Loading...
HomeMy WebLinkAboutProduct Approval 8/28/2017 Florida Building Code Online a' r FLOR(OA,153PARTMOM OF ion Business ♦ Professional ' s ■ '' BCIS Home Log In I User Registration I Hot Topics Submit Surcharge I Stats&Facts I Publications I FBC Staff BCIS Site Map I Links I Search Florida Product Approval USER:Public Userot r RECEIVED Product Approval Menu>Product or Application Search>Aooiication List>Application Detail 9 2017 AUG 2 L • FL# FL15012-R2 Application type Revision PERMITTING Ct. Lucie County, FL Code Version 2014 S Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer C.H.I.Overhead Doors Address/Phone/Email 1485 Sunrise Drive Arthur,IL 61911 (217)543-2135 Ext 4273 phunter@chiohd.com Authorized Signature Pat Hunter phunter@chiohd.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Sectional Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer O Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed John E.Scates the Evaluation Report Florida License PE-51737 Quality Assurance Entity Architectural Testing,Inc. Quality Assurance Contract Expiration Date 12/31/2018 Validated By Gordon Thomas, P.E. W6 Validation Checklist-Hardcopy Received Certificate of Independence FL15012 R2 COI Cert of Ind Scates s.odf Referenced Standard and Year(of Standard) Standard Year ASTM E1886 2005 ASTM E1996 2009 ASTM E330 2002 DASMA 108 2002 DASMA 108 2005 DASMA 115 2005 Equivalence of Product Standards Certified By https://www.floddabuilding.org/pr/pi app_dti.aspx?param=wGEVXQwtDquS73Fr2ZyiPgc%2bhldlGcB6L5orvMJEkwLW9HhRp/`2bfdXSg%3d%3d 1/6 8/28/2017 Florida Building Code Online 15012.15 reL; 2240,2241,2250,2251,4240, 12'-00"wide through 21'-00"wide by 20'high steel sectional 4241,4250,4251,5240,5241, door with or without polystyrene insulation. 5250,5251 Limits of Use Installation Instructions Approved for use in HVHZ: No FL15012 R2 II Jamb Attach Drawings s.odf Approved for use outside HVHZ:Yes FL15012 R2 II Supplemental Instructions Pan s.Pdf Impact Resistant: No Verified By:John E. Scates,P.E. FL-51737 Design Pressure: N/A Created by Independent Third Party: No Other: Sectional doors provided for windload applications. Evaluation Reports Tested in accordance with ASTM E330 and ANSI/DASMA 108, FLIS012 R2 AE Eval Rept s.pdf which are accepted test methods per 5th edition(2014)Florida FL15012 R2 AE FZ3-16-013L5s.pdf Building Code Section 1715.See drawing FZ3-16-013L5 for Created by Independent Third Party:Yes pressures and widths+24.9(psf)/-27.7(psf)at 12'-00"through +10.9(psf)/-12.1(psf)at 21'-00". 15012.16 rf; 2240,2241,2250, 2251,4240, 14'-02"wide through 24'-00"wide by 20'high steel sectional 4241,4250,4251,5240, 5241, door with or without polystyrene insulation. 15250,5251 Limits of Use Installation Instructions Approved for use in HVHZ: No FL15012 R2 II Jamb Attach Drawings s.pdf Approved for use outside HVHZ:Yes FL15012 R2 II Supplemental Instructions Pan s.pdf Impact Resistant: No Verified By:John E. Scates,P.E. FL-51737 Design Pressure: N/A Created by Independent Third Party: No Other:Sectional doors provided for windload applications. Evaluation Reports Tested in accordance with ASTM E330 and ANSI/DASMA 108, FL15012 R2 AE Eva[ Rept s.ndf which are accepted test methods per 5th edition(2014)Florida FL15012 R2 AE FZ4-16-01315s.Ddf Building Code Section 1715.See drawing FZ4-16-01315 for Created by Independent Third Party:Yes pressures and widths+25.1(psf)/-27.9(psf)at 14'-02"through +10.5(psf)/-11.7(psf)at 24'-00" 15012.17 rfI; 2240,2241,2250,2251,4240, Up to 16-00"wide by 20'high steel sectional door with or 4241,4250,4251,5240,5241, without polystyrene insulation. 