Loading...
HomeMy WebLinkAboutProduct Approval fiAUG PERF AIT TiNG St. Lucie County, Fl- PRODUCT APPROVAL NUMBER: FL #16736.2 OPENING IDENTIFICATIONS- I . HS 2. HS 3, HS 962016 Florida Building Code Online 5t t r BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts I Publications FBC Staff I SCIS Site Map I Links I Search I i loridr G 17f;.!I Product Approval CI — USER:Public User loft�ttaytm Product Approval Menu>Product or Aoolication Search>Aoplicatlon List>Application Detail FL# FL16736-R1 Application Type Revision AUG Code Version 2014 Application Status Approved P E R."A I TT Jf q St. Lucie(founts, i=L Comments Archived D Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenue Ocala, FL 34474 (352) 368-6922 Ext 255 sbrooks@cws.cc Authorized Signature Stephen Brooks sbrooks@cws.cc Technical Representative Erin Koss Address/Phone/Email 1900 SW 44th Ave. Ocala, FL 34474 (352) 368-6922 Ext 291 ekoss@cws.cc Quality Assurance Representative Jay Lathrop Address/Phone/Email 1900 SW 44th Ave. Ocala, FL 34474 (352) 368-6922 Ext 291 jlathrop@cws.cc Category Windows Subcategory Horizontal Slider Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer O Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lucas A.Turner the Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 07/21/2020 Validated By Steven M. Urich, PE 1*6 Validation Checklist- Hardcopy Received Certificate of Independence FL16736 R1 COI EvalRep CWS-8718(HS-8200. 74x63. IMP).pdf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA/101/I.S.2/A440-08 2008 ASTM E1300-04 2004 ASTM E1886-05 2005 ASTM E1996-09 2009 PA/TAS 201/202/203 1994 Equivalence of Product Standards https:/Avww.floridabuilding.orgfpr/pr app dU.aspx?param=wGEVXQwtDquBoblp/o2flZm6TgPohLz6ontOaKpvglON3eNaBBBv3yAgMA%3d%3d 1/2 9/5/2016 Florida Building Code Online Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/15/2015 Date Validated 04/21/2015 Date Pending FBC Approval 04/25/2015 Date Approved 06/22/2015 Summary of Products FL# Model,Number or Name Description 16736.1 HS-8200 PVC Horizontal Slider HS-8200 PVC Horizontal Slider, IMPACT, 74"x 63",XO or OX. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16736 R1 II CWS-8718 (HS-8200, 74x63, IMP).Ddf Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: +60/-60 Evaluation Reports Other: Large Missile, 74"x 63", DP+/- 60 psf. Outer lite in FL16736 R1 AE DuPont PVB NOA 13-0129 27.Ddf I.G. must be safety glazed when used above 30 ft. in HVHZ. FL16736 R1 AE EvaIReD CWS-8718 (HS-8200, 74x63, Glass complies to ASTM E1300-04. IMP). df FL16736 R1 AE Ouanex (Mikron) NOA 12-1017 02.Ddf Created by Independent Third Party: Yes 16736.2 HS-8200 PVC Horizontal Slider HS-8200 PVC Horizontal Slider, IMPACT, 111"x 63", XOX. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16736 R1 II CWS-8698 (HS-8200 111x63, IMP).Ddf Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: +60/-60 Evaluation Reports Other: Large Missile, 111"x 63", DP+/- 60 psf. Outer lite in FL16736 R1 AE DuPont PVB NOA 13-0129 27.Ddf I.G. must be safety glazed when used above 30 ft. in HVHZ. FL16736 R1 AE DuPont SGP NOA 11-0624 02.Ddf Glass complies to ASTM E1300-04. FL16736 R1 AE EvaIReD CWS-869B (HS-8200, 111x63, IMP df FL16736 R1 AE Ouanex (Mikron) NOA 12-1017 02.Ddf Created by Independent Third Party: Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. :: Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® N M Credit Card j Safe F https://www.floridabuilding.orglpr/pr_app dfl.aspx?param=wGEVXQwtDqu8obl%2FlZm6TgPohlz6ont0aKpvglON3eNaBBBv3yAgMA%3d%3d 212 URNER 1239 Jabara Ave. North Port,FL 34288 ENGINEERING & Ph. 941-380-1574 TCONSULTING, INC. FBPE C.O.A. #29779 Evaluation Report 869B April 18,2015 Product Description: Series 8200 PVC Horizontal Slider Window,Large Missile Impact(HVHZ), XOX 111"x63"unit size with design pressures of+/-60 psf(Fin or Flange window) Manufacturer: Custom Window Systems,Inc. 1900 SW 44`x'Ave, Ocala,FL 34474 Statement of Compliance: This report evaluates the above-listed product per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of the 5t' Edition(2014)Florida Building Code including the High Velocity Hurricane Zone. The product testing standards performed are outlined below. Technical Documentation: 1) This report,prepared by Lucas A.Turner,P.E., at 1239 Jabara Ave.,North Port,FL 2) Approval drawing CWS-869B, signed and sealed by Lucas A. Turner,P.E. 3) Test Reports NCTL-210-3887-3, -3A, -4, and -4A,by National Certified Testing Laboratories, Orlando,FL, signed and sealed by Gerard J.Ferrara,with testing performed: TAS 201,202,203 `94,ASTM E 1886 '02/04/05,ASTM E 1996 '04/06/09, and AAMA/WDMA/CSA 101/I.S.2/A440 `08 4) Supplemental Calculations to support CWS-869B, signed and sealed by Lucas A.Turner,P.E. Installation: Units must be installed according to approval document CWS-869B. Limitations of Use: This product: • May be used up to the sizes and daylight openings indicated in CWS-869B • Achieves design pressures of+/-60 psf • Is Large Missile impact resistant and does not require the use of shutters • May be used in the High Velocity Hurricane Zone • In the operable sash, requires Dupont Butacite PVB Interlayer per Miami-Dade N.O.A. 13- 0129.271, and in the fixed glass requires Dupont SentryGlas Interlayer per Miami-Dade N.O.A. 11-0624.021 • Requires Quanex(Mikron)white rigid PVC framing per Miami-Dade N.O.A. 12-1017.021 1 I have evaluated