HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 3
x. y
•-.. . •. " Yea
lit
,.. -- -
SCIS Home Log In � User Registration I Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map I Links I Search
Florida
;;® Product Approval
USER:Public User r
ttp.Nnnr. <
F,P.atuv:3�kni gra:
@, Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL5891-R5
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived ❑
Product Manufacturer Therma-Tru Corporation
Address/Phone/Email 118 Industrial Drive
Edgerton,OH 43517
(419)298-1740
rickw@rwbidgconsultants.com
Authorized Signature Rick Wright
rickw@rwbidgconsultants.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
® Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Lyndon Schmidt, P.E.
the Evaluation Report
Florida License PE-43409
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2018
Validated By Ryan J. King, P.E.
8 Validation Checklist-Hardcopy Received
Certificate of Independence FL5891 R5 COI Certificate of Indeoendence.pdf
Referenced Standard and Year(of Standard) Standard Year
SSTD 12 1999
TAS 202 1994
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDquw6mPIZhp%2f... 8/7/2017
Florida Building Code Online Page 2 of 3
Date Submitted 06/13/2015
Date Validated 06/28/2015
Date Pending FBC Approval 07/05/2015
Date Approved 08/18/2015
Summary of Products
FL# Model,Number or Name Description
5891.1 a. "FiberClassic" 6'8"Impact"Opaque Fiberglass Single Door(X)Inswing or
Outswing Configuration
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL5891 R5 II Inst 5891.1.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 5891.1 for Design Pressure Ratings by FL5891 R5 AE Eval 5891.1.odf
specific Model and for any other additional use limitations Created by Independent Third Party: Yes
and installation Instructions. (For FiberClassic doors,this
product approval requires the use of"J"part numbers for
these doors,which have been stained or painted within six
months of installation.)
5891.2 b. "SmoothStar" 6'8"Impact"Opaque Fiberglass Single Door(X)Inswing or
Outswing Configuration
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL5891 R5 II Inst 5891.2.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 5891.2 for Design Pressure Ratings by FL5891 R5 AE Eval 5891.2.odf
specific Model and for any other additional use limitations Created by Independent Third Party: Yes
and Installation instructions. (For SmoothStar doors,this
product approval requires the use of"J"part numbers for
these doors,which have been stained or painted within six
months of installation.)
5891.3 c. "ClassicCraft" 6'8"Impact"Opaque Fiberglass Single Door(X)Inswing or
Outswing Configuration
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL5891 R5 II Inst 5891.3.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 5891.3 for Design Pressure Ratings by FL5891 R5 AE Eval 5891.3.odf
specific Model and for any other additional use limitations Created by Independent Third Party: Yes
and installation instructions,
5891.4 d. "FiberClassic" 8'0"Impact"Opaque Fiberglass Single Door(X)Inswing or
Outswing Configuration
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL5891 R5 II Inst 5891.4.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 5891.4 for Design Pressure Ratings by FL5891 R5 AE Eval 5891.4.odf
specific Model and for any other additional use limitations Created by Independent Third Party:Yes
and installation Instructions. (For FiberClassic doors,this
product approval requires the use of"J"part numbers for
these doors,which have been stained or painted within six
months of installation,)
5891.5 e. "SmoothStar" 8'0"Impact"Opaque Fiberglass Single Door(X)Inswing or
Outswing Configuration
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL5891 R5 II Inst 5891.5.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 5891.5 for Design Pressure Ratings by FL5891 R5 AE Eval 5891.5.odf
specific Model and for any other additional use limitations Created by Independent Third Party:Yes
and installation instructions. (For SmoothStar doors,this
product approval requires the use of"J"part numbers for
these doors,which have been stained or painted within six
months of installation.)
5891.6 f. "ClassicCraft"
http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDquw6mPIZhp%2£.. 8/7/2017
Florida Building Code Online Page 3 of 3
8'0"Impact"Opaque Fiberglass Single Door(X)Inswing or
Outswing Configuration
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL5891 R5 II Inst 5891.6.Ddf
Approved for use outside HVHZ:Yes Verified By: Lyndon Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 5891.6 for Design Pressure Ratings by FL5891 R5 AE Eval 5891.6.1)df
specific Model and for any other additional use limitations Created by Independent Third Party: Yes
and installation instructions.
