Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutProduct Approval � r
BCIS Home Log In User Registration .Hot Topics Submit Surcharge Stats&Facts ; Publications i FBC Staff BCIS Site Map Links Search
0-
,� Product Approval
_ L �- USER:Public User
QQ
Product Annroval Menu>Product or Application Search>Application List>Application Detail
KNOW
N
! t FL# r ' FL13459-R4
Application Type ti Revision
Code Version 2
Application Status Approved
Comments
Archived t..,.'
Product Manufacturer Therma-Tru Corporation
Address/Phone/Email 118 Industrial Drive
Edgerton,OH 43517
(419)298-1740
rickw@rwbldgconsultants.com
Authorized Signature Vivian Wright
rickw@rwbldgconsultants.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email _
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
1! Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E.
the Evaluation Report
Florida License PE-43409
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2018
Validated By Ryan J. King,P.E.
I Validation Checklist-Hardcopy Received
Certificate of Independence FI;13459 R4 COl„.CERTIFICATE of,7NDFPENDENCE.Ddf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1929 1996
ASTM D2843 1999
ASTM D635 2003
ASTM D638 1996
ASTM E1886 2002
ASTM E1996 2002
ASTM E330 2002
ASTM E84 2000
ASTM G26 1995
TAS 201,202,203 1994
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
FL13459 R4 Equiv of STANDARDS.Ddf
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/24/2015
Date Validated OS/01/2015
Date Pending FBC Approval 05/09/2015
Date Approved 06/22/2015
Date Revised 05/15/2016
Summary of Products
FL# Model,Number or Name Description
13459.1 a.Therma-Tru@ Benchmark@ Nominal 6'8"Smooth Surface"or"Wood Grain"Fiberglass
Doors "Impact"Opaque Single Door-(X)Inswing or Outswing
Configuration
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL13454,R4 tI Inst_i3459 i-df
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 13459.1 For Design Pressure Ratings,any FL13459 R4 AE EVAL 13459.1.12df
additional use limitations,installation instructions and FL134S9 R4 AE TT-PLASTICS.odf
product particulars. Created by Independent Third Party:Yes
13459.2 b.Therma-Tru@ Benchmark@ Nominal 6'8"Smooth Surface"or"Wood Grain"Fiberglass
Doors "Impact"Opaque Single Door-(X)Outswing Configuration
Direct to Masonry Installation
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL13459 R4 II Inst 13459.2.Ddf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 13459.2 for Design Pressure Ratings,any FL13459 R4 AE EVAL.13459.2.Ddf
additional use limitations,installation instructions and FL13459 R4 AE TT-PLASTICS.odf
product particulars. Created by Independent Third Party:Yes
13459.3 c.Therma-Tru@ Benchmark@ Nominal 6'8"Smooth Surface"or"Wood Grain"Fiberglass
Doors "Impact"Opaque Single Door with"Impact"Sidelite-(OX or
XO)Inswing or Outswing Configurations
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL13459 R4 I1 Inst 13459.3.Ddf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 13459.3 for Design Pressure Ratings,any FL13459 R4 AE EVAL 13459.3.udf
additional use limitations,installation instructions and FL13459 R4 AE TT-Plastics.l.pdf
product particulars. Created by Independent Third Party:Yes
13459.4d.Therma-Tru@ Benchmark@ Nominal 6'8"Smooth Surface"or"Wood Grain"Fiberglass
Doors "Impact"Opaque Single Door with"Impact"Sidelites-(OXO)
Inswing or Outswing Configurations
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL134S9 R4 II Inst 13459.4.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 13459.4 for Design Pressure Ratings,any FL13459 R4 AE EVAL 13459.4.udf
additional use limitations,installation instructions and FL13459 R4 AE TT-Plastics_1.p f
pr articulars. Created by Independent Third Party:Yes
13459.5 e.Therma-Tru@ Benchmark@ Nominal 6'8"Smooth Surface"or"Wood Grain"Fiberglass
Doors "Impact"Glazed Single Door-(X)Inswing or Outswing
Configuration
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL13459 R4 II Inst 13459.5.Ddf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistt:Yes Created by Independent Third Party:Yes I
Design Pressure. Evaluation Reports
Other:See INST 13459.5 for Design Pressure Ratings,any FL13 159.,_Rq_AE_EVAL_1_h59_S..ptlf
additional use limitations,installation instructions and FL13459 R4 AE TT-Plastics.l.ridF
product particulars. Created by Independent Third Party:Yes
13459.6 f.Therma-Tru@ Benchmark@ Nominal 6'8"Smooth Surface"or"Wood Grain"Fiberglass
Doors "Impact"Glazed Single Door with"Impact"Sidelite-(OX or
