Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2 I( {gyp `kA. „m�.,�n'•v�ytly^.uyu 3eS�'�.- I is rt. I �1 r.�. 13QS Home :.Log In User Registration Hot Topics Submit Surcharge Stats&Fads Publicat(orks-; FBC Raft SOS Site Maps Links i Search �. Florida �} blrj�t Product Approval {I USER:Public user Product Anaroval Meny>Product or Anoiicetion Search>AurAlotion LEct>AppitcationCetall FL# FL18355-113 Application Type Revision Code Version 2014 Application Status Pending FBC Approval Comments Archived Product Manufacturer TAMKO Building Products,Inc. Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri_eden@tamko.com Authorized Signature Kerri Eden kerri_eden@tamko.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 11 Evaluation Report-Hardcopy Received Florida Engineer-or Architect Name who developed Zachary R.Priest the Evaluation Report Florida license PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 01/07/2019 Validated By Locke Bowden W, Validation Checklist-Hardcopy Received Certificate of Independence FLIS355 R3 COI TBP15001.3 FBC 2094 Product Evaluation Report Shingles.0 Referenced Standard ar and Year of Standard Standard Year ASTM D 3161 2009 ASTM D 3462 2009 ASTMD D 7158 2008 TAS 100 1995 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDquvosrHazGXQ... 6/14/2017 Florida Building Code Online Page 2 of 2 Product Approval Method Method I Option D Date Submitted 05/09/2017 Date Validated 05110/2017 Date Pending FBC Approval 05/15/2017 Summa ry of Products PL# Model,Number or Name Description 18355.1 Glass-Seal,Elite Glass-Seal,. ASTM D 3462 asphaltshingles and hip and ridge shingles Heritage,Heritage Premium, Heritage Woodgate,Heritage Vintage,Hip and Ridge,and Vintage Hip and Ridge Shingles Limits of Use installation Instructions Approved for use In HVHZ.Yes FL18355 R3 11—TSP15001_3 MC 2014 Product Evaluation Approved for use outside HVH7_Yes Report Shinoles.pdf Impact Resistant,N/A Verified By:Zachary R.Priest PE-74021 Design Pressure:N/A Created by Independent Third Party:Yes Other.See evaluation report for limits of use. Evaluation Reports FL18355 R3 AE TSP15001.3 FBC 2014 ProductEvaluation Report Shingles.pcif Created by independent Third Party:Yes Back FEE Contact Us::2601 Blair Slone Road.Tallahassee FL 32399 Phone:850-487-1,024 The State of Florida is an ANEW employer.Copyright 2007-2013 State ofFlorida.::Privacy SWtemen Refund Statemen Under Florida law,email addresses are pubtic records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.0 you have any questions,please contact 650.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address it they have one.The emails provided may be used for official communication with the licensee.However e mall addresses are public record.If you do not wish to supply a personal address,please provide the Department with an emall address vilinch can be made avaltable to the public.To determine if you are a licensee under Chapter 455.F.S.,please dick him. Product Approval Accepts: Credit Card Safe hos://wv�-w.floridabuildinL7.org/pr/pr app__dt1.aspx?pararn---wGEVXQwtDquvosrHazGXQ,... 6/14/2017 3 Certificate of Authorization No.29824 17520 Edinburgh Dr EEK Tampa,FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLOEUDA BUILDING CODE a EDITION(2014) Manufacturer: TAMKO BUILDING PRODUCTS Issued May 9,2097 220 West 4th Street Joplin,MO 64801 (417)62446644 Manufacturing Plants: Joplin,MO Phillipsburg,KS Frederick,MD. Dallas,TX Tuscaloosa,AL Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: Asphalt Shingles Code Sections: 1507.2.5,1507.2.7.1, 1523.6.5.1 Properties: Physical properties,Wind Resistance,Wind Driven Rain REFERENCES Enti Report No. Standard Year PRI Construction Materials Technologies(TST5878) TAP=043-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-051-02-01 TAS 100 1995 . PRI Construction Materials