Back Next
Contact Us::2601 Blair Stone Road.Tallahassee Fl,32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Coovricht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your a-mali address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here
Product Approval Accepts:
® e0heek 0
Credit Card
Safe
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtD quw6mPIZhpD/D 2f... 8/7/2017
R W R W Building Consultants, Inc.
B Consulting and Engineering Services for the Building Industry
C P.O.Boz 230 Valrico,FL 33595 Phone 813.659.9197
Florida Board of ProfessionalEngineers Certificate of Authorization No.9813
i
Product Sub Category Manufacturer Product Name
Category
Therma Tru Corporation 3'0"x 6'8"
Exterior Swinging
Exterior Door 118 industrial Drive "Smooth Star"
Doors Assemblies Edgerton,01-143517 Fiberglass Single Door
Phone 419.298.1740 Inswing I Outswin "Impact"
Scope: This Is a Product Evaluation report issued by R W Building Consultants,Inc.and Lyndon F.Schmidt,P.E.for Therma Tru
Corporation based on Rule Chapter No.61 G20-3,Method 1 D of the State of Florida Product Approval,Department of
Business&Professional Regulation,
RW Building Consultants and Lyndon F. Schmidt,P.E.do not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of the product named
herein.
Limitations:
1. This product has been evaluated and.is in compliance with the 5th Edition(2014)Florida Building Code(FBC)structural requirements
excluding the"High Velocity Hurricane Zone"(HVHZ).
2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing
or stucco.
3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the FBC and does not
require an impact resistant covering.This product meets missile level"D"and excludes Wind Zone 4 as defined in ASTM El 996 and
Section 1609.1.2.2 of the FBC.
4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction.
5. Site conditions that deviate from the details of drawing FL-5891.2 require further engineering analysis by a licensed engineer or
registered architect.
6. See drawing FL-5891.2 for size and design pressure limitations.
Supporting Documents:
1. Test Report No. Test Standard Testing Laboratory Signed by
ETC 01-741-10700.0 TAS 202-94 ETC Laboratories Wendell W.Haney,P.E.
CTLA 98OW SSTD 12-99 Certified Testing Laboratories Ramesh Patel, P.E.
2. Drawing No. Prepared by Signed&Sealed by.
No.FL-5891.2 RW Building Consultants, Inc.(CA#9813) Lyndon F.Schmidt,P.E.
3. Calculations Prepared by Signed&Sealed by
Anchoring RW Building Consultants,Inc.(CA#9813) �� � r`rgp�� Lyndon F.Schmidt,P.E.
4. Quality Assurance ��3�, .� °L°�.-_�'� �����
Certificate of Participation issued by National Accreditation and
Management Institute,certifying that Therma Tru Corporation is `; ,3409
n �,
manufacturing products within a quality assurance program that complies T
with ISO/IEC 17020 and Guide 53. }a ,
r �
Lyndon F.Schmidt,P.E.
FL PE No.43409
1/29/2015
Sheet 1 of 1
THERMAITRU".
37-W MAX.O.A. _ .C►1
FRAME WIDTH
i�Y,,. 03� •�m
THERMA TRU DOORS
DTH
118 INDUSTRIAL DR., EDGERTON, DH 43517 �PA ELWI
//1111111 1 p n m Z
.•
(�
3.0.E v L,Q,� T
g t'�O m
Q cW
^ v v ay .0 10
"SMOOTH STAR" ® ® E o
FIBERGLASS SINGLE DOOR S14a
y
INSWING/OUTSWING NZ
"IMPACT' _ ' o A
�
Ed FW
Q
GENERAL NOTES F �
n N o a�
1. This product has been evaluated and is in compliance with the 5th Edition(2014)Florida Bulding
Code(FEC)structural requirements excluding the"High Velocity Hurricane Zone"(HVHZ). w a a
2. Product anchors shall be as fisted and spaced as shown on details.Anchor embedment to base 'm
material shall be beyond wall dressing or stucco.