XO)Inswing or Outswing Configurations
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL13459 R4 II Inst 13459.6.gdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 13459.6 for Design Pressure Ratings,any FL13459 R4 AE EVAL 13459.6.pdf
additional use limitations,installation instructions and FL13459 R4 AE TT-Plastics.l.pdf
product particulars. Created by Independent Third Party:Yes
13459.7 g.Therma-Tru@ Benchmark@ Nominal 68"Smooth Surface"or"Wood Grain"Fiberglass
Doors "Impact"Glazed Single Door with"Impact"Sidelites-(OXO)
Inswing or Outswing Configurations
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL13459 R4 II Inst 13459.7.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 13459.7 for Design Pressure Ratings,any FL13459 R4 AE EVAL 13459.7.pdf
additional use limitations,installation instructions and FL13459 R4 AE TT-Plastics.1.yd
product particulars. Created by Independent Third Party:Yes
13459.8 h.Therma-Tru@ Benchmark@ Nominal 8'0"Smooth Surface"or"Wood Grain"Fiberglass
Doors "Impact"Opaque Single Door-(X)Inswing or Outswing
Configurations
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL13459 R4 II Inst 13459.8.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 13459.8 for Design Pressure Ratings,any FL13459 R4 AE EVAL.13459.8.0
additional use limitations,installation instructions and FL 1345 R4 AE TT-PI._ASTICaT -
product particulars. Created by Independent Third Party:Yes
13459.9 i.Therma-Tru@ Benchmark@ Doors Nominal 8'0"Smooth Surface"or"Wood Grain"Fiberglass
"Impact"Opaque Single Door with"Impact"Sidelite-(OX or
XO)Inswing or Outswing Configurations
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL13459 R4 II Inst 13459.9.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 13459.9 for Design Pressure Ratings,any F L.1;3459,.._R4
additional use limitations,installation instructions and FL13459 R4 AE TT-Plastics.1.Ix1f
product particulars. Created by Independent Third Party:Yes
13459.10 j.Therma-Tru@ Benchmark@ Nominal 8'0"Smooth Surface"or"Wood Grain"Fiberglass
Doors "Impact"Opaque Single Door with"Impact"Sidelites-(OXO)
Inswing or Outswing Configurations
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes Fl..13 L59R4 11 Inst 1 .IO,pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 13459.10 for Design Pressure Ratings,any FL13t759._.R4 AE EVAL 13459.10.pdf
additional use limitations, installation instructions and FL13459 R4 AE TT-Plastics.i.pdf
product particulars. Created by Independent Third Party:Yes
13459.11 k.Therma-Tru@ Benchmark@ Nominal 8'0"Smooth Surface"or"Wood Grain"Fiberglass
Doors "Impact"Glazed Single Door-(X)Inswing or Outswing
Configurations
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL13459 R4 II Inst 13,159.11.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 13459.11 for Design Pressure Ratings,any FL13459 R4 AE EVAL 13459.1l.p(If
additional use limitations,installation instructions and FL13459 R4 AE TT-Plastics.1.Ddf
product particulars. Created by Independent Third Party:Yes
7uNER'i' AITPtUe
1 0 .iDoors dm
Ben
37.75 MAX. _.. ....._� ice,'•. rbq`. r L N n
gq
1 1 8 INDt16TR1AL DR.. EDGERTON, ❑H 4351 7 f36,W'MiX. ! r*It�� 0 K) z
—PANEL WIDTH I` r}1!`�, m v a•,
�p v i oZo
"Smooth Surface" and "Wood Grain" — a W m a a
FIBERGLASS GLAZED DOOR0_
ItYSW . TSWtIdG s
"IMPACT" a
a
GENERAL NOTES a o z
>r i
3 1. This product has been evaluated and is in compliance with the 5th Edition(2014)Florida Building Code SE
2 (FBC)structural requirements including the"High Velocity Hunicane Zone"(HVHZ). w = r12
M
2. Product anchors shall be as fisted and spaced as shown on details.Anchor embedment to base z w ti
mmaterial shall be beyond wail dressing or stucco, o ® 2 c
3. When used in the"HVHr this product complies with Section 1626 of the Rorido Building Code and does a l o
not require an impact resistant covering. cr j a
og �
4. When used in areas outside of the"HVHZ'requiring wind borne debris protection this product compiles m ><x >
with Section 1609.1.2 of the FBC and does not require an impact resistant covering.This product meets ' ' m
missile level"D'and includes Wind Zone 4 as defined in ASTM El 996 and Section 1609.1.2.2 of the FBC. j f/
5, for 2x stud framing construction,anchoring of these units shall be the some as that shown for 2x buck f
a
masonry construction. N 4
a 6. Site conditions that deviate from the details of this drawing require further engineering anows by aU z
tD� z
licensed engineer or registered architect. f eo L
..........-........