Technologies(TST5878) TAP-054-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-114-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TRP-117-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-130-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-131-02-01 TAS 140 1995 PRI'Constniction Materials Technologies(TST5878) TAP-165-02-01 TAS 100 1995 PRI Construction Materials-Technologies(TST5878) TAP-280-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-303-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-307-02-01 TAS 100 1995 PRI Construction.Materials Technologies(TST5878) TAP-314-02-01 Rev 2 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-315-02-01 ASTM D 6381 2008(2013)e1 PRI Construction Materials Technologies(TST6878) TAP-317-02-01 TAS 100 1995 UL LLC(TST9628) 02NK9507 ASTM D 3161 2009 UL LLC(TST9628) 04NK24366 ASTM D 3462 2009 UL LLC(TST9628) 05NK28006 ASTM D 6381 2008(2013)e1 UL 2390 ASTM D 7158 20084 UL LLC(TST9628) 06NK03898 ASTM D.31.61 2009 ASTM D 3462 2009 UL LLC(TST9628) 08CA59132 ASTM D 3161 2009 UL LLC(TST9628) 09NK07896 ASTM D 3161 2009 ASTM D 3462 2009 UL LLC(TST9628) 1 OCA50498 ASTM D 3462 2009 UL LLC(TST9628) 10CA64882 ASTM D 3161 2009 UL LLC(TST9628) 11NK14014 ASTM D 3161 2009 ASTM D.3462 2009 UL LLC(TST9628) 12CA24551 ASTM D 3161 2009: UL LLC(TST9628) 4786110543 ASTM D 6381 2008(2013)e1 UL LLC(TST9628) 4787043752 ASTM D 3161 2009 I UL LLC(TST9628) 4787148748 ASTM D 7158 20084 ASTM D 3161 2009 ASTM D 3462' 2009 CREEK Technical Services LLC(ANE11669) TBP15001.3 Calculations 2017 TBP15001.3. FL18355-R3 Page 1 of 11 This evaluation report is provided for,State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. i r. TAMKO BUILDING PRODUCTS CREEK Asphalt Shingles TF-cHNICAL SERvicEs,LLC PRODUCT DEScRipnoN Elite Glass-Seal@ 12-114"x 36",ASTM D 3161, Class F and ASTM D 7166, Class H self-sealing, 3-tab (Frederick,Joplin I asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D-M62. Glass-Seal 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-,sealing, 3-tab (Frederick& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass-Seal 12!.1/4"x 36',ASTM D 7158,Class H self-sealing,3-tab'asphalt shingle with fiberglass (Joplin) mat coated on both sides,with asphalt and surfaced with ceramic granules complying with ASTM D 3462. Shingles shall be used in the nonA_NHZ only. Heritage@ 13-1/4" x 39-318", ASTM D 3161, Class F and ASTM.D 7158, Class H fiberglass (Dallas,Frederick reinforced, laminated architectural asphalt shingle surfa ced with mineral granules Joplin,Phillipsburg& complying with ASTM D 3462. Tuscaloosa) Heritage@ Premium 1.3-1W x 39-318", ASTM D 3161, Class F-and ASTM D 7158, Class H fiberglass (Dallas,Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Phillipsburg& complying with ASTM D 3462. Tuscaloosa) Heritage®Premium 12" x 36", ASTM D 3161, Class F and ASTM.D 7158,. Class H fiberglass reinforced, (Frederick) laminated architectural asphalt shingle surfaced With mineral granules complying with ASTM Q 3462. HerltageOVintageO 17-1/2"x 40".ASTM D 3161, Class F and ASTM D 7168, Class H fiberglass reinforced, (Phillipsburg) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 34621. HeritagepWoodgate 13-1/4" x 30-3/8', ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas&Frederick) reinforced, laminated, architectural asphalt shingle surfaced with mineral granules complying with ASTM D 31462. Herit6ge(Moodgate 12-x 36-3/8', ASTM D 3161, Class F fiberglass reinforced, laminated architectural (Frederick) asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Hip and Ridge Shingles 12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt (Frederick&Joplin) shingle surfaced with mineral granules complying with ASTM D 3462. Vintage@ Hip and Ridge 12" x 12', ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle (Phillipsburg) surfaced with mineral granules complying with ASTM D 3462. TBP15001.3 FL18355-R3 Page 2 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. TAMKO BUILDING PRODUCTS CREEK Asphalt Shingles TECHNICAL SERVICES,LLC INSTALLATION Elite Glass-Seal@ Basic Wind Speed(VuO,: Max. 194 mph (Frederick,Joplin& Basic Wind Speed(Vasa): Max. 150 mph Tuscaloosa) Deck(HVHZ).