HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2
f I,a
IZ., "� +�. � •,ilk 4�� ��'���
-" - _ --- - BQS Home - Log In User Registration Hot Topics - Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links Search
Business
Product Professional \ USER:PubllApproval
Product Approval Menu>Product or Application Search>Application Lis[>Application Detail
FL t FL2569-R10
" Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer Soprema,Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville,NON-US 00000
(819)478-2400 Ext 3327
memathieu@sop rema.ca
Authorized Signature Marc-Etienne Mathieu
memathieu@soprema.ca
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville,NON-US 00000 I
(819)478-2400 Ext3327
memathieu@soprema.ca
Quality Assurance Representative Jean-Francois Cote,Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
i
Category Roofing
Subcategory Un derla yments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J. M. Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/16/2017
Validated By ]ohn W. Kriezevich,PE
," Validation Checklist-Hardcopy Received
i
Certificate of Independence FL2569 R10 COI 2015 01 COI Nieminen.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2009
ASTM D6163 2000
ASTM D6164 2005
FM 4474 2004
FRSA/TRI April 2012(04-12) 2012
TAS 103 1995
TAS 110 2000
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?paraln=wGEVXQwtDgsKQFEnckB 10... 8/19/2015
Florida Building Code Online Page 2 of 2
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 06/29/2015
Date Validated 07/02/2015
Date Pending FBC Approval 07/09/2015
Date Approved 08/18/2015
SummarV of Products
FL# Model, Number or Description
Name
2569.1 Soprema Roof Self adhering roof underlayments
Underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL2569 R10 II 2015 06 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569-
Approved for use outside HVHZ:Yes R10.pdf I
Impact Resistant:N/A Verified By: Robert Nieminen,P.E. PE-59166
Design Pressure: +N/A/-90 Created by Independent Third Party:Yes
Other: 1.)Refer to ER Section 5 for Evaluation Reports
Limits of Use.2.)The design pressure FL2569 R10 AE 2015 06 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569-
noted herein pertains to underlayment R10.pdf
systems used beneath adhesive-set tile Created by Independent Third Party:Yes
systems. Refer to ER Section 5.6.4 for
details.
;Back Ne#
i
Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AAJEEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395."Pursuant to
section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
rvv;a�'.j;�.. C7
http://www.floridabuildin-.org/nr/pr app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB10... 8/19/201
1
EXTERIOR RESEARCH&DESIGN, LLC.
Certificate of Authorization#9503
353 CHRISTIAN STREET,UNIT#13
I-RINITY ERD OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Soprema,Inc. Evaluation Report S18010.06.09-118
1640 rue Haggerty FL2569-R10
Drummondville,Quebec J2C 5P8 Date of Issuance:06/15/2009
Canada Revision 8:06/29/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by,the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Robert J.M.Nieminen•P.E. The facsimile seal appearing was authorized by Robert Nieminen,
':r•���=C R t`.r ;•� P.E.on 05/29/2015.This does not serve as an electronically signed
Florida Registration No.59166,Florida DCA ANE19831 document.Signed,sealed hardcopies have been transmitted to the
Product Approval Administratorandtothe named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturingilor distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
I
1 i
INERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following
sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Resistance FM 4474 2004
1507.2.4,1507.2.8,1507.2.9.2, Physical Properties ASTM D1970 2009
1507.4.5.1,1507.5.3,1507.7"3
1507.11.2 Physical Properties ASTM D6163 2000
1507.11.2 Physical Properties ASTM D6164 2005
1523.6.5.2.1 Physical Properties TAS 103 1995
TAS 110 Accelerated Weathering TAS 110 2000
1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012
3. REFERENCES:
Knibt Examination Reference Date
ERD(TST6049) ASTM D1970/TAS 110 2968.05.04-2 05/14/2004
ERD(TST6049) Physical Properties 2757.02.05 02/03/2005
ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) Wind Resistance 2779"11.05-R1 04/18/2007
ERD(TST6049) TAS 103/TAS 110 57120.11.07-2 11/02/2007
ERD(TST6049) ASTM D1970/TAS 110 513190.02.09-R1 04/01/2010
ERD(TST6049) ASTM D1970/TAS 110 531370.03.10-1-R1 04/07/2010
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.10-R1 09/09/2010
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.09-R2 10/05/2010
ERD(TST6049) ASTM D1970 S37210.11.11 11/09/2011
ERD(TST6049) ASTM D1970 540540.02.13-1 02/19/2013
ERD(TST6049) Physical Properties/Tensile Adhesion 543530.02.14-1 02/21/2014
ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Physical Properties/Accelerated Weathering SOPC-SC8520.14 04/17/2015
M-D(CER1592) HVHZ Compliance 09-1005.02 11/04/2010
M-D(CER1592) HVHZ Compliance 13-0530.02 11/27/2014
ICC-ES(EVL2396) 2012,2009 and 2006 IBC Compliance ESR-1524 10/01/2014
PRI(TST5878) Physical Properties SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 05/29/2015
