Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval (2)
Florida Building Code Online A, BCIS Home Log In User Registration Hot Topics SubmitSurcharge Stats&Facts Publications FBC Staff BCIS Site Map Links Search bProduct Approval USER:Public User d r Product Aooroval Menu>Application Detail !X FL# DApproved Application Type s` Code Version Application Status z 'f Comments rArchived ❑ Product Manufacturer Soft-Lite LLC 7 Address/Phone/Email 10250 Philipp Parkway Streetsboro,OH 44241 (330)528-3400 Ext 1109 ti ker@soft-lite.com �s 'rr Authorized Signature Vivian Wright i rickw@rwbldgconsultants.com S # Technical Representative Address/Phone/Email t <4' "5' ��. Quality Assurance Representative Address/Phone/Email APO s Category Windows r Subcategory Horizontal Slider a. Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Lyndon F. Schmidt, P.E. Evaluation Report Florida License PE-43409 Quality Assurance Entity Farabaugh Engineering and Testing, Inc Quality Assurance Contract Expiration Date 12/31/2017 Validated By Ryan J. King, P.E. Validation Checklist- Hardcopy Received Certificate of IndependenceFL15781 R6 COI CERTIFICATE OF INDEPENDENCE.pdf Referenced Standard and Year(of Standard) Standard Year r AAMA/WDMA/CSA101/I.S.2/A440 2011 .,` AAMA/W DMA/CSA101/I.S.2/A440 2008 ASTM E1300 2004 &i t, ��.^ ASTM E1886 2005 ASTM E1996 2006 u ASTM E1996 2009 TAS 201, 202, 203 1994 https://Avww.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt3elSAInEOW9Taf7MFDxJQJWjAlVgb3pz`cpVaV3%26%2fNjA%3d%3d[2/3/2017 11:31:19 AM] Florida Building Code Online Equivalence of Product Standards Certified By AAM, y Sections from the Code Product Approval Method Method 1 Option D 1 Date Submitted 10/30/2015 Date Validated 10/30/2015 Date Pending FBC Approval 11/02/2015 Date Approved 12/15/2015 j - Summary of Products _ } - n FL# Model,Number or Name Description `w 15781.1 a. "Imperial LS DSI-12" Double Slider Extruded PVC Double Horizontal Sliding Window-(XX Window Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15781 R6 II INST 15781.1.12df Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15781.1 for Design Pressure Ratings, any FLiS781 R6 AE Eval 15781.1.2df additional use limitations, installation instructions and product Created by Independent Third Party: Yes s particulars. 15781.2 b. "Imperial LS TSI-12"Triple Slider Extruded PVC Triple Horizontal Sliding Window- (XOX Window Configuration) aT Limits of Use Installation Instructions 1� Approved for use in HVHZ: No X15781 R6 II INST 15781.2.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15781.2 for Design Pressure Ratings,any FL15781 R6 AE Eval 15781.2.pdf additional use limitations, installation Instructions and product Created by Independent Third Party: Yes particulars. — .......... – 15781.3 c. "5300 DSL53 (G5352)" Double Extruded PVC Double Horizontal Sliding Window- (XX I Slider Window Configuration) y+ – —- --...._........_.. ......_.... ......... LIMItS of Use Installation Instructions Approved for use in HVHZ: No FL15781 R6 II INST 15781.3.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15781.3 for Design Pressure Ratings,any FLIS781 R6 AE Eval 15781.3.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. i 15781.4 d. "5300 DSL53 (G5352)" Double Extruded PVC Double Horizontal Sliding Window- (XX Slider Window Configuration) �t Limits of Use Installation Instructions l ' ,�Z Approved for use in HVHZ: No FL15781 R6 II INST 15781.4.E Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports (- Other: See INST 15781.4 for Design Pressure Ratings,any FL15781 R6 AE Eval 15781.4.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. ' k b' 15781.5 e. "5400 SSL54(G5402)"Single Extruded PVC Single Horizontal Sliding Window-(OX or XO Slider Window Configuration) «x I Limits of Use — Installation Instructions Approved for use in HVHZ: No FL15781 R6 II INST 15781.5.