- In accordance with FBC requirements; & Solidly sheathed min. 19132.in. plywood or wood plank for Glass-Seal new construction; Min. 15/32 in. plywood existing (Frederick Joplin(Non- construction. HVHZ)& (Frederick, Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction;Min.7/16.1n,OSB existing construction. Underlayment In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application-instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed with-5-118 inch exposure in accordance with RAS 115 and manufacturer's published'installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5-'U8-inch-exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. NAILS Nailing -7 Ar6a .. ....... ..... . .. ................I ...... 0 BW fte Figure 1. Elite Glass-Seal&Glass-Seal 4 Nail Pattern(Non-HVHZ only) NAILS ............ ....... Area ............ Butt Edge Figure 2. Elite Glass-Seal&Glass-Seal 6 Nail Pattern TBP15001.3 FL18355-R3 Page.3 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. TAMKO BUILDING PRODUCTS CREEK Asphalt Shingles TecHNICAL.SF-RvicEs,LLC Hentage@ Basic Wind Speed(Vui): Max. 194 mph (Pallas,Frederick,Joplin, Basic Wind Speed(Vad): Max. 150 mph Phillipsburg&Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements', & Solidly sheathed min. 19/32 in. plywood or wood plank,for HerltagOD Premium new construction; Min. 15/32 in. plywood existing (Dallas,'Frederick construction. Phillipsburg&Tuscaloosa) Deck(Nm-HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 15/32 in. plywood or wood plank for Heritage@.Woodgate new construction;Min.7/16 in.0813 existing construction. (Dallas&Frederick) Underlayment: In accordance with FBC requirements. Min.slope: 2,12 and in accordance with FBG requirements. Refer to The mahulticturer's application instructions when installing shingles at slopes greater than 21:12. Installation(W,HZ): Installed with 5-5/8 in. exposure in accordance with RAS 115 and manufacturers published installation instructions. Shingles shall be attached using "6 Nail Pattem" detailed below. Installation (Non-HVHZ):, Installed with 5-5/8 in. 'exposure in accordance with FBC requirements and manufacturers published installation instructions. Shingles shall be attached using elther"4 Nail Pattern"or"6 Nail Pattern"detailed,below. FASTENERS NAIL ZONE GOM MON 0/80ND all EXRosURE 6-6/9' 12-11211 12-3/811 2-1/2"� i111-1 Figure 3. HeriltageS,Heritage®Premium,and Heritage@ Woodgate(Dallas) 4 Nail Pattern(non-HVHZ only) FASTENERS NAIL ZONE COMMON BOND EXPOSURE 5-518° Figure 4. Heritage®&Heritage@ Premium 6 Nail Pattern f TBP15001.3. FL18355-R3 Page 4 of 11 This evaluation report is provided for State of Ronda product approval under-Rule 61G20-3. The manufacturer shall notify CREEK 1. Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. TANIKO BUILDING PRODUCTS_ CREEKAsphalt Shingles TF-c-INICAL SvrPVIGES,L.LC NAIL ZONF! ASTENERST�' '�"" COMMONSON '` EXPOSURE 5 US" 1° �F7-112:►�+�•7-112'M��7-318=►�/�7-912s1�+F7-1/2� �-�'" Figure 6. Heritage®Woodgate 6 Nail Pattern -►�t"�1"i+-- 12-112"--=• i�----12-1/2"-----►�1r,1„�+- i i r �, Common Bond FASTENERS i. � �•�aD'7r'.�4;.t a',.;s,"^--moi •it:}:4. ��'2�':c.:�: v r3Y. '??'