5250, 5251 Limits of Use Installation Instructions Approved for use in HVHZ: No FL15012 R2 II Jamb Attach Drawings s.Ddf Approved for use outside HVHZ:Yes FLIS012 R2 II Supplemental Instructions Pan s.pdf Impact Resistant:Yes Verified By:John E. Scates,P.E. FL-51737 Design Pressure:+22.2/-24.7 Created by Independent Third Party: No Other:Sectional doors provided for potential"code-plus" Evaluation Reports applications. Large Missile impact(9 pound missile)and cycling FLIS012 R2 AE Eval Rept s.odf tests conducted in accordance with ANSI/DASMA 115,ASTM FLIS012 R2 AE FZ4i-16-01515s.pdf E1886 and ASTM E1996.Static tests conducted in accordance Created by Independent Third Party: Yes with ASTM E330 and ANSI/DASMA 108.These are accepted test methods per 5th edition(2014) FBC Sections 1609 and 1715.See drawing FZ4i-16-01515 for pressures +22.2(psf)/-24.7(psf)at widths up to 16'-00" 15012.18 rg; 2240,2241,2250,2251,4240, 08'-00"wide through 16'-10"wide by 20'high steel sectional 4241,4250,4251, 5240,5241, door with or without polystyrene insulation. 5250,5251 Limits of Use Installation Instructions Approved for use in HVHZ: No FL15012 R2 II Jamb Attach Drawings s pdf Approved for use outside HVHZ:Yes FL15012 R2 II Supplemental Instructions Pan s.Ddf Impact Resistant: No Verified By:John E.Scates,P.E. FL-51737 Design Pressure: N/A Created by Independent Third Party: No Other:Sectional doors provided for windload applications. Evaluation Reports Tested in accordance with ASTM E330 and ANSI/DASMA 108, FL15012 R2 AE Eval Rept s.odf which are accepted test methods per 5th edition(2014)Florida FL15012 R2 AE FZ5-16-01315s.pdf Building Code Section 1715.See drawing FZ5-16-01315 for Created by Independent Third Party:Yes pressures and widths+52.4(psf)/-58.3(psf)at 08'-00"through +23.7(psf)/-26.3(psf)at 16'-10" 15012.19 04250,5251 ; 2240,2241, 2250,2251,4240, 12'-00"wide through 24'-00"wide by 20'high steel sectional 41,4250,4251,5240,5241, door with or without polystyrene insulation. Limits of Use Installation Instructions Approved for use in HVHZ: No FL15012 R2 II Jamb Attach Drawings s.pdf Approved for use outside HVHZ:Yes FL15012 R2 II Supplemental Instructions Pan s Ddf Impact Resistant: No Verified By:John E. Scates,P.E. FL-51737 Design Pressure: N/A Created by Independent Third Party: No Other:Sectional doors provided for windload applications. Evaluation Reports Tested in accordance with ASTM E330 and ANSI/DASMA 108, F1,15012 R2 AE Eval Rept s.pdf which are accepted test methods per 5th edition(2014)Florida FL15012 R2 AE FZ6-16-01315s.pdf Building Code Section 1715.See drawing FZ6-16-01315 for Created by Independent Third Party: Yes pressures and widths+40.1(psf)/-44.7(psf)at 12'-00"through +13.4(psf)/-14.9(psf)at 24'-00" 15012.20 rhI; 2240,2241, 2250,2251,4240, Up to 16'-00"wide by 20'high steel sectional door with or hftps://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquS73Fr2ZyiPgc%2bhldlGcB6L5orvMJEkwLW9HhR%2bfdXSg%3d%3d 5/6 4 3 2 1 16-0"(see notes for other widths) Window Options: Optional Standard Lites 3B intermediate 1/8" DSB 4D (see window options) 2 hinge 1/4" Tempered Glass 2 1C 2 1/4" Polycarbonate D top fixture7/16" Insulated Glass D flag 7/16" Tempered Insulated Glass bracket Max daylight opening 39-3/8 x 12-1/2" 4D f ? 