UL,LLC(QUA9625) Quality Control Service Confirmation Exp.10/16/2017
4. PRODUCT DESCRIPTION:
4.1 Lastobond TU HT is a self-adhering,non-woven polyester fabric surfaced,SBS modified bitumen roof underlayment.
4.2 Lastobond Shield is a self-adhering,woven polyethylene surfaced,SBS modified bitumen roof underlayment available
in two widths;36 and 45 inch.
4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment;available in 3.3 ft x 65 ft rolls.
4.4 Lastobond Shield HT is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof
underlayment.
4-5 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment
available in two widths;36 and 45 inch.
4.6 Lastobond Pro HT-S is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof
underlayment.
4.7 Lastobond 195 is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment.
Exterior Research and Design,U.C. Evaluation Report 518010.06.09-R8
Certificate ofAuthorfzatfon#9503 FL2569-R10
Revision 8:06/29/2015
Page 2 of 6
4.8 Lastobond is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment.
4.9 Lastobond Eco is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment.
n
4.10 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced, SBS modified bitumen roof
underlayment.
4.11 RESISTO LB1236 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,
with a 36-inch sheet width.
4.12 PrimeSource Grip-Rite Eave &Valley Protector is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified
bitumen roof underlayment,with a 36-inch sheet width.
4.13 RESISTO LB1244 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,
with a 44-inch sheet width.
4.14 Colphene FR GR is a self-adhering,fiberglass reinforced,granule-surfaced,SBS modified bitumen roof underlayment.
4.15 Unilay (e) is a mechanically attached, polyester reinforced, granule-surfaced, SBS modified bitumen roof
underlayment.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ. 9
5.3 Fire Classification is not part of this report;refer to current Approved Roofing Materials Directory for fire ratings of this
product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed,a request may be made to the AHJ for approval based on this evaluation
combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop the underlayments are follows:
TABLE 1:ROOF COVER OPTIONS
Asphalt Wood Shakes&
Underlayment Shingles Nail-On Tile Foam-On Tile Metal Shingles State
Lastobond TU HT Yes Yes Yes Yes Yes Yes
See 5.5.1
Lastobond Shield/Pro HT-N/ yes No No No Yes Yes
RESISTO SA SMOOTH PLY 40
Lastobond Shield HT/Pro HT-5 Yes No No Yes Yes Yes
Lastobond/Lastobond 195 Yes No No No Yes Yes
Lastobond ECO /RESI5T0 L81236,
p .ate Eave&Valley Protecto Yes No No No Yes Yes
€SISTO LB2244
11"M—Smooth Seal HT Yes No N p Yes Yes Yes
Colphene FR GR Yes Yes Y�s
See .5.1 No Yes Yes
Yes Y
Unilay(e) Yes
Batten Only See�..5.1 No No No
5.5.1 "Foam-On Tile is limited to use of the following adhesives unless to site adhesion/ long term aging data from an
accredited testing laboratory is provided.
Underlayment Adhesive(s)
Lastobond TU HT 31A 2-Component Foam Roof Tile Adhesive AH-160(FL6332)or Dow Chemical TileBond"Roof
Tile Adhesive(FL717)
Colphene FR GR 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
Unilay(e) 3M 2-Component Foam Roof Tile Adhesive AH460(FL6332)
i
Exterior Research and Design,LLC. Evaluation Report S18010.06.09-118
Certificate of Authorization#.+9503 FL2569-R10
Revision 8:06/29/2015
�. Page 3 of 6
TRIN 1Y ERD
4.8 Lastobond is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment.
4.9 Lastobond Eco is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment.
4.10 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced, SBS modified bitumen roof
underlayment.