�-'^'�,.t:�xo':r:ct. -- T m I H r 39-318” i Figure-6. HeritageO,Heritage@ Premium,&Herltage@ Wraodgate Alternate 6 Nail Pattern PAINT CINE NAIL ZONE. fi=1IS" -EDGE OF. COMMON BOND EXPOSURE 5-518° ACCEPTABLE FASTENER LOCATION DO NOT FASTEN ALONG=EDGE OF COMMON BOND PREFERRED. FASTENER LOCATION Figure 7. Heritage@(Tuscaloosa) Expanded Nail Zone Nail patterns from Figures 3,4,and 6 may be placed In the nail zone as described above TBP15001.3 FI-18355-R3 'Page 5 of 11 i This evaluation report is provided for State of Florida product.apprpvai under Rule 61620-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration.for which this report is valid. This evaluation"report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically_addressed herein. TAMKO BUILDING PRODUCTS ACREEKAsphalt Shingles TECHNICAL SERVICES, LLC Heritage®Premium Basic Wind Speed(Vwt): Max. 194 mph (Frederick) Basic Wind Speed(Vaa): Max. 150 mph Deck(HVHZ): In accordance-with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood.plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): in accordance with FBC requirements; Solidly sheathed min. 15132 in..plywood or wood plank for new construction;Min.7/16 in.OSB existing construction_ Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. . Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC .requirements and manufacturer's published installation instructions. Shingles shall be attached using:either"4 Nail .Pattern"or"6 Nail Pattern"detailed below. NAIL ZONE/ FASTENERS COMMON BOND 5112° rEOVO-SUPRE 5° 1"."� �-- 11"--►�-- 12" 11"—►� �1 n Figure 8. Heritage@.Premium(Frederick) 4 Nail Pattern (non-HVHZ only) NAIL ZONE/ FASTENERS4,/COMMON BOND 511x" EXPOSURE 5° 9u o 9112" 14-1 It Figure 9. Heritage@.Premium(Frederick) 6 Nail Pattern i TBP15001.3 FL18355-R3 Page 6 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty;installation,recommended use,or other product attributes that are not specifically addressed herein. i s TAMKOBUILDINGPRODUCTS CREEKAsphalt Shingles TECHNICAL SERviCE5, LLC Heritage®Woodgate Basic Wind Speed(V,et): Max. 194 mph (Frederick) Basic Wind Speed(Vasd): Max.150 mph. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min.7/16 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation (Non-HVHZ): Installed with 5 in. exposure, in accordance with FBC requirements andmanufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern'or"6 Nail Pattern"detailed below. NAIL ZONE/ FASTENERS COMMON BOND Ar n - EXPOSURE 5P 1�� 1�� �'►�--12-31$"— — 11" --►I ..1st Figure 10. Heritage®Woodgate.(Frederick) 4 Nail Pattern(non-HVHZ only) NAIL ZONE/ FASTENERS COMMON BONA r1/2" EPOSURES" 1"-"� N-9-112"-►If3'��--918"-►�FB'�-8-112"-M� �-1 Figure 11. Heritage®Woodgate(Frederick) 6 Nail Pattern TBP15001.3. FL18355-R3 Page 7 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. TAMKO BUILDING PRODUCTS JCREEK Asphalt Shingles TECHNICAL SERVICES, LLC Heritage®Vintage® Basic Wind Speed(Vut): Max. 194 mph (Phillipsburg) Basic Wind Speed(Va-,d): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15132 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32.in._plywood or wood plank for new constructlon Min.7/16 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements.. Refer to the manufacturer's application instructions when installing shingles at slopes greaterthan 21:12. Installation(HVHZ): Installed with 5 in. exposure-in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5 -in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"5 Nail Pattern"or"6 Nail Pattern"detailed below. rxposure T rbt<n Fa3teners t�1 ane — — — — ——— —— — — — — — — 5" rxpMun: 9.111' 9•IM 9.1M'—�—A7M` Figure 12. Heritage®Vintage® 5 Nail Pattern (non-HVHZ only) - �' F7t♦f06YR Nowt T � T tf F�QIlR Noll zam 17-11t r Figure 13. Heritage®Vintage® 6 Nail Pattern TBP15001.3 FL18355-R3 Page 8 of 11 This evaluation report is provided for State of Florida product approval under Rule 61020-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not. specifically addressed herein. TAIVIKO BUILDING PRODUCTS CREEK Asphalt Shingles TE:cHNICAL SF-Rvicirs,LLC Hip&-Ridge Basic Wind-Speed(Vta): Max. 194 mph, (Frederick&Joplin) Basic Wind Speed(Vmd): Max.