HomeMy WebLinkAboutWind Load Calculation *,F1F1MURvu6;1
WINDOW&DOOR
1000 Clint Moore Dr.#109 P:561-988-2444
Boca Raton,FL 33487 F:561-826-9180
Lie.#:CRC1330842 SOC131151529
Property Information Building Information
Owner: Joyce Hadley Wind Zone: 170 MPH.
Address: 6406 Doris Drive Exposure Category: C
Fort Pierce,FL 34951 Minimum Building Dimension: 48 ft.
Mean Roof Height: 14 ft.
JU Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 25 62 7 37.6 -40.8
2 Int 57 62 7 35.6 -38.8
3 Int 25 62 7 37.6 -40.8
4 Int 73 37 7 36.3 -39.5
5 End 36 37 7 37.8 -50.6
6 Int 36 37 7 37.8 -41.0
7 Int 73 37 7 36.3 -39.5
8 Int 36 36 7 37.8 -41.0
9 End 36 25 7 37.8 -50.6
10 Int 36 25 7 37.8 -41.0
W
RECEIVE®
AUG 2 9 2017
PERMITTING
St.Lucie County,FL
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.51h Edition(2014)Florida Building Code.
Page 1 of 1
F WINDOW & DOOR OPENING INFORMATION
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
PRODUCT APPROVAL REQUIRED OPENING MAXIMU MULTIPLE
OPENING (Location) IS THIS A PRODUCT ROUGH ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING MULLION SHUTTERS
NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF SIZE DIMENSIONS REQ Y/N
REQ Y/NMA
1 Int W 7/8"Lam' FL16177.1 70 70 37.6 40.8 5'_7/8X6'-3'4 25X62 Y N
2 Int W 1"Lami FL13010.1 67.50 67.50 35.6 38.8 72x76 57x62 Y N
3 Int W 7/8"Lami FL16177.1 70 70 37.6 40.8 5'_7/8X6'-3/4 25x62 Y N
4 Int W 7/8"Lami FL16736.1 60 60 36.3 39.5 74 X 63 73x37 N N
5 End W 7/8"Lami FL16177.1 70 70 37.8 50.6 51-7'0X6'_'/4 3607 N N
6 Int W 7/8"Lami FL16177.1 70 70 37.8 41.0 51.7/8X61_"4 3607 N N
7 Int W 7/8"Lami FL16736.1 60 60 36.3 39.5 74 X 63 7307 N N
8 Int W 7/8"Lami FL16177.1 70 70 37.8 41.0 51-7X61 3606 N N
9 End W 7/8"Lami FL16736.1 60 60 37.8 50.6 ]74 X 63 36X25 N N
10 Int W 7/8"Lami FL16177.1 70 70 37.8 41.0 51-7/8X61-3/4 36X25 N N
ti
c m ,
O :1
7 Z `i jabq
rn
r � 'st