4.11 RESISTO LB1236 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,
with a 36-inch sheet width.
4.12 PrimeSource Grip-Rite Eave &Valley Protector is a self-adhering, glass-mat reinforced,sand-surfaced, SBS modified
bitumen roof underlayment,with a 36-inch sheet width.
4.13 RESISTO LB1244 is a self-adhering, glass-mat reinforced, sand-surfaced, SB5 modified bitumen roof underlayment,
with a 44-inch sheet width.
4.14 Colphene FR GR is a self-adhering,fiberglass reinforced,granule-surfaced,SBS modified bitumen roof underlayment.
4.15 Unilay (e) is a mechanically attached, polyester reinforced, granule-surfaced, SBS modified bitumen roof
underlayment.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this report;refer to current Approved Roofing Materials Directory for fire ratings of this
product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed,a request may be made to the AHJ for approval based on this evaluation
combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop the underlayments are follows:
TABLE 1:-ROOF COVEROPTIONS
Underlayment Asphalt Nail-On Tile Foam-On Tile Metal Wood Shakes& Slate
Shingles Shingles
Lastobond TU HT Yes Yes Yes Yes Yes Yes
See 5.5.1
Lastobond Shield/Pro HT-N/ Yes No No No Yes Yes
RESISTO SA SMOOTH PLY 40
Lastobond Shield HT/Pro HT-S Yes No No Yes Yes Yes
Lastobond/Lastobond 195 Yes No No 'No Yes Yes
Lastobond ECO /RESISTO LB1236,
Grip-Rite Eave&Valley Protector/ Yes No No No Yes Yes
RESISTO LB1244
Lastobond Smooth Seal HT Yes No No 'Yes Yes Yes
Colphene FR GR Yes Yes Yes No Yes Yes
See 5.5.1
Yes Yes
Unilay(e) Yes No No No
Batten Only See 5.5.1
5.5.1 "Foam-On Tile" is limited to use of the following adhesives unless tensile adhesion / long term aging data from an
accredited testing laboratory is provided.
Underlayment Adhesive(s)
Lastobond TU HT 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)or Dow Chemical TileBond—Roof
Tile Adhesive(FL717)
Colphene FR GR 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
Unilay(e) 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
Exterior Research and Design,LLC. Evaluation Report 518010.06.09-118
Certificate of Authorization#9503 FL2569-R10
Revision 8:06/29/2015
Page 3 of 6
TRINITY; R
5.6 Allowable substrates are noted below:
5.6.1 Direct-Bond to Deck:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond Pro HT-S
applied to:
Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow*Pine; ASTM•D41 primed
Southern Yellow Pine;ASTM D41 primed structural concrete.
Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave &Valley Protector,
RESISTO LB1244 or Lastobond Smooth Seat HT applied to:
➢ Plywood;ASTM D41 primed plywood;OSB;ASTM D41 primed OSB;ASTM D41 primed structural concrete.
Colphene FR GR applied to:
> Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete.
Note:
i While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends priming with
Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours.
Y Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the
self-adhering underlayment.
5.6.2 Bond-to-Insulation:
Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Lastobond Pro HT-S or Colphene FR GR applied to:
9 DensDeck DuraGuard;DensDeck Prime;SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile
systems,insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FM 4474,Appendix D or TAS 114,Appendix J.
5.6.3 Bond to Mechanically Attached Base Layer:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-5 or
Colphene FR GR applied to:
9 ASTM D226,Type I or 11 felt;Sopra-G;Modified Sopra-G.
For installations under mechanically attached prepared roof coverings, base layer shall!be attached per minimum
codified requirements. For installations under foam-on the systems,base layer shall be attached in accordance with
FRSA/TRI April 2012(04-12).
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where the underlayment
forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for
determination of design wind pressures.