... _ —
o
° 7. Outswing configurations using coastal sill item#31 under active doors meet water infiltration w H
rx
? requirements for"HM".
8. Inswing configurations and outswing configurations using sill items#18,#14,#15,#16,#34% under
$ the door do not meet the water infiltration requirements for the`HVHZ'and shall be Installed only in z
>
non-habitable areas or at habitable locations protected by an overhang or canopy such that the
angle between the edge of canopy or overhang to sill is less than 45 degrees, o m a
M N Oil Q J
TABLE OF CONTENTS_ _
OVERALL DESIGN PRES US RF(PS a z °
SHEEP# DESCRIPTION , SWING FRAME = oare 2/24 09 z
z 1 Typicalelevatons,desl npressures& eneroinotes blMENS10N.: PO$lT1YE DATsrae N.LS.
g Door net details3 DIM BY.4 Vertical cross secfrons INSWING 37.75"x 82.00^ +55.0 - crur LJFKS
5 Buc an trome ancho -2X buc masonry constnrc on6 Frameanc onn -1 ckmasonryconshuchon Drumm :7 Com onents OUTSWING 37.75"x 80.62" +55.0 - FL-13459.5 p
8 B11 of moterais O
�_....._.
SRM1 OF-a-JO
28 DOORSKIN2C A,
tINTERIOR. FOAMCORE Q $
35.81"MAK
DOOR ! y N't .
'PANELWIDTH ` i z 0(D I'll _ R
o�IM
A '�I �•'•' '��\\ J O m l0
44i
EXTERIOR STEEL REINFORCEMENT !! I It n X z'd
f
�GlFOAMCORE oa a.1 H NTAL CROSS SECTION :. 'm d a m
2 e 0z
O DOOR COCKIIARDWARETAII,
� � �1 �;�'�,-,�w•� MANUfACNRER MODEL: o �
SEE DOOR LOCK KNOB: SIGNATURE SERIFS o d
` g HARDWARE TABLE KWIKSET
3 / DEADBOLT: SIGNATURE SERIES o
J y
Q f a
-► 1.11" 4.02'
EXTERIOR INTERIOR �� w cr
o
a DETAILA-A � i"1.53" a �
DOORPANEL
o Smooth S�doce" a a
Woad Grain"
Tol
TOP RAIL HINGE SIRE CKLE $O OM RAILcr
(( Comp. Wood 2C LVOL1Wood ZU Comp. o 0
(TYP.) I'7 N t' to
E EXTERIOR V W o o N
1/7'GLASS BITE
N
CELLULAR I"THK.GLASS
GLAZING
TAPE ,--I/WTEMPEREDGLASS a o w
It -7'DIA.MAX.
513T ANNEALED GLASS w
DOORSKIN
0 0 0 0 0(o o o;-; --0,090"SAFLEX PVB INTERLAYER N i
I "� -1/8"ANNEALED GLASS STEEL REINFORCEMENT o0
DETAIL A-A._.......
0 0
-. DOW 995 �� 2/24/09
aPAN EL REINFORCEMENT 28.86%OPEN OR scute N.T.S.
S (0.023"Thick Steel) MAX SWIGGLEGLAZINGSPACER _..._._._J_....._.._...
