Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BUILDING PERMIT
ALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: Permit Number: q Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772)462-1553 Fax: (772)462-1578 Commercial Residential X PERMIT APPLICATION FOR: Electrical PROPOSED IIMI"PROV',E'M'IENT LbCATib ": Address: 409 SE Verada Ave Port St. Lucie, FL 34983 Legal Description: RIVER PARK-UNIT 4 BLK 32 LOT 45 (MAP 34/28N) (OR 3893-2672) Property Tax ID#: 3419-530-0045-000-0 Lot No.45 Site Plan Name: Block No. 32 Project Name: Setbacks Front Back: Right Side: Left Side: DETAILED ©,ES"CRIPTfC3N"QF W, K: Install electrical wiring for generator Additional work to fl r orme un er t ispermit—c ec a app y: 11HVAC Gas Tank Gas Piping _Shutters ❑Windows/Doors Electric ❑ Plumbing Sprinklers Generator Roof Roof pitch Total Sq. Ft of Construction: Sq. Ft. of First Floor: Cost of Construction: $ Utilities: Sewer []Septic Building Height: OWNE1f LESSEE. % . CON"TRACT"CIR: Name Joseph V Miglino Name: Charles Hoppmann Address: PO Box 845 Company: Bellwether Electric Company City: Indian Hills State:CO Address: 571 NW Mercantile PI #103 Zip Code: 80454 Fax: City: Port St. Lucie State: FL Phone No. Zip Code: 34986 Fax: 772-621-9164 E-Mail: Phone No. 772-621-9494 Fill in fee simple Title Holder on next page ( if different E-Mail: bellwether.electric@gmaii.com from the Owner listed above) State or County License: EC13004122 If value of construction is$2500 or more,a RECORDED Notice of Commencement is required. SUPPLEMENTAL CQNSTRUCTION LIEN jNF'ORMgTIC�N F , DESIGNER/ENGINEER: _ Not Applicable MORTGAGE COMPANY: _ Not Applicable Name: Name: Address: Address: City: State: City: State: Zip: Phone: Zip: Phone: FEE SIMPLE TITLE HOLDER: _ Not Applicable BONDING COMPANY: Not Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans,the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financin onsult with lender or an attorney before commencing work or recording our Notice of Commenc m t. ( &it--- s Signature of Owner/Lessee/Contractor as Agent for Owner Signature of Contractor/License Holder STATE OF FLORIDA STATE OF FLORIDA COUNTY OF COUNTY OF 5 l �u-C t The forgoing instrument was acknowledged before me The forgoing instrument was acknowledged before me this day of 20 _by this_:7- day of Se 2 20 by (Name of person acknowledging) (Name of person ackno edgin (Signature of Notary Public-State of Florida ) (Sig ature of Notary Public-State of Florida ) Personally Known OR Produced Identification Personally Known V/ OR Produced Identification Type of Identification Produced Type of Identification Produced Commission No. (Seal) Commission No. „Q4+Y• DAfSVIeDa�)JURKIEWICZ MY CO09SION#FF998909 EXPIRES June 05,2020 (407)398-0153 FJondaN0tafYb8rV1Ca.CW Revised 07/15/2014 REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE COMPLETE INITIALS Optional Load Calculation 220.80 BELLWETHER NEC 2011 Article 220B- EELECTAIC COMPANY 409 SE Verada Avenue �1 Port Saint Lucie, FL 34983 !� LQAO General Lighting Load 220.82(B)(1) 1986 square feet living area @ 3 VA= 5958 VA Total 5958 VA Minimum Number of Branch Circuits Required 5958 / 120 volts = 49.65 amps 49.65 / 15 amps = 4 circuits 49.65 / 20 amps = 3 circuits Small Appliance Load 220.82(B)(2) 2 Small appliance circuits @ 1500 VA= 3000 VA Total 3000 VA Laundry Load 220.82(B)(2) 1 Laundry Circuit @ 1500 VA= 1500 VA Total 1500 VA Appliances Fastened In Place (Other Than Cooking, Dryers, Heat, and AC)220.82(B)(3&4) Pool Heater @ 42 amps 0 VA 1 1-1/2 HP Pool Pump 2400 VA 1 Pool Lights 300 VA 1 4500 Watt Storage Water Heater 4500 VA 1/3 HP Water Heater Recir. Pump 0 VA 1 1 HP Sewer Grinder Pump 1920 VA Range Hood 120 volt 0 VA 1 Dishwasher 1800 VA 1 1/2 HP Disposal 1176 VA 1 1-1/2 HP Irrigation Pump 2400 VA 1 1 HP Suana Pump 1920 VA 1 1/2 HP GDO 1176 VA 1 Central Vac motor 1176 VA Elevator 2 HP Motor 0 VA Elevator Cab Lights 0 VA Steam Generator Unit 0 VA Electric