Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Notice of Acceptance
M IAlb'11- 1 �� � i MIAbII-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 '1l T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) ! w-i«ir.miamidade.goN,/economv GAF 1 Campus Drive Parsippany, NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use,of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or materiallfails to meet the requirements of the applicable building code. II This product is approved as described herein, and has been designed to comply with the. Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Timberline Ultra HDO Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or loko, city, state and following. statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. �I TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an' ep, dorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ;1 ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County! Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the man shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 1,3-1104.12 and consists of pages 1 through 5 The submitted documentation was reviewed by Alex Tigera. ,turer or its distributors and NOA No.: 14-1022.21 Expiration Date: 04/22/18 Approval Date: 02/05/15 Page 1 of 5 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Asphalt Shingles Materials: Laminate Deck Type: Wood SCOPE This approves GAF Timberline Ultra HD® Shingles as manufactured by GAF described in Section 2 of this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Pry duct Description Specifications GAF Timberline Ultra HD® 13 1/4"x 393/8 " TAS 110 Fiberglas reinforced heavy weight asphalt roof Manufacturing shingle, with a laminate profile. Locations # 1, 2, 3, 4, 5, 6 MANUFACTURING LOCATION 1. Tampa, FL 2. Michigan City, IN 3. Baltimore, MD it 4. Ennis, TX 5. Myerstown, PA it 6. Tuscaloosa, AL EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Rep6rt Date Underwriters Laboratories, Inc. ASTM D 3462 02NK41809'1I 11/08/02 TAS 107 02NK4181 1'1I 11/11/02 TAS 107 03CA35209 " 10/17/03 ASTM D 3462 03NK26444 , 10/17/03 TAS 107 05CA42840 11/11/05 TAS 107 05CA475411 05/10/06 ASTM D3462 06CA10139 09/13/06 TAS 107 PRI Asphalt Technologies, Inc. TAS 100 ELK -108-02-0j 10/14/03 TAS 100 ELK -084-02-01 10/30/02 TAS 100 ELK -087-02-01 10/30/02 TAS 100 GAF -046-02=01 04/05/04, TAS 100 GAF -100-02-0'1 1(/16/08 ASTM D 3462 GAF -100-02-02 11/16/05 TAS 100 GAF -103-02-01 11/16/05' ASTM D 3462 GAF -103-02-02 11/16/05' NOA No.: 14-1022.21 Expiration Date: 04/22/18 Approval Date: 02/05/15 Page 2 of 5 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved -Roofing Materials Directory for fire ratings of this product. !I 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. INSTALLATION it 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail 'A', attached. 5. Nailing shall be in compliance with Detail 'B', attached. �I LABELING I Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. MIAMI-DADE COUNTY 'I BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by Building Official or Applicable building code inH order to properly evaluate the installation of this material. i! ;I NOA No.: 14-1022.21 Expiration Date: 04/22/18 Approval Date: 02/05/15 Page 3 of 5 DETAIL A COURSE LAYOUT Exposure NOA No.: 14-1022.21 Expiration Date: 04/22/18 Approval Date: 02/05/15 Page 4 of 5 1: DETAIL B -13-1/4" X 39-3/8" OVERALL DIMENSIONS AND NAILING PATTERN ,p Front Side (Maximum Slope 21:12) Tab Sealant r 1 2.. 1/2" Back Side GAF TIMBERLINE ULTRA HDO END OF THIS ACCEPTANCE 'C - Release Tape 3/8" NOA No.: 14-1022.21 Expiration Date: 04/22/118 Approval Date: 02/05/15 Page 5 of 5 i ,i II lip lip 6 fasteners — �2" - 72 i� S4 311 1. 5-4 - 6-4 i ',i EJ Front Side (Maximum Slope 21:12) Tab Sealant r 1 2.. 1/2" Back Side GAF TIMBERLINE ULTRA HDO END OF THIS ACCEPTANCE 'C - Release Tape 3/8" NOA No.: 14-1022.21 Expiration Date: 04/22/118 Approval Date: 02/05/15 Page 5 of 5 i 1. GAF 1 Campus Drive Parsippany, NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use ofl"construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -!Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade CouI'ty Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perforin in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke) modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke thin acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Fil orida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Seal -A -Ridge° Ridge Cap Shingles and GAF Timbertex° Premium Ridge Cap Shingles i LABELING: Each unit shall bear a permanent label -with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. I TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. l ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County;) Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufactiurer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 13-0306.08 and consists of pages 1 through 9. The submitted documentation' was reviewed by Alex Tigera. NOA No.: 14-0603:01 Expiration Date: 10/17/17 Approval Date: 12/22/16 Page 1 of 9 Iti1A1fMl•� i s , MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION i Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) j' wivw.miamidade.eov/cconomv GAF 1 Campus Drive Parsippany, NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use ofl"construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -!Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade CouI'ty Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perforin in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke) modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke thin acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Fil orida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Seal -A -Ridge° Ridge Cap Shingles and GAF Timbertex° Premium Ridge Cap Shingles i LABELING: Each unit shall bear a permanent label -with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. I TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. l ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County;) Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufactiurer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 13-0306.08 and consists of pages 1 through 9. The submitted documentation' was reviewed by Alex Tigera. NOA No.: 14-0603:01 Expiration Date: 10/17/17 Approval Date: 12/22/16 Page 1 of 9 ROOFING ASSEMBLY APPROVAL Category: R Iofing Sub -Category: Asphalt Shingles Materials 3 -Tab Perforated II Deck Tyne: Wood SCOPE This approves GAF Seal -A -Ridge® Ridge Cap Shingle and GAF Timbertex' Premium Ridge Cap Shingles as manufactured by GAF as described in this Notice of Acceptance. it PRODUCT DESCRIPTION Product Dimensions Test Specifications GAF Seal -A -Ridge® Ridge Cap 12" x 36" TAS 110 Shingle Manufacturing Location #1 GAF Timbertex® Premium 12" x 36" TAS 110 Ridge Cap Shingle Manufacturing Location #2 PRODUCTS MANUFACTURED BY OTHERS Product Product Size Description Loctite PL Roof & Flashing Adhesive Various Sealant MANUFACTURING LOCATION 1. Mobile, AL. 2. Mt. Vernon, IN. Pre fabricated with two perfc length of shin; Multi -layer prefa fiberglass reinfo perforations at'l., the shingle. I and ridge asphalt shingle ins at 12" o.c. along the 36" icated hip and ridge d asphalt shingle with o.c. along the 36" length of I! Manufacturer .1 jHenkel Corp. I; NOA No.: 14-0603.01 Expiration Date: 10/17/17 Approval Date: 12/22/16 Page 2 of 9 I ,I i EVIDENCE SUBMITTED Test Agency Test Identifier Test Name%Reyort Date Underwriters Laboratories, lnc, ASTM D3462 I ICA45079 03/21/12 ASTM D3462 12CA30878 02/01/13 TAS 107 11 CA45079 03/21/12 TAS 107 12CA38083 02/26/13 Fire Classification TFWZR21 06/13/14 I� PRI Construction Materials TAS 100 GAF 3380-02-01 11/06/12 Technologies LLC TAS 100 GAF -381;102-01 11/15/12 I LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. GAF Seal -A -Ridge® Ridge Cap Shingles and