5.6.4.1 Maximum Design Pressure=-45.0 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AH1.
Primer: (Optional)Elastocol Stick or Elastocol 600c
Underlayment: Colphene FR GR,self-adhered.
5.6.4.2 Maximum Design Pressure=-67.5 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: Elastocol 600c
Underlayment: Colphene FR GR,self-adhered.
I
Exterior Research and Design,LLC. Evaluation Report 518010.06.09-118
Certificate of Authorization 49503 FL2569-R10
Revision 8:06/29/2015
Page 4 of 6
i
r�
TRNFY i E A
5.6.4.3 Maximum Design Pressure=-60.0 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps (FBC
1517.5.2)spaced 6-inch o.c.at the 4-inch laps and 6-inch o.c.in three,equally spaced rows in the
center of the sheet.
Underlayment: Colphene FR GR,self-adhered
5.6.4.4 Maximum Design Pressure=-90.0 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Underlayment: Unilay(e)mechanically attached with Soprafix Polymer Batten Bar(PBB)or Soprafix Metal Batten
Bar (MBB) with Soprema #15-EL fasteners spaced 6-inch o.c. within the 5-inch wide, self-
adhering side laps. End laps are 6-inch wide and sealed using either heat-welding or hot-air
welding techniques.
5.7 Exposure Limitations:
5.7.1 Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond, Lastobond 195,Lastobond Eco,
Lastabond Smooth Seal HT, RESISTO LB1236, Grip-Rite Eave&Valley Protector or RESISTO LB1244 shall not be left
exposed for longer than 30-days after installation.
5.7.2 Lastobond Shield HT or Lastobond Pro HT-S shall not be left exposed for longer than 90-days after installation.
5.7.3 Lastobond TU HT or Colphene FR GR or Unilay(e)shall not be left exposed for longer than 180-days after installation.
6. INSTALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate with Elastocol Stick or Elastocol 600c(if applicable).
6.3 Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY'40, Lastobond Shield HT,
Lastobond Pro HT-S,Lastobond Lastobond 195,Lastobond Eco,Lastobond Smooth Seal HT,RESISTO LB1236,Grip-
Rite Eave&Valley Protector,RESISTO LB1244 or Colphene FR GR: ,
.6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the
type of prepared roof covering to be installed.
6.3.2 Non-Tile Applications:
While priming is optional,Soprema recommends priming with Elastocol.Stick or Elastocol 600c if the final roof cover
is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release
film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane
tight. Firmly roll the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-inches and
staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed using
either heat-welding or hot air welding techniques.
When installing at slopes above 8:12,Soprema recommends back-nailing in the overlap area at the top of the sheet
at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over
valley or ridge.Drape and press sheet into place,working from the center of the valley or ridge in each direction. For
valleys,apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications(Lastobond TU HT or Colphene FR GR only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 he''rein, using the instructions
noted above as a guideline.
For Colphene FR GR in foam-on tile applications, reference is made to Section 5.6.4.herein for wind resistance
limitations.
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment.
i
i
Exterior Research and Design,I.I.C. Evaluation Report 518010.06.09-R8
Certificate of Authorization#9503 FL2569-R10
Revision 8:06/29/2015
Page 5 of 6
/ ^
|
� �^�_~
\ � !
TRINI@ Y���^�,����
� 6.4 Unilay(e):� �
6�.1
Reference bmade moTable 1herein and FRSAVTR April 2012(04-12)Installation Manual(if appKcable).