2 + end stile 2 .a ca m track Door Height rn ° ° 3B bracket a a F a 2 6'-6"to T-0" 4 7 3-. end hinge 7'-6"to 8'-0" 5 9 4 C C 4A T-3"to T-9" 5 9 4 2 9'-0"to 10'-6" 6 11 5 bottom fixture 10'-9"to 12'-3" 7 13 6 �/ 12'-6"to 14'-0" 8 15 7 3A 2A 2 2 14'-3"to 15'-9" 9 17 8 This door has been evaluated in accordance with ASTM E 330-02 and ANSI/DASMA 108-02 and 108-05. strut attachment strut 16-0"to 1T-6" 10 19 9 Supporting structural elements to be designed by registered professional engineer for specified wind loads. 17-9"to 19'-3" 11 21 10 If door is not electrically operated,a lock must be installed. l9'-6"to 20'-0" 1223 11 B Maximum door height: 20'-0" Maximum section height: 21" B Per ASCE 7-10,Design Pressures(DP)typically meet or exceed the requirements for the following wind speeds. Track bracket quantities shown are for use with exposure"B"winds speeds are for Thigh doors on 30'tall buildings. grade 2 or better southern pine jambs.When usin These ex P Pe g g softer wood species like spruce-pine-fa(SPF)use Width Design Pressure Wind Speed Windows Center Stiles r 1 the quantity of track brackets specified in the chart 24'-00" 13.4 s /-14.9 s 122(mph) YES 9 plus three track brackets per side. / deInstructions l 21'-00" 17.5 s 19.4 s 140 m h YES 9 for oors uPto 20-0high.These are required in 20-06" 18.3 s /-20.4 s 143(mph) YES 9 addition to this drawing for installation. Always 20'-00" 19.3 s /-21.4(psf) 146(mph) YES 9 % I,lp 51737 use supplemental instructions in addition to this 19'-06" 20.3 s /-22.6 s 150(mph) YES 9 john E.States,P.E. * drawing during door installation. 19'-00" 21.3 s /-23.8(psf) 154(mph) YES 9 ' * 0 3121 Fairgate Drive 18'-06" 22.5 s /-25.1 s 158(mph) YES 9 nts Carrollton,Texas 75007 ��o STATE OF tu� 000 18'-00" 23.8 s /-26.5(psf) 162(mph) YES 7 �0p'•, p,:2 001.00000001' 04 09-2015 2240,2241,2250,2251,4240,4241, 17'-06" 25.2 s /-28.0 s t 66 m h YES 7 Florida P.E.# 51737 i�.r •.FtoRtQ: p�`�� A 16'-00" 30.1 s /-33:5 s 181(mph)- YES 7 ��//�S3�pNi;����� I Models:4250,4251,5240,5241,5250,5251 A 15-00" 132.1 s /-35.7 s 187(mph) YES 111 7 40.1(psf)/-44.7(psf)at 12'-00"through 14'-00" 34.4 s /-38.3 s 193 m h YES 5 L Digitally signed byl\ohn E.Scates,P.E.J 13.4(psf)/-14.9(psf)at 24'-00" 13'-00" 37.0 s 199 m h YES 5 1501692� Date:2015.04.141440:12-05'00' 12'-00" 40.1 s 44.7 s 207(mph) YES 1 5 C.H.I.Drawing: FZ6-16-01315 Center stile quantity is minimum per section. Professional Engineer's seal provided only for verification of windload construction details page 1_of 2 4 3 2 1 4 3 2 1 Strut(if applicable)not shown for clarity. Details on some views may have been omitted for clarity. (.059)galvanized steel top fixture. Each fixture attached The vertical wood jamb fasteners may be counter sunk to provide a flat mounting surface. D with four 1/4"x 3/4"screws. See jamb attachment details for more information about attaching jambs to structure. (.086)galvanized steel D flag bracket fastened to 2"x 7/16"(nominal)stop molding to be secured with wood jamb with three o 0 0 GO, push nut minimum 8d nail or 2-1/2"long screw on 5"spacing. 5/16"x 1-5/8"wood lag (.034)end stile Stop molding not required when door is more than V wider than opening. screws. nominal(.0185)galvanized steel minimum Flag bracket attached to horizontal track with two 1/4"x 5/8" (.109)galvanized steel top track bolts and nuts. «om fixture. Each fixture attached with two 1/4"x 3/4"screws. C C (.034)center stile 2"(min)x.0485(min Flag bracket attached to push nut galvanized steel track vertical track with two 1/4" x 5/8"track bolts and nuts. (.034)end stile C End Hinge V Intermediate Hinge Or two 1/4"x 11/32"rivets. galvanized steel fastened (.058)galvanized steel (.102)galvanized steel track 0 to section with Q fastened to section with bracket fastened to wood jamb C six 1/4"x 3/4"screws. four 1/4"x 3/4"screws. with one 5/16"x 1-5/8"wood ° 0 ® lag screw per bracket. ° Optional low head room top bracket Push nut ' 2"(max.for(.069)thick) 2 3/4" 2 3/4" 4"(max.for.109 thick) Each track bracket attached with B one 1/4"x 5/8"track bolt and nut. B Or two 1/4"x 11/32"rivets. nominal 02"(min.) � 3-1/2"(min.)stem 10(min.)ball roller with nylon or steel tread. push nut 3" 1 r , John E.Scares,P.E. I 3121 Fairgate Drive foo JA�- � 1-7/8" Carrollton,Texas 75007 Florida P.E.