GAF Timbertex® Premium Ridgei,Cap Shingles shall be limited for use as hip and ridge cap shingles only. 3. Shall not be installed on roof mean heights in excess of 33 ft. 4. All products listed herein shall have a quality assurance audit in accordance with'the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. INSTALLATION 1. GAF Seal -A -Ridge® Ridge Cap Shingle and GAF Timbertex® Premium Ridge Cap Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 11 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Nailing for GAF Seal -A -Ridge® Ridge Cap Shingle shall be in compliance with Detail `A' attached. Exposure and course layout for GAF Seal -A -Ridge® Ridge Cap Shingle Ridge Cap Shingles shall be in compliance with Detail W. II 5. Nailing for GAF Timbertex® Premium Ridge Cap Shingles shall be in compliance with Detail `B' attached. Exposure and course layout for GAF Timbertex® Premium Ridge Cap Shingles shall be in compliance with Detail `B'. 6. A Miami Dade Approved ASTM C 920 Polyurethane Roof Sealant must be used in the application of GAF Seal -A -Ridge® Ridge Cap Shingles as specified in Detail A. 7. Henkel Corp. `Loctite PL Roof & Flashing Sealant' must be used in the application of GAF Timbertexm Premium Ridge Cap Shingles as specified in Detail B. NOA No.: 14-0603.01 Expiration Date: 10/17/17 Approval Date: 12/22/16 Page 3 of 9 LABELING Shingles shall be permanently labeled with the manufacturer's name and/or logo, city and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen below: MIAMI•DADE COUNTY 6 ,...8 1 BUILDING PERMIT REQUIREMENTS 1. Application for building Permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. j f MIAMI•DADE COUNTY Fj ...o ya NOA No.: 14-0603.01 Expiration Date: 10/17/17 Approval Date: 12/22/16 Page 4 of 9 3 Ste Three — Apply ride ca using 2 nails per piece 7" to 7-5/8" back from the exposed end and 1" () P PPY g P g P P P to 2" up from the edge !(see Figure 2 for location of nails). Use only corrosion resistant zinc coated steel or aluminum, 10-12 gauge, barbed, deformed or rings shank roofing nails with heads 3/8" (9.5mm) to 7/16" (12mm) in diameter. Nails should be long enough to penetrate at least 3/4" tjl9mm) into wood decks or just through plywood decks. Nails must be driven flush with the surface of the shingle. Over driving will damage the shingle. Raised nails will interfere with the wind resistance of the shingles. I Special Application Section: I For Cold Weather Application • In cold weather, warm GAF Seal -A -Ridge® Ridge Cap Shingles before bending. • When self-sealing is delayed due to cold weather, apply quarter -sized dabs, of an approved asphalt plastic cement (must conform to ASTM D4586 Type I or Type II) between ridge cap pieces and press firmly to insure good contact between pieces. i For High -Wind Zones • In high wind areas or for maximum wind resistance, apply a'/4" wide bead of a Miami Dade Approved ACTM C 920 Polyurethane Sealant to each ridge cap shingle parallel to the ridge 3/4" — 1" from the shingle edge. (see Figure 3). it Figure 3 For maximum wind:speed coverage under ltd, warranty, apply additional sealant as shown. See -Special Application Section for specific details. Para el alcance mdArno de velocidad de viento baja limitado garantia, aplica sellador adicional corno mostrado. Vea Secci6n Especial de Aplicaci6n para detatles especiftcos. i Pour to couverture, maArnum de Vitesse de vent sous limit6. la garanlie'; appliquer de 1'enduit d'etanchdite supptementaire comme indiqus. Voir la section sp6ciale d'application pour les d6tails specifiques. NOA No.: 14-0603:01 Expiration Date: 10/17/17 Approval Date: 12/22/,16 Page 6 of 9 i I I DETAIL A I GAF Seal-A-Ridge`s Ridge Cap Shingles Application Instruct I (1) Step One — Separate each piece of GAF Seal -A -Ridge® Ridge Cap Shingles int ridge cap shingle pieces at perforations (see Figure 1). Figure 1 �-•— Yz"(12mrn) (345 mm) � r 1 1, I I i three individual 6 2/3" Exposure (169 