HomeMy WebLinkAboutProduct Approval (3) - LE
} i`/MIAM -21ADE
® MiANII RADE COUNTY
• PRODUCT CONTROL SECTION
DEPAR"01V'T.OI+'REGULATORY AND ECONOMIC RESOURCES WR) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) • www.mlamidRdemoy/economy ' .
Sun-Tek Manufacturing,Inc.
10303 General Drive
Orlando,FL 32824
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
This NOA shall not be valid after the expiration date stated below. The Miami Dade County Product Control
Section (Irl Miami Dade County) and/or the A14J (in areas other than Miami Dade County)reserve the right to
have this product or material tested for quality assurance ptirposes.If this product or material fails to perform in
the. accepted manner, the manufacturer will incur the expense of such testing•and the AHJ may immediately
revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami Dade County Product Control Section that this product or
material-fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the High Velocity Hurricane
Zone of the Florida Building Code.
DESCRIPTION: ISFG Skylight System
APPROVAL DOCUMENT: Drawing No. STI-00000298'
TI 00000298,titled"ISFG",sheet 1 &2 of 2,prepared by Sun-Tek
Manufacturing,Inc., dated August 07,-2007,last revision#A dated May 04,2015, signed and sealed by James D.
Wells, Jr., P.E., on May 04, 2015, bearing the MiamiDade County Product Control Revision stamp with the
Notice of Acceptance number and the expiration date by the Miami-Dade County Product Control Section.
MMSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Each unit shall bear a-permanent label with the manufacturer's name or logo, city, state,
model/series and the following statement: "Miami-Dade County Product Control Approved", unless otherwise
noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for.sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any"section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall
be done in its entirety.
'INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA#13-1028.05 and consists of this page 1, evidence submitted pages E-1,E-2, &E-3, as
well as approval document mentioned above.
The submitted documentation was reviewed by Helmy A.Makar,F.E.,M.S.
HAMMWECOU k�� NOA No.I5-0513.10
W. Expiration Date: 10/3112018
vq /03/2015.. Approval Date: 09/03/2015
Page 1
ti
Sun-Tek Manufacturing,Inc
NOTICE OF ACCEPTANCE:EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL 407-0425.04
A. DRAWINGS
1. DrawingWo. STI-00000298-SMIISR7Z titled "ISFO"P sheet I & 2 of 2,prepared
by Sun-Tek Manufacturing, Inc, dated 06104107 with last revision dated 08107107,
signed and sealed by James D. Wells,Jr., P.E.
B. TESTS(submitted under NOA#02-0618.06)
1. Test Report on Large Missile Impact Test per PA 201, Cyclic Wind Pressure Test per
PA 203 and Uniform Static Air Pressure Test per PA 202 of"Insulated Glass Skylight
with Polycarbonate Inner Liner" prepared by National Certified Testing
Laboratories, Report No. 210-2760-1, 2 &3, dated 01122102, signed and sealed by B.
Portnoy, P.E.
C. CALCULATIONS
1. Anchor Calculations for attachment.of skylight to curbing and curbing to decking,
dated 08113107, signed and sealed by James D. Wells, Jr., P.E.
D. MATERIAL CERTIFICATIONS (submitted under NOA#02-0618.06)
1. Test report on Rate of Burningper ASTMD635 of Geon 87416 White 141
Exterior, 0.137 inch,prepared by Commercial Testing Company, Report No 01-
11293, dated 11129101, signed by J Jackson -
2. Test report on Self Ignition Temperature per ASTMD1929 of Geon 87416 White
141 Exterior,prepared by Commercial Testing Company, Report No. 01-11292,
dated 11129101, signed by J Jackson.
E. STATEMENTS{submitted under NOA#02-0618.06)
1. Code compliance letter issued by Product Technology Corporation. on 09127102,
signed and sealed by R J Quiroga P.E.