the interlayer and framing materials in these Dupont and Quanex NOAs and find that they comply with the requirements of the 5f'Ed. (2014)Florida Building Code for use in this product. Certification of Independence: I do not have,nor do I intend to acquire,nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have,nor do I intend to acquire,nor will I acquire,a financial interest in any other entity involved in the testing or approval process of this product. `ollIMrpr1 •' CSN --J No 58201 4/18/2015 s TAIT OF *� Lucas A. Turner, P.E. FL PE#58201 *tO/ONA S�4T+'i Lucas A. Turner 2015-04-18 RAL NOTES: w HORIZONTAL SLIDER - LARGE MISSILE IMPACT 1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED SYs1rEPNSTO COMPLY WITH THE FLORIDA BUILDING CODE(FBC),CURRENTEDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVIT AND ;INDWOW 00S44TH AVE. IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED ALA,FLORIDA 34474 IN ASTM E 1996 PER THE FBC. WWW.CWS.CC 2.GLAZI 8200 PVC 3.CONFIGURATIONS:"OX","XO". HORZ.SLIDER 1121/4"MAX.OVERALL FLANGE WIDTH 4.DESIGN PRESSURE RATING: IMPACT -NEGATIVE DESIGN LOADS BASED ON,TESTED PRESSURE AND 111"MAX.UNIT WIDTH GLASS TABLES ASTM E-1300-04. -POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE,WATER �n a INFILTRATION TEST PRESSURE AND GLASS TABLES 4915116" 24 5/8° ASTM E-1300-04. o CD IW- GLASS DLO GLASS DLO o o 5.ANCHORAGE:THE 33 1/3%STRESS INCREASE HAS NOT BEEN USED p } -- -- - -- - -- DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD w ¢ m ANCHOR CALCULATIONS. rn U Z 641/4° I I 1 I 6.PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT MAX. I I REQUIRED. THE IMPACT ROTARY LOCKS ARE INTENDED TO BE LEFT o C/) OVERALL UNLATCHED DURING NORMAL OPERATION OF THIS PRODUCT,BUT $ w Z W FLANGE MUST BE ENGAGED PRIOR TO EXPOSURE TO HURRICANE WINDS AND W o Q m HEIGHT B B FLYING DEBRIS. w w H ww w m w OC MAX. 5813/16' 7.ALL FRAMES AND VENTS FULLY WELDED.SMALL JOINT SEAM SEALANT < z 0 i �/ O I �/ I USED AT FIXED MEETING RAIL AND HEAD/SILL. o a UNIT /� GLASS /� 561/4" a = W HEIGHT DLO I 1 D I D GLASS U D B DLO 8.SERIES/MODEL DESIGNATION HS-8200. m ¢ z s 59 9/16" 9.THE DESIGNATION XAND O STAND FOR THE FOLLOWING: tltNulttt, SMAXASH I e X=OPERABLE SASH,O=FIXED SASH `,,,`%0P4DREW TGO�i HEIGHT I 10.SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR �� P. \O E ryS•'•.P 'i I I I D LOCATION. �JG:• 'ycn�: I a s •: No 58201 C 11.EXTERNAL W EEP SLOT=1/4"x 1"LOCATED 4"FROM BOTH ENDS. A C fJ A 2715/16" MAX.SASH WIDTH 6 Lucas A. Oj�Att�� Turner IM it 2015-04-11 Z 15:17-04:00 4/11/2015 LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: GENERAL NOTES AND TABLE OF CONTENTS ELEVATIONS DRAWN BY: DATE: GENERAL NOTES&ELEVATIONS...........1 