Loading...
HomeMy WebLinkAbout5510 PVC Horizontal Rolling Window ImpactMIAMI·73,3 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 T (786) 315-2590 F (786) 315-2599 www.miamidade.gov/economyNOTICE OF ACCEPTANCE (NOA) PGT Industries, Inc. 1070 Technology Drive North Venice, FL 34275 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements ofthe applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "HIt-5510" PVC Horizontal Rolling Window - L.M.I. APPROVAL DOCUMENT: Drawing No. MD-HR5510-01 titled "Horizontal Roller - LM", sheets 1 through 18 of 18, dated 05/15/15, with revision A dated 05/05/16, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E., bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal ofNOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 15-0903.10 and consists of this page 1 and evidence pages E-1, E-2 and E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. NOA No. 16-0714.17 Expiration Date: September 24,2020 Approval Date: September 01, 2016 Page 1 PGT Industries, Inc. NOTICE OF ACCEPTANCE:EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under previous NOANo.15-0903.10) 2. Drawing No. MD-HR5510-01 titled "Horizontal Roller - LM", sheets 1 through 18 of 18, dated 05/15/15, with revision A dated 05/05/16, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. B. TESTS 1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of a PVC sliding glass door, a PVC fixed window and an aluminum sliding glass door, using: Kodispace 4SG TPS spacer system, Duraseal® spacer system, Super Spacer® NXT™ spacer system and XL Edge™ spacer system at insulated glass, prepared by Fenestration Testing Laboratory, Inc., Test Reports No. FTL-8717, FTL-8968 and FTL-8970, dated 11/16/15, 06/07/16 and 06/02/16 respectively, all signed and sealed by Idalmis Ortega, P.E. 2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94 5) Large Missile Impact Test per FBC, TAS 201-94 6) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of series 5410 and series 5510 PVC horizontal sliding windows, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-8072, dated 02/03/15, signed and sealed by Idalmis Ortega, P.E. (Submitted under previous NOA No.15-0903.10) 3. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94 5) Large Missile Impact Test per FBC, TAS 201-94 6) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of series 5510 PVC horizontal sliding windows, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-8073, dated 02/18/15, signed and sealed by Idalmis Ortega, P.E. (Submitted under previous NOA No.15-0903.10) Manuel Perez,-PS; d- product Control Ex:Oninet·NOA No. 16-0*11:17 Expiration Date: September 24,2020 Approval Date: September 01,2016 E-1 PGT Industries, Inc. D. E. NOTICE OF ACCEPTANCE:EVIDENCE SUBMITTED B. TESTS (CONTINUED) 4. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of series 5510 PVC horizontal sliding windows, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-8074, dated 11/06/14, signed and sealed by Idalmis Ortega, P.E. (Submitted under previous NOANo.15-0903.10) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC-5th Edition (2014), dated 08/28/15, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. (Submitted under previous NOA No.15-0903.10) 2. Glazing complies with ASTM E1300-09 QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER). MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0916.10 issued to Kuraray America, Inc. for their "Butacite® PVB Glass Interlayer" dated 04/25/15, expiring on 12/11/16. 2. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers" dated 06/25/15, expiring on 07/04/18. 3. Notice of Acceptance No. 12-1120.02 issued to Royal Window and Door Profiles, Plant 13 for their "White Rigid PVC Exterior Extrusions for Windows and Doors" dated 02/28/13, expiring on 02/28/18. 4. Notice of Acceptance No. 14-0529.13 issued to Royal Window and Door Profiles, Plant 13 for their "Bronze and Lighter Shades of Cap Coated Rigid PVC Exterior Extrusions for Windows and Doors" dated 04/16/15, expiring on 04/16/20. 5. Notice of Acceptance No. 14-0529.14 issued to Royal Window and Door Profiles, Plant 13 for their "Performance Core Rigid PVC Exterior Extrusions for Windows and Doors" dated 04/16/15, expiring on 04/16/20. E-2 la*u,iUpies,Manuel Pye«' E. 6/ Product Control Txam*er NOA No. 144.17 Expiration Date: September 24,2020 Approval Date: September 01, 2016 PGT Industries, Inc. NOTICE OF ACCEPTANCE:EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of conformance, complying with FBC-5th Edition (2014), dated August 28, 2015, issued by manufacturer, signed and sealed by -Anthony Lynn Miller, P.E. (Submitted under previous NOANo.15-0903.10) 2. Statement letter of no financial interest, dated August 28,2015, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. (Submitted under previous NOA No.15-0903.10) 3. Proposal issued by Product Control, dated 8/27/14 and revised on 9/10/14, signed by Jaime Gascon, P.E. Supervisor, Product Control Section. (Submitted under previous NOA No.15-0903.10) 4. Proposal No. 16-0125 issued by the Product Control Section, dated March 09, 2016, signed by Ishaq Chanda, P.E. E. OTHERS 1. Notice of Acceptance No. 15-0903.10, issued to PGT Industries, Inc. for their Series "HR-5510" PVC Horizontal Rolling Window - L.M.I., approved on 09/24/15 and expiring on 09/24/20. E-3 =tlia Manuel Pewz,f.k. / Product Control xamj,Iler NOA No. 1044.17 Expiration Date: September 24,2020 Approval Date: September 01, 2016 2-5 ANCHORS, SEE CLUSTER DETAILS SHEET 5 8" MAX. A, SEE! SHEET 31 EQUALLY SPACED ANCHORS PER TABLES 17-27 SEE SILL WEEPHOLE DETAILS, SHEET 3 -1 - 1-*- 12-3/4" MAX. O.C. - B, SEE F - SHEET 3 4-444.4-»=-1'% , 10" MAX. 1 ELEVATION FOR TYP. EQUAL LEG FRAME SHOWN AS OX CONFIGURATION X «t A 19"76" MAX. O.C.MAX. BUCK HEIGHT 0 8" MAX. , = BETWEEN -1 SMAX-31--f4" O.C. WEEPHOLES --*a 75" MAX. BUCK WIDTH - | 1-1/4"SEE SHEETS MAX -1 1- 9-16 C, SEE I I .10" MAX.SHEET 41 f I sET SHEETS -- 9-16 [ SEE SILL WEEPHOLE DETAILS, SHEET 4 GENERAL NOTES: SERIES 5510 IMPACT RESISTANT HORIZONTAL ROLLER 0 D, SEE SHEET 4 C 72" MAX. BUCK HEIGHT --*-- 3" MAX.4" O.C. BETWEEN WEEPHOLES --»D 75"MAX. BUCK WIDTH -- ELEVATION FOR TYP. FIN OR J-CHANNEL FRAME SHOWN AS OX CONFIGURATION ANCHORED THROUGH THE NAIL-FIN IMPACT RATING E, SEEI SHEET 3 7 DESIGN PRESSURE RATING VARIES PER REINFORCEMENT LEVEL, SEE SHEETS 6-8 LARGE & SMALL MISSILE IMPACT RESISTANT 2-5 ANCHORS, SEE CLUSTER DETAILS SHEET 5 -=%85 -1 1- 1 -1 1 1894" MAX. O.C._ B, SEE8" MAX. -« F--F · SHEET 3 EQUALLY SPACED ANCHORS PER TABLES 17-27 X O 8" MAX. SEE SILL 1 lilli 1 1 1 11 WEEPHOLE 4" 0.C. BETWEEN - DETAILS,WEEPHOLES SHEET 3 140" MAX. BUCK WIDTH 1) THIS PRODUCT HAS BEEN DESIGNED & TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ). 2) SHUTTERS ARE NOT REQUIRED WHEN USED IN WIND-BORNE DEBRIS REGIONS. FOR INSULATED GLASS INSTALLATIONS ABOVE 30' [N THE HVHZ, THE OUTBOARD LITE (CAP) MUST TEMPERED. 3) FOR MASONRY APPLICATIONS IN MIAMI-DADE COUNTY, USE ONLY MIAMI-DADE COUNTY APPROVED MASONRY ANCHORS. MATERIALS USED FOR ANCHOR EVALUATIONS WERE SOUTHERN PINE, ASTM (90 CONCRETE MASONRY UNITS AND CONCRETE WITH MIN. KSI PER ANCHOR TYPE. 4) ALL WOOD BUCKS LESS THAN 1-1/2" THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1 X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICKOR GREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND SECURED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGN AND INSTALLAT[ON IS THE RESPONSIBILITY OF THE ENGINEER, (EOR) OR ARCHITECT OF RECORD, (AOR). 5) ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. USE ANCHORS OF SUFFICIENT LENGTH TO ACHIEVE REQUIRED MIN. EMBEDMENT. INSTALLATION ANCHORS SHOULD BE SEALED. OVERALL SEALING/FLASHING STRATEGY FOR WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS AND IS BEYOND THE SCOPE OF THESE INSTRUCTIONS. 6) 1/4" MAX. SHIMS ARE REQUIRED AT EACH ANCHOR LOCATION WHERE THE PRODUCT IS NOT FLUSH TO THE SUBSTRATE. USE SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS. 7) DESIGN PRESSURES: A. NEGATIVE DESIGN LOADS BASED ON STRUCTURAL & CYCLE TESTING AND GLASS PER ASTM E1300. B. POSITIVE DESIGN LOADS BASED ON WATER TEST PRESSURE, STRUCTURAL & CYCLE TESTING AND GLASS PER ASTM E1300. 8) THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO RESIST THE WINDLOADS CORRESPONDING TO THE REQUIRED DESIGN PRESSURE. THE 33-1/3% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. THE 1.6 LOAD DURATION FACTOR WAS USED FOR THE EVALUATION OF ANCHORS INTO WOOD. ANCHORS THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE FOR CORROSION RESISTANCE. 9) METAL SUBSTRATE TO MEET MIN. STRENGTH AND THICKNESS REQUIREMENTS PER CURRENT FLORIDA BUILDING CODE AND TO BE REVIEWED BY THE AUTHORITY HAVING JURISDICTION. 10) REFERENCES: TEST REPORTS FTL-8072,8073 & 8074; ELCO ULTRACON NOA; ELCO CRETEFLEX NOA; ELCO AGGRE-GATOR NOA; ROYAL WINDOW AND DOOR PROFILES, LTD WHITE & BRONZE/LIGHTER SHADES OF CAP COATED PVC EXTRUSION NOA'S; NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION, ANSI/AF&PA NDS & ALUMINUM DESIGN MANUAL 11) APPLICABLE EGRESS REQUIREMENTS TO BE REVIEWED BY BUILDING OFFICIAL. USER INSTRUCTIONS: 1) DETERMINE THE SITE SPECIFIC, WINDOW OPENING'S DESIGN PRESSURE REQUIREMENT USING WINDLOAD STANDARD ASCE 7. 2) KNOWING YOUR FRAME TYPE, WINDOW CONFIGURATION (OX, XO, XOX), SIZE, GLAZING OPTION FROM (TABLE 1) AND REINFORCEMENT LEVEL, DETERMINE YOUR WINDOW'S DESIGN PRESSURE REQUIREMENT FOR THE WINDOW OPENING USING TABLES 6-16 (SHEETS 6-8). IT MUST EQUAL OR EXCEED THE DESIGN PRESSURE REQUIREMENT FOR THE WINDOW OPENING OBTAINED IN STEP 1. USE INDEX TABLE 5 ON SHEET 6 TO HELP FIND THE APPROPRIATE TABLE. 3) DETERMINE THE MOST SUITABLE ANCHOR GROUP FROM TABLES 2 AND 3 ON SHEET 2 ACCORDING TO THE INSTALLATION CONDITIONS. 4) DETERMINE THE ANCHOR QUANTITY FROM TABLES 17-27 (SHEETS 9-16), VERIFY THE ANCHOR/SUBSTRATE WILL MEET REQUIREMENTS FOR YOUR OPENING'S CONDITION FROM TABLES 2 OR 3, AND THAT ALL MIN. REQUIREMENTS FROM THIS SHEET SET ARE MET. 5)INSTALL AS PER SHEET 3 FOR FLANGE/EQUAL LEG INSTALLATION OR SHEET 4 FOR INTEGRAL FIN/J-CHANNEL INSTALLATION. USE TABLE 4 ON SHEET 2 TO FIND THE APPROPRIATE DETAILS. NOTE: DESIGN PRESSURE RATING DETERMINATION IS THE SAME PROCESS FOR ALL FRAME TYPES (J-CHANNEL, FLANGE, INTEGRAL FIN OR EQUAL LEG/BOX), SEE FIGURE B ON SHEET 2. X clffi'- A. LYNN:MILLER, P.E. P.E.#58705 1070 TECHNOLOGY DRIVE N. VENICE, FL 34275 P.O. BOX 1529 NOKOMIS, FL 34274 CERT. OF AUTH. #29296 X 1- ELEVATION FOR TYP. FLANGE FRAME Revised By: JR Revised By: SHOWN AS XOX CONFIGURATION Dcte: 05/05/16 Revision: A) ADDED SPACERS TO SHEET 5. E i 63" MAX. BUCK HEIGHT 15.67" MAX. O.C. STANDARDS USED: •2014 FLORIDA BUILDING CODE (FBC), 5TH EDITION •ASTM E1300-09 •ANSI/AF&PA NDS-2012 FOR WOOD CONSTRUCTION •ALUMINUM DESIGN MANUAL, ADM-2010 •AISI-S100-07/52-2010 GENERAL NOTES......................... 