e 3. When used in areas requiring wind bome debris protection this product complies with Section
1609.1.2 of the FBC and does not require an impact resistant covering.This product meets missile N
level"D"and excludes Wind Zone 4 as defined in ASTM E1996 and Section 1609.1.22 of the FBC. 0 4 Z
J-11Wo 2
9 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x NLA
N
buck masonry construction. o o
5. Site conditions that deviate from the details of this drawing require further engineering analysis f"
a by a licensed engineer or registered architect. CLa
6 _
TABLE OF CONiENIS ^^ `
N=a
� SHEETY DESCWFRON
OYEItALL DESIGN ARESSURE S m
s 1 Typical elevatwru,design pressures 8 general notes
2 Door panel details SWING fR/llA1 N^Z
1!/ftNEiYS10N PGSR11lE 'NEGATR/E'
3 Hor¢ontal cross sections : 4123108 zo
4 Vertcalcross sectionsINSWING 37.59"x82.19" +67.0 -67.0 sum N.T.S. 9
0 5 Buck and frame anchoring-2X buck masonry construction MO.BY: AL m'
6 Frame anchoring-1X buck masonry construction OUTSWING 37.59"x 80.69" +67,0 -67,0 eh•er: LFS 3
7 Bill of Materials 8 Components FR Ho No.: d
FL-5891.2 0
0
uSHWF__L or 7 0
R:\Oients\Therma Tru PERMANENT\Florida Product Approvals\FL-5891\Drawings\Cunent\FL-589Ldwg,2.2
4
O W
13o
O
02 v ® ® ® N N
Hy
°2
m
W
� � N
I I s
TIP PC
H Z Q
o
N
H
1.54"-�{� Z _
0.86,
In
J In
P
L
A
C A_
A
mn" X11111111//
Z A
_Z j N0.43409
PRODUCT: Document. Pnparw By: SLITB OF p
i B THERMA-TRU Lyndon F. Schmidt �i �OMOR�•'
IN o FIBERGLASS DOOR P. No. 43409 X11. . .NAI
o o W 2 1 28 15 UPDATE TO 5TH ED. 2014 FBC JBY
pAR7 OR ASSEMBLY: BUILDING CONSULTANTS/I4�j1`t`
IV N in 1 6 11 12 REVISED 70 2010 FBC DOOR PANEL DETAILS P.O. Box 230, Valrico, FL 33595
NO DATE Phone No.: 813.859.9197
REVISIONS FSPE CA No. 9813
®a0oe R.W.BIIILDINa CaneuLrANre IHc. '
R.'\Oieots\Therma Tru PERMANENT\Flodda Product Approvals\FL-5891\Drawings\Current\FL-5891.dwg,32
A
z
Z
v o m
v
w
v �
O Q (�
M
v PK
� ^ V
O M
�Q
T OO
y OD V
Q D •
z
Z ?W ® ® ® A
'-i
A .Z7
0 A
D
W W W N
Z
—�
W W M 2
N
0 0
Qa
A o
$ 0
x 2 OD V
O
Cr O O
n A
12 to
b n r
Z 7 D x
Z
M m e °
22 22 v
wN O O •.m `..
A A , m
g5g 2 v
j.7Q0
t0 H g'
n Q
ro n � aD V c
=A O •p
0 Q
N
h
CA
M
n O
Q
Z
P r
e e a
a. v
M
,`11111 I IIII ffffl
A .% F SCH A..f '.
No.43409all 1.
,
2fi-rs =*9 * •E
x PRODUCT; U �rlb Pnpana By: �� tfWEOF
oeum
THERMA—TRU Lyndon F. Schmidt 'i, AtoraO.�...
IW c Z N FIBERGLASS DOOR P.E. No. 43409
to r. -{ u 2 1 28 15 UPDATE 70 5TH ED. 2014 FBC LFS PART OR ASSEMBLY: GDn,/BUILDING CONSULTANTS�f INC.tI
rn- in�p 1 6 11 12 REVISED i0 2010 FBC JK eJ L_I/1/ P.O. Box 230, ValNeo, FL 33595
Iv �' NO DATE BY HORIZONTAL IVVV Phone No.: 813.859.9197
REVISIONS CROSS SECTION FBPE CA No. 9813
02DD8 R.W.BUILDING CDNBULTANTB IND.
R.'\Oients\Therma Tru PERMANENT\Florida ProductApprovals\FL-5891\Drawings\Current\FL-5891dwg,41
Z Z 0� °
g A M O
0 0 °
v
f00 n
r0,
Q O p a QO T tl,
N .. A ? A Fp V
m ° W
n N
s
Z Z
v'
v W 1-1/4"MIN.