GLAZING DETAILS.....................................2 TEF 10/11/13 SECTION VIEWS&GLAZING DETAILS....' MAX. UNIT SIZE DESIGN PRESSURE RATING IMPACT RATING DWG#: EXTRUSIONS&B.O.M...............................4 CWS-869 B ANCHOR SCHEDULE&NOTES................5 111' x 63 +/- 60 PSF LARGE MISSILE IMPACT INSTALLATION DETAILS...........................6 SCALE: SHEET 1:20 1 OF6 aaom.ffl WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA,FLORIDA 34474 www.cwS.cc 8200 PVC 7/8"OVERALL HORZ.SLIDER 3/16"ANNEALED OR TEMPEREDIMPACT 7/8"OVERALL 1/4"AIRSPACE 1/8"ANNEALED OR TEMPERED �n v 7/16°LAMI3/8"AIRSPACE o o H 3/16"ANNEALED 5/16"LAMI c c .090 SENTRY GLASS IONOPLAST INTERLAYER 1/8"ANNEALED } W Q m 3/16"ANNEALED .090 DUPONT PVB INTERLAYER U) U Z 1/8"ANNEALED 9 PURFECT GLAZE"H" m SIKAFLEX 552 p N W Z W PURFECT GLAZE°H" a w 0 9 SIKAFLEX 552 p2: d 11 1/2"GLASS BITE r CW7 U V) 30 y = W Q O 11 1/2"GLASS BITE p U 30 ca *{{{{Ilflffll 1s ,��``PS40REW T�ii 14 � � 0 ��.`GQS.��GENSFG,Qy�,. 1 0E70(� v: No 58201 9 STATE OF 0 GLASS TYPE B : � O c4 p R LOQ "9/ONAI GLASS TYPE A FIXED GLASS 4/11/2015 LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: GLAZING DETAILS DRAWN BY: DATE: TEF 10/11/13 DWG#: REV,: CWS-869 B SCALE: SHEET 1:1 20F6 INTERIOR22 5 3 4 WINDOW SYSTEMS 1900 SW 44TH AVE. 1 2 19 or 49 0 15 1 13 4 45 43 OCALA,FLORIDA 34474 W W W.CWS.CC OQ O 40 �gO 8200 PVC HORZ.SLIDER IMPACT Qoo r o � � w oo � 11 e 3 2 5 6 1 18 8 1 SECTION VIEW D-D o 0 0 JAMB ROTARY LOCKS Y w JAMB ROTARY LOCKS: w ¢ m O 40 MAY BE SUBSTITUTED FOR JAMB rn SECTION VIEW B-BIMPACT LOCKS ON FLANGE UNITS. LL O t REQUIRED ON FIN UNITS. a o mod 45 $ W Z W 43 a w D a cr O 46 W U U 31 .37 () o zW 18 LrJ� 44 U o 16 m ¢ Z 11 I 50 14 ,llll{Illllll,� HEAD IMPACT HOOK(TYP.) �����Pt`10RE W T►p- MIDSPAN OF(ITEMS44&46)SASHES ,`��GQS•��CENS G,peeo' 28 JJ: tn: No 58201 INTERIOR %o' ;aCZ "P STATE OF :�� iii C� • 4.0 R%D• JAMB IMPACT HOOKS(ITEM 42) OR ROTARY LOCKS(ITEM 23) 14 LOCATED AT THIRD POINTS.NOTES: 16 4/11/2015 6 7 EITHER IMPACT HOOKS OR ROTARY LOCKS LUCAS A.TURNER,P.E. 18 MUST BE USED IN BOTH JAMBS OF FLANGE UNITS. FL PE#58201 ONLY ROTARY 9 7 O JAMBS OF FN UNITS. MUST BE USED IN BOTH 1239 JABARA AVE. NORTH PORT,FL 34288 4 a o I 74 I SHEET DESCRIPTION: 10 <= SECTION VIEWS t U U li DRAWN BY: DATE: SECTION VIEW A-A HEAD IMPACT HOOK AND TEF 10/11/13 JAMB IMPACT HOOK/ROTARY LOCK LOCATIONS DWG#: REV.: 1:20 CWS-869 B SECTION VIEW C-C SCALE: ALTERNATE FIN FRAME SHEET 12 3OF6 PARTS LIST 31/8— CORNER CONSTRUCTION ITEM PART#IDESCRIPTION VENDOR MATERIAL 31/8" 1 H-6049 IMain Frame,SH/HS,Flange,PVC Mikron PVC 31/8" WINDOW SYSTEMS 2 H-1681 Fixed Rail,Heavy Duty,Aluminum Keymark Alum 1 42 1900 SW 44TH AVE. 3 S-6077 Cover,HD Fixed