Apply sheet parallel u,the roof edge and,starting at the eave with the selvedge-edge upslope,mechanicallyottach
the 5-inch wide selvedge-edge to the wood deck with nails and tin caps or round cap-nails spaced 36-inch o.c. Apply
the second course in a water-shedding manner with self-adhering side-laps. Vigorous hand or motorized roller
pressure is applied to the self-adhering laps to ensure a watertight application. '
Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over-
granule end-bpsshaUbesee|edudngeitherheat+me/dingo,hotairwe|dinXtezhniques
. |
Tl|n (if applicable) shall be loaded and staged in e manner that prevents tile slippage and/or damage to the
undenaymemt '
`
6.4.2 /
Reference ismade»oFRSA/TR April ZO1a(0 -12)Installation Manual and Table 1henein �
' /
Apply sheet parallel to the roof edge and,starting at the eavevith the selvedge'-'edgeui�islopemechanically attach
the 5-inch wide selvedge-edge to the wood dpck5opcafiu Polymer Batten Bar(pB8) . � /� Metal�{ 8a �n Bar
(Kxea)vv�bSoprema#15'[Lfa�enenspaced G'incho.c Apply the second cou�eino �te' heddingnnannerwith
self-adhering side-laps. Vigorous hand or motorized roller pressure is applied to' the self-adhering laps to ensure a
watertight application. ,
Vertical seams should be6-inchesand staggered not less than l~ft from vertical seams in thecourse below. All over-
granule end-iapsshaUbesea/edosingeitherheat-me|din0o,hotai,we)d|ngtechoiques. .
Tile shall beloaded and staged inamanner that prevents tile slippage and/or dn damage to |
7' BUILDING PERMIT REQUIREMENTS: /
Asrequired bythe Building Official orAuthority HavinuJurisdkctioninnrdertoprmedyam|uatetheinsta|lationofthispmduct.
g' MANUFACTURING PLANTS: '
Contact the manufacturer urthe named CIA entity for information on plants covered under Rule G113QA requirements.
1
9. Quxum/ASSURANCE ENTITY:
UL,LLC—QUA90IS/(314)S78-34O6 kchanoellor@ca.u|.com '
-END mFEVALUATION REPORT' '
�
,
' |
|
.
"
o
�
/
{ �
/
Exterior Research and Design,uc
Report S18010.06.09-n
Certificate of Authorization m�m /
| FL2569-Ruo
| |
Revision 8:06/29/201S
|
Page ovma
| .
�
Florida Building Code Online Page 1 of 2
BCIS Home I Log In User Registration i Hot Topics Submit Surcharge Stats&Facts Publications FBc Staff p BCIS Site Map Links Search
b
a
Product Approval
a - USER:Public User G'
d.. v
i
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL10124-1119
Application Type Revision
Code Version 2014
i
Application Status Approved
Comments
Archived ❑
i
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parisppany,NJ 07054
(800)766-3411
mstieh@gaf.com
i
Authorized Signature Robert Nieminen
lindareith@trinityerd.com
Technical Representative Beth McSorley(current)
Address/Phone/Email 1 Campus Drive
Parsippany,NJ 07054
(973)872-4421
bmcsorley@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Li Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 03/03/2018
Validated By John W. Knezevich,PE
W Validation Checklist-Hardcopy',Receivedl
ii
Certificate of Independence FL10124 R19 COI 2016'01 COI Nieminemocif
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2009
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
i
TAS 107 1995
i
Equivalence of Product Standards
i' Certified By
Sections from the Code
h-tp://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquracBeVCbdMQ... 8/1/2017
Florida Building Code Online Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 08/26/2016
Date Validated 08/26/2016
Date Pending FBC Approval 08/30/2016
Date Approved 10/13/2016
Summary of Products
FL# Model,Number or Name Description
10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab,laminated,5-tab and hip/ridge
asphalt shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL10124 R19 II 2016 08 FINAL ER GAF Asphalt
Approved for use outside HVHZ:Yes Shingles_ FL10124-R19.pdf
Impact Resistant:N/A Verified By: Robert Nieminen PE-59166
Design Pressure: N/A Created by Independent Third Party:Yes
Other: Refer to ER,Section 5. Evaluation Reports
FL10124 R19 AE 2016 08 FINAL ER GAF Asphalt
Shingles FL10124-R19.pdf
Created by Independent Third Party:Yes
Back FNett
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please codtact 850.487.1395.'Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If
they have one.The emaits provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
® �
i�
i
Credit Card
Safe
http://www.floridabuilding.org/Dr/pr app_dtl.aspx?param=wGEVXQwtDquracBeVCbdMQ... 8/1/2017
EXTERIOR RESEARCH&DESIGN;LLC.