EMB.)TYP.)
m
` nn
e 22
AA ''v Q atJ O
cpm A o a �m
o °
ro^ Fa o
o0 x
N .. n N t'
m ov .. ... lO >r m m
° v Go 0 O
2 Z �
OD V
v'
I-1/4"MIN.
EMB.)TYP.)
No.43409
4 4I PRODUCT: Bocum.nt, Pnpansd By: Q9UE CF
THERMA—TRU Lyndon F. Schmidt
L1 FIBERGLASS DOOR P.E. No. 43409 /�� ����
aLn fill 1�
cc y CN., 2 1 28/15 UPDATE TO 5TH ED. 2014 FBC LFS PART OR ASSEMBLY: GD BUILDING CONSULTANTS-,I�1 1L111
F in o 1 6 i 1 12 REVISED TO 2010 FBC JK eJL
IV N m VERTICAL P.O. Box 230, Vairioo, FL 33595
NO DATE BY CROSS SECTIONS Phone No.: 813.659.9197
REVISIONS FBPE C.A. No. 9813
0 20GB R.W.Bl1mmma CON—LTANT INC.
6 `Qom. ...... R4.
�z
o ''''''err/lll*1.11P1 11 11``````` za`p o
a Z
D
51 2
mo
MASONRY TYP.HEAD& — MASONRY C u$ 9 d`o a
OPENING JAMBS OPENING
54
�d
E ,z
3`d
FRAME K Nz
® ao
U, TYP.HEAD& ��
a s JAMBS u o =�
O NZ z FD ZZ
2 O
2X BUCK a O `� O EO
2X BUCK
�m
U
Uai
a }na DD
ai
v 'Y
DO
u' o
N
m cn
BUCK ANCHORING STRIKE JAMB FRAME ANCHORING HINGEJAMB W o S
Masonry 2X buck construction N 0)
CONCRETE ANCHOR NOTES: o o
1.Concrete anchor locations at the comers may be adjusted to maintain the min.
edge distance to mortar joints. a N
a 2.Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to i
a maintain the min.edge distance to mortarjoints,additional concrete anchors i
may be required to ensure the"MAX.ON CENTER"dimension are not exceeded. 9 m
a 3.Concrete anchor table: UJ
28 K r-
n ........................
.. N tD
MC1N C{��kftANC� MIN ClVA4ANC�
,4NCHOR ANCfldk;:?;°;•i;.MIN 10 m
'..TYPE s►�I Eti1gEdAM�N1 70 MASONRY 70 ADJACENT 10 N'Z
W EDGE..::. ... .:...ANCHOR::.:` K e
Rw 27 p Z 4/23/08
® 1/4" 1-1/4" 2" 4" v
TAPCON scams: N.T.S.
W ELCODWG•rir: AL m'
F 1/4" 1.1/4" 1" 4"
ULTRACON® CHK.BY: LFS ;
€ WOOD SCREW INSTALLATION NOTES: DRAWING NO,
1.Maintain a minimum 5/8"edge distance,1"end distance,&1"o.c.spacing HINGE DETAIL LATCH d DEADBOLT DETAIL FL-5891.2 0
n of wood screws to prevent the splitting of wood. N
o sNaa 5 or 7 0
d
�6" Z' O.'' m
wyj
� 1mn
6 it Pi
OK
\ HI
/111111 1zO r4 O
a N 2
a v O Q Z
ci
MASONRY EVX)'*m a a a'
OPENING \(� D- 7
CZ
FRAME 28 G 3 �,�
8 �d
J
FRAME
TYP.HEAD& 27 ❑ C' � =m,
T—
JAMBS `*v o x
O d z no —:�
1X BUCK N w� :E �}
=
LATCH&DEADBOLTDETAIL ~ �o
7 L§
O
K Q
D. a
ci
� a
N U
STRIKEJAMB FRAME ANCHORING HINGE JAMB w z
Masonry 1 X buck construction w o 0
Fo Ln
N
CONCRETE ANCHOR NOTES: o o
_ 1.Concrete anchor locations at the comers maybe adjusted to maintain the min. o
Na W W edge distance to mortarjoints. <�,
2.Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to $
maintain the min.edge distance to mortar joints,additional concrete anchors H 9 ' z
I—!
maybe required to ensure the'fv1AJC.ON CENTER"dimension are not exceeded.3.Concrete anchor table: 10oOHOR e EQMNJO _o 0
.......TYPE,:.:;.......S.E 1. :;::;EDGE:::::::::::::: CNOR:::;si; z v
...................... ..............::.::::.-::::::::::::::::::::::::::::.:::::::.
