Loading...
HomeMy WebLinkAboutProduct Approval M IAM I-DARE MIAMI-DARE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315 2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy TAMKO Building Products,Inc. P.O.Box 1404 220 West 41'Street Joplin,MO 64801 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER 1 Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section(in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails,to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:TamkO ?ndeym�enter '`� e.�J ''�-J; LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there'has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 14-1117.07 and consists of pages 1 through 7. The submitted documentation was reviewed by Jorge L.Acebo. NOA No.: 17-0530.12 Expiration Date: 07/05/22 MIAMI-oane couNTY Approval Date: 07/06/17 Page 1 of 7 ROOFING COMPONENT APPROVAL Category: Roofing Sub-Category: Underlayment Material: SBS SCOPE: This approves Tamko Underlayments, as described in this Notice of Acceptance; ,designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Dimensions Test Product Description Specification TW Metal and Tile 39 3/8"wide ASTM D 1970 Self-adhering rubberized asphalt underlayment. Underlayment Manufacturing Location #1 Moisture Guard'.Plns' 36"wide ASTM D 1970 Self-adhering rubberized asphalt underlayment. M Manufacturing or r' ':Location.#1= -J39%"wide BTW Underlayment 39%"wide ASTM D 1970 Self-adhering rubberized asphalt underlayment. Manufacturing Location #2 Awabase SA 39 W wide ASTM D 1970 Self-adhering rubberized asphalt base sheet. Direct Manufacturing ASTM D 4601 adhesion to wood deck not permitted in the HVHZ. Location #1 Type II Shall only be mechanically fastened to wood deck. Do Not Remove Release Film! Awa Nailbase 39 W wide ASTM D 4601 Fiberglass rubberized asphalt base sheet. Manufacturing Type II Location #1 Tamko SA Base 39 W wide ASTM D 1970 Self-adhering rubberized asphalt base sheet. Direct Manufacturing adhesion to wood deck not permitted in the HVHZ. Location #1 Shall only be mechanically fastened to wood deck. Do Not Remove Release Film!' Tamko SA Cap 39 W wide ASTM D 6164 Self-adhering rubberized asphalt cap sheet surfaced with Manufacturing Type I granules. Location #1 Awaplan' 39 W wide ASTM D 6164 Polyester SBS modified membrane surfaced with Manufacturing Type I granules. Location #1 i NOA No.: 17-0530.12 Expiration Date: 07/05/22 MIAMI•DAD;COUNTY Approval Date: 07/06/17 Page 2 of 7 MANUFACTURING LOCATION: 1. Joplin,MO 2. Columbus,KS EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Trinity I ERD T11090.09.08 TAS 117(B)/TAS 114(C), 09/18/08 PRI Asphalt Technologies,Inc. TAP-191-02-01 ASTM D 1970 11/16/07 TAP-192-02-01 ASTM D 1970 11/13/07 TAP-193-02-01 ASTM D 1970 11/16/07 TAP-185-02-OIREV ASTM D 6164 11/06/08 TAP-1,96-02-01 ASTM D 1970 01/09/08 TAP-324-02-01 TAS 114-95 11/11/15 TAP-238-02-01 , ASTM D 4601 08/25/10 TAP-262-02-01 ASTM D 4601 01/24/12 TAP-262-02-02 ASTM D 1970 01/24/12 TAP-298-02-01 ASTM D 6164 11/10/15 TAP-366-02-01 TAS 103 (Section 19) 05/09/17 TAP-366-02-01 ASTM D1623 05/02/17 TAP-367-02-01 ASTM D1623 05/02/17 TAP-367-02-03 TAS 103 (Section 19) 05/09/17 APPROVED ASSEMBLIES: Deck Type 1: Wood,Non-insulated Deck Description: 19/32° or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened to deck,membrane adhered. Base Sheet: One or more plies of ASTM D 226 Type lI or ASTM D 2626 with a minimum 4"side lap and a 6"end lap mechanically fastened to deck with approved annular,ringshank nails and tin caps 6"o.c.at the laps and two staggered rows 12" o.c. the field of the roll. Membrane: One or more plies of TW Metal and Tile Underlayment with.a minimum 4"side lap and 6"end lap.Place the first course of membrane parallel to the eave rolling the membrane to obtain maximum contact.Remove the release liner as the membrane is applied.Vertical strapping of the roof with TW Metal and Tile Underlayment is acceptable. Surfacing: Approved Metal Roofing Assembly or Approved Roofing Assemblies where an ASTM D 1970 underlayment is allowed. NOA No.: 17-0530.12 rt�ahiI-Dane C=OUNTY Expiration Date: 07/05/22 Approval Date: 07/06/17 Page 3 of 7 Deck Type 1: Wood,Non-insulated Deck Description: 19/32° or greater plywood or wood plank System E(2): Anchor sheet mechanically fastened to deck,membrane adhered. Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4"side lap and a 6"end lap mechanically fastened to deck with approved annularringshank nails and tin caps 6"o.c. at the laps and two staggered rows 12" o.c. the field of the roll. Membrane: One or more plies of Moisture Guard Plus with a minimum 3.5"sided lap and 6"end lap. Place the first course of membrane parallel to the cave rolling the membrane to obtain maximum contact.Remove the release liner as the membrane is applied.Vertical strapping of the roof with Moisture Guard Plus is acceptable. Surfacing: Approved Roofing Assemblies where an ASTM D 1970 underlayment is allowed. Deck Type 1: Wood,Non-insulated Deck Description: 19/32" or greater plywood or wood plank System E(3): Anchor sheet mechanically fastened to deck,membrane adhered. Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626 with a minimum 4"side lap and a 6"end lap mechanically fastened to deck with approved annularringshank nails and tin caps 6"o.c. at the laps and two staggered rows 12" o.c. the field of the roll. Membrane: One or more plies of TW Underlayment with a minimum 4"side lap land 6"end lap.Place the first course of membrane parallel to the cave rolling the membrane to obtain maximum contact.Remove the release liner as the membrane is applied.Vertical strapping of the roof with TW Underlayment is acceptable. Surfacing: Approved Roofing Assemblies where an ASTM D 1970 underlayment is allowed. Deck Type 1: Wood,Non-insulated Deck Description: 19/32" or greater plywood or wood plank System E(4): Anchor sheet mechanically fastened to deck,membrane adhered. Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626 with a minimum 4"side lap and a 6"end lap mechanically fastened to deck with approved annulaf ringshank nails and tin caps 6"o.c. at the laps and two staggered rows 12" o.c. in the field,of the roll. Membrane: One or more plies of Awaplan applied at a right angle(90°)to the slope of the deck adhered in a full mopping of approved asphalt applied within the EVT range at a rate of 20-40 lbs./sq. Vertical strapping of the roof with Awaplan underlayments is-acceptable. When used in Tile roof systems the cap sheet shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum 12"o.c. at the side laps and 6" o.c. at the end laps. No nails or tin caps shall be exposed. Surfacing: Approved Mechanically Fastened or TILE BOND and/or Mortar Adhered Tile or Metal Roofing Assembly or Approved Roofing Assemblies where an ASTM D 6164 underlayment is allowed. NOA No.: 17-0530.12 Expiration Date: 07/05/22 Mwr�i nage couNry Approval Date: 07/06/17 Page 4 of 7 Deck Type 1: Wood,Non-insulated Deck Description: 19/32" or greater plywood or wood plank System E(5): Anchor sheet mechanically fastened to deck,membrane adhered., Base Sheet: One or more plies of Tamko SA Base with a minimum4"side lap and a 6"end lap mechanically fastened to deck with approved annular ringshank nails and tin caps 6" o.c. at the laps and two staggered rows 12"o.c. in the field of the roll. Shall only be mechanically fastened to wood deck.Direct adhesion to wood deck not permitted in the HVHZ.Do Not Remove Release Film! Membrane: One or more plies of Tamko SA Cap with a minimum 4"side lap and 6"end lap.Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact with base sheet. Remove the release liner as the membrane is applied. Vertical strapping of the roof with Tamko SA Cap underlayment is acceptable.I When used in Tile roof systems the cap sheet shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum 12"o.c. at the side laps and 6"o.c.at the end laps. No nails or tin caps shall be exposed Surfacing: Approved Mechanically Fastened or TILE BOND and/or Mortar Adhered Tile or Metal Roofing Assembly or Approved Roofing Assemblies where an ASTM D 6164 membrane is allowed. Deck Type 1: Wood,Non-insulated Deck Description: 19/32" or greater plywood.or wood plank System E(6): Anchor sheet mechanically fastened to deck,membrane adhered. Base Sheet: One or more plies of Awa Nailbase or Awabase SA.with a minimum 4"side lap and a 6" end lap mechanically fastened to deck with approved annular ringshank nails and tin caps 6" o.c.at the laps and three staggered rows 6" o.c.the field of the roll. Membrane: One or more plies of Tamko SA Cap with a minimum 4"side lap and 6"end lap.Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact with base sheet.Remove the release liner as the membrane is applied.Vertical strapping of the roof with Tamko SA Cap underlayment is acceptable., When used in Tile roof systems the cap sheet shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum 12"o.c. at the side laps and 6"o.c. at the end laps. No nails or tin caps shall be exposed Surfacing: Approved Mechanically Fastened or TILE BOND and/or Mortar Adhered Tile or Metal Roofing Assembly or Approved Roofing Assemblies where an'ASTM D 6164 membrane is allowed. NOA No.: 17-0530.12 Expiration Date: 07/05/22 Mi iLAM couNrir Approval Date: 07/06/17 Page 5 of 7 Tile Staging Method t; ` w I x Side View-Staged Tiles(Slope Front View-Staged Tiles(Slope 1) GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall'be in compliance with applicable building code. Tamko Underlayments shall be installed in strict compliance with applicable Building Codes. 3. All Tamko Underlayments shall be applied to a smooth, clean and dry surface with deck free of irregularities. Deck shall be fastened in strict compliance with applicable Building Codes. 4. All Tamko Underlayments shall not be applied over an existing roof membrane as a recover system but may be applied over an approved roofing Base/Anchor sheet underlayment. 5. TW Metal and Tile Underlayment,Moisture Guard Plus,TW Underlayment,Tamko SA Base&Tamko SA Cap shall not be left exposed as a temporary roof for longer than 30 days of application. 6. Awaplan shall not be left exposed asa temporary roof for longer than 180 days of application. 7. The standard maximum roof pitch for Tamko SA Cap shall be 5:12 for flat tile and profiled tiles with lugs. See E. Tile Staging/Stacking Method Above. 8. The standard maximum roof pitch for Awaplan shall be 4:12 for flat tile and profiled tiles with lugs. See Tile Staging/Stacking Method Above. 9. Tile storage shall be on a battens or toe boards when the underlayment slope limit(See#7&#8 above)is exceeded. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid_ dropping of tile directly on the underlayment. 10. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. NOA No.: 17-0530.12 a Expiration Date: 07/05/22 M"Ami.oaaE COUNTY Approval Date: 07/06/17 Page 6 of 7 i GENERAL LIMITATIONS: 11. The Tamko Underlayments may be used with any approved roof covering Notice of Acceptance listing the Tamko Underlayment as a component part of an assembly in the Notice of Acceptance. If Tamko Underlayments are not listed,a request may be made to the Authority Having Jurisdiction(AHJ)or the Miami- Dade County Product Control Section for approval provided that appropriate documentation is provided to detail compatibility of the products,wind uplift resistance, and fire testing results. 12. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose;decking,panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 13. When applying the membrane in the valley, start at the low point and work to the high point,rolling the membrane from the center outward in both directions. For ridge applications,center the membrane and roll from the center outward in both directions. 14. For the self adhered membranes roll or broom the entire membrane surface so as to have 100%contact with the base sheet,giving special attention to overlap areas. 15. Flash vent pipes, stacks,chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 16. All protrusions or drains shall be initially taped with a 6"piece of approved Tamko Underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of the same Tamko Underlayment shall be applied over the taped underlayment. 17. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 18. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city,state and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY END OF THIS ACCEPTANCE NOA No.: 17-0530.12 MIAMI-DADE C0UNURGYp=)UNTrYExpiration Date: 07/05/22 MIAMI•DADE couNTY Approval Date: 07/06/17 Page 7 of 7 � I MIAMI-DADE COUNTY MIAMI'! PRODUCT CONTROL SECTION 11.805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy GAF 1 Campus Drive Parsippany,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-DadeCounty Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Timberline HD®,Timberline®Natural Shadow®,Timberline®American Harvest®,and Fortitude"m Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a,revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA# 14-1022.20 and consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. NOA No.: 16-0811.11 MwMI•nane COUNTY Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 1 of 6 ROOFING ASSEMBLY APPROVAL Category Roofing Sub-Category: Asphalt Shingles Materials: Laminate Deck Type: Wood SCOPE This approves GAF Timberline HD®,Timberline®Natural Shadow®,Timberline American®Harvest®,and FortitudeTM Shingles as manufactured by GAF as described in this Notice of Acceptance. 