Iry Castle Impact Widows FACTORY DIRECT SINCE 1969 COMPLETE HURRICANE PROTECTION SOLUTIONS 7089 Hemstreet Place West Palm Beach,PL 33413 600,643.6371 Property Information Building Information Owner: JENSEN,GARY Wind Zone: 165 MPH. Address: 1864 WILDCAT COVE DRIVE Exposure Category: D FORT PIERCE,FL 34949 Minimum Building Dimension: 35 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 64 101.5 7 39.0 -42.6 2 Int 64.5 101.5 7 39.0 -42.6 3 End 140.75 96.5 7 36.9 -45.3 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.5th Edition(2014)Florida Building Code. Page 1 of 1 Customer: JENSEN WorkOrder Number: 08012017009 N0301 • Unit No. Wall Opening Opening Shutter Shutter Slat Anchor Pressure Width Height Width Height Length Spacing 1 -42.6 64 101.5 78.875 104 100.75 9"o.c. 12"o.c. 2 -42.6 64.5 101.5 78.5 104 100.75 9"o.c. 12"o.c. 3 -45.3 140.75 96.5 151.75 99 95.75 9"o.c. 12"o.c.