Loading...
HomeMy WebLinkAboutProduct Approval NOTICE OF PRODUCT CERTIFICA;TIO;N Q��1 V ncc�F i�oy CERTIFICATION NO: NI008081-R7 DATE: 06/03/2007 CERTIFICATION PROGRAM: Structural COMPANY: WiWinTech CODE: 583'-1 pao°� a . REVISION DATE: 03/01/2017 To verify that the"Notice of Product Certification"is valid,please visit www.NAMICertification.com to assure that the product is active and currently listed This certification represents product conformity to the applicable specification and that certification criteriahas been satisfied. A NAMI approved certification label must be applied to the productto claim certification status. Please review and advise NAMI if any corrections are required to this document. i COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION ViWinTech Windows and Doors Series`ISL 5100 i D115275";Tilt Impact 1 2400 Irvin Cobb Drive Rated Vinyl Double Hung Prime Window Paducah,KY 42003-0588 Configuration:X/X Glazing:IG-1/8"Annealed Glassh aminate-1/8" Annealed Glass/0.090"DuPont Butacite®PVC/ 1/8"Annealed Glass Frame: W-1320mm(52") H-1900mm(75") Sash: W-1250mm(49.25") H-930mm(36.63") SPECIFICATION PRODUCT RATING AAMAMDMA/CSA 101/I.S.2/A440-05 H-R701320 x 1900(52 x 75) ASTM E1886-05/E1996-04 Wind Zone 4-Missile Level D TAS 201/202/203-94 Design Pressure: +70/-70 psf Large Missile Impact Rated Product Tested By: National Certified Testing Laboratories,Inc. Report No: NCTL-110-10728-1/110-10728-2/110-10728-3 Expiration Date: April 30,2019 Administrator's Signature: NATIONAL ACCREDITATION AND , MANAGEMENT INSTITUTE, INC. 4794-George Washington Memorial Highway Hayes,VA 23072 Tel: (804)684-5124 Fax: (804)684-5122 i I I � L. Roberto Lomas P.E. 13'0129.27-COMP 233 W.Main St Danville,VA 24541 434-688-0609 rllomas@lrlomaspe.com June 8;2015 Ref: N.O.A. 13-0129.27 Manufacturer:.E.I. DuPont De Nemours &Co.,.Inc. DuPont P&IP Chestnut Run Plaza, 712/161,P.O.,Box 80712 Wilmington,DE 19880 Product: DuPont Butacite@ PVB Interlayer j To Whom It'May Concern: This is to certify that I have reviewed all documentation for the above mentioned N.O.A. After my review and to the best of my Imowledge, I found that the products in the,N.O.A. listed.above comply with the requirements of the Florida Building Code 5t"Edition,(2014). I , Please note that I don't have nor will acquire a financial interesfin any;company'manufacturing,or. distributing the product(s)for which the reports are being issued. i ' Also,.I don't have nor will acquire a financial interest in any other entity involved in the approval process of the listed product(s). Sincerely, IJ 111i �� gR• �b ii ' �� • TAT OF ORID •c� i� ONAL�F`��� Luis R. Lomas P.E. FL No.: 62514 ' I 1-of 1 I REVISIONS REV DESCRIPTION DATE APPROVED D REVISED GLAZING DETAILS 10/30/15. R.L: NOTES: 15. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 REQUIREMENTS OF THE FLORIDA BUILDING CODE INCLUDING THE HVHZ. 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY INSTALLATION DETAILS. TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 16. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED 17. ALL FASTENERS TO BE CORROSION RESISTANT. INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO 18. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: FASTENED TO MASONRY. CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH B: CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH f'm=2,000PSI MINIMUM. 6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MIST BE SEPARATED WITH APPROVED D. METAL STRUCTURE: STEEL 18CA (.048") FY=33KSI/FU=52KSI OR COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE 15 THE RESPONSIBILITY OF ALUMINUM 6063—T5 FU=30KSI 1/8" THICK MINIMUM THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 8. FOR FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED RIGID PVC. 12. UNITS MUST BE GLAZED PER ASTM E1300-04, SEE SHEET 2 FOR GLASS DETAILS. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS NjZRE-ULR D FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS, 14. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE //10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT' INTO _ SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.. _•_' . --ri,-., SIGNED: vozr2or5"o;; - -_ - - - - - VINYL--WINDOW RVINEcHNOLL�-OGIEES; INC.-2400 NC.- ````J`S R ILta PADUCAH, KY 42002 `v,•�\GENSFgif' TABLE OF CONTENTS SHORELINE DOUBLE HUNG WINDOW 5100 _*• AQ0.6251 SHEET NO. DESCRIPTION 52" X 75" NOTES TAT OF AV 4�1 1 NATES DRAWN: DWO NO. REV //�O��s 2 ELEVATION & GLAZING DETAIL R.L.E DATE OS SOOE206 D � QNA;`��\\\` . 3 — 8 INSTALLATION DETAILS NTS 07/25/07 1 OF 8 ' REVISIONS REV DESCRIPTION DATE APPROVED -D REVISED GLAZING DETAILS 10/30/15 R.L. - 52" MAX FRAME WIDTH 6" MAX ---{ 13 1/2 6" MAX - + IMAX O.C. 6" MAX J / 12 3/4" MAX O.C. / — 7/8" 75" �— MAX 1/8" ANN FRAME —�— HEIGHT — — .090" DUPONT BUTACITE PVB / 1/8" ANN 1/8" ANN SPACER I X / EXTERIOR 1 INTERIOR 5/8' BITE L- DOYJ 995 n �6" MAX SEALANT GLAZING DETAIL - -SL5100iDH5275 - EXTERIOR VIEW - - -- DESIGN PRESSURE RATING _ IMPACT RATING_ t70.OPSF LARGE MISSILE IMPACT SIGNED: 11/02/2015 — _— —_ _— — ---- --_ -- -- =---VINYL—WINDOW-N0RV NECOBBODOR VEE—S-, INC. - - \\)\01111 11////, - - PADUCAH, KY 42002 `v•'\GEAf y-- cp SHORELINE. DOUBLE HUNG WINDOW 5100 ;*• 05OF 52" X 75"ELEVATION & GLAZING DETAIL DRAWN: DWG N0. REV %�'PFs'OCORIOP DATE 08-00206 D j7ONA 1 SCALE NTS 07/25/07 2 OF 8 1/2" MIN. REVISIONS EDGE DISTANCE REV DESCRIPTION Dare APPROVED WOOD FRAMING - - D:. REVISED GLAZING DETAILS 10/30/15 R.L: OR 2X BUCK BY OTHERS ,>,A 1 1/4" MIN. EMBEDMENT u BACKER ROD 1/4" MAX. & APPROVED SHIM SPACE SEALANT 1 1/4" MIN. 1/4" MAX. EMBEDMENT r SHIM SPACE X10 WOOD SCREW I INTERIOR O O 1/2" MIN. 0 EDGE DISTANCE nu jl 10 WOOD SCREW 0 p WOOD FRAMING m11v Q� 0 OR 2X BUCK INTERIOR BY OTHERS o EXTERIOR --7 - _ -v BACKER ROD i APPROVED r SEALANT EXTERIOR JAMB INSTALLATION DETAIL 'I WOOD FRAMING OR 2X BUCK INSTALLATION I (� SILL TO BE SET l O IN A BED OF ❑ APPROVED SEALANT BACKER ROD a ` & APPROVED 1/4" MAX. SEALANT SHIM SPACE - -- S S _ NOTES.- I.- OTES:i.- INTERIOR AND EXTERIOR FINISHES,BY OTHERS, WOOD FRAMING NOTSHOWNFORCLARITY. OR 2X BUCK. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE BY OTHERS - DESIGNED IN ACCORDANCE WITH ASTM E2112 VERTICAL CROSS SECTION SIGNED: 11/02/2015 _WOOD FRAMING OR 2X BUCK INSTALLATION - - - - - --- - -- - - - —-- - - --- ----- -- —VI NYL=WIaooDOW lav N—TECH COBB OD�IVEES; INC:-- — ```\J\5 R�►Co* ' _-- PADUCAH, KY 42002 `v,•'\CENS+*•'�s�� SHORELINE DOUBLE HUNG WINDOW 5100 ?�c• 0, 51 *= INSTALLATION DETAILS DRAWN: DWO N0. REV �'OQS;�,[OR1.P SALE DATE 08 500206 D NTS 07/25/07 3 OF 8 REVISIONS 3/4" MIN REV DESCRIPTION DATE APPROVED EDGE DISTANCE 1/4" MAX. METAL SHIM SPACE STRUCTURE BY OTHERS 1= APPROVED I j SEALANT 1 4" MAX. FSHIM SPACE #10 SMS OR L— I INTERIOR SELF DRILLING SCREW0 3/4" MIN. ED � EDGE DISTANCE I �— ❑ C� #10 SMS OR pSISUII 0� O SELF DRILLING EXTERIOR I INTERIOR SCREWS o a, Q METAL BACKER ROD STRUCTURE & APPROVED EXTERIOR BY OTHERS I SEALANT I JAMB INSTALLATION DETAIL Q _ METAL STRUCTURE INSTALLATION SILL TO BE SET IN A BED OF ❑ APPROVED SEALANT BACKER ROD a & APPROVED SEALANT l 1/4" MAX. SHIM SPACE NOTES: METAL-----, ETAL 0--'- - _ 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, STRUCTURE I, NOT SHOWN FOR CLARITY. BY OTHERS 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION SIGNED: 11/0212015 - - --- - --= -- - _ - - - -_ = VINYL—WINDOW EHNOLO IES,-INC --.- _\\`\J\St�RiiLro q - 2400 vNCOBB PADUCAH, KY 42002 `r••��GENs �cpi' SHORELINE DOUBLE HUNG WINDOW 5100 *• 0,�6�5 *= 52" X 75" INSTALLATION DETAILS TATE OF DRAWN: DWG NO. REV ���� 'QCOR10Pa RSCALE NTS one 07/25/07 08-00206 24 D 0E 8 ,///sS��IItAl1�►��G\`\ 7R6-�IDINS2 1/2" MIN, Dnrf MRRbVEDEDG£ DiSTANGE REV bESCRtPr1'LREVISED GLAZING DETAILS10/30/15 R.U. CONCRETE/MASONRY BY OTHERS n ° 4` ° a 1 1/4" MIN. OPTIONAL 1X BUCK ' ° a ° EMBEDMENT 1 1/4" MIN. 1/4" MAX. SEE NOTES 3 - 7 °a 4 a EMBEDMENT SHIM SPACE SHEET 1 �J CONCRETE/MASONRY BY OTHERS BACKER ROD 1/4^ MAX. ov & APPROVED QST SHIM SPACE SEALANT OPTIONAL 1X BUCK r- SEE NOTES 3 - 7 ° v ° 3j16" TAPCON SHEET 1 INTERIOR U 3/16" TAPCON v E= EXTERIOR 2 1/2" o n C C] co INTERIOR EDGE q ' a 1UlWUg 4R DISTANCE I L — (I SACKER ROD EXTERIOR { & APPROVED SEALANT i JAMB INSTALLATION DETAIL SILL TO BE SEI' CONCRETE/MASONRY INSTALLATION BACKER ROD IN A BED OF R_APPROVED APPROVED SEALANT 1, INTER1ORANDEXTERIOR F7N7SHES,&YOFHERS, SEALANT 1/4" MAX. NOT SHOWN FOR CLARITY. OPTIONAL 1X BUCK SHIM SPACE 2. DESIGNED AND INAccoRoAm EWIT ASTMERSTOSE SEE NOTE 3 - 7 DESIONEDINACCORDANCEWITHASTME21f2 - - _ -SHEET I- 7. - xc'` CONCRETE/MASONRY SIGNED: 11/02/2015 BY OTHERS I VINYL WINDOW—T 6HNOLOG — INC,IE 4 J 2400 IRVIN COBE DRIVEN��J\ O�yzPADUCAH, KY 42002VERT(GAL CROSS SEGT(ON SHORELINE'DOUBLE HUNG WINDOW *' a ;52" X 75" `CONCRET&MASONRYINSTALLATION INSTALLATION DETAILSi�1„ TAT OF RRhWN: DWG ND. f!/ate+` ��QRR.L. 08-00206 "//S�ONAL��IN' ba�E NTS DATE 07/25/07 SI-T5 OF 8 lftltlEltttlj1� WOOD FRAMING 1/2" MIN, REVISIONS OR 2X BUCK EDGE DISTANCE REV DESCRIPTION DATE APPROVED BY OTHERS .. D REVISED GLAZING DETAILS 10/30/15 R.L. BACKER ROD 1 1/4" MIN. & APPROVED EMBEDMENT SEALANT j l 1/4" MAX. SHIM SPACE 1 1/4" MIN. 1/4" MAX. EMBEDMENT FSHIM SPACE �- #10 WOOD SCREW WOOD FRAMING INTERIOR O O OR 2X BUCK BY OTHERS #10 WOOD SCREW L 7 112- MIN. o EDGE DISTANCE INTERIOR T o o -- �� �4 Ultttlll'I iN % BACKER ROD & APPROVED EXTERIOR II SEALANT EXTERIOR JAMB INSTALLATION_DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION SILL TO BE SET 1 El IN ABED OF APPROVED SEALANT 1/4" MAX. SHIM SPACE NOTES: J � - 1:- INTERIOR AND EXTERIOR FINISHES,-BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE BACKER ROD DESIGNED IN ACCORDANCE WITH ASTM E2112 -&--APPROVED--. - - SEALANT WOOD FRAMING VERTICAL CROSS SECTION SIGNED: 11/02/2015 - —---OR-2X-BUCK WOOD-FRAMINGOR"2XBUCK-INSTALLATION- BY OTHERS - - - - -- ---VINYL-WINDOW TECHNOLOGIES; -INC-- 2400 IRVIN COBB DRIVE ��`��g R• LO PADUCAH, KY 42002 v•��GENS -9cp SHORELINE DOUBLE HUNG WINDOW 5100 ;*• 0,61251/� *= 52" X 75" �� INSTALLATION DETAILS ��0, TATE OF DRAWN: DWG NO. REV �'P••'PlOR10P• RAL0800 E NTS DATE 07/25/07 526 60E 8 ' REVISIONS METAL 3/4" MIN REV DESCRIPTION DATE APPgOVEO STRUCTURE EDGE DISTANCE BY OTHERS ' 1/4" MAX. APPROVED SHIM SPACE SEALANT 1/4" MAX. SHIM SPACE ' #10 SMS OR SELF DRILLING SCREW x/10 SMS OR INTERIOR SELF DRILLING I SCREWS 0 EXTERIOR 3/4" MIN. EDGE DISTANCE C� ' �� r a 411gri1f1 1111� r METAL O STRUCTURE o I INTERIOR BY OTHERS BACKER ROD EXTERIOR & APPROVED SEALANT fl SILL' TO BE SET JAMB INSTALLATION DETAIL = IN A BED OF METAL STRUCTURE INSTALLATION ❑�I APPROVED SEALANT ----�- 1/4" MAX. NOTES. -� SHIM SPACE 1. -INTERIOR AND EXTERIOR FINISHES,BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE BACKER ROD DESIGNED IN ACCORDANCE WITHASTM E2112 -_& APPROVED SEALANT VERTICAL CROSS SECTION METAL STRUCTUREMETAL STRUCTURE INSTALLATION SIGNED: 11/02/2015 _ -- BY OTHERS - - -----` -- -- - - - - _= _ - -= - - -- --- --VINYL-WI4DoOWaIN-TECHNOLOGEES-,-ING— - - \J`S�R 14Lo ' PADUCAH, KY 42002 `r,•�\GENSF9s�� SHORELINE DOUBLE HUNG WINDOW 5100 *• 0, 251 52" X 7D —,o INSTALLATION DETAILS LDRAIWIN: kEV ��DATE 07/25/07 08-00"-76OF 8 D 2 1/2" MIN. REVISIONS CONCRETE/MASONRY EDGE DISTANCE REV DESCRIPTION DATE APPROVED BY OTHERS D: REVISED GLAZING DETAILS 10/30/15 R.C. a 1 1/4" MIN. OPTIONAL 1X BUCK �- ° ° °a ° EMBEDMENT 1 1/4" MIN. 1/4" MAX. SEE NOTES 3 - 7 EMBEDMENT SHIM SPACE SHEET 1 CONCRETE/MASONRY BY OTHERS OPTIONAL IX BUCK v 1/4" MAX. SEE NOTES 3 - 7 , BACKER ROD ��a� SHIM SPACE SHEET i & APPROVED „ SEALANT r ❑ a 3/16" TAPCON 3/16" TAPCON Q Q • INTERIOR v „ U ICJ O �i,aw�,lt�n EXTERIOR 2 1/2" MIN. ao EDGE DISTANCE ov • „ USMntty!tin I I INTERIOR BACKER ROD EXTERIOR & APPROVED SEALANT I i JAMB INSTALLATION DETAIL Q_ CONCRETE&IASONRY INSTAL I LATION SILL TO BE SET O IN A BED OF APPROVED SEALANT NOTES: - 1, INTERIOR AND EXTERIOR FINISHES,BY OTHERS, BACKER ROD 1/4" MAX. NOTSHOWNFOR CLARITY. & APPROVED SHIM SPACE 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED 1N ACCORDANCE WITH ASTM E2112 — - SEALANT,_ - —I - - „ SIGNED: 11/02/2015 OPTIONAL IX3BUC� a a. ° a „ ° d ° - — -- - - - -_ VINYL=WI4000 RV NECOBBODOR VEES,-INC.- — ``\\J\S 1:0 � / SHEET tSEE ° ° n PADUCAH, KY 42002 `r,•4�GENSF9cP VERTICAL CROSS SECTION SHORELINE DOUBLE HUNG WINDOW 5100 *• 0,-q 1 * CONCRETE/MASONRY CONCRETE/MASONRYINSTALLATION INSTALLATION X 75" a= BY OTHERS TION DETAILS ��D; STATE OF ZZ \ oRAWN: owc NO. HEV �c` [ORIOQ; SCALE NTS DATE 07/25/07 08-0020 86OF 8 D