AREA SIKA 552 INTERIOR M. JK m
CHK er. LFS 3
zf GLAZING DETA!!
WOOD DOOR COMPONENTS:PINE(SG>=0.42) GTnavnrx
DOOR SKIN 0.070"THL(Fy=6,000 PSI MIN.)
ra-'\ RlCAL CROSS SECTION FL-13459.5
CORE MATERIAL:POLYURETHANE FOAM(PUR.1.91bs.MIN.DENSITY) N
sty 2 or 8 O
O
R:10ients,Ibem Tru PER IANEtMFbrida Ptadua Appm IslFL-134597hennaTm Benchmark HVHZIC-Dranin9slR,13459(2014)R31C11ReRAFL-134$9.5-).dvny 6.1
m_..
w�
z
v z
a
a+
e
4
- _
o�
van ?_— � __._ A w - �,• '.��� v i'
n
03
Z
� 1 r
�=y vy ! AA AN
A W
z
'z
M iA WW WN
A (0
W W
M a 4m
/ 10
fo
x
c
v� No c
H �
0
(� o
I
M
G
iX Z
Io
W N
O
y'0 _
g
{ � A
O
on -
.4
n
a
G
a +
sa
No,43409
i PRCDUCT., Documents Prepared By.�
Lyndon F. Schmidt �.j . .•�Q.. ..
w I R 4 ro FIBERGLASS GLAZED DOOR P.E. No. 43406
W$ y ro 3 1 30 T5 UPDATE TO STH ED. 2014 FSC JK !N!liTlltl%%t
-y Z 2 29 T2 UPDATE TO 2010 FSC JK PART OR ASSEMBLY. @ BUILDING CONSULTANTS, INC.
�oo Io y to p t 3 9 11 REVISE CLASSIC CRAFT DOOR JK HORIZONTAL U(P.O. Sox 230. ValRca. FL.33595
NO DATE BY CROSS SEC77ONS Phone No.: 813.859.9197
REVISIONS FBPE C.A. No. 9813
Q 2009 R.K.BUILDING CONDULT^NTS INC.
P:iCtients\Therms Tru PER,MANFt.`RI lixida Product ApprMIAR-13459 ThennaTm Berxhmark FNHAC-Dfawm9slFt 13459(2014)R3\CuMntWL-13459,5.7.dwg,7.1
--- -1-1/4"NN.
[ rn
:-MB.(TYP.) II
° A C
! q( G c
� al
=m n i_ am t 1
3�mo 0 1
ur
s o n \ ' m A W V (r
00 M aQ� ..
° �n
O \ z 4. .°
C'SWK
p v
n
ww € 1.1/4'MIN.
EMB.
r EMB.(TYP.)
(DI
° Q
fl (p V elA � 7
3=mm'tl
O it ?
"a=�n
N o--A
3-
O�� IM
� • , iM
ea
_
1-IMMN.
EMB.(TYP,)
1 g �
��©crn AN D
5-D
a
q O s~
Mn
-_ff.,,,,
0»'ryi7 Z Qi 1
22
O Rt 7 A
M (((
m y f I j . ap I
`J q �'t1tu(irttt��
o O 4a d v�. SCli
...........
1-1/4"MIN '�' N0.43409 /
EMB.(TYP.)
yth�•1,.
" $ PRODUCT: Document.Pre d By:��.t•�
x Lyndon F. Schmidt �i�C��QQ•�,,•,,•� 0. ..
I N
FIBERGLASS GLAZED DOOR P.E- No. 43409 /��y� «.,��``�
3 t 30 15 UPDATE TO 5TH ER, 2014 FBC JK Q1VAt
11,INC.
,on �" r, r iNi 2 2 29 i2 UPRATE TO 2010 F'6C JK PART OR ASSEMBLY; @ BUILDING CONSULTANTS, INC.
x in p 1 3 9 11 REVISE CLASSIC CRAFT DOOR JK P.O. Box 230,VOir7CO, FL 33595
'1° CAL
w `° NO DATE BY CROSS SECTIONS Phone No.: 613,659.9197
REVISIONS FBPE CA No. 9813
m�2Q09 R.W.SW401NO CO.U.-NI.INC.
...........