1 ELEVATIONS.............................. 1 FRAME, GLASS & ANCHOR OPTIONS 2 INSTALLATION, FLANGE & EQUAL LEG/BOX................. 3 INSTALLATION, INTEGRAL FIN & J-CHANNEL...................... 4 GLAZING DETAILS........................ 5 DESIGN PRESSURES.................. 6-8 ANCHOR QUANTITIES................. 9-16 EXTRUSION PROFILES & BOM....17 ASSEMBLY.....................................18 Date:Revision: Description: GENERAL NOTES & ELEVATION 77tle: HORIZONTAL ROLLER - LM Series/Model: HR-5510 Scale: NTS Sheet: 1 OF 18 __L__. 1.I-B - 3" MAX. PRODUCT REVISED as coinp}yii,8 with tile Florida Expirdon Dale . ... - 40 '20 L- BY 1.#iarni de Prodi,ct C r·W Drown By: J ROSOWSKI Drowing No. MD-HR5510-01 Date: 05/15/15 Rev: A B 7/8" Laminated I. G.. 3/16" T Exterior Cap + 3/8" Air Space + 5/16" Laminated; (2) Lites of 1/8" A Glass with .090" PVB Interlayer Group E 7/8" Laminated I. G.. 1/8" T Exterior Cap + 7/16" Air Space + 5/16" Laminated; (2) lites of 1/8" A Glass with .090" PVB Interlayer 7/8" Laminated I.G.: 1/8" T Exterior Cap + 7/16" Air Space + 5/16" Laminated; (2) Lites of 1/8" H Glass with .090" SG Interlayer A 11 12 14 15 TABLE 1: ALLOWABLE GLASS TYPES Glass Type 5 6 7 8 10 Description (Listed from Exterior to Interior) 7/8" Laminated I.G.: 1/8" A Exterior Cap + 7/16" Air Space + 5/16" Laminated; (2) Lites of 1/8" A Glass with .090" PVB Interlayer 7/8" Laminated I. G.: 3/16" A Exterior Cap + 3/8" Air Space + 5/16" Laminated; (2) Lites of 1/8" A Glass with .090" PVB Interlayer 7/8" Laminated I.G.: 3/16" A Exterior Cap + 3/8" Air Space + 5/16" Laminated; (2) Lites of 1/8" H Glass with .090" SG Interlayer 7/8" Laminated I.G.: 3/16" T Exterior Cap + 3/8" Air Space + 5/16" Laminated; (2) Lites of 1/8" H Glass with .090" SG Interlayer 7/8" Laminated I.G.: 1/8" T Exterior Cap + 5/16" Air Space + 7/16" Laminated; (2) Lites of 3/16" A Glass with .090" S G Interlayer 7/8" Laminated I. G.. 3/16" A Exterior Cap + 1/4" Air Space + 7/16" Laminated; (2) Lites of 3/16" A Glass with .090" S G Interlayer 16 7/8" Laminated I.G.. 3/16" T Exterior Cap + 1/4" Air Space + 7/16" Laminated; (2) Lites of 3/16" A Glass with .090" S G Interlayer SEE SHEET 6, TABLE 5 FOR GLAZING/DESIGN PRESSURE/ANCHORAGE INDEX. TABLE 2: ALLOWABLE ANCHORS THROUGH THE FRAME C D Anchor #10 SMS (steel, 18-8 S.S. or41OS.S.) 3/16" steel Ultracon #12 SMS (steel, 18-8 S.S. or41OS.S.) 1/4" steel Ultracon 1/4" steel Cretellex 1/4" steel Ultracon 1/4" steel Ultracon 1/4" steel Cretellex 1/4" steel Cretellex 1/4" steel Aggre-Gator 1/4" steel Aggre-Gator Substrate P.T. Southern Pine (SG=0.55) Steel, A36* Steel Stud, A653 Gr. 33* Aluminum, 6063-T5* P.T. Southern Pine (SG=0.55) Concrete (min. 2.85 ksi) Ungrouted CMU, (AS™ C-90) P.T. Southern Pine (SG=0.55) Steel, A36* Steel Stud, A653 Gr. 33* Aluminum, 6063-T5* Concrete (min. 2.85 ksi) Ungrouted CMU, (ASTM C-90) Concrete (min- 3.35 ksi) Concrete (min. 2.85 ksi) P.T. Southern Pine (SG=0.55) Concrete (min. 3.35 ksi) Ungrouted CMU, (AS™ C-90) P.T. Southern Pine (SG=0.55) Concrete (min. 3.275 ksi) P,T, Southern Pine (SG=0.55) Grouted CMU, (ASTM C-90) TABLE 3: ALLOWABLE ANCHORS THROUGH THE INTEGRAL FIN Group Anchor 2-1/2' x .131" Common Nail 2-1/2" Ring-shank Rooing Nail #10 Trusshead SMS (steel, 18-8 S.S. or41OS.S.) #12 SMS (steel, 18-8 S.S. or 410 S.S.) Substrate P.T. Southern Pine (SG=0.55) P.T. Southern Pine (SG=0.55) P.T. Southern Pine (SG=0.55) Aluminum, 6063-T5* Steel Stud, Gr. 33* Steel, A36* P.T, Southern Pine (SG=0.55) Aluminum, 6063-T5* Steel Stud, Gr. 33* Steel, A36* Min. Edge Distance 1 , 2-1/2" 9/16" 1" 2-1/2" 1" 2-1/2" 1" 2-1/2" 2-1/2" 7/16" 3/8" 3/8" 3/8" 7/16" 1" 1-1/2" 1" 2" 3/8" 3/8" 3/8" Min. Edge Distance 3/8" 3/8" 1/2" 3/8" 3/8" 3/8" 9/16" 3/8" 3/8" 3/8" Min. Embedment' 1-3/8" 0.050" 0.0451" (18 Ga.) 0.050" 1-3/8" 1-3/8" 1-1/4" la/8" 0.050" 0.0451" (18 Ga.) 0.063" 1-3/4" 1-1/4" 1-3/4" 1-3/4" 1-3/8" 1-3/4" 1-1/4" 1-3/8" 1-3/8" 1-3/8" T Min. Embedment* 2-7/16" 2-7/16" 1-3/8" 0.050" 0.0451" (18 Ga.) 0.050" 1-3/8" 0.063" 0.050" 0.050" GLASS TYPES 5,7,11 & 15MAY NOT BE USED IN THE HVHZ ABOVE 30'. * MIN. OF 3 THREADS BEYOND THE METAL SUBSTRATE. FOR STEEL STUDS, MIN. Fu=45 KSI & MIN. Fy=33 KSI. "UNGROUTED CMU" VALUES MAY BE USED FOR GROUTED CMU APPLICATIONS. ® TABLE 4: INDEX OF INSTALLATION METHODS PER FRAME TYPE Frame Types (see Fig B) J-Channel (#1) Flange (#2) Integral Fin (#3) Box / Equal-Leg (#4) INSTALLATION NOTES, SEE SHEETS 3&4 FOR ILLUSTRATIONS: 1) USE ONLY SUBSTRATE-APPROPRIATE ANCHORS LISTED ON TABLES 2 & 3, THIS SHEET. FOLLOW EMBEDMENT AND EDGE DISTANCE LIMITS. ANY INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF THE WINDOW. 2) MASONRY ANCHORS MAY BE USED INTO WOOD AS PER TABLE 2, THIS SHEET. ALL WOOD BUCKS LESS THAN 1-1/2" THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD. 3) VISIBLE LIGHT WIDTH OR HEIGHT (ALSO REFERRED TO AS DAYLIGHT OPENING) IS MEASURED FROM BEADING TO BEADING. 4) SEE SHEET 18 FOR OPTIONAL EGRESS LOCK DETAILS. * MIN. OF 3 THREADS BEYOND THE METAL SUBSTRATE. FOR STEEL STUDS, MIN. Fu=45 KSI & MIN. Fy=33 KSI. 0*Efic A. LYNN MILLER, P.E. P.E.#58705 Glass Options (see Table 1) 1-4 1-4 1-4 1-4 Installation Conditions Through the integral f n.. Through the frame ofthewindow...... Through the frame ofthewindow...... Through the integral fin...... Through the frame ofthewindow...... Through the frame ofthewindow...... FIGURE B: FRAME TYPES - 8 lE]LFLANGE 1»-=10 J-CHANNEL 32' I 1==1 1 J 1070 TECHNOLOGY DRIVE N. VENICE, FL 34275 P.O. BOX 1529 NOKOMIS, FL 34274 CERT. OF AUTH. #29296 Revised By: Revised By: Date: Date: 8 Substrate Option Detail Sheet into 2XWood Frame/Buckstrip - sheet 4, option 5 into Metal - sheet 4, option 8 into 2XWood Frame/Buckstrip - sheet 4, option 6 into Metal - sheet 4, option 7 into 2XWood Frame/Buckstrip - sheet 3, option 1 ....into Concrete/CMU - sheet 3, option 2 ....through 1X Buckstrip into Concrete/CMU - sheet 3, option 3 ...into Metal - sheet 3, option 4 into 2X Wood Frame/Buckstrip - sheet 4, option 5 into Metal - sheet 4, option 8 into 2XWood Frame/Buckstrip - sheet 4, option 6 into Metal - sheet 4, option 7 into 2XWood Frame/Buckstrip - sheet 3, option 1 ....into Concrete/CMU - sheet 3, option 2 ....through 1X Buckstrip into Concrete/CMU - sheet 3, option 3 ....into Metal - sheet 3, option 4 BOX OR 11--r EQUAL- . » LEG il__0 »43 INTEGRAL 73 FIN 1 i_1__s Revision: Revision: Description: GLASS/ANCHORS/FRAME OPTIONS Title: HORIZONTAL ROLLER - LM Series/Model: HR-5510 Scale: NTS Sheet: 2 OF 18 "A" = ANNEALED "H" = HEAT STRENGTHENED T = TEMPERED "PVB" =.090" BUTACITE® PVB BY KURARAY AMERICA, INC. "SG"090" SENTRYGLAS® INTERLAYER BY KURARAY AMERICA, INC. PRODUCT REVISED as cfampiying wish the Flo*{32 Building CodeAcce»ce No /&0|6E»imtion Date 35#Z44 0 MiaJe Pe#Bt CS,tj- Drown By: J ROSOWSKI Drawing No. MD-HR5510-01 Dote: 05/15/15 Rev: A INSTALLATION DETAILS FOR FLANGE AND EQUAL-LEG FRAMES INSTALLATION OPTION 1 ANCHORED THROUGH FRAME INTO 2X WOOD FRAME OR BUCKSTRIP. SEE NOTE 2, SHEET 2. WEEP NOTCHES 3/4" X 1/4" 1-1M" X 1/4" BUCK HEIGHT EDGE DISTANCE - FLANGE «)-Crus FRAME --<1 SHOWN I6 -bL_UJUT-fU[3 1 0-3--15 11-] L 7 -g-® OPT. VISIBLE LIGHT HEIGHT EXTERIOR 43 (OR(OR( (SEE SHEETS 6-8) TYPICAL FOR ALL SASH EQUALLEG FRAME SHOWN 80 33 INSTALLATION · - - OPTION 2 ANCHORED THROUGH " FRAME DIRECTLY INTO CONCRETE/CMU. TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 2, SHEET 2. : 5 5 VISIBLE LIGHT HEIGHT 81 29 FIXED UTE 5 3' OPERABLE SASH TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 2, SHEET 2. EMBEDMENT ( 4*-fAT--1 r« 29 1 1 rb. Ah /4 3 J \- 34 on-rn-S-l©F-11-7 1- 1 4 .. . . 94 I VERTICAL SECTION B-B 1/4" MAX SHIM #10 OR#12 STEEL SMS (G5), SEE TABLE 2, SHEET 2. DADE APPROVED MULLION, FBC COMPLIANT ALUMINUM/STEEL FRAMING -1 OR STEEL STUD. MAY BE VERTICAL OR HORIZONTAL. SEE SUBSTRATE PROPERTIES, TABLE 2, SHEET 2 29 43 I O» FLANGE FRAME SHOWN 100 114• MAX FSHIM f f EMBEDMENT -| EDGE DISTANCE INSTALLATION OPTION 4 ANCHORED THROUGH FRAME INTO METAL SEE INSTALLATION NOTES SHEET 2 OROR 23 (SEE SHEETS 6-8) TYPICAL FOR ALL "XO" OR "OX" SASH 7-(*)43 - lilli ' -1__1 +1 87 _ L -- 1/4" MAX. SHIM 413 »-«PERABLE13 SASH (37-397 03 /-1» IXED 4UTE A J VISIBLE LIGHT WIDTH \ - 41-3 VISIBLE ' '1 42 EXTERIOR FLANGE LIGHT WIDTH - /»lf!)FRAME OR)OR(2«« 'SHOWN (SEE SHEETS 6-8) TYP CA FOR ALL ·XO" OR"OX" FIXED MEET NG RAIL BUCK WIDTH OPERABLE SASH LIGHT WIDTH VISIBLE 87 85 ()OR>-j (SEE SHEETS 6-8) TYPICAL FOR ALL "XOX" FIXED MEETING RAIL VISIBLE LIGHT FORMULAS (EQUAL-UTE, XO & OX) WIDTH: BUCK WIDTH /2 -4-1/4" HEIGHT: BUCK HEIGHT - 7-1/4" INSTALLATION OPTION 3 ANCHORED THROUGH FRAME AND 1X BUCKSTRIP INTO CONCRETE/CMU. SEE NOTE 2, SHEET 2. EQUAL LEG FRAME SHOWN 22 OR (SEE SHEETS 6-8) TYPICAL FOR ALL "XOX" SASH HORIZONTAL SECTION A-A (OX) OPERABLE (*H \ / SASH .f- F-;421 k...............4/././././././// 1\ 11[[1 'fluR' 1 =IN 4 FIXED A UTE \ \ VISIBLE L GHT WIDTH VISIBLE LIGHT WIDTH P 1 KiL JL 1T-= 1 EXTERIOR G BUCK WIDTH HORIZONTAL SECTION E-E (XOX) INSTALLATION AS PER SECTION A-A ABOVE 1#M_116 j A L+NN 101[LLER, P.E. P.E.