9 PRODUCT DESCRIPTION Product Dimensions Test Product bescription Specifications GAF Timberline HD® 13 '/a"x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt Manufacturing roof shingle,with a laminate profile Locations#1,2,3,4,5,6,7 GAF Timberline Natural 13 1/4"x 39 3/s" TAS 110 Fiberglass reinforced heavy weight asphalt Shadow® roof shingle,with a laminate profile Manufacturing Locations#1,2,3,4,5,69 7 GAF Timberline®American 13 '/a"x 39 3/s' TAS 110 Fiberglass reinforced heavy weight asphalt Harvest® roof shingle,with a laminate profile Manufacturing Locations#2,4,59 6 GAF FortitudeTM 13 '/a'x 39 3/s" TAS 110 Fiberglass reinforced heavy weight asphalt Manufacturing roof shingle,with a laminate profile Locations#1,4 MANUFACTURING LOCATION ' 1. Tampa,FL 2. Michigan City,IN 3. Baltimore,MD a 4. Myersiown,PA 5. Ennis,TX 6. Tuscaloosa,AL 7. Dallas,TX i NOA No.: 16-0811.11 MIAMI-DAoeC0 j Expiration Date: 02/21/22 Approval Date:02/09/17 Page 2 of 6 EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date Underwriters Laboratories,LLC ASTM D3462 4787344101 07/25/16 Underwriters Laboratories,Inc. ASTM D3462 11CA48924 10/24/11 Underwriters Laboratories,Inc ASTM D3462 IOCA21994 04/22/11 Underwriters Laboratories,Inc ASTM D3462 IOCA28717 07/26/11 Underwriters Laboratories,Inc. ASTM D3462 05CA47541 11/10/06 Underwriters Laboratories,Inc. ASTM D3462 06CA31580 11/30/06 PRI Asphalt Technologies,Inc. ASTM D3462 GAF-101-02-02 11/02/05 Underwriters Laboratories,Inc. ASTM D3462 06NK05159 08/09/06 PRI Asphalt Technologies,Inc. ASTM D3462 GAF-098-02-02 11/08/05 Underwriters Laboratories,Inc. ASTM D3462 02NK41809 'd 08/11/02 Underwriters Laboratories,Inc. ASTM D3462 03NK26444 10/17/03 Center for Applied Engineering ASTM D3462 257989 05/13/97 Underwriters Laboratories,Inc. TAS 107 01NK45803 04/13/94 Underwriters Laboratories,Inc. TAS 107 06NK05159 08/09/06 Underwriters Laboratories,Inc. TAS 107 04NK04273 02/20/04 Underwriters Laboratories,Inc. TAS 107 05CA42840 11/11/05 Underwriters Laboratories,Inc. TAS 107 02NK41811 11/11/02 Underwriters Laboratories,Inc. TAS 107 03CA35209 10/17/03 Underwriters Laboratories,Inc. TAS 107 04CA13850 08/30/04 Center for Applied Engineering TAS 100 257989 04/01/97 PRI Asphalt Technologies,Inc. TAS 100 GAF-044-02-01 01/13/04 PRI Asphalt Technologies,Inc. TAS 100 GAF-098-02-01 11/08/05 PRI Asphalt Technologies,Inc. TAS 100 GAF-101-02-01 11/09/05 PRI Asphalt Technologies,Inc. TAS 100 GAF-116-02-02 03/23/06 PRI Asphalt Technologies,Inca TAS-100 ELK-083-02-01 10/16/02 ELK-084-02-01 10/15/02 ELK-085-02-01 10/14/02 ELK-086-02-01 10/24/02 ELK-087-02-01 10/21/02 ELK-088-02-01 10/16/02 ELK-107=02-01 10/09/03 ELK-108=02-01 10/09/03 1 ELK-109-02-01 10/09/03 'LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. IAMI•DADE COUNTY NOA No.: 16-0811.11 M Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 3 of 6 INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.I' 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide,clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail W,attached. 5. Nailing shall be in compliance with Detail W,attached. LABELING Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. QMIAMI-DADE COUNTY BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. { 'i NOA No.: 16-0811.11 MIArn•DADE COUNTY Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 4 of 6 DETAIL A COURSE LAYOUT i DECK FULL 5th 17" OFF 4th 11" OFF 3rd 6" OFF 2nd FULL 1st NOA No.: 16-0811.11 MIAMI- Ane COUNTY Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 5 of 6 1 d ,I DETAIL B OVERALL DIMENSIONS AND NAILING PATTERN j 39-3/8" 14-1(36-17-1 2" 14-1(363-"17A/2" m)2„ { (368-445mm 6-1/2"-9-1/2" 6-1%2"-9-1/2`' ail guide line 13-1/4" (165-2411 (165-241-) 5-3/4"-6-1/4" 337mm � (146mm-159mm) ( ) 112"_2-T/27- _; -� �- ♦— from bottom of shingle (13-64 i elf seal adhesive 9 on back ENHANCED NAILING PATTERN - six nails per shingle*, required by some local codes and required for enhanced wind coverage on certain products. See limited warranty for details. ' j I These shingles MUST be nailed a nominal 6" (152mm)from bottom of of shingle, above the cut outs, as shown. Nails must not be exposed. END OF THIS ACCEPTANCE 1 ' I 1 I I � I I NOA No.:16-0811.11 MIAMI•DADE COUNTY Expiration Date:02/21/22 Approval Date:02/09/17 Page 6 of 6 {