Loading...
HomeMy WebLinkAboutBUILDING PERMIT APPLICATIONALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: 08/29/2017 Permit Number: Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax; (772) 462-1578 Commercial Residential V PERMIT APPLICATION FOR: To Select from dropbox, click arrow at the end of line PROPOSED IMPROVEMENT LOCATION-,',— OCATION:'•"Address: Address:9940 S OCEAN DR 1105 - JENSEN BEACH, FL 34957 Legal Description: OCEANA OCEANFRONT CONDOMINIUM ONE APT 1105 AND .7120 PERCENT INTIN COMMON ELEMENTS (OR 660.867). Property Tax ID [t: 4502-502-0112-000-2 Lot No. Site Plan Name: Block No. Project Name: WATER HEATER TANK REPLACEMENT Setbacks Front Back: Right Side: Left Side: ......... . DETAILED DESCRIPTION OF WORK: i REPLACE FAILED ELECTRIC WATER HEATER TANK LOCATED UNDER A/C HANDLER INSIDE HALL CLOSET WITHIN CONDOMINIUM UNIT WITH A NEW 30 GALLON AO SMITH ELECTRIC WATER HEATER. UC A N INFORMATION: itiona workto e e Orme un ert is permit—c ec a appy: ❑HVAC [Gas Tank ❑Gas Piping Shutters ❑Windows/Doors 11 Electric 21 Plumbing ❑Sprinklers I�I Generator Roof Roofpitch Total Sq. Ft of Construction: SFt. of First Floor: Cost of Construction:$ 1400.00 Utilities:11 Sewer 11 Septic Building Height: c Name Stephen J. Borkowski Name: Robert W. Ludlum Addres0940 S Ocean Dr Apt 1105 Com an Benjamin Franklin Plumbing Company: Y City: Jensen Beach State:FL Address: 1631 SW South Macedo Blvd City: Port St. Lucie State: FL Zip Code: 34957 Fax: n/a Phone NO 772-229-0382 Zip Code: 34984 Fax: 772-871-9069 E -Mail: Na Phone No. 772-671-9494 Fill in fee simple Title Holder on next page ( if different E -Mail: Permits@benfmnklinplumber.com State or County License: CFC1426801 from the Owner listed above( If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. SUPPLE M P,TALCONSTRUCTION LIEN LAW INFORMATION: DESIGNER ENGINEER: Not Applicable Name: sieGlen J. aun<ow is MORTGAGE COMPANY: Name: Ho6enw. warm Not Applicable Address: 99905OCEAN OR 1105-JENSEN 3EACH,FL36959 Address: 9940So nDr APM05 fore me this dayo Thef4rgging lnstr ent wa oMUM City: Jonaeneoem State: _ Zip: Phone City: PodStAude Zip: Phone: State:_ FEE SIMPLE TITLE HOLDER: _ Not Applicable Name: BONDING COMPANY: Name: _Not Applicable Address:1631 sw sout Maceuo BW Address: Type of Identification City: City: -A 110M.. Zip: Phone: Zip: Phone: Signature of Nota _a 'c5 heGdlPAar.4EddN#GGOBBaSB OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie Counts makes no representation that is granting a Permit will authorize the permit holder to build the subject structure which is in can lict with an v applicable Home Owners Assoc ation rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult nder or an aytorney before commencine work or recordinaftur Notice of Commencement. fl1/ 10, / SI of ner/Les ontractor as Agent for Owner Sign re of ontra torr nae Holder ORID/Vi/. STATEOCIF COUNTVOF01 ��(� �` L� COUNTY OF (1ClSFY/ fore me this dayo Thef4rgging lnstr ent wa oMUM Theing instru tw sac owledge efore me this day_of by �y / �20 NaaamY,9e of per; P rnadng statement Name of perso haking statement Personally Known ✓ OR Produced Identification Personally Known V OR Produced Identification _ Type of Identification Type of Identification P uced Prod eds/,�� -A 110M.. Y'� L HERNANDEZ (Si ature of Not L?: IiC'Sfpj6; 119dmNa GG088a99 Signature of Nota _a 'c5 heGdlPAar.4EddN#GGOBBaSB r RES January 28, 2021 ES January 26.2021 Commission No. (Seal) Commission No. (Seal REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TU RTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED Nev. a/41r Co Smith, Residential Electric Water Heaters ENHANCED HEATING ELEMENTS CODE COMPLIANCE • Dual 4500 watt elements for fast recovery • Meets URC and ICC National Codes and and reliable operation.