HomeMy WebLinkAboutProduct Approval (5) 7/8/2016 Florida Building Code Online
�•':,� a ��'�� -e � $x," @F� a F >; c�i'.'-=:;•-
:'a;p Y BCIS Home` Lo In i User Registration Hot Topics Suhmit Surcharge Stas&Facts Publications i FBC Staff BCIS Site Ma i Links i Search
.1oflltj�Digpa .ne.. 9 9 i P r9 p .
Businesti .
r
Prafessi gal -s Product Approval
USER;Public User
Product Aooroval Menu>Product or Aoolicatlon Search>A°olication List>Application Detail
mm =6j. FL# FL7006-R9 13t t g ( fi
` Y Application Type Revision ( ;.
Code Version 2014 } f :y`k �'•'' �r "'
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer IKO Industries, Ltd
Address/Phone/Email 40 Hansen Road South
Brampton, NON-US L6W 3114
(708)496-2800 Ext 200
rmetzD01@tampabay.rr,com
Authorized Signature Robert Metz
rmetzOOI@tampabay.rr.com
Technical Representative Bob Metz
Address/Phone/Email REMCO of Pinellas
456 Avila Circle NE
Saint Petersburg, FL 33703
(727) 776-5261
rmetzOOI@tampabay.rr.com
Quality Assurance Representative Don Shaw
Address/Phone/Email IKO Industries LTD
120 Hay Rd.
Wilmington, DE 19808
(717) 579-6706
don.shaw@iko.com
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Certification Mark or Listing
Certification Agency FM Approvals-CER
Validated By Locke Bowden
Validation Checklist- Hardcopy Received
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 modified to 110 mph, 2009
ASTM D3462 2009
ASTM D7158 Class H 2008
ASTM E108 2007
Equivalence of Product Standards
Certified By
httpsJ/www.floridabuilding.org/pr/pr appdtl.aspk?param=wGEVXQwtDgse7mYBd2b3K6mXtoZLhNVX122Np170J1E%3d 1/3
7182016 Florida Building Code Online
Product Approval Method Method 1 Option A
Date Submitted 06/26/2015
Date Validated 06/30/2015
Date Pending FBC Approval
Date Approved 07/06/2015
Summary of Products
FL 0 Model,Number or Name Description --�
7006.1 Cambridge, Cambridge HD and CRC Laminated architectural fiberglass asphalt shingle
Biltmore AR manufactured at IKO's Kankakee, IL; Hawkesbury, Ont.;
Wilmington, DE; Sylacauga,AL and Toronto, Ont. plants
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL7006 R9 C CAC FM Letter-ASTM d3161 letter- 4-15-
Approved for use outside HVHZ:Yes 2015 .odf
Impact Resistant:N/A FL7006 R9 C CAC FM Letter-ASTM d3462 letter- 5 6
Design Pressure: N/A 15.odf
Other: FL7006 R9 C CAC FM Letter-ASTM E 108 letter- 5 3
15 .adf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL7006 R9 IT IKO-133-02-01 Letter-Installation
Instructions for FBC FL7006.pdf
Verified By: Duc T Nguyen 65034
Created by Independent Third Party: No
i Evaluation Reports
Created by Independent Third Party:
7006.2 Hip and Ridge 12 Cap fiberglass This is a 12"x 12"fiberglass asphalt shingle used to cover
shingles the hip and/or ridge of an asphalt shingle roof system
i manufactured in Toronto,Ont.and Brampton, Ontario
Limits of Use Certification Agency Certificate
Approved for use In HVHZ:Yes 9L7006 R9 C CAC FM Letter-ASTM d3161 letter- 4-15- j
Approved for use outside HVHZ:Yes 2015 .odf 1
Impact Resistant: N/A FL7006 R9 C CAC FM Letter-ASTM d3462 letter- 5 6
Design Pressure: N/A 15.Pdf
Other: )L7006 R9 C CAC FM Letter-ASTM E 108 letter- 5 3
15 .odf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL7006 R9 II Hip and Ridoe Can Shingle Installation
a,= Iristructions.pdF
FL7066 R9 II IKO-133-02-01 Letter-Installation
Instructions for FBC FL7006.1)df f
Verified By: Duc T Nguyen PE 65034 i
Created by Independent Third Party: No
I Evaluation Reports