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E.43409 https://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgt3e I SAInEO W9Taf7MFDxJQJ Wj AI Vgb3pzxp V aV3%2b%2fNjA%3d%3d[2/3/2017 11:31:19 AMI Florida Building Code Online % Impact Resistant: No ( Created by Independent Third Party: Yes I Design.Pressure: N/A Evaluation Reports Other: See INST 15781.5 for Design Pressure Ratings, any FL15781 R6 AE Eval 15781 5.pdff I additional use limitations, installation instructions and product Created by Independent Third Party: Yes I particulars. ._........_.... __._ 15781.6 'f "5400 SSL54(G5402)"Single Extruded PVC Single Horizontal Sliding Window- (OX or XO Slider Window Configuration) Limits of Use Installation Instructions Approved.for use in HVHZ:Yes FL15781 R6 II INST 15781.6 pdf tt Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 x° Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15781.6 for Design Pressure Ratings, any F 1 5781 R6 AE Eval 1 781.6.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes # particulars. .-__.. -._..._........ ; ....... _ ..._ ._ ..._..-__ ..... .... ........ _... _...._..__. _ _.. - ..._....-. 15781.7 i g. "5400 TSLF54"Triple Slider Extruded PVC Triple Horizontal Sliding Window- (XOX I Window Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FLIS781 R6 II INST 15781.7.]>df I Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 � 7 Impact Resistant: Yes Created by Independent Third Party: Yes ;k Design Pressure: N/A Evaluation Reports Other: See INST 15781.7 for Design Pressure Ratings, any FL15781 R6 AE Eval 15781.7.12df 4 s additional use limitations, installation instructions and product Created by Independent Third Party: Yes li � a� 1 particulars. -. 1 15781.8 h. "5400 TSLF54"Triple Slider Extruded PVC Triple Horizontal Sliding.Window- (XOX Window Configuration) Limits of Use Installation Instructions Approved for use in'HVHZ:Yes FL15781 R6 II INST_15781.8.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes # Design Pressure: N/A Evaluation Reports d t Other: See INST 15781.8 for Design Pressure Ratings, any FL15781 R6 AE Eval 15781.8.pdf additional use[imitations, installation instructions and product Created by Independent Third Party: Yes particulars. % ¢ •� Contact Llc:; 601 Blair Stone Road.Tallahassee FL 32399 Phone,850-487-1824 a� The State of Florida is an AA/EEO employer,Copyriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement:;Refund Statement s- Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395."Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal i address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click here. ] Product Approval Accepts: h „ r, Credit Card }� Safe ig 01 k , https://www.fl ori dabuiIding.org/pr/pr_app_dtl.aspx7param= GEVXQwtDgt3eISAInEOW9Taf7MFDxJQJWjA]Vgb3pzxpVaV3%2b%21NjA%3d%3 d[2/3/201711:31:19AM] R R W Building Consultants, Inc. W Consulting and Engineering Services for the Building Industry B PO. 230 Valrico.rt,33595 11I,anc813.659.9197 CFlaTida Board of Prokasioanal Cnrtina n.Crrlifieat¢or.:lWlenrizntion No.9813 l R578hi1 8 � i Product Sub Category Manufacturer Product Name Category Sok-Lite LLC "5400 SSL54(G5402)" Windows Horizontal Slider 10250 Philipp Parkway Single Slider Window Strootsboro,OH44241 "Impact" (3301528-3400 Scope: This is a Product Evaluation report issued by R W Building Consultants,Inc.and Lyndon F.Schmidt,P.E.(System ID#1988) for Soft-Lite LLC based on Rule Chapter No.61G20-3,Method 10 of the State of Florida Product Approval,Department of Business&Professional Regulation. RW Building Consultants and Lyndon F,Schmidt,P.E,do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations. 1.This product has been evaluated and is in compliance with the 5th Edition(2014)Florida Building Code(FBC)structural requirements including the"High Velocity Hurricane Zone". 