HomeMy WebLinkAboutProduct Approval Florida Building Code Online ' �'' +I 3/14/17, 11:42 Al
let
Ai ssa
SCIS Home log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links '*Search
0'4�'Product!Approval
USER:Public User
product Approval Menu>Product or Appli6tion Search>Aonlicati n List>Application Detail
FL# FL16660-R6
Application Type Revision
Code'_Verston.. 2014
Application Status Approved
Comments
� 1
Archived
Product Manufacturer Haas Door Company
Address/Phone/Email 320 Sycamore St.
Wauseon,OH 43567
(419)337-9900 Ext 243
mschweltzer@haasdoor.com
Authorized Signature Mark Schweitzer
mschweitzer@haasdooscom _
,i
Technical Representative
Address/Phone/Email
Quality Assurance Representative j
Address/Phone/Email
Category Exterior Doors
Subcategory Sectional Exterior Door Assemblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer,.
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who,developed John E. Scates
the Evaluation Report
Florida License PE-51737
Quality Assurance Entity Architectural Testing, Inc.
Quality Assurance Contract Expiration Date 12/31/2018
Validated By Kurt Dietrich PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL1666 _R6_C0j_Qaa_2f_lGtd scat's_�;.pdf
Referenced Standard and Yearof Standard)) standard ( Year
ANSI/DASMA 108 2012
ANSI/DASMA 115 2012
i
t
https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=w...DgsHepng4Vo2fS8e4gonT4z%2fE8EmDgOZ8sFKfxB%2bhSeMputwA%3d%3d Pagel o
Florida Building Code Online 3/14/17, 10:53 AA
�R2571, R2572, R2580, 112581,
R25112 I
Limits of Use- Installation Instructions
Approved for use in HVHZ: No F1J.666n R6,Tr- WL2000-Oi94-24-77L.-RevE_s,pdf
Approved for use outside HVHZ:Yes Verified 13y:John E.Scates 51737
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure:+23.9/-26.7 . Evaluation Reports
Other:Glazing is an available option for all the Pan Series FL16660 R6 AE . SIRe tt r6a_s.ndf
product listed but it does not meet the Impact resistant Created by Independent Third Party: Yes
requirement for windborne debris regions.
- p
16660.11 {11. PAN 02011,02015,02410, PAN Series sectional; an type garage door 16'2" wide
1 R2410,C2411,C2415, C2460, j
R2460,C2461,R2461,C2471,
R2471,C2472,R2472,C2480,
I R2480,C2481, R2481,C2482,
f R2482,02511, R2560, R2561,
112571, 112572, 112580, 112581,
R2582
Limits of Use Installation Instructions
I --`--- -_
C
Approved for use in HVHZ:No F 1 0 R6_L-I_WL 2000-0194_31-35-RevD-S.Pdf
I Approved for use outside HVHZ:Yes Verified By:John E.R Scates 51737
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure:-+31.3/-34.9 Evaluation Report's
Other: FL.16660R6_�F v iRe t_r6a_�d€
Created by Independent Third PartyYes
116660.12 12. PAN C2011,C2015,C2410, PAN Series sectional pan type garage door 18'2"wide
R2410,C2411,02415,02460,
82460, C2461, R2461,C2471, i
iR2471,C2472, R2472,C2480,
82480,C2481, R2481,C2482,
R2482, C2511, R2560,R2561,
82571, R2572, 82580,R2581,
!
IR2582
Limits of Use - Installation Instructions
Approved for use in HVHZ: No Fd1 60_B6_11_LVL-2000-0218-24-271_RevF_s.pdf
Approved for use outside HVHZ:Yes Verified By:John'E. Scates 51737
Impact Resistant:No Created by Independent Third Party: Yes
Design Pressure: +23.9/-26.7 Evaluation Reports
Cather: Glazing is an available option for all the Pan Series FL16660_R6_AE.:-vai nt_r a s.radf
product listed but it does not meet the impact resistant Created by Independent Third Party: Yes
requirement for windborne debris regions.