Created by Independent Third Party:
7006.3 Leading Edge Plus Asphalt Shingle One piece fiberglass asphalt shingle used as a starter strip at
l Starter Strip the bottom of a roof system manufactured in Brampton and
Hawkesbury,Ontario plants
Limits of Use Certification Agency Certificate l
Approved for use In HVHZ:Yes I FL7006 R9 C CAC FM Letter-ASTM d3161 letter- 4-15-
Approved for use outside HVHZ:Yes 2015 ,pdf
Impact Resistant:N/A FL7006 R9 C CAC FM Letter-ASTM d3462 letter-5 6
Design Pressure: N/A 15.odf
Other: FL7006 R9 C CAC FM Letter-ASTM E 108 letter- 5 3
15 .odf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL7006 R9 II IKO-133-02-01 Letter- Installation
i Instructions for FBC FL7006.pdf
FL7006 R9 H Roofing-Products-Leading-Edge-Plus- I
Application-EN(1).pdf I
Verified By: Duc T Nguyen PE 65034
Created by Independent Third Party: No
fEvaluation Reports
Created by Independent Third Party:
7006,4 J Marathon 25 AR, CRC Superglass 3 tab fiberglass asphalt shingle manufactured at IKO's
hUp://www.floridabLildirig.org/priprapp dtl.aspx?param=wGEVXQwtDgse7mYBd2b3K6mXtoZLhN\.XI22Npi7oJlE%3d 213
7/812016 Florida Building Code Online
M25AR Brampton,Ontario, Hawkesbury Ont.,Toronto, Ont.;
I Sylacauga,AL and Kanakakee,IL plants
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL7006 R9 C CAC FM Letter-ASTM d3161 letter- 4-15-
Approved for use outside HVHZ:Yes 2015 .Ddf
Impact Resistant: N/A FL7006 R9 C C AQ FM setter-ASTM d3462 letter- 5 6
Design Pressure:N/A 1S.Ddf
Other: FL7006 R9 C CAC FM Letter-ASTM E 108 letter- 5 3
15 .odf
Quality Assurance Contract Expiration Date
12/20/2020
Installation Instructions I
FL7006 119 II IKO-133-02-01 Letter-Installation I
Instructions for FBC FL7006.pf 1
Verified By: Duc T Nguyen 65034
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
' WackPie>:f
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEo employer.Copyright 2007-2013 State of Florida.::Privacv Statement::Accessibility statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have
one:The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter
455,F.S.,please click here.
Product Approval Accepts:
Credi>:Card' .
Safe
haps!/www.11oridabuilding,org/pr/pr app o.aspx?param=wGEVXQwtDgse7mYBd2b3K6mXtoZLhNVX122Npl70J1Ea/aid 313
1
<,FM Approvals
FM Approvals Wsmba (if*P F.-V Gb)hal Liz;•;
1151 Boston-Providence Turnpike
P.O.Box 9102 Norwood,MA 02062 USA
T:781762 4300 F:781 762 9375 www.fmapprovals.com
May 3,2015
Mr.Donald Shaw
IKO Industries,Ltd.
40 Hansen Road South
Brampton,Ontario L6W 3H4
Canada
Customer ID: 1000000686
Subject: IKO Industries Ltd.'s FM Approved asphalt roof shingles
Dear Mr. Shaw,
This letter is being written following in regards to your recent inquire regarding verification of the ASTM
D3161 testing of IKO Industries Ltd's asphalt roof shingles. TKO's shingles that are FM Approved have
been tested in accordance with ASTM.D3161 (reports 3040947 and 3038510).
FM Approvedproducts:
]EKO Ttulustiries°ltd::':-; Crowne Slate,Cambridge;Hip&Ridge 12,Marathon 25 AR,Marathon
Ultra AR,Cambridge IR,Leading Edge Plus,Cambridge HD,Marathon .
25,Hip&Ridge Plus,Dynasty with ArmourZone
;.Cali t tion CuirpbraEpri IuG:°;... ,;: Biltmore,Hip&Ridge 12(CRC),Superglass 25 M AR,Superglass
Ultra AR,(CRQ Hip&Ridge Plus
Please be advised that shingles noted above tested to previous versions of ASTM D3161 continue
to meet the test criteria of the current version of ASTM D3161.
If you have any questions please do not hesitate to contact me.