Rail,PVC Mikron PVC 1/16" OCALA,FLORIDA 34474 5 P-4638 #8 x 2 1/2"Ph Mod Truss Type A TE Ajax Steel 211/16" 1/16" 3 9/16" u 17/8" 1/16" W WW.CWS.CC 6 P-3342 Seam Sealer,SM-5504 Schnee Silicone t° CORNER WELD 7 S-1776 Roller Track Keymark Alum (ALL SIDES) 8200 PVC II 1:8 8 S-6013 Screen Adapter,Jamb,PVC Mikron PVC HORZ.SLIDER 9 S-6014 IScreen Adapter,Head&Sill,PVC Mikron PVC PVC FRAME FLANGE-6049 PVC FRAME FIN-6048 HD MTG RAIL-1681 IMPACT 10 P-4479 Weep Co1,er w/Flap M&M Nylon 6 11 S-6064 Glazing Bead Mikron PVC �2 v 1 15/16" 1 3/16"-{ 5 12 H-6050 Sash Meeting Rail,PVC Mikron PVC I —23/16" T-� I 23/16" - w 13 H-6051 Sash Pull Rail,PVC Mikron PVC 12 I I 14 3 13 0 0 O 14 H-6052 Sash Top/Bot.Rail,PVC Mikron PVC t 5!8" 1 5/8" q 1 1516, � w } 15 H-1497 Reinf.Sash Meet.Rail Keymark Alum 1/16" 2 u! ¢ m 1/16" 1/16" 1116" L 16 H-1498 lReinforcement,Sash,Side Rail Keymark Alum Z 17 H-1699 lReinforcement,Sash Pull Rail Keymark Alum PVC SASH MTG.RAIL-6050 PVC SASH SIDE RAIL-6051 PVC SASH TOP/BTM RAIL-6052 PVC HD MTG RAIL COVER-6077 FIXED MEETING RAIL O 18 P-3429 Wst .,0.270 X.187 back FinSeal,Grc Ultrafab �3/16' SCREWED TOGETHER WITH U) 19 P-3783 Lock,Impact,PVC Interlock OUTERFRAME $ ( z Il 1:8w o O Or 20 P-4051 #8 x 1 1/4"Ph Flat Tek,Wht. Fastenal Steel O a w F- ez 21 P-4069 Keeper,Impact,PVC Interlock 5/8" w Lu cc 22 P-3539 #8 x 3/4"Square PH Tek,Wht. Fastenal Steel 6" I 3/a 1 —"� o ¢ w 23 P-4958 Rotary Lock Interlock 1 5/16° 46 1„ 1/16 15/16^ �. 1/16 j a: m 24 P-4633 8-32 x 1/2"Barrel Fastener Interlock 7/6' L ll�� m ¢ O 25 P-4952 Keeper,Rotary Lock Interlock � L1/16" SASH MTG.RAIL-1497 Z SASH REINF.-1699 t��1r��upr 26 P-4779 Roller,Tandem M&M Nylon PLAN VIEW-1999 HEAD IMPACT HOOK-1999 27 P-3541 #8 x 1/2"Quad PH TEK 2 Zinc Fastenal Steel 3/4"S6 �•� `�•• CEN G r. 3/16" 3/16" r 7/16° 28 GLASS SEE SHEET 2 CARDINAL GLASS J;' • cn rr 29 Purfect Glaze"H"or Sikaflex 552 Henkel/Sika Silicone O r 16 7 �: No 58201 :� 30 P-3028 Set.Blk.,85 Dur.,1/8"x 7/8"x 2"Lg. Frank Lowe Rubber 6" I i 1!168 1/16" *' 5!8"r- S.B.RJS.S.R.-1498 31 P-3218 Screen Frame Allmetal ROIIForm T- ri}- X44 ROLLER TRACK-1776 '9: STATE OF 32 P-4754 Screen Comer Key Allmetal Nylon 5JL 1/16" 1/4^ rrir�'%'.A' O R I...- 1/4" 33 P-4755 Screen Comer Key w/Safety Tab Allmetal Nylon PLAN VIEW-2000 PANEL IMPACT CATCH-2000 11 718"'1 ,r�V 34 P-3029 Screen Pull tab Summit 7!6^ I «�r�rJ111''' 35 P-3033 Screen Spring Fla.Spring SS 0 3116" �— 9/16 36 P-3228 Screen Spline Dapa O PVC GLAZEBEAD-6064 L 1/16" 4/11/2015 37 P-4772 Screen Cloth,Fiberglass GLAZE BEAD-1112 LUCAS A.TURNER,P.E. 40 P-3113 Screw Support,PVC Team Plastics Rubber I f � 112"11/8.1 FL PE#58201 41 P-3752 Cap Plug,1/2"Hole M&M Nylon 1 5/16" ���I 316°�,II--1 5/16"-{ 