# 51737 c o O ID o 1/2" o11; ci3t+' i4 V-- oao su" nts (.102)galvanized steel � •� � M � � 000 .05150 ksi galvanized steel No,51737 ❑ o �000 04 09-2015 bottom bracket Each 3"strut attached with two 1/4"x 3/4" — r bracket attached with four _* * :.*- Models:2240,2241,2250,2251,4240,4241, screws per stile or hinge plate. red 1/4"x 3/4"screws. (.109)galvanized steel bottom ��o STATH ot- :� ` 4250,4251,5240,5241,5250,5251 `v'�I A cket A push nut brackwith et redEach 1/4a x 3/4 attached scres. D j%BtONA���O?` 13.4 pst)/-44.9 psr)at 12'-0 Hugh Vinyl Aluminum extrusion Optional low head room bottom bracket F L 5O12�2 1111111 weatherstrip C.H.I.Drawing: F16-16-01315 Professional Engineer's seal provided only for verification of windload construction details page_2_of 2 4 3 2 1 Anchor:ITW Tapcon or Tapcon LDT or Simpson Strong-Tie. keep each area clear of p any back jamb ITW Ramset/Redhead Tapcon,1/4"diameter,minimum 3.5"long with washer that conforms to ANSI B18.22.1 type B. attachment fasteners ITW Ramset/Redhead Large Diameter Tapcon,3/8"diameter,minimum 4"long with washer that conforms to ANSI B18.22.1 type B. / Simpson Titen HD,3/8"diameter,minimum 4"long with washer that conforms to ANSI B18.22.1 type B. 3 Simpson Wedge-All,3/8"diameter,minimum 4"long with washer that conforms to ANSI B 18.22.1 type B. 8" When applying back jambs over dry wall or other non structural wall covering,use longer fasteners to insure minimum embedment required. 1 header / This chart applies to wood species with specific gravity greater than or equal to 0.42 including spruce pine fir(SPF)and southern pine(SP). See chart for minimum washer diameter. Washer diameters in chart are based on use of Spruce Pine Fir. Washers may be 10%smaller when Southern Pine is used. 8" See chart for minimum edge distance required. Lowest anchor to be greater than the minimum edge distance up from the floor and less than 10-inches from the floor. I/ FASTENER SPACING(inches) 2500 psi concrete Filled CMU Simpson ITW Tapcon Strong-Tie DOOR WIDTH(feet and inches)at a given DESIGN PRESSURE(PSF) 1/4" 2/4"13/8. 3/8 3/8"13/8" 14psf 17 sf 20psf 24psf 28psf 32psf 36psf 40psf 44psf 48 sf 53psf 58psf 63psf 69psf 75psf 81psf 87psf 93psf 24 24 24 24 24 24 22'-9 18'-9 15'41 13'-3 11'-4 9'-11 V-30 V-11 V-3 6'-7 V-0 V-6 V-0 W-7 4'-3 T-11 n/a n/a 24 22 24 24 24 24 24'-3 20'-0 17'-0 14'-1 12'-1 10'-7 9'-5 V-6 T-8 T-0 6'-4 V-10 5'-4 4'-11 4'-6 4'-2 n/a n/a 24 20 24 24 24 16 26'-6 21'-9 18'-6 15'-5 13'-3 11'-7 10'-3 9'-3 8'-5 V-8 T-0 6'-4 5'-10 V-4 4'-11 4'-6 4'-3 V-11 24 18 24 22 24 16 28'-10 23'-9 20'-2 16'-10 14'-5 12'-7 11'-2 10'-1 9'-2 V-5 V-7 V-li V-5 5'-10 5'-4 4'-11 4'-7 4'-4 24 17 24 20 24 16 31'-9 26'-2 22'-3 18'-6 15'-1013'-10 12'-4 11'-1 30'-1 V-3 8'-4 7'-8 7'-0 V-5 5'-11 5'-5 V-1 4'-9 24 1 15 24 18 24 16 34'-3 28'-2 24'-0 20'-0 17'-1 15'-0 13'-4 12'-0 10'-10 10'-0 9'-0 V-3 V-7 W-11 1 V-4 5'-11 5'-6 5'-1 24 15 24 17 16 16 36'-3 29'-10 25'-4 21'-2 18'-1 15'-10 14'-1 12'-8 11'-6 10'-7 9'-7 8'-9 8'-0 7'-4 6'-9 6'-3 V-10 5'-5 High estanchorinstalled 22 13 24 16 16 8 n/a 32'-3 27'-5 22'-10 19'-7 17'-1 15'-2 13'-8 12'-5V-5 10'-4 V-5 V-8 7'-11 7'-3 6'-9 V-3 V-10 least as high as door opening. o 21 1 13 24 15 16 8 n/a 33'-10 28'-9 24'-0 20'-6 38'-0 16'-0 14'-4 13'-1 12'-0 10'-10 V-11 V-1 V-4 7'-8 7'-1 V-7 V-2 Anchors to be evenly spaced between 19 1 12 24 14 16 8 n/a n/a 31'-4 26'-1 22'-5 19'-7 17'-5 15'-8 14'-3 13'-0 ll'-10 10'-9 9'-11 9'-1 8'-4 T-8 T-2 6'-8 the header and the floor. 