#58705 1070 TECHNOLOGY DRIVE N. VENICE, FL 34275 P.O. BOX 1529 NOKOMIS, FL 34274 CERT. OF AUTH. #29296 Revised By: Revised By: Dote: Date: -« F i 12 -31_LIi Revision: Revision: EQUAL-LEG FRAME SHOWN Description: FLANGE & EQUAL-LEG/BOX FRAMES Title: HORIZONTAL ROLLER - LM Series/Model: HR-5510 Scale: NTS Sheet: 3 OF 18 EMBEDMENT EDGE DISTANCE TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 2, SHEET 2. (1) AT MID-SPAN OF INTERLOCK (1) 3-1/2" FROM EACH SASH CORNERAND (1) AT CENTEROF SASH STILES/RAILS PRODUCT REVISED eis complying wilh the Florida Bal<ling Code py Vvi AMIMP Vi€00)PE Ml=*03«0,-0*1*r,1 Drawn By: J ROSOWSKI Date: 05/15/15 Drawing No. MD-HR5510-01 Rev: A INSTALLATION DETAILS FOR FIN AND J-CHANNEL FRAMES INSTALLATION OPTION 5 1 BUCK HEIGHT ANCHORED THROUGH INTEGRAL FIN INTO 2X WOOD FRAME OR BUCK- STRIP. SEE NOTE 2, SHEET 2. J-CHANNEL FRAME SHOWN OPT. 1 CJ VISIBLE LIGHT HEIGHT EXTERIOR OR()OR() (SEE SHEETS 6-8) TYPICALFOR ALL SASH 86 80 81 WEEP 29 NOTCHES 3/4" X 1 /4" -Y 1 -1/4" X 1 /4" 33 FIN FRAME SHOWN TYP. ANCHOR TYPE, EMBEDMENTAND EDGE DISTANCE PER SUBSTRATE, SEE SEE TABLE 3, SHEET 2. »- EMBEDMENT - EDGE -r-- DISTANCE L --, . ' ---1 f --1 --5-UCE}L JU N 1/4" MAX SHIM DISTANCE PER SUBSTRATE, TYP. ANCHOR TYPE, EMBEDMENTAND EDGE SEE TABLE 3, SHEET 2. j FIXED f UTE VISIBLE LIGHT HEIGHT OPERABLE SASH FIN FRAME 1b SHOWN29 15 r--1/of-- 1[-7 <- -I -M EMBEDMENT INSTALLATION OPTION 5 ANCHORED THROUGH INTEGRAL FIN INTO 2X WOOD FRAME OR BUCK- STRIP. SEE NOTE 2, SHEET 2. VERTICAL SECTION D-D INSTALLATION OPTION 7 ANCHORED THROUGH FRAME INTO METAL (INTEGRAL FIN/FLANGE REMOVED) '1 JI 11 , #10 OR #12 STEEL f SMS (G5), SEETABLE 2. SHEET 2, DADE APPROVED MULLION, FBC COMPLIANT ALUMINUM/STEEL FRAMING OR STEEL STUD. MAY BE VERTICAL OR HORIZONTAL. SEE SUBSTRATE PROPERTIES, TABLES 2 & 3, SHEET 2. / FIN AND/OR / FLANGE MAY BE / REMOVED IN-FIELD lili fl) _i SEE INSTALLATION NOTES SHEET 2 ANCHORED THROUGH FRAME INTO 2X WOOD FRAME OR BUCKSTRIP. SEE NOTE 2, SHEET 2. EMBEDMENT - 16 - 1/4' MAX. SHIM (jj>-\.0 (j<>]7 /131)20 OPERABLE (US \ -3--7/37-39 28 , 90 'fs ' {10» [El FIXED 41 ,Ul ,././.I LITE '' 'F-i -- VISIBLE 0»»1 f=tic - ' LIGHT WIDTH-=-a \ j 85 87 0 - VISIBLE 42 1 LIGHT WIDTH - EXTERIOR ()OR()OR<)-- (SEE SHEETS 6-8) TYPICAL FOR ALL "XO" OR"OX' FIXED MEETING RAIL BUCK WIDTH HORIZONTAL SECTION C-C (OX) ® )OR()OR 23 (SEE SHEETS 6-8) TYPICAL FOR ALL "XO" OR "OX" SASH INSTALLATION OPTION 6 FIN FRAME SHOWN EDGE DISTANCE TYP. ANCHOR TYPE, EMBEDMENTAND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 2, SHEET 2. (SCREW SHOWN) INSTALLATION OPTION 8 / (SEE SHEETS 6-8)// // L ANCHORED THROUGH 16 (FLANGE MAY BE REMOVED)TYPICAL FOR -'FIN INTO METAL - ALL 'XOX" OPERABLE (»-\SASH I/ SASH )1_*TZ*-2 15 #10 OR #12 STEEL 9 -= hr--11*= - 1 ' 7- SMS (G5). SEE ,//.////////////7///////////// 11 \11,1 TABLE 2, SHEET 2.ES k C 14VISIBLE / 1 LIGHT WIDTH -4./91 ®- «19) OPERABLE - \\ SASH *-716 Ill (19 c» 4-CRJI' «-3) LIGH WIDTH 1=14» «--»-4== = -1 1 6 - FIXED ., * 'VISIBLE 4 |r-Plr12\LI E /1. - Hc ; 44-7, *OR(»/VISIBLE LIGHT WIDTH 132 (SEE SHEETS 6-8) TYPICAL FOR ALL "XOX" FIXED MEETING RAIL 1 /4" MAX SHIM T EDGE DISTANCE (1) AT MID-SPAN OF INTERLOCK (1) 3-1/2" FROM EACH SASH CORNERAND(1)ATCENTEROF SASH STILES/RAILS VISIBLE LIGHT FORMULAS (EQUAL-LITE, XO & OX) WIDTH: BUCK WIDTH /2 -4-1/4" HEIGHT· BUCK HEIGHT -7-1/4" 42 EXTERIOR 0 BUCK WIDTH HORIZONTAL SECTION F-F (XOX) INSTALLATION AS PER SECTION D-D ABOVE A. LYNN MILLER,'P.E. P.E.#58705 1070 TECHNOLOGY DRIVE N. VENICE, FL 34275 P.O. BOX 1529 NOKOMIS, FL 34274 CERT. OF AUTH. #29296 Revised By: Revised By: Date: Date: Revision: Revision: J-CHANNEL FRAME SHOWN Description: J-CHANNEL & INTEGRAL FIN FRAMES -Title' HORIZONTAL ROLLER - LM Series/Model: HR-5510 Sca/e: NTS Sheet: 4 OF 18 PRODUCT REVISED as centplying witi'* 111*file Buding CodeAccept=ce Ne j -0914.;7 13. 41 3:,cil Date 4,4020 By, Mia§ ede Proddes Comir Drawn By. J ROSOWSKI Drawing No. MD-HR5510-01 Dote: 05/15/15 Rev: A STRUCTURAL POLYISOBUTYLEN WITH DESICCANT EXT. GLASS BUTYL & DESICCANT- FOAM EXT. GLASS STRUCTURAL SILICONE FOAM -1 WITH DESICCANT EXT. GLASS POLYISO- BUTYLENE SEAL ROLL-FORMED STAINLESS STE EXT. GLASS palt # RE SILICONE »\»*<«- 1/4" NOM. r KODISPACE (76) - 4SG TPS INT. GLASS ALUMINUM REINFORCEMENT 5/16" NOM. DURASEAL® - SPACER INT. GLASS HOT-MELT BUTYL -- 3/16" NOM. (S) SUPER- SPACER® NXTTM INT. GLASS DESICCANT FILL AREA 5/16" NOM. SILICONE SEAL 5/16" A/A PVB 7/16" AIR SPACE 1/8" 8 GLASS--- -1 EXTERIOR 5/16" H/H SG 7/16" AIR SPACE 1/8" T GLASS- dl-1 EXTERIOR --1 7/8" NOM. 1-*- . GLASS TYPE 5 -4 7/8"NOM. 1-- GLASS TYPE 10 5@fis EXTERIOR 2* ' 74 0 751 29 mc--J lar 1?5 . .. 1 pi r-=XL EDGE™ (79) - SPACER ®-31 Or-lr--1 INT. GLASS Descriplon 76 Kommerling 4SG TPS Spacer System 77 Quanex Super Spacer n)(T with Hot Melt Butyl 78 Quanex Duraseal Spacer 79 Cardinal X_ Edge Spacer REFERENCE TEST REPORTS: FTL-8717, 8968 & 8970 Ma*rial See this Sheet for Materials TYP. GLAZING DETAIL 5/16" A/A PVB 7/16" AIR SPACE 1/8" I GLASS 11 EXTERIOR 7/8" NOM. » - 718" NOM. - t GLASS TYPE 6 - 7/8" NOM. -- 5/16" H/H SG 3/8" AIR SPACE j 3/16"AGLASS 7 . ] EXTERIOR . GLASS TYPE 11 1/2" NOM.GLASS 7/8" NOM. 1-#BITE TYP. | 7/16" A/A SG 1/4" AIR SPACE 3/16" 8 GLASS- EXTERIOR "A" = ANNEALED "H" = HEAT STRENGTHENED "T" = TEMPERED "PVB" = .090" BUTACITE® PVB BY KURARAY AMERICA, INC. "SG" =.090" SENTRYGLAS® INTERLAYER BY KURARAY AMERICA, INC. FOR LAMINATED GLAZING COMPONENTS, SEE TABLE 1, SHEET 2. \ A V GLASS TYPE 15 6 I i *f//6 A LYNN, MILLER. P.E. P.E.# 58705 . 7/16"AIA SG 1/4" AIR SPACE 5/16" A/A PVB 3/8" AIR SPACE 3/16" A GLASS - -1 EXTERIOR \1 5/16" H/H SG 3/8" AIR SPACE 3/16" I GLASS--j <'Ll EXTERIOR \1 3/16" I GLASS - -11 EXTERIOR ® 1070 TECHNOLOGY DRIVE N. VENICE, FL 34275 P.O. BOX 1529 NOKOMIS; FL 34274 -4 7/8" NOM. 1- --4 7/8" NOM. 4- \ \ --1 Revised By: JR Revised By: Series/Model: HR-5510CERT. OF AUTH. #29296 . GLASS TYPE 7 \ . GLASS TYPE 12 GLASS TYPE 16 Date: 05/05/16 Date: Description: GLAZING DETAILS 4 5/16" A/A PVB 3/8" AIR SPAC[ 3/16" I GLASS 7 -1 EXTERIOR --1 7/8" NOM. 4- . GLASS TYPE 8 -- 7/8· NOM. 1-- 4 7/16" A/A SG I 5/16" AIR SPACE , 1/8" T GLASS» , 3 EXTER[OR tly GLASS TYPE 14 GLASS TYPES 5,7,11 & 15MAY NOT BE USED IN THE HVHZ ABOVE 30'. GLASS TYPES 10-12 & 14-16MAY NOT BE USED WITH J-CHANNEL OR INTEGRAL I FIN FRAMES Revision: A) ADDED SPACERS, MOVED CLSTR. DETAILS. Title: HORIZONTAL ROLLER WINDOW - LM Sheet: 5 OF 18 \ Revision: Scale: NTS PRODUCT REVISED as complying witi.* Floridi Building CodeAcceptace No /6-0714. 17 E*tation Date Ef-i# 0)0 M"tJ,2« Proit, CLAN«--3 Drcwn By: J ROSOWSKI Drawing No. MD-HR5510-01 Dote: 05/15/15 Rev: A TABLE 5: Config. XD or 0X XOX Index to All Design Pressure and Anchor Quantity Tables Max. Width 79' 75" 79' 120" 140" lili lili lili 111 Max. Height 54" 54" 63" 72' 54" 54" 63" 63" 72' 76" 63" 63" Glass Type -« -* 4" MAX. O.C. 4" MAX. O.C.-1 1- 5 6-8 10-12 14 - 16 5-8 5&6 7&8 10-12 14 - 16 8" MAX. O.C. 4"MIN. O.C.-5 lili Reinf. Level 1 2 3 4 1 4 4 3 4 4 4 4 2 3 4 4 Design Pressure Table # 6 7 8 10 6 7 8 11 10 12 12 9 13 14 15 16 5-ANCHOR CLUSTER DETAIL 1111 4-ANCHOR CLUSTER DETAIL 1| 1 .5-ANCHOR CLUSTER DETAIL lili 2-ANCHOR CLUSTER DETAIL 6 7 8 6 6 7 8 8 Sheet# 6 8 8 7 8 8 8 8 Table # 17 18 19 20 17 18 19 21 20 22 22 23 24 25 26 27 Anchor Quantity Sheet # 9 9 10 10 9 9 10 11 10 11 11 12 13 14 15 16 TABLE 6: Glass Types Design Pressure (lbs/ft) 5-8 for X0 or OX Windows Reint Level Rl All Buck Heights up to 54" All Buck Widths up to 75"+50 / -50 SEE TABLE 17 FOR ANCHORAGE SECTION DETAIL FOR WINDOWS WITH LEVEL Rl REINFORCEMENT (REINFORCEMENTS SHOWN IN FIGURES APPLY TO ALL FRAME TYPES & CONFIGURATIONS) JAMB 11__s NOTES: 1) USE THESE TABLES FOR ALL WINDOWS INSTALLED THROUGH THE FRAME OR INTEGRAL FIN. 2) FRAME DIMENSIONS ARE BUCK WIDTH AND BUCK HEIGHT (SHEETS 3-4). SASH SIZE IS AS PER THE FIGURE. 3) FOR SIZES NOT SHOWN, ROUND UP TO THEE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE. 4) "1/4-1/2-1/4" AND "1/3-1/3-1/3" INDICATE THAT THOSE STANDARD SASH CONFIGURATIONS FALL WITHIN THE SASH WIDTH RANGE IN THE ADJACENT COLUMN. "CUSTOM" INDICATES THAT NO STANDARD SASH CONFIGURATIONS FALL WITHIN THE RANGE. EXTERIOR 7 lr S SASH WIDTH rl 3 0,1 21 JU LjOLID 1 Ill HEADER T -fs -71 -an 21 21 SILL r. SASH HEIGHT MEETING RAIL 2 7-4 C EXTER OR 0,>11 JD5 mit j 24 6%-Fiiir A LYNN MILLER, P.E. P.E.# 58705 TABLE 7: Glass Types 5-8 Reinf. Level R2 All Buck Widths uP to 75" SECTION DETAIL Design Pressure (lbs/ft ) for X0 or OX Windows All Buck Heights up to 54" SEE TABLE 18 FOR ANCHORAGE CERT. OF AUTH. #29296 +65 /-70 FOR WINDOWS WITH LEVEL R2 REINFORCEMENT (REINFORCEMENTS SHOWN IN FIGURES APPLY TO ALL FRAME TYPES & CONFIGURATIONS) EXTERIOR <13 ouc_ur_ 1_jc]Ljl.3 C-g--]HEADER g- - L # tu«» SASH HEIGHT EIYf-T_ s ILL Inr--nnr--31¤Fllf, SASH WIDTH b -St=%1 9 In =---1 ' r-0 L 9 4- 6 1FT--B 4__S; 1070 TECHNOLOGY DRIVE N. VENICE, FL 34275 P.O. BOX 1529 NOKOMIS; FL 34274 Revised By: JR Revised By: 21 21 EXTERIOR 0 00 Date: 05/05/16 Date: MEETING RAIL tri 'j L-'i Revision: A) MOVED CLUSTER DETAILS Revision: Description: DESIGN PRESSURE TABLES Title: HORIZONTAL ROLLER - LM Series/Model: HR-5510 Scale: NTS Sheet: 6 OF 18 PRODUCT REVISED as ce[*nplying with the Florida Bdiding Code 6 Drawn By: J ROSOWSKI Drawing No. MD-HR5510-01 Date: 05/15/15 Rev: A 1 2-8 C It' f -12 EXTERIOR 2!6= ========= SASHWIDTH 1.-fL_ljc]L.JI.2 HEADER {=-4}) SASH HEIGHT r X tal[ 0 /4417'R ==ir--3]7 05--1 r 11 *1 , ul 22 JAMB EXTERIOR D 0 SECTION DETAIL FOR WINDOWS WITH LEVEL R3 REINFORCEMENT (REINFORCEMENTS SHOWN IN FIGURES APPLY TO ALL FRAME TYPES & CONFIGURATIONS) 22 , SILL MEET[NG RAIL t] 3 l 25 NOTES: 1) USE THESE TABLES FOR ALL WINDOWS INSTALLED THROUGH THE FRAME OR INTEGRAL FIN. 2) FRAME DIMENSIONS ARE BUCK WIDTH AND BUCK HEIGHT (SEE SHEETS 3-4). SASH SIZE IS AS PER THE FIGURE. 3) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE. 4)"1/4-1/2-1/4" AND "1/3-1/3-1/3" INDICATE THAT THOSE STANDARD SASH CONFIGURATIONS FALL WITHIN THE SASH WIDTH RANGE IN THE ADJACENT COLUMN. "CUSTOM" INDICATES THAT NO STANDARD SASH CONFIGURATIONS FALL WITHIN THE RANGE. TABLE 8. 8 an Glass Types 5-8 Reint Level R3 All Buck Widths uP to 75" TABLE 9: Glass Types 5-8 Reinf Level R3 35-114" 38" 45-1/8" 47-3/4" 52-lj8" 60" 75" 96" 120' Design Pressure (lbs/ft2) for X0 or OX Windows All Buck Heights up to 63" +50/-50 SEE TABLE 19 FOR ANCHORAGE Sash Configuration %-34-% %-%-% %-%-% %-%-% %-%-% %-%-% Custom %-%-% %-%-34 Custom %-%-% %-%-34 Custom %-%-% %-%-% Custom 14-%-% Custom %-%-% Sash Width Range (in) 11.391-11.391 12.308 - 12-308 11391 - 13.397 13.398 - 14-683 11.391 -12-297 12298 -15.558 11.391 -12016 12.017 - 13 397 13.398 - 17.016 11391 - 13.397 13.398 - 15.360 15.361 - 19.641 11.391 -13.397 13.398 - 19.110 19.111 -24641 18.360 - 19 397 19398 - 24.360 24.361 - 30.360 -30.360 * +50/-50 FOR GLASS TYPES 6-8 WINDOW WIDTH - 59.28** MIN. SASH S[ZE = 2 A. LYNN MILLER, P.E. P.E.#58705 +50.0 +50.0 +500 50.0 -500 -50.0 -50.0 -500 500 50.0 50.0 -50.0 -500 -50-0 -5QO -50.0 -50.0 50.0 50.0 +50.0 +50.0 +50.0 +50.0 +500 +500 +50.0 +50.0 +50.0 +50.0 +50.0 +50.0 +50.0 +50-0 +500 +50.0 Design Pressure (lbs/ftl for XOX Windows 1070 TECHNOLOGY DRIVE N. VENICE. FL 34275 P.O. BOX 1529 NOKOMIS; FL 34274 VA 48" -500 -50.0 50.0 CERT. OF AUTH. #29296 +50.0 +50.0 +50.0 +50.0 +50.0 +500 +50.0 +50.0 +500 +50.0 +50.0 +50.0 +50.0 +50.0 +50.0 +50.0 indow Buck Heigil 54" +50.0 -50.0 +50.0 -50.0 +50.0 500 -500 -500 50-0 -50.0 ·50.0 -50.0 -50.0 -50.0 -50.0 -50.0 -50.0 50.0 50.0 -500 -50.0 50.0 +50.0 +50.0 +49.1' +49.1* 63" -50.0 -50.0 Revised By:Date: Dote: +50- 0 +50.0 +50.0 +50.0 +50.0 +50.0 +50.0 +50.0 +500 +50.0 +50.0 +50.0 +50.0 +50.0 +50.0 491' -49.1 ' Revised By: Revision: Revision: Description: DESIGN PRESSURE TABLES Series/Model: HR-5510 -50.0 50.0 -500 50.0 50.0 -50-0 500 50.0 50.0 -50_0 50.0 50.0 50.0 50.0 -50.0 SEE TABLE 23 FOR ANCHORAGE Title: HORIZONTAL ROLLER - LM Scale: NTS Sheet: 7 OF 18 PRODUCT REVISED as compiying wiel tbe Ft@rida Mi(Arl Dade Predict Ce**v 1 Drawn By: J ROSOWSKI Drawing No. MD-HR5510-01 Date: 05/15/15 Rev: A 8 TABLE 10: Glass Types 6-8 Reint Level R4 All Buck Widths up to 75' TABLE 15: 3: 0 P Glass Types 10-12 Reinf. Level R4 60" 75' 96" 120" 140" Design Pressure (lbs/ft) for X0 or OX Windows All Buck Heights up to 72 +50 / -50 SEE TABLE 20 FOR ANCHORAGE Sash Configuration Custom %-%-% 1%-%-1/L Custom %-%2 -1% %-%-% Custom %-%-1% Custom %-35-% %3-%-% Custom Sash Width Range On) 11.391 - 13.397 13.398 - 15.360 15.361 - 19.641 11.391 - 13.397 13.398 -19.110 19.111 -24.641 17.641 - 19.397 19.398 - 24.360 24.361 -31.641 29.641 - 32.515 32.516 - 39.641 ** - 39.641 * +65/-110 FOR GLASS TYPES 11 & 12 TABLE 16: Glass Types 14-16 Reint Le\el R4 60" 75" 96" 120" 140" Sash Coniguration Custom %-%-% %-%-1% Custom 14-1%-% %3-%-% Custom %-16.