* listed with CEC. • Incoloy stainless steel lower element lasts • Complies with the Federal Energy longer than a standard copper element. Conservation Standards effective DYNACLEAN" DIFFUSER DIP TUBE April 16, 2015, in accordance with the Energy Policy and Conservation Act • Helps reduce lime and sediment buildup (EPCA), as amended. and maximizes hot water output. Made from long-lasting PEX cross-linked polymer. HIGH ENERGY FACTORS • Eco -friendly nom -CFC foam insulation, heat traps and other features combine to yield a higher Energy Factor that maximizes savings on operating costs. COREGARD'" ANODE ROD • Our anode rods have a stainless steel core that extends the life of the anode rad allowing superior tank protection far longer than standard anode rods. BLUE DIAMOND- GLASS COATING • Provides superior corrosion resistance compared to industry standard glass lining. ENHANCED -FLOW BRASS DRAIN VALVE • Our residential water heaters have a solid brass, tamper resistant, enhanced -flow, ball type, drain valve. • Uses a standard female hose fitting that allows for fast and easy draining during maintenance. • Designed for easy operation, this valve includes an integral screwdriver slot that features a''/a turn (open/close) radius, which not only permits full straight through water flow but also a quick and positive shut off. 'Madel ENL zo nu a single element. APPROVED FOR MANUFACTURED HOUSING • All residential electric water heaters are compliant with HUD Standards for mobile homes/manufactured housing. CERTIFIED TO UL 174 FOR HOUSEHOLD ELECTRIC WATER HEATERS CSA CERTIFIED AND ASME RATED T&P RELIEF VALVE DESIGN -LISTED BY UNDERWRITERS LABORATORIES • Certified at 300 psi test pressure and 150 psi working pressure. • Listed according to UL 174 standards governing storage tank type electric water heaters. 6 -YEAR LIMITED TANK AND PARTS WARRANTY • For complete information, consult written warranty or go to hotwateccom. D kbrvary 2016 A.O. Simms Cmporalmn. All rotor ... wa —hertsnlerl 1900.5371953 Tolll USA I A. 0. Smith Corporation 1500 Tennessee waltz Parkway IAshland CM. TN 37015 PERMIT SUBMITTAL DOCUMENTS Page 1012 AOSRES0602 ToSmithrad Residential Electric Water Heaters Model Number Ga11on Capaciry First Hour Rat Gallon ,,,In Energy Factor Recovery @ 90°F Rlse GaN uPer Element Wattage 240V Dimensions in Inches q cox. pct Sh9ppil g Wei ht lbs Standard Maximum A B C Tall Models ENT -30t 30 47 095 21 4500 1 6000 46112 3&V2 I9 95 EK401 40 51 095 21 4500 b000 60-I/4 53-1/A ZD 118 ENTB50' S0 70 095 1 21 1 4500 1 6000 1 601/d SL1/4 21 131 ENT -501 50 73 0.95 21 4500 6000 60.1/2 Sl -1l4 22 134 Es Est 55 76 094 21 4500 6000 1 12 49-1/2 24 145 Short Models EN:0_EN: 30 48 0.95 21 4500 6000 39 30-1/2 20 95 5 -301 30 L9 p.95 1 21 4500 6000 1 39-314 30-V2 1 22 94 ENS-0Or 40 55 0.95 21 4100 6000 50 403/4 20-1R 109 ENS 50t 50 6T 0.95 .1 1 4500 1 6000 49-314 1 40-3/0 1 23 161 Lowbo TooConnell Models ENL 2019.5 NSA WA 21 4500 6000 30 21-1/4 20 fi5 28 40 0.95 H 4500 fi000 30 2I-3/4 22 96 28 43 0.95 21 4500 6000 31416 21-3/4 24 115 38 46 0.95 21 4500 6000 31-314 24 24 118 38 c4 a 95 21 4500 6000 33-112 24 26 118 48 57 195 21 4500 6000 34 25 26 112 1 122 Mak 3W ancr mnnealoi on 8'aenler. `Mode6shlni vi suppll¢d lnsulallon blonkel. [Eo, 10 'rtankand 6 ,a, pans w11111N.shange'E'to" P' in the mdel onumbei@xamole ENHC becomes ENL 301 + To, T&PCpron not aoailable an toi5 mode EN 20 is n Idue elemsni mnlignabOn oily appdnal Tde location 421s used on the ENT TO, EM8 W, EN c55, ENS 4C and ENS 50 Top Eyla not aua ifl on the 10 yea, mcael PENN 50. Rnnaons and Specifications sun act to tnanye vi nonce In accordance vmn out ponry it a', woal Nprouemen, T&P VALVE ACCESS PANEL ACCESS PANEL DRAIN VALVE ANODE (OR OPTIONAL T&P LOCATION #1) } OPTIONALT&P ° LOCATION #2 C O ° O JUNCTION BOX T&P VALVE For technical information call 800 527-1953. A. 0. Smith Corporation reserves the right to make product changes or improvements without prior notice. 0 Febwa, 2016 A 0 Ed in Copi oil early ,,lived Pan, 2 if 2 .1hadeadle—ard 1900 11953 Toll -Fir- USA ACESUE50602 PERMIT SUBMITTAL DOCUMENTS