Loading...
HomeMy WebLinkAboutWind Load Calculation SEP 12 &1 PERMITTING � t.Lucie County, FL Property Information Building Information Owner: Foradas Wind Zone: 150 MPH. Address: 15 Lavilla Way Exposure Category: B Ft Pierce;fl 34951 Minimum Building Dimension: 30 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device JDevice_ Max Positive FMax Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 End 74 71 7 26.1 -33.4 2 Int 53 60 7 27.1 -29.5 3 Int 53 60 7 27.1 -29.5 4 End 131 60 7 25.4 -31.9 5 End 105 60 7 25.8 -32.7 6 Int 68 60 7 26.6 -29.0 7 End 74 70 7 26.2 -33.5 8 Int 26 46 7 28.5 -31.0 9 Int 37 71 7 27.4 -29.9 10 Int 26 46 7 28.5 -31.0 Prepared in accordance with:ASCE 7-10,Chapter 30. Rind Loads-Components and Cladding..ith Edition(2014)Florida Building Code. Page 1 of] ------- ----------