2. Product anchors shall be as listed and spaced as shown on details,Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the'HVHZ"this product complies with Section 1626 of the Florida Building Code and does not require an impact resistant covering. 4. When used in areas outside of the"HVHZ-requiring wind Lome debris protection this product complies,with Section 1609.1.2 of the FBC and does not nuquire an impact resistant covering.This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM E1996 and Section 1609.1.2.2 of the FBC. 5. For 2x stud framing construction,anchor ng of t ase units shall be the same as that shown for 2x buck masonry construction. 6. Site conditions that deviate from the details of drawing FL 15781,6 require further engineefing analysis by a licensed engineer or s r 7. This product meets the water infiltration requirements for"HVHZ'. u1 in c m n ts,int u 1 to er ,s 1 e e lrements of FBC Section 2003. 9. See drawing FL-15781.6 for size and design pressure limitations. Supporting Documents: 1_ Test Report No. Test Standard Testing Laboratory Signed by TEL 03001201 TAS 201,202&203-94 Testing Evaluation Lab. William Shelton,P.E 2, Miami Dade NOA Materials Testing 13-0129.27 DuPont Butaeite°PVB Interlayer 14-0820.11 PVC Extrusions(Vision Extrusions Ltd.) 3. Drawing No. Prepared-by Sig ned&Seated by >,�° No.FL-15781.6 RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. 4. Calcuations Pretigred by Signed&Sealed by Anchoring RW Building Consultants,Inc(CA#9813) Lydon F.Schmidt P.E. ASTM E1300 Glass Load Lyndon F.Schmidt,P.E. 5. Quality Assurance Certificate of Participation issued by Forabaugh Engineering and Testing,Inc,certifying that Soft-Lite LLC is manufacturing products within a quality assurance program that complies with ISUIEC 17020 and Guide 53. Lyndon F.Schmidt.P.E. FL PE No.43409 Sheet 1 of 1 Liw a _ SN d E] Wmdowssyj Z Bri.nging quality to light. N M 00 0 10250 Philipp Parkway M n •;z Streetsboro.Ohio 44241a , x z d SEE CHART FOR FRAME SIZES —{ 0 ZU M m a` O w� m dad a �y oZ "5400 SSL54 (G5402)" i Single Slider Window w "IMPACT' 3 0 LL z GENERAL NOTESp O g J 1. This product has been evaluated and is in compliance with the 5th Edition(2014)Florida M W lal Building Code(FBC)structural requirements including the"High Velocity Hurricane Zone" v (HVHZ). w n c>> r 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to y 0 a base material shall be beyond wall dressing or stucco. a a / » 3. When used in the"HVHT'this product complies with Section 1626 of the Florida Building Code m��� and does not require an impact resistant covering. _ ' m 4. When used in areas outside of the"HVHT'requiring wind bome debris protection this product ti complies with Section 1609.1.2 of the FBC and does not require an impact resistant covering. This product meets missile level"a'and includes Wind Zone 4 as defined in ASTM E1996 and N rn Section 1609.1.2.2 of the FBC. W o z rn 5. For 2x stud framing construction,anchoring of these units shall be the same as that shown for a 2x buck masonry construction. o 6. Site conditions that deviate from the details of this drawing require further engineering analysis o S by a licensed engineer or registered architect. a °z �- 7. This product meets water infiltration requirements for"HVHZ". LU ..tea J N � 8. Aluminum components,including fasteners,shall meet the requirements of FBC Section 2003. :MAX GLASS. DESIGN PRESSURE S N o a DLO N z ❑ TABLE OF CONTENTS DIMENSION r mpE' POSRIVE NEGATIVE',: ❑ATF- 6119113 i SHEET# DESCRIPTION N.T.S. 1 Typical elevations,design pressures and general notes q4i** 875'x 57.312" GI +50.0 -50.0 mvc BY. JK m 2 Horizontal and vertical cross sections CHK.W. LFS 3 3 Buck and frame anchoring ORAWMG N❑.. 