HomeMy WebLinkAboutProduct Approval (2) 6128/2016 Florida Building Code Online
� " &N .� � -�5,�•,`�a�} ��vs ?,,,�.�xr '� � w9 '4'�,��-, �. #,�.w�`;, .f xvd'� F�t �a�e � � '.�'�'�v��&« �- Q�f€....
-
f
HOtI{�Qe }tof BUS Home Log In User Registration Hot Topics ( Submit Surcharge Stats&Facts ! Publications j FBC Staff BCIS Site Map j Links Search y
Busiines�V1
ProductApproval
USER:PublicUser
Regulation
Product Approval Menu>Product or Application Search>Application List>Application Detail
•"FU FL# FL17188-R1
" = Application Type Revision
Code Version 2014
x Application Status Approved
FILE oFr
Comments
Archived (�?
Product Manufacturer Mid-States Asphalt&Cant Strip, Inc.
Address/Phone/Email 1637 51st Avenue
Tuscaloosa,AL 35401
(205) 345-6634
: . eric@msaroof.com
t' Authorized Signature Eric Bailey
eric@msaroof.com
Technical Representative
ar" Address/Phone/Email
Quality Assurance Representative. RECEWLED AUG 15 2017
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
i+G Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Locke Bowden
*x (� Validation Checklist- Hardcopy Received
n="
Certificate of Independence FL17188 R1 COI MSA14001.1 2014 FBC Evaluation Report- FINAL.Ddf
Referenced Standard and Year(of Standard)
Equivalence of Product Standards
Certified By `
Sections from the Code
1507.2.3
1507.3.3
1507.5.3
1507.7.3
1507.8.3
1507.9.3
httpsJ/www.floridabLilcing.org/pr/pr appdtl.aspx?param=wGEVXQwtDgvCo3EapiIIBXQg6d3dHr2xiQCvMcLMnRETMa6UFufeTw%3d%pad 1/2
6/28/2016 Florida Building Code Online
a�
'{ Product Approval Method Method 2 Option B
s✓ Date Submitted 03/31/2015
Date Validated 04/01/2015
x Date Pending FBC Approval 04/08/2015
Date Approved 06/22/2015
�i
4 4 r--s....... M. ._ --.-.- -�...---..-......-
Surroma ofRioducts
FL#
MSA Quick-Felt r.,or Name
Des ntheticlunderlayment
-Modelr' lip
17188.1
for use in steep slope roofing.
fie`¢, Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17188 R1 II MSA14001.1 2014 FBC Evaluation Report-
r Q> ` Approved for use outside HVHZ:Yes FINALDdf
abk ;> Impact Resistant: N/A Verified By: Zachary R. Priest 74021
& Design Pressure: N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
r FL17188 R1 AE MSA14001.1 2014 FBC Evaluation Report-
"� FINAL.pdf
Created by Independent Third Party:Yes
1
Contact Us:: 1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824
�r.
5
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida,::Privacy Statement::Accessibility Statement::Refund Statement
, �, Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
,� .. mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public To determine if you are a licensee underChapter
455,F.S.,please dick here.
Product Approval Accepts:
" sccuri[yatt:�rtatcs
httpsJMrww.floridabuilding.org/pr/pr appdtl.aspx?param=wGEVXQwtDgvCo3EapiIIBXQg6d3dHr2xiQCvMcLMnRETMa6UFufeTw%3d%3d 212
Certificate of Authorization
CREEK
� 17520 Edinburgh
Dr Dr
Tampa,FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT 2014 FLORIDA BUILDING CODE
Manufacturer: MID-STATES ASPHALT AND CANT STRIP, INC. Issued March 31, 2015
1637 51st Street
Tuscaloosa,AL 35401
(800)489-2391
http://www.midstatesasphalt.com
Manufacturing Plants: Nashik, India
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.2.3, 1507.3.3, 1507.5.3, 1507.7.3, 1507.8.3, 1507.9.3
Properties: Physical properties
REFERENCES
Enti Report No. Standard Year
PRI Construction Materials Technologies(TST6049) RTX-002-02-01 ICC-ES AC 188 2012
PRODUCT DESCRIPTION AND APPLICATION
MSA QUIK-FELT MSA QUIK-FELT is a woven polypropylene mechanically attached underlayment for use
in steep slope roofing as an alternative to ASTM D 226,Type I and Type ll.
Deck Type: The roof deck shall be constructed of closely fitted
plywood sheathing for new or existing construction.
Plywood deck shall be installed in accordance with
FBC requirements. Roof decks shall have no more
than 1/8 gap at abutting joints.
Min.slope: 2:12. For slopes less than 4:12,•the underlayment
must be half-lapped*a full 24" over the underlying
course.
Attachment method: Underlayment shall be attached in accordance with
the FBC requirements. At minimum, mechanically
fastened with minimum V diameter plastic cap naps
with min. 1" shank placed 12" o.c. at the side laps
and 2" from the from edge of the sheet and 24" o.c
along the along the center lines printed on the sheet.
The side laps shall be a minimum 4" wide and
minimum 12"wide at the end laps. End laps shall be
fastened 12" o.c. along the lap and 2" from the end
of the top layer.. The underlayment is installed
starting at the eave,with the length of the roll parallel
to the eave with the printed side facing up. All side
laps shall be installed to shed water from the deck.
Allowable roof coverings: Asphalt shingles, wood shakes and shingles, slate
shingles,metal roof panels and shingles
MSA14001.1 FL17188-R1 Page 1 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
MID-STATES ASPHALT AND CGREE MSA QUIK-FE T
TECHNICAL SERVICES, LLC
Cade Approved
C),Ck
Drip Edge At Rake ��'� Synthetic'
ApplieclOver : , Underlayment
Undeilayment
k, n•.✓Y i €.ii
_ , ��/ . ,fi. y`✓��i' ,# ,�' Syr 2'From Edge,
"Bxc�
` � .+ • �k / ✓ V � ,✓+'u i\0115,/`,
� v <+s � r / � �'r ��r. � � �,✓ fes`
• ,!��'4� <����'�+�� 3 -S\add ,a /���s". * �,�"��i'�"°s�� �
i Prip Edge At Eaves
as �t
.. / �:,•. Applied Directly
''� `` x ✓ r�x ^ TQ Deick
a'Top tap ,�'• i 2`End Lap
Recommended
*` Recommended
Figure 1. Installation Detail for MSA QUIK-FELT
LIMITATIONS
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Wind uplift resistance in not within scope of this evaluation.
4) Installation of the evaluated product shall comply with this report,the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) Unless otherwise stated,the minimum roof slope shall be in accordance with FBC requirements.
7) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped
in success courses installed up the deck in a manner that effectively sheds water from the deck. End laps
shall be staggered between courses in accordance with the manufacturer's application instructions.
8) The undedayment may be used as described in other current FBC product approval documents.
9) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically
fastened through the undedayment to the roof deck.
10) The underlayment shall be exposed on the roof deck for a maximum 30 days unless otherwise stated.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
MSA14001.1 FL17188-R1 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not
specifically addressed herein.