16660.13
113* HT 600,700,2000;800,&900 HT Series sectionaljsandwich type garage door 9'2"wide -
Series
' laant#s of Use.__._._____.. Installation%nskre>!ctions�_._...__-__--________.___. _
Approved for use in HVHZ:No FL1666 _R6I1 JWL-0600-0110-08-41-46-RevC_spdf
Approved for use outside HVHZ:Yes Verified By:John E.Scates 51737
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: +41.1/-46.4 I Evaluation Reports
Other: ki FL16660_R6 AE,EvaiRent_ 6r a s.gdf
Created by Independent Third Party: Yes
16660.14 14. HT 600,700,2000,800,&900 HT Series sectional sandwich type garage door 9'2"wide
Series I
Limits of Use Installation%nstructians
Approved for use in HVHZ: No FLIF �zQ_R6_I3 VIL-06 0 0110-08-x+1-461.RevE;_.c:d€
Approved for use outside HVHZ:Yes Verified By: John E.Scates 51737
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:+41.1/-46.4 Evaluation Reports
L
Other:Glazing is an available option for the 600, 700, 2000 F _6660_R6 P_E_EvalRent_r6a_s,p f
&800 Series product only.It does meet the impact resistant Created by Independent Third Party: Yes
requirement for windborne debris regions.Glazing is not an 1
available option for the 900 Series product.
r16660.1-5 15. HT 600, 700, 2000,800,&900 HT Series sectional sandwich type garage door 16'2"wide
Series i
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=w...DgsHepng4%2fS6e4gonT4z%2fEBEmOgQZ9sFKfxBO/o2bhScMputwA%3d%3d Page 4 c
I
1 2 3 4 5 6 7 8
Door Width 16'-2"Shown NOTE: Track configuration above
the door opening does not affect
F See chart below for other the wind load rating of the door. F
Top Bracket door widths
DETAIL A(sheet 2 of 3) 7(sheet2of3)
Bracket
9
_••
do.
00
v
1
a
• e e e
E- • -- -- - - - E
Jamb Bracket
Detail F(sheet 2 of 3)
Door Height Slide Lock or Lock Bars
7'-0"Shown Detail G(sheet 2 of 3) 1
Manual door locks are
See chart required unless an automatic
operator is in
below for other 3"
door heights z"+/ 3"
D 38Z"+/_3" D
22Z"+/-3"
� e o
End Hinges Intermediate Hinge 4"+/-3"
Detail B sheet 2 of 3) Detail D sheet 2 of 3
Bottom Bracket Strut 9 Strut Attachment OZ"+/-3"
c Detail C(sheet 2 of 3) Detail E(sheet 2 of 3) C
This product has been evaluated per ANSI/DASMA 108-05 for static air pressure. Jamb bracket quantities shown are for use
with grade 2 or better southern pine jambs.
Model Number
be
PAN 02460 s 82460 SERIES Supporting structural elements are
designed by a registered professionalal engineer
PAN 02410882410 SERIFS PAN C2461 a R2461 SERIES for specific wind loads.
PAN C2480 8 82460 SERIES PAN C24716 R2471 SERIES
PAN 02481 8 R2481 SERIES PAN 02472 8 R2472 SERIES Door Total#of Total#Of Struts Jamb Brick NOTICE:
Height Sections rSide These drawings are a
PANC24828R2482SERIES PANR2560SERIES 6'-0' 4 4 5 supplement to the installation
B PAN 82580 SERIES PAN R2561 SERIES PAN C2000 SERIES instructions for a standard door B
PAN R2581 SERIES PAN R2571 SERIES PAN C2400 SERIES G-3" 4 4 6 and only covers those
PAN 82582 SERIES PAN 82572 SERIES PAN 02500 SERIES 6'-6' 4 4 6 procedures that vary from
tandard door installation. If John E Scates, P.E.
