Loading...
HomeMy WebLinkAboutBuilding Permit Application Aug 0817,01:35p Aultbros 7722830321 p.1 ALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date- Permit Number: ` I� Building Permit Application AUG / 8 2017 Planning and Development Services euliding and Code Regulation Division 2300 Virginia Avenue,Fart Pierce FL 34982 Phone:(772)462-1553 Fax:(772)462-1578 Commercial Residential x PERMIT APPLICATION FOR: Electrical El ,;PROPOSED IMPROVEMENT LOCATION: Address: 1630 NW Buttonbush Circle,Palm City,FL 34990 Legal Description: Harbour Ridge-Plat 19-Tallowood Village Lot 15(OR 925-332;2218-653;3493-2422) Property Tax ID#: 4426-840-0016-000-5 Lot No. Site Plan Name: Block No. Project Name: Setbacks Front Back: Right Side: Left Side: DET 'ED DESCRIPTION:.OF WORK: Remove existing and replace with new electrical distribution panel; remove and replace service lateral CONSTRUCTION INFORMATION: itiona wore to e e orme under tispermit—checka appy: 0HVAC f.Gas Tank ❑Gas Piping _Shutters ❑Windows/Doors aElectric EJ Plumbing Sprinklers O Generator Roof Roof pitch Total Sq.Ft of Construction: Sq. Ft. of First Floor: Cost of Construction:$ 1,800.00 utilities: 0Sewer 0Septic Building Height: :OWNER/LESSEE: CONTRACTOR: NameSusle M.Pawluc Name: Michael Dale Ault Address:1630 NW Buttonbush Cir Company Ault Bros, Inc.Electrical Contractor City; Palm City State:FL Address: PO Box 1528 Zip Code:34990 Fax: City: Port Salemo State:FL Phone No. Zip Code: 34992 Fax: 772-283-0321 E-Mail: Phone No. 772-283-5520 Fill in fee simple Title Holder on next page(if different E-Mail: auitbros@yahoo.com from the Owner listed above) State or County License: EC001693 If value of construction is$2500 or more,a RECORDED Notice of Commencement Is required. Cjj /i• Aug 08 17,01:35p Aultbros 7722830321 p.2 SUPPLEMENTAL CONSTRUCTION.'LIEN LAW INFORMATION: DESIGNER/ENGINEER: _Not Applicable -MORTGAGE COMPANY: Not Applicable Name: Name: Address: Address: City: State: City: State: Zip: Phone: Zip: Phone: FEE SIMPLE TrrLE HOLDER: _Not Applicable BONDING COMPANY: Not Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: I certify that no work or installation has commenced prior to the issuance of a permit. St.Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules,bylaws or and covenants that may restrict or prohibit such structure.Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will,in all respects,perform the work in accordance with the approved plans,the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exemptfrom undergoing a full concurrency review:room additions, accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory usesto another non-residential use III WARNING TO OWNER:Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property.A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing,consult with lender or an attorney before commencing work or recording our Notice of Commencement. 1 '� � 1 n' , ti771gJI r s Signature of Owner/Lessee) ontractor as Agent for Owner Signature of Contractor License HoIcTer STATE OF FLORIDAff'' STATE OF FLORIDA COUNTYOF IVQ.y1-VI COUNTYOF MA(ZV-,;, The forgoing instrurAent was acknowledged before me The forgoing instrument was acknowledged before me this--I-day of LXAJA UJ r 20 [2_.by this__? day of i.,;5'7 20 I -7 by (Y1 i[,6+a.a1 l�a.ae e If 1 I"`i C IIJ�-e-A bA-(t A712 (Name of person acknowledging) (Name of person acknowledging) (Signature of Notary Public-State of Flora) (Signature f Notary Public-State of Florida) Personally Known OR P duci i t OA "t -personally Known OR Produced Identification Type of Identification Prod `e ` i.Ut'`' aJype of Identification Produced flu:+ `amldly 1.FF 14,5ka rBATTMICHALO�:'SKI Commission No. !`��3 - i! (Sm.exPAug mmission Na.�i �y7 S 3 ` °6m ( ���pubtic,State otFla�da }+ 9 $ rtL Commission#FF 147530 _,,.. mm.expires Aug.4.201 11 Revised 07/15/2014 REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEATURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE COMPLETE INITIALS Aug 0817,01:35p Aultbros 7722830321 p.3 ELECTRICAL RISER DIAGRAM NOT TO SCALE *IJse for Tempolrary Construction Power Pole and Single Family Service Change Only. For any other electrical applications apply Florida Building Code 107.3.5 Electrical 1. Wiring;Services;Feeders&Branch Circuits;Over Current Protection;Grounding;Wiring Methods&Materials;GFCI 2. Equipment 3. Special Occupancies 4. Emergency Systems 5. Communication Systems 6. Low Voltage 7. Load Calculations 8. Design Flood ELevation Underground Overhead 1.Size Service: 200 am 2.Conductor Size: ® CU ❑ ALUM 3.a.Meter Main: b.Meter Can Only: 0 M Grounding Electrode Conductor Size ❑ #6 ® 44 ❑ #2 ❑ Other CONSTRUCTION TYPE: ® Residential El Mobile Home Dual Electrodes or Test Required ❑ New Installation ❑ Old Installation T:1b1d1b1dg_fomaslNcw ApplicationsTormsTicctrical Riser Plamdoc Rev.5129112