16 1 10 24 12 16 8 n/a n/a 36'-0 30'-0 25'-8 22'-6 20'-0 18'-0 16'-4 15'-0 13'-7 12'-4 11'-5 10'-5 9'-7 8'-10 V-3 T-8 16 10 24 11 8 8 n/a n/a n/a 31'-9 27'-2 23'-9 21'-2 19'-0 17'-3 115'-10114'-4 13'-1 12'-1 11'-0 10'-i 9'-4 8'-9 dIV-11 14 8 24 10 8 8 n/a n/a n/a 35'-9 30'-8 26'-10 23'-30 21'-5 19'-6 17'-10 16'-2 14'-9 13'-7 12'-5 11'-5 10'-7 9'-10 12 7 20 9 8 8 n/a n/a n/a n/a n/a 30'-11 27'-5 24'-8 22'-5 20'-7 18'-8 17'-0 15'-8 14'-4 13'-2 12'-2 11'-4 2x6 structural grade lumber. 11 7 20 8 8 8 n/a n/a n/a n/a n/a 31'-10 28'-3 25'-6 23'-2 21'-3 19'-2 17'-7 16'-2 14'-9 13'-7 12'-7 11'-8 May be counterbored up to 3/8"deep 10 6 17 7 8 n/a n/a n/a n/a n/a n/a n/a 32'-0 28'-9 26'-2 24'-D 21'-8 19'-30 18'-3 16'-8 15'-4 14'-2 13'-2 at each anchor location to provide a 9 n/a 16 6 8 n/a n/a n/a n/a n/a n/a n/a n/a 32'-0 29'-1 26'-8 24'-1 22'-0 20'-3 18'-6 17'-0 15'-9 14'-8 flush mounting surface. 8 n/a 13 6 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 30'-11 28'-0 25'-7 23'-6 21'-6 19'-9 18'-3 17'-0 n/a n/a 12 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 32'-4 29'-7 27'-3 24'-10 22-10f2l'-2 19'-8 f93ps]f e e 2500 psi concrete Filled CMU 14psf 17psf 20psf 24psf 28psf 32psf 36psf 40psf 44psf 48psf 53psf 58psf 63psf 69psf 75psf f 87psf p First anchor to start at no more than Titen wedge- DOOR WIDTH feet and inches ata given DESIGN PRESSURE PSF half the fastener spacing distance and ITW Tapconh3/8" LDT HD All ( ) g ( ) no less than the minimum edge distance. 1/4" 1/4" 3/8" 3/8" 3/8" FASTENER DIAMETERe 1.75" 1.75" 2.5" 2.75" 2.68" EMBEDMENT LENGTH7/8" 1" 1-1/8'1-1/8"WASHER DIAMETERSupporting structural elements shall be designed by a registered 2-1/2"2-1/2" 3" 4" 4" EDGE DISTANCE `` �\ S. s`Cd����/ professional engineer for wind loads in addition to other loads. 508# 319# 859# 371# 480# 340# FASTENER LOAD CAPACITY ���.. This drawing does not address the jamb/wall design,but only door \\ �O /;10! attachment.Jamb/wall construction is shown only for illustration purposes. The building designer is responsible for ensuring that the D 51737 N jamb/wall is sufficient to carry the door live and static loads. This � � drawing does not address the spring pad connections. Registered * j* professional engineer may approved an alternative design. Digitally signed by John E.SCates,P.E. Manufacturer's installation instructions must be followed. Date:2015.02.2416:32:57-06'00' * i' SCALE Maximum spacing shown in chart. i .p . gTATE OF ` �0� none John E.Scates,P.E. Lesser spacing may be used to avoid interference with door hardware / 'p i 41 ��� DATE 3121 Fairgate Drive i0 •. `�OR,O 62\ RM (�00 2-18-2015 and or fastening system,but not less than 6". / .R w, \ 0 0 o s Carrollton,Texas 75007 _ Load per jamb=0.5 x door width x max positive pressure x door height. Florida P.E.#51737FtS's+ 8"CMU block walls shall comply with ASTM C90. TXPE 56308,F-2203 �/ /ONAL ��� Back Jamb Attachment Detail Use minimum 2000 psi grout or concrete when filling CMU. /SII I I I 110 Concrete Anchors CMU fastener spacing distance may vary+/-1". Professional Engineer's seal provided only for verification of windload construction details. C.H.I.Drawing: BJA-101 ReV.