% Custom 1%.34-14 %-%-% Custom Sash Width Range (in) 11.391 -13.397 13.398 - 15.360 15.361 - 19.641 11.391 - 13.397 13.398-19.110 19.111 -24.641 17.641 - 19.397 19.398 - 24.360 24.361 -31.641 29.641 - 32.515 32.516 -39.641 ** - 39.641 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65,0 -110.0 -110.0 -110.0 -110.0 -110.0 -110.0 -110.0 -110.0 -110.0 -110.0 -110.0 -110.0 -110.0 -110.0 -110.0 -110 0 -110.0 -110.0 -110.0 -110.0 -110.0 -110.0 TABLE 11: 22£ Glass Types 5-8 Reinf Le,el R4 25-1/2" 28" 36" 42" 48" 60" 79 48" Design Pressure (lbs/ff) for X0 or OX Windows +650 | -70.0 +65.0 -70.0 +65.0| -70.0 +6501 -70.0 +65.0 | -70.0 +65.0 | -700 +65.0 | -70.0 * +65/-70 FOR GLASS TYPES 6-8 SEE TABLE 21 FOR ANCHORAGE Design Pressure (lbs/ft) for XOX Windows 43" -110.0 V/in(:low B 54 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 U ck Heig it -110.0 -110.0 -110.0 -110.0 -110.0 -110.0 -110.0 -110.0 -110.0 -110.0 -110.0 -110.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0* +65.0* +65 0 +65.0* +65.0 +65.0* 63" 'indow Buck Heig 54" +65.0 -70.0 +65.0 -700 +65-0 -70.0 +65-0 -700 +65.0 -70.0 +65-0 -70.0 +65-0 -70.0 -110.0 -110.0 -110.0 -110.0 -110.0 -110.0 -104.6* -109.5* -110.0 -104.6* -110.0 -104.6* it 63" +65.0 -700 +650 : -70.0 +65.0 | -700 +65.0 | -700 +65.0 1 -70.0 +65.0 | -70.0 +643* | -64.7 SEE TABLE 26 FOR ANCHORAGE WINDOW WIDTH - 60.72 " MIN. SASH SIZE = 2 Design Pressure (lbs/ftl for XOX Windows 48" -110.0 Window Buck Heig it +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 54" -110.0 -110.0 -110.0 -110.0 -110.0 -110.0 -110.0 -110.0 -110.0 -109.8 -105.0 -105.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 63" -110.0 -110.0 -110.0 -109.3 402.0 -102.9 SEE TABLE 27 FOR ANCHORAGE -80.0 -97.4 -92.0 -88.4 -84.3 -80.8 EXTERIOR 41 2£ TABLE 12: Glass Types 10-12 & 14-16 Reinf Level R4 25-1/2" 28" 36" 42" 48" 60" 75" Design Pressure (lbs/ft) for X0 or OX Windows 54" +65.0 | -110.0 +65.0 -110.0 +65.0 |-110.0 +65.0 1 -110.0 +65.0 |-110.0 +65.01-110.0 +65.0 i -110.0 Window Buck Heig it 63' +65.0 1-110.0 +65.0 |-110.0 +65.0 | -110.0 +65.0|-110.0 +650 -1100 +65.0 -1100 +65.01-103.5 +65.0 +65.0 +65.0 +65.0 +650 +65.0 +65.0 76" 110.0 110.0 -110.0 -110.0 110.0 -939 40.0 SEE TABLE 22 FOR ANCHORAGE guL_JUL__JLJOL-JU f»=j[--411 HEADER SASH -- HEIGHT f - 181 11,)=f':Jul=-0 1 0 16119 , SILL Inr-nr-tr--3]Flnflf. 1 1 SASH WIDTH 1LJ'--1-isru £1 -4 / L=j}18\--titROR 23di L; 0 9 NOTES: 1) USE THESE TABLES FOR ALL WINDOWS INSTALLED THROUGH THE FRAME OR INTEGRAL FIN AS ALLOWED BY GLASS TYPE. 2) FRAME DIMENSIONS ARE BUCK WIDTH AND BUCK HEIGHT (SEE SHEETS 3-4). SASH SIZE IS AS PER THE FIGURE. 3) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE. 4)"1/4-1/2-1/4" AND "1/3-1/3-1/3" INDICATE THAT THOSE STANDARD SASH CONFIGURATIONS FALL WITHIN THE SASH WIDTH RANGE IN THE ADJACENT COLUMN. "CUSTOM" INDICATES THAT NO STANDARD SASH CONFIGURATIONS FALL WITHIN THE RANGE. 0/.7 -Clpf,116 A. LYNN MILLER, P.E. P.E.#58705 £ 1 8 TABLE 13: Glass Types 5&6 Reinf Level R4 60" 75' 96" 120" TABLE 14: Glass Types 7&8 Reint 1-evel R4 60" 75' 95' 120" Sash Coriguration Custom %-%-% %-%-% Custom %-1%-1% %-%-% Custom %-%-% Custom %-%-1% ** 11.391 -13.397 13.398 - 15.360 15.361 - 19.641 11.391 -13.397 13.398 -19.110 19.111 -24.641 18.360 - 19.397 19.398 - 24.360 24.361 - 30.360 ** - 30.360 MIN. SASH SIZE = Sash Configuration Custom %-%-% %-%-% Custom 1%-1%-1% K-%-% Custom 1%-%-1% Custom Sash Width Range (in) %-%-% Sash Width Range (in) 11.391 - 13.397 13.398 - 15.360 15.361 -19.&41 11.391 - 13.397 13.398-19.110 19.111 -24.641 18.360 - 19.397 19 398 -24.360 24.361 - 30.360 ** - 30.360 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 36" -70.0 -70.0 -70.0 -70.0 -70.0 -70.0 -70.0 -70.0 -70.0 Design Pressure (lbs/ft?) for XOX Windows -70.0 -70.0 -70.0 -70.0 -70.0 -70.0 -70.0 -70.0 -70.0 -70.0 WINDOW WIDTH - 2 * +65/-70 FOR GLASS TYPE 8 WINDOW WIDTH - 59.28 " MIN. SASH SIZE = 2 SECTION DETAIL MEE ING RAIL FOR WINDOWS WITH LEVEL R4 REINFORCEMENT (REINFORCEMENTS SHOWN IN FIGURES APPLY TO ALL FRAME TYPES & CONFIGURATIONS)r] ,} j 1070 TECHNOLOGY DRIVE N. VENICE, FL 34275 P.O. BOX 1529 NOKOMIS; FL 34274 CERT. OF AUTH. #29296 Revised By: Revised By: Date: Date: +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +59.9 +62.1 +65.0 +59.9 59.28 Window B Jck Height 48"54 -70.0 -70.0 -70.0 -69.6 -70.0 -70.0 -70.0 -59.9 -59.9 ·62.1 +65.0 +65.0 +65.0 +633 +65.0 +65.0 +55.5 +58.0 +65.0 +55.5 -70.0 -70.0 -70.0 -70.0 -70.0 -70.0 -70.0 -70.0 -70.0 -70.0 -70.0 -70.0 -633 -66.5 -70.0 -55.5 -58.0 473 -55.5 +49.1 63' -65.3 -70.0 -70.0 -53.2 -56.2 -66.0 -49.1 -50.3 -57.0 49.1 SEE TABLE 24 FOR ANCHORAGE Design Pressure (lbs/ff) for XOX Windows 36" -70.0 +650 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 GLASS TYPES 10-12 & 14-16MAY NOT BE USED WITH J-CHANNEL OR INTEGRAL I FIN FRAMES Revision: Revision: Description: DESIGN PRESSURE TABLES Title: HORIZONTAL ROLLER - LM Series/Model: HR-5510 Scoje: NTS Sheet: 8 OF 18 Window B 43" -70.0 -70.0 -70.0 -70.0 -70.0 -70.0 -70.0 -70.0 -70.0 -70.0 ick Height 54" +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 SEE TABL -70.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0 +65.0* +65.0 +65.0 +65.0 +53.2 +56.2 +65.0 +49.1 +50.3 +57.0 -57.2' -68.8* -700 -57.2' 25 FOR ANCHORAGE PRODUCT REVISEDj as celitplying with 11* PioilidE Build,ng CodeA,nek£(e Ne. 14>-07 /4. 17 Ihimtion Di,elI: *2001//MY Drawing No. MD-HR5510-01 +65.0* +65.0* +65.0 63' Drcwn By: J ROSOWSKI -70.0 -70.0 -70.0 -70.0 -70.0 -70.0 Date: 05/15/15 Rev: A Z CO % -2 TABLE 17: cn % E Glass Types 5-8 Reint Level R1 TABLE 18: 8 . 8 CO i k 25-1/2" 28" 36" 42" 48" 60" 75" 25-1/2" 28" 36" 42" 48" 60" 75" Glass Types 5-8 Reinf. Level R2 25-1/2" 25-1/2" 28" 36" 42" 48" 60" 75" 28" 36" 42" 48" 60" 75" Sash Width On ) 12.147 13.397 17.397 20.397 23.397 29.397 36.897 12.147 13.397 17.397 20.397 23.397 29.397 36.897 Sash Width On) 12.147 13.397 17.397 20.397 23.397 29.397 36.897 12.147 13.397 17.397 20.397 23.397 29.397 36.897 30" Height Head & Sill 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 30" Height Head & Sill 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 E -J n E 10 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 36" Height Head & Sill Anchor Quantities for XO or OX Windows 48" Height Head & Sill Anchor Group A 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 3 3 3 3 3 3 3 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 Anchor Group B 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 36" Height Head & Sill n E CO 3 3 3 3 3 3 3 n E (03 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 3 3 3 3 3 3 3 n E -J 3 3 3 3 3 3 3 54" Height Head & Sill 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 E (C -J 3 3 3 3 3 3 3 3 3 3 3 3 3 3 30" Height Head -2 & Sill 4 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 36" Height Head & Sill 1% 48" Height Head -@ & Sill 1% Anchor Group C 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 3 3 3 3 3 3 3 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 Anchor Group D 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 Anchor Quantities for XO or OX Windows 48" Height Head & Sill Anchor Group A Not Allowed Anchor Group B 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 3 3 3 3 3 3 3 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 E to 3 3 3 3 3 3 3 54" Height Head & Sill 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 n E 30" Height Head · & SiU 4 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 3 1+C2+1 3 1+C2+1 3 1+C2+1 3 1+C2+1 3 1+C2+1 3 2+C2+2 3 2+C2+2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 54" Height Head 2 & Sill 4 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 1+(2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 3 3 3 3 3 3 3 SEE TABLE 6 FOR DESIGN PRESSURE 36" Height Head -2 & Sill 2 48" Height Head & Sill Anchor Group C 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 3 3 3 3 3 3 3 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 Anchor Group D 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 E SEE TABLE 7 FOR DESIGN PRESSURE 3 3 3 3 3 3 3 3 3 3 3 3 3 3 54" Height Head · & Sill 1% 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Max. Anchor O.C. Spacing for "Integral- Fin" Installation Anchor Group E 3.8" Anchor Group F 4" GUIDE TO USING ANCHOR QUANTITY TABLES FOR OX WINDOWS (XO SIMILAR): 2+C3+2 L SEE ELEVATION, SHEET 1 ANCHOR QUANTITY 'S- PER JAMB 3 HEAD AND SILL ANCHOR QUANTITY: (2) ANCHORS AT THE FIXED SECTION + A CLUSTER OF (3) ANCHORS CENTERED AT THE MEETING RAIL + (2) ANCHORS AT THE SASH TOTAL OF 7 ANCHORS AT THE HEAD AND 7 ANCHORS AT THE SILL. - SEE ELEVATION, SHEET 1 1-+- SEE ELEVATION, SHEET 1 - SEE CLUSTER DETAILS, SHEET 6 SEE ELEVATION, SHEET 1 MEETING RAIL REPEAT ANCHOR PATTERN AT SILL FOR XOX WINDOWS: 1+C3+2+C3+1 =RnAnn,,1„112 11 1 .s| SEE ELEVATION, SHEET 1 SEE ELEVATION,j- ]1 4 I_Ill 4 0--- 3.A tSHEET 1 IIi ,- - MEETING RAIL-- \SEE CLUSTER L DETAILS, SHEET 5 REPEAT ANCHOR PATTERN AT SILL Max. Anchor O.C. Spacing for "Integral- Fin" Installation 4 ANCHOR QUANTITY PERJAMB HEAD AND SILL ANCHOR QUANTITY: (1) ANCHOR AT THE SASH + A CLUSTER OF (3) ANCHORS CENTERED AT THE MEETING RAIL + (2) ANCHORS AT THE FIXED SECTION + A CLUSTER OF (3) ANCHORS CENTERED AT THE MEETING RAIL + (1) ANCHOR AT THE SASH TOTAL OF 10 ANCHORS AT THE HEAD AND 10 ANCHORS AT THE SILL. SEE ELEVATION, SHEET 1 1-- SEE ELEVATION, SHEET 1 11 14- SEE ELEVATION, SHEET 1 Anchor Group F 4" NOTES: 1) FRAME DIMENSIONS ARE BUCK WIDTH AND BUCK HEIGHT (SEE SHEETS 3-4). SASH SIZE IS AS PER THE FIGURES ON SHEETS 6-8. 2) FOR SIZES NOT SHOWN, ROUND UP To THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE. 1 -1 PRODUCT REVISED as com*yiwig with the Figsids, Building Code.AIMptmce No 16«0«Zf.