- 160 mph Deck(HVHZ): In accordance with FBC requirements; Solidly-sheathed min. 19132 in. plywood or wood plank for new construction; Min. 15132 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32.in. plywood or wood.plank for new construction,Min.7116 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Installation* -installed with 5-1/8 inch exposure in accordance.with the FBC and manufacturers published installation instructions. The direction of the exposed end shall be away from the prevailing Wind. Direction of prevailing wind Start 5-1/8" exposure Start hered Figure 1 5-IN'exposure ivy Fas#e % nerastener _ 41 wall Figure 2 IMF Figure 3 Figure 14. Hip&Ridge(Frederick&Joplin) TBP15001.3 FI-18355-113 Page 9 of 11 This evaluation valuation report is provided for State of Florida product approval under Rule,61G207.3. The manufacturer shall notify.CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. TAIVIKO BUILDING PRODUCTS CREEK Asphatt Shingles TF-CHNICAL SF-RVICF-S,LLC VintageO Hip&Ridge Basic Wind Speed(Vot): Max. 194 mph (Phillipsburg) Basic Wind Speed(Vasa): Max.150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15132 in. plywood existing construction. Deck(Non-HVHZ): In accordance with.FBC requirements; Solidly sheathed min. 15132 in. plywood or wood plank for new construction;Min.7116 in.OSB existing construction. Underlayment.. In accordance with FBG requirements. Min.slope: 2:12 and in accordance with FBC requirements. Installation: Installed with 5 inch exposure in accordance with.the FBC and manufacturer's published installation instructions. The direction of the exposed end shall be away fromthe prevailing wind. Direction of prevailing wind. ftrt 51'exposure here- AN A Suit <Man Figure I here exposure gel lop ter Fasteroer Fastener Figure 2 Figure 3 Figure IS.. VintageD.Hip&Ridge(Phillipsburg) TBP15001.3 FL18355-R3 Page 10 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes thatare not specifically addressed herein. TAMKO BUILDING PRODUCTS SCREEK Asphatt Shingles TECHNICAL SERVICES,LLC LIMITATIONS= 1) Fire Classification is not within the scope of this evaluation.- 2) The.roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 3) The mean roof height shall.be restricted to a maximum 33 ft in-the HVHZ. 4) Classification to ASTM D 7158 applies to exposure B&C with a building mean roof height of 60-ft or less. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected promo underiayment application. 6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. 7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturers published application instructions. Where discrepancies exist between these sources, the more restrictive and code compliant detail shall prevail. 8) All products listed in'this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 5th Edition(_2014)as evidenced in the referenced documents submitted by the named manufacturer. t%IiIIII++++r',! N& No 74021 2017.05.09 15:06:10 =o :�. STATE OF 4U ...�... .� `04'00' 10 0;<,, �- ?• �4✓;� ZacharyR.Priest, P.E. Florida SS . Organization No AE11669 1 tle ii I I CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. GREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest,P.E.does,not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this,evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT TBP15001.3 FL18355-R3 Page 11 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20.3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or.quality assurance changes'throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein.. , odds Building lode Online- https://www.floridabuilding.org/pr/pr_app dti-aspa?param=wGEVX... r ! e.:'-KL ,..:.C�,.«ww..,.