ITNDATE: 4/23/08 °
TAPCON® 1/4" 1-1/4" 2" 4" sr.ir. N.T.S. 9
e ITW 3/16" 1-1/4" 3" 1-1/2" DWG.SY: m'
~ TAPCON® CHK ar: LFS 3
€ WOOD SCREW INSTALLATION NOTES: HINGE DETAIL DRAWING NO.: �
n1.Maintain a minimum 5/8"edge distance,I"end distance,&I"o.c.spacing FL-5891.2 0
of wood screws to prevent the splitting of wood. n
fsHEEr 6 of 7
d
BILL OF MATERIALS ��i �► m
ITEM DESCRIPTION MATERIAL =_' a * Q n
A 1X BUCK SG>=0.55 WOOD =V01 �
8 2X BUCK SG>=0.55 WOOD N•
�—4.56 = �•
C MAX.1/4"SHIM SPACE WOOD
D 1/4"X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL
'��ii *P,�'%%%
E MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI CONCRETE o am 0
301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 fn
G 3/16"X 3-1/4"PFH ITW CONCRETE SCREW STEEL o �—2 '�� k o E m z m u v
H 114'x 3-1/4"PFH ITW CONCRETE SCREW STEEL e N g 9 0
20a
J 1/4"X 3-3/4"PFH ITW CONCRETE SCREW STEEL a
K #8 X 2-1/2"PFH WOOD SCREW STEEL 19 20
QEAb a SIDE c d
L #10 X 7'PFH WOOD SCREW S1EEL E $_
7 SHORT REACH COMPRESSION WEATHERSTRIP FOAM ",a:
8 LONG REACH COMPRESSION WEATHERSTRIP FOAM
9 4'X 4"HINGE.097'THK. STEEL
10 #10 X 3/4"PFH WOOD SCREW STEEL
17 KWIKSETSIGNATURE SERIES PASSAGE LOCK STEELIn
o
18 LOW PROFILE OUTSWING BUMP FACE THRESHOLD ALUM./WOOD o W z
I I
19 HEADER JAMB PINE,S.G.-0.42 WOOD L Ln
20 SIDE JAMB PINE,S.G.>=0.42 WOOD m §cD s a-
21 KWIKSET SIGNATURE SERIES 780 DEADBOLT STEEL
27 LATCH STRIKE PLATE STEEL I— —4.67'
28 DEADBOLT PLATE STEEL
ry 32 DOOR BOTTOM SWEEP PVC 0 ~
33 SELF ADJUSTING INSWING SADDLE THRESHOLD ALUM.COMP. �1[OW PROFILE OUISWING BUMP FACE a a
40 FIBERGLASS DOOR PANEL-SMOOTH STAR m
41 SS DOOR SKIN.070'MIN.THK.FIBERGLASS BY SMC v
i
THERMA-TRU WITH YIELD STRENGTH Fy(MIN.)=6,000 PSI
t 42 TOP RAIL COMPOSITE v
3 43 LATCH STILE LVL WOOD N
" 44 HINGESTILE WOOD In z
45 BOTTOM RAIL COMPOSITE w o 0
46 POLYURETHANE FOAM CORE-1.9 LBS.DENSITY FOAM 5.75' —{ n N N
47 LOCK BLOCK REINFORCEMENT WOODEi
I o o
NOTE:WOOD/LVL COMPONENTS(PINE,SG 0.42) �, a yy
a
1:310:1 i
e r W 9
N=a
^mo �
o_
lF ADJUSi1NG SADDIE TNRESHOIDADJUSi1NG SADDIE TNRESHOID z El
OAIE 4/23/08 i
SCALL N.T.S.
2 owc.BY: AL m
CNK.BY: LFS 3
DRAPING NO.:
FL-5891.2 0
sNCEr 7 ov 7 N
O
e2