-07 Southern Pine(SP)specific gravity=0.55;allowable load per anchor=620 pounds. 1/2"MIN IA"MIN 1/2"MIN 1/2"MIN Spruce Pine Fir(SPF)specific gravity=0.42;allowable load per anchor=482 pounds. ATTACHMENT OF Use SP values only if both structure and jamb are southern pine. 2x6 WOOD JAMB ATTACHMENT OF Use SPF values when spruce pine fir is resent in structure orjamb material. 2x6 WOOD JAMB P P P � %z"SHEATHING ON SHEATHING Lag screw:3/8"diameter x 3"minimum long;must conform to ANSI/ASME B 18.2.1 Washer:1-1/8"minimum outside diameter,must conform to ANSI B18.22.1 type A. Pre-drill 1/4"diameter pilot holes for lag screw insertion. 1-1/2"minimum lag screw edge distance required. Ys"x 3"LAG SCREWS y"SHEATHING FASTENER DOOR WIDTH (feet and inches) at a given DESIGN PRESSURE (PSF) 8"x3-t/z"LAG SCREWS keep each area SPACING clear of any back SPF SP 14psf 17psf 20psf 24psf 28psf 32psf 36psf 40psf 44psf 48psf 53psf 58psf 63psf 69psf 75psf 81psf 87psf 93psf jamb attachment 24 24 34'-5 28'-4 24'-1 20'-0 17'-2 15'-0 13'-4 12'-0 10'-1110'-0 9'-1 8'-3 7'-7 6'-11 6'-5 5'-11 5'-6 5'-2 fasteners 22 24 n/a 32'-4 27'-6 22'-Il 19'-8 17'-2 15'-3 13'-9 12'-6 11-5 10'-4 9'-S 8'-S 7'-11 7'-4 6'-9 6'-3 S'-11 20 24 n/a 34'-0 28'4124'-1 20'-7 18'-0 16'-0 14'-5 13'-1 12'-0 10'-1 9'-11 9'-2 8'-4 7'-8 7'-1 6'-7 6'-2 18 24 n/a 36'-5 31'-0 25'-1 22'-1 19'-4 17'-2 15'-6 14'-1 12'-1 11'-8 10'-8 9'-10 8'-11 8'-3 7'-7 7'-1 6'-8 header / 18 23 n/a n/a 32'-1 26'-9 22'4120'-0 17'-1 16'-0 14'-7 13'-4 12'-1 11'-0 10'-2 9'-3 8'-6 7'-11 7'-4 6'-10 16 21 n/a n/a 35'-5 29'-6 25'-3 22'-1 19'-8 17'-8 16'-1 14'-9 13'-4 12'-2 11'-2 10'-3 9'-5 8'-8 8'-1 7'-7 _� a 16 20 n/a n/a 36'-1 30'-1 25'-9 22'-7 20'-0 18'-0 16'-5 15'-0 13'-7 12'-5 11'-5 10'-5 9'-7 8'-11 8'-3 7'-9 3" 15 20 n/a n/a n/a 31'-0 26'-6 23'-3 20'-8 18'-7 16'-1 15'-6 14'-0 12'-9 11'-9 10'-9 9'-11 9'-2 8'-6 8'-0 -� 14 18 n/a n/a n/a 34'-5 29'-6 25'-9 22'-1120'-7 18'-9 17'-2 15'-7 14'-2 13'-1 11'-1 11'-0 10'-2 9'-5 8'-10 13 16 n/a n/a n/a n/a 31'-9 27'-9 24'-8 22'-2 20'-2 18'-6 16'-9 15'-4 14'-1 12'-1 11'-1 10'4110'-2 9'-6 12 16 n/a n/a n/a n/a 33'-2 29'-0 25'-1 23'-3 21'-1 19'-4 17'-6 16'-0 14'-9 13'-5 12'-4 11'-5 10'-8 10'-0 a 12 15 n/a n/a n/a n/a n/a 30'-1 26'-9 24'-1 21'-1 20'-0 18'-2 16'-7 15'-3 13'-1112'-10 11'-1 11'-0 10'-4 11 14 n/a n/a n/a n/a n/a 32'-1 29'-2 26'-3 23'-1 21'-1 19'-1 18'-1 16'-8 15'-2 14'-0 12'-1112'-1 11'-3 10 14 n/a n/a n/a n/a n/a 33'-2 29'-6 26'-6 24'-1 22'-1 20'-0 18'-3 16'-1 15'-4 14'-2 13'-1 12'-2 11'-5 10 12 n/a n/a n/a n/a n/a n/a 32'-1 28'-1126'-3 24'-1 21'-9 19'4118'-4 16'-9 15'-5 14'-3 13'-3 12'-5 Highest anchor installed at 9 12 n/a n/a n/a n/a n/a n/a n/a 31'-0 28'-2 25'-1 23'-4 21'-4 19'-8 17'-1116'-6 15'-3 14'-3 13'-4 least as high as door opening. u 9 11 n/a n/a n/a n/a n/a n/a n/a 32'-1 29'-2 26'-9 24'-3 22'-1 20'-4 18'-7 17'-1 15'-1 14'-9 13'-9 / Anchors to be evenly spaced between 8 11 n/a n/a n/a n/a n/a n/a n/a n/a 30'-8 28'-2 25'-6 23'-3 21'-5 19'-7 18'-0 16'-8 15'-6 14'-6 the header and the floor. 8 10 n/a n/a n/a n/a n/a n/a n/a n/a 32'-1 30'-1 27'-3 24'-1122'4120'-1129'-3 17'-1 16'-7 15'-6 7 10 n/a n/a n/a n/a n/a n/a n/a n/a n/a 31'-0 28'-0 25'-7 23'-7 21'-6 19'-1118'-4 17'-1 16'-0 ° o 7 9 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 31'-2 28'-5 26'-2 23'-1 22-0 20'-4 18'-1117'-9 6 8 n/a n a n/a n/a n/a n/a n/a n/a n/a n/a n/a 32'-0 29'-6 26'-1 24'-9 22'-1 21'-4 20'-0 2x6 structural grade lumber. / May be counterbored up to 3/8"deep at 4 6 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 33'-0 30'-7 28'-6 126'-8 each anchor location to provide a