F. OTHER
1. NOA renewal request letter issued by Sun-Tek Manufacturing, Inc., dated 08116107,
James Feudner.
2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#11-0601.02
A. DRAWINGS
1. Drawing No. STI-00000298-SRTIISRT2, titled "ISFG". sheet I &2 of 2,prepared
by Sun-Tek Manufacturing, Inc, dated August 07, 2007, .last revision #A dated
October 14, 2011, signed and sealed by James D. Wells, Jr., P.E.
Cirelmy A.Makar,P.E.,KS.
Product Control Section Supervisor
NOA No.15-0513.10
Expiration Date: 10/31/2018
Approval Date*. 09/0312015
i
Sun-Tek Manufacturins,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
B. TESTS
1. Test Addendum for Test Report NCTL 210-2760-1, prepared by national Certified
Testing Laboratories, dated October 17, 2011, certifying the interlayer thickness,
signed by Mark Bennett, Manager of Testing Services.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
-1. By Miami-Dade County Department of Permitting, Environment, and Regulatory
Affairs(PERA).
E. MATERIAL CERTIFICATIONS
1. None.
3. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL 412-1011.15
A. DRAWINGS
1. Drawing No. STI-00000298, titled "ISFG", sheet 1 & 2 of 2, prepared by Sun-Tek
Manufacturing Inc, dated August 07, 2007, last revision #A dated May 03, 2012,
signed and sealed by James D. Wells, Jr., P.E.
B. TESTS
1. .None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miami-Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. None.
F. OTHERS
1. A compliance letter,prepared by.J&L Wells Consulting LLC, dated April 25, 2012,
certify compliance with FBC 2010 edition, sign&sealed by James.D. Wells, Jr.,P.E.
2. Verification testing to -be performed per letter from National Certified Testing
Laboratories, dated September 18, 2012, signed by Christopher Bennett.
Helmy A.Makar,P.E.,M.S.
Product Control Section Supervisor
NOA No.15-0513.10
Expiration Date: 10/31/2018
Approval Date: 09/03/2015
E-2
Sun-Telt Manufacturing,Inc.
NOTICE OF ACCEPTANCE:EVIDENCE SUBMITTED
4. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#13-1028.05
A. DRAWINGS
1. Drawing No. STI-00000298, titled `ISFG", sheet 1 &'2 of 2, prepared by Sun-Tek
Manufacturing, Inc., dated August 07, 2007, last revision #A dated August 15, 2013,
signed and sealed by James D. Wells, Jr., P.E., on February 07, 2014.
B. TESTS
1. Test Report on Large Missile Impact Test per PA 201, Cyclic Wind Pressure Test per
PA 203 and Uniform Static Air Pressure Test per PA 202 of`Insulated Glass Skylight
with Polycarbonate Inner Liner" prepared by National Certified Testing
Laboratories, Report No. 210-3915-01, dated 0812712013, signed and sealed by
Gerard Ferrara, P.E.
C. CALCULATIONS
1. Anchor Calculations for attachment of skylight Model ISFG to Decking, dated
1010312013, signed and sealed by James D. Wells, Jr., P.E.
D. QUALITY ASSURANCE
1. By Miami Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. Bill of Material and Components Die Drawings.
5. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. STI-00000298, titled "ISFG", sheet 1 & 2 of 2, prepared by Sun-Tek
Manufacturing, Inc.,-dated August 07,' 2007, last revision #A dated May 04, 2015,
signed and sealed by James D. Wells, Jr., P.E., on May 04, 2015.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. -QUALITY ASSURANCE
1. By Miami-Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS .
1. None.
elmy A.Makar,P.E.,M.S.
Product Control Section Supervisor
NOA No.15-0513,10
Expiration Date: 10/31/2018_
Approval Date: 09/03/2015
E-3
PART NAME: ISFG SKYLIGHT ASSEMBLY FILE NAME: Z:1DWG\DWGIACAD 2000 DRAWINGS\DADE COUNTY ISFG STI-00000298
STI-215.DECO COVER 0.075 6063 T6 ALUM 17132"GLASS BITE ,
118" OUTBOARD DSB TEMPERED
SILICONE BEDDING (CONTINUOUS) 1/8" INBOARD GLASS DSB TEMPERED
STI-6 GLASS GASKET EPDM
(CONTINUOUS) r INSULATED AIR SPACE
ARGON GAS FILLED
STI-401 WOOD LINER 1.16x0.935"
(CONTINUOUS) SWIGGLE SPACER(0. 5)
#8-32 PHILLIPS PAN HD SCREW AND HEX NUT
7 PER LONG SIDE 7 PER SHORT SIDE
.177 POLYCARBONATE SHEET
PALRAM PALSUN
CL
BUTYL 3 RINGS OF SEALANT STI-300 PVC LINER
00 ::3 BENEATH FLANGE (CONTINUOUS) LEON 87416 WHITE
0� O AROUND PERIMETER OF FLANGE 141 EXTERIOR
w (CONTINUOUS) AND ON TOP OF EACH
z v FLANGE SCREW
Q AIR SPACE OR
Lr
DADE COUNTY APPROVED
cn SHINGLES EXPANDED POLYSTYRENE INSULATION
(SEE NOTE 1)
ROOF DECK mina" thick
DESIGN PRESSURE RATING+/- 80 PSF.
LARGE MISSILE IMPACT RESISTANCE
Engineer of Record
James D. Wells, Jr.,P.E.
Professional Engineer No. 53616 NOTE:
* (1) ALL ROOFING DETAILS SHALL COMPLY WITH
nu A nTcn 4= nr-ruc CI no lnA 01 11I nI?%Ir'_ nnnC 7r11 A crli+in
PART NAME: ISFG SKYLIGHT PLAN VIEW FILENAME: Z:IDWGIDWGIACAD 2000 DRAWINGSIDADE COUNTY ISFG STI-00000298
54.5 STI-214 DECO R
tip to tip o
4.000 4000
5 8125 . 0o SILICONE BEC
5.8125 �: STI-6 GLA:
5.8 25 5. 125
--- _ — STI-4
STI-205 CMG FRAME 0.06(
5.8125 h WELDED CORNERS
f #8-32 Xi"PHILLIPS
AND HEX N
FASTENERS SKYLIGHT s
TO DECK#8 X 1" (9) PER SIDE AND BOTT
STI-20.
U.� AP
ti
0J
I ISFG 4949 I I w 0 3'RI1
O W I3ENEA1
_� _ N: z Q AROUN
SYME RICAo (CONTINUO
Ill- Lo
O SH'.
�(SE
0
#8 X 1"PHILPS PA9
FASTENERS SUB-FRAME TO FRAME ~ SCREW(9)PER
I I o a min.protr
I
I ti ROOF DE4
4"MININUM LIP
o ROOF SURFA(
t- o
DESIGN PRESSURE RATING+/-80 PSF.� o
LARGE MISSILE IMPACT RESISTANCE N Engineer of Record
NOTE: James D. Wells, Jr.,P.E.
* (1)ALL ROOFING DETAILS SHALL COMPLY WITH Professional Engineer No. 53616
ruAo--r-D IR nC Tum M 001r)A Ri iii r1inir rrnnr: ')nlA crl;+inn PRODUCT REVISED
Florida http://www.floridabuilding.org/pr/,pr Code Online http: www.floraung.orgp ,pi�
joridd idbildi / r/ _appjtl.aspx?param=-w(iE VX_
BCIS Home Log In • UserReglstratlon
Hot Topics Submit Surcharge stats&Facts f Publications FSC Staff BCISSJteMa
�p Product Approval
USER:Public User
SSI.On
Pro I ow
>EmdLiOt nLAaRn!,,,!jrign�—�-h>Applujij�,. >Application Detail
FL
J Revision
FL2569-R11
Application Type t, 4V
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer Soprema,Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON-US 00000
(819)478-2400 Ext 3327
memathieu@s.oprema.ca
Authorized Signature Marc-Etienne Mathieu
memathieu@sqprema.ca
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1688 lean-Berchmans-Michaud
Drummondville,NON-US 00000
(819)478-2400 Ext 3327
memathieu@soprema.ca
Quality Assurance Representative Jean-Francois Cote,Ph.D.
Address/Phone/Emall 1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluatlon Report from a Florida Registered Architect o
Florida Professional Engineer.
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J. M. Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/16/2017
Validated By John W. Knezevich, PE
of 3 1/5/2016 3:08 PM
J"
loridaBuildin;Code Online htip://www.11oridabuildiung.org/pr/pr app_dtl.aspx?pamTn=wGEVX...
V Validation Checklist-Hardcopy Received
Certificate of Independence -22569 R11 COI 21115 01 C01 Nl§rmingq g
Referenced Standard and Year(of Standard) Standard
ASTM D1970
ASTM D6163
ASTM D6164
FM 4474
FRSA/TRI April 2012 (044-12)
TAS 103
TAS 110
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/15/2015
Date Validated 10/19/2015
Date.Pending FBC Approval 10/21/2015
Date Approved 12/15/2b15
Summary of Products
FL i# Model,Number or Description
(Name f
2569.1 Soprema Roof Self adhering roof underlayments
Underlayments
Limits of Use Installation instructions
Approved for use in ffVFIZ: No FL2569 R11 Ii 2015 10 FINAL ER 50PREMA CA UNDERLA`:'P
Approved for use outside P11-1-1-0-df
HVHZ:Yes Verified By: Robert Nieminen, P.E. PE-59166
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-90 Evaluation Reports
Other, 1.) Refer to ER Section 5 for EI-2569 R11 AE 2015 10 FINAL ER SOPREMA.CA UNDER!4Y
Limits of Use.2.)The design pressure RiLpi `'
noted herein pertains to underiayment Created by Independent Third Party: Yes
systems used:beneath adhesive-set tile'
systems.Refer to ER Section 5.6.4 for
details.
Bads Ir(�rexti
Contact Us,:1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487=1824
The State of Florida is an AA/EEO employer. wraht 20073013 State of Florida.::PrNBQt Statement:;�ssjbilky Statement R
tinder Florida law,email addresses are pubiic records.If you do not want your e-mail address released in response to a public-records req
of'3 " 1/5/2016 3:08 PM
Florida Building Code Online http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVX..:
electronic mail to this entity.Instead,contact the office by phone or by traftonal mall.If you have any questions,please contact 850.487.
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must proVide the Department wi
they have one.The emails provided may be used for official communication with the licensee.Howeveremail addresses are public record.Il
supply personal address,please provide the Department with an email address which can be made available to the public.To determine I yo
Chapter 455,F.S.,please click ere,.
Product ApprovalAcoepts:
cCkstk
of 3 1./5/201-6.3:08 PM
~ �
EXTERIOR RESEARCH&DESIGN,I.I.C.
{ertffiu,teqyAbthm/izatiom#9503
� ���
��� . 353CHR�T#\NSTREE�UN�#13
N ��� �0
OXFORD,CTO647
PHONE:(203)262'9245
FAX:(203)362'9243
EVALUATION REPORT
Soprema,Inc. . Evaluation Report S18010.06.09-R9
1640 rue Haggerty, FL2569-Rll
DnxmmondvY|he,QudbecJJ[5PQ Date wfIssuance:06/15/2009
Canada Revision 9:10/12/2015
ScQpEO
This Evaluation Report.is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in.the State of Florida, The documentation submitted has been reviewed by Rob rtNieminen,
P.E. for use oft6e product under the FloridaBuilding Code and Florida Building Code, Residential Volume. The
prpdm#s
described herein have been evaluated for compliance with the 5m Edition (2014) Florida Building Code
'sections noted herein.
PsSoRIMom: 8opnemma RowfUndmrlsymeots
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
' herein.
CONTINUED COMPLIANCE: This Evaluation Report isvalid until such time asthe named producL(s)changes,therefenenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation' Report 'by the named client constitutes agreement to notify Robert 0|eminen, P.E. If the product
changes urthe referenced Quality Assurance documentation changes. Trinity/ERDrequires acomplete review ofthis
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT.The Evaluation Report number preceded hythe words 'Trinity/EHDEva/uated" may bodisplayed |n
adveYtisin8Uwenyture' Ifany portion ofthe Evaluation Report isdisplayed,thenitshe8badonein"itsentirety.
Imspccn,JOm:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its.distributors and shall be available for inspection at theJob site.at the request of the Building Official.
This Evaluation Repo�cons�mofpa��1throu�h7'
Prepared by:
-
»�
Robert J.M.Niermivew,P.E. The*�imim°=~°=mm was.��nze*byRobert
F���K���n�mNo�U��y�r���cA�mEzs�/ � ������� '"~==~����=°��=�"�"
` ' Signed, "=�"���~w�"�*�/mthe
``''� ,�a�.^w"=/�~m�"�,=^�m"==*`wm
co�pp^nowo��osm�opm�, �
1. Trinity IE8odoes not have, nor does itintend uzacquire orwill it aom|ne, afinancial interest|nany company manufacturing o,
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nleminmn,P.s.does not have nor will acquire,afinancial interest inany Company manufacturing ordistributing products for
which theeua|umtionreports are being issued.
4. Robert Nieminen,0,.E.does not have,nor will acquire,a financial Interest in any other entity involved in-the approval process of the
' Pmdo#.
� TmomabundmAo� evaluation. Neither )sRD � � nmP.E.
xRv�� m|eoen,pan� �
|n�nywa �eoegmnerqf8eoo/dfvrvny
project onWhich this Evo|uatiunRepon,nrprevious versions thereof,is/was used for permitting urdesignguidance unless retained
specifically for that purpose.
'
'
TRIM 3 'ER i')-
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
fallowing sections of the Florida Building Code through testing in accordance with the following-Standards.
Compliance is-subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
STANDARDS:
Section Property Standard Year
1504.3:1 Wind Resistance FM 4474 2004
1507.2.4,1507.2.8, Physical Properties ASTM D1970 2009
1507.2.9.2,1507.4.5.1,
1507.5.3,1507.7-3
1507.11.2 Physicai Properties ASTM D6163 2006
1507.11.2 Physical Properties ASTM D6164 2005.
1523.6.5.2.1 Physical Properties TAS 103 1995
TAS'110 Accelerated Weathering TAS 110 2000
1507.3..3 Installation Practice FRSA/TRI April 2012(04-12) 2012
3. REFERENCES:
Enti Examination Reference Date
ERD(TST6049) ASTM D1970/TAS 110 2968.05.04-2 05/14/2004
ERD(TST6049) Physical Properties 2757.02.05 02/03/2005
ERD(TST6049) ASTM D1970/TAS 110 2974.03.0$=2 05/17/2005
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) Wind Resistance 2779.11.05-R1 04/18/2007
ERD(TST6049) TAS 103/TAS 110 S7120.11.07-2 11/02/2007
ERD(TST6049) ASTM D1970/TAS 110 S13190.02.09-R1 04/01/2010
ERD(TST6049) ASTM D1970/TAS 110 S31370.03.10-1-RI 04/07/2010
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.10-R1 09%09/2010
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.09-112 10/05/2010
ERD(TST6049) ASTM D1970 S37210.11.11 11/09/2011
ERD(TST6049) ASTM D1970 540540.02.13-1 02/19/2013
ERD(TST6049) Physical Properties/Tensile Adhesion 543530.02.14-1 02/21/2014
ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015
M-D(CER1592)' HVHZ Compliance 09-1005.02 11/04/2010
M-D(CER1592) HVHZ Compliance 13-0530.02 11/27/2014
ICC-ES(EVL2396) 2012,2009 and 2006 IBC Compliance ESR-1524 10/01/2014
PRI(TST5878) Physical Properties SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 05/29/2015
UL,LLC(QUA9625) Quality Control Service Confirmation Exp.10/16/2017
4. PRODUCT DESCRIPTION:
4.1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced, SBS modified bitumen roof
underlayment.
4.2 Lastobond Shield is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof
Underlayment available in two widths;36 and 45 inch.
4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment;available in 3.3 ft x 65 ft rolls.
Exterior Research and Design,LLG Evaluation Report 518010.06.09-R9
Certificate ofAutboriwtion'#9503 1.2569-1111
Revision 9:10/12/2015
Page 2 of 7
, »
' l �
�����
���xx�
4.4 Lastobond Shield HT is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified
`
bitumen roof undedayment
4.5 Lastobond Pro HT-m is a seK-adhering, woven polyethylene surfaced, SBS modified bitumen roof
uudedaymentavailable iotwo widths;36and 45inch.
4.6 Lamobond Pro HT-S is self-adhering, woven polyethylene surfaced, high temperature, SBS modified
bitumen roof undedayment
4.7 Lastobpnd. 195 is a self-adhering, glass-mat reinforced,. sand-surfaced, SRS modified bitumen roof
undedayment
4.8 Lastobond is a self-adhering, glass-mat reinforced, sand'svdaced. SSS modified bitumen roof
under|ayment'
4'9 Lastubond Ecu is g self-adhering, glass-mat reinforced, sond-surfaced SIBS modified bitumen roof
' undedoyrnent.
4.10 Lagoboind Smooth 5eo{ MT'|s u self-adhering, glass-net reinforced, fi|uo`surfacsiSBS modified bitumen
noofundedayment. '
4.11 RESISTO LB1236 is m self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
under|aymentwith a36-inchsheet width.
4.1I Pdme5ourceGrip-Rite Eove&Valley Protector isaxw!f-adhedng,g)oos'matreinforced,sand'ourfaced^SBS
modified bitumen roof undpdayment,with a3G-inohsheet width.
4.13 RESISrO um1244 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
ondedaymont,with a44-inchsheet width.
4.14 Colphene FR GR is a self-adhering, fiberglass reinforced, granule-surfacod, SBS modified bitumen roof
undedayment.
4'15 Uni|ay (e) is mechanically attached, polyester reinforced' gmmu|e-surfaoed^ SBS modified bitumen roof
under|ayment.
S. 1jrmnn'noms: '
5.1 This is a building code evaluation. Neither Thnby(ERn nor Robert mleminen' P.E. are, in any ' the
Designer ofRecord for any project-onwhich this Evaluation Report,
-orpn�iousversions thereof, im4maa
usedfor pe,miuin0ordesign guidance unless retained spedficaUyfor thatpurpose.
5.2 This Evaluation Report ixnot for use inthe HVHZ.
5.3 Fire Classification bnot part ofthis.report; refer to-current Approved goofing Materials Directory for fine
'
ratings ofthis product.
` 5.4 Soprema Roof Unclierlayments may biff used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If notlisted,a request may be made to the AHJ for approval
based on this evaluation combined with supporting data for the prepared roof covering..
5.5 Allowable roof covers applied atop the under|aymantsare follows:
TAKE 1: ROOF COVER OPTIONS
UnderlayTent Asp.halt Nall-On Foam-on Metal Wood Shakes& Slate
-Shingles Tile rile Shingles
Yes
Lastobond TU HT Yes Yes Yes Yes Yes
See S.SA
Yes No No No Yes Yes
RESISTO SA SMOOTH PLY 40
Lastobond Shield HT/Pro HT-S Yes No No Yes Yes Yes
Lastoband/Lastobond 1-95 Yes No No No Yes Yes
'
'
Exterior Research and Design,LILc Evaluation Report s1ow1o.0aoe-Ry
oeWficatoofAmthmizo6on#9503 FL2569-Rll
` Revision 9:20112/2015
'
Page amz
Y ,
Yy4
TABLE 1: ROOF COVER OPTIONS
Underlayment Asphalt Nail-On Foam-On Metal Wood Shakes& Slate
Shingles Tile. Tile Shingles
Lastobond ECO /RESISTO
LB1236,Grip-Rite Eave&Valley Yes. No No No Yes Yes
Protector/RESISTO LB1244
Lastobond Smooth Seal HT Yes No No Yes Yes Yes
Colphene FR GR Yes Yes Yes See 5.5.1 No' Yes Yes
' Yes Yes
Unilay(e) Yes Batten Only See 5.5.1 NO No No
5.5.1 "Foam-On Tile" is limited to.use of the following adhesives unless tensile adhesion/long term aging data
from an accredited testing laboratory is provided.
Underlayment Adhesive(s)
Lastobond TU HT 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)or Dow Chemical TileBond"'Roof
Tile Adhesive(FL717)
Colphene FR GR 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
Unilay(e) I 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
5.6 Allowable substrates are noted below:
5.6.1 Direct-Bond to Deck: .
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond, Lastobond 195,. Lastobond ECO, RESISTO LB1236, Grip-Rite Eave &
Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal HT applied to:
Plywood;ASTM D41 primed plywood; OSB;ASTM D41 primed OSB;Southern Yellow Pine;ASTM D41
primed Southern Yellow Pine;ASTM D41 primed structural concrete.
Colphene FR GR applied to:
i Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete.
Note:
While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends
priming with Elastocoi Stick or Elastocol 600c if the final roof cover is not slated for installation within
24 hours.
Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to
installation of the self-adhering underlayment.
5.6.2 Bond-to-Insulation:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond,. Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave &
Valley Protector,RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied-to.:
> Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam-on tile systems(Lastobond TU HT only),insulation attachment shall be designed by a qualified
design professional and installed based on testing of the insulation/underlayment system in accordance
with FM 4474,Appendix D or TAS 114,Appendix J.
Exterior Research and Design,LLC Evaluation Report 51$010.06.09-119
Certificate ofAuthor.kaffon#9503 FL2569-R21
Revision 9,10/12/2015
Page 4 of'7
TRINI L-JR.
5.6.3 Bond to Mechanically Attached Base Laver:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave &
Valley Protector,RESISTO LB124.4,Lastobond Smooth Seal HT or Colphene FR GR applied to:
➢ ASTM D226,Type I or II felt;5opra-G;Modified Sopra-G.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam-on tile systems (Lastobond TU HT only),
base layer shall be attached in accordance with FRSA/TRi April 2012(04-12).
.5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRE April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems;where
the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment
systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam-ori tile applications.
Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has
already been applied). Refer to FBC 1609 for determination of design wind pressures.
5.6.4.1 Maximum Design Pressure=-45.0 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional)Elastocol Stick or Elastocol 6000
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
5.6.4.2 Maximum Design Pressure=-67.5 psf.
'Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: Elastocol 600c
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
5.6.4.3 Maximum Design Pressure=-6Q0 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin
caps(FBC 1517.5.2)spaced 6-inch o.c.at the 4-inch laps and.6-inch o.c.in three,equally
spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered
5.6.4.4 Maximum Design Pressure=-90.0 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Underlayment: Unilay(e) mechanically attached with Soprafix Polymer Batten Bar (PB'8) or Soprafix
Metal Batten Bar(MBB)with Soprema#15-EL fasteners spaced 6-inch o.c.within the 5-
inch wide, self-adhering side laps. End laps are 6-inch wide and sealed using either
heat-welding or hot-air welding techniques.
5.7 Exposure Limitations:
Lastobond, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236, Grip-Rite Eave &
Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-days after installation.
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond
Pro HT--S shall not be left exposed for longer than 90-days after installation.
Lastobond TU HT or Colphene FR GR or Unilay(e)shall not be left exposed for iongerthan 180-days.after
installation.
Exterior Research and Design,LLC. Evaluation Report S18010.06.09-R9
Certificate ojAdthorkadon iH5M FL2569-R31
Revision 9:10/12/2015.
Page 5 of 7
IN111Y B
6. INSTALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick or
Elastocol'600c(if applicable).
6.3 Lastobond TU HT Lastobond Shield Lastobond Pro NT-N,RESISTO SA SMOOTH PLY 40,Lastob6nd Shield
n Lastobond Pro HT-S,Lastobond Lastobond 195 Lastobond Eco Lastobond Smooth Seal HT RESISTO
LB1236,Grip-Rite Eave&Valley Protector RESISTO LB1244 or Colphene FR GR:
6.3.1 Shall be installed In compliance with the requirements for ASTM D1970 underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 Non-Tile Applications:
While priming is optional,Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final
roof cover is not slated for installation within.24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release.film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the
membrane tight..Firmly roll the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
Inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps
shall be sealed using either heat-welding or hot air welding techniques.
When installing at slopes above 8:12,Soprema recomrriends back-nailing in the overlap area-at the top of
the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place,working from the center of the valley or ridge in
each direction: For valleys,apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications(Lastobond TU HT or Colphene FR GR onlyl:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1-herein, using the
instructions noted above as a guideline.
For foam-on tile applications, reference is-made to Section•5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRE April 2012(04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
6_4. Unila e:
6.4.1 Non-Tile Applications or Nail-On,Battened Tile Applications:
Reference is made to Table 1 herein and FRSA/TRI April 2012(04-12)Installation Manual(if applicable).
Apply sheet parallel to the roof edge and, starting at the eave with the selvedge-edge upslope,
mechanically attach the 5-inch wide selvedge-edge to the wood deck with nails and tin caps or round cap-
nails spaced 36-inch o-c. Apply the second course in a water-shedding manner with self-adhering side-
laps. Vigorous hand or motorized roller pressure is applied to the self-adhering laps to ensure a watertight
application.
Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course
below. All over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques.
Exterior Research and Design,LLC. Evaluation Report S18010.06.09-119
Certificate ofAuthorlsadon#9503 F.L2569-Ril
Revision 8.:10/12/2015
Page 6 of 7
TRIM H 9a i E#'aD
Tile(if applicable)shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment:
6.4.2 Foam-On Tile Applications:
Reference is made.to FRSA/TRl April 2012 (04-12) Installation Manual,Table 1 herein and Section 5.6.4.4
herein.
Apply sheet parallel to the roof edge and, starting at the eave with the selvedge-edge upslope,
mechanically.attach the 5-inch wide selvedge-edge to the wood deck Soprafix Polymer Batten Bar(PBB)or
Soprafix Metal Batten Bar (MBB) with Soprema #15-EL fasteners spaced 6-inch o.c. Apply the second
course in a water-shedding manner with self-adhering side-laps. Vigorous hand or motorized roller
pressure is applied to the self-adhering laps to ensure a watertight application.
Vertical seams should be 6-inches and staggered not less than 1-ft fiom vertical seams in the course
below. All over-granule end-laps shall be sealed using either.heat-welding or hot-air welding techniques.
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to .the
underlayment.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the.installation of
this.product.
�. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for information on plants coverer! under Rule 61620-3 QA
requirements.
9. QUALITY AssURANCE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation.Report 518010.06.09-R9
Certificate ofAuthorizatlon.0503 FL7S69-R21
Revision 9:10/12/2015
• Page 7'of 7