*51 Eiration Date S.Br. 4 6 3*An....F,r,l. By "11(*1*,4*kKA Mus:Igna#*#C=*47 li .rj LU > >E CD N 9: 0U I LJ- 00 WE 2> N 10 LL 46 0= 00 0 03 0-Z 0 0 r- 0 CO 1 LL 0 0 0 a#DO 00 LU -J Cn <C 1- Z a Of 0 I 0 Z <C 311!1 48 UMDJO '0580 6-18116 A LYNN MILLER, P.E. P.E.#58705 (0 0 8 05 -J CE LU 0 Z 0 N 0 I AaM r- 0 0 L0 LO I ON DMO 00 IL 0 C) le,VS CO Il Z FDOS 0 L0 In Ck I sa.uas -C= 5 m 0 45 m E TABLE 20: Glass Types 5-8 Reinf. Lewl R4 25-1/2" 28" 36" 42" 48" 60" 75" 25-1/2" 28" 36" 42" 48" 60" 75" TABLE 19 1 4£ g In l Sash Width (in) Glass Types 5-8 12.147 13.397 17.397 20.397 23.397 29.397 36.897 Reinf. Level R3 12.147 13.397 17.397 20.397 23.397 29.397 36.897 25-1/2" 28" 36" 42" 48" 60" 75" 25-1/2" 28" 36" 42" 48" 60" 75" Sash Width Ci n ) 12.147 13.397 17.397 20.397 23.397 29.397 36.897 30" Height Head & Sill 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 12.147 13.397 17.397 20.397 23.397 29.397 36.897 -n E 2 2 2 2 2 2 2 2 2 2 2 2 2 2 30" Height Head & Sill 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 36" Height Head & Sill 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 n E 1% E to 2 2 2 2 2 2 2 2 2 2 2 2 2 2 36" Height Head & sill 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 48" Height Head & Sill 3 3 3 3 3 3 3 48" Height - Head -@ Ig & Sill 1 Anchor Group A 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 Anchor Group B 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 54" Height Head & Sill Anchor Group A 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C3+2 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C3+2 E 4 1+C2+1 1+C2+1 1+C2+1 4 4 4 4 4 4 4 4 4 4 4 4 4 4 3 3 3 3 3 3 3 1+C2+1 1+C3+1 2+C3+2 2+C3+2 Anchor Group B 1+C2+1 2+C2+2 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C3+1 2+C3+2 2+C3+2 E .f: 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 5 5 5 5 5 5 5 n E CO 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Anchor Quantities for XO or OX Windows 54" Height Head & siu 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 63" Height Head & Sill 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C3+2 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 E 4 4 4 4 4 4 4 4 4 4 4 4 4 4 30" Height Head -@ & Sill 1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 2 2 2 2 2 2 2 36" Height Head & Sill 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 Anchor Quantities for XO or OX Windows 63" Height Head & Sill 1+C2+1 1+C2+1 1+C2+1 1+C3+1 1+C3+1 2+C3+2 2+C4+2 1+C2+1 1+C2+1 1+C2+1 1+C3+1 1+C3+1 2+C3+2 2+04+2 n E 72" Height 30" Head 2 & sill 4 1+C2+1 1+C2+1 1+C3+1 1+C3+1 1+C3+1 2+C4+2 2+C4+2 1+C2+1 1+C2+1 1+C3+1 1+C3+1 1+C3+1 2+C4+2 2+C4+2 Height Head 2 & sill 1 5 1+C2+1 5 1+C2+1 5 1+C2+1 5 1+C2+1 5 1+C2+1 5 2+C2+2 5 2+C2+2 5 1+C2+1 5 1+C2+1 5 1+C2+1 5 1+C2+1 5 1+C2+1 5 2+C2+2 5 2+C2+2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 36" Height Head & Sill 1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 48" Height ·@ Head ·@ 3% & Sill jg Anchor Group C 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 Anchor Grou 3 1+C2+1 3 1+C2+1 3 1+C2+1 3 1+C2+1 3 1+C2+1 3 2+C2+2 3 2+C2+2 48" Height Head & Sill f Anchor Group C 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C3+2 Anch 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C3+2 0 4 4 4 4 4 4 4 r 4 4 4 4 4 4 4 G P 4 4 4 4 4 4 4 4 4 4 4 4 4 4 D 54" Height Head & Sill 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 E CC 4 4 4 4 4 4 4 63" Height Head & Sill 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 SEE TABLE 8 FOR DESIGN PRESSURE 54" Height Head 2 & Sill .9 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C3+1 2+C3+2 2+C3+2 roup D 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C3+1 2+C3+2 2+C3+2 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 63" Height Head - & Sill f 1+C2+1 1+C2+1 1+C2+1 1+C3+1 1+C3+1 2+C3+2 2+C4+2 1+C2+1 1+C2+1 1+C2+1 1+C3+1 1+C3+1 2+C3+2 2+C4+2 5 5 5 5 5 5 5 5 5 5 5 5 5 5 4 4 4 4 4 4 4 72" Height Head -@ & Sill 4 1+C2+1 1+C2+1 1+C3+1 1+C3+1 1+C3+1 2+CA+2 2+CA+2 1+C2+1 1+C2+1 1+C3+1 1+C3+1 1+C3+1 2+C4+2 2+C4+2 5 5 5 5 5 5 5 5 5 5 5 5 5 5 SEE TABLE 10 FOR DESIGN PRESSURE n E CO 4 4 4 4 4 4 4 Max. Anchor O.C. Spacing for "Integral- Fin" Installation Anchor Group E 3.5' Anchor Group F 4" Max. Anchor O.C. Spacing for "Integral- Fin" Installation Anchor Group E 3.2" Anchor Group F 4" NOTES: 1) FRAME DIMENSIONS ARE BUCK WIDTH AND BUCK HEIGHT (SEE SHEETS 3-4). SASH SIZE IS AS PER THE FIGURES ON SHEETS 6-8. 2) FOR SIZES NOT SHOWN, ROUND UPTO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE. 3) SEE SHEET 9 FOR A GUIDE TO USING THESE TABLES. CS LU > 'r . 10 r A ON 02 I W- 00 0-% 1 s pli E30 Inf : /12 / 1 U- W 0 CN AS LO LL xe 06 m O a_ Z El Mia„. f)'ide Pmdrxt Centre g (D 1 CD PRODUCT REVISED as ceR}plying witii th< Flofitta Building CodeAceeplailce No 16* 01 *4«. 17 Expiratioe D.te -*20 1.0 0 400 3 111 2 (0 0 00 0 XEd UMDJO 050 A#Fir A. LYNN MILLER, P.E P.E.# 58705 (0 11.1 CD 1- 1- Z < D C CE 0 I 0 Z <C -1 <C Z 0 N OC 0 I LU _1 -1 0 <C AGH 9 0 r·- L0 L0 OC I ON SMO 00 LL 0 0 /@@VS 60 Z 3)33T 0 LO L0 02 I Sal.IGS -1£ 8 m 0 .2 TABLE 22: g CO 8 -2 TABLE 21: Glass Types 5-8 Glass Types 10-12 & 14-16 Reinf. Level R4 25-1/2" 25-1/2" 28" 36" 42" 48" 60" 75" 28" 36" 42" 48" 60" 75" .C '8 8 01 Reinf. Level R4 25-1/2" 28" 36" 42" 48" 60" 75" 25-1/2" 28" 36" 42" 48" 60' 75" Sash Width (in) 12.147 13.397 17.397 20.397 23.397 29.397 36.897 12.147 13.397 17.397 20.397 23.397 29.397 36.897 Sash Width (in) 12.147 13.397 17.397 20.397 23.397 29.397 36.897 12.147 13.397 17.397 20.397 23.397 29.397 36.897 30" Height Head & Sill 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 30" Height n E 63 2+C2+2 Head & Sill 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 2 2 2 2 2 2 2 2+C2+2 E (0 -J 36" Height Head & Sill 1+C2+1 Head & Sill 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 2 2 2 2 2 2 2 n E 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 36" Height 3 3 3 3 3 3 3 E 3 3 3 3 3 3 3 4 4 4 4 4 4 4 48" Height Head & Sill Anchor Group A Not Allowed Anchor Group B 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 48" Height Head & Sill n E (0 n E -J 4 4 4 4 4 4 4 n E CO Anchor Quantities for XO or OX Windows 54" Height Head & Sill 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 54" Height Head & Sill Anchor Group A Not Allowed Anchor Group B 1+C2+1 1+C2+1 1+C2+1 1+C3+1 1+C3+1 2+C3+2 2+C3+2 1+C2+1 1+C2+1 1+C3+1 1+C3+1 1+C3+1 2+C3+2 2+C4+2 4 4 4 4 4 4 4 n E 4 4 4 4 4 4 4 n E (0 Head & Sill 5 5 5 5 5 5 5 63" Height 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C3+2 2+C3+2 E (C 4 4 4 4 4 4 4 E -J 30" Height Head 2 & sill 4 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 36" Height Head 2 & Sill 4 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 48" Height Head -@ & Sill 4 Anchor Group C 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 Anchor Grou 3 1+C2+1 3 1+C2+1 3 1+C2+1 3 1+C2+1 3 1+C2+1 3 2+C2+2 3 2+C2+2 Anchor Quantities for XO or OX Windows 63" Height Head & Sill 1+C2+1 1+C3+1 1+C3+1 1+C3+1 1+CA+1 2+C4+2 2+C4+2 76" Height Head & Sill 1+C3+1 1+C3+1 1+C4+1 1+C4+1 1+C4+1 2+C4+2 2+C4+2 30" Height Head & Sill 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 5 1+C2+1 5 1+C2+1 5 1+C2+1 5 1+C2+1 5 1+C2+1 5 2+C2+2 5 2+C2+2 n E 'S= 36" Height Head & Sill 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 3 3 3 3 3 3 3 -0 E 3 3 3 3 3 3 3 3 3 3 3 3 3 3 P 4 4 4 4 4 4 4 4 4 4 4 4 4 4 D 54" Height Head 2 & S 111 4 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 4 4 4 4 4 4 4 2+C2+2 2+C2+2 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 63" Height Head & Sill 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C3+2 1+C2+1 1+C2+1 1+C2+1 1+C2+1 1+C2+1 2+C2+2 2+C2+2 n E CO 4 4 4 4 4 4 4 SEE TABLE 11 FOR DESIGN PRESSURE 48" Height Head E & Sill 4 54" Height Head ·E & Sill 4 Anchor Group C 1+C2+1 1+C2+1 1+C2+1 1+C3+1 1+C3+1 2+C3+2 2+C3+2 4 4 4 4 4 4 4 1+C2+1 1+C2+1 1+C3+1 1+C3+1 1+C3+1 2+C3+2 2+C4+2 Anchor Group D 1+C2+1 1+C2+1 1+C2+1 1+C3+1 1+C3+1 2+C3+2 2+C3+2 1+C2+1 1+C2+1 1+C3+1 1+C3+1 1+C3+1 2+C3+2 2+CA+2 4 4 4 4 4 4 4 63" Height Head & Sill 1+C2+1 1+C3+1 1+C3+1 1+C3+1 1+C4+1 2+C4+2 2+C4+2 1+C2+1 1+C3+1 1+C3+1 1+C3+1 1+CA+1 2+(4+2 2+C4+2 4 4 4 4 4 4 4 E CO 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Max. Anchor O.C. Spacing for "Integral- Fin" Installation 76" Height Head -@ & Sill 1 1+C3+1 1+C3+1 1+C4+1 1+C4+1 1+C4+1 2+C4+2 2+C4+2 1+C3+1 1+C3+1 1+C4+1 1+C4+1 1+C4+1 2+C4+2 2+C4+2 5 5 5 5 5 5 5 5 5 5 5 5 5 5 SEE TABLE 12 FOR DESIGN PRESSURE Anchor Group F 4" GLASS TYPES 10-12 & 14-16 MAYNOT BE USED WITH J-CHANNEL I OR INTEGRAL FIN FRAMES NOTES: 1) FRAME DIMENSIONS ARE BUCK WIDTH AND BUCK HEIGHT (SEE SHEETS 3-4). SASH SIZE IS AS PER THE FIGURES ON SHEETS 6-8. 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE. 3) SEE SHEET 9 FOR A GUIDE TO USING THESE TABLES. CS CV . OZ LU > ac . LO r 1% CD N 02 00 oW PRODUCT REVISED as ce,apjying wilh the Fio'*ds Buikfing Code Acceptence No 16·07,4.17 Expiration Date t>eN 28 *20\hkA10fl Mi»fulC:*«Prodect C.9,»/ 01 AS UD LL r- - X9 06 a 0 0- Z 1 @ E LL 0 12 LU 0 8 CD 1 CD all<1 XB UMDJO -Gil,1114 . 10 0 910(} A. LYNN;MILLER, P.E. P.E.