�rt.iv�R... 6CIS Nome tog fn User Regffirstbn Hot 7bpis Submit Surcharge Stats 6 Fads Fubkatbns FBC Start BM Site Map links Search U�St��s5',l't j! ��a eSSK)i1d f Produce Approval { F tt USER:Aiblt User l ai i,)* PmdqFt aJ2rayt t_tde�it>Frock ar An,rAtl�n&aa h>9P.t? 19!l ll£t>ApP�tlon MON xr,v z FL tf F1.16048-113 --�• Application Type Revision Code-Version 2014 Application Status Approved Comments Archived Product Manufacturer TRI-BUILT Roofing Products Address/Phone/Emaki 9050 Louisiana Street Merrillville,IN 46410 (201)842-2449 david.rulz@tribuiltmaterkalsgroup.com Authorized Signature David Rutz david.ruiz@tribuiltmateriaisgroup.com Technical Representative David Ruiz Address/Phone/Email 250 Route 17 North East Rutherford,NI 07073 (201)842-2449 david.ruiz@tribuiltmaterlaisgroup.com Quality Assurance Representative Address/PhonpiEmail Category Roofing Subcategory Underkayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/16/2027 Validated By John W.Knezevlch,PE Validation Checklist-Hardcopy Received Certificate of Independence FL16048 R3 COI 2015 02 COI Nlegloen.odf Referenced Standard and Year(of Standard) Standard UAL ASTM D1970 2409 ASTM G155 2005 FRSA/TRI April 2012(04-12) 2012 TAS 103 1995 I of 2 5/24/2016 9:58 AM orida Building Code Online https://www.floridabuilding.org/pi/pr app dtl.asPx?paraln=wGM._. Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method i Option D Date Submitted 10/08/2015 Date Validated 10/19/2015 Date Pending FBC Approval 10/21/2015 Date Approved 12/15/2015 Summary_of_Products -FL# 'Model,Number or Name Description 16048.1 TRI-BUILT Roof Undedayments Self-adhering,modified bitumen roof underlayments j !'Limits Of Use �—��------- --�—;Installation Instructions Approved for use In HVHZ:No FLI6048 R3_II 2015 10 FINAL ER TRl Approved for use outside HVHZ:Yes BUILT UNDERLAYMENTS FL1 8=R3.pd_f Impact Resistant:N/A Verified By:Robert Nieminen PE-59166 Design Pressure: +N/A/-45 Created by Independent Third Party:Yes Other:1.)The design pressure noted herein pertains to use i Evaluation Reports of foam-on tile systems overtop the self-adhering FL16048 R3 RE2015 30 FINAI ER fRb underlayment for one particular application.See ER Section :BUILT UNDER LAYMENTS;FL6048-R3.pdf 5.6 for details.2.)Refer to ER Section 5 for other Limits of Created by Independent Third Party:Yes Use. Eitlr Nmtt' SdtD W_(15:;1940 North Mon@e_;1reEt.Tafbhassee FL,32399 phone:850-487-1824 The State of Florida Is an AA/EEO employer.S,QWjMftM07_-2Q13 State of Florida,;:Privacy Statement;:ACQMIUM Staterrienl;;$S(nidAialemed Under Florida law,email addresses are public records.If you do not want your e-mail address teleased in response to a puNlic-retorts request,do not send eiect xmic mal to thtsenttty.Instead,contact the office by phone or by traditional mail.9 you have'any questions,please Contact 850.487.1395, Pursuant to SectloD 455.275(1),Fbrida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an emall address 9 they have one.The emails provkied may be used for official commummtlon wth the licensee.However emal addresses arc public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made avallatae to the public.To determine I you are a licensee under Chapter 455,F.S.,phase click hes. Product Apprrwal Accepts: kid- F3, ,,-rurlttyy, ,: 2 of 2 5/24/2016 9:58 AM EXTERIOR RESEARCH&DESIGN,I.I.C. Certificate of Authorization#9503 IITY M 353 CHRISTIAN STREET,UNIT#13 OXFORD,CT 06478 PHONE:(203)262-9245 EVALUATION REPORT FAX:(203)262-9243 Allied Building Products Corp. Evaluation Report A42960.20.12-113 dba TRI-BUILT Roofing Products F1.16048-113 9050 Louisiana Street Date of Issuance-1014S/2012 Merrillville,IN 46410 Revision 3: 10%08/2015 SCOPE: This Evaluation Report is.issued under Rule 611320-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida..The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida .Building-Code, Residential Volume. The products described herein have been evaluated for compliance with the 5`l" Edition (2014) Florida Building Code sections.noted.herein. DEsCRJlPnoN: TRI=BUILT Roof Underlayments LABELING: Labeling;shall be in accordance with the-requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation changes,or.provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by thenamed client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinity ERD Evaluated" may be displayed in advertising literature. if any portion of the Evaluation Report Is displayed,then it shall be done in its entirety. INsPEcnoN:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5. Prepared by: .L. 