mm approx.) di 12, Porloratod (300 111P) 36; (914 mm) ,j (2) Step Two —Begin laying full ridge cap shingle with a 6-2/3" exposure beginning at the bottom of the hip or from the end of the ridge opposite the direction of the prevailing wind (see Figure 2). Figure 2 NOA No.: 14-0603.01 Expiration Date: 10/17/17 Approval Date: 12/22/16 Page 5 of 9 �I DETAIL B I GAF Timbertex° Premium Ridge Cap Shingles Application Instructions: (1) Step One — Separate each piece of GAF Timbertex® Premium Ridge Cap Shingles into three individual ridge cap shingle pieces at perforations (see Figure 1). it p Figure 1 ii {305rrim}30J"mrnj (30nirn} II erir. e i 14f(10: g".(2Q' d 1 1 -- �r ori rm) Perforations. 1 Pe(bracioines 1 Perforations 1' cn $ack4 QAdhesivd Auto Selfaf t6 en la Parte Posterlo ?''Aclh�eif Auto. �calla�it"A L r-ntios 'I Self-Seal:AJlie,§ltle.ori Back:, Bbttoni Bache"r Arlhasiva Auto Sellanta';en Ia Parfe;F'e teriar Apoyo:lnfzr br Xdi Q Auto, Scellanf A.L'Er dos A faui Int ii ur (2) Step Two — Prepare the starter course. For this step, take a 12" x 12" (305mm x11 305mm) ridge cap piece and cut along the line between exposure and headlap (see Figure 2). I Figure 2 . 'tC-ql fAMr ("ni Imin Exposure IR 203 mini Self -Seal Adhesive on Back poker NA 9" (229 mm) ftorri bottom 11':(25 (w'on't e€fge u i J NOA No.: 14-0603.01 Expiration Date: 10/17/17 Approval Date: 12/22/16 Page 7 of 9 I r I (3) Step Three — Place the 4" x 12" (102mm x 305mm) starter cap across the ridge starting at the bottom of the hip or from the end of the ridge opposite the direction of the prevailing wind. Note: For cold weather application or for high wind zones see special application section below. (4) Step Four — Begin laying full ridge cap shingle pieces 12" x 12" (305mm x 305mm) as shown (see Figure 2). Apply with an 8" exposure beginning at the bottom of the hip or from the end of the ridge opposite the direction of the prevailing wind. (5) Step Five — Apply ridge cap using 2 nails per piece 9" back from the exposed end and 1" up from the edge (see Figure 3 for location of nails). Use only zinc coated steel or aluminum, 10-12 gauge, barbed, deformed or smooth shank roofing nails with heads 3/8" (9.5mm) to 7/16" (12mm)'in diameter. Nails should be long enough to penetrate at least 3/4" (19mm) into wood decks or just through plywood decks. Nails must be driven flush with the surface of the shingle. Over driving will damage the shingle. Raised nails will interfere with the wind resistance of the shingles. Figure 3 12" (305mrn) NOA No.: 14-0603.01 Expiration Date: 10/17/17 Approval Date: 12/22/16 Page 8 of 9 T6P L.arninated Piece r 4" 1t2rnm -,. Pieza Superior Lamina& Pius Lamin6e Sup eure -0-1 ° (25m m) 7 (25r iv i �! r Nail 1 Fold Line Nail Clava I Linea de Pliegue Clay Glou Li6ne to Pliage Clou �e 203rnrci NOA No.: 14-0603.01 Expiration Date: 10/17/17 Approval Date: 12/22/16 Page 8 of 9 i Special Application Section: i i For Cold Weather Application • In cold weather, warm GAF Timbertex® Premium Ridge Cap Shingles before bending. • When self-sealing is delayed due to cold weather, apply quarter -sized dabs, of an approved asphalt plastic cement (must conform to ASTM D4586 Type I or Type II) between ridge cap pieces and press firmly to insure good contact between pieces. I� JI For High -Wind Zones, • In high wind areas or for maximum wind resistance, apply a'/4" wide bead'of Henkel Corp. Loctite PLS' Roof & Flashing Sealant to each ridge cap shingle 3/4"-1" from,1the shingle edge, parallel to the ridge (see Figure 4). Note: Excessive application of tab adhesive can cause blistering of ridge cap shingle. ,II Figure 4 12" (305fiiP17.) it Top Lamin6d Pied 4c Pien Superior L;aminadc, 102 Pince Lam mee• Stiperie u re 1` (25mm) i irp'5min)�. .4-1t t1 Nail Fall Lina Nail Claw 1 Line ch Pliegue Clakto Clou Ligrie,I)a Pliage CI©u , , T 203min END OF THIS ACCEPTANCE NOA No.: 14-0603.01 Expiration Date: 10/17/17 Approval Date: 12/22/16 Page 9 of 9