1239 JABARA AVE. - I NORTH PORT,FL 34288 42 S-1577 Impact Hook,Frame,Jamb Keymark Alum 42 1/16 48 PH.941-380-1574 43 S-1112 Reinforcement,Head,Jamb Keymark Alum 7/6 1/16" 1/16^ Y � PVC SCREEN CATCH-6013 SHEET DESCRIPTION: 44 S-2000 Impact Channel,Sash Keymark Alum PLAN VIEW-1577PVC ANTI-LIFT-6005 ALUM SASH IMPACT HOOK-1577 45 P-3748 #6X5/8 Ph FH TEK,Zinc,Painted Ajax Steel 1 1/e"-j 46 S-1999 Impact Hook,Frame,Head Keymark Alum 3/16"�I- 3' -{ �1/2" 5/16' BOM AND EXTRUSIONS 47 H-6048 Main Frame,SH/HS,Fn,PVC Mikron PVC I I 9 DRAWN BY: DATE: r ao 1/16" TEF 10/11/13 48 S-6055 Roller Track,PVC,(Anti-lift) Mikron PVC SCREW SUPPORT-3113 PVC SCREEN SUPPORT-6014 DWG#: 49 P-5250 Lock,Impact,PVC,w/Flipper Interlock CWS-869 B 50 P-4730 1#8 x 1/2"Ph Mod Truss TEK FastenalSteel LINE ITEMS NOT USED: SCALE: SHEET 14,38-39 NOTE:ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. 1:2 40F6 � VdIfiIDOVV SYSTEMS T(TYP.) 1900 SW 44TH AVE. 6'MAX.(NP.) 3"(TYP.)—�{ r 16 1/4"-{ SEE NOTE 2 4"MAX.(TYP.) 8"MAX.O.C.(TYP.) WWW.OCALAFLORIDA 34474 MAX O.C. W W W.CW S.CC 6'MAX.(fYP.) I (NP,) I 4'MAX.(NP.) INSTALLATION 8200 PVC ANCHOR(TYP.) HORZ.SLIDER O.C. IMPACT I i i i MAXMi i i I (NP.) 17"MAXT P O.C. X O X X O XLi 0 0 C3 �c; w .. 0 wZw ANCHOR LAYOUT-(FIN) a °w p w ANCHOR LAYOUT-(FLANGE) ❑ ❑ D- w cc U U W 7 U m Q Z P:�.CENs�.tip�:�� v tNo 58201 '.7� NOTES: ��� STATE OF 1.INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION.SILL ANCHOR SPACING SAME AS HEAD. �'cCss�O R 1 Q G,��� �i10 fONA�{E�1_0 2.SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16"IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED. 3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 6. 4/11/2015 LUCAS A.TURNER,P.E. 4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST FL PE#58201 BE PROTECTED TO PREVENT REACTION. 1239 JABARA AVE. 5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM NORTH PORT, 34288 SPECIFIED IN TABLE 1,SHEET 6, PH.941-380--11 574 SHEET DESCRIPTION: 6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE. ANCHOR SCHEDULE AND INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT DO NOT REQURE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. NOTES INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. DRAWN BY: DATE: 7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:3"FOR MASONRY,1"FOR WOOD AND METAL. TEF 10/11/13 8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. DWG#: REV.: SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. CWS-869 B 9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: SCALE: SHEET FMA/AAMA 100(FIN WINDOWS),FMA/AAMA 200(FLANGE WINDOWS), FMA/WDMA 250(BOX WINDOWS),FMA/AAMA(WDMA 300(E)CTERIOR DOORS) 1:25 5 OF 6 MIN.EMBEDMENT // f]/7 