENGINEER; DATE: 3737 Lakeport Blvd not address the sealing consideration that may arise in different wall : '•` '• `� �� -' 07/05/2014 O DRAWN BY: SCALE: TMDVENK[amath Falls,OR.97601 conditions. For the complete installation procedure,see the instructions ZO 7 D.Vezo IVTSW Phone: (800)535-3936 packaged with the window or go to _ * * = CHECKED BY: TITLE: www.jeld-wen.com/resourcestinstallation. o T T J. Kantola P• ;�w` APPROVED BY: Premium Atlantic Vinyl Sliding Patio Door OXXX DISCLAIMER: O� •.• ( Q This drawing and its contents are confidential and are not to be � s N,OTe' �� PART PRO E No: reproduced or copied in whole or in part or used or disclosed to others F �D p••• D X601 except as authorized by JELD-WEN Inc. sea DfftiEJ J ° B 04 to ase INCTL210-3803- FBCrJ IVenice FL "^D owc.No.: REv: oo SHEET OF 4 pPt91Yt