Certificate of Authorization#9503
< ®� ��1 �/ C® 353 CHRISTIAN STREET,UNIT#13
T�� I .I ERD OXFORD,CT 06478
i.. PHONE-,:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
GAF Evaluation Report 01506.01.08-1121
1 Campus Drive FL10124-1119
Parsippany, NJ 07054 Date of Issuance:01/03/2008
Revision 21:08/26/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials:in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described:herein have been evaluated for compliance with .the 5`h Edition (20141 Florida Building Code
sections noted herein.
DESCRIPTION: GAF Asphalt Roof Shingles
i
LABELING: Labeling shall be. in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named p'roduct(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that,relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors.and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by: .utntq,.
RobertJ:M.Nieminen,P.E. '4FS�t `���� The facsimile seal appearing was authorized by Robert Nieminen,
�_i�,•a n�!!lsps P.E.on 08/26/2016.This does not serve as an electronically signed
Florida Registration No.59166,Florida DCA ANE1983 document.Signed,sealed hardcopies have been transmitted to the
Product Approval Administratorand to the named client
CERTIFICATION Or INDEPENDENCE:
1. Trinity)ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates. i
2. Trinity I.ERD isnot owned,operated or controlled.by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports:are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. .This is a building code evaluation. Neither TrinityI ERD nor Robert Nieminen, P.E. are,in any way, the.Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was.used for permitting or design guidance unless retained
specifically for that purpose.
i
` TRINITY IERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category:. Asphalt Shingles
Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the
following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in
accordance with the following Standards. Compliance is subject to the Installation'Requirements and Limitations/
Conditions of Use set forth herein.
2. STANDARDS:
Section Prope Standard Year
1507.2.4,R905.2.3 Physical Properties ASTM D1970 2009
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009
1507.2.7.1,:R905.2.6.1 Wind Resistance ASTM D3161 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008
1507.2.7.1,R905.2.6.1 Wind Resistance TAS 107 1995
3. REFERENCES:
Enti Examination Reference Date
GAF(PDM 1915). Letter of Equivalency Seal-A-Ridge Impact Resistant IR 01/13/2012
PRI(TST 5878) Physical Properties GAF-025-02-01 03/27/2002
PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004
PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005
PRI(TST 5878) Physical Properties GAF-324-02-01 12/01/2011
PRI(TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013
UL(TST 1740) ASTM D3462 93NK6295 11/29/1993
UL(TST 1740) ASTM D3462 99NK43835 01/12/2000
UL(TST 1740) TAS 107 94NK9632 03/29/2000
UL(TST 1740) ASTM D3462 01NK06632 02/02/2001
UL(TST 1740) ASTM D3161,TAS 107 OINK9226 05/21/2001
UL(TST 1740) ASTM D3161 01NK37122 12/18/2001
UL(TST 1740) ASTM D3462 01NK37122 12/19/2001
UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002
UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002
UL(TST 1740) ASTM D3161 03CA5367 03/11/2003
UL(TST 1740) ASTM D3462 03NK26444 70/17/2003
UL_(TST 1740) ASTM D3462 04NK13850 06/07/2004
UL(TST 1740) ASTM D3161 04NK13850 06/23/2004
UL(TST 1740) ASTM D3161 04NK30546 03/10/2005
UL(TST 1740) ASTM D3462 04NK22009 05/06/2005
UL(TST 1740) ASTM D3161 04NK22009 05/09/2005
UL(TST 1740) ASTM D3462 05NK27924 02/10/2006
UL(TST 1740) ASTM D3161 OSNK27924 02/11/2006
VL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006
UL(TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006
UL(TST 1740) ASTM D3161,D3462 061CA35251 10/18/2006
UL(TST 1740) ASTM D3462 06CA31603 12/01/2006
UL(TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006
UL(TST 1740) ASTM D3161 07NK05228 03/13/2007