Desi n Pressures Intertnedlete Stiles internedtate Stiles Intermediate Stiles Im et 6'-9' 4 4 6 these specific procedures are 3121 Fair ate Drive
Doer Width End Stile 9
+ - s /Hinges /Hinges /Hinges Resstant T-0' 4 4 6 not followed, the door may not Carrollton, Texas 75007
12'-2' 41.5 -06.3 Single 52 512 5@ NO T-6' 5 5 7 perform as designed. Florida P.E. # 51737
14'-2' 35.7 -39.8 Single 6/3 5/2 7/3 NO 7--9" 5 1 5 7 TX P.E. #56308/F2203
16'-2' 31.3 -34.9 Single 7/3 7/3 7/3 NO 8'-0' 5 1 , 5 7 Professional Engineer seal provided only for
18'-2' 24.7 -27.6 Single 7/3 7/3 7/3 NO Maximum section height is 21 in. verification of wind load construction details.
20'-2" 20.1 -22A Single 9/5 9/5 11/5 NO Maximum door height is 16 ft. DESCRIPTION:
This product is designed and sold by PSF. The AHJ or Engineer of Record is responsible for determining the Doors taller than 8'-0" will be provided with v 1C2•PASECTIO ALDORIES WIND LOAD
SEL7IDNALDOOR
A PSF required for any given site. commercial full angle track having brackets ,,,� 8 1 DESIGNPRESSURE+313/-349PSF A
spaced at 12 inches. -
aellWua EO_W42000-0194-31-35 I EIRET:1 OF 3 fiEY.
M11— UTEDIL• 2nn4 IMVMIR. MVS
am
M CWPW U144 NIODEL(S): See Sheet 3
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
FASTENER TO CONTINUE
F PAST HEADER F
o o
0
E _MODEL NUMBERSe
— — — -- E
o o
MODEL NUMBERS AVAILABLE OPENING 2 X 6GRADE 2 OR BETTER SOUTHERN
HEIGHT PINE JAMBS.
PAN C2000 SERIES o SEE CHART FOR WOOD JAMB ATTACHMENT o
PAN C2400 SERIES TO STRUCTURE.
PAN C2500 SERIES
PAN C2410&R2410 SERIES MAXIMUM ON
D PAN C2460&R2460 SERIES CENTER SPACING D
PAN C2461&R2461 SERIES
PAN C2471&R2471 SERIES FIRST FASTENER 4'to 10°
PAN C2472&R2472 SERIES ABOVE THE FLOOR OPENING
PAN C2480&R2480 SERIES WIDTH
PAN C2481&R2481 SERIES
PAN C2482&R2482 SERIES
PAN R2560 SERIES
C Mnimum Minimum Minimum Maximum AllowablePAN R2561 SERIES C
Jamb Material Fastener Type Embedment Edge on Center on Center Tension
Otstanra spacing Spacing Load
PAN R2571 SERIES
Min.20M PSI Concrete Tepcon 1/4"w/1'OD washer 1.75' 2.50' 4.00' 21' 463 per Dade 12-0818-08
PAN R2572 SERIES Min.3000 PSI concrete Tapcon 1/4'w/1'OD washer 1.75' 2.50' 4.00' 24' 508 per Dade 12-0816-06
PAN R2580 SERIES Min.4000 PSI Concrete Tapconl/4'w/t'OD—her 1.75' 2.50' 4.0(r 1' 538 per Dade 12-08184)8
PAN R2561 SERIES Southern Pine 5116'lag WI 11W OD washer 1.50' 1.50' 1.50' 24' 577 perMS-1619
Sprue Pine Fir 5/16'Lag w/1 U8'OD washer 1.50' 1.67 1.50' 18' 385 per MS-161a
PAN R2582 SERIES
NOTE:2X6 mounted to the wall must be Southern Pine Grade 2 or better.
B B
John E Scates, P.E.
3121 Fairgate Drive
Carrollton, Texas 75007
Florida P.E. # 51737
TX P.E. #56308/F2203
Professional Engineer seal provided only for
verification of wind load construction details.
DESCRIPTION:
16 2'PAN 2080 SERIES WIND LOAD
v SECTIONALDOOR
A DESIGN PRESSURE+313/-34.9 PSF A
DMIND S0.:WL-2000-0194-31-35 I SHEET:3 OF 3 M.
xi16 obw c
UTE DSC 2!7/14 DUWN ST• MVS
e c"' hind m' MODEL(S): See Sheet 3
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
END STILES 23" 23„
.055 Galvanized Steel
Manufactured by Haas Door Co. 4 FIPUSH
D HINGE SCREW 4 INTERMEDIATE STILE
F PUSH NUT Go Galvanized Steel " X 3/4" Hex Washer Head .055 Galvanized Steel F
O Manufactured by Haas Door Co.