Very truly yours,
David L.Alves Phillip J. Smith
Senior Engineer-Materials Group Principal Engineer-AVP
FM Approvals FM Approvals
1151 Boston-Providence Turnpike
Norwood,MA 02062
T: 781 255 4856
E:david.alves@fmapprovals:com
€X C C <1>
FM ,�
CONSTRUCTION MATERIALS
TECHNOLOGIES
March 30, 2015
IKO Industries, Ltd
120 Hay Rd.
Wilmington, DE 19809
Re: FBC FL7006
Sir(s),
PRI Construction Materials Technologies has completed a technical review and attached sealed shingle
instructions in compliance the 2014 Florida Building Code.
This review was completed based on the receipt of following evidence from IKO Industries, Ltd:
1) 'IKO Shingle Application Instructions—3-Tab Shingles
(EN-3Tab_Appins-8AGXEFS-2012-11 reformatted 2013-02-rev07/13-Florida)
2) IKO Laminated Shingles Application Instructions
(EN-Laminated,,Appins_8TTEFS-2012-04 reformatted 2013-02-rev07/13-Florida)
3) IKO Hip and Ridge 12 Application,Instructions
(EN-HipandRidge12-3HRTri-2013-08_reformatted 2013-08)
4) IKO Leading Edge Plus Shingle Application Instructions
(EN-3LEP-Tri-2012-06—reformatted 2013-03)
5) ASTM D3161 Test Report(FM Approvals Project No.3040947)
The attached instructions should be used in conjunction with the published manufacturer's application
instructions and applicable code. In the event the instructions conflict, these instructions shall govern.
Statement of Independence:PRI Construction Materials Technologies and/or Duc T.Nguyen, FL P.E.do not
have nor plan to acquire a financial interest in any company manufacturing or distributing products for which
the test reports are issued.
Signed: fir` �' � Signed: �' Au-
Brad
9 v t
Grcybo sKl Duc T.N en
Managing rector Florida Reuse Professional Engine r
P.E.Number:65034
Date: April 30, 2015 Date: April 30;2015
Attachments: A) IKO Shingle Application Instructions-3-Tab
8) IKO Laminated Shingles Application Instructions
C) IKO Hip and Ridge 12 Application Instructions
D) IKO Leading Edge Plus Application Instructions
IKO-133-02-01
PRI Consoucdon Materials Technologies,LLC.6412 Badger Drive Tampa,FL 33610 Tel:813.621.5777 Fax:813621-5840 e-mail:matedalstestng@pdcmt.com WebSite:htlpJANw;w.pricntcrm
IKO
Installation Instructions for
Asphalt Shingles
Page 2 of 5
IKO Shingle Application Instructions — 3-Tab Shingles
(ASTM D3161, Class F—IKO Marathon 25 AR and CRC Superglass M25AR)
NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED
APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION
CONFLICT,THESE INSTRUCTIONS WILL GOVERN.
ROOF DECK: Solidly sheathed and fastened deck conforming to 2014 FBC.
UNDERLAYMENT:Applied in accordance with building code requirements.For areas where the roof slope is
less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code
requirements,the first sheet overlapping the eave protection by 19",followed by full 36"widths overlapping
each preceding course by 19"or other Approved underlayments in accordance with the qualified application
instructions. For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of
underlayment laid parallel to the eaves;with 2"horizontal laps and 4"end laps. Apply metal drip edges on top
of any underlay along rake edges and directly to the deck along eaves in accordance with building code
requirements.
NAILING: Use galvanized(zinc coated)roofing nails, 11 or 12 gauge,with at least 3/8"diameter heads,long
enough to penetrate through plywood or 3/4"into boards. Use 4 nails per shingle placed 6-1/8"above the butt
edge,approx. T'and 13"from each end and 1/2"above each cutout. Drive nails straight so that nail head is
'flush with, but not cutting into shingle surface.
NAILING ON STEEP SLOPES:For steep slopes of 21"per foot(60°)or more,use 6 nails per shingle placed
as shown below. Ensure that no nail is within 2"of a joint/cutout of the underlying shingle. Seal down each
shingle at time of application with three 1"diameter(approx.size and thickness of a quarter)spots of asphalt
plastic cement placed under the shingle 2" above the bottom edge and equally spaced along the shingle.
Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles
should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the
heat of direct sunlight.'
EXPOSURE: Installed shingles shall have a maximum average exposure of 5-5/8".