Car Charger 0 VA 2 Dock Boat Lift 1/2 HP Motor 2352 VA 4 Dock lighting @ 75w 300 VA Landscape Lighting @ 60w 0 VA 1 General-use receptacles @ 180va 180 VA Total 21600 VA Appliance Demand Load @ Name Plate Values 21600 VA Cooking Appliances 220.82(B)(3) Oven at Nameplate 7200 VA Cook Top at Nameplate VA Total 7200 VA Electric Dryers 220.82(B)(3) 1 Dryer(s)At Nameplate= 5000 VA Total 5000 VA Total Load Subject To Demand Factor 44258 Demand Factor 220.82(8) 1st 10000 VA @ 100% 10000 VA Over 10000 VA @ 40% 13703 VA Net Load 23703 VA Fixed Electric Space Heating 220.82(C) 5 KW Heat Strips in A/H With Blower 0 VA 8 KW Heat Strips in A/H With Blower 0 VA 1 10 KW Heat Strips in A/H With Blower 10506 VA Tota 1 10506 VA x 65% 6828.9 VA Heat Pumps 220.82(C) 1.5 Ton Heat Pump 0 VA 2 Ton Heat Pump 0 VA 2.5 Ton Heat Pump 0 VA 3 Ton Heat Pump 0 VA 3.5 Ton Heat Pump .0 VA 4 Ton Heat Pump .0 VA 5 Ton Heat Pump 0 VA Total 0 VA Net Calculated Load 30532 VA For 120/240 Volt 3-Wire Single Phase Service:,,.,,",Amps Optional Load Calculation 220.80 �.., BELLUUETiER Bfa NEC 2011 Article 220 ELECTRIC COMPANY 409 SE Verada Avenue Port Saint Lucie, FL 34983 W General Lighting Load 220.82(8)(1) 1986 square feet living area @ 3 VA= 5958 VA Total 5958 VA Minimum Number of Branch Circuits Required 5958 / 120 volts = 49.65 amps 49.65 / 15 amps = 4 circuits 49.65 /20 amps = 3 circuits Small Appliance Load 220.82(8)(2) 2 Small appliance circuits @ 1500 VA= 3000 VA Total 3000 VA Laundry Load 220.82(8)(2) 1 Laundry Circuit @ 1500 VA= 1500 VA Total 1500 VA Appliances Fastened In Place (Other Than Cooking, Dryers, Heat, and AC) 220.82(8)(3&4) Pool Heater @ 42 amps 0 VA 1-1/2 HP Pool Pump 0 VA 1 Pool Lights 300 VA 4500 Watt Storage Water Heater 0 VA 1/3 HP Water Heater Recir. Pump 0 VA 1 1 HP Sewer Grinder Pump 1920 VA Range Hood 120 volt 0 VA 1 Dishwasher 1.800 VA 1 1/2 HP Disposal 1176 VA 1 1-1/2 HP Irrigation Pump 2400 VA 1 1 HP Suana Pump 1920 VA 1 1/2 HP GDO 1176 VA 1 Central Vac motor 1176 VA Elevator 2 HP Motor 0 VA Elevator Cab Lights 0 VA Steam Generator Unit 0 VA Electric Car Charger 0 VA 2 Dock Boat Lift 1/2 HP Motor 2352 VA 4 Dock lighting @ 75w 300 VA Landscape Lighting @ 60w 0 VA 1 General-use receptacles @ 180va 180 VA Total 14700 VA Appliance Demand Load @ Name Plate Values 14700 VA Cooking Appliances 220.82(B)(3) Oven at Nameplate VA Cook Top at Nameplate VA Total 0 VA Electric Dryers 220.82(B)(3) Dryer(s) At Nameplate --^ .0,VA Total 0 VA Total Load Subject To Demand Factor 25158 Demand Factor 220.82(B) 1st 10000 VA @ 100% 10000 VA Over 10000 VA @ 40% 6063 VA Net Load 16063 VA Fixed Electric Space Heating 220.82(C) 5 KW Heat Strips in A/H With Blower 0 VA 8 KW Heat Strips in A/H With Blower 0 VA 10 KW Heat Strips in A/H With Blower 0 VA Tota I 0 VA x 65% 0 VA Heat Pumps 220.82(C) 1.5 Ton Heat Pump 0 VA 2 Ton Heat Pump OVA 2.5 Ton Heat Pump -0`VA 3 Ton Heat Pump 0`VA 3.5 Ton Heat Pump Q VA 4 Ton Heat Pump 0 VA 5 Ton Heat Pump 0 VA Total 0 VA Net Calculated Load 16063 VA For 120 240 Volt 3-Wire Single Phase Service:..:{:: ;,h rx Amps FPL 120/240 (Existing) 1-Phase 2"GRC (3)4/0 ALUM.XHHW (New) 2" PVC (3)4/0 ALUM. XHHW (Existing) 200-amp 200-amp SE-rated M.B. 0 Automatic Transfer Load Center Switch Meter (Incl. Load MGNT.) (Existing) Socket NEMA-3R (New) 1"PVC (6)#12 THHN CU. Control Wiring (Existing) 16KW GENERAC Generator /2" PVC Pad-mounted (L.P. /Gas) #4 C.0 SOL. BARE 1-1/41,PVC Ufer+Ground Rods+ (3)#4 THHN CU. (New) Water Bond 1 (1)#6 THHN CU. RISER DIAGRAM G round Rod w/#4 Solid Bare CU. }• :t.: � �m'`rid', :. w W _tH -" I a L m E� h r�v 409 SE Verada Ave 0 Em CTMWMft I C An n M Im M&Iff L t H GUMPA Port St Lucie, FL 34983 >:'J...x:.:\ { �. y.n.i,t..Y'•t'{l�'\ l .J, 'K.v.'{ii� <.S {i { y, �..�. ':{>{:.:. '+•: w,'1•.Xv+-...,........,,... .., ...w. .:.v..;3....+..:;:!_x......:......;iv1Rv�,,...„..:..�•.:f.....,v.S-._....kh•{..x.,...,,....vw....kw,o-4.. PO Box 7866 Port St. Lucie, FL 34985•772-621-9494 9 EC13004122