HomeMy WebLinkAboutDrawing -----------------
36" X 80"
1
REPLACE DOOR IN 1 OPENING ONLY.
LESS THAN 25%OF TOTAL GLAZED AREA TO BE REPLACED UNDER THIS PERMIT.SHUTTERS
NOT REQUIRED PER FBC,5TH EDITION(2014), EXISTING BUILDINGS,706.4,EXCEPTION#2.
OPENING PRODUCT DESIGN
OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS
NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG.
1 36 80 20.00 1 4 36.1 1 -39.3 FL8228.8 55.0 1 -55.0 FRONT ENTRY-LSMI
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 3/16"TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT= 12 FT 6 IN
MYERS RESIDENCE
3548 SEMINOLE ROAD DOOR REPLACEMENT PLAN
FORT PIERCE, FLORIDA