\�O��t
ell
Ro
z :o
z
tYP.HERD
i ate.,
d
&JAMBS za
\t a z o
TYP.HERD
IAMBS
O C uiM �dc°
f LL e v m e:a,T
MASONRY _� MASONRY J p �8 �z
OPENING OPENING 0 E v° .
K D & W
v o�j Ua N z
x
FRAME
J13Q
r-
z
r+a z
2X BUCK
M 2XBUCK n Lj LATCH&DEADSOLTDETAIL
0�
o TYP.StLL1 10 a- a �
`fes' L �
10
�`.J �10 p�
€ BUCKANCHORMGHlNGEJAMB FRAMEANCHORING 5TRIKEJAMB
A Masonry 2X buck construction HINGEDETAtL
CONCREMANC14OR NOTES: Inswing
L Concrete onchor locations of the comers maybe adjusted to maintain the min,
edge distance tomortarjoints- _a 9 j z
2.Concrete anchor locations noted as MAX.ON CENTER"must be adjusted to 10 u
a maintain the min.edge distance to mortarjoints,additional concrete onchrrs n ;
may be required to ensure the"MAX,ON CENTER"dimension are not exceeded. • a us z
3 Concrete anchor table.,
MIN.CLEARANCE MIN CLEARANCE J y~s a
ANCHOR ANCHOR M!N- T4;MASONRY TOAQIACtNT', �0 Ma z
SIZE :°:EMBEDMENT
'EDGE ANCHOR
ontE 2124109ttyi
i
TA CONrD 1/4" 1-IX 2" 4" 1 Sete: N.T.S.
T __.._ mvc.6r Jif
2 ELCO m 1/4" 1-IJ4" 1" r
ULTRACON cM sr.. LFS 3
WOOD SCREW INSTALLATION NOTES., atu wria
I.Maintoin a mintmu5/8"edge dutonce,!"end distance,&1"o.c.spacing of HINGE DETAIL
m FL-13459.5
ws a
wood screto prevent the spliffing of woad. Outswingo
o sr�er 5 or 8 �"
s
%N% ..* �1
11
Qu.
Z `Rw. •p M N
O;Eg.
0R0 to om
OZ 10 ZO
i ` UN••
i[ TYP.HEAD& w \ ^ a L o Z m c m
JAMBS �z �1JN a m°� S60u
— �do
MASONRY.T. 28 a c m
— a. ...._._. ....._........ n a
.. �o d z
OPENING M O _ a 9
° 'c'W
Cc
FRAME
27•
ZZ __ .........� O V
C, " z
IX BUCK hLj LATCHLDEADBOLTDETAIL ca ¢p
`J 9 al
TYP.SILLOH— —
o 'O �5�m
10
c � p
~ HINGEJAMB =Aut SMKE JAMS
— o ti
— h N
° HINGE DETAIL v
M CONCRETE ANCHOR NOTES: 9 Inswing w
F I.Concrete anchor locations of the comers may be adjusted to maintain the min.
edge distance to mortar joints. — °z
a 2.Concrete anchor locations noted as°MAX.ON CENTER"must be odjusted to a
u maintoln the min.edge distance to mortarjatnts,odditionot concrete anchors _ z
may be required to ensure the MAX ON CENTER"dimension are not exceeded. 10L
3 Concrete anchor table
r - MtN..CIEARANCE_. MIN-CLEARANCE H ' 1O z n
ANCHOti �.�.. n H
70 MASONRY TOADJACENT 1P
OGE ANC �� L GATE 2124109 c
z 1
a
1/4" t-1/4" 2" 4" sem: N.T.S.