've Robert J.M.Nieminen,P.E. ''r:'s� •I L4 The facsimile seal appearing was authorized byRobert Nieminen. �Jp,; ,,.+s``• P.E.an 10/06/2015:This Coes not serve as an eleetronkally signed Florida Registration No.59166,Florida DCA ANE1983 document:Signed,sealed hardcoples have been transmtted to the Product Approval Administrator and to the named chem CERTIFICATION OF INDEPENDENCE: 1. Trinity 1 ERD does not have; nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen,P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERD ROOFING COMPONENT EVALUATION: I.- SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: TRI-BUILT Roof Underlayments,as produced by TRI-BUILT,have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance With the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4,1507.2.8,1507.1;9.2, Physical Properties ASTM D1970 2009 1507.4.5..1,1507.5.3,1507.7.3 1504.6 Accelerated Weathering ASTM G155 2005 1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012 1523.6,5,2.1 Physical Properties TA5103 2995 3. REFERENCES: Kaft Examination Reference Date ERD(TST6049) Physical Properties 540540.02.13-1 02/15/2013 ERD(TST6049) Physical Properties 54 6546.11.13 6546.11.13 11/19/2013 ERD(TST6049) Physical Properties S40540.03.14 03/26/2014 ERD(TST6049) Physical Properties 544870.04.14-2 04/02/2014 ERD(TST6049) Physical Properties 544870.04.14-3 04/02/2014 ERD(TST6049) Physical Properties S44870.04.14-1 04/10/2014 ERD(TST6049) Physical Properties 544870.04.14-4 04110/2014 ERD(TST6049) Physical Pioperties 543530.02,14-1-R1 05/14/2014 ERD(TST6049) Physical Properties 543530.05.14 05/28/2014 ERD(TST6049) Physical Properties 540540.10.14 10/31/2014 ERD(TST6049) Physical Properties SC7645.02.15 02/13/2015 ERD(TST6049) Accelerated Weathering SC8520.04.15 05/27/2015 UL,LLC.(QUA9625) Quality Control Multiple-Listing 816814 09/04/2015 UL,LLC,(QUA9625) Quality Control Service Confirmation Exp.10/16/2017 4. PRODUCT DESCRIPTION: 4.1 Self-Adhering Underlayments: 4.1.1 Tei-Built Sand-11 SA Shingle Underlayment is. a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,with a 36-inch sheet width. 4.1.2 Tri-Built S/A HT TU Underlayment is a self-adhering, non-woven polyester fabric surfaced, SSS modified bitumen roof underlayment 4.1.3 Tri-Built Smooth HT S/A Underlayment is a self-adhering,glass-mat reinforced,film-surfaced,SOS modified bitumen roof underlayment. S. LimrrAmONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E, are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this'Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,LLC. Evaluation Report A42960.10.12-113 cervTKate of Auth"Itation#9503 FL160418­113 Revision 3:10/08/2015 Page 2 of S _ | | ' TRINITY ��^�'��[� �herethepnoduct�spec�caUy 5.4 �F�!���Vn���mmsm�be����a�pm�ed roof�� referenced within FBCapproval documents. -If not listed,arequest maybe made tnthe AH]for approval based on this evaluation combined with supporting data for the prepared roof covering. S.5 Allowable roof covers applied atop the un6edaymentsare asfollows: Underlayment Asphalt Nall-On Tile Foam-On Tile Metal Wood Shakes late Mingles &Shingles S Tri-Built Sand-R SA Shingle Yes, No No No Yes Yes Undedayment Tri'-8uilt S/A HT TU Yes Yes Yes Yes Yes Yes Underlayment See 5.5.1 Tri-Built Smooth HT S/A Yes No No Yes Yes Yes Underlaynient I i 5S.1 "Foam-On TUe^ is limited to use nfthe following Approved We adhesives unless tensile adhesion/long term aging data from anaccredited testing laboratory isprovided. > Tri-Built SIA HTTUVndedaymentwith 3141 2-CumponentRoof Tile Adhesive AH'1su(FL63a2)nrDow ll|eBond'fi*Roof Tile Adhesive(pr/17) 5.6 