UL(TST 1740) ASTM D3161 06CA31611 04/04/2007
UL(TST 1740) ASTM D3161 06CA61148 04/09/2007
UL(TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007
UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 03/13/2008
UL(TST 1740) ASTM D3161,D3462 07CA55908 04/01/2008
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R21
Certificate ofAutharizution#9503 FL10124-1119
Revision 21:-08/26/2016
Page 2 of 6
Enti Examination Reference Date
UL(TST.1740) ASTM D3161,.D3462 09CA10592 03/26/2009
UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009
UL(TST.1740) ASTM D3161,13715%133462 09CA27281 08/27/2009
UL(TST 1740) ASTM D3161,D7158,D3462 IOCA35554 03/05/2010
UL(TST 1740) ASTM D3161,D7158,D3462 IOCA13686 05/15/2010
UL(TST 1740) ASTM D3462 IOCA07264 05/27/2010
UL(TST 1740) ASTM D3462 IOCA11953 10/29/2010
UL(TST 1740) ASTM D3161,D7158,D3462 1ONK11951 10/30/2010
UL(TST.1740) ASTM D3161,D7158,D3462 10NK12070 11/04/2010
UL(TST:1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 10CA53934 03/31/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/2011
UL(TST1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011
UL,LLC.(TST9628) ASTM D3462 12CA34891 10/12/2012
UL,LLC:(TST9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013
UL,LLC.-(TST9628) ASTM D3161 12CA38083 02/26/2013
UL,LLC.(TST 9628) ASTM D3161 13CA32332 06/18/2013
UL,LLC.(TST 9628) ASTM D3161 13CA37934 08/02/2013
UL,LLC.(TST9628) ASTM D3161,D7158,D3462 4786875675 07/17/2015'
UL,LLC.(TST9G28) ASTM D3161,D715B,D3462 4787434542 05/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mobile,AL 12/28/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Myerstown,PA 02/23/2016
UL,LLC.(QUA 9625) Quality Control inspection Report,R21,Tuscaloosa,,,AL 02/26/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Michigan Cty,IN 03/02/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report',R21,Shafter,CA 1 02/18/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report;R21,Savannah,6A 02%24/2016
UL,LLC.(QUA.9625) Quality Control Inspection Report,R21,Minneapolis,MN 02/09/2016
UL,LLC.(QUA.9625) Quality Control Inspection Report,R21,Mt.Vernon;IN 02/09/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Baltimore,MD 03/01/2016
UL,LLC:(QUA 9625) Quality Control inspection Report,R21,Tampa,FL 02/29/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Dallas,TX 02/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection.Report„R21,Ennis,TX 02/03/2016
UL,LLC.(QUA 9625) Quality Control Inspection.Report,R21,Fontana,CA 03/03/2016
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:.
4.1.1 Marquis" WeatherMax", Royal Sovereign® and Sentinel® are a fiberglass reinforced 3-tab asphalt roof
shingles.
4.1.2 Camelot°, Camelot® 11, Fortitude', Glenwood'"", Grand Canyon®, Grand,Sequoia®, Grand Sequoia° IR,
Grand Sequoia° ArmorShield'"", Monaco®, Sienna®, Timberline® American, Harvest°, Timberline"
ArmorShieldT'11,Timberline"Natural Shadow®,Timberline HD",Timberline"Cool Series°,Timberline Ultra
HD"and Woodland"are fiberglass reinforced,laminated asphalt roof shingles.
4.1.3 Slateline"is a fiberglass reinforced 5-tab asphalt roof shingle.
4.2 Hip&Ridge Shingles:
4.2.1 Seal-A-Ridge® Ridge Cap Shingles, Seal-A-Ridge® IR Impact-Resistant Ridge Cap Shingles, Seal-A-Ridge®
ArmorShieldT""Ridge Cap Shingles and TimbertexO Premium.Ridge Cap Shingles are;fiberglass reinforced,hip
and ridge asphalt roof shingles.
I
Exterior Research-and Design,LLC. Evaluation Report 01506.01.08-1121
Certificate of Authorization#9503 FL10124-1119
Revision 21:08/26/2016
Page 3 of 6
TRINITY ERD
4.3 Accessory Starter Strips:
4.3.1 Pro-Start°Eave/Rake Starter Strip Shingles and WeatherBlocker", Premium,Eave/Rake Starter Strip Shingles
are starter strips for asphalt roof shingles.
4.3.2 QuickStart® Peel & Stick Starter Roll is a is a mineral-surfaced, 'fiberglass-reinforced, self-adhering SBS
modified bitumen starter strip,nominal 9-inch x 33 ft roll,for use with asphalt shingles with exposure of 6-
inch or less..