# 58705 00 ILI CO <C 1- Z D 0 CK 0 I 0 Z <C 0980 2 CO 0 8 05 -1 LLI 0 Z 0 N 0 I r- 1£'DVS CO Il Z FDOS 0 L0 LO 02 I saues ON DMO 00 IL 0 ABM 9 0 LCD L0 I .C 5 CO 0 E CD 0 E TABLE 23· Glass Types 5-8 Reint Le\el R3 35-1/4" 38" 45-1/8" 47-3/4" 52-1/8" 60" 75" 96" 120" 35-1/4" 38" 45-1/8" 47-3/4" 52-1/8" 60" 75" 96" 120" Sash Conguration %3-1%-% *-%-% %-%-% %-%-% %-%-% %3-%-1% Custom %-%-% %-%-% Custom %-%-% %-*3-% Custom %-%-% %-%-% Custom %-%-% Custom %-%-% 7-%-% %3-*3-% %-%-% >1-%-1% %-%-% %-%-1% Custom %-%-% %-%-% Custom 1%-%-% %-%-% Custom %-%-% %-%-% Custom %-%-% Custom %-34-% Max. Anchor O.C. Spacing for "Integral- Fin" Installation Sash Width Range (in) 11.391 -11.391 12.308 - 12.308 11.391 -13.397 13.398 - 14 683 11.391 - 12.297 12.298 - 15.558 11.391 - 12.016 12.017 - 13.397 13.398 - 17016 11.391 -13.397 13.398 - 15.360 15.361 - 19.641 11.391 - 13.397 13.398 - 19.110 19.111 -24.641 18.360 - 19.397 19.398 - 24.360 24.361 - 30.360 ** - 30.360 11.391 -11.391 12.308 - 12.308 11.391 -13.397 13.398 - 14.683 11.391 - 12297 12.298 - 15.558 11.391 - 12.016 12.017 - 13.397 13.398 - 17.016 11.391 -13.397 13.398 - 15.360 15.361 - 19.641 11.391 - 13.397 13.398 - 19.110 19.111 -24.641 18.360 - 19.397 19.398 - 24.360 24.361 - 30.360 ** - 30.360 Anchor Group E 2.9" 24" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 Anchor Group F 4" £1 E CIO 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 30" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+(2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+02+0+(2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+(2+1+(2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+(2+1+(2+1 1+(2+1+(2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 n E (0 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 36" Height Head & Sill 48" Height Head & Sill Anchor Group A 1+C2+0+C2+1 1+C2+0+C2+1 1+02+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 3 3 3 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 Anchor Group B 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 in E (g 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 WINDOW WIDTH - 59.28 " MIN. SASH SIZE = 2 E (0 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 54" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+CQ+1 1+(2+1+C2+1 1+(2+1+(2+1 1+CQ+0+(2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 E (0 Anchor Quantities for XOX Windows 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 63" Height Head & SIN 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C3+3+C3+1 1+C3+3+C3+1 1+C3+2+C3+1 1+C3+3+C3+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 n E 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 24" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+(2+0+(2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+(2+3+(2+1 1+C2+3+C2+1 1+02+2+C2+1 1+(2+3+(2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+(2+0+(2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 E ro 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 30" Height Head & Sill 1+C2+0+(2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 n E (0 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 36" Height Head & Sill 48" Height Head & Sill Anchor Group C 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+€2+1+C2+1 1+C2+0+C2+1 1+(2+1+(2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 Anchor Group D 1+C2+0+C2+1 1+02+0+02+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+02+2+02+1 1+C2+3+C2+1 n E {0 -J 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+02+0+02+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 -0 E m 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 54" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 E (g 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 63" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 SEE TABLE 9 FOR DESIGN PRESSURE NOTES. 1) FRAME DIMENSIONS ARE BUCK WIDTH AND BUCK HEIGHT (SEE SHEETS 3-4). SASH SIZE IS AS PER THE FIGURES ON SHEETS 6-8. 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE. 3) SEE SHEET 9 FOR A GUIDE TO USING THESE TABLES. 4) "1/4-1/2-1/4" AND"1/3-1/3-1/3" INDICATE THAT THOSE STANDARD SASH CONFIGURATIONS FALL WITHIN THE SASH WIDTH RANGE IN THE ADJACENT COLUMN. "CUSTOM" IND[CATES THAT NO STANDARD SASH CONFIGURATIONS FALL WITHIN THE RANGE. 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 E (0 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 DS W > 01 >r CD N 02 I LJ- 00 R> PRODUCT REVISED as rempiying wiah The Fk:fida Bddma Code Acceptant© No 16071*. 17 Mip.m,/Eade P,ada©t Cofitro,/ V 1 @ 1 0,1 W LL A - 05 00 0 IL Z 0 0 (0 1 9- C> 8 0 L0 0 84[)0 811!1 LU CO <C Z D a Cls 0 I 0 Z <C Al UADJ(] Osa(] 6111 lit - A LYNN MILLER, P.E. P.E.#58705 2 CO 0 8 li -1 Z 0 N 0 I -1 OC LU -1 -1 0 ON OMO 00 r- LL 0 (\1 ia@WS 1- Z .=35- 0 L0 Ok I Sauas ASH 9 0 10 LO CE I .£= 3 8 R TABLE 24: l Glass Types 5&6 Reinf. Level R4 35-1/4" 38" 45-1/8" 47-3/4" 52-1/8" 60" 75' 96" 120" 35-1/4" 38" 45-1/8" 47-3/4" 52-1/8" 60" 75" 96" 120" Sash Configuration %-%-% %-%-% *4-%-% %-%-% %-%2-1% A-%-% Custom 1%-%-1% %-%-% Custom %-%-% %-%-% Custom %-%-% %-%-1% Custom %-%-% Custom %-%-% %-1%-M %-%-% %-%-% %-%-M %4-%-%4 %-%-% Custom 1%-*-1% %-%-% Custom 1%-%-1% %-%-% Custom 1%-%-1% %-%-% Custom %-%-% Custom 1%-%-% Max. Anchor O.C. Spacing for "Integral- Fin" Installation Sash Width Range On) 11.391 -11.391 12.308 - 12.308 11.391 13.398 11.391 12.298 11.391 12.017 13.398 11.391 13.398 15.361 11.391 13.398 19.111 18.360 19.398 24.361 ** - 13.397 -14.683 -12.297 -15.558 - 12.016 - 13.397 - 17.016 - 13.397 - 15.360 - 19.641 - 13.397 -19.110 - 24.641 -19.397| -24.360 - 30.360 | - 30.360 11.391 -11.391 12.308 - 12.308 11.391 - 13.397 13.398 - 14.683 11.391 - 12.297 12.298 - 15.558 11.391 - 12.016 12.017 - 13.397 13.398 - 17.016 11.391 - 13.397 13.398 - 15.360 15.361 - 19.641 11.391 - 13.397 13.398 - 19.110 19.111 -24.641 18.360 - 19.397 19.398 - 24.360 24.361 - 30 360 ** - 30.360 Anchor Group F 4" 24' Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 E (0 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 30" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 E (0 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 36" Height Head & Sill 0 E {0 48" Height n Head & Sill @ Anchor Group A Not Allowed Anchor Group B 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 WINDOW WIDTH - 59.28 ** MIN. SASH SIZE = - 2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1+C2+0+C2+1 4 1+C2+0+C2+1 4 1+C2+0+C2+1 4 1+C2+0+C2+1 4 1+C2+1+C2+14 1+C2+0+C2+1 4 1+C2+1+C2+1 4 1+C2+1+C2+14 1+C2+0+C2+1 4 1+C2+1+C2+1 4 1+C2+1+C2+1 4 1+C2+0+C2+1 4 1+C2+3+C2+1 4 1+C2+2+C2+1 4 1+C2+1+C2+1 4 1+C2+3+C2+1 4 1+C2+3+C2+1 4 1+C2+2+C2+1 4 1+C2+3+C2+1 4 54" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 n E (0 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Anchor Quantities for XOX Windows 63" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C3+0+C3+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 n E (C 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 24" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+02+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 E tu 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 30" Height Head & SIN 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 n E (0 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 36" Height Head & Sill 0 E (0 48" Height Head & Sill Anchor Group C 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 Anchor Group D 1+C2+0+C2+1 3 1+C2+0+C2+1 1+C2+0+C2+13 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 E (0 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 54" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+02+0+02+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 E m 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 63" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 NOTES:SEE TABLE 13 FOR DESIGN PRESSURE 1) FRAME DIMENSIONS ARE BUCK WIDTH AND BUCK HEIGHT (SEE SHEETS 3-4). SASH SIZE IS AS PER THE FIGURES ON SHEETS 6-8. 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE. 3) SEE SHEET 9 FOR A GUIDE TO USING THESE TABLES. 4) "1/4-1/2-1/4" AND "1/3-1/3-1/3" INDICATE THAT THOSE STANDARD SASH CONFIGURATIONS FALL WITHIN THE SASH WIDTH RANGE IN THE ADJACENT COLUMN. "CUSTOM" INDICATES THAT NO STANDARD SASH CONFIGURATIONS FALL WITHIN THE RANGE. 4 n E (J 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 CM 1 111 > . 10 (D N 02 I ui 00 0< 14»:0%,te Pre<6*4©ot l.f 41 8 LL 0 0 0 0 CO 1 C) PRODUCT REVISED as complying wich the Plollh Building Code AcceD{stee No 16-olt* 17 tration Date 2090 N- CN gs 0 LL Xe 0= 00 O 05 a. Z Lf) E 0 OlD(] 311!1 f 'l(f/.1-6 A. LYNN MILLER, P.E. P.E.#58705 CO LU -J CD <C 1- Il 1- Z <C D a OC 0 I 0 Z 2 (/) B 0 8 0/ -J A8 UMD30 -J CE LU _1 0 1- Z 0 N 0 I 'OSGO <C AGN 9 0 10 If) I ON SMC CO LL 0 M 1aa4S 00 Z a/DOS 0 L0 LO I Salues IZ R #C 8 00 j TABLE 25: *3 C Glas s Types 7&8 Reinf. Level R4 35-1/4" 38" 45-1/8" 47-3/4" 52-1/8" 60" 75" 96" 120" 35-1/4" 38" 45-1/8" 47-3/4" 52-1/8" 60' 75" 96" 120" Sash Configuration 3-%-% %-%-% 34-14-34 7-%-% %-55-% %-34-% Custom %4-%-% 16-%-% Custom 34-%-% %-%-% Custom %4-%2-%4 7-34-% Custom 14-36-% Custom %4-34-34 %-%-% %-%-% %-%-% M-%-% %4-%-1% K-%-% Custom %-%-% M-%-% Custom %4-%-% 34-%-% Custom %-%-% M-%-% Custom %4-%-% Custom %-K-% Max. Anchor O.C. Spacing for "Integral- Fin" Installation Sash Width Range On) 11.391 - 11.391 12.308-12.308 11.391-13.397 13.398 - 14.683 11.391 -12.297 12.298 - 15.558 11.391 -12.016 12017 -13.397 13.398 - 17.016 11.391 -13.397 13.398 -15.360 15.361 -19.641 11.391-13.397 13.398-19.110 19.111 -24.641 18360- 19.397 19.398-24.360 24.361 - 30.360 ** - 30.360 11391-11.391 12.308 - 12.308 11.391-13.397 13398 - 14.683 11391 -12.297 12298-15.558 11.391 -12.016 12.017 - 13.397 13.398 - 17.016 11391 - 13397 13.398 - 15.360 15.361 -19.641 11.391-13.397 13.398-19110 19111-24.641 18360- 19.397 19.398 - 24.360 24.361 - 30.360 ** - 30.360 Anchor Group F 3.7" 24" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+(2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+02+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 /1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 30" Height Head & Sill 1+C2+0+C2+1 1+02+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+02+1+(2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+02+2+C2+1 1+C2+3+C2+1 ¤ E 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 36" Height Head & Sill n E 48' Height Head & SIN Anchor Group A Not Allowed Anchor Group B 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 WINDOW WIDTH - 59.28 ** MIN. SASH SIZE = 2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 E -SE 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 54'Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 Anchor Quantities for XOX Windows n 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 63" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C3+0+C3+1 1+C2+3+02+1 1+C3+2+C3+1 1+C3+1+C3+1 1+C3+3+C3+1 1+C3+3+C3+1 1+C3+2+C3+1 1+C3+3+C3+1 4 4 4 4 4 4 4 4 4 4 4 4 n E IE 4 4 4 4 4 4 4 24" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+02+1+02+1 1+C2+1+C2+1 1+C2+0+C2+1 1+02+1+C2+1 1+C2+1+C2+1 1+02+0+02+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 n E IE 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 30"Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+(2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 -0 E 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2· 2 2 2 2 36" Height Head & Sill n E 48" Height Head & Sill Anchor Group C 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+(2+1+02+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+(2+1+02+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 Anch 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 0 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 r G 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 roup D 1+C2+0+C2+1 1+C2+0+C2+1 1+02+0+(2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 E IE 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 54" Height Head & SIN 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 1+C2+0+C2+1 1+02+0+(2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 f1 E .SR 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 63" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+(32+1+C2+1 1+C2+0+C2+1 1+C 2+1+C2+1 1+C2+1+C2+1 1+02+0+(2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C3+3+C3+1 1+C3+2+C3+1 1+C3+3+C3+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+1+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+3+C2+1 SEE TABLE 14 FOR DESIGN PRESSURE NOTES: 1) FRAME DIMENSIONS ARE BUCK WIDTH AND BUCK HEIGHT (SEE SHEETS 3-4). SASH SIZE IS AS PER THE FIGURES ON SHEETS 6-8. 