4 Bill of materials,components and glazing details NOTEduct is not to be installed over ff.height above d. FT._15781.6 n SHEET--1 -, 4 N R:\Oients\SaR-Ute Permanent\Flodda Product Approvals\FL-15781 Horizontal Sliders\C-Drawings\FL Current Drawings(2014)\FL-15781.5-6.dwg,2.6 0 0 0 0 O m CD 0, W m a P'O 7 O-_ 0 n �z � T � El COO N A - O � 0 Q C W Qn o 22 FA A � to O N W N N 0 (ll W to n � B O N z �4 ..� o V bf a I� m I A N A 0 o r N W a 00El- (3m 00 a S �� (� n- 3 O m.- � J m m� n � m y_ m a: x.0 O+ ❑ ❑ 6,01 0 :�Z rn Z Z m m w O n O x N A X c o X 70 C C - R � >c y • rn ❑ Q ❑ 0 .J. 1-1/4"MIN. �J �O O 1-1/4"MIN. EMB.)TYP.) EMB.)TYP.) ` NltN7.ry/ SCHIy� / No.43409 T £t $ PRODUCT: Doeumente Prepared By: I SOFT-UTE WINDOWS Lyndon F. Schmldt ��(� ... D�•�' IN I 21 \ P.E. No. 43409 (n o Z -472-17-15 UPDATE TO 5TH E0. 2014 FBC JK PART OR ASSEMBLY: BUILDING CONSULTANTS. INC. IDo to 1 12/15/14 REVISED DRAWING NO. JK P.O. Box 230. Valrico. FL 33595 A t NO DATE BY HORIZONTAL AND VERTICALRuf Phone No.: 813.659.9197 REVISIONS CROSS SECTIONS FBPE C.A. No. 9813 02013 R.W.a...a...CON9YLTANTy INC. `��lll II rr * 7' 6 0m,-02.•. •'14"MAX. % jj 1D O.C.(TYP.) w ro– m r (TYP.) S –� err/Ill 111�,�T` o n m z° (TYP.) 1.1 m i 0 Z U •I \ ,/�J n La s m C W "t m d o a I I —r I I III I g �o d a m I I III E Oz I I D III p� I I TYP, — III F 2X BUCK — o Ja: I I 2X III G 1X BUCK I I BUCK III DIRECT TO BUCK I I FRAME _ III D MASONRY r MASONRY I I MASONRY III z OPENING I I OPENING III 3 r ;,0d w M CC II En� W Y c 8. 1 I I III 1 1 'ol ZD w 00 it d q 00 BUCK ANCHORING FRAME ANCHORING 4 - U O Oz 2 2 W U n Z CONCRETE ANCHOR NOTES: 3 1.Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to mortarjoints. 1 a w 2.Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to maintain the min.edge distance to mortarjoints,additional concrete anchors Xi may be required to ensure the"MAX.ON CENTER"dimension are not exceeded. TYP.®HEAD AND SILL $ 3 Concrete anchor table F z ANCHOR ANCHOR MIN MIN CLEARANCE 'MtN CLEARANCE TYPE slit EMBEDMENT TO MASONRY TO ADJACENL' z EDGE ANCHOR +–z o B IT 4" DAELCOLE WALL N.T.S. � ULTRACONe 1/4" 1.1/4" 1" 4" DWG.BY.. JK m WOOD SCREW INSTALLATION NOTES: DHx.W. LFS 3 5 1.Maintain a minimum 5/8"edge distance.I"end distance,&I"o.c.spacing of DRAWING NO.: � wood screws to prevent the splitting of wood. FL-15781.6 0 SHEEP 3 OF 4 N K BILL OF MATERIALS ITEM 8 DESCRIPTION MATERIAL 3.77' `Q.�•:•�• .•'O!% A 1X BUCK SG>=0.55 WOOD _r is J_d ro B 2X BUCK SG>=0.55 WOOD , =U: �* * g_Z:i� C 1/4"MAX.SHIM SPACE 'N'•y Z Fi�O� o a D 1/4"X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL E MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI CONCRETE e. ` \ > 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 /VIII*p» `� Z o m o F #10 X 2-1/7'PPH SMS STEEL o Q G 1/4"X 3-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL W N'e g o o m o° X #8 X 3"PPH SMS W/RUBBER WASHER STEEL <i ❑ n a m M 0°.D. 1 MAIN FRAME' PVC r m d a 2 LOCK STILE' PVCo 3 PULL STILE' PVC E o z 0.06" �'+ c vi 4 MEETING STILE` PVC o �d 5 GLAZING BEAD* PVC 7 REINFORCEMENT(6063-T5 ALUM.) ALUM t z 9 RAIL` PVC o� 20 PUSH BUTTON SWEEPLOCK I 325" I o coo C3 MAIN FRAME 21 PUSH BUTTON SWEEPLOCK KEEPER lz 23 #7 X 3/B"PFH MS STEEL 2.31' 26 #6 X 1"PFH TEK SCREW STEEL Iw w 5 •THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY O ❑ o EXTRUDERS LICENSEES IN"AAMA CERTIFICATIONS PROGRAMS FOR RIGID PVC EXTRUSIONS". EO 0 0 1.32" 0.07, e a n o - NEXT GENERATION(DOW)OR _ © 0.065' INSTANT GLAZE III(DOW) 1"GLASS BITE ��1• I 7/8"THICKh--1.1T REINFORCEMENT 5 GLAZING BEAD Z LOCKS77LE N o N z Z 2.31" w z O 1/8"ANNEALED 1.51" �j o m �—0.090'DuPONT Butacite® I 2.59' w PVB INTERLAYER o ^ 1/8"ANNEALED L c m _ O.OT' O 1/8"ANNEALED L _ ❑� 0.07' 03 n N o v� m 1— 0.065' DAIS; 6119173 i u y SCALE N.T.S. STEEL SPACER I I DWO,BY: JK �T GLAZING DETAIL E DRA NLFS 3 PPULL,511[E ORAWWG .: IrNO R 41L MEETING STILE FL-15781.6 m 9 4 m SKEET 4 OF 4 N