0 7/16" TEK SCREW Drilling (3 per Bottom Bracket) "
See DETAIL K for push nut1/4" X 3/4" Hex Washer Head
placement. Self Drilling (6 per Hinge) BOTTOM BRACKET o®o
ADJUSTABLE TOP FIXTURE qW
13 Go Galvanized Steel INTERMEDIATE HINGE
NOTE: This screw should 18 or 14 Ga Galvanized Steel
E Ga be located below the prepunchedPUSH NUT o 0
0 TEK SCREW hole and go through the hinge, See DETAIL K for push nut
1/4" X 3/4" Hex Washer Head �— P TEK SCREW
Self Drilling (4 per Bracket) end stile and skin edge. placement. 1/4" X 3/4" Hex Washer Head
NUT OTTOM SEAL Self Drilling (4 per Hinge)
7/16-
E DETAIL- A - - --- DETAIL-B— - See-DETAIL -for-push—nut DETAIL C_ _ DETAIL E
_--
placement. - - --- - - -- --- --- - _ ..- - - -
3 1/2" x 4" E STRUT
18 Go 50 KSI Galvanized Steel
4� JAMB BRACKET
}` '7� 12 Ga Galvanized Steel 0 0 o SLIDE LOCK or OTHER
0 C 10 10014 L o LOCK MECHANISM (not
32e required with operator) 1
D 0 TEK SCREW 1/4a 32D
O BOLT & NUT o 0 1/4" X 3/4" Hex Washer
(1:E 1/4-20 X 5/8" Carriage Head Self Drilling (4 per DETAIL K ROLLER
X 34Hex Washer
TEK SCREW Slide Lock)
1/4" " Bolt & 1/4-20 Hex Washer
/ / There should be a space of 2'Diameter Nominal
DETAIL E Head Self Drilling (2 per DETAIL F Nut (1 per Jamb Bracket) DETAIL G 1/4" between the roller hub Ten Ball Steel
End & Intermediate Stiles) and the outside edge of the
roller holder which is set by
NOTE: Details on some views omitted for clarity. the push nut.
C C
00 00m 0
FLAG BRACKET
0
NOTE: Door must overlap side
jambs a minimum of 1" on each
side to meet required wind load. 0O BOLT
5/16 X 1 5/8" Lag Bolt
Min. PAN DOOR SECTION Min. (4 per Flag Bracket).
B Of 1" Minimal 25 Go Galvanized Painted Steel Of 1"
B
- BOLT & NUT John E Scates, P.E.
1/4-20 X 5/8" Track Bolt 3121 Fairgate Drive
& 1/4-20 Hex Washer Nut Carrollton, Texas 75007
(2 for Horizontal & 2 for Florida P.E. # 51737
Vertical Track) TX P.E. #56308/F2203
VERTICAL TRACK Professional Engineer seal provided only for
BOLT & WASHER 2 Nominal 13 Ga Galvanized Steel
verification of wind load construction details.
WOOD JAMB E OESCRIP1IOR:
5/16 X 1 5/8" Lag Bolt & 2" The vertical wood jamb fasteners may 162•PAN 20M SERIES WEND LOAD
A O.D. x 7/16" I.D. Flat Washer be counter sunk to provide a flat is SECRONALDOOR
NOTE: Jamb bracket must be in direct mounting surface. See jamb ) 7 i DESIGN PRESSURE+313/-34.9 PSE A
contact with the 2x6 (No drywall allowed). attachment details on sheet 3 for DETAIL H �`'' RRR�IOR®0.°w["z000-0194-3t-35 SHEEc zRP3 9Ev'
attaching jambs to the structure.
kpg RRTEORR: 2M14 11RRNRRT: AiVS
®aWrrea�M4 MODEL(S): See Sheet 3