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE. 3) SEE SHEET 9 FOR A GUIDE TO USING THESE TABLES. 4) "1/4-1/2-1/4" AND "1/3-1/3-1/3" INDICATE THAT THOSE STANDARD SASH CONFIGURATIONS FALL WITHIN THE SASH WIDTH RANGE IN THE ADJACENT COLUMN. "CUSTOM" INDICATES THAT NO STANDARD SASH CONFIGURATIONS FALL WITHIN THE RANGE. n E 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 LU 2 C) 0 01 02 Z Ll- I UU- 00 WZ 1 PRODUCT REVISED as complying with the ittoride Buildisia CodeAcceptig©e Ne 160-*7141 i 7- Expiration Dat®351;117M 0% <*.1.& Ar 3.1 Misni hde Product Contsol«* 01 a) CV) Nj lo U. Xe 06 m 0 0- Z LL 0 LLI 0 0 0 (D 1 0) +DO L8 UAD)(] C<«lf@i- 10 E 0 81#11 A. LYNN 1('ACLER, P.E. P.E.# 58705 00 LU 00 1- Z <C D a 0 I 0 Z <C 0%0 CO 0 8 -J LU 0 CK --1 1- Z 0 N CK 0 I <C )38 9 0 A- L0 L0 02 I ON DMO 00 LL 0 r- 1@9.05 CO 1- Z == 0 L0 02 I saues C TABLE 26. m Glass Types 10 - 12 Reint Level R4 35-1/4" 38" 45-1/8" 47-3/4" 52-1/8" 60" 75" 96" 120" 140" 35-1/4" 38" 45-1/8" 47-3/4" 52-1/8" 60" 75" 96" 120" 140" Sash Confguration %-%-% i-%-% %-%-% %3-M-%3 %-%-% *-h-% Custom y-%-% Custom 1%-34-% A-%-% Custom %-%-% y-y-y Custom %-%-% %-%-% 14-16-1% %-%-% Custom %3-%-% %-%-% %-%-% %-%-% %-1%-1% %-%-% Custom 1%-*-1% %-%-% Custom 1%-M-% 34-%-% Custom %-%-1% %-y-% Custom %-%-% %3-%3-1% %4-*-% %-%-% Custom GLASS TYPES 10-12 & 14-16MAY NOT BE USED WITH J-CHANNEL OR INTEGRAL I FIN FRAMES Sash Width Range (in) 11.391 -11.391 12.308 - 12.308 11.391 -13.397 13.398 - 14.683 11.391 -12.297 12.298 - 15.558 11.391 - 12.016 12.017 - 13.397 13.398 - 17.016 11.391 -13.397 13.398 - 15.360 15.361 - 19.641 11.391 - 13.397 13.398 - 19.110 19.111 -24.641 17.641 - 19.397 19.398 - 24.360 24.361 - 31.641 29.641 - 32.515 32.516 - 39.641 ** - 39.641 11.391 -11.391 12.308 - 12.308 11.391 -13.397 13.398 - 14.683 11.391 - 12.297 12.298 - 15.558 11.391 - 12.016 12.017 - 13.397 13.398 - 17.016 11.391 - 13.397 13.398 - 15.360 15.361 - 19.641 11.391 - 13.397 13.398 -19.110 19.111 -24.641 17.641 - 19.397 19.398 - 24.360 24.361 - 31.641 29.641 -32.515 32.516 - 39.641 ** - 39.641 24" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+02+0+(2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+2+C2+1 1+C2+2+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+CE+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 2+C2+2+C2+2 2+C2+3+C2+2 2+C2+3+C2+2 2+C2+3+C2+2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 30" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+2+C2+1 1+C2+2+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+02+3+C2+1 1+C2+0+C2+1 1+02+3+C2+1 1+C2+3+C2+1 2+C2+3+C2+2 2+C2+3+C2+2 2+C2+3+C2+2 2+C2+3+C2+2 { 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 WINDOW WIDTH - 60.72** MIN. SASH SIZE = 2 36" Height Head & Sill 48" Height n Head & Sill Anchor Group A Not Allowed Anchor Group B 1+C2+0+C2+1 3 1+C2+0+C2+1 1+C2+0+C2+1 3 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+2+C2+1 1+C2+2+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C3+0+C3+1 1+C2+4+C2+1 1+C2+4+C2+1 2+C2+3+C2+2 2+C2+4+C2+2 2+C2+3+C2+2 2+C2+4+C2+2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C2+2+C2+1 1+C2+2+C2+1 1+C3+0+03+1 1+C2+3+C2+1 1+C3+3+C3+1 1+C3+0+C3+1 1+C3+4+C3+1 1+03+4+(3+1 2+C3+3+C3+2 2+C3+4+C3+2 2+C3+4+C3+2 2+C3+4+C3+2 n E 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 54" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C3+0+C3+1 1+C2+0+C2+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+(3+1 1+C3+0+C3+1 1+C3+2+C3+1 1+C3+2+C3+1 1+C3+0+C3+1 1+C3+3+C3+1 1+C3+3+C3+1 1+C4+0+C4+1 1+C3+4+C3+1 1+C3+4+C3+1 2+C3+3+C3+2 2+C3+4+C3+2 2+C4+4+C4+2 2+C4+4+C4+2 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Anchor Quantities for XOX Windows 63" Height @ Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+2+C3+1 1+C3+2+C3+1 1+CA+0+C4+1 1+C3+3+C3+1 1+CA+3+C4+1 1+04+0+C4+1 1+C4+4+C4+1 1+CA+4+C4+1 2+CA+3+C4+2 2+C4+4+C4+2 2+C5+4+C5+2 2+C5+4+C5+2 li 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 24" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+2+C2+1 1+02+2+02+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 2+C2+3+C2+2 2+C2+2+C2+2 2+C2+3+C2+2 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+02+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+2+C2+1 1+C2+2+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+2+C2+1 2+C2+3+C2+2 2+C2+2+02+2 2+(2+3+(2+2 il 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 30" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+2+C2+1 1+C2+2+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+02+3+C2+1 2+C2+2+C2+2 2+C2+3+C2+2 2+C2+3+C2+2 2+C2+3+C2+2 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+2+C2+1 1+C2+2+C2+1 1+C2+0+C2+1 1+02+33+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 2+C2+3+C2+2 2+C2+3+C2+2 2+C2+3+C2+2 n E 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 36" Height Head & Sill 48" Height Head & Sill Anchor Group C 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+2+C2+1 1+C2+2+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C3+0+C3+1 1+C2+3+C2+1 1+C2+3+C2+1 2+C2+2+C2+2 2+C2+3+C2+2 2+C2+3+C2+2 2+C2+3+C2+2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C2+0+C2+1 1+C2+2+C2+1 1+C2+2+02+1 1+C3+0+C3+1 1+C2+3+C2+1 1+C3+3+C3+1 1+C3+0+C3+1 1+C3+4+C3+1 1+C3+4+C3+1 2+C3+3+C3+2 2+C3+4+C3+2 2+C3+3+C3+2 2+C3+4+C3+2 Anchor Group D 1+C2+0+C2+1 3 1+C2+0+C2+1 1+C2+0+C2+1 3 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+03+0+(3+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 2+C2+3+C2+2 2+C2+3+C2+2 2+C2+3+C2+2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C2+0+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C3+0+C3+1 1+C2+3+C2+1 1+C3+2+C3+1 1+C3+0+C3+1 1+C3+4+C3+1 1+C3+3+C3+1 1+C3+2+C3+1 2+C3+4+C3+2 2+C3+3+C3+2 2+C3+4+C3+2 E IE 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 54" Height Head & Sill 1+C2+0+C2+1 1+C2+0+02+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+2+C3+1 1+C3+2+C3+1 1+C3+0+C3+1 1+C3+3+C3+1 1+C3+3+C3+1 1+C4+0+C4+1 1+C3+4+C3+1 1+C3+4+C3+1 2+C3+3+C3+2 2+C3+4+C3+2 2+C4+3+C4+2 2+C4+4+CA+2 1+C2+0+C2+1 1+C2+0+C2+1 1+(2+0+(2+1 1+C2+0+C2+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+2+C3+1 1+C3+1+C3+1 1+C3+0+C3+1 1+C3+3+C3+1 1+C3+2+C3+1 1+C4+0+C4+1 1+C3+4+C3+1 1+C3+3+C3+1 1+C3+2+C3+1 2+C3+4+C3+2 2+C4+3+C4+2 2+C4+4+C4+2 n E I= 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 63" Height Head & Sill 1+C2+0+C2+1 1+C22+0+C2+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+2+C3+1 1+C3+2+C3+1 1+C4+0+C4+1 1+C3+3+C3+1 1+C4+3+C4+1 1+C4+0+04+1 1+C4+4+04+1 1+C4+4+C4+1 2+C4+3+C4+2 2+C4+4+C4+2 2+C4+3+C4+2 2+C4+4+C4+2 1+C2+0+C2+1 1+C2+0+C2+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+2+C3+1 1+C3+1+C3+1 1+C4+0+04+1 1+C3+3+C3+1 1+C4+2+C4+1 1+C4+0+04+1 1+C4+4+C4+1 1+C4+3+C4+1 1+C4+2+C4+1 2+C4+4+C4+2 2+C4+3+C4+2 2+C4+4+C4+2 NOTES:SEE TABLE 15 FOR DESIGN PRESSURE 1) FRAME DIMENSIONS ARE BUCK WIDTH AND BUCKHEIGHT (SEE SHEETS 3-4). SASH SIZE IS AS PER THE FIGURES ON SHEETS 6-8. 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE. 3) SEE SHEET 9 FOR A GUIDE TO USING THESE TABLES. 4)"1/4-1/2-1/4' AND "1/3-1/3-1/3" INDICATE THAT THOSE STANDARD SASH CONFIGURATIONS FALL WITHIN THE SASH WIDTH RANGE IN THE ADJACENT COLUMN. "CUSTOM" INDICATES THAT NO STANDARD SASH CONFIGURATIONS FALL WITHIN THE RANGE. li 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4' 4 4 4 4 4 GS LU > C >ic 8 g 02 Z & 20 1- 1 -Z CN UD LL r-- - X 06 00 0 45 a z PRODUCT REAGSED as complying with the Mo,ME Building Code .Accel>tailee No 16=07 /4 /7 EK'#71)»t«5:P,90,7 M inhiplide Prodt:ct: Co*:**<lj 1 0 1 2 LL 0 12 UJ 0 8 CD 1 .r CD DO (0 LU CO 1- 1- Z D a 0 I 0 Z <C 811!i A. 6 Vi] [& A. LYNN MILLER, P.E. P.E.#58705 L0 E 0 CO 0 CO 0 A8 UN,DJO LU _1 -1 0 -J <C Z 0 N 0 I ·0530 <C AGB r- 9 0 L0 LO I ON SMO 00 IL 0 LO r- 48@ VS CO Z -3133T 0 L0 L0 02 I sauas 8 E j 8 TABLE 27: Glass Types 14 - 16 Reinf. Level R4 35-1/4" 38" 45-1/8" 47-3/4" 52-1/8" 60" 75" 96" 120" 140" 35-1/4" 38" 45-1/8" 47-3/4" 52-1/8" 60" 75" 96" 120" 140" Sash Conliguration %-%-% %3-%-%3 %-%-%4 %-%-* %-%-% %-%-% Custom %-%-% %-%-1% Custom KIX-% *-%-% Custom %-%-% %-%-% Custom %-%-34 %-%-% %-%-% %-%-% Custom %-%-% %-%-% %-1%-% A-%-% %-%-% %-A-% Custom %-%-%4 %-%-34 Custom 1%-%-% %-%-* Custom 34-*-* %-%-% Custom %-%-% %-%-% %-1%-% %-%-% Custom GLASS TYPES 10-12 & 14-16MAY NOT BE USED WITH J-CHANNELOR INTEGRAL I FIN FRAMES Sash Width Range (in) 11.391 -11.391 12.308 - 12.308 11.391 -13.397 13.398 - 14.683 11.391 - 12.297 12.298 - 15.558 11.391 - 12.016 12.017 - 13.397 13.398 - 17.016 11.391 -13.397 13,398- 15.360 15.361 - 19.641 11.391 - 13.397 13.398 -19.110 19.111 -24.641 17.641 - 19.397 19.398 - 24.360 24.361 -31.641 29.641 -32.515 32.516 -39.641 ** -39.641 11.391 -11.391 12.308 - 12.308 11.391 - 13.397 13.398 - 14.683 11.391 -12.297 12.298 - 15.558 11.391 -12.016 12.017 - 13.397 13.398 - 17.016 11.391 -13.397 13.398 - 15.360 15.361 - 19.641 11.391 -13.397 13.398 -19.110 19.111 -24.641 17.641 - 19.397 19.398 -24.360 24.361 -31.641 29.641 - 32.515 32.516 -39.641 ** - 39.641 24" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+2+C2+1 1+C2+2+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 2+C2+2+C2+2 2+C2+3+C2+2 2+C2+3+C2+2 2+C2+3+C2+2 0 E IE 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 30" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+(2+0+(2+1 1+22+0+(2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+2+C2+1 1+C2+2+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C3+0+C3+1 1+C2+3+C2+1 1+C2+3+C2+1 2+C2+3+C2+2 2+C2+3+C2+2 2+C2+3+C2+2 2+C2+3+C2+2 n E 2 2 2 WINDOW WIDTH - 60.72 " MIN. SASH SIZE = 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 36" Height n Head & Sill @ 48" Height Head & Sill Anchor Group A Not Allowed Anchor Group B 1+C2+0+C2+1 3 1+C2+0+C2+1 1+C2+0+C2+1 3 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C2+2+C2+1 1+C2+2+C2+1 1+C3+0+C3+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C3+0+C3+1 1+C2+4+C2+1 1+C2+4+C2+1 2+C2+3+C2+2 2+C2+4+C2+2 2+C2+3+C2+2 2+C2+4+C2+2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1+C3+0+(3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+2+C3+1 1+C3+2+C3+1 1+CA+0+C4+1 1+03+3+C3+1 