SPF SP 14 sf 17 sf 20 sf 24 sf 28 sf 32 sf 36 sf 40 sf 44 sf 48 sf 53 sf 58 sf 63 sf 69 sf 75 sf 81 sf 87 sf 93 sfFASTENER flush mounting surface. P P p P P P P P P P P P P P P P P P SPACING DOOR WIDTH (feet and inches) at a given DESIGN PRESSURE (PSF) ° ° 482#1620# 111+�� `/ \� �/ First anchor to start at no more than LOAD PER \\\\ E, /// half the fastener spacing distance and FASTENER $(,qr,.. • no less than the minimum edge distance. (Pounds) ��'� GEN3�•••1b /i ° Maximum load per jamb=0.5 x(door height)x(door width)x(maximum positive pressure) ; NO.0737 is When applying back jambs over dry wall or other non structural wall covering, SCALE use longer lags screws to insure 1-1/2"minimum embedment required none Lesser spacing may be used to avoid interference with door hardware and or fastening system. .p STATE OF i 4-f (�j ❑w❑ ❑O�0 DATE Maximum spacing shown in chart. John E.Scates,P.E. % �. ��� o 2-18-2015 These charts do not address spring ad connections to the building. 3121 Fair ate Drive �/��••• ORQ. 0 N Back Jamb Attachment Detail Alternative design may be approved b are registered professional engineer. Carrollton,Texas 75007 /// Fs ••�� s y PP y g P /// S10NAL���\�\ Lag Screw Supporting structural elements shall be designed by a registered professional Florida P.E.#51737 /////I ��X engineer for wind loads in addition to other loads. TXPE 56308,F-2203 11 I I%% C.H.I. Drawing: BJA-102 ReV.-OS Professional Engineer's seal provided onl for ventication of wmd load construction detailsg Self tapping screws (with steel) Screw:1/4"dia x 3/4"self tapping screw;must conform to ANSI/ASMEB18.2.1. .100" x 1"fillet welds USE 9/16" %e"steel Jambs;allowable load per screw=444 lbs. Welds performed by a Certified Welder or inspected by a MINIMUM track Allowable load per screw;12 gauge=209 lbs,14 gauge=143 lbs,and 16 gauge=110 lbs. Certified Welding Inspector to verify integrity of welds. DIAMETER Optional Washer.9/16"O.D.minimum;must conform to ANSI B18.22.1 a A. 12 gauge or/e"steel Jambs;allowable load per weld=1,272 lbs. revers WASHER IF bracket or p Use all necessary precautions when welding galvanized steel. SSW Washer not required if fastener head has minimum 9/16"outside diameter. Welds to be event aced between header and floor. continuous y Lowest fastener to be within 10-inches of the floor ang IS LESS THAN Lowest weld to be within 10-inches of the floor 9/16"DIAMETER gle Maximum spacing shown in chart. Lesser spacing may be used to avoid interference Minimum of 3 welds per jamb required. with door component system. Add holes to continuous angle as required to satisfy fastener spacing in these charts. Fillet welds to have a straight or convex face surface. These charts do not address spring pad connections to the building. Tack weld toe of angle at same spacing to prevent rotation of track angle. ATTACHMENT SPACING(inches) Load per jamb=0.5 x door width x max positive pressure x door height Cracks and blemishes shall be ground to a smooth contour and checked to ensure soundness. SCREWS SCREWS SCREWS WELDS SCREWS WELDS These charts do not address spring pad connections to the building. 