Allowable substrates are noted below: 5.6.1 : Tri-Built Sand-ASAShingle Undedoyment,Tri-Built SIA HTTDUnde,laymenturTri-Built Smooth w/ S/a Undaiaynesuapp|ied to: � Plywood; ASTM D41 primed plywood; OSB; ASTM 041 primed n8B; uzTw1 D41 primed structural ' concrete. While not.required over plywood,OSB or Southern Yellow Pine substrates,TRI-BUILT recommends priming the deck if the final ,uofcmver'|s not slated for installation o,itbm 24 hours. mote: Tn|'oNcr requires ` tongue-and-groove board decking be covered with plywood o, OSB prior to installation of the self- adhering underlayment. e/f'adhe,ingundedaymunt. ' 5.6.2 : Tri-Built S/AHTTVUn6arlaymentapplied to: ' > Dens Deck phme;-SECUROCK Gypsum-Fiber Roof Board. � For installation under mechanically attached prepared roof coverings, insulation shall be attached per ` minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations ' under foam-on Vile systems,insulation attachment shaOhedesigned byaqualified design professional and � installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D nrTAS 114,Appendix 1 6.6.3 Bond to Methanically Attached Base Laver: For installations under mechanically attached prepared roof coverings, bate layer shall be attached per minimum codified requirements. For installations under foam-on tile systems,base layer shall beattached per minimum requirements ofFRSA/T.R\April 2012([4-12). Exterior Researth and Design,LLC_ Evaluation Report A42960.20.12-m3 c*vnwm of^"oa^*vm"ws03 nL160*&e3 Revision�xam81ao-IS Page novs TRINITY ERD 5:6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRi April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on the systems,where the underlayment forms part of the load-path. The following wind uplift limitations apply to direct-deck underlayment systems that are not addressed in FRSA/TR1 April 2012(04-12)and are used in foam-on the applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind pressures. 5.6.4.1 Maximum Design Pressure=-45.0 pssf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional)ASTM D41 Underlayment: Tri-Built S/A HT TU Underlayment,self=adhered. 5.7 Exposure Limitations: 5.7.1 Tri-Bunt Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left exposed for longer than 30-days after installation 5.7.2 Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation. 6. iltlSTALLATiow 6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.3 Trl-Built Sand-R,SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment Qr Tri-Built Smooth HT S/A Underlayment: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 Non-Tile applications: While priming Is optional,TRI-BUILT recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. once the entire length of membrane is in place, peel-off the release flim diagonally while holding the membrane tight. Firmly roll the membrane.into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques. When installing at slopes above 8:12, Allied Building Products Corp recommends back-nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys,apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications(Tri-Built S/A HT TU Underlayment only): Reference Is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. Tile shall be loaded and staged In a manner that prevents tile slippage -and/or damage to the underiayment. Exterior Research and Design,LLC Evaluation Report A42960.10.12-R3 C00ficare of Autharizatfan#9303 FL16048•113 Revision 3:10/0812015 Page 4 of 5 i TRINITY ERD 7. BUILDING-PERMIT REQWftzmms: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. Si MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C.Rule 9N-3 CIA requirements. 9. EQUALITY ASSURANCE ENTITY: UL,LLC—QUA9625;(314)578-3406;k.chancellor@.us.uLcom END OF EVAIMATION REPORT- 1 i Exterior Research and Design,LLC- Evaluation Report A42960.10.12-R3 Certt(kote of Authorization#9503 FL26048-R3 Revision 3:10/08/2015 Page 5 of 5