1+C3+3+C3+1 1+CA+0+C4+1 1+C3+4+C3+1 1+C4+4+C4+1 2+C4+3+C4+2 2+C4+4+C4+2 2+C4+4+C4+2 2+C4+4+C4+2 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 54" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C4+0+C4+1 1+C4+0+C4+1 1+C4+0+C4+1 1+C3+2+C3+1 1+C3+2+C3+1 1+C4+0+C4+1 1+C4+3+C4+1 1+C4+3+C4+1 1+C5+0+C5+1 1+C4+4+C4+1 1+C4+4+C4+1 2+C4+3+C4+2 2+C4+4+C4+2 2+C4+4+C4+2 2+C4+4+C4+2 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Anchor Quantities for XOX Windows 4 63" Height Head & Sill 1+C2+0+C2+1 1+C3+0+C3+1 1+C4+0+C4+1 1+C3+0+C3+1 1+C4+0+C4+1 1+C3+0+C3+1 1+C4+0+C4+1 1+C4+0+C4+1 1+CA+0+C4+1 1+CA+2+C4+1 1+CA+2+C4+1 1+C5+0+C5+1 1+C4+3+C4+1 1+(4+3+(4+1 1+C5+0+(5+1 1+C4+4+C4+1 1+C4+3+C4+1 1+C4+2+CA+1 2+C4+4+CA+2 2+C4+3+C4+2 2+04+3+(4+2 n E 4 24" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+(2+2+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+2+C2+1 1+C2+2+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 2+C2+3+C2+2 2+C2+2+C2+2 2+C2+3+C2+2 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C2+0+C2+1 1+C2+2+C2+1 1+C2+2+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C2+2+C2+1 2+C2+3+C2+2 2+C2+2+C2+2 2+C2+3+C2+2 n E 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 30" Height Head & Sill 1+C2+0+C2+1 1+C2+0+CQ+1 1+C2+0+C2+1 1+02+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+2+C2+1 1+C2+2+C2+1 1+C2+0+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 1+CS+0+(3+1 1+C2+3+C2+1 1+C2+3+C2+1 2+C2+2+C2+2 2+C2+3+C2+2 2+C2+3+C2+2 2+C2+3+C2+2 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+2+C2+1 1+02+1+02+1 1+C2+0+C2+1 1+C2+2+C2+1 1+C2+2+02+1 1+C3+0+C3+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 2+C2+3+C2+2 2+C2+3+C2+2 2+C2+3+C2+2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 36" Height Head & Sill n E 48" Height Head & Sill Anchor Group C 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C2+2+C2+1 1+C2+2+C2+1 1+C3+0+C3+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C3+0+C3+1 1+C2+3+C2+1 1+C2+3+C2+1 2+C2+2+C2+2 2+C2+3+C2+2 2+C2+3+C2+2 2+C2+3+C2+2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1+C2+0+C2+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+2+C3+1 1+C3+2+C3+1 1+C4+0+C4+1 1+C3+3+C3+1 1+C3+3+C3+1 1+C4+0+C4+1 1+C3+4+C3+1 1+C4+4+C4+1 2+C4+3+C4+2 2+C4+4+C4+2 2+C4+3+C4+2 2+C4+4+C4+2 Anchor Group D 1+C2+0+C2+1 3 1+C2+0+C2+1 1+C2+0+C2+1 3 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C2+0+C2+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C2+2+C2+1 1+C2+1+C2+1 1+C3+0+C3+1 1+C2+3+C2+1 1+C2+2+C2+1 1+C3+0+C3+1 1+C2+3+C2+1 1+C2+3+C2+1 1+C2+2+C2+1 2+C2+3+C2+2 2+C2+3+C2+2 2+C2+3+C2+2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+2+C3+1 1+C3+1+C3+1 1+(4+0+(4+1 1+C3+3+C3+1 1+C3+2+C3+1 1+C4+0+C4+1 1+C3+4+C3+1 1+C4+3+C4+1 1+C4+2+C4+1 2+C4+4+C4+2 2+C4+3+C4+2 2+C4+4+C4+2 E 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 54" Height Head & Sill 1+C2+0+C2+1 1+C2+0+C2+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+03+0+03+1 1+CA+0+C4+1 1+C4+0+C4+1 1+04+0+CA+1 1+C3+2+C3+1 1+03+2+C3+1 1+C4+0+C4+1 1+C4+3+C4+1 1+C4+3+C4+1 1+CS+0+C5+1 1+C4+4+04+1 1+C¢+4+C¢+1 2+C4+3+C4+2 2+C4+4+C4+2 2+C4+3+C4+2 2+C4+4+C4+2 1+C2+0+(2+1 1+C2+0+C2+1 1+(3+0+(3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C3+0+C3+1 1+C4+0+C4+1 1+CA+0+C4+1 1+CA+0+CA+1 1+C3+2+C3+1 1+C3+1+C3+1 1+(4+0+C4+1 1+CA+3+C4+1 1+C4+2+CA+1 1+CS+0+CS+1 1+CA+4+C4+1 1+04+3+(4+1 1+(4+2+(4+1 2+04+4+C4+2 2+C4+3+C4+2 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 63" Height Head & Sill 1+C2+0+C2+1 1+C3+0+C3+1 1+C4+0+C4+1 1+C3+0+C3+1 1+C4+0+C4+1 1+C3+0+C3+1 1+C4+0+C4+1 1+C4+0+C4+1 1+C4+0+C4+1 1+C4+2+C4+1 1+C4+2+C4+1 1+C5+0+C5+1 1+C4+3+C4+1 1+C4+3+C4+1 1+C5+0+C5+1 1+C4+4+C4+1 1+C4+3+C4+1 1+C4+2+C4+1 2+C4+3+C4+2 2+C4+3+C4+2 2+C4+3+C4+2 1+C2+0+C2+1 1+C3+0+C3+1 1+C4+0+C4+1 1+C3+0+C3+1 1+C4+0+C4+1 1+C3+0+C3+1 1+C4+0+C4+1 1+C4+0+C4+1 1+C4+0+C4+1 1+C4+2+C4+1 1+C4+1+C4+1 1+C5+0+C5+1 1+C4+3+C4+1 1+C4+2+C4+1 1+C5+0+C5+1 1+C4+3+C4+1 1+C4+3+C4+1 1+C4+2+C4+1 2+C4+3+C4+2 2+C4+2+C4+2 4 2+C4+4+C4+2 4 2+C4+3+C4+2 4 SEE TABLE 16 FOR DESIGN PRESSURENOTES: 1) FRAME DIMENSIONS ARE BUCK WIDTH AND BUCK HEIGHT (SEE SHEETS 3-4). SASH SIZE IS AS PER THE FIGURES ON SHEETS 6-8. 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE. 3) SEE SHEET 9 FOR A GUIDE TO USING THESE TABLES. 4) "1/4-1/2-1/4" AND "1/3-1/3-1/3" INDICATE THAT THOSE STANDARD SASH CONFIGURATIONS FALL WITHIN THE SASH WIDTH RANGE IN THE ADJACENT COLUMN. "CUSTOM" INDICATES THAT NO STANDARD SASH CONFIGURATIONS FALL WITHIN THE RANGE. n E 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 FS 111 2 1 1-0 02 00 NE OW 1 -1 N AS 0 LL 05 m0 45 0- z ML- 1 r¥ PRODUCT REVISED as cow,plyi,g with the Flosid@ Bciad.1% CodeAcceptance No /6.0724· /7 **,(3,2-**SE=@*0 E 32 LL 0 12 0 Lf) E E 0 3/D(] 31#11 LU 01 1.- 1- Z < D a CE 0 I 0 Z 2 0 0 XB UMOU C>sa(] A. LYNN'10!ILLER, P.E. P.E.#58705 -1 LU 0 Z 0 N 0 I <C -ASM 9 0 r- L0 Lr) I ON SMC 00 LL 0 CO Z a/DOS 0 LO LO 02 I sayas TABLE 28: # 1 2 3 4 13 14 15 16 17 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 37 38 39 40 41 42 43 44 45 46 47 48 72 74 75 80 81 82 83 84 85 86 87 part # 620121 620122 620123 620124 620172 620131 620158 620129 620166 620156 620144 620150 620151 620152 620153 620154 620155 710X114PPA 61644 61719 78)612PPA 71669SP 720210 720187 720197 720199 720196 720200 76X34PPA 7612FPTX 720204 620135 71684/5 61011 61012 47042W 47041W/CKGLB 7CASPM 61816C48 61635/61614 Bill of Material Description Frame Head, Sill and Jambs - J-Channel Frame Head, Sill and Jambs - Flange Frame Head, Sill and Jambs - Fin Frame Head, Sill and Jambs - Equal Leg Anti-Lift Insert / Tam Cover Fixed Meeting Rail Track Insert Sash Rail (Sides, Top & Bottom) Monolail Pull Rail Interlock Pull Rail Interlock Cover Light Sash Reinbrcement Standard Sash Reinforcement HD Sash Reinforcement Standard Meeting Rail Reinbrcement HD Meeting Rail Reinbrcement H.D. Horiz. Roller Meeting Rail Reinforcement #10 x 1-1/4" PH. PH SDS (Monorail Screw) Weatherstrip,.187" x .270" Fin Pile Weatherstrip,.187" x .220" Poly Pile #8 x 1" Ph. PH SDS (Interlock Mounting Screw) #8 x 3-1/2" Ph. PH SMS (Fixed Meeting Rail Screw) Meeting Rail Screw Support Plate Weep Hole Cover Installation Screw Hole Plug Auto Lock Sweep Lock Auto Lock Cover Assembly #6 x 1-1/8" Ph. FH SDS (Auto and Sweep Lock Screw) Auto and Sweep Lock Keeper #6 x 3/4" PH. PH SDS (Keeper Screw) #6 x 1/2" FPH Tek (Reinbrcement Screw) Leadstile Top Comer Key Leadstile Bottom Comer Key Lockstile Top Comer Key Lockstile Bottom Comer Key Wheel Lami. I.G. Bead Backbedding, GE 7700 or Dow 791 Setting Block (7/8" x 2" x 1/8"), 85 +/- 5 durD. Roll-formed Screen Extruded Screen Frame Extruded Screen Spreader Bar Screen Comer Key with Pull Ring Screen Comer Key No Pull Ring Tension Spring Screen Cloth .140" Screen Spline (Machine/Hand Rolled) Material PVC PVC PVC PVC PVC PVC 6063 1'6 Al PVC PVC 6063 T6 Al 6063 TB Al 6005 T5 Al 6005 T5 Al SS SS Nylon Nylon Nylon Nylon Nylon PVC 6063 T6 Al 6063 T6 Al 6063 T6 Al 6005 T5 Al 410 SS 410 SS 410 SS 6063 T5 Al PVC PVC C Steel Cast Znc Cast Zinc SS Cast Zinc Silicone EPDM Alum Alum Alum PVC PVC SS Fiberglass Vinyl NOTES: 1) ITEMS # 5-12,18, 35, 36,49-71 & 73 ARE NOT USED AND ARE NOT PART OF THIS APPROVAL. 2) PVC BY ROYAL WINDOW AND DOOR PROFILES, LTD., TO BE LABELED FOR AAMA EXTRUDER CODE. 3.500" ./ .062" =r--ru--lf-11-C '625" -E1375. lu 0 J-CHANNEL FRAME HEAD, SILL & JAMBS -T 3.500" 2.445" [_1] .625" FLANGE FRAME 2-1 0 HEAD, SIU & JAMBS - 1.872" --- 1.507" 4 1 »= .065" ---- .772" L ANTI-LIFT INSERT& TRIM COVER g 5-4 C] 3.500" .. -71011 FIN FRAME HEAD, SIU & JAMBS |- 1.641" -|41-7 11 1.437" a - 1.630" - 1.020" 1 #1 1.375" Sh@ 1 -r .060" ---1-· 4-1 1.000" 1-• 1.231" k·- (Ipj FIXED - TRACK L) MEETING RAIL 5 INSERT ) SASH RAIL 3.500" = - 062" //Y 2373--blLF -lfl EQUAL LEG FRAME HEAD, SILL & JAMBS -- 2.1°I i-1 IT 2.176"11 & tu 72%.471"590" -050. 3 +.070" - - LIFT RAIL -LIFT RAIL 119)(20) - INTERLOCK -INTERLOCK COVER -316'.070"1 -141111- .864" --175" |]f„ .300" -- -» 1{.060" 1 .715" T .035" _0 .025" «»-34 1.185"»f .060" STANDARD /-1 LAMI IG /Ch EXTRUDED REINFORCEMENTLIGHT SASH LE) BEADING CY SCREEN FRAME REINFORCEMENT SASHROLLED(21h SCREEN FRAME \_/ -_.070" --11----4 1.182'- 1·184" |--0 -T 1-40 -.070" | | 1.036"1.041' FT810" I --f-,070" 791" 1 1 -L 1 --|j .130" f- --11--.150" -I-1 1.331" i-- _+ 1.340"- - STANDARD -HD MEETING HD SASHREINFORCEMENT (31) MEETING RAIL (*RAIL REINFORCEMENT REINFORCEMENT 4 6114 86 ® 2.445" --J 2.445" A LYNN MILL-fER, RE. P'E # 58706 1070 TECHNOLOGY DRIVE N. VENICE, FL 34275 P.O. BOX 1529 NOKOMIS, FL 34274 CERL OF AUTH.#29296 - .280" 1 IT 1 L.074" 3 -fl-]]».094" IL -b- ·164" _ -» 1.340" 1-- HD HR MEETING RAIL (19 MONORAIL REINFORCEMENT Revised By: Revised Ely: 1.375' 1 Date: Date: Revision: Revision: Description: WINDOW EXTRUSIONS & BOM Iltle: HORIZONTAL ROLLER - LM Series/Model: HR-5510 Scale: NTS Sheet. 17 OF 18 2.445" PRODUCT REVISED as c=plying with th* 4-k*h Bunding CodeAccepla©e No /6-07/4. 17 Mitff"deP=jud C»'1511 Drown By: J ROSOWSKI Drawing No. MD-HR5510-01 Date: 05/15/15 Rev: A 86 17 44 MITERED FRAME WITH INTERIOR AND EXTERIOR FRAME WELDS 76 87 72 X4 48 1 3* 14 82 OPT. »\ X4 4 9 80 OR SCREEN ASSEMBLY DETAILS Y ) OR 84 EXTERIOR FRAME 0 ASSEMBL,< DETAILSNOTES: 1) GLASS AND SOME PARTS/OPTIONS NOT SHOWN ON DRAWING FOR CLARITY. 2) J-CHANNEL FRAME SHOWN, PART # 1. OTHER FRAME TYPES APPLY. 3) FOR REINFORCEMENT TYPES, SEE DETAILS ON SHEETS 6-8. SASH ASSEMBLY DETAILS EXTERIOR 0 47 MITERED FRAME WITH INTERIOR AND EXTERIOR FRAME WELDS 19 ATTACHED TO SASH RAIL ATTACHED TO 30 FRAMEJAMB 37 40 OPT. AUTO LOCK 2 /-- ATTACHED TO -/ f FRAME JAMB r-(2) S%»/ OPT. SWEEP LOCK A. LYNN MILLER,:PLE P.E.#'58705 2 Revised By: Revised By: ® 11-11 ® L__1 TABLE 21: 103 104 Part # Egress Lock Bill of Material 7MC7024 73340 72015 720214 220217-221 71024X12HFX 78X1 FPAX 78X75FPTX EGRESS LOCK DETAILS (NOT TO SCALE 106 101 107 ® E- Date: Dote: # 100 101 102 103 104 105 106 107 ATTACHED TO FRAME JAMB Revision: Description: EXPLODED WINDOW VIEW Title: HORIZONTAL ROLLER - LM Series/Model: HR-5510 100 Revision: SCO/e: NTS Description Multi-Point Lock Operator Operator mounting Plate Multipoint Lock Keeper Multipoint Lock Guide lie Bar (Length Varies) #10 x 1/2' HH MS #8 x 1" Ph. FH SMS #8 x 3/4' Ph. FH SDS Sheet: 18 OF 18 MateMal Cast Zinc Steel Aluminum Nylon Stainless Steel Stainless Steel Stainless Steel Stainless Steel PRODUCT REVISED as Cemplyiss withB* 0100&4* RN#CO© 16.011437Acceptance No Expiration Date 2520 splkbALIOpi« Mitini.de pr(*349. C»tLj 1070 TECHNOLOGY DRIVE N. VENICE, FL 34275 (941)-480-1600 ® CERT. OF AUTH. #29296 Drawn By: J ROSOWSKI Drawing No. MD-HR5510-01 Date: 05/15/15 Rev A