TAPCPC ON __._._...... aysc•BY. JK m
ULTRAC' 1�4" T•T�4" T" 4" clic BY: LFS 3
WOOD SCREW tNSTA"TION NOTES: oa�wu c No.:
1.Molntain a minimum 5/8"edge distance,t"end oWonce.&t"o.c.spacing of HI OG syv nAR a
n g FL-13459.5 a
wood screvr to prevent the sptitNng of wood. IsHmN
a 6 or $ G
z
R:\CreaMilierma Tru PEOMENAFfarida Product ApPm1al5\K-13459 Thenn4TrU Oenchrtwdr HVH2\C-Dmiinga;fL 13459(2014)R3�CUneotlH.-13459.5-7,dwg,10.1 -
IM,
d
TB2 � A
A t
IS 6
i
f �
—{--�-
�
Tp. A$ aI .i N tl=• Cn p(Qy GI S•�, N
N P Rye W aF�y � ��f1y1 W
rail '��� �-�•-C �k=2
� ia' inn rn
p
1
do
--
x
m ate,
La
f* W
0308' a O O `° •
GY27,
$�
ER Documents Fropored Ely:,
Lyndon F. Schmidt �ej�••• � p�% •(.��;���
Iv w Z tv J w9l
LIPOATE TO 5TH ED. 2O]4 FBC JK FlUERGLASS GLAZED DOOR P.E No. 43409 S�� A�,``,'•`�`
!!oe A y p 2 UPDATE TO 2010 F8C JK PART OR ASSEMBLY: (D5 ILDING CONSULTANTS, INC.
1� in R 4i NO GATE RENSE CLASSIC CRAFT DOOR BY COMPONENTS ePy phone Not 0, Vol oo. F 33595
REVISIONS FBPE C.A. No. 9813 V
20-09 R.W.BUILD'Nfa GUNYULiwNr.^..frac.
BILL OF MATERIALS
ITEM DESCRIPTION MATERIAL
A 1X BUCK SG>=0.55 WOOD
B 2X BUCK SG>=0.55 WOOD N7 z°
C MAX.114"SHIM SPACE _ %�':• �. °o M
D 114'X 2-3/4"ELCO OR ITW CONCRETE SCREW _ STEEL 'moi' ''•..,,•,
E MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI CONCREIE '�'��/i��
301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 v a
F 114"X 1-3/-VITW CONCRETE SCREW STEELz 9 z o
H 114"X 3-1/4"ITW CONCRETE SCREW STEEL _ e N o o c a
1 114"X 2-i/4"ITW CONCRETE SCREW STEEL
J 1/4"'X 3-3/4"ITW CONCRETE SCREW STEEL
_ _.._._.._.....................__.___. _- S i
K #8 X 2-1/2'PFH WOOD SCREW STEEL e
L #10 X 2-1/7'PFH WOOD SCREW STEEL o a
7 MEDIUM REACH COMPRESSION WEATHER-STRIP FOAM
8 LONG REACH COMPRESSION WEATHER-STRIP FOAM
9 4"X 4"HINGE.097'THK. STEEL a
10 #10 X 314"PFH WOOD SCREW HINGE TO FRAME STEEL Q
12 #10X 2"PFH WOOD SCREW - STEEL w
13 #9 X 3"PFH WOOD SCREW STEEL -
14
_ SEF ADJUST ALUM./COMP.
_..THRESNOLDOUTSWING " m
15 THRESHOLD OUTSWING-5�3i4"COMPOSITE SILL __ ALUM./COMP.
-16 ITHRESHOLD OUTSWING-5.3/4"COMPOSITE SILL ALUM./COMP.
17 KWIKSETPASSAGE LOCK-SIGNATURE SERIES STEEL o
18 THRESHOLD OUTSWING 5314°THERMAL BREAK SILL ALUM./WOOD
14 HEADER JAMB SG>=0.42 WOOD
20 SIDE JAMB SG>=0.42 WOOD ro
21 KWIKSETDEADBOLT-SIGNATURE SERIES(980) STEEL
27 LATCH STRIKE PLATE STEEL m
30 SECURITY STRIKE PLATE STEEL o
_.__..._.._._...._....---...........
31 COASTAL OUTSWING THRESHOLD ALUM./WOOD $
32 DOOR BOTTOM SWEEP PVC " v
33 INSWING ADJUSTABLE THRESHOLD ALUM./COMP. o
34 OUTSWING THRESHOLD-5-3/4"HARDWOOD SILL ALUM./WOOD c Ln
36 INSWING THRESHOLD-FIXED STANDARD SUBSTRATE_ ALUMJCOMP. ul N
37 OUTSWING THRESHOLD ALUM./COMP.
3B INSWING ADJUSTABLE THRESHOLD-FULLSUBSTRATE ALUM./COMP. Qac
40 DOOR PANEL-SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS - a v
-- »x z
m N
7.
N^Z
CAM 6125108
z
MAM N.T.S.
J
EqLlJK LF:459.5 0: 8 ��