gogX/•L/a{/� TYPICAL HEAD ANCHORAGE SEE TABLE 1 SUBSTRATE V� Ly(!dy U(l LY I(1]/�/I BY OTHERS WINDOW SYSTEMS MIN.EDGE DIST. 1/4"MAX.SHIM SEE TABLE 1 MIN.EDGE DIST. SUBSTRATE SEE TABLE 1 SEE TABLE 1 BY OTHERS 1900 SW 44TH AVE. SUBSTRATE BY OTHERS 1/4"MAX.SHIM SEE TABLE 1 wWW.OCALAFLORIDA 34474 W W W.CW S.CC SEE TABLE 1 MIN.EDGE DIST. MIN.EMBEDMENT c'O SEE TABLE 1 PERIMETER SEALANT SEE TABLE 1 8200 PVC BYINSTALLER INSTALLATION ANCHOR INSIDE AND OUT (� SEE TABLE 1 (l HORZ.SLIDER SEALANT BEHIND IJ SEE TABLEDMENT IMPACT FLANGE BY INSTALLER 1/4"MAX.SHIM a 0 Qo PERIMETER SEALANT a PERIMETER SEALANT BY INSTALLER o o BY INSTALLER p��� INSIDE AND OUT INSIDE AND OUT INSTALLATION ANCHOR � �. INSTALLATION ANCHOR SEALANT BEHIND SEE TABLE 1 W ¢ m FLANGE BY INSTALLER SEALANT BEHIND SEE TABLE 1 FIN BY INSTALLER v Z HORIZONTAL SECTION / C� HORIZONTAL SECTION O 6 TYPICAL JAMB ANCHORAGE \,S TYPICAL FIN ANCHORAGE o HEAD AND SILL SIMILAR FOR FIN INSTALLATION N W Z W p W W lUl ao w uJc� U 1/4"MAX.SHIM a = W SEALANT BEHIND oQ U ❑ FLANGE BY INSTALLER (~70 U 1-H Z PERIMETER SEALANTt1191110l+ INSIDE AND OUT NSTALLER SEE TABLEDMENT ����,`�,P}'�E N..'f TL��''� ��GP•V� 3�p•'Zj No 58201 SUBSTRATE BY OTHERS SEE TABLE 1 MIN.EDGE DIST. =ro. it. SEE TABLE 1 TV/// �' 4. STATE OF ,41-- A VERTICALSECTION %0 lVQ 6 TYPICAL SILL ANCHORAGE � F�oo04/�2TABLE I:APPROVED INSTALLATION FASTENERS E DIST. LUCAS A.TURNER,P.E. FLANGE CONCRETE(2.0 KSI MIN.) 3/16"ITW TAPCON 1-1/2" 1-1/8" 39 A#58201 PERIMETER SEALANT 1239 JABARA AVE. FLA BY INSTALLER NORTH PORT,FL 34288 FLANGE CONCRETE(2.85 KSI MIN.) 3/16"ELCO ULTRACON 1" 1" INSIDE AND OUT PH.941-380-1574 HORIZONTAL SECTION FLANGE GROUT-FILLED CMU(ASTM C-90) 3/16"ELCO ULTRACON 1-1/4" 2-1/2" 6 BOX FRAME INSTALLATION SHEET DESCRIPTION: FLANGE 2X MIN.SOUTHERN PINE(G=0.55) 3/16"FFW TAPCON 1-3/8" 7/8" HEAD AND SILL SIMILAR FOR BOX INSTALLATION INSTALLATION DETAILS OR ELCO ULTRACON FLANGE 2X MIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-3/8" 7/8" FLANGE REMOVAL NOTE:PARTIALLY OR FULLY REMOVING THE FLANGE, 16 GAUGE(0.060")MIN.STEEL STUD #10-16 HILTI KWIK-FLEXOR ITW FULL THREAD UP TO AND INCLUDING A BOX-FRAME APPLICATION IS ACCEPTABLE PROVIDED: DRAWN E DATE: FLANGE 7/16" TEF 10/11/13 (33 KSI YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.060" MIN.1/4"FILLET OF CONSTRUCTION-GRADE ADHESIVE CAULK IS APPLIED DWG#: REV.: FLANGE 1/8"ALUM.(6063-T5 MIN.)OR #10 GRADE 5 SELF-TAPPING/ FULL THREAD 7/16" INSIDE AND OUT,FULL PERIMETER,BY INSTALLER. 1/8"STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125" PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS CWS-869 B FIN 2X MIN.SOUTHERN PINE(G=0.55) #8 WOOD SCREW 1/2" SHOWN FOR FLANGE WINDOWS. SCALE' SHEET 1:2 6OF6