STEEP SLOPES-
'71
i~SEALING STRIP _'w •. s -
,I
NAILS f- NAILS
DO NOT NAILINTO dRABOVETHE-SEALING STRIP
PRI ConsWction Materials Technologies,I.I.C.6412 Badger Drive Tampa,FL 33610 Tel:813-621-5777 Fax:813621-5840 a mall:materialstesting@pricnItcom Website:httpJAvww.pricmtcom
IKO
Installation Instructions for
Asphalt Shingles
Page 3 of 5
IKO Laminated Shingles Application Instructions
(ASTM D3161, Class F—Cambridge,Cambridge HD, and CRC Biltmore AR)
NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED
APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION
CONFLICT,THESE INSTRUCTIONS WILL GOVERN.
ROOF DECK: Solidly sheathed and fastened deck conforming to 2014 FBC.
UNDERLAYMENT:Applied in accordance with building code requirements.For areas where the roof slope is
less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code
requirements, the first sheet overlapping the eave protection by 19",`followed by full 36"widths overlapping
each preceding course by 19"or other Approved underlayments in accordance with the qualified application
instructions. For areas where the roof,slope is 4" per foot or greater, cover the deck with one ply of
underlayment laid parallel to the eaves,with 2"horizontal laps and 4"end laps. Apply metal drip edges on top
of.any underlay along rake edges and directly to the deck along eaves in accordance with building code
requirements.
NAILING:Use galvanized(zinc coated)roofing nails, 11 or 12 gauge,with at least 3/8"diameter heads,long
enough to penetrate through plywood or 3/4"into boards. Use 4 nails per shingle placed in the nail line 7-3/8"
below the top edge, approx. 1"and 13"in from each end. Drive nails straight so that nail head is flush with,
but not cutting into shingle surface.
NAILING ON STEEP SLOPES: For steep slopes of 21"per foot(60°)or more,use 6 nails per shingle placed
as shown below. Ensure that no nail.is within 2"of a jointicutout of the underlying shingle. Seal down each
shingle at time of application with three 1"diameter(approx.size and thickness of a quarter)spots of asphalt
plastic cement placed under the shingle 2"above the bottom edge and equally spaced along the shingle.
Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles
should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the
heat of direct sunlight.
EXPOSURE: Installed shingles shall have a maximum average exposure of 5-7/8".
NAILING=STEEP SLOPES APPOCATIQH
usesix nails as stimn.
t
7 3M"
• r_ NAIL LINL
.NAILS CEMENT
PROPER APPLICATION REQUIRES THAT THE NAILS PENETRATE BOTH TIJE OVER AHfY UNDERLAY PQRTIONSOFTHE SHINGLE
PRI Construction Materials Technologies,LLC.6412 Badger Drive Tampa,FL33610 Tel:813-621-5777 Fax:813-621-5840 a-maU:materialstestng@pricmt.com WebSite:http1&ww.pdantcom
IKO
Installation Instructions for
Asphalt Shingles
Page 4 of 5
IKO Hip and Ridge 12 Application Instructions
(ASTM D3161,Class F—IKO Hip and Ridge 12)
NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED
APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION
CONFLICT,THESE INSTRUCTIONS WILL GOVERN.
Cut hip and ridge shingles into thirds, using the perforation marks as a cutting guide. These shingles are
designed for a 51/8"(130 mm)exposure. (For a neater appearance,the top of each side of each piece has
been factory trimmed on a 1"(25 mm)taper(see drawing).Bend each piece over the hip or ridge,and nail 5
5/8" (143 mm)above the butt edge 1" (25 mm) in from each edge,exposing each piece 5 118"(130 mm).
Apply hip pieces starting at the lower end of the hip, working up toward the ridge. On hip roofs, apply ridge
pieces starting at each end, meeting in the middle. On gable roofs, apply ridge pieces starting at the end
opposite to the prevailing wind direction and continue to the other end. Note:To obtain a three-dimensional
effect,(which is recommended,but not required),apply hip and ridge shingles double thickness bystacking 2
.pieces on top of one another,the lower piece extending about 3/4"(19 mm)further than the top piece(see
diagram).The final shingle should be set in cement,and the exposed nail heads of the final shingle should be
covered with cement. Prior to application in cold weather,storing the shingles in'a heated area will allow for
easier bending.