16 ga 14 ga 12 ga 12 ga 3/16" 3/16" DOOR WIDTH(feet and inches)at a given DESIGN PRESSURE(PSF) Load per jamb=0.5 x door width x max positive pressure x door height jamb jamb jamb jamb jamb jamb 14psf 17psf 20psf 24psf 28psf 32psf 36psf 40psf 44psf 48psf 53psf 24 31 36 36 36 36 7'-10 6'-5 5'-6 4'-7 3'-11 3'-5 3'-0 n/a n/a n/a n/a 20 26 36 36 36 36 9'-5 7'-9 6'-7 5'-6 4'-8 4'-1 3'-8 n/a n/a n/a n/a track bracket or 18 24 36 36 36 36 9'-11 8'-2 6'-11 5'-9 4'-11 4'-4 3'-10 n/a n/a n/a n/a continuous angle *(1E60'XrXeVE1cctrodes se angle 16 20 30 36 36 36 IV-9 9'-8 8'-3 6'-10 5'-10 5'-1 4'-7 4'-1 n/a n/a n/a 14 18 26 36 36 36 13'-5 11'-1 9'-5 7'-10 6'-8 5'-10 5'-2 4'-8 4'-3 3'-11 n/a 12 16 24 36 36 36 14'-1112'-3 10'-5 8'-8 7'-S 6'-6 5'-9 5'-2 4'-9 4'-4 3'-11 12 15 22 36 36 36 15'-8 12'-1111'-0 9'-2 7'-10 6'-10 6'-1 5'-6 5'-0 4'-7 4'-1 9 12 17 36 36 36 20'-5 16'-9 14'-3 11'-1110'-2 8'-11 7'-11 7'-1 6'-6 5'-11 5'-4 4'-11 4'-6 4'-1 n/a n/a n/a n/ag fillet weld 8 10 16 36 34 36 22'-4 18'-5 15'-8 13'-0 11'-2 9'-9 8'-8 7'-10 7'-1 6'-6 5'-10 5'-4 4'-11 4'-6 4'-2 n/a n/a n/a Min). 7 10 14 36 31 36 24'-6 20'-2 17'-1 14'-3 12'-3 10'-8 9'-6 8'-6 7'-9 7'-1 6'-5 5'-11 5'-5 4'-11 4'-6 4'-2 3'-11 n/a weld ilocated vertically on angle at sing ing specified in chart 6 8 12 36 25 36 29'-10 24'-7 20'-1017'-5 14'-1113'-0 11'-7 10'-5 9'-6 8'-8 7'-10 7'-2 6'-7 6'-0 S'-6 5'-1 4'-9 4'-5 and tack weld toe of angle or 6 7 11 36 24 36 31'-S 25'-10 22'-0 18'-4 15'-8 13'-9 12'-2 11'-0 10'-0 9'-2 8'-3 7'-7 6'-11 6'-4 5'-10 5'-5 5'-0 4'-8 track bracket at same spacing. n/a 6 8 36 18 36 40'-10 33'-7 28'-7 23'-10 20'-5 17'-1015'-1014'-3 13'-0 11'-1110'-9 9'-10 9'-0 8'-3 7'-7 7'-0 6'-6 6'-1 n/a 5 7 36 16 36 n/a 39'-2 33'-3 27'-9 23'-9 20'-9 18'-6 16'-7 15'-1 13'-1012'-6 11'-5 10'-6 9'-7 8'-10 8'-2 7'-7 7'-1 n/a n/a 6 36 12 36 n/a n/a 41'-9 34'-1 29'-10 26'-1 23'-2 20'-1019'-0 17-5 1S'-9 14'-4 13'-3 12'-1 11'-1 10'-3 9'-7 8'-11 n/a n/a 5 32 it 32 n/a n/a n/a 39'-9 34'-0 29'-9 26'-6 23'-10 21'-8 19'-1 18'-0 16'-5 15'-i 13'-9 12'-8 11'-9 10'-1110'-3 n/a n/a n/a 30 10 30 n/a n/a n/a n/a 36'-4 31'-9 28'-3 25'-5 23'-1 21'-2 19'-2 17'-6 16'-1 14'-8 13'-6 12'-6 11'-8 10'-11 n/a n/a n/a 26 9 26 n/a n/a n/a n/a n/a 36'-8 32'-7 29'-4 26'-8 24'-5 22'-1 20'-2 18'-7 17'-0 15'-7 14'-S 13'-5 12'-7 n/a n/a n/a 24 8 24 n/a n/a n/a n/a n/a n/a 35'-4 31'-9 28'-10 26'-6 24'-0 21'71120'-2 18'-5 16'-1115'-8 14'-7 13'-8 n/a n/a n/a 16 5 16 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 32'-10 30'-3 27'-7 25'-5 23'-6 21'-1120'-6 n/a n/a n/a 14 n/a 14 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 31'-7 29'-0 26'-1125'-0 23'-5 n/a n/a n/a 12 n/a 12 n/a I n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 31'-4 29'-2 27'-4 SCREWS SCREWS SCREWS WEEDS SCREWS WELDS 14psf 17psf I 20psf 24psf 128psf I 32psf 1 36psf I 40psf 44psf 48psf 53psf 58psf 63psf 69psf 75psf 81psf 87psf 93psf 16 ga 14 ga 12 ga 12 ga 3/16" 3/16" DOOR WIDTH(feet and inches)at a given DESIGN PRESSURE(PSF) Alternative design may be approved by a jamb jamb jamb jamb I jamb jamb licensed professional engineer. ATTACHMENT SPACING(inches) 11 Supporting structural elements shall be --11-0#-T--143#-7 209# 1 1272#1 444# 1272# ``,11 (7��/ designed by a licensed professional engineer ALLOWABLE LOAD PER SCREW(pounds) �� E• C (, / for wind loads in addition to other loads. �a 3 ��� ��' This drawing does not address the jamb/wall O♦♦♦��♦E'Ns�``� // design,but only door attachment Jamb/wall 1. ♦ V �� / construction is shown only for illustration • purposes.The building designer is responsible • o N .0737 • 1 — for ensuring that the jamb/wall is sufficient to carry the door live and static loads. � *i ; •� � SCALE • 000 none OF ♦♦,,-- John E.Scates,P.E. A`` STATE �y�\ o TOMJ A 000 DATE 2-18-2015 3121 Fairgate Drive %0*'�•� (OR\�4: d� > T ori 56 08#51737 Carrollton,Texas 75007 /��� s�NA;����`` Steel Attachment Detail �III� Professional Engineer's seal provided only for verification of windload construction details. C.H.I. Drawing: BJA-103 I Rev.-07