4.3.3 StarterMatch` Sharter Strip Shingles are color-coordinated starter strips for use with Grand CanyonQ1 and
Grand Sequoia" series asphalt shingles. StarterMatch'" are installed as the second starter for Grand
Canyon®and Grand Sequoia"series installations.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity ERD nor,Robert Nieminen, P.E. are, in any way; the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance.unless retained specifically for that purpose:
I
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved .Roofing Materials
Directory for fire ratings of this product.
5.4 Wind Classification:
5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance.with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for
use in all wind zones up to V,,d= 150 mph (V,,it=.194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 The GAF hip & ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F,indicating the Shingles are acceptable for use in all wind zones up to
V.sd=150 mph(V it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3,and a
mean roof height of 60 feet or less. Calculations by a qualified design professional are required for
conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle..
5:5 All products in the roof assembly shall have quality assurance audit.in accordance.lwith the Florida Building
Code and F.A.C.Rule 61620-3.
6. INSTALLATION:
6.1. Underlayment:
6.1.1 Underlayment shall.be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be
Locally Approved per Rule 61620-3,per FBC Sections 1507.2.3; 1507.2.4 or R905.2.3.
6.2 Starter Shingles or Starter Strip:
6.2.1 Installation of Pro-Start Eave/Rake Starter Strip Shingles,-WeatherBlocker,Premium Eave/Rake Starter Strip
Shingles and QuickStart Peel.&Stick Starter Roll-shall comply with the GAF current published instructions.
6.3 Asphalt-Shingles:
6.3.1 Installation of asphalt shingles shall comply with the-manufacturer's current published instructions, using
minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following
exceptions:
➢ Camelot,Camelot II,Grand Canyon,Grand Sequoia, Grand Sequoia IR,Grand Sequoia ArmorShield,and
Woodland require minimum five(5)nails per shingle.
Slateline requires minimum six(6)nails.per shingle.
I
Exterior Research and Design,LLC. Evaluation Report 01506.01.08=1121
Certifimte.of Authorization#9503 FL10124-R19
Revision-21:08/26/2016
Page 4 of 6
I
l'RII ITY I ERD
63.:2 Fasteners shall be in accordance with manufacturer's published requirements, but not.less.than FBC 1507.2:6
or R905.2.5. Staples are not.permitted.
6.3.3 Where the roof slope exceeds 21 units vertical in.12 units horizontal, special methods of fastening are
required. Contact the shingle manufacturer for details.
6.4 Hip&Ridge Shingles:
6.4.1 Installation.of Seal-A-Ridge Ridge Cap Shingles,Seal-A-Ridge IR Impact-Resistant Ridge Cap Shingles and Seal-
A-Ridge ArmorShield, Ridge Cap Shingles shall comply with the manufacturer's current published instructions
with a minimum two(2)nails,minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter
beads of Henkel"Loctite PLS30 Roof&Flashing Sealant".
11.5 Sealant
(292 mmJ1" Sellante
(25 mm) (25(n Endui£d:6tanc6eit-6
Y I
Nail
Glavo
6 5V:7 518" Glouer
(168=194 mm)
II.
f.
12"
(305'mm}
6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply with the manufacturer's current
published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and
beads of Sonneborn NPI Gun Grade Polyurethane.Sealant or Henkel PL Roofing and Flashing Sealant..
1 t 6 , Seaulnl
ErclOd d'Onitchdibb
NOV
IAw b n
C� (3ti w rm i
.auer
20 rnm)
I
I
;;s�5 rru��9j
6.4.3 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905,2.5. Staples are not permitted.
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R21
Certificate of Authorization#9503 FL10124-R19
Revision 21:-08/26/2016
Page 5 of 6
'
TRINITY;ERD
7. LABELING:
7:1 Labeling.shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As.required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact,the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(847)664-3281
- END OF EVALUATION REPORT-
i
Exterior Research and Design,LLC. Evaluation,Report 01506.01.08-1121
Certificate of Authorization#9503 FL10124-1119
Revision 21:08/26/2016'
Page 6 of 6