NOTE:SHINGLES MUST BE APPLIED PROPERLY.THEYARE DESIGNED FOR USEAS HIP AND RIDGE
SHINGLES ONLY,AND SHOULD NOT BE USED FOR ANY OTHER APPLICATIONS.WE ASSUME NO
RESPONSIBILITY FOR LEAKS OR DEFECTS RESULTING FROM POOR APPLICATION OR FAILURE TO
PROPERLY PREPARE THE SURFACE TO BE ROOFED OVER, OR FAILURE TO PROVIDE PROPER
VENTILATION IN ACCORDANCE WITH MINIMUM PROPERTY STANDARDS REQUIREMENTS.REVIEW
ALLAPPLICABLE BUILDING CODES,-MINIMUM PROPERTY STANDARDS,AND REQUIREMENTS PRIOR
TO APPLYING THESE SHINGLES USING THESE APPLICATION INSTRUCTIONS.
aro• f1"
R3 mms �r ias rhN
' ;AMC;iR
Ur � I
a We
(152M
PRI Construction Materials Technolagle%LLC.6412 Badger Drive Tampa,FL 33610 Tel:613-621.5777 Fax 613-621.5640 a-mail:matedatstes6ng@pricrnLcom WebSite:httP,/AVWW.pricmt.com
IKO
Installation Instructions for
Asphalt Shingles
Page 5 of 5
IKO Leading Edge Plus Application Instructions
(ASTM D3161, Class F—IKO Leading Edge Plus)
NOTE: THESE INSTRUCTIONS SHALL BE USED IN. CONJUCTION WITH IKO'S PUBLISHED
APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION
CONFLICT,THESE INSTRUCTIONS WILL GOVERN.
1. Apply any underlayment, eave protection,valley flashings, or drip edges to roof deck as required.
2. Each 39 318"x 131/4"(1000 mm x 336 mm)IKO Leading Edge Plus strip is perforated lengthwise for
separation into two(2)shingles.Take one IKO Leading Edge Plus strip and fold flat at perlbration to
separate.
3. Take one of the separated shingles 39 3/8"x 6 5/8"(1000 mm x 168 mm)and remove approximately
20"(500 mm). Install this shingle on the lower left corner of the roof deck, granule side up,with the
factory installed sealant adjacent to the eaves.The shingle should overhang the rake edge and eaves
by a nominal 1/4"(6 mm)minimum. Fasten the shingle to the roof deck with nails located 3"to 4"(75
mrn to 100 mm)from the eave edge and-1"(25 mm)in from each end.
4. Take the leftover 20"(500 mm)piece shingle.Rotate the piece and align it vertically up the rake edge
with the factory installed sealant adjacent to the outer edge of the roof.The shingle should overhang
the rake edge by a nominal 1/4"(6 mm)minimum. Fasten the shingle to the roof deck with fasteners
located 3"to 4"(75 mm to 100 mm)from the rake edge and 1"(25 mm)in from each end.
5. Repeat Steps 3—4 for the right lower comer of the roof deck.
NAILING: Use galvanized(zinc coated) roofing nails, 11 or 12 gauge,with at least
3/8"(9 mm)diameter heads, long enough to penetrate through plywood or 3/4"(20
mm)into boards. Use 4 nails per shingle placed 3"to 4"(75 mm to 100 mm)from
the save edge and approximately 1"and 13"(25 mm and 330 mm)in from each end.
6. Apply full-length IKO Leading Edge Plus shingles to the remaining eave edges of the roof deck.Install
the shingles granule side up with the factory applied sealant adjacent to the eaves. The shingles
should overhang the rake edge and eaves by a nominal 1/4"(6 mm)minimum.Fasten the shingles to
the roof deck with nails located 3"to 4"(75 mm to 100 mm)from the eave edge,4 nails per shingle.
7. Apply roof shingles as per the instructions printed on each product's package. Make certain the first
course of field shingle lies flush with the edges of the fastened IKO Leading Edge Plus. In this way,
the sealant on the IKO Leading Edge Plus shingles will adhere to the first-course field shingles and
help keep them from lifting in high winds.
PRI Construction Matedals Technologies,LLC.6412 Badger Drive Tampa,FL 3361D Tel:813-621STTT fax:813